Characterization of acoustic properties of materials by means of the impulse response measurements. 1 Introduction

Size: px
Start display at page:

Download "Characterization of acoustic properties of materials by means of the impulse response measurements. 1 Introduction"

Transcription

1 Characterization of acoustic properties of materials by means of the impulse response measurements Simone Geroso, Alessandro Schiavi, Andrea Pavoni Belli, Francesco Russo, Mario Corallo Istituto Elettrotecnico Nazionale Galileo Ferraris, Torino, Strada delle Cacce 91, Italia, {geroso, schiavi, pavoni, russo, A linear and time-invariant system can be considered as a black-box, characterized by its impulse response h(t), that is the relationship between the output and the input signals of the system. The method of impulse response is based on this concept. In this paper are showed the results obtained applying the impulse response method for the determination of sound insulation of building elements and of sound absorption coefficient of objects and materials. The influence on the results of some parameters used in the determination of the impulse response has been analysed, in particular: number of measurement points, number of signal sequences, signal type, signal power. The measurements of sound insulation have been carried out in two ways: first with the traditional technique indicated in EN ISO 140-3, using two continuously moving microphones, and then with the impulse response method in some stationary microphone positions. Also the sound absorption coefficient measurements have been carried out in two ways: interrupted noise method and impulse response method in the same microphone positions. All results have been and some conclusions of interest are drawn concerning the respective uncertainties of measurements. 1 Introduction A linear and time-invariant system is considered like a black-box, characterized by its impulse response h(t). This impulse response is defined as the output of the same system when the input is the generalized Dirac delta function δ(t). This function is infinitely peaked at t=0 with the total area of unity. For this system the following equation is valid + () t x( t u) h( u) y = du (1) where y(t) is the output signal of the black-box and x(t) is the input signal. The relation (1) is the convolution of the input signal with the impulse response of the system. On the whole y(t), in a generic instant t, is obtained as linear combination of all past and future values of the input signal x(t). The impulse response h(t) behaves like weight-function of the linear combination. This interpretation of the input-output relation can intuitively justify the property of the system of being linear and time-invariant (LTI). In order to obtain the impulse response of an acoustic system, the Dirac delta signal δ(t) is not reproducible: therefore, by signal analysis theory, it is possible to use a particular signal like the MLS or the Sweep frequency. The application of the described signal analysis techniques to acoustic systems is increasing in these years. The introduction of Schroeder's backward integration has allowed to obtain the reverberation times from h(t). This has introduced measurements of impulse response of acoustic systems together with the traditional and always valid acoustic measurements: Standard ISO 354/2003, measurement of sound absorption in a reverberation room, introduces the impulse response method for measurements of reverberation time; Standard ISO 3382/97, measurement of the reverberation time of rooms with reference to other acoustical parameters, uses the impulse response measurement also for the calculation of acoustic parameters characterizing confined rooms. In this communication the results obtained applying the method of impulse response for the determination of the airborne sound insulation of buildings elements and the sound absorption coefficient of objects and materials are showed. Standard ISO 354/2003 admits the measurement of sound absorption coefficient in a reverberation room with the impulse response technique, considering the reverberation room system (with and without test material/object) and the relative microphone-source position as an LTI acoustic system. For the laboratory measurement of airborne sound insulation of building elements, Standard EN ISO 140-3/95 does not foresee the use of the impulse response method; however, it is possible to consider an LTI acoustic system constituted by two rooms separated by the test element, together with the relative position between the microphones (one in the source room and one in the receiving room) and the source. The influence on the results of some parameters used in impulse response determination has been analysed, such as: number of measurement points, number of signal sequences, signal type, signal power. The measurements of sound insulation have been made in 2245

