Chapter 14: Inductor design
|
|
- Erika Atkinson
- 6 years ago
- Views:
Transcription
1 Chapter 14 Inductor Design 14.1 Filter inductor design constraints 14.2 A step-by-step design procedure 14.3 Multiple-winding magnetics design using the K g method 14.4 Examples 14.5 Summary of key points 1
2 14.1 Filter inductor design constraints Objective: i L R Design inductor having a given inductance L, which carries worst-case current I max without saturating, and which has a given winding resistance R, or, equivalently, exhibits a worst-case copper loss of P cu = I rms 2 R Example: filter inductor in CCM buck converter L i i I i L + 0 DT s T s t 2
3 Assumed filter inductor geometry Core reluctance R c Φ i + n v turns Air gap reluctance ni + R g F c + R c Φ R g R c = R g = l c µ c A c l g µ 0 A c Solve magnetic circuit: ni = Φ R c + R g Usually R c < R g and hence ni ΦR g 3
4 Constraint: maximum flux density Given a peak winding current I max, it is desired to operate the core flux density at a peak value B max. The value of B max is chosen to be less than the worst-case saturation flux density B sat of the core material. From solution of magnetic circuit: ni = BA c R g Let I = I max and B = B max : ni max = B max A c R g = B max l g µ 0 This is constraint #1. The turns ratio n and air gap length l g are unknown. 4
5 Constraint: inductance Must obtain specified inductance L. We know that the inductance is L = n2 R g = µ 0A c n 2 l g This is constraint #2. The turns ratio n, core area A c, and air gap length l g are unknown. 5
6 Constraint: winding area Wire must fit through core window (i.e., hole in center of core) core Total area of copper in window: na W Area available for winding conductors: wire bare area A W core window area W A K u W A Third design constraint: K u W A na W 6
7 The window utilization factor K u also called the fill factor K u is the fraction of the core window area that is filled by copper Mechanisms that cause K u to be less than 1: Round wire does not pack perfectly, which reduces K u by a factor of 0.7 to 0.55 depending on winding technique Insulation reduces K u by a factor of 0.95 to 0.65, depending on wire size and type of insulation Bobbin uses some window area Additional insulation may be required between windings Typical values of K u : 0.5 for simple low-voltage inductor 0.25 to 0.3 for off-line transformer 0.05 to 0.2 for high-voltage transformer (multiple kv) 0.65 for low-voltage foil-winding inductor 7
8 Winding resistance The resistance of the winding is R = ρ l b A W where is the resistivity of the conductor material, l b is the length of the wire, and A W is the wire bare area. The resistivity of copper at room temperature is cm. The length of the wire comprising an n-turn winding can be expressed as l b = n (MLT) where (MLT) is the mean-length-per-turn of the winding. The meanlength-per-turn is a function of the core geometry. The above equations can be combined to obtain the fourth constraint: R = ρ n (MLT) A W 8
9 The core geometrical constant K g The four constraints: ni max = B max A c R g = B max l g µ 0 L = n2 R g = µ 0A c n 2 l g K u W A na W R = ρ n (MLT) A W These equations involve the quantities A c, W A, and MLT, which are functions of the core geometry, I max, B max, µ 0, L, K u, R, and, which are given specifications or other known quantities, and n, l g, and A W, which are unknowns. Eliminate the three unknowns, leading to a single equation involving the remaining quantities. 9
10 Core geometrical constant K g Elimination of n, l g, and A W leads to A 2 c W A (MLT) ρl2 2 I max 2 B max RK u Right-hand side: specifications or other known quantities Left-hand side: function of only core geometry So we must choose a core whose geometry satisfies the above equation. The core geometrical constant K g is defined as K g = A c 2 W A (MLT) 10
11 Discussion K g = A 2 cw A (MLT) ρl2 2 I max 2 B max RK u K g is a figure-of-merit that describes the effective electrical size of magnetic cores, in applications where the following quantities are specified: Copper loss Maximum flux density How specifications affect the core size: A smaller core can be used by increasing B max use core material having higher B sat R allow more copper loss How the core geometry affects electrical capabilities: A larger K g can be obtained by increase of A c more iron core material, or W A larger window and more copper 11
12 14.2 A step-by-step procedure The following quantities are specified, using the units noted: Wire resistivity ( -cm) Peak winding current I max (A) Inductance L (H) Winding resistance R ( ) Winding fill factor K u Core maximum flux density B max (T) The core dimensions are expressed in cm: Core cross-sectional area A c (cm 2 ) Core window area W A (cm 2 ) Mean length per turn MLT (cm) The use of centimeters rather than meters requires that appropriate factors be added to the design equations. 12
13 Determine core size K g ρl2 2 I max (cm 5 ) RK u B max Choose a core which is large enough to satisfy this inequality (see Appendix D for magnetics design tables). Note the values of A c, W A, and MLT for this core. 13
