SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

Size: px
Start display at page:

Download "SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz"

Transcription

1 RANGE OF USE Flow rate: from 0 to 0 m/h Manometric head: up to mce Temperature of the fluid: from 0 to + C Ambient temperature: -0 to +0 C Max. operating pressure: bars (version SIE) bars (version LRE) FLOSKID JETSON SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 0 Hz Floskid on sur consultation consulation Floskid standard APPLICATIONS The Floskid is a turnkey system of electronic (LRE / SIE) pumps, factory tested, pre-assembled and compact. They are mounted in cascade on a single frame, and fitted with a SCe-HVAC switch box. The pumps are designed for variable-output heating, air conditioning and cooling systems, in residential blocks, offices and shops or industry. 0 ADVANTAGES 0 Qm /h Highly energy-efficient: improves overall efficiency via a system of pumps in cascade. Easy to install: compact design, preassembled. Acoustic comfort: reduced size and power of motor, reducing noise. Highly reliable: system bench-tested water-filled. Space-saving: compact all-in-one system mounted on a single frame. Improved help to the client, and reduction in administrative procedures: a single contact (Salmson) for the complete system. Standard version can be delivered in only four weeks. N.T. N -/F. - Éd./0-

2 FLOSKID JETSON BASIC CONSTRUCTION Main components Material Manifolds Painted steel Base frame Galvanised steel TRANSPORT INSTALLATION Delivery In its standard version, the Floskid will be delivered within weeks of order. Transport The smaller systems are entirely covered in a transparent plastic sack, and are delivered as a single unit on a pallet. For the larger systems, only the vulnerable parts, the pumps and the control cabinet are covered in a transparent plastic sack, and delivered separately (pumps on metal frame on the one hand and manifolds separate), on three pallets. Installation All that needs to be provided are the connections to the intake and output pipes and the connection to the electricity supply. DESCRIPTION OF THE PRODUCT Livraison Mechanical and hydraulic components of the installation The compact installation is mounted on a steel frame with vibration dampers (Item ). This is composed of a group of or electronically regulated in-line pumps (Item ), connected together by an intake manifold (Item ) and an output manifold (Item ). On each pump, a stopcock (Item ) is mounted on the intake and output, and a non-return valve (Item ) is mounted on the output. A flanged joint (Item.) is placed between the stopcock and the non-return valve (see fig. ). A sub-assembly with a differential pressure sensor (Fig., item.) a pressure gauge (Fig., item.) and gate valve (Fig., item.) is mounted on the output manifold. The switch box (Item ) is mounted on the frame on one or two brackets (Item ).All the electrical components are delivered ready-wired.. Electronically-regulated in-line pumps. Sce HVAC Switch box. Steel frame with vibration dampers. Intake manifold. Output manifold. Stopcock. Non-return valve. Pressure gauge. Control box. Sub-assembly with differential pressure sensor. Gate valve. Flanged joint

