PSA XX - XXXX - X - X - X - X - X
|
|
- Olivia Perkins
- 6 years ago
- Views:
Transcription
1 PNEUMTIC SERVO CTUTOR BORE () COMMUNICTION CRD STROKE () ROD END VLVE ENVIRONMENTL PROTECTION OPTIONS MOUNTING PS XX - XXXX - X - X - X - X - X 3.25 = = = = = = = 8 STNDRD FLOW/3 POSITION = 0 LOW FLOW/3 POSITION = 2 RS232 SERIL = 0 I/O = T CN2.0B = C DeviceNet = D PROFIBUS = P ETHERNET = E SERCOS = S 5/8-8 X.00 MLE = 0M 5/8-8 X.25 MLE = 0ML 5/8-8 X 0.75 FEMLE = 0F 3/4-6 X.25 MLE W/ HEX = 2MH M6X.5-6g X.250" MLE W/ HEX = M6MH NONE = 0 BRONZE ROD BUSHING (NO ROD SEL OR ROD WIPER) = Z ROD BRKE = B VITON SELS = V SS TIE RODS = S IP67 (design) = Base cylder (no mount) = 0 Left (side) Mount = LM Bottom Mount = BM Right (side) Mount = RM Front Trunnion (horizontal wrt valve) = FT Rear Trunnion (horizontal wrt valve) = RT Front Trunnion Vertial (wrt valve) CONSULT FCTORY = FTV Rear Trunnion Vertial (wrt valve) CONSULT FCTORY = RTV Detachable Head Clevis = DHC Detachable Head Eye = DHE CONSULT FCTORY = OTHER MOUNTING OPTIONS SOLD S CCESSORIES Rectangular Flange Front cap = 325RFF Rectangular Flange Back cap = 325RFB Right ngle foot Mount = 325RM tie rod Extensions Front cap = 325EF tie rod Extensions Back cap = 325EB tie rod Extensions Front and Back cap = 325EFB SPECIFICTION NOTES: DRWING PER SME Y4.5N-994 DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ THIRD NGLE PROJECTION NGLE +/-2 DEGREES Property of SUNSTREM INCORPORTED DRWN BY: PPROVED BY: SCLE: N/ 02/22/2 02/22/2 DRWING NUMBER: OF " BORE PS PS325-XX-XXXX
2 Table (unit ). STROKE L L2 L3 L4 P/N = STK = STK = STK = STK/ = STK/ PS XXXX PS XXXX PS XXXX PS325-0-XXXX PS325-2-XXXX PS325-8-XXXX TO TOP OF M6 CIRCULR CONNECTOR L /8-24 UNF - 2B x0.45 MIN SQ SQ WIDTH CROSS FLTS RODn /8-24 UNF - 2B x0.45 MIN L3 L2 L SQ SQ Property of SUNSTREM INCORPORTED 2.65 n /8 CROSS FLTS DETIL SCLE / 3 SEE PGE 4 FOR ROD END OPTIONS SPECIFICTION NOTES: DRWING PER SME Y4.5N-994 DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ THIRD NGLE PROJECTION NGLE +/-2 DEGREES DRWN BY: PPROVED BY: SCLE: :4 3.25" BORE PS DRWING NUMBER: 2 OF 6 PS325-XX-XXXX
3 VLVE MOUNTING SCREWS: SS 0-32 x 2" HEX (5/32") SOCKET HED CP SCREW EXHUST PORTS FOR MUFFLERS/SILENCERS 3/8-8 NPT E3: ELECTRICL CONNECTION FOR: 2 BIT PRLLEL I/O (4-PIN M6 CIRCULR CONNECTOR) OR CN2.0B (6-PIN M6 CIRCULR CONNECTOR) INLET PRESSURE PORT 3/8-8 NPT MNULLY OPERTED VENTS PHILLIPS E2: ELECTRICL CONNECTION FOR: RS232 (6-PIN M6 CIRCULR CONNECTOR) E: ELECTRICL CONNECTION TO POWER SUPPLY (4-PIN M6 CIRCULR CONNECTOR) Property of SUNSTREM INCORPORTED DRWN BY: PPROVED BY: SPECIFICTION NOTES: SCLE: THIRD NGLE PROJECTION :3 DRWING PER SME Y4.5N-994 DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ NGLE +/-2 DEGREES 3 OF " BORE PS DRWING NUMBER: PS325-XX-XXXX
4 ROD END WIDTH CROSS FLTS WIDTH CROSS FLTS PS XX - XXXX - X - X - X - X - X 0F.000 0M 0M = 5/8-8 X.00 MLE 0ML = 5/8-8 X.25 MLE SCLE 0F = 5/8-8 X 0.75 FEMLE 2MH = 3/4-6 X.25 MLE W/ HEX M6M = M6X.5-6g X.250" MLE W/ HEX SCLE / 2 5/8-8 UNF-2Bx0.75 MIN /2 5/8-8 UNF - 2 7/8 CROSS FLTS 7/8 CROSS FLTS M6M WIDTH CROSS FLTS.25 SCLE / 2 2MH SCLE / 2 0ML SCLE / 2 M6x.5-6g mm HEX 5/8-8 UNF - 2 7/8 CROSS FLTS.25 Property of SUNSTREM INCORPORTED DRWN BY: PPROVED BY: 3/4-6 UNF - 2 SPECIFICTION NOTES: SCLE: THIRD NGLE PROJECTION :2 7/8 HEX DRWING PER SME Y4.5N-994 DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ NGLE +/-2 DEGREES 4 OF " BORE PS DRWING NUMBER: PS325-XX-XXXX
