Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

Size: px
Start display at page:

Download "Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd."

Transcription

1 Stainless Steel Orifice Plate Flow Data In this flow data manual we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise. Herz Valves UK Ltd. Herz Valves UK Ltd. 00 Fax: Website:

2 Technical Data HERZ-Stainless steel orifice plate PN The flow rate can be calculated using the K vs value and a measured signal. March 00 Issue Installation K v = Q K vs = Q P Ps where Kv &Kvs = flow coefficient (m 3 /hr at bar differential) Q = flow rate (m 3 /hr) P = headloss attributable to valve (bar) Ps = differential press across tappings (signal) (bar) Size DN5 DN0 DN00 DN5 DN50 DN00 K vs Values K vs Size DN50 DN0 K vs The pressure loss across the orifice plate can be determined by multiplying the signal by the pressure loss factor. Pressure Loss The pressure loss is always less than measured signal. Size DN5 DN0 DN00 DN5 DN50 DN00 Factor Pressure Loss Factors Size DN50 DN0 Factor Under the Pressure Equipment Directive (PED) these orifice plates have been specified for Group Liquids i.e. non hazardous Sizes DN50 to DN0 are classified as SEP PED Categorisation Herz Valves UK Ltd.

3 Technical Data HERZ-Stainless steel orifice plate PN Orifice Plates can be installed in isolation or close coupled to a globe double regulating valve complying to BS 7350, of the same nominal diameter. March 00 Issue Installation Regardless of installation there must always be a minimum of 5 pipe diameters of straight pipe, without intrusion, upstream of the orifice plate. When used in isolation a minimum of pipe diameters of straight pipe are required downstream of the orifice plate. When close coupled to a double regulating valve no straight pipe is required after the valve. When used in conjunction with a butterfly double regulating valve, a spool piece equivalent to a minimum of pipe diameters is required between the orifice plate and butterfly valve. For more detailed instructions please refer to the Installation, Operation and Maintenance Instructions supplied with the orifice plate. 5D 3D 5D 5D D Once the required flow rate has been calculated, the size of the orifice plate can be determined based on the following: The minimum signal at the design flow rate of kpa. For minimum pressure loss, a maximum signal of.7 kpa, which corresponds to the maximum differential pressure range of a flurocarbon manometer. Sizing Herz Valves UK Ltd.

4 Art. HV70-07 Dim. DN5 0 0 Kvs =

5 Art. HV70-0 Dim. DN0 0 0 Kvs =

6 Art. HV70-09 Dim. DN Kvs =

7 Art. HV70-0 Dim. DN5 0 0 Kvs =

8 Art. HV70 - Dim. DN Kvs =

9 Art. HV70 - Dim. DN Kvs =

10 Art. HV70-3 Dim. DN Kvs =

11 Art. HV70 - Dim. DN0 0 0 Kvs =

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals 1. Sensor Principles with the flow sensor example 2. The typical manipulated variable: flow through a conduit Sensors: We need them

More information

Experiment (4): Flow measurement

Experiment (4): Flow measurement Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time

More information

V-Cone Flowmeter DATASHEET

V-Cone Flowmeter DATASHEET V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation

More information

Laboratory work No 2: Calibration of Orifice Flow Meter

Laboratory work No 2: Calibration of Orifice Flow Meter Laboratory work No : Calibration of Orifice Flow Meter 1. Objective Calibrate the orifice flow meter and draw the graphs p = f 1 (Q) and C d = f (Re ).. Necessary equipment 1. Orifice flow meter. Measuring

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test

More information

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read

More information

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual Zürcherstrasse 70 -CH 8104 Weiningen Tel. + 41 44 750 63 63 Fax + 41 44 750 63 66 P.O. Box 155 Switzerland Email info@prescoag.com Internet : www.prescoag.com Standard Air Capacitor 10 nf / 2 kv Type CL-0N10-K201

More information

Circulation valves. An effective partner in the battle to prevent legionella.