14 Determine air gap length l g = µ 2 0LI max A c B max (m) with A c expressed in cm 2. µ 0 = H/m. The air gap length is given in meters. The value expressed above is approximate, and neglects fringing flux and other nonidealities. 14
15 A L Core manufacturers sell gapped cores. Rather than specifying the air gap length, the equivalent quantity A L is used. A L is equal to the inductance, in mh, obtained with a winding of 1000 turns. When A L is specified, it is the core manufacturer s responsibility to obtain the correct gap length. The required A L is given by: A L = 10B 2 max 2 (mh/1000 turns) LI max L = A L n A c 2 (Henries) Units: A c cm 2, L Henries, B max Tesla. 15
16 Determine number of turns n n = LI max B max A c
17 Evaluate wire size A W K uw A n (cm 2 ) Select wire with bare copper area A W less than or equal to this value. An American Wire Gauge table is included in Appendix D. As a check, the winding resistance can be computed: R = ρn (MLT) A w (Ω) 17
18 14.3 Multiple-winding magnetics design using the K g method The K g design method can be extended to multiplewinding magnetic elements such as transformers and coupled inductors. This method is applicable when Copper loss dominates the total loss (i.e. core loss is ignored), or The maximum flux density B max is a specification rather than a quantity to be optimized To do this, we must Find how to allocate the window area between the windings Generalize the step-by-step design procedure 18
19 Window area allocation Given: application with k windings having known rms currents and desired turns ratios v 1 n 1 = v 2 n 2 = = v k n k rms current I 1 n 1 : n 2 rms current I 2 Core Window area W A Core mean length per turn (MLT) Wire resistivity ρ Fill factor K u : n k rms current I k Q: how should the window area W A be allocated among the windings? 19
20 Allocation of winding area Winding 1 allocation α 1 W A Winding 2 allocation α 2 W A etc. { { Total window area W A 0<α j <1 α 1 + α α k =1 20
21 Copper loss in winding j Copper loss (not accounting for proximity loss) is P cu, j = I j 2 R j Resistance of winding j is R j = ρ l j A W,j with l j = n j (MLT) A W, j = W AK u α j n j length of wire, winding j wire area, winding j Hence R j = ρ n2 j (MLT) W A K u α j P cu,j = n j 2 i j 2 ρ(mlt) W A K u α j 21
22 Total copper loss of transformer Sum previous expression over all windings: P cu,tot = P cu,1 + P cu,2 + + P cu,k = ρ (MLT) W A K u k Σj =1 n 2 2 j I j α j Need to select values for 1, 2,, k such that the total copper loss is minimized 22
23 Variation of copper losses with 1 Copper loss Pcu,1 P cu,tot P cu,2 + P cu, P cu,k For 1 = 0: wire of winding 1 has zero area. P cu,1 tends to infinity For 1 = 1: wires of remaining windings have zero area. Their copper losses tend to infinity 0 1 α 1 There is a choice of 1 that minimizes the total copper loss 23
24 Method of Lagrange multipliers to minimize total copper loss Minimize the function P cu,tot = P cu,1 + P cu,2 + + P cu,k = ρ (MLT) W A K u k Σj =1 n 2 2 j I j α j subject to the constraint α 1 + α α k =1 Define the function where f (α 1, α 2,, α k, ξ)=p cu,tot (α 1, α 2,, α k )+ξ g(α 1, α 2,, α k ) g(α 1, α 2,, α k )=1 α j Σj =1 is the constraint that must equal zero and is the Lagrange multiplier k 24
25 Lagrange multipliers continued Optimum point is solution of the system of equations f (α 1, α 2, α 1, α k,ξ) =0 f (α 1, α 2, α 2, α k,ξ) =0 Result: ξ = ρ (MLT) W A K u α m = n mi m Σ n j I j n =1 k Σj =1 n j I j 2 = P cu,tot f (α 1, α 2, α k, α k,ξ) =0 f (α 1, α 2, ξ, α k,ξ) =0 An alternate form: α m = V mi m Σ V j I j n =1 25
26 Interpretation of result α m = V mi m Σ V j I j n =1 Apparent power in winding j is where V j I j V j is the rms or peak applied voltage I j is the rms current Window area should be allocated according to the apparent powers of the windings 26
27 Example PWM full-bridge transformer i 1 i 2 I n 1 turns { } n 2 turns } n 2 turns i 1 n 2 n 1 I i Note that waveshapes (and hence rms values) of the primary and secondary currents are different Treat as a threewinding transformer i 2 i 3 I 0 n 2 n 1 I 0.5I 0.5I 0 I 0.5I 0.5I 0 DT s T s T s +DT s 2T s t 27
28 Expressions for RMS winding currents i 1 n 2 n 1 I I 1 = 1 2Ts I 2 = I 3 = 1 2Ts see Appendix A 0 2T s i 2 1 dt = n 2 I n 1 0 D 2T s i 2 2 dt = 1 2 I 1+D i 2 i 3 I n 2 n 1 I 0.5I 0.5I 0 I 0.5I 0.5I 0 DT s T s T s +DT s 2T s t 28
29 Allocation of window area: α m = V mi m Σ V j I j n =1 Plug in rms current expressions. Result: α 1 = D D Fraction of window area allocated to primary winding α 2 = α 3 = D 1+D Fraction of window area allocated to each secondary winding 29
30 Numerical example Suppose that we decide to optimize the transformer design at the worst-case operating point D = Then we obtain α 1 = α 2 = α 3 = The total copper loss is then given by P cu,tot = ρ(mlt) W A K u 3 Σj =1 n j I j 2 = ρ(mlt)n 2 2 I 2 W A K u 1+2D +2 D(1 + D) 30
31 Coupled inductor design constraints Consider now the design of a coupled inductor having k windings. We want to obtain a specified value of magnetizing inductance, with specified turns ratios and total copper loss. i 1 + v 1 i M L M n 1 : n 2 + v 2 i 2 Magnetic circuit model: R c R 1 R 2 n 1 i M + Φ R g + v k i k : n k R k 31