5 Table (unit ). PS325-XX-XXXX LM (LEFT MOUNT) P/N PS XXXX LM/BM/RB PS XXXX LM/BM/RM PS XXXX LM/BM/RM PS325-0-XXXX LM/BM/RM PS325-2-XXXX LM/BM/RM PS325-8-XXXX LM/BM/RM STROKE =STK = STK /2-3 UNC - 2B x.000 w n0.520 X 90~ LEFT PS325-XX-XXXX BM (BOTTOM MOUNT) BOTTOM TOP RIGHT /2-3 UNC - 2B x.000 w n0.520 X PS325-XX-XXXX RM (RIGHT MOUNT) Property of SUNSTREM INCORPORTED DRWN BY: PPROVED BY: SPECIFICTION NOTES: SCLE: DRWING PER SME Y4.5N-994 THIRD NGLE PROJECTION :4 /2-3 UNC - 2B x.000 w n0.520 X 90~ DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ NGLE +/-2 DEGREES 5 OF " BORE PS DRWING NUMBER: PS325-XX-XXXX LM/BM/RM
6 Table (unit ). P/N PS XXXX XT PS XXXX XT PS XXXX XT PS325-0-XXXX XT PS325-2-XXXX XT PS325-8-XXXX XT FRONT TRUNNION (FT) STROKE = STK n L6 = STK RER TRUNNION (RT).460 L6 NOTES: CONSULT FCTORY FOR FTV (FRONT TRUNNION VERTICL) ND RTV (RER TRUNNION VERTICL) OPTIONS.460 Property of SUNSTREM INCORPORTED DRWN BY: PPROVED BY: SPECIFICTION NOTES: SCLE: THIRD NGLE PROJECTION :4 DRWING PER SME Y4.5N-994 DO NOT SCLE DRWING: TOLERNCES ON DIMENSIONS 2 PLCES (0.00) +/ PLCES (0.000) +/ NGLE +/-2 DEGREES 6 OF " BORE PS DRWING NUMBER: PS325-XX-XXXX XT
TRIPPLE CYLINDER VERTICAL STEAM ENGINE DESIGNED BY Mr A. ZEVENHUIZEN, HEEMSKERK
TRIPPLE CYLINDER VERTICL STEM ENGINE DESIGNED BY Mr. ZEVENHUIZEN, HEEMSKERK THIS ENGINE WS REDRWN USING SOLIDWORKS DTED 01/0/1 DTE NVM DWG No JNURY 0.01.01 ( SHEETS) COMMENTS THIS STEM ENGINE WS PUBLISHED
More informationSTANDARDISED MOUNTINGS
STANDARDISED MOUNTINGS for series 449 cylinders conforming to ISO 21287 standard Series 434 MOUNTINGS CONFORMING TO ISO 21287 - ISO 15552 - AFNOR NF ISO 15552 - DIN ISO 15552 STANDARDS applications Low
More information4/2- and 4/3- Way Safety/Isolation Valve Model Z4 WEH 10 (Series 4X)
Function s n emergency on off isoltion vlve or on off isoltion/ypss vlve, primrly pplied with servo/proportionl systems Free flow through ports P nd T in ll pilot vlve positions Pilot operted y D 03, spool
More informationSeries Shockless Type Solenoid Operated / Solenoid Controlled Pilot Operated Directional Valves
DIRCIL CROLS Series Shockless ype Solenoid Operted / Solenoid Controlled ilot Operted Directionl Vlves he G-Series incorporte electronic circuits o enle djustment of the spool shifting time. specil spool
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More information4/3, 4/2 and 3/2 directional valve with wet-pin AC or DC solenoid
01/0 /3, / nd 3/ directionl vlve with wet-pin AC or DC solenoid Type WE...L7X.11 Size (NG) Up to 315 br Up to 0 L/min Contents Function nd configurtions Specifictions Symbols 03 Technicl dt 03 Electric
More informationSolenoid Operated Relief Valve
Solenoid Operted Relief lve JIS grphic symbols for hydrulic system Refer to the next pge. Fetures Low-noise models with further improvement on noise chrcteristics nbles circuit unloding nd dul/triple pressure
More information1) Actual pressure drop required for each metering land, up to the specified maximum flow rate is: Q ΔP actual. ) 2 PSI; (Q in GPM) actual Q rated
tlog HY14-255/US echnicl Informtion Generl escription proportionl directionl control vlves re high performnce, two stge pilot operted solenoid vlves with electronic spool position feedck, nd on-ord integrted
More informationPilot Operated Pressure Relief Valves with 2 or 3 Pressure Ratings Type DB 3U, Series 5X
ilot Operted ressure Relief Vlves with or ressure Rtings ype D U, Series RE 6/.9 RE 6/.9 Sizes,, Up to r Up to 6 L/min Replces: Specil fetures: Suplte mounting Mounting to DIN form E, Connection pltes
More informationBettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.
