THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT

Similar documents
High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

Chapter 6.2: space based cosmic ray experiments. A. Zech, Instrumentation in High Energy Astrophysics

Performance of the AMS-02 Electromagnetic Calorimeter in Space

AMS : A Cosmic Ray Observatory

Dark Matter Searches with AMS-02. AMS: Alpha Magnetic Spectrometer

PAMELA: a Satellite Experiment for Antiparticles Measurement in Cosmic Rays

THE AMS RICH COUNTER

Antimatter and DM search in space with AMS Introduction. 2 Cosmology with Cosmic Rays

The AMS-02 Anticoincidence Counter

Dark Matter Particle Explorer: The First Chinese Cosmic Ray and Hard γ-ray Detector in Space

arxiv: v1 [physics.ins-det] 3 Feb 2014

Cosmic Ray Physics with the Alpha Magnetic Spectrometer

Indirect Search for Dark Matter with AMS-02

The space mission PAMELA

New results from the AMS experiment on the International Space Station. Henning Gast RWTH Aachen

Cosmic Ray panorama. Pamela.roma2.infn.it PAMELA (2012) Experimental challenges : e + /p ~ 10-3 e + /e - ~ 10-1

The Alpha Magnetic Spectrometer on the International Space Station

The Latest Results from AMS on the International Space Station

Status of the PAMELA silicon tracker

Justin Vandenbroucke (KIPAC, Stanford / SLAC) for the Fermi LAT collaboration

1 The beginning of Cosmic Ray Physics, the balloons BACKGROUND REJECTION AND DATA ANALYSIS. Aldo Morselli a and Piergiorgio Picozza a.

CALET INSTRUMENT. Calorimeter CGBM

The Ring Imaging Cherenkov detector of the AMS experiment: test beam results with a prototype

The PAMELA Satellite Experiment: An Observatory in Space for Particles, Antiparticles and Nuclei in the Cosmic Rays

Studies of Hadron Calorimeter

SUPPLEMENTARY INFORMATION

PAMELA satellite: fragmentation in the instrument

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

NA62: Ultra-Rare Kaon Decays

GeV to Multi-TeV Cosmic Rays: AMS-02 Status and Future Prospects

arxiv: v1 [astro-ph.he] 2 Jul 2009

PoS(ICRC2017)168. PSD performance and charge reconstruction with DAMPE

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

PEBS - Positron Electron Balloon Spectrometer. Prof. Dr. Stefan Schael I. Physikalisches Institut B RWTH Aachen

Measurements of Heavy Nuclei with the CALET Experiment

Indirect Dark Matter Detection

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

Very High Energy Gamma Ray Astronomy and Cosmic Ray Physics with ARGO-YBJ

The Silicon-Tungsten Tracker of the DAMPE Mission

Experimental review of high-energy e e + and p p spectra

Measurement of absolute energy scale of ECAL of DAMPE with geomagnetic rigidity cutoff

Operation and Performance of the AMS-02 Silicon Tracker

Dual readout with tiles for calorimetry.

DARK MATTER SEARCHES WITH AMS-02 EXPERIMENT

PHY326/426 Dark Matter and the Universe. Dr. Vitaly Kudryavtsev F9b, Tel.:

The AMS-02 Transition Radiation Detector to Search for Dark Matter in Space

Precision measurements of nuclear CR energy spectra and composition with the AMS-02 experiment

Current and Future balloon and space experiments L. Derome (LPSC Grenoble) Tango, May 4-6th, 2009

Antiproton Flux and Antiproton-to-Proton Flux Ratio in Primary Cosmic Rays Measured with AMS on the Space Station

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

The Large Area Telescope on-board of the Fermi Gamma-Ray Space Telescope Mission

PoS(ICRC2017)1076. Studies of Cosmic-Ray Proton Flux with the DAMPE Experiment

Simulation and validation of the ATLAS Tile Calorimeter response

PoS(ICRC2017)775. The performance of DAMPE for γ-ray detection

Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics. PAMELA MissioN 17 December 2010 Prepared by FatiH KAYA

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. First Physics at CMS

The GILDA mission: a new technique for a gamma-ray telescope in the energy range 20 MeV GeV

Examples for experiments that can be done at the T9 beam line

The LHCf experiment at LHC

Correction for PMT temperature dependence of the LHCf calorimeters

Search for Antiparticles in Cosmic Rays in Space and the Earth s Atmosphere. Philip von Doetinchem I. Phys. Inst. B, RWTH Aachen University