32 14.4 Examples Coupled Inductor for a Two-Output Forward Converter CCM Flyback Transformer 32
33 Example 2: CCM flyback transformer i M Transformer model I M i M V g i 1 i M + L M + v M n 1 : n 2 D 1 i 2 C R + V 0 i 1 I M 0 i 2 Q 1 n 1 n 2 I M 0 v M V g 0 DT s 33
34 Specifications Input voltage V g = 200V Output (full load) 20 V at 5 A Switching frequency 150 khz Magnetizing current ripple 20% of dc magnetizing current Duty cycle D = 0.4 Turns ratio n 2 /n 1 = 0.15 Copper loss 1.5 W Fill factor K u = 0.3 Maximum flux density B max = 0.25 T 34
35 Basic converter calculations Components of magnetizing current, referred to primary: I M = n 2 n 1 1 D V R = 1.25 A RMS winding currents: I 1 = I M D i M I M 2 = A i M = 20% I M = 0.25 A I 2 = n 1 n 2 I M D i M I M 2 = 6.50 A I M,max = I M + i M = 1.5 A Choose magnetizing inductance: I tot = I 1 + n 2 n 1 I 2 = 1.77 A L M = V g DT s 2 i M = 1.07 mh 35
36 Choose core size K g ρl 2 MI 2 2 tot I M,max P cu K u B max = Ω-cm H A A 2 = cm T W The smallest EE core that satisfies this inequality (Appendix D) is the EE30. 36
37 Choose air gap and turns l g = µ 2 0L M I M,max A c B max = 4π 10 7 H/m H 1.5 A T cm =0.44mm n 1 = L MI M,max B max A c 10 4 = H 1.5 A 0.25 T 1.09 cm = 58.7 turns Round to n 1 =59 37 n 2 = n 2 n 1 n 1 = = 8.81 n 2 =9
38 Wire gauges α 1 = I 1 I tot = A 1.77 A = 0.45 α 2 = n 2I 2 n 1 I tot = A A = 0.55 A W1 α 1K u W A n 1 = cm 2 use #28 AWG A W2 α 2K u W A n 2 = cm 2 use #19 AWG 38
39 Core loss CCM flyback example B-H loop for this application: B The relevant waveforms: B B sat B max B B max B V g H c Minor B H loop, CCM flyback example 0 v M 0 n 1 A c V g DT s B H loop, large excitation B vs. applied voltage, from Faraday s law: db dt = v M n 1 A c For the first subinterval: db dt = V g n 1 A c 39
40 Calculation of ac flux density and core loss Solve for B: B = V g n 1 A c DT s Plug in values for flyback example: 200 V µs B = cm 2 =0.041 T From manufacturer s plot of core loss (at left), the power loss density is 0.04 W/cm 3. Hence core loss is P fe = 0.04 W/cm 3 A c l m = 0.04 W/cm cm cm = 0.25 W 40 Power loss density, Watts/cm W/cm 3 400kHz 200kHz 150kHz 100kHz 50kHz 20kHz B, Tesla
41 Comparison of core and copper loss Copper loss is 1.5 W does not include proximity losses, which could substantially increase total copper loss Core loss is 0.25 W Core loss is small because ripple and B are small It is not a bad approximation to ignore core losses for ferrite in CCM filter inductors Could consider use of a less expensive core material having higher core loss Neglecting core loss is a reasonable approximation for this application Design is dominated by copper loss The dominant constraint on flux density is saturation of the core, rather than core loss 41
42 14.5 Summary of key points 1. A variety of magnetic devices are commonly used in switching converters. These devices differ in their core flux density variations, as well as in the magnitudes of the ac winding currents. When the flux density variations are small, core loss can be neglected. Alternatively, a low-frequency material can be used, having higher saturation flux density. 2. The core geometrical constant K g is a measure of the magnetic size of a core, for applications in which copper loss is dominant. In the K g design method, flux density and total copper loss are specified. 42
R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder Chapter 14 Inductor Design 14.1 Filter inductor design constraints 14.2 A step-by-step design procedure
More information15.1 Transformer Design: Basic Constraints. Chapter 15: Transformer design. Chapter 15 Transformer Design
Chapter 5 Transformer Design Some more advanced design issues, not considered in previous chapter: : n Inclusion of core loss Selection of operating flux density to optimize total loss Multiple winding
More informationIn The Name of GOD. Switched Mode Power Supply
In The Name of GOD Switched Mode Power Supply Switched Mode Power Supply Lecture 9 Inductor Design Φ Adib Abrishamifar EE Department IUST Outline } Types of magnetic devices } Filter inductor } Ac inductor
More informationR. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder 15.3.2 Example 2 Multiple-Output Full-Bridge Buck Converter Q 1 D 1 Q 3 D 3 + T 1 : : n 2 D 5 i
More informationPart III. Magnetics. Chapter 13: Basic Magnetics Theory. Chapter 13 Basic Magnetics Theory
Part III. Magnetics 3 Basic Magnetics Theory Inductor Design 5 Transformer Design Chapter 3 Basic Magnetics Theory 3. Review of Basic Magnetics 3.. Basic relationships 3..2 Magnetic circuits 3.2 Transformer
More informationR. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
R. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder Part III. Magnetics 13 Basic Magnetics Theory 14 Inductor Design 15 Transformer Design 1 Chapter
More information6.3. Transformer isolation
6.3. Transformer isolation Objectives: Isolation of input and output ground connections, to meet safety requirements eduction of transformer size by incorporating high frequency isolation transformer inside
More informationSection 8: Magnetic Components
Section 8: Magnetic omponents Inductors and transformers used in power electronic converters operate at quite high frequency. The operating frequency is in khz to MHz. Magnetic transformer steel which
More informationSwitched Mode Power Conversion
Inductors Devices for Efficient Power Conversion Switches Inductors Transformers Capacitors Inductors Inductors Store Energy Inductors Store Energy in a Magnetic Field In Power Converters Energy Storage
More informationElements of Power Electronics PART I: Bases
Elements of Power Electronics PART I: Bases Fabrice Frébel (fabrice.frebel@ulg.ac.be) September 21 st, 2017 Goal and expectations The goal of the course is to provide a toolbox that allows you to: understand
More informationR. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder 2.4 Cuk converter example L 1 C 1 L 2 Cuk converter, with ideal switch i 1 i v 1 2 1 2 C 2 v 2 Cuk
More informationChapter 3. Steady-State Equivalent Circuit Modeling, Losses, and Efficiency
Chapter 3. Steady-State Equivalent Circuit Modeling, Losses, and Efficiency 3.1. The dc transformer model 3.2. Inclusion of inductor copper loss 3.3. Construction of equivalent circuit model 3.4. How to
More informationSwitched Mode Power Conversion Prof. L. Umanand Department of Electronics System Engineering Indian Institute of Science, Bangalore
Switched Mode Power Conversion Prof. L. Umanand Department of Electronics System Engineering Indian Institute of Science, Bangalore Lecture - 39 Magnetic Design Good day to all of you. Today, we shall
More informationLecture 17 Push-Pull and Bridge DC-DC converters Push-Pull Converter (Buck Derived) Centre-tapped primary and secondary windings
ecture 17 Push-Pull and Bridge DC-DC converters Push-Pull Converter (Buck Derived) Centre-tapped primary and secondary windings 1 2 D 1 i v 1 v 1s + v C o R v 2 v 2s d 1 2 T 1 T 2 D 2 Figure 17.1 v c (
More informationChapter 1 Magnetic Circuits
Principles of Electric Machines and Power Electronics Third Edition P. C. Sen Chapter 1 Magnetic Circuits Chapter 1: Main contents i-h relation, B-H relation Magnetic circuit and analysis Property of magnetic
More informationET4119 Electronic Power Conversion 2011/2012 Solutions 27 January 2012
ET4119 Electronic Power Conversion 2011/2012 Solutions 27 January 2012 1. In the single-phase rectifier shown below in Fig 1a., s = 1mH and I d = 10A. The input voltage v s has the pulse waveform shown
More informationReview of Basic Electrical and Magnetic Circuit Concepts EE
Review of Basic Electrical and Magnetic Circuit Concepts EE 442-642 Sinusoidal Linear Circuits: Instantaneous voltage, current and power, rms values Average (real) power, reactive power, apparent power,
More informationAnalysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method
J. Electromagnetic Analysis & Applications, 010,, 67-63 doi:10.436/emaa.010.1108 ublished Online November 010 (http://www.scirp.org/ournal/emaa) Analysis of Thermal Behavior of High Frequency Transformers
More informationELECTRO MAGNETIC INDUCTION
ELECTRO MAGNETIC INDUCTION 1) A Circular coil is placed near a current carrying conductor. The induced current is anti clock wise when the coil is, 1. Stationary 2. Moved away from the conductor 3. Moved
More informationLecture Set 1 Introduction to Magnetic Circuits
Lecture Set 1 Introduction to Magnetic Circuits S.D. Sudhoff Spring 2017 1 Goals Review physical laws pertaining to analysis of magnetic systems Introduce concept of magnetic circuit as means to obtain
More informationForce and Displacement Measurement
Force and Displacement Measurement Prof. R.G. Longoria Updated Fall 20 Simple ways to measure a force http://scienceblogs.com/dotphysics/200/02/diy_force_probe.php Example: Key Force/Deflection measure
More informationChapter 15 Magnetic Circuits and Transformers
Chapter 15 Magnetic Circuits and Transformers Chapter 15 Magnetic Circuits and Transformers 1. Understand magnetic fields and their interactio with moving charges. 2. Use the right-hand rule to determine
More informationChapter 21. Derivations for the Design Equations
Chapter 21 Derivations for the Design Equations The author would like to thank Richard Ozenbaugh of Linear Magnetics for his help with the derivations. Table of Contents 1. Output Power, P 0, Versus Apparent
More informationLecture 30: WED 04 NOV
Physics 2113 Jonathan Dowling Lecture 30: WED 04 NOV Induction and Inductance II Fender Stratocaster Solenoid Pickup F a r a d a y ' s E x p e r i m e n t s I n a s e r i e s o f e x p e r i m e n t s,
More informationChapter 11 AC and DC Equivalent Circuit Modeling of the Discontinuous Conduction Mode
Chapter 11 AC and DC Equivalent Circuit Modeling of the Discontinuous Conduction Mode Introduction 11.1. DCM Averaged Switch Model 11.2. Small-Signal AC Modeling of the DCM Switch Network 11.3. High-Frequency
More informationLecture 24. April 5 th, Magnetic Circuits & Inductance
Lecture 24 April 5 th, 2005 Magnetic Circuits & Inductance Reading: Boylestad s Circuit Analysis, 3 rd Canadian Edition Chapter 11.1-11.5, Pages 331-338 Chapter 12.1-12.4, Pages 341-349 Chapter 12.7-12.9,
More informationMutual Inductance: This is the magnetic flux coupling of 2 coils where the current in one coil causes a voltage to be induced in the other coil.
agnetically Coupled Circuits utual Inductance: This is the magnetic flux coupling of coils where the current in one coil causes a voltage to be induced in the other coil. st I d like to emphasize that
More informationScheme I SAMPLE QUESTION PAPER I
SAMPLE QUESTION PAPER I Marks : 70 Time: 3 Hours Q.1) A) Attempt any FIVE of the following. a) Define active components. b) List different types of resistors. c) Describe method to test following passive
More informationReactor Characteristic Evaluation and Analysis Technologies of JFE Steel
JFE TECHNICAL REPORT No. 21 (Mar. 2016) Reactor Characteristic Evaluation and Analysis Technologies of HIRATANI Tatsuhiko *1 NAMIKAWA Misao *2 NISHINA Yoshiaki *3 Abstract: Reactor characteristic evaluation
More informationThe initial magnetization curve shows the magnetic flux density that would result when an increasing magnetic field is applied to an initially
MAGNETIC CIRCUITS The study of magnetic circuits is important in the study of energy systems since the operation of key components such as transformers and rotating machines (DC machines, induction machines,
More informationCross Regulation Mechanisms in Multiple-Output Forward and Flyback Converters
Cross Regulation Mechanisms in Multiple-Output Forward and Flyback Converters Bob Erickson and Dragan Maksimovic Colorado Power Electronics Center (CoPEC) University of Colorado, Boulder 80309-0425 http://ece-www.colorado.edu/~pwrelect
More informationDesign and analysis of the ferrite air-gapped cores for a resonant inductor
ARCHIVES OF ELECTRICAL ENGINEERING VOL. 67(3), pp. 579 589 (2018) DOI 10.24425/123664 Design and analysis of the ferrite air-gapped cores for a resonant inductor JIANFEN ZHENG, CHUNFANG WANG, DONGWEI XIA
More informationmagneticsp17 September 14, of 17
EXPERIMENT Magnetics Faraday s Law in Coils with Permanent Magnet, DC and AC Excitation OBJECTIVE The knowledge and understanding of the behavior of magnetic materials is of prime importance for the design
More informationPhysics 1c Practical, Spring 2015 Hw 3 Solutions
Physics 1c Practical, Spring 2015 Hw 3 Solutions April 16, 2015 1 Serway 31.79 (5 points) By Lenz s Law, current will flow in each of the two sub-loops to oppose the change in flux. One can easily see
More informationROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I
ROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR-621220 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I Unit I Introduction 1. What are the three basic types
More informationElectromagnetic Induction
Faraday s Discovery Faraday found that there is a current in a coil of wire if and only if the magnetic field passing through the coil is changing. This is an informal statement of Faraday s law. Electromagnetic
More informationCERN ACCELERATOR SCHOOL Power Converters. Passive components. Prof. Alfred Rufer
CERN ACCELERATOR SCHOOL Power Converters Passive components Prof. Alfred Rufer Overview Part 1: (to be designed) Part 2: Capacitors (to be selected) Part 3: A new component: The Supercapacitor, component
More informationChapter 7 DC-DC Switch-Mode Converters
Chapter 7 DC-DC Switch-Mode Converters dc-dc converters for switch-mode dc power supplies and dc-motor drives 7-1 Block Diagram of DC-DC Converters Functional block diagram 7-2 Stepping Down a DC Voltage
More informationEE 3324 Electromagnetics Laboratory
EE 3324 Electromagnetics Laboratory Experiment #3 Inductors and Inductance 1. Objective The objective of Experiment #3 is to investigate the concepts of inductors and inductance. Several inductor geometries
More informationR. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder Part II" Converter Dynamics and Control! 7.!AC equivalent circuit modeling! 8.!Converter transfer
More informationSuppose two uniform bars meet at an abrupt plane and there is a magnetic field induced by an extended core and coil structure off stage as in:
Class Notes Week of 1/9 /3/017 ENGN1931F The magnetic structures that are central to the design of generators, transformers, motors, inductors, solenoids, etc. can be complex. We need a way to make approximate
More informationMeasurements in Mechatronic design. Transducers
Measurements in Mechatronic design Transducers Quantities Current Voltage Torque Force Magnetic flux Distance Temperature Measurement system Physical quanties Transducer Signal conditioning Measurement
More informationTutorial Sheet Fig. Q1
Tutorial Sheet - 04 1. The magnetic circuit shown in Fig. Q1 has dimensions A c = A g = 9 cm 2, g = 0.050 cm, l c = 30 cm, and N = 500 turns. Assume the value of the relative permeability,µ r = 70,000
More informationElectromagnetic Induction & Inductors
Electromagnetic Induction & Inductors 1 Revision of Electromagnetic Induction and Inductors (Much of this material has come from Electrical & Electronic Principles & Technology by John Bird) Magnetic Field
More informationSECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM
SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM Unit Objectives Describe the structure of an atom. Identify atoms with a positive charge and atoms with a negative charge. Explain
More informationMutual Inductance. The field lines flow from a + charge to a - change
Capacitors Mutual Inductance Since electrical charges do exist, electric field lines have a starting point and an ending point. For example, if you have a + and a - change, the field lines would look something
More information9-3 Inductance. * We likewise can have self inductance, were a timevarying current in a circuit induces an emf voltage within that same circuit!
/3/004 section 9_3 Inductance / 9-3 Inductance Reading Assignment: pp. 90-86 * A transformer is an example of mutual inductance, where a time-varying current in one circuit (i.e., the primary) induces
More informationTutorial Sheet IV. Fig. IV_2.
Tutorial Sheet IV 1. Two identical inductors 1 H each are connected in series as shown. Deduce the combined inductance. If a third and then a fourth are similarly connected in series with this combined
More informationDifferent Techniques for Calculating Apparent and Incremental Inductances using Finite Element Method
Different Techniques for Calculating Apparent and Incremental Inductances using Finite Element Method Dr. Amer Mejbel Ali Electrical Engineering Department Al-Mustansiriyah University Baghdad, Iraq amerman67@yahoo.com
More informationIntroduction to AC Circuits (Capacitors and Inductors)
Introduction to AC Circuits (Capacitors and Inductors) Amin Electronics and Electrical Communications Engineering Department (EECE) Cairo University elc.n102.eng@gmail.com http://scholar.cu.edu.eg/refky/
More informationRevision Guide for Chapter 15
Revision Guide for Chapter 15 Contents tudent s Checklist Revision otes Transformer... 4 Electromagnetic induction... 4 Generator... 5 Electric motor... 6 Magnetic field... 8 Magnetic flux... 9 Force on
More information[22.1 (2)(0.42) (3.38 / 2)] At/Wb
Transformers and Inductors for Power Electronics Theory, Design and Applications p. xiii: In Hurley bio add He received the IEEE Power Electronics Society Middlebrook Award for technical achievement in
More informationPower Electronics
Prof. Dr. Ing. Joachim Böcker Power Electronics 3.09.06 Last Name: Student Number: First Name: Study Program: Professional Examination Performance Proof Task: (Credits) (0) (0) 3 (0) 4 (0) Total (80) Mark
More informationSelf-Inductance. Φ i. Self-induction. = (if flux Φ 1 through 1 loop. Tm Vs A A. Lecture 11-1
Lecture - Self-Inductance As current i through coil increases, magnetic flux through itself increases. This in turn induces back emf in the coil itself When current i is decreasing, emf is induced again
More informationModellierung von Kern- und Wicklungsverlusten Jonas Mühlethaler, Johann W. Kolar
Modellierung von Kern- und Wicklungsverlusten Jonas Mühlethaler, Johann W. Kolar Power Electronic Systems Laboratory, ETH Zurich Motivation Modeling Inductive Components Employing best state-of-the-art
More information9. Mutual Induction Theory
Mutual inductance occurs when the change in current in one inductor induces a voltage in another nearby inductor. It is the mechanism by which transformers work, but it can also cause unwanted coupling
More informationPart 4: Electromagnetism. 4.1: Induction. A. Faraday's Law. The magnetic flux through a loop of wire is
1 Part 4: Electromagnetism 4.1: Induction A. Faraday's Law The magnetic flux through a loop of wire is Φ = BA cos θ B A B = magnetic field penetrating loop [T] A = area of loop [m 2 ] = angle between field
More informationSome Important Electrical Units
Some Important Electrical Units Quantity Unit Symbol Current Charge Voltage Resistance Power Ampere Coulomb Volt Ohm Watt A C V W W These derived units are based on fundamental units from the meterkilogram-second
More informationELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT
Chapter 31: ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT 1 A charged capacitor and an inductor are connected in series At time t = 0 the current is zero, but the capacitor is charged If T is the
More informationr where the electric constant
1.0 ELECTROSTATICS At the end of this topic, students will be able to: 10 1.1 Coulomb s law a) Explain the concepts of electrons, protons, charged objects, charged up, gaining charge, losing charge, charging
More informationThermal vs. Power Loss Efficiency Considerations for Powder Core Materials. Christopher Oliver Nien Teng Micrometals, Incorporated
Thermal vs. Power Loss Efficiency Considerations for Powder Core Materials Christopher Oliver Nien Teng Micrometals, Incorporated Outline Powder Cores Description What properties change with temperature
More informationLECTURE 8 Fundamental Models of Pulse-Width Modulated DC-DC Converters: f(d)
1 ECTURE 8 Fundamental Models of Pulse-Width Modulated DC-DC Converters: f(d) I. Quasi-Static Approximation A. inear Models/ Small Signals/ Quasistatic I V C dt Amp-Sec/Farad V I dt Volt-Sec/Henry 1. Switched
More informationASSOCIATE DEGREE IN ENGINEERING RESIT EXAMINATIONS SEMESTER 1. "Electrical Eng Science"
ASSOCIATE DEGREE IN ENGINEERING RESIT EXAMINATIONS SEMESTER 1 COURSE NAME: "Electrical Eng Science" CODE: GROUP: "[ADET 2]" DATE: December 2010 TIME: DURATION: 9:00 am "Two hours" INSTRUCTIONS: 1. This
More informationElectric Circuits I. Inductors. Dr. Firas Obeidat
Electric Circuits I Inductors Dr. Firas Obeidat 1 Inductors An inductor is a passive element designed to store energy in its magnetic field. They are used in power supplies, transformers, radios, TVs,
More informationInductance, RL Circuits, LC Circuits, RLC Circuits
Inductance, R Circuits, C Circuits, RC Circuits Inductance What happens when we close the switch? The current flows What does the current look like as a function of time? Does it look like this? I t Inductance
More information3 The non-linear elements
3.1 Introduction The inductor and the capacitor are the two important passive circuit elements which have the ability to store and deliver finite amount of energy [49]. In an inductor, the energy is stored
More informationR. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder
. W. Erickson Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder 8.1.7. The low-q approximation Given a second-order denominator polynomial, of the form G(s)= 1
More information7.3 State Space Averaging!
7.3 State Space Averaging! A formal method for deriving the small-signal ac equations of a switching converter! Equivalent to the modeling method of the previous sections! Uses the state-space matrix description
More informationPart II Converter Dynamics and Control
Part II Converter Dynamics and Control 7. AC equivalent circuit modeling 8. Converter transfer functions 9. Controller design 10. Ac and dc equivalent circuit modeling of the discontinuous conduction mode
More informationTransformer. Transformer comprises two or more windings coupled by a common magnetic circuit (M.C.).
. Transformers Transformer Transformer comprises two or more windings coupled by a common magnetic circuit (M.C.). f the primary side is connected to an AC voltage source v (t), an AC flux (t) will be
More informationThe output voltage is given by,
71 The output voltage is given by, = (3.1) The inductor and capacitor values of the Boost converter are derived by having the same assumption as that of the Buck converter. Now the critical value of the
More informationSYLLABUS(EE-205-F) SECTION-B
SYLLABUS(EE-205-F) SECTION-A MAGNETIC CIRCUITS AND INDUCTION: Magnetic Circuits, Magnetic Materials and their properties, static and dynamic emfs and dforce on current carrying conductor, AC operation
More informationSolution for Fq. A. up B. down C. east D. west E. south
Solution for Fq A proton traveling due north enters a region that contains both a magnetic field and an electric field. The electric field lines point due west. It is observed that the proton continues
More informationEE155/255 Green Electronics
EE155/255 Green Electronics Electric Motors 10/19/16 Prof. William Dally Computer Systems Laboratory Stanford University This week is flipped Course Logistics Discussion on 10/17, Motors on 10/19, Isolated
More informationWLPN Series SMD Molded Power Choke Inductors
WLPN303010 Series SMD Molded Power Choke Inductors *Contents in this sheet are subject to change without prior notice. Page 1 of 9 ASC_WLPN303010 Series_V3.0 Oct. 2016 Features 1. Close magnetic loop with
More informationREVISED HIGHER PHYSICS REVISION BOOKLET ELECTRONS AND ENERGY
REVSED HGHER PHYSCS REVSON BOOKLET ELECTRONS AND ENERGY Kinross High School Monitoring and measuring a.c. Alternating current: Mains supply a.c.; batteries/cells supply d.c. Electrons moving back and forth,
More informationPhysics 1302W.400 Lecture 33 Introductory Physics for Scientists and Engineering II
Physics 1302W.400 Lecture 33 Introductory Physics for Scientists and Engineering II In today s lecture, we will discuss generators and motors. Slide 30-1 Announcement Quiz 4 will be next week. The Final
More informationEDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3. OUTCOME 3 - MAGNETISM and INDUCTION
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 3 - MAGNETISM and INDUCTION 3 Understand the principles and properties of magnetism Magnetic field:
More informationModule 7. Transformer. Version 2 EE IIT, Kharagpur
Module 7 Transformer ersion EE T, Kharagpur Lesson 5 Testing, Efficiency & Regulation ersion EE T, Kharagpur Contents 5 Testing, Efficiency & regulation 4 5. Goals of the lesson.. 4 5. Determination of
More informationElectromagnetic Induction
Chapter II Electromagnetic Induction Day 1 Induced EMF, Faraday s Law and Lenz s Law Sections 21-1 to 21-2 Electromotive Force Electromotive force (EMF ore) is a misnomer, as it is not really a force but
More informationL4970A 10A SWITCHING REGULATOR
L4970A 10A SWITCHING REGULATOR 10A OUTPUT CURRENT.1 TO 40 OUTPUT OLTAGE RANGE 0 TO 90 DUTY CYCLE RANGE INTERNAL FEED-FORWARD LINE REGULA- TION INTERNAL CURRENT LIMITING PRECISE.1 ± 2 ON CHIP REFERENCE
More informationPreliminary Sizing Design of a 1 MW Low Duty Cycle Switched Reluctance Generator for Aerospace Applications
Preliminary Sizing Design of a 1 MW Low Duty Cycle Switched Reluctance Generator for Aerospace Applications Jin-Woo Jung, Ph. D. Student Advisors: Prof. Ali Keyhani Adjunct Prof. Tomy Sebastian Oct. 25,
More informationWireless charging using a separate third winding for reactive power supply
Wireless charging using a separate third winding for reactive power supply Master s thesis in Energy and Environment IAN ŠALKOIĆ Department of Energy and Environment Division of Electric Power Engineering
More informationIEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 1, JANUARY /$ IEEE
IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 1, JANUARY 2007 195 Analysis of Half-Turn Effect in Power Transformers Using Nonlinear-Transient FE Formulation G. B. Kumbhar, S. V. Kulkarni, Member,
More informationB C E. absolute maximum ratings at 25 C ambient temperature (unless otherwise noted )
Designed Specifically for High Frequency Electronic Ballasts up to 5 W h FE 6 to at = V, = A Low Power Losses (On-state and Switching) Key Parameters Characterised at High Temperature Tight and Reproducible
More informationNR/RR. Set No. 2 CODE NO: NR/RR210204
Set No. 2 II B.Tech I Semester Examinations,May 2011 ELECTROMAGNETIC FIELDS Electrical And Electronics Engineering Time: 3 hours Max Marks: 80 Answer any FIVE Questions All Questions carry equal marks
More informationTransformer Fundamentals
Transformer Fundamentals 1 Introduction The physical basis of the transformer is mutual induction between two circuits linked by a common magnetic field. Transformer is required to pass electrical energy
More informationDefinition Application of electrical machines Electromagnetism: review Analogies between electric and magnetic circuits Faraday s Law Electromagnetic
Definition Application of electrical machines Electromagnetism: review Analogies between electric and magnetic circuits Faraday s Law Electromagnetic Force Motor action Generator action Types and parts
More informationLecture 16.1 :! Final Exam Review, Part 2
Lecture 16.1 :! Final Exam Review, Part 2 April 28, 2015 1 Announcements Online Evaluation e-mails should have been sent to you.! Please fill out the evaluation form. May 6 is deadline.! Remember that
More informationRLC Circuit (3) We can then write the differential equation for charge on the capacitor. The solution of this differential equation is
RLC Circuit (3) We can then write the differential equation for charge on the capacitor The solution of this differential equation is (damped harmonic oscillation!), where 25 RLC Circuit (4) If we charge
More informationTactics: Evaluating line integrals
Tactics: Evaluating line integrals Ampère s law Whenever total current I through passes through an area bounded by a closed curve, the line integral of the magnetic field around the curve is given by Ampère
More informationFachgebiet Leistungselektronik und Elektrische Antriebstechnik. Test Examination: Mechatronics and Electrical Drives
Prof. Dr. Ing. Joachim Böcker Test Examination: Mechatronics and Electrical Drives 8.1.214 First Name: Student number: Last Name: Course of Study: Exercise: 1 2 3 Total (Points) (2) (2) (2) (6) Duration:
More informationLecture 4: Losses and Heat Transfer
1 / 26 Lecture 4: Losses and Heat Transfer ELEC-E845 Electric Drives (5 ECTS) Marko Hinkkanen Aalto University School of Electrical Engineering Autumn 215 2 / 26 Learning Outcomes After this lecture and
More informationConventional Paper-I Part A. 1. (a) Define intrinsic wave impedance for a medium and derive the equation for intrinsic vy
EE-Conventional Paper-I IES-01 www.gateforum.com Conventional Paper-I-01 Part A 1. (a) Define intrinsic wave impedance for a medium and derive the equation for intrinsic vy impedance for a lossy dielectric
More informationLecture 15: Inductor & Capacitor
ECE 1270: Introduction to Electric Circuits 0 Lecture 15: Inductor & Capacitor Chapter 6 Inductance, Capacitance, and Mutual Inductance Sections 6.1-6.3 EE 1270: Introduction to Electric Circuits 1 Inductor
More informationModelling Non-Ideal Inductors in SPICE
Modelling Non-Ideal Inductors in SPICE Martin O'Hara Technical Manager, Newport Components, Milton Keynes November 1994 Abstract The non-ideal inductor exhibits both self resonance and non-linear current
More informationCHAPTER 8 DC MACHINERY FUNDAMENTALS
CHAPTER 8 DC MACHINERY FUNDAMENTALS Summary: 1. A Simple Rotating Loop between Curved Pole Faces - The Voltage Induced in a Rotating Loop - Getting DC voltage out of the Rotating Loop - The Induced Torque
More information5. Passive Components
5. Passive Components Inductive Elements Components - Inductors - Transformers Materials - Laminated alloys for example Silicon-steel (High poer, lo frequency, high sat ) - Iron poder (Medium poer, lo
More informationBasic Electrical Technology Prof. Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore
Basic Electrical Technology Prof. Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore Lecture - 18 Transformer Basics Part - II Hello everybody, in the last session
More informationEC Objective Paper I (Set - D)
EC-Objective Paper-I ESE-5 www.gateforum.com EC Objective Paper I (Set - D). If a system produces frequencies in the output are not present in the input, then the system cannot be Minimum phase system
More information