3 x FLOSKID JETSON TECHNICAL DATA SCE HVAC BOX DESCRIPTION OF THE SCE HVAC BOX Supply voltage [V]: ~00 V (L, L, L, PE) Frequency [Hz]: 0/0 Hz Control voltage [V]: V DC; 0V AC Nominal current [A]: See the motor plate Protection class: IP Main shut-off [A]: See the electrical diagram Ambient temperature [ C]: 0 to +0 C Electrical safety: degree of pollution: II OPERATION The SCe switch box is controlled by a microprocessor which runs a system of to pumps. The regulation value is measured by un sensor and the pumps are controlled according to the load. A transmitter provides the actual value from the measured value of the system by sending a to 0 ma signal. The regulator maintains the constant value of the system by comparing with the set-point, Fig. A) and the actual value. If there is no «External Off» message and no error, the base pump whose speed is being regulated runs at minimum speed. If the power of this pump is not sufficient and the maximum permitted speed, a second pump cuts in if the pressure remains below set-point. This pump takes over control (Fig. B) and the previous lead pump continues to run at maximum. This is repeated with output increasing up to the pump maximum (see Fig. C). If the output falls, the pump being controlled stops when it reaches its minimum permitted speed and if the need remains greater than the set-point. At that point, the previous pump in the cycle takes over the role of lead pump.. Main shut-off: Power on/off of the box. Man-Machine Interface (MMI): LCD display to show the operating data, LEDs to show the general status (Operating /Fault), button to move around the menus and parameters. Pre-programmed automaton with microcontroller. Protection of pumps and speed control via circuit-breaker Qm /h BACKUP PUMP To ensure the security of the system, the Floskid has a backup pump. This pump does not take part in the standard regulation cycle. It only comes on if there is a fault on another pump. The optimisation of the running time of the pumps ensures that each pump is used as backup pump in turn. The backup pump is also started up if the test function is activated. The parameters of this function are pre-adjusted in the factory and can only be altered by the SALMSON after-sales service. PERMITTED MODES OF REGULATION CHANGE OF PUMP To allow the pumps to be brought into operation equally, various mechanisms are used for changing pumps. Each time the system is started up anew (after all the pumps have been switched off) the lead pump changes. Also, an automatic changeover of pumps can be activated so that each becomes lead pump in turn. The time between two changeovers can be defined. x Qm /h Delta pressure constant Δp c Delta pressure variable Δp v (only for the lead pump).. Pressure constant p- c Temperature differential constant between two points of the installation ΔT c* Speed control dependent on the input temperature n = f (Tx)* Speed controlled by external analogue signal n = f(ai) EXTERNAL HALT The system can be deactivated by an external OFF switch. All the pumps are halted. x * Mode available by default on the SCe-HVAC box. The temperature sensor is not supplied. Qm /h

4 JETSON FLOSKID % [] Power Puissance consumption absorbée P,,, 0, % [] % [] FloSKID- LRE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % [] Hauteur Discharge de head refoulement 0 0 %[] Puissance Power consumption absorbée P %[] m Valeurs NPSH Values NPSH %[] FloSKID- LRE0-/ SC--T 0 %[] 0 %[] 0 %[] 0 %[] 0 %[] %[] 0 %[] 0 %[] 0 %[] 0 0 % [] Power Puissance consumption absorbée P % [] % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] Discharge head 0 0 % [] Power input consumption P P % [] m NPSH-values Values,,, % [], 0, 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/, SC--T 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % []

5 FLOSKID JETSON Discharge Hauteur de head refoulement % [] Power Puissance consumption absorbée P % [] % [] FloSKID- LRE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] % [] Power Puissance consumption absorbée P % [] % [] FloSKID- LRE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] Discharge head % [] Power consumption input P P NPSH-values Values m % [] FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] Power Puissance consumption absorbée P % [] % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/, SC--T 0 % [] 0 % [] % [] 0 % [] 0 % [] 0 % []

6 JETSON FLOSKID 0 % [] Power Puissance consumption absorbée P % [] % [] FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] FloSKID- SIE0-/, SC--T Discharge Head head 0 0 % [] 0 % [] 0 % [] 0 0 % [] 0 % [] 0 % [] 0 % [] % [] Power consumption input P P 0 % [] 0 % [] m NPSH-values Values, 0 % [],, % [], 0, % [] Power Puissance consumption absorbée P % [] % [] FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] Discharge Head head 0 % [] Power consumption input P P % [] m NPSH-values Values FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % []

7 FLOSKID JETSON Hauteur Discharge de head refoulement % [] Puissance Power consumption absorbée P % [] m Valeurs NPSH Values NPSH % [] FloSKID- LRE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] FloSKID- SIE0-/, SC--T 0 0 % [] 0 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] Power Puissance consumption absorbée P 0 % [] % [] Hauteur Discharge de head 0 refoulement % [] Puissance Power consumption absorbée P % [] m Valeurs NPSH Values NPSH % [] FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] Head Discharge head % [] Power input consumption P P % [] m NPSH-values Values FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % []

8 JETSON FLOSKID FloSKID- LRE0-/ SC--T 0 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] Power Puissance consumption absorbée P 0 % [] % [] 0 % [] % [] Discharge Head head 0 % [] Power consumption input P P % [] NPSH-values Values FloSKID- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % [] Discharge Hauteur de head refoulement 0 0 % [] Power Puissance consumption absorbée P 0 % [] 0 % [] 0 % [] 0 % [] FloSKID-- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] Discharge Hauteur de head refoulement 0 0 % [] Power Puissance consumption absorbée P 0 % [] 0 % [] 0 % [] 0 % [] FloSKID-- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % []

9 FLOSKID JETSON Hauteur Discharge de head refoulement 0 0 % [] Puissance Power consumption absorbée P P 0 % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/, SC--T 0 % [] 0 % [] 0 % [] % [] 0 % [] Hauteur Discharge de head refoulement 0 % [] Puissance Power consumption absorbée P % [] m Valeurs NPSH Values NPSH FloSKID- SIE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % [] 0 0 % [] Power Puissance consumption absorbée P 0 0 % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 Hauteur Discharge de head refoulement % [] Puissance Power consumption absorbée P % [] m Valeurs NPSH Values NPSH % [] FloSKID- LRE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % []

10 JETSON FLOSKID 0 0 % [] Power 0 Puissance consumption absorbée P 0 % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-0/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] % [] % [] Power Puissance consumption absorbée P 0 % [] FloSKID- SIE0-/, SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % [] 0 0 % [] Power Puissance consumption absorbée P 0 0 % [] 0 % [] 0 % [] 0 % [] FloSKID-- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 0 % [] Power Puissance consumption absorbée P 0 0 % [] 0 % [] 0 % [] 0 % [] FloSKID-- SIE0-/ SC--T 0 % [] 0 % [] 0 % [] 0 % [] 0 % [] 0 % []

11 FLOSKID JETSON 0 0 % [] Power Puissance consumption absorbée P % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-/ SC--T 0 % [] 0 % [] % [] 0 % [] 0 % [] 0 % [] 0 0 % [] Power Puissance consumption absorbée P % [] % [] 0 % [] 0 % [] 0 % [] FloSKID- SIE0-0/ SC--T 0 % [] 0 % [] 0 % [] % [] 0 % [] 0 % []

12 FLOSKID JETSON H HP H ELECTRICAL FEATURES AND DIMENSIONS P X P L Hauteur Nominalnominale height (m) (m) Maximum Pression operating maxi de pressure service Niveau Noise level de bruit of the du système system (db) (db) Nett Poids weight net (kg) (kg) Gross Poidsweight brut (kg) (kg) X± H± H± L± P± P± Collecteurs Manifolds Capteur Pressure de sensor pression Pressure Manomètre gauge Courant Nominal nominal current FloSKID--LRE0-/.-SC--T FloSKID--LRE0-/-SC--T FloSKID--SIE0-/.-SC--T FloSKID--LRE0-/.-SC--T FloSKID--LRE0-/-SC--T FloSKID--SIE0-/.-SC--T FloSKID--LRE0-/.-SC--T FloSKID--LRE0-/-SC--T FloSKID--SIE0-/.-SC--T FloSKID--LRE0-/.-SC--T FloSKID--LRE0-/-SC--T FloSKID--SIE0-/.-SC--T FloSKID--LRE0-/-SC--T Nominal débit nominal flow rate of système system 0 Nb nbof pompe backup secours pumps N Item no. Name Désignation article Number nb pompes of main principales pumps FLOSKID data DN DN DN DN 0 DN 0 DN 0 DN 0 DN 0 DN 0 DN 00 DN 00 DN 00 DN 00 DSP0 DSP0 DPS0 DSP0 DSP0 DPS0 DSP0 DSP0 DSP0 DSP0 DSP0 DPS0 DSP

13 FLOSKID JETSON ELECTRICAL FEATURES AND DIMENSIONS N Item no. article Désignation Name Number nb pompes of main principales pumps Nb nb of pompe backup secours pumps Nominal débit nominal flow rate of système system Hauteur Nominal nominale height (m) Maximum Pression operating maxi de pressure service Niveau Noise level de bruit of the du système system (db) Nett Poids weight net (kg) Gross Poids weight brut (kg) X± H± H± L± P± P± Collecteurs Manifolds Capteur Pressure de sensor pression Pressure Manomètre gauge Courant Nominal nominal current FloSKID--LRE0-/-SC--T DN 00 DSP0 0-. FloSKID--SIE0-/.-SC--T 0 00 DN 00 DPS0 0-. FloSKID--LRE0-/-SC--T DN 0 DSP0 0-. FloSKID--LRE0-/-SC--T 000 DN 0 DSP0 0-. FloSKID--SIE0-/.-SC--T DN 0 DPS0 0-. FloSKID--LRE0-/-SC--T DN 0 DSP0 0-. FloSKID---SIE0-/-SC--T DN 0 DSP0 0-. FloSKID--SIE0-/-SC--T DN 0 DPS0 0- FloSKID--LRE0-/-SC--T 000 DN 0 DSP FloSKID---SIE0-/-SC--T DN 0 DSP FloSKID--SIE0-/-SC--T DN 0 DSP0 0-0 FloSKID--SIE0-/.-SC--T DN 00 DSP FloSKID---SIE0-/-SC--T DN 00 DSP FloSKID--SIE0-0/-SC--T DN 00 DPS FloSKID--SIE0-/.-SC--T DN 00 DSP FloSKID---SIE0-/-SC--T DN 00 DSP FloSKID--SIE0-0/-SC--T DN 00 DPS0 0-. Sce-HVAC box data N Item article no. Name Désignation Puissance Power of coffret Sce Sce HVAC HVAC box Dénomination Name of box coffret Dimensions Size of box coffret (HxWxD) [mm] Wiring Câblage of coffret box FloSKID--LRE0-/.-SC--T, kw S-CTRL-SCE-H-x0,-,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/.-SC--T, kw S-CTRL-SCE-H-x0,-,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/.-SC--T, kw S-CTRL-SCE-H-x,-,0-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/.-SC--T, kw S-CTRL-SCE-H-x,-,0-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm 0 FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,-,0KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,-,0KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm FloSKID---SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G, mm FloSKID--SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G mm FloSKID--LRE0-/-SC--T kw S-CTRL-SCE-H-x,0-,KW-T-WM-PKG 00x00x G, mm 00 FloSKID---SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G, mm 0 FloSKID--SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G mm 0 FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm 0 FloSKID---SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G, mm 0 FloSKID--SIE0-0/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G mm 0 FloSKID--SIE0-/.-SC--T, kw S-CTRL-SCE-H-x,KW-T-WM-PKG 00x00x G, mm 0 FloSKID---SIE0-/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G, mm 0 FloSKID--SIE0-0/-SC--T kw S-CTRL-SCE-H-x,0KW-T-WM-PKG 00x00x G mm

14 JETSON FLOSKID ELECTRICAL FEATURES AND DIMENSIONS Pump data N Item article no Désignation Name N Item Article no Pompes Three pole phase triphasées -pole Pumps 00V 0 Hz Pump débit nominal pompe output Puissance Nominal nominale power Courant Nominal nominal current FloSKID--LRE0-/.-SC--T LRE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T 0 SIE0-/.-G, kw, A FloSKID--LRE0-/.-SC--T LRE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T 0 SIE0-/.-G, kw, A FloSKID--LRE0-/.-SC--T 0 LRE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T SIE0-/.-G, kw, A FloSKID--LRE0-/.-SC--T 0 LRE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T SIE0-/.-G, kw, A 0 FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T 0 SIE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID--SIE0-/.-SC--T 0 SIE0-/.-G, kw, A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A FloSKID---SIE0-/-SC--T SIE0-/-G kw, A FloSKID--SIE0-/-SC--T SIE0-/-G kw A FloSKID--LRE0-/-SC--T LRE0-/-G kw, A 00 FloSKID---SIE0-/-SC--T SIE0-/-G kw, A 0 FloSKID--SIE0-/-SC--T SIE0-/-G kw A 0 FloSKID--SIE0-/.-SC--T SIE0-/.-G, kw, A 0 FloSKID---SIE0-/-SC--T SIE0-/-G kw, A 0 FloSKID--SIE0-0/-SC--T SIE0-0/-G kw 0, A 0 FloSKID--SIE0-/.-SC--T SIE0-/.-G, kw, A 0 FloSKID---SIE0-/-SC--T SIE0-/-G kw, A 0 FloSKID--SIE0-0/-SC--T SIE0-0/-G kw 0, A FLOSKID ACCESSORIES SAP title Item no. Details SC-OPTION MODBUS RTU (SLAVE) Enables the main parameters of the system to be communicated over a modbus network SC-OPTION BACNET MSTP (SLAVE) Enables the main parameters of the system to be communicated over a BacNet network SC-OPTION LON (SLAVE) Enables the main parameters of the system to be communicated over a Lon network. PCBA OPTION EXM SC SET Individual operation and fault reports: adds additional individual Operation and Error outputs to the pumps On demand H-0-A switch to select the operating modes of a pump: allows a physical Auto/Manu/Off switch to be added to each pump (Standard on a CC box)

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

Water terminal control solutions

Water terminal control solutions Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97 Heat Meter WR 200-D electronic computing device for heat quantity measuring Heat transfer medium water steam Any flow sensor with analog signal connectable 2 temperature inputs for Pt100 in four-wire circuit

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Installation Operation Commissioning Maintenance

Installation Operation Commissioning Maintenance NA 09.13 H 09-2011 Microchip and LCD display electronic regulation and signaling electronic module for liquid coolers and heat pumps Installation Operation Commissioning Maintenance 1 CONTENTS 1 IMPORTANT

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

Variable swirl diffusers

Variable swirl diffusers Swirl diffusers, Variable swirl diffuser OD- Application Diffuser is designed for air conditioning of rooms with floor to ceiling highs of to 0 m and high induction requirements. It is suitable for large

More information

SMB20, SMB30 Series. UK market only

SMB20, SMB30 Series. UK market only SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART HORIZONTAL MULTISTAGE ELECTRIC PUMPS SERIES e-hm SMART UK market only Cod. 1911 Rev. A

More information

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION HD2016 [ GB ] Weighing rain gauge Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION [ GB ] HD2016 Weighing rain gauge [ GB ] HD2016 is a rain gauge that detects the weight of the

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

PHOS 15 LED PROJECTOR

PHOS 15 LED PROJECTOR PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

TETRIS W FC NG kw

TETRIS W FC NG kw 40 640 kw General description TETRIS W FC/NG is a free cooling chiller for indoor installation that integrates uncoupling exchanger, 3-way modulating valve, inverter-controlled pump on the source side

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Description of operation...5. Installation...7. Choice and selection...8. SMB20, SMB30 Series Electric pump range and characteristics...

Description of operation...5. Installation...7. Choice and selection...8. SMB20, SMB30 Series Electric pump range and characteristics... SMB, SMB3 Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART VERTICAL MULTISTAGE MONOLITHIC ELECTRIC PUMPS SERIES VM SMART HORIZONTAL MULTISTAGE ELECTRIC

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

Multifunctional Thermostatic Circulation Valve MTCV

Multifunctional Thermostatic Circulation Valve MTCV Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version

More information

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact EL Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free precise control via DSI signal, switchdim or corridorfunction Nominal life

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications Technical Description Hydraulic Excavator A 95 C HD litronic` Machine for Industrial Applications Operating Weight 165,800 170,0 lb Engine Output 36 hp (0 kw) Technical Data Engine Rating per ISO 99 0

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Clausing Industrial, Inc. Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Clausing Industrial, Inc. Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm

More information

SMB20 - SMB30 Series. 50 Hz

SMB20 - SMB30 Series. 50 Hz Hz SMB - SMB Series VARIABLE SPEED BOOSTER SETS WITH e-sm DRIVE VERTICAL MULTISTAGE ELECTRIC PUMPS SERIES e-sv SMART VERTICAL MULTISTAGE CLOSE-CLOUPED ELECTRIC PUMPS SERIES VM SMART HORIZONTAL MULTISTAGE

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.

More information

Pressure independent balancing and control valve AB QM DN

Pressure independent balancing and control valve AB QM DN Data sheet Pressure independent balancing and control valve AB QM DN 10-250 The AB QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.

More information

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Variable Speed 20 Single and Multi-spindle, Belt Drive Industrial Drill Presses www.clausing-industrial.com Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses Two Speed Variable Speeds 150-2000rpm Variable Speeds 200-1300rpm Variable Speeds 300-2000rpm

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

1 Linear feeder 2 Track 3 Cover 4 Side plate 5 Trim weight 6 Sub-structure. 8 Feeding technology afag.com

1 Linear feeder 2 Track 3 Cover 4 Side plate 5 Trim weight 6 Sub-structure. 8 Feeding technology afag.com Linear feeder Track Cover Side plate Trim weight Sub-structure 8 Feeding technology 0 Linear feeder Linear feeder Linear feeder HLF-M Linear feeder HLF-P 8 Control devices PSG Accessory HLF Linear feeder

More information

AIR COOLED CONDENSING UNIT

AIR COOLED CONDENSING UNIT NEW EVOLUTION SERIES AIR COOLED CONDENSING UNIT OUTDOOR AIR COOLED CONDENSING UNIT ORIGINAL MANUFACTURED EQUIPMENT NEW EVOLUTION 7 & 8 SERIES BA-506-5 AUS Evolution Air Cooled Condensing Unit Series Content

More information

KSAb

KSAb --------------------------------------------------------- ---------------------------------------------------------------------- Electronic slave and constant flow regulator for air flow regulation FUNCTION

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

VIBRATION METER. Instruction Manual.

VIBRATION METER. Instruction Manual. VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

High Capacity Double Pillar Fully Automatic Bandsaw. p h a r o s 2 8 0

High Capacity Double Pillar Fully Automatic Bandsaw. p h a r o s 2 8 0 High Capacity Double Pillar Fully Automatic Bandsaw p h a r o s 2 8 0 A high-quality product from German mechanical engineering pharos - a beacon amongst automatic bandsaws Klaeger has been a leading manufacturer

More information

Safety Barriers Series 9001, 9002 Standard Applications

Safety Barriers Series 9001, 9002 Standard Applications Standard s Analog input with transmitter Smart 9001/51-80-091-141 09949E0 Load of transmitter U N = + 0 V... 35 V I N = 3.6 ma... ma R L ( 350 O U min (I N= 0 ma) U N - 9.5 V 14 V U N ( 3.5 V > 3.5 V Maximum

More information

Mechanical flow-rate controllers

Mechanical flow-rate controllers L D L D L D Mechanical flow-rate controller MRP-1 (Circular) Description With the circular air flow controllers with automated action, the air flow rate is controlled via an asymmetrical control flap pivoting

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact FL ballasts EL TC-F TC-SEL TC-L HE TC-DD Tc PCA TC ECO Y II, 7 W ECO compact Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A BAT Noise-free

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

EPIV electronic pressure-independent characterised control valve EPIV

EPIV electronic pressure-independent characterised control valve EPIV electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve

More information

1/54 Circulation pump, safety valve, expansion vessel

1/54 Circulation pump, safety valve, expansion vessel 1/54 Circulation pump, safety valve, expansion vessel pressure loss efficiency of pump secured heat output safety valve sizing expansion vessel sizing Circulation pump 2/54 similar principle as for heating

More information

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade. TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and

More information

Electrolysis System CHLORINSITU V (PLUS)

Electrolysis System CHLORINSITU V (PLUS) Output of 100 3.500 g/h of ultra-pure active chlorine (hypochlorous acid) Electrolysis systems of the type CHLORINSITU V generate ultrapure active chlorine using the unique vacuum method with the membrane

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications

More information

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000 Suction capacity in m /h m /h 20 2000 1000 0 00 2 200 1 100 10 700 0 0 400 00 200 100 0 100 200 00 400 0 0 700 800 900 1000 1100 Suction pressure auge pressure mbar ELMO- vacuum pumps and compressors convey

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

Electronic pressure-independent characterised control valve EPIV

Electronic pressure-independent characterised control valve EPIV Electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Rotary modules.

Rotary modules. Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM

More information

flexotherm 230V Heat pump technical specification

flexotherm 230V Heat pump technical specification flexotherm 230V Heat pump technical specification The flexotherm 230V heat pump is available in 5, 8 and 11kW models Connects to two different sources - ground or water One of the quietest heat pump ranges

More information

KZMb

KZMb -------------------------------------------------------- Electronic zone controller for pressure regulation ---------------------------------------------------------------------- FUNCTION KZM is an electronic

More information

SINAMICS G120X. Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019

SINAMICS G120X. Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019 SINAMICS G120X Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019 An infrastructure drive for pumps, fans and compressors Siemens introduces an exciting new addition to

More information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details) Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1. Motors Automation Energy Transmission & Distribution Coatings Servo Drive SCA06 V1.5X SCA06 V1.4X Series: SCA06 Language: English Document Number: 10003604017 / 01 Software Version: V1.5X Publication Date:

More information

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency PATENT PENDING By Easy Gripper product range #94060 Easy Gripper #94095 Easy Gripper Compact Accessories Improve SAFETY and efficiency STANDARD OPTIONAL Your Easy Gripper Contact us to find out which Easy

More information