2 two ways: first with the traditional technique indicated in EN ISO 140-3/95, using two continuously moving microphones, and then with the impulse response method in some stationary microphone positions. About the sound absorption coefficient, the values obtained with the interrupted noise method and those deducted from the impulse response method in the same microphone positions are compared. The results concern the respective measurements uncertainties. 2 Methodologies and instrumentation for sound absorption coefficient α/α w measurement The measurement of sound absorption coefficient have been executed in the reverberation room of the IEN Galileo Ferraris in compliance with the prescription and the conditions of test from Standard EN ISO 354/2003. With both methods of calculation of the reverberation time - interrupted noise (traditional) method and impulse response method -, four series of consecutive reverberation times have been made with and without the test specimen, each for four microphone positions. The traditional method is a reverberation time measurement through a multispectrum: the obtained 64 reverberation times, corresponding to the four microphone positions, are averaged. With impulse response method, the length of signal used (MLS or Sweep) is determined on the basis of the highest value of reverberation time. The values of reverberation time measured in the four microphone positions are averaged. The instrumentation is different for the two methodologies, except for the two omnidirectional sources Brüel & Kjær Type 4296 used together. For the traditional method we have used a condenser microphone ½ B&K type 4166 with preamplifier B&K type 2619, a four channels one-third-octave digital real time frequency analyzer Pulse B&K type 3560c, a digital equalizer Yamaha type DEQ 5 and a final power Amcron Crown type MICRO-TECH For the impulse response method we have used the program Dirac Room Acoustics Software B&K type 7841 installed on notebook with the audio card Vxpocket v2 Digigram, a microphone Neumann TLM170Rni, a one channel microphone power source G.R.A.S. Power Module type 12AK used as microphone amplifier signal and a power amplifier Crown D-75 A. 3 Methodologies and instrumentation for airborne sound insulation index R/R w measurement Airborne sound insulation index measurements were performed in the laboratory in compliance with Standard ISO 140-1/97: in particular, a source and a continuously moving microphone is placed in the source room while in the receiving room a second identical continuously moving microphone is placed for the space-temporal integration; the measurements is repeated for three different positions of the source. By means of an omnidirectional acoustic source it has been measured the reverberation time of the receiving room as the average on four microphone positions and two source positions; therefore all the elements necessary in order to calculate the defined airborne sound insulation index are stated. The instrumentation used for this measurement is: two condenser microphones ½ B&K type 4166 with preamplifier B&K type 2619, two rotary rod B&K type 3923, the analyzer is still Pulse B&K type 3560c therefore like the equalizer, the final power and the source. The measurements of airborne sound insulation index by means of the impulse response method have been executed using Dirac Room Acoustics Software B&K type 7841 [3]. This software is suitable for the measurement of room acoustic parameters, as specified in Standard ISO 3382/97. Among these parameters, the quantity G rel is defined as a relative sound pressure level i.e. the relationship between the measured sound pressure level in the enclosure and the input excitation signal power level, in logarithmic scale. This parameter measured in m microphone positions in the source room (G si ) and in n microphone positions in the receiving room (G ri ) allows to calculate the airborne sound insulation R, as a function of frequency, through the formula m GS, i n R = 10 log log 10 m i 1 n j= 1 S T + 10 log 0.16 GR, j 10 = V (2) where S is the area of test specimen, T the reverberation time and V the volume of the receiving room. The first term represents the average relative sound pressure level in the source room, the second term is the average relative sound pressure level in the receiving room and the last is a correction term due the reverberation time of receiving room. The instrumentation consists of two ½ B&K type 4166 microphones with preamplifier B&K type 2619, a dual microphone supply B&K type 5935 used also as amplifier microphone signal and power amplifier 2246

3 Crown D-75 A. The sources are the same as in the measurement described previously. 4 Results integrated impulse response method in accordance to EN ISO 354/2003). Description of the testing material is unimportant in this context because the objective is the comparison of the two different methods. For example, the graphs relative to the measurement of test specimen n 3 are shown in Figures 1 and Sound absorption coefficient α/α w Three measurements have been performed with two methods (typical interrupted noise method and Sound Absorption Coefficient with IR-MLS Sound Absorption Coefficient with IR-eSweep Sound Absorption Coefficient with Interrupted Noise [-] Figure 1: Sound absorption coefficient α of test specimen n [-] Uncertainties over the Sound Absorption Coeff. with IR-MLS Uncertainties over the Sound Absorption Coeff. with IReSweep Uncertainties over the Sound Absorption Coeff. with Interr. Noise Figure 2: Sound absorption coefficient α of test specimen n 3 and the uncertainties 2247

4 In Fig. 1 it can be noticed that the curves continuously intersect, in Fig. 2 the uncertainties on the measurement of sound absorption coefficient are shown. For the other test specimens the corresponding value of α w reported in table 1 shows an adequate agreement. Table 1: Weighted Sound absorption coefficient α w α w Test n.1 Test n.2 Test n.3 Imp. Resp. with MLS Imp. Resp. with lsweep Imp. Resp. with esweep Traditional Method R [db] R with IR- MLS R with IR- esweep R with Trad. Standard Method Figure 3: Airborne sound insulation R and the uncertainties Test specimen n Airborne sound insulation index R/R w measurement established in Standard ISO 140-2/91. For the other test specimens, the corresponding value of R w reported in table 2 shows an adequate agreement. Six measurement of airborne sound insulation have been performed. Description of the testing material is unimportant. The graphs obtained in the measurement of test specimen n 2 are shown in Fig. 3. The curves with the different types of signal used in impulse response method are within the uncertainty of 2248