Muon reconstruction performance in ATLAS at Run-2

A gas-filled calorimeter for high intensity beam environments

SIMULATION OF THE GAMMA-RAY GALACTIC DISTRIBUTION AS SEEN BY THE AMS-02

Particle Detectors A brief introduction with emphasis on high energy physics applications

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Validation of Geant4 Physics Models Using Collision Data from the LHC

Upgrade of the CMS Forward Calorimetry

AMS Transition Radiation Detector 4-Layer Prototype and Gas System Tests

Precision Cosmic Ray physics with space-born experiment

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

High Energy cosmic-radiation Detection (HERD) Facility onboard China s Space Station

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements

High-energy physics experiments in space

SUPPLEMENTARY INFORMATION

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

MoonCal An electromagnetic calorimeter on the lunar surface. R.Battiston, M.T.Brunetti, F. Cervelli, C.Fidani, F.Pilo

AIRFLY: Measurement of the Air Fluorescence induced by electrons

The new event analysis of the Fermi Large Area Telescope

Introduction to Cosmic Rays Data Analysis Issues. Nicola De Simone INFN and University of Rome Tor Vergata

CALICE Test Beam Data and Hadronic Shower Models

The Fermi Gamma-ray Space Telescope

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

The LHCf experiment at LHC

Theory English (Official)

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

Future prospects for the measurement of direct photons at the LHC

1 Introduction STATUS OF THE GLAST LARGE AREA TELESCOPE. SLAC-PUB December Richard Dubois. Abstract

Performance of the CMS electromagnetic calorimeter during the LHC Run II

The Electromagnetic Calorimeter of the HERA-B Experiment

PANDA Muon System Prototype

Dark Matter Particle Explorer and Its First Results

Calorimetry in particle physics experiments

Physics studies to define the CMS muon detector upgrade for High-Luminosity LHC

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

Transcription:

SF2A 2012 S. Boissier, P. de Laverny, N. Nardetto, R. Samadi, D. Valls-Gabaud and H. Wozniak (eds) THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT M. Vecchi 1, L. Basara 2, G. Bigongiari 3, F. Cervelli 4, G. Chen 5, G. M. Chen 5, H. S. Chen 5, G. Coignet 2, S. Di Falco 4, S. Elles 2, A. Fiasson 2, D. Fougeron 2, G. Gallucci 4, C. Goy 2, M. Incagli 4, R. Kossakowski 2, V. Lepareur 2, Z.H. Li 5, M. Maire 2, M. Paniccia 2, F. Pilo 4, S. Rosier-Lees 2, X.W. Tang 5, C. Vannini 4, J.P. Vialle 2 and H.L. Zhuang 5 Abstract. The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structure, it can also provide the separation of positrons from protons, in the GeV to TeV region. A direct measurement of high energy photons with accurate energy and direction determination can also be provided. Keywords: cosmic rays, calorimeter, high energy photons 1 Introduction The Alpha Magnetic Spectrometer (AMS-02) (see Aguilar et al. (2002)) is a large acceptance particle physics detector, operating onboard the International Space Station (ISS) since May 19th 2011. Since the launch, the detector has collected more than 20 billion events. The main goals of AMS-02 are the search for antimatter and dark matter, and the precise measurements of cosmic rays composition and flux. Moreover, AMS-02 could provide information on gamma rays in the GeV to TeV range. The apparatus is composed of several subdetectors, arranged as in figure 1. Fig. 1. Sketch of the AMS-02 detector. 1 Academia Sinica, 128 Academia Road, Section 2, Nankang, Taipei 115, Taiwan (R.O.C.), and National Central University, No.300, Jhongda Rd., Jhongli City, Taoyuan County 32001, Taiwan (R.O.C.) 2 LAPP, Université de Savoie, CNRS/IN2P3, Annecy-le-Vieux, France 3 Universita degli Studi di Siena, 53100 Siena, Italy 4 Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, 56100 Pisa, Italy 5 Institute of High Energy Physics, CAS, Beijing, 100049, China c Société Française d Astronomie et d Astrophysique (SF2A) 2012

622 SF2A 2012 a Transition Radiation Detector (TRD), equipped with 20 layers, each one using polypropylene/polyethylene as radiator and Xe/Co2 filled proportional wire straw tubes. This detector is used to complement the ECAL in particles identification, up to few hundred GeVs. a Time of Flight (TOF), made of 4 layers of plastic scintillators, providing timing information and the trigger for the experiment. a Magnetic Spectrometer, made of double sided silicon strips, arranged on 9 layers, to measure the sign of the electric charge and the rigidity (momentum/charge) of cosmic rays. The measured quantity is the deflection, i.e. the inverse of the rigidity, for particles in a 0.15 T magnetic field, provided by a permanent magnet. an Anti-Coincidence scintillator Counter (ACC) system surrounds the tracker planes installed within the magnet volume. The ACC system provides the veto signal to the trigger, in order to reject multi-particle events, generated in the interaction of cosmic rays entering the detector through the sides. a Ring Imaging Cherenkov Detector (RICH), to estimate cosmic rays velocity and charge with high accuracy. an electromagnetic calorimeter (ECAL), to measure particles energy, for the electron/hadron separation and for the photon detection. 2 The ECAL detector The ECAL (see Cadoux et al. (2002)) is a lead-scintillating fibers sampling calorimeter, in which particles crossing the active volume produce light collected by photomultipliers (PMTs). The structure has been designed to have a high granularity (one radiation lenght in the longitudinal direction, half a Molière radius in the lateral direction) and to maximize the ratio between radiation and interaction lenght. The resulting composite structure has a lead-fiber-glue volume composition of 1:0.57:0.15 cm 3, as well as an average density of 6.8 g/cm 3. The active part of the detector has a total weight of approximately 638 kg and a total active size of 68.5 68.5 16.7 cm 3 (figure 2). The total depth of the calorimeter is 17 radiation lenghts (0.6 nuclear interaction lengths). Hamamatsu R-7600-00-M4 multianode photomultipliers are the core sensors of the ECAL, while the coupling to fibers is realized by means of plexiglass light guides, that maximize light collection and reduce cross-talk. Optical contact is enhanced by silicone joints, placed on light guides. Each PMT accommodates four 8.9 8.9 mm 2 anodes. Anodes define ECAL granularity: the detector allows for 18 longitudinal and 72 lateral samplings, for a total of 18 72 = 1296 readout units, usually referred to as cells. A 3-D imaging of the shower development has been achieved by alternating 5 superlayers (SL), i.e. 10 layers, with fibers along X axis and 4 SL, i.e. 8 layers with fibers along Y axis. In order to obtain the necessary energy resolution on Minimum Fig. 2. The Electromagnetic Calorimeter honeycomb structure, before the final integration. PMTs are installed on the squared holes. Ionizing Particles (used for detector performance monitoring and equalization) as well as to measure energies up to 1 TeV, the digitization is performed at two different gains: High Gain for low energy measurements, and Low Gain for highest ones, with a conversion factor HG/LG of about 33. Besides the 8 signals from anodes, each PMT last dynode signal is also readout and its information used to build up ECAL standalone trigger. 2.1 Trigger The AMS-02 calorimeter has a key role in photon identification. When a high energy-deposit is recorded in the innermost layers of the calorimeter, a fast signal is generated and processed by the trigger board, which can enable the event acquisition, within 240 ns.

The AMS-02 ECAL 623 In order to discriminate between photons and charged particles, entering the calorimeter from outside its field of view, an angular cut is performed as an additional trigger request. The incident particle direction is evaluated by taking, for each view, the average position of the fired PMTs and a cut at 20 degrees is applied to select particles inside AMS-02 geometrical acceptance. The efficiency for photons is about 20% at 1 GeV and reaches about 99% at 10 GeV, for an average polar orbit rate of 115 Hz (approximately 10% of total AMS-02 rate). 3 Detector performance The full AMS-02 detector has been tested in 2010 using the primary 400 GeV proton beam of the CERN Super Proton Synchrotron (SPS): protons, electrons and positrons beams of energies between 8 and 400 GeV have been used to evaluate the performance of the detector. Before the energy can be reconstructed, several processes have to be taken into account: the first step is to equalize all channels, i.e. to obtain the same response to the same energy deposit. After this step is completed, the deposited energy must be corrected for leakage, in order to recover the fraction of the shower energy not deposited in the calorimeter. After these corrections, deviation from linearity is smaller than 1% in the energy range between 8 and 180 GeV, as can be seen in the left plot of figure 3, while the the energy resolution, is below 2 % at energies higher than 50 GeV, as can be seen in figure 3-right. Fig. 3. Left: Linearity as a function of the energy beam. Right: Energy resolution as a function of the energy beam. Angular resolution is also an important parameter, in particular for gamma ray physics. Under the assumption that a shower initiated by an electron is compatible to a shower initiated by a photon in the ECAL, the angular resolution has been computed using electrons Test Beam data. Figure 4 shows angular resolution as a function of the beam energy: this result is compatible to the one obtained with flight data. 3.1 Detector calibration in space The detector has been operating onboard the ISS since May 2011: a Low Earth Orbit is followed, at about 400 km of altitude from the Earth surface. The thermal environment in space is severe: Sun light as well as the position of the solar panels onboards the ISS can affect the thermal configuration of the instrument, causing performance variations or potential sources of permanent damage. Given the extreme conditions that can be experienced in space, the performance of the detector are continuously monitored. It has been possible to observe that the gain of the PMTs is slightly affected by temperature variations: the ratio between High and Low Gain decreases by 3 10 5 per degree, while the pedestals can increase by half a percent per degree. The identification of MIPs is used to equalize the response of PMTs, the MIP value decreases by about 0.2 percent per degree. All those effects are accounted for in the offline analysis. 4 Particles identification One of the main scientific targets of the AMS-02 detector is to identify the antimatter component out of the most abundant cosmic-ray components. Positrons, for example, must be identified out of a background of

624 SF2A 2012 Angular Resolution (α 68% )[ ] 5 4.5 4 3.5 3 2.5 2 p0 0.3244 ± 0.006781 p1 19.33 ± 0.3319 p2 2.908 ± 0.1033 p1 p2 p0+ + E E 1.5 1 0.5 20 40 60 80 100 120 140 160 180 Beam Energy [GeV] Fig. 4. ECAL angular resolution, evaluated as the angular interval containing 68% of reconstructed angles, a function of energy, for Test Beam data. For electrons, the angle between the tracker track and the shower axis direction is measured. protons, that is 10 3 4 times more abundant than the positrons component. Main sources of background in the antimatter samples comes from charge confusion (i.e. electrons reconstructed as positrons) and from the wrong electron-hadron separation (i.e. protons identified as positrons). In order to identify antimatter particles, all the AMS-02 subdetectors are involved: the Time-Of-Flight system is used to provide the trigger as well as to select down-going particles, the TRD is used to distinguish between protons and leptons, while the magnetic spectrometer is used to identify charge-one particles together with their sign and their rigidity. Electromagnetic and hadronic showers differ in their spatial development and energy distribution in a way that can be distinguished by the calorimeter. The fraction of energy deposited in each ECAL layer allows for an effective separation between hadronic and electromagnetic showers: for hadrons of a given energy, the Fig. 5. Boosted Decision Tree distribution for electrons and positrons (blue distribution), as well as for protons (red distribution) for all energies. distribution of the fraction of energy deposited is essentially flat in each ecal layer, with a sharp peak at low energies for non-interacting hadrons. For electrons and positrons, the fraction of energy deposited is different from layer to layer, and it increases until the shower maximum is reached. Several approaches have been developed within the AMS-02 collaboration, in order to achieve the necessary separation between electrons and protons: Boosted Decision Tree, Neural Network, Likelihood methods and cut based methods. The distribution of the Boosted Decision Tree for electrons (and positrons) and hadrons is shown is figure 5.

The AMS-02 ECAL 625 Those methods, only based on ECAL-related variables, provide a rejection power on protons between 10 2 and 10 3, with a signal efficiency of 90%. Taking into account the match between energy and momentum (as measured by the tracker), the rejection power raises up to about 10 4. If the TRD is also taken into account, the rejection can further improve of about one order of magnitude, while keeping the same signal efficiency. The rejection of those methods have been validated using Test Beam data: at energies higher than 180 GeV, where Test Beam data are only available for protons, Monte Carlo has been used to study their performance. 5 Conclusions The AMS-02 electromagnetic calorimeter design has been described, as well as its performance. The main goal of the detector is to measure the energy of particles up to the TeV: the detector allows for energy linearity better than 1%, and an energy resolution better than 2% at energies higher than 50 GeV. Due to its granularity, ECAL allows for hadron-electron separation: a rejection power of the order of 10 4 is needed to distinguish positrons of the background of protons. This goal is achieved using informations concerning the shower lateral and longitudinal development in the ECAL, as well as the match between energy and momentum (as measured by the magnetic spectrometer). The use of the TRD can further improve the rejection power, up to few hundreds GeV. References Aguilar, M., et al. 2002, Phys. Rept., 366, 331 Cadoux, F., Cervelli, F. et al. 2002, Nucl. Phys. Proc. Suppl., 113, 159