Report of Test LLIA R02*

Size: px
Start display at page:

Download "Report of Test LLIA R02*"

Transcription

1 eport of Test LLIA * *This test report supersedes test report LLIA Catalog Number: F-AL/0/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating lm W lm/w B4-U2-G5 Performance Summary Power Factor THD(i) Lateral Classification Vertical Classification % of Luminous Flux 0- Zone 80 - Zone Type III Medium % % 3.1 % PEPAED FO : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742, USA (issuing laboratory) Page 1 of 12 13

2 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 (issuing laboratory) Page 2 of 12 13

3 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Polar Light Distribution Curves House side / L270 L / Black, Plane of maximum - ed, L0 / Blue (cd) Street side / L Percentage Outputs Upward Downward Total Street Side 0.0 % 62.0 % 62.1 % House Side 0.0 % 37.9 % 37.9 % 0.0 % % % eport data based on absolute values as measured. Signed: Authorized Signatory Date of test Date of report 27-Jul Aug-2018 (issuing laboratory) Page 3 of 12 13

4 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Principal Vertical Plane Intensity in principal plane (based on overall max intensity) (L72.5) Vertical Intensity Angle ( ) (cd) Plane of maximum intensity (cd) House side max intensity Street side max intensity (.0, 7.5 ) (72.5, 75.0 ) Coordinates expressed in the C Type coordinate system Data for the two symmetric halves of the luminaire has been averaged (issuing laboratory) Page 4 of 12 13

5 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Intensity in principal cone (based on overall max intensity) Principal Conical Surface Lateral (V75.0) 120 Plane ( ) (cd) House side Cone of maximum intensity (cd) Street side House side max intensity Street side max intensity (.0, 7.5 ) (72.5, 75.0 ) Coordinates expressed in the C Type coordinate system Data for the two symmetric halves of the luminaire has been averaged. (issuing laboratory) Page 5 of 12 13

6 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Polar curve through L / L270 Polar curve through L0 / L (L) (cd) (L270) House side (L180) (cd) Street side (L0) (issuing laboratory) Page 6 of 12 13

7 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 8.0 Ground Plane Isocandela Diagram Distance along the road Note: The isocandela levels are based on a mounting height of H = 10.0 metres. Grid values show multiples of mounting height. House side Distance across the road Street side The isocandela contours are set to 10%, 20%, %, 50%, 70%, % of the maximum. The isocandela contour units are expressed as cd Upstream and downstream sides have been averaged. (issuing laboratory) Page 7 of 12 13

8 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 (issuing laboratory) Page 8 of 13 12

9 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Intensity data (cd) L-Plane Vertical L0 L15 L L40 L45 L50 L55 L L (issuing laboratory) Page 9 of 12 13

10 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Intensity data (cd) L-Plane Vertical L70 L75 L80 L85 L L95 L100 L105 L (issuing laboratory) Page 10 of 12 13

11 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Intensity data (cd) L-Plane Vertical L115 L120 L125 L1 L135 L140 L150 L165 L (issuing laboratory) Page 11 of 12 13

12 Test Number: LLIA Catalog Number: F AL/0/50K/S3 Circle of Light Plot Height(ft) Beam Width (across 50% Nadir Illum) Illuminance at Nadir (fc) (issuing laboratory) Page 12 of 13

13 Test eport No. LLIA Catalog Number: F-AL/0/50K/S3 Test Distance 9.5 m Test Temperature 25.6 C Notes The laboratory has not participated in the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. Tested in accordance with the applicable sections of publications: IES LM (Sec. 12), IES LM-16-93, IES LM-58-13, CIE 13.3:1995, CIE 15:2004, ANSI C78.377:2015, ANSI C :2014. The luminous intensity values, and other derived quantities, contained in this report are based on the absolute data, as measured. Prorating the performance of the sample for the use of other component combinations (such as lamp / LED / Ballast / driver), or for use in different environmental conditions than that tested, may produce erroneous results. This report is free of erasures and corrections. Photometric intensity values are reported using the IESNA Type C coordinate system (L, V) as defined in IESNA publication LM-75. This report may contain data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government. -Jul-18 13:5:11 EPOT program version: 3.820a (issuing laboratory) Page of 12 13

Report of Test LLIA

Report of Test LLIA eport of Test LLIA001007-002 Catalog Number: F-AL/150/50K/S3 Total Light Output Luminaire Power Luminous Efficacy BUG ating 18778 lm 145.4 W 129.1 lm/w B3-U2-G3 Performance Summary Power Factor THD(i)

More information

Report of Test LLIA

Report of Test LLIA eport of Test LLIA000858-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 14313 lm 107.5 W 133.1 lm/w PEPAED FO : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742,

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 9457 lm 78.6 W 120.3 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000792-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 8616 lm 70.3 W 122.6 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL 34135,

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000795-002 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 35087 lm 296.1 W 118.5 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA55- Catalog Number: X One eldoled SOLOdriver 56/S, 5mA/May x25, LED driver 2.Vac, 6.Hz,.837A, 2.98W,.952PF, 5.44%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15551 Performance Summary Luminous flux Luminaire Power 2245 lm 27.7 W PREPARED FOR : Unilumin Group Co., Shenzhen, China, 518103. Page 1 of 12 Performance data in accordance with IESNA

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15538 Performance Summary Luminous flux Luminaire Power 11541 lm 145.4 W PREPARED FOR : Unilumin Group Co. Ltd., Shenzhen, China. 518103. Page 1 of 1 Performance data in accordance with

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL18297 Performance Summary Emergency Classification Luminous flux 89.6 lm Luminaire Power 1.05 W C0 D10 Luminous Efficacy 85.6 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL18299 Performance Summary Emergency Classification Luminous flux 87.6 lm Luminaire Power 1.14 W C0 D10 Luminous Efficacy 76.9 lm/w PREPARED FOR : Atom Lighting Ltd., Arundel, QLD 4214.

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000 Report No: L121706547 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706547 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400 Report No: L121706549 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706549 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05591-001B CPY250AxxFB-UL40Kxxxx / BXCCAxA13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320 Report No: L051602710 Date: 5/24/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051602710 HK Lighting Group

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim Report No: L121706467 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706467 Issue Date: 1/16/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI Report No: L061507804R01 Date: 3/27/2018 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507804R01 Report Prepared For: Beachside Lighting 905

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09300-001A ARE-EHO-3M-xx-12-E-UL-xx-1000-xxxx Date: 09/16/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot

More information

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI Report No: L061507814 Date: 7/24/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507814 Report Prepared For: Beachside Lighting 905 Kalanianaole

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71604 UPC Number 60198671604 Description LED Ultra Thin Canopy Fixture 45W Voltage: 120/208/240/277 QPL ID # P89A8PQ3 Features Intergral Cooling Fin Releases the Heat Efficiently to Maintain

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA. Report No: L051503301 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503301 Report Prepared For: SPJ Lighting 2107 Chino Ave.

More information

Cat# LED Linear High Bay 100W

Cat# LED Linear High Bay 100W Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0028 STR-LWY-4M-HT-06-E-UL-XX-700-40K-XXX or BXSL0406E-UD7 PL01059-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0025 STR-LWY-2M-HT-06-E-UL-XX-700-40K-XXX or BXSL0206E-UD7 PL01056-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: Product ID: CESTL-2013-0019 STR-LWY-5M-HT-06-E-UL-XX-700-40K-XXX or BXSL0506E-UD7 PL01041-001 Date: 2/05/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10710-001A OSQ-HO-A-xx-5SH-50L-50K-UL Date: 05/31/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Gerry Thornton

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09259-001A OSQ-HO-A-xx-15D-40L-40K-UL Date: 09/26/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree,

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION 2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063 Report No.: EED35I000235-1 Page 1 of 12 Customer : Revolution Lighting Technologies Address : 4139 Guardian Street, Simi Valley, CA93063 Description of the submitted sample(s): Sample Name : LED TUBE Model/Type

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 1 5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 8 foot mounting height. 7 3/4 1 3/4 3 1/8.02 0 3 1/2.01.005

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL11180-001A OSQ-HO-A-NM-3ME-65L-40K-UL-BZ Date: 08/10/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09255-002A OSQ-HO-A-xx-3ME-40L-40K-UL w/osq-ho-blsf Date: 09/09/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test LL15785 Performance Summary Luminous flux 540 lm Bare Lamp Power 7.76W SHR Nominal 0.75 SHR Maximum 0.79 PREPARED FOR : Indice Ecotech Pty. Ltd., Richmond, VIC 3121. Page 1 of 7 Performance

More information

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL IES LM-79-08 MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Test Model: IGTFL-1515050 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

PHONE: (303) FAX: (303) WEBSITE:

PHONE: (303) FAX: (303) WEBSITE: REPORT NUMBER: ITL71484 PAGE: 1 OF 7 CATALOG NUMBER: LFLED5 / LFLED5BR / LFLED5MBR (FLOOD SERIES) LUMINAIRE: CAST METAL HOUSING, CAST METAL CIRCUIT BOARD MOUNTING BASE, ONE CIRCUIT BOARD WITH ONE LED,

More information

LM-79 Report TEST REPORT NO.M037D

LM-79 Report TEST REPORT NO.M037D LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02141 PAGE: 1 OF 7 CATALOG NUMBER: PIP30/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB15W27-50K-D-T5-A-P

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02143 PAGE: 1 OF 7 CATALOG NUMBER: PIP15/D10 LUMINAIRE: ONE-PIECE CAST METAL HOUSING WITH PAINTED BRONZE FINISH, LED AND DRIVER COMPARTMENT SEPARATED BY FINNED HEAT SINK, ONE WHITE CIRCUIT

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: RESTL-2013-0012 E-HL6S11CSZ Date: 11/08/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Joshua Krohn Cree,

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

LM-79 Report TEST REPORT NO. L523A

LM-79 Report TEST REPORT NO. L523A LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For MaxLite Inc 10 York Ave West Caldwell NJ 07006 Test Laboratory: UL Verification Services (Guangzhou)

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/827K-DIM-G6 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0008 E-GL4S03C2K Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W