5 Table 2: Weighted Airborne sound insulation R W (db) Test number Impulse Response Method Traditional Method In order to verify the compatibility between both measurement methods, it has been tried to reduce randomly the measurement points in the receiving and source rooms. The diagram in fig. 4 points out the curves of R obtained with different number of microphone positions: the observed variations among the curves are not significant. These variations are within the uncertainty of measurement. Also for R w index there are variations within ±1 db, as shown in Table [db] R 10 Mic. Points R 9 Mic. Points R 8 Mic. Points R 7 Mic. Points R 6 Mic. Points R 5 Mic. Points R 4 Mic. Points R 3 Mic. Points R 2 Mic. Points R 1 Mic. Points R Trad. Method Figure 4: Airborne sound insulation R reducing of the points of measurement and the uncertainties (test specimen n. 3) Table 3: Weighted Airborne sound insulation R W of test specimen n. 3, with measurements points reduced Number of measurements points R w IR Method / Trad. Method Trad. Method

6 5 Conclusions There is an adequate agreement between the measurements carried out with the traditional method and those carried out with the impulse response method, in order to evaluate the sound absorption coefficient and the airborne sound insulation. In the diagrams it is shown the validity of results within the uncertainty of the traditional measurement. Particularly, in sound absorption coefficient measurement the formula of the uncertainty has been extended also to the measurements performed by means of the impulse response method. As far as the airborne sound insulation it has been possible to verify that with impulse response method few microphone points of measurements are required, it means a fastest measurement than the traditional measurement with continuously moving microphone. This is also an interesting application in the measurement in situ. Finally both the verification of measurements compatibility and measurement uncertainties calculation must be extended and investigated, specially for the measurements of airborne sound insulation by means of the impulse response method. References [1] ISO/FDIS 354:2003 Acoustics -- Measurement of sound absorption in a reverberation room [2] ISO 3382:1997 Acoustics -- Measurement of the reverberation time of rooms with reference to other acoustical parameters [3] Acoustics Engineering, Technical Notes Insulation Measurements using Dirac, August 2003, [4] EN ISO 140-3:1995 Acoustics -- Measurement of sound insulation in buildings and of building elements -- Part 3: Laboratory measurements of airborne sound insulation of building elements [5] ISO 140-2:1991 Acoustics -- Measurement of sound insulation in buildings and of building elements -- Part 2: Determination, verification and application of precision data [6] M. Schroeder, New method of measuring reverberation time. J. Acoust. Soc. Am., Vol. 37. pp (1965) 2250

Modern measurement techniques in room and building acoustics

Modern measurement techniques in room and building acoustics Das Messen in der Raum- und Bauakustik Michael Vorländer Institut für Technische Akustik RWTH Aachen Modern measurement techniques in room and building acoustics Introduction Modern versus classical methods

More information

Measurement of Acoustic Properties of light weight concrete SL-Deck

Measurement of Acoustic Properties of light weight concrete SL-Deck DELTA Test Report TEST Reg. no. 100 Measurement of Acoustic Properties of light weight concrete SL-Deck Performed for Abeo A/S Project no.: I100486 Page 1 of 25 30 June 2014 DELTA Venlighedsvej 4 2970

More information

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES P-7 THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES RYU, YUNSEON BRUEL & KJAER SOUND & VIBRATION MEASUREMENT A/S SKODSBORGVEJ 307 NAERUM 2850 DENMARK TEL : +45 77 41 23 87 FAX : +45 77

More information

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics DELTA Test Report TEST Reg. no. 100 Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object Performed for Flex Acoustics Project no.: T202611 Page 1 of 7 21 January 2013 DELTA Venlighedsvej

More information

REPORT N CR

REPORT N CR Z Lab Srl Via Pisa, 5/7 37053 Cerea (VR) Italy Tel. +39 0442 410280 Fax +39 0442 418090 info@zeta-lab.it www.zeta-lab.it C.F./P.IVA 02984950788 Cap. Soc. 80.000 i.v. R.E.A. