Verification Services Test Report
|
|
- Natalie Wright
- 5 years ago
- Views:
Transcription
1 Customer Company & Address ARTEMIDE S.P.A. Via Bergamo Pregnana Milanese (MI) Manufacturer: Artemide S.P.A. Country of Origin: Italy Country of Export: N/A Product Category: TOLOMEO LED TAVOLO Product Description: LED desk lamp Model Number(s): TOLOMEO LED TAVOLO Electrical Ratings: Vac 50-60Hz Test Sample(s) Received Date: 2012-NOV-06 Test Period: 2012-NOV-19 to 2012-NOV-19 The Sample(s) is(are) tested in accordance with the following: IES LM Prepared By Approved By Giovanni Di Martino Walter Parmiani Name & Signatory Name & Signatory This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. UL International Italia S.r.l. Via XXV Aprile 3/B Burago di Molgora (MB) Italy
2 Statement of Results Test Flow Test Method Sample ID Test Result 1. Goniophotometer S001 Evaluated by Customer 2. Integrating Sphere S001 Evaluated by Customer Measurement Uncertainty N/A Deviation from Test Method (if any) N/A Remarks (if any) N/A Notes (if any) This report extends to the 230Vac version of this product. This report extends to the following product also: TOLOMEO LETTURA LED, TOLOMEO MINI LED, TOLOMEO PINZA LED. Page 2 of 6
3 Test No. 1: Goniophotometer Sample ID / Test Round Number S001 / 1 Environmental Conditions 24 ºC Ambient Temperature Test Equipment Local ID Description Model BURVS0063 Goniophotometer system LSI 6440T BURVS0066 AC PSU ELGAR CW 1251 BURVS0065 Digital power meter Yokogawa WT210 S541 CHRONOMETER QUANTUM BURVS0067 THERMOMETER OMEGA MDSi8 Test Condition(s) Input Voltage Input Current Input Power Power Factor V 0.18 A W 0.50 Test Results Result Name Result Test Date 2012-NOV-19 11:00:00 AM Current THD 0.1 % Luminous Flux Luminous Efficacy Luminous Opening Length lm 33.4 lm/w 3.9 in. Luminous Opening Width 0.0 " Luminous Opening Height 0.0 " Page 3 of 6
4 Test No. 2: Integrating Sphere Sample ID / Test Round Number S001 / 1 Environmental Conditions 24.4 ºC Ambient Temperature Test Equipment Local ID Description Model BURVS0043 INTEGRATING SPHERE LABSPHERE 2m INTEGRATING SPHERE BURVS0048 SPECTRORADIOMETER LABSPHERE CDS-1100 BURVS0052 AC PSU CHROMA BURVS0049 DIGITAL POWER METER YOKOGAWA WT210 S541 DIGITAL CHRONOMETER QUANTUM BURVS0044 THERMOMETER OMEGA MDSi8 Test Condition(s) Base Orientation Input Voltage Input Current Input Power Power Factor Base Up 120 V 0.18 A W 0.50 Test Results Result Name Result Current THD 0.11 % CCT 2987 K CRI (Ra) Duv x y u' v' Page 4 of 6
5 Chromaticity diagram Spectral power distribution Page 5 of 6
6 Photo of Sample(s) Page 6 of 6
7 TEST REPORT No ARTEMIDE SPA,CAT# TOLOMEO TAVOLO LED LED. LUMINAIRE OUTPUT = 357 LMS. OPERATING AT 120VAC 60Hz W INTENSITY(CANDLEPOWER) SUMMARY ACROSS 45 ALONG ANGLE MEAN CP LUMENS ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LUMINAIRE EFFICACY (LUMENS PER WATT): 34.4 *** THIS IS AN ABSOLUTE TEST *** LUMINOUS DIAMETER: INS LUMINANCE SUMMARY - CD./SQ.M. ANGLE MEAN CD/SQ M CERTIFIED BY: DATE: NOV 29, PREPARED FOR: TESTED IN ACCORDANCE WITH IES PROCEDURES.
8 UL International Italia Srl Via XXV Aprile, 3/B Burago di Molgora, Italy TEST REPORT No ARTEMIDE SPA,CAT# TOLOMEO TAVOLO LED LED. LUMINAIRE OUTPUT = 357 LMS. OPERATING AT 120VAC 60Hz W INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE INTENSITY LUMENS (CANDLEPOWER)
9 UL International Italia Srl Via XXV Aprile, 3/B Burago di Molgora, Italy TEST REPORT No ARTEMIDE SPA,CAT# TOLOMEO TAVOLO LED LED. LUMINAIRE OUTPUT = 357 LMS. OPERATING AT 120VAC 60Hz W AVERAGE LUMINANCE DATA CD./SQ.M (FOOTLAMBERTS) ANGLE LUMINANCE ( 7850) ( 6975) ( 5970) ( 4902) ( 3562) ( 2420) ( 1492) ( 888) ( 494) ( 235) ( 136) ( 32)
10 UL International Italia Srl Via XXV Aprile, 3/B Burago di Molgora, Italy TEST REPORT No ARTEMIDE SPA,CAT# TOLOMEO TAVOLO LED LED. LUMINAIRE OUTPUT = 357 LMS. OPERATING AT 120VAC 60Hz W COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 CC WALL RCR THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 10.4 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
11 UL International Italia Srl Via XXV Aprile, 3/B Burago di Molgora, Italy TEST REPORT No CONE OF LIGHT MOUNTING HEIGHT ABOVE INITIAL FC 10% LIGHTED 50% LIGHTED WORK PLANE AT NADIR -FCN.1*FCN DIAMETER.5*FCN DIAMETER (FT) (FC) (FC) (FT) (FC) (FT) % CONE ANGLE: 96.7 DEGREES 50% CONE ANGLE: 60.2 DEGREES
CERTIFIED TEST REPORT No
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY ANGLE MEAN CP LUMENS
More informationLighting Sciences
Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT BEAM SIDE LUMENS
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL09633-001A LS4-50L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA 92808
Test #: S01130101 Date: 1/1/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationPage 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight
Page 2 of 14 Report No.: 68.184.15.296.01 Test sample... : Type of test object... : LED Downlight LED Downlight Trade mark... : Model and/or type reference... : EF150-26W-840 Rating(s)... : 220-240V~;
More informationLM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:
More informationReport No.: HZ p. (Lumens) Stabilization Time CRI (K)
Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL09234-001A ZR24M-50L-40K-10V-FD Date: 9/8/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationNVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:
More informationNVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )
LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationNVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.
LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation
More informationReport of Test LLIA A
Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,
More informationLM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084
LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09259-001A OSQ-HO-A-xx-15D-40L-40K-UL Date: 09/26/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree,
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L07121001 Date: 7/6/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L07121001 EDR-36NB-80-T5R-UNV-XXX-XX Report Prepared
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL11180-001A OSQ-HO-A-NM-3ME-65L-40K-UL-BZ Date: 08/10/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,
More informationReport of Test LLIA A
Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy
More informationNVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada
LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09255-002A OSQ-HO-A-xx-3ME-40L-40K-UL w/osq-ho-blsf Date: 09/09/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L06124406 Date: 7/11/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06124406 MLFP22E4535 Report Prepared For: MAXLITE
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL10710-001A OSQ-HO-A-xx-5SH-50L-50K-UL Date: 05/31/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Gerry Thornton
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy
More informationNVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503
Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationLightLab I N T E R N A T I O N A L
Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*
More informationReport of Test LLIA A
Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy
More informationCalibration Due Date Chroma Programmable AC Source 61604
Test #: L09123902 Date: 9/18/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L09123902 ECO5-JP-3-35F Report Prepared For: BARTCO
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationNVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)
LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608003 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608003 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationPhotometric Test Report. Keystone Technologies
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com
More informationPhotometric Test Report. Keystone Technologies
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com
More informationTest Report. Report Number: L16056 Date: Jun 14, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1656 Date: Jun 14, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 2 Test of one Vigilant H6 Series Unit manufacturer: Dialight Corporation Unit model number: H6xGMC9WN-xxxx
More informationTest Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1679 Date: Oct 12, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 2' Gen II Linear Unit manufacturer: Dialight Corporation Unit model number: LTx3B4B2W
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More informationTest Report. Report Number: L15097 Date: Jul 29, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1597 Date: Jul 9, 15 Issued by: 151 Route 34 South, Farmingdale, NJ 777 Test of one 14k C1D Vigilant High Bay Unit manufacturer: Dialight Corporation Unit model number: HEDGMC4GN-xxx
More informationMaxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.
Test #: L02144405 Date: 2/21/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L02144405 LSU2406U2050 / DV50 Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0008 E-GL4S03C2K Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.
Report No: L031603401 Date: 3/15/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L0031603401 Report Prepared For: Osram Sylvania, Inc. Model
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608103 Date: 4/28/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608103 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationTest Report. Report Number: L15098 Date: Jul 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L158 Date: Jul 28, 215 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 18k C1D2 Vigilant High Bay Unit manufacturer: Dialight Corporation Unit model number: HEDGMC4KN-xxx
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000
Report No: L121706547 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706547 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400
Report No: L121706549 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706549 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: RESTL-2013-0012 E-HL6S11CSZ Date: 11/08/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Joshua Krohn Cree,
More informationNVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)
LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska
More informationGM LIGHTING 9830 W 190th St, Torrance, CA 90503
Report No: L041609202 Date: 5/3/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609202 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: Product ID: CESTL-2013-0028 STR-LWY-4M-HT-06-E-UL-XX-700-40K-XXX or BXSL0406E-UD7 PL01059-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: Product ID: CESTL-2013-0025 STR-LWY-2M-HT-06-E-UL-XX-700-40K-XXX or BXSL0206E-UD7 PL01056-001 Date: 2/06/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing
More informationLightLab I N T E R N A T I O N A L
Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: Product ID: CESTL-2013-0019 STR-LWY-5M-HT-06-E-UL-XX-700-40K-XXX or BXSL0506E-UD7 PL01041-001 Date: 2/05/2012 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationPHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung
PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested LN130-A30 LED HIGH BAY Prepared for: Janie Chung KMW Inc. 183-6 Youngcheon-ro, Dongtan-myun Hwasung-si, Gyeonggi-do Korea 445-813 Phone: 253-826-7636
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W
More informationStandard-Tech Co. Ltd Testing Center
Test Datasheet Test Location: [ ] 1. B802, No.11 Caipin Road, Guangzhou Science City, Guangzhou, [ ] Guangdong, China 2. R108, 1 st Floor No.69 GuangPu West Road, Guangzhou Science City, Guangzhou, Guangdong,
More informationTest Report. Report Number: L16019 Date: Mar 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L1619 Date: Mar 21, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 2 Test of one CID1 Battery Backup Linear Unit manufacturer: Dialight Corporation Unit model number: LSC3C4MEGEX
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L091503801 Date: 9/16/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091503801 Report Prepared For: LEDCONN 301 Thor Place Model
More informationNVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)
LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher
More information