Circulation valves. An effective partner in the battle to prevent legionella. An effective partner in the battle to prevent legionella. Installation and maintenance Each Circulation Valve is delivered with a set of instructions.. Ensure that the circulation valve is installed with

More information

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD. INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 3/8" to 4" Female BSP + 0 C + 90 C ( 60 C for 302 and 322 types ) Max Pressure : 16 Bars ( 10 bars for 301-302 types ) Specifications : Swing type Metal

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Compact Orifice FlowMeter

Compact Orifice FlowMeter Steam Data Reference Tables IM/OM/SDT Issue 1 Compact Orifice FlowMeter ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control,

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Integral V-Cone Flowmeter VD series

Integral V-Cone Flowmeter VD series TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing

More information

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION

ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION ERRATA CRANE FLOW OF FLUIDS THROUGH VALVES, FITTINGS AND PIPE TECHNICAL PAPER NO. 410 METRIC VERSION CONTACT Please address questions and possible errata to solutions@flowoffluids.com FRONT MATTER PAGE

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore. Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore Materials : Brass Page

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

Circular duct grille

Circular duct grille Dimensions B+0 A+0 A B Description is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air. The

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1) Specifications : Anti blow-out stem PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore Materials

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

98 Series Backpressure Regulators and Relief Valves

98 Series Backpressure Regulators and Relief Valves 9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valve Type TUB/TUBE and TUC/TUCE REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Thermostatic expansion valve Type B/BE and C/CE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH Submitted By: ABDULLAH IBN ABDULRAHMAN ID: 13456789 GROUP A EXPERIMENT PERFORMED

More information

Model Selection 1. Process Valves

Model Selection 1. Process Valves Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas

More information

Hydraulics and hydrology

Hydraulics and hydrology Hydraulics and hydrology - project exercises - Class 4 and 5 Pipe flow Discharge (Q) (called also as the volume flow rate) is the volume of fluid that passes through an area per unit time. The discharge

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars up to DN1 1/2, 16 bars over Specifications : Before or after water meter

More information

EPIV electronic pressure-independent characterised control valve EPIV

EPIV electronic pressure-independent characterised control valve EPIV electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve

More information

Accumulators Virginia KMP Suction Line Accumulators

Accumulators Virginia KMP Suction Line Accumulators Accumulators Virginia KMP Suction Line Accumulators The Virginia KMP suction line accumulator's purpose is to prevent excessive quantities of liquid refrigerant and oil from returning to the compressor.

More information

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish

Smart DP Flow Metering A summary of Established Technology and Latest Innovation. Gary Fish Smart DP Flow Metering A summary of Established Technology and Latest Innovation Gary Fish DP Flow Measurement Established Technology Large range of line sizes, materials, connection interfaces, etc Customised

More information

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS Gianalberto Grego, Fabio F. Muciaccia W.E.S.T. Srl, Milan, Italy west-hydro@libero.it ABSTRACT The

More information

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct. Dimensions B+0 A+0 A B Description RGS is a rectangular ventilation grille with vertical adjustable bars for direct installation in circular ducts. The grille can be used for both supply and exhaust air.

More information

1.060 Engineering Mechanics II Spring Problem Set 4

1.060 Engineering Mechanics II Spring Problem Set 4 1.060 Engineering Mechanics II Spring 2006 Due on Monday, March 20th Problem Set 4 Important note: Please start a new sheet of paper for each problem in the problem set. Write the names of the group members

More information

Lecture 13 Flow Measurement in Pipes. I. Introduction

Lecture 13 Flow Measurement in Pipes. I. Introduction Lecture 13 Flow Measurement in Pipes I. Introduction There are a wide variety of methods for measuring discharge and velocity in pipes, or closed conduits Many of these methods can provide very accurate

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 /way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can

More information

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems

Three-Way Mixing Valve. with or without presetting, for heating and cooling systems with or without presetting, for heating and cooling systems escription HEIMEIER three-way, with or without presetting, for mixing volume flows in heating and cooling systems, made of gunmetal, with protection

More information

Experiment No.4: Flow through Venturi meter. Background and Theory

Experiment No.4: Flow through Venturi meter. Background and Theory Experiment No.4: Flow through Venturi meter Background and Theory Introduction Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters

More information

G-FIRE FLANGE ADAPTERS

G-FIRE FLANGE ADAPTERS G-FIRE FLANGE ADAPTERS 21 G-FIRE FLANGE ADAPTERS Pictorial Table of Contents MATERIAL SPECIFICATIONS Issue 03, 04, 07 Cert No. 570, 669, 673 For detailed Listing and Approval information see pages 101-10

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

SF6 Gas Standard Capacitors

SF6 Gas Standard Capacitors TYL series SF6 Gas Standard Capacitors levels up to 95% without condensation. We use special stainless steel to permit the prefect temperature and voltage coefficient stability. The capacitor is provided

More information

Thermostatic expansion valves TUB/TUBE and TUC/TUCE

Thermostatic expansion valves TUB/TUBE and TUC/TUCE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves B/BE and C/CE www.danfoss.com Thermostatic expansion valve, type B/BE and C/CE Contents Page Introduction........................................................................................

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

Schlüter -KERDI-SHOWER. System components for floor level showers

Schlüter -KERDI-SHOWER. System components for floor level showers Schlüter -KERDI-SOWER System components for floor level showers Schlüter -KERDI-SOWER Schlüter -KERDI-SOWER is a modular system for the construction of floor level showers with ceramic and stone tiles.

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces

More information

Application of Density Meters to Liquid Hydrocarbon Measurement

Application of Density Meters to Liquid Hydrocarbon Measurement 02/2018 Application of Density Meters to Liquid Hydrocarbon Measurement Written by Dean Minehart, Micro Motion, Inc. www.emerson.com/micromotion 1 Introduction The American Petroleum Institute (API) Manual

More information

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with

More information

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma)

SAMPLE SHEET. Supply of PF Process Calculation Spreadsheet (Excel Forma) PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 Supply of PF Process Calculation Spreadsheet (Excel Forma) DOCUMENT TITLE Small Bore Orifice Sizing Calculation For Gas Services as per ASME-MFC-14M-2001 DATE

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Thermostatic expansion valves TUA/TUAE

Thermostatic expansion valves TUA/TUAE MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves A/AE www.danfoss.com Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range...

More information

Instruction Manual. Equipment for Engineering Education

Instruction Manual. Equipment for Engineering Education Equipment for Engineering Education Instruction Manual HM15007 Bernoulli s Principle Demonstrator GUNT Gerätebau GmbH PO Box 1125 D-22881 Barsbüttel Germany Phone (040) 670854-0 Fax (040) 670854-42 Instruction

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 25 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Study of the accuracy of ultrasonic flowmeters for liquid

Study of the accuracy of ultrasonic flowmeters for liquid Available online at www.sciencedirect.com AASRI Procedia 3 (2012 ) 14 20 2012 AASRI Conference on Modelling, Identification and Control Study of the accuracy of ultrasonic flowmeters for liquid Liling

More information

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE COURSE TITLE : FLUID MECHANICS COURSE CODE : 307 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE MODULE TOPIC PERIOD 1 Properties of Fluids 0 Fluid Friction and Flow

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

Electronic pressure-independent characterised control valve EPIV

Electronic pressure-independent characterised control valve EPIV Electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve

More information

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, FLUID MECHANICS LABORATORY MANUAL

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, FLUID MECHANICS LABORATORY MANUAL MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, AURANGABAD. (M.S.) DEPARTMENT OF CIVIL ENGINEERING FLUID MECHANICS LABORATORY MANUAL Prepared By Mr. L. K. Kokate Lab Incharge Approved By

More information

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA WAFER TYPE BUTTERFY VAVE Z TECNICA DATA Nominal diameter: Face-to-face: EN Series (DIN T 1) ISO Series API 09 Table 1 BS 1 Series NF E 9-.1 Flange accomotion: DIN 1 PN Top flange: prepared for EN ISO Marking:

More information

CV3000 Series. Characterized Insert Control Valves

CV3000 Series. Characterized Insert Control Valves CV3000 Series Characterized Insert Control Valves The CV3000 Series is a v-type control valve for precise control allowing high pressure drop capability with straight-through flow and bubble-tight shut

More information

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES DETA FOWMETER FOR GAS SERVICE (INSERTION TYPE) MODE VF SERIES GENERA SPECIFICATION GS. No. GBD0-0-E GENERA In the thermistor type Delta meter, a probe inserted in the pipeline detects the representative

More information

Pressure independent balancing and control valve AB QM DN

Pressure independent balancing and control valve AB QM DN Data sheet Pressure independent balancing and control valve AB QM DN 10-250 The AB QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

P & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0)

P & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0) ump Sizing & Rating USER MANUAL & I Design Limited Reed Street, Gladstone Industrial Estate, Thornaby, TS7 7AF. Tel: +44 (0) 64 67444 Fax: +44 (0) 64 66447 www.pidesign.co.uk Support: sales@pidesign.co.uk

More information

2.3 T 214-A TECHNICAL DATA

2.3 T 214-A TECHNICAL DATA -INED BUTTERFY VAVE T -A ug type valve for corrosive and aggressive media. The patented shaft seal design ensures reliability even with high-corrosive applications. TECNICA DATA Nominal diameter: 0 Face-to-face:

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA ug type butterfly valve in double-eccentric construction. Reliable sealing even with extreme temperature and pressure conditions. TECHNICA DATA Nominal diameter: 0 larger nominal diameter on request Face-to-face:

More information

PRO-CLEAN STRATIFIED TANK

PRO-CLEAN STRATIFIED TANK PO-CLEAN STATIFIED TANK PODUCT DESCIPTION Pro-Clean stratified tank with spherical exchanger connection High-quality, multifunctional stratified tank made of steel (S J) for hot-water operation and domestic

More information

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS 1. INTRODUCTION Through use of the Flow-Measuring Apparatus, this experiment is designed to accustom students to typical methods

More information

Contents. Diaphragm in pressure pipe: Steady state head loss evolution and transient phenomena. Nicolas J. Adam Giovanni De Cesare

Contents. Diaphragm in pressure pipe: Steady state head loss evolution and transient phenomena. Nicolas J. Adam Giovanni De Cesare Diaphragm in pressure pipe: Steady state head loss evolution and transient phenomena Nicolas J. Adam Giovanni De Cesare Contents Introduction FMHL pumped-storage plant Experimental set-up Steady head losses

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise? The Expansibility Factor Equations in ISO 567-2 and ISO 567-4: Do They Deliver What They Promise? Michael Reader-Harris, NEL INTRODUCTION The expansibility factor equations in ISO 567-2:2003 [] and ISO

More information

CNG Trunnion Ball valve of class 0 Of BMT Co. Ltd. Make

CNG Trunnion Ball valve of class 0 Of BMT Co. Ltd. Make Mobilität Documents regarding Approval of CNG Trunnion Ball valve of class 0 Of BMT Co. Ltd. Make Approval number: E4-110R-000308-00 Report No: IN110-A0-120035 Dated 16-July-2012 Name of technical service

More information

Low Differential Pressure Gage

Low Differential Pressure Gage Low Differential Pressure Gage NEW Manostar Gage Panel installation compact type Low Differential Pressure Gage RoHS compliant Utility model registration No.2027772 Compact and lightweight type Even when

More information

Edward C. Robison, PE, SE. 02 January Architectural Metal Works ATTN: Sean Wentworth th ST Emeryville, CA 94608

Edward C. Robison, PE, SE. 02 January Architectural Metal Works ATTN: Sean Wentworth th ST Emeryville, CA 94608 Edward C. Robison, PE, SE ks ATTN: Sean Wentworth 1483 67 th ST Emeryville, CA 94608 02 January 2013 SUBJ: 501 CORTE MADERA AVE, CORTE MADERA, CA 94925 BALCONY GUARD BASE PLATE MOUNTS The guards for the

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA HIGH-PERFORMANCE BUTTERFY VAVE HP 111 Wafer type butterfly valve in double-eccentric construction. Reliable sealing even with extreme temperature and pressure conditions. TECHNICA DATA Nominal diameter:

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS

MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS MONITOR REGULATOR SIZING AND OTHER CONSIDERATIONS 6" 4" 6" 4" 4" 8" 4" 6" 6" 8" 6" 6" OGA 015 Regulator Fundamentals Seminar Monitor Regulator Sizing Theory FLOW in m out USTREAM MONITOR REGULATOR DOWNSTREAM

More information

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2 Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with

More information

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In St Andrews, Scotland From the 26 th to 28 th October, 2004 Tests of the V-Cone Flow Meter at Southwest Research Institute and Utah State University in Accordance

More information

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Vortex flow meter. SVxxx / / 2015 Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating

More information

Cipriani Harrison Valves Corp.

Cipriani Harrison Valves Corp. Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle

More information