Bettis RGS F-Series Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators Output Torques to 500,000 in-lb (56,492 N m) Ductile Iron or Stainless-Steel Construction Temperatures from
More informationProportional spool valve with integrated electronics and spool position control with LVDT NG6 ISO
Proportionl spool vlve with integrted electronics nd spool position control with LVDT Flnge construction direct operted Q mx = l/min Q N mx = 4 l/min p mx = 3 r NG6 ISO 441-3 DESCRIPTION Direct operted
More informationMN4TB1/2 Series. Applicable cylinder bore size: ø20 to ø80
M port vlve DIN ril mount MN/ Series pplicle cylinder ore size: ø0 to ø0 MN W *0E JIS symol port vlve -position single solenoid -position doule solenoid -position ll ports closed -position //R connection
More information4/3 and 4/2 Proportional directional valve elements with flow sharing control (LUDV concept)
R 181-9/1.1 Replces: 1.11 1/1 / nd / Proportionl directionl vlve elements with flow shring control (LUDV concept) L88... (EDC-P) PTENT PENDING Summry Description Pge Generl specifictions 1 Ordering detils
More informationMax. Operating Pressure. Min. *2 Required Pilot Pres. Max. Pilot
DIRCIONL CONROLS Solenoid Controlled ilot Operted Directionl Vlves hese vlves re composed of solenoid operted pilot vlves nd pilot operted slve vlve. When solenoid is energised the pilot vlve directs the
More information5900 Elite Comfort Recliner Parts List 2
Page of 8 PRTS LIST Number Part Number 400530 STER, NYLON 3" TOTL LOK, (NO LONGER VILLE) 3 400540 STER, NYLON 3" DIRET. LOK, (NO LONGER VILLE) 566400 OLT-RRIGE ZIN /4-0 X /4 4 56604 NUT-/4-0 HEX NYLON
More informationCipriani Harrison Valves Corp.
Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle
More informationPRA/282000/M. Smart cylinders ISO 6431, VDMA and NFE Magnetic piston Double acting Ø 32 to 100 mm
Smart cylinders ISO, VDMA and NFE 9-00- Magnetic piston Double acting Ø to 00 mm Conforms to ISO, VDMA, NFE 9-00- Complete functional unit with integrated AS-Interface bus system or multipole connector
More informationEdition 3 September Air Angle Wrench and Nut Runner. QA6 and QA8 Series. Parts Information. Save These Instructions
660072 Edition 3 September 2007 Air Angle Wrench and Nut Runner QA6 and QA8 Series Parts Information Save These Instructions Module Exploded Diagram 7 5 9 7 2 9 50 3 8 3 38 39 8 9 20 2 33 22 23 3 2 3 37
More information3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators
lectric, Hydrulic, nd Pneumtic ctutors TL 1. Select Vlve ody including P ode (Vlve Size, v Rting, Port ode) or select Vlve ssemly correct (refer to Tle 3 nd Tle 3 lso) less ctutor ode (XXX) including the
More informationHARTING D-Sub Selection Guide
HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,
More informationSoft switching 4/2 and 4/3 directional valves with DC solenoids Model WE /A12..
R 3 183/06.98 Replces: R 3 18/05.9 R 3 183/06.98 Soft switching / nd /3 directionl vlves with DC solenoids Model WE...73 -.. /1.. Nominl sizes 6 nd 10 Series 6X (size 6)/3X (size 10) Mximum operting pressure
More informationMil-Stak PT/2016 PARTS MANUAL
Mil-Stak PT/0 PARTS MANUAL Mil-Stak Inc. 0 Hwy 0 West Fruitland Idaho Phone 0--0 ext - Main Assemblies ITEM PAGE P00 P00 P0 P0 PT 0 P00 Wheel Assembly Valve Block Frame Assembly PT Stackbed Assembly Receiving
More informationTHE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC.
P PINC VLVE Mod. S pag. Mod. S pag. Mod. S pag. Mod. SD pag. Mod. S pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S0 pag. Mod. S pag. 0 Mod. S pag. Mod. S pag. Mod. S pag. Mod. S pag. TE
More information6/2 way directional valve type 6/2UREM6 and 6/2URMM6
6/2 wy directionl vlve type 6/2UREM6 nd 6/2URMM6 NS6 dm 3 up to 35 MP up to 50 /min DT SHEET - OPERTION MNUL WK 421 540 03.2016 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM6...
More information1/8 Solenoid Operated Directional Valves, DSG-01 Series. Max. Operating Pressure Kgf/cm {Spool Type 60 Only 250}
/8 Solenoid Operted Directionl Vlves, DSG- Series WID RNG OF MODLSChoose the optimum vlve to meet needs from lrge selection ville. DIRCIONL CONROLS IC--- he DSG- series solenoid operted directionl vlve
More informationMOTORIZED 3-WAY VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTION KIT MODELS PB AND CF/CH
MOTORIZED -WY VLVE PPLICTION INSTRUCTIONS FOR LOW TEMPERTURE PROTECTION KIT 10017190 MODELS PB 50-001 ND CF/CH 0-07 WRNING Electrical Shock Hazard-- For your safety, turn OFF electrical power supply before
More informationThe 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options
The 505F Series //5-Way Ball Valve The 505F is a true multi-way ball valve with balanced fourseat construction. This full port valve is available in a variety of flow plans which can replace multiple two-way
More information10A-2 AB 299 AB A-2. Double rod type Adjustable stroke (retraction side) Double acting type. Series variations. Series. Cylinder bore
-2-2 9 Series variations ouble acting type ouble rod type djustable stroke (retraction side) Standard type Switch Set VL Set SV Set Standard type VL Set Standard type VL Set Series -2-2R -2V2-2K2-2 -2V2-22
More informationProportional spool valve NG4 ISO
Q mx = l/min 3 volume flow levels Q N mx = l/min p mx = 3 r NG ISO 1- DESCRIION Direct operted proportionl spool vlve with connections in -chmer system. recise spool fit, low lekge, long service life time.
More informationLGB JDWDS OCTOBER 2017 SHEET: 01 OF 06. NOTES: TITLE NG ELECTRIC LOCO OF THE MIX NITZ-ST. ERHARD LOCAL RAILWAY (GAUGE 184mm (7.
1 7. 00 1.7 97..1 0.1 90. 0.9 OTHER BBREVITIONS DP = DEEP D= DRILL FTER SSEMBLY D&T= DRILL ND TP FTER SSEMBLY CF = CLOSE FIT (SIZE FOR SIZE) PF = PRESS FIT PF= PRESS FIT FTER SSEMBLY PCD = PITCH CIRCLE
More informationProportional spool valve. NG4-Mini Wandfluh standard
roportionl spool vlve roportionl spool vlve Flnge construction Q mx = l/min 3 volume flow levels Q N mx = 1 l/min p mx = 3 r NG-Mini Wndfluh stndrd DESCRIION Direct operted proportionl spool vlve with
More informationEXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X DIRECTIVE ATEX ET IECEx
EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X DIRECTIVE ATEX ET IECEx CARACTERISTICS Hydrulic : Cetop. Mximum pressure in service : 0 Br. Nominl flow. : l/mn. 7 hydrulic symols.. Electric
More informationFeatures and Benefits
...................................................................................- Features and Benefits.............................................................................. How to Order....................................................................................
More information5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT
TABLE OF CONTENTS 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 5. DRIVE 6. ROW UNIT 7. OPTIONAL EQUIPMENT DRIVE Standard Turbofan 540, 450 & 1000 RPM with PTO Drive Your Monosem planter will be equipped
More informationElectroMechanical Cylinder LEMC
www.lmotion.ru lmotionmail@ya.ru.: (9)9160 ElectroMechanical Cylinder LEMC THE POWER OF KNOWLEDGE ENGINEERING www.lmotion.ru lmotionmail@ya.ru.: (9)9160 ElectroMechanical Cylinder LEMC enefits High efficiency
More informationIncremental Rotary Encoder G58
Shaft: Type S / L / H Hollow shaft: Type W Mechanical Data Housing diameter: mm Shaft:... 0 mm Hollow shaft:... mm Line counts:... 0.000 signals: S, KI, KS, HTL, TTL, O, Vpp, µapp onnector or output: axial
More informationPARABOLA EXERCISE 3(B)
PARABOLA EXERCISE (B). Find eqution of the tngent nd norml to the prbol y = 6x t the positive end of the ltus rectum. Eqution of prbol y = 6x 4 = 6 = / Positive end of the Ltus rectum is(, ) =, Eqution
More information10B-6 10B-6 AB 241 AB B-6 10B-6. Stroke Range. Double. type. Cylinder bore. Double brake type. Single brake type 10B-6. Cylinder bore (mm)
0 B- B- 1 Standard type, Switc Set Type Single brake type ouble brake type Series B- B- Cylinder bore (mm) Working fluid Lubrication Working pressure range roof test pressure Working speed range Working
More informationPRESSURE GAUGE SELECTORS
PRESSURE GUGE SELECORS Gauge isolator valves are designed to protect pressure gauges from pressure shocks when the pressure reading is not required; after each reading setting the selector to the closed
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDMHP3(4)L(T)2A00 Series
STANDARDS Valve body: ASME B16.34 Material certification: EN10204-3.1 MTR Quality assurance: ISO 9001:2008 Steel casting: MSS SP-55 Valve marking: MSS SP-25 Valve test: API 598 Direct mount: ISO 5211 End
More informationCV3000 Series. Characterized Insert Control Valves
CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut
More informationDirectional spool valves type UREP10 electrohydraulically
Directionl spool vlve type URE0 electro-hydruliclly operted NS0 up to 3,5 M up to 50 D SHEE - SERVICE MNU NUL dm 3 /min WK 42 60 05.202 LICION Directionl spool vlves type URE0 electrohydruliclly operted
More informationInstructions for Parts Books
Instructions for Parts Books The heading at the top of the page will be the same for the picture of the parts at it is for the page with the part numbers. Definition of column headings on part number pages:
More informationChapter 6. Hydraulic cylinders/rams (linear motors), and Lines/fittings. - Transforms the flow of a pressurized fluid into a push or pull of a rod.
Chapter 6. Hydraulic cylinders/rams (linear motors), and Lines/fittings - Transforms the flow of a pressurized fluid into a push or pull of a rod. 6. Single cting Rams Gravity, spring, etc. can force piston
More informationFluid Cooling Industrial PF Series
Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure
More informationDE-TYPE SHUNTING LOCO MOTOR OF THE DUTCH RAILWAYS SERIES
THIS DRWING REMINS THE PROPERTY OF JDW DRUGHTING SERVIES J..M.DE WL, RIGHTWELL STREET PPKUR NEW ZELND (09)9 IF IN DOUT SK DE-TYPE SHUNTING LOO MOTOR OF THE DUTH RILWYS SERIES 0-. THE FOLLOWING INFORMTION
More informationIMAGINE A WORLD WHERE YOUR CRITICAL SERVICE ACTUATION PROBLEMS ARE SOLVED
ROTARY ACTUATORS IMAGINE A WORLD WHERE YOUR CRITICAL SERVICE ACTUATION PROBLEMS ARE SOLVED A SERIES SINGLE RACK, FULL FEATURE PNEUMATIC ROTARY ACTUATORS A SERIES OHIO OSCILLATOR HIGH TORQUE, PNEUMATIC
More informationD D 200??? C C B B A A
D D 00 56 C C (.9) (.56) D 5 D XIL SLIP SUPPORT (ONE DIRECTION) FIXED SUPPORT FIXED SUPPORT FIXED SUPPORT XIL SLIP SUPPORTS C C XIL SLIP SUPPORT.9 5 -- Normal Hex Nut /- UNC, S. S. -- STUD, /- UNC, S.
More informationNO: ISSUED: DEC. 7, 1999 REVISED: SEPT. 4, 2002 HOSHIZAKI MODULAR ICEMAKER F-2000MLF(-C) MODEL (FINAL) PARTS LIST
NO: 71135 ISSUED: DEC. 7, 1999 REVISED: SEPT. 4, 2002 HOSHIZAKI MODULAR ICEMAKER MODEL F-2000MLF(-C) (FINAL) PARTS LIST H-0 March 1998 J-0 December 1998 K-0 February 2000 K-1 June 2000 L-0 December 2000
More information100Z-1 100Z-1 51 HA 50. Cushion ring Cushion ring. Type. Standard type. Switch Set
0Z-1 0Z-1 51 Type Nominal pressure Maximum allowable pressure Proof test pressure Minimum operating pressure Working speed range Working temperature range (ambient/fluid temperature) Structure of cushioning
More informationMPF SERIES RETURN FILTER
MPF SERIES The series of filters MPF has specifically been designed for use on mobile applications, agricultural machinery and power units. The MPF filter range is suitable for flow rates up to 750 l/min.
More information6940 Elite Care Cliner Parts List 3
Page of 7 () Number Part Number VERSION,F 400550 STER, NYLON 5" TOTL LOK (NO LONGER VILLE),,F 400560 STER, NYLON 5" IRETNL LOK (NO LONGER VILLE) G 00560K OSOLETE IRETIONL STER REPLEMENT KIT VERSION 400575
More informationElectroMechanical Cylinder LEMC
ElectroMechanical Cylinder EMC ElectroMechanical Cylinder EMC enefits High eficiency ong service life from use of SKF planetary roller screw Compact and robust structural design Modular concept with multiple
More informationLinear Motors with ATEX and IECEx Certification
Linear Motors with EX Linear Motors with TEX and IECEx Certification Designed for explosion proof environement Categories: gas zones 1/2, dust zones 21/22 Stainless steel housing EN1.444 / ISI 316 Completely
More informationOur policy is one of continued research and development. We therefore reserve the right to
D/99000, D/99000 ompact cylinders on-magnetic and magnetic piston Double acting Ø 12 to 160 mm ight weight ompact design, which is considerably shorter than IS/VDA or FA equivalent. ow friction characteristics
More information4/3 directional high-response control valves, direct operated, with integrated control electronics (OBE)
Courtesy of CM/Flodyne/Hydrdyne Motion Control Hydrulic neumtic Electricl Mechnicl (8) 426-548 www.cmfh.com 4/3 directionl high-response control vlves, direct operted, with integrted control electronics
More informationP303 Pressure Regulator
P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,
More informationCartridge Valves Technical Information
Quick reference CONTENTS CPF20... 8.2 CP600-5... 8. CP602-5... 8.4 20662 handle kit... 8.5 MP06... 8.6 MP2... 8.6 BC06... 8.9 BC0... 8.0 BC... 8. CP0-... 8. CP904-... 8.4 SC0... 8.5 SC... 8.6 DIN connectors...
More informationAKRON STANDARD HI LO TILT TABLE Models 8622, 8622T, 8631, 8631T, 8632, 8632T SERVICE MANUAL
AKRON STANDARD HI LO TILT TABLE Models 8622, 8622T, 8631, 8631T, 8632, 8632T SERVICE MANUAL 794-020 General Maintenance including Gas Strut It is recommended that the following checks and adjustments are
More informationFVBSS fixed volume bottle
N FVBSS fixed volume bottle Sampling System The SENSOR Fixed Volume Bottle Sampling System (FVBSS) provides a repeatable fixed volume of sample during each sampling process without stopping flow of the
More informationDirect Operated Type Solenoid Operated Proportional Directional Control Valve
Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.
More informationDirectional spool valves, directly operated, with manual and fluid logics actuation. Type WMM, WN and WP. Features. Contents
Directionl spool vlves, directly operted, with mnul nd fluid logics ctution ype WMM, WN nd W RE 22334 Edition: 2013-04 Replces: 22331 Size 10 Component series 5X Mximum operting pressure 350 r [5076 psi]
More informationPARTS LIST HT300T TOP MOUNT. LIT NO: L939 DATE: June 2008 REVISION: A
PARTS LIST HT300T TOP MOUNT LIT NO: L939 DATE: June 2008 REVISION: A HT300T TOP MOUNT PARTS LIST 2a Wingless, weld-on frame bracket, welded alignment Wingless, weld-on frame bracket with QUIK-ALIGN 2c
More information4/3, 4/2 and 3/2 directional valve with wet-pin DC solenoids
4/3, 4/2 nd 3/2 directionl vlve with wet-pin DC solenoids RE 23178-00/06.09 Replces: 02.03 1/12 ype WE SO407 Size 6 Component series 6X Mximum operting pressure 315 r [4569 psi] Mximum flow 60 l/min [15.8
More informationHudevad P100. Technical datasheet
Technical datasheet Key benefits Available in three depths Highly flexible in use Integrated top grille Harmonious and finished look Kundenedfal Low, streamlined design Ideal in front of glazing to prevent
More informationSIM Mono Module Push Pull Connectors
SIM Mono Module Push Pull Connectors EN RINC 809 Immeuble le Doublon avenue Dubonnet 90 COURBEVOIE Cedex FRNCE Version. Tel : (0) 9 0 0 00 Fax : (0) 9 0 0 0 www. amphenol-airlb. fr PRESENTTION PRT NUMBERING
More informationPN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings
I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings
More information35P-3 HH 3 HH 2 35P-3. f32 f40. f50 f63. f80 f100. Switch Set. Type Standard type Switch Set
f f f f f f Kind of piston seal U seal Slipper Seal U seal Slipper Seal Nominal pressure. MPa Maximum allowable pressure. MPa Proof test pressure MPa Minimum operating pressure. MPa or less Working speed
More information12 FIBER DUPLEX LC CASSETTES METHOD B, (ENDS B1 AND B2)
THIS COPY IS PROVIDED ON RESTRICTED SIS ND IS NOT TO E USED IN NY WY DETRIMENTL TO THE INTERESTS OF PNDUIT CORP.. 0... REF. NOTES:. SEE CURRENT CTLOG FOR PRT NUMER SUFFIXES TO INDICTE COLOR ND/OR PCKGE
More information7000 SERIES THUMBWHEEL SWITCHES
7000 SERIES THUMBWHEEL SWITCHES The combines heavy-duty construction and a compact package size. Designed to meet demanding military performance specifications, the switch features a unique one-piece housing
More information4/3-, 4/2- and 3/2-way directional valves with wet pin DC or AC solenoids, Type.WE 10../.C
RE 2 27/05.98 Replces: 2 1 /-, /2- nd /2-wy directionl vlves with wet pin DC or AC solenoids, Type.WE 10../.C Nominl size 10 Series X (individul connections) Series X (centrl connections) Mximum operting
More informationFlow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min
RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division
More information4/3-, 4/2- and 3/2-way directional valves with wet pin DC solenoids Type WE 6../.S
RE 2 /2.02 Replces: 07.02 /-, /2- nd /2-wy directionl vlves with wet pin DC solenoids Type WE../.S Nominl size Series X Mximum operting pressure 5 r Mximum flow 0 L/min H59/98 Type WE EX/SG2N9K/V with
More informationGRANT COUNTY PORT DISTRICT NO. 1 GRANT COUNTY
GRNT COUNTY PORT DISTRICT NO. GRNT COUNTY WSHINGTON PORT COMMISSIONERS Curt. Morris President rian. Kuest Secretary Patric F. Connelly Vice President 80 IRON HORSE COURT YKIM, WSHINGTON 9890 (509) 45-48
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More information210H-3 HA 289 HA H-3. f80 f160. f140. f125. f50. Type. Standard type. Adaptable fluid. Seal material. Phosphate ester fluid. Water in oil fluid
288 28 Type Nominal pressure Maximum allowable pressure roof test pressure Minimum operating pressure orking speed range orking temperature range (ambient/fluid temperature) Structure of cushioning Adaptable
More informationPARTS LIST R E8617C Qty. Description Alternative Price Q p. Pos. Code Price Q.ty per pck.
Descrition R86170001-3 PARANA' 230/50 -G-LWS E8617C002-01 001 4.608.0142 236.15 1 1 PLASTIC BASE FOR PARANA' 0 0 002 3.002.0176 1.25 18 1 SCREW M5X16 7985 0 0 003 3.004.0017 1.25 18 1 WASHER D.5X10 0 0
More informationFDB1050REB2 FDB1050REC2 FDB1050REM2 FDB1050REQ2 FDB1050RES2
Product No. B2 C2 M2 Q2 S2 Series Built-in 24" Built-in 24" Built-in 24" Built-in 24" Built-in 24" Color black stainless silver mist bisque white Owner's Guide English 154591101 154591101 154591101 154591101
More informationSeries P02-23Sx80-HP. Series P02-23Sx80-HP 2. P02-23Sx80F-HP/220x P02-23Sx80F-HP/290x P02-23Sx80F-HP/20x60 5. P02-23Sx80F-HP/350x410 13
Series P2-23Sx8-HP Series P2-23Sx8-HP 2 P2-23Sx8F-HP/2x6 5 P2-23Sx8F-HP/4x1 6 P2-23Sx8F-HP/7x13 7 P2-23Sx8F-HP/1x16 8 P2-23Sx8F-HP/14x2 9 P2-23Sx8F-HP/16x22 1 P2-23Sx8F-HP/22x28 11 P2-23Sx8F-HP/29x35 12
More information6/2 way directional valve. Type 6/2UREM10-1 -
6/2 wy directionl vlve type 6/2UREM0 NS 0 dm up to 5 MP up to 80 /min DT SHEET - SERVICE MNU NUL WK 42 590.202 PPLICTION Moile 6 wy 2 position stckle directionl vlves type 6/2UREM0... re intended for hydrulic
More informationKiel Probes. General Information
Kiel s Generl Informtion Aerodynmic Properties Kiel probes re used to mesure totl pressure in fluid strem were te direction of flow is unknown or vries wit operting conditions. Teir correction fctor is
More information4/3, 4/2 and 3/2 directional valve with fluidic actuation
4/3, 4/2 nd 3/2 directionl vlve with fluidic ctution RE 22282/04.10 Replces: 08.08 1/12 ype W, WH Size 6 Component series 6X (W), 5X (WH) Mximum operting pressure 315 r [4569 psi] Mximum flow 60 l/min
More information4/3 directional high-response control valves, direct operated, with integrated control electronics (OBE)
4/3 directionl high-response control vlves, direct operted, with integrted control electronics (OE) RE 2967/11.5 Replces: 2.3 1/14 ype 4WRSE Sizes 6 nd 1 Series 3X Mximum operting pressure 315 r Mximum
More information4/2 and 4/3 proportional directional valves direct operated, with electrical position feedback, without/with integrated electronics (OBE)
4/2 nd 4/3 proptionl directionl vlves direct operted, with electricl position feedck, without/with integrted electronics (OE) Types 4WRE nd 4WREE Nominl sizes 6 nd 0 Component series 2X Mximum operting
More informationManually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.
Manually Operated Directional s DM- / / DMG- / / / / hread Connection / Mounting Specifications hreaded Connections Numbers DM--C - DM--D - DM--D - DM--B - DM- -C - DM- -D - DM- -D - ( ) (.) (.) (.) (.)
More informationAK-47/74 Barrel and Front Trunnion Rivet Removal
AK-47/74 Barrel and Front Trunnion Rivet Removal The following steps are used for barrel center pin, barrel and front trunnion rivet removal on AK- 47/74 type rifles. Special jigs and fixtures were used
More informationHints for Exercise 1 on: Current and Resistance
Hints for Exercise 1 on: Current nd Resistnce Review the concepts of: electric current, conventionl current flow direction, current density, crrier drift velocity, crrier numer density, Ohm s lw, electric
More informationHiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F
HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to
More information4KB1/2/3/4 Series. Applicable cylinder bore size: 20 to 160mm. Pilot operated soft spool valve. Compressed air
Discrete vlve Su se porting, port pilot operted vlve K1/2// Series pplicle cylinder ore size: 20 to 0mm CD DT VILLE. JIS symol port vlve 2position single port vlve 2position doule port vlve position ll
More informationSequence Cartridge Valves
Sequene Vlves Type Pge Pilot Operted, lned Piston Diret ting with Reverse Flow Chek 7 Kik-down, Pilot Operted, lned Piston ir Controlled, Pilot Operted, lned Piston 9 Diret ting without Reverse Flow Chek
More informationMADILL MBT GRAPPLE RETURN TO INDEX
MADILL MBT GRAPPLE RETURN TO INDEX MBT CONTROL VALVE Additional Parts Breakdown for: - Outrigger Sections - Rotate Section - End Plate E 00- page Valve section Basic element without additional functions
More informationMounting kits for insulation of power transistors
ounting kits for insulation of power transistors tel. 0..6.6.6 www.elitaliaweb.it fax 0.6.6.0.09 info@elitaliaweb.it ST STS ST 0 STS 0 for transistor TO TO TO 0 TO 0 version with mica wafer S with silicone
More informationRotary modules.
Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM
More informationPart No. Part Name Spec.
NPR50A_pl160513 NP50A / NR50A (*Include ) 2016/5/13 Title Part Part Name Spec. 1 1 1.BASE W083 HEX SOCKET HEAD CAP SCREW M8 25 2 Y Y Y: YES 1 2 1.BASE PM62 REAR GRIP 1 N N N: NO 1 3 1.BASE W051 HEX SOCKET
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationM/60210/M Miniature rotary actuators
M/6020/M Miniature rotary actuators Double acting - Magnetic piston - Ø 2 and 20 mm Smooth operation with zero backlash Lightweight ompact envelope dimensions Integral magnets for positional feedback TEHNIL
More informationCarousel 6 Plus Reaction Station
1/5 Carousel 6 Plus Reaction Station Référence Description Qté Prix (2011) RR99943 System 34 - Heated System - Basic 5,948.50 RR99942 System 33 - Heated System - Basic + Hotplate 6,971.50 RR99944 System
More information3D Drawing - CARIF 260 BSA
D Drawing - CARIF 0 BSA DRAWING CODE DRAWING NAME NUMBER ASS000 Basement ASS00 Vice Base ASS00 Vice A ASS00B Vice B ASS00 Frame A ASS00B Frame B ASS000 Frame Cylinder A ASS000B Frame Cylinder B ASS000
More informationI-FORCE Ironless linear motors
I-FORCE Ironless linear motors Parker Trilogy s I-Force ironless linear motors offer high forces and rapid accelerations in a compact package. With forces ranging from 5.5 lbf (24.5 N) - 197.5 lbf (878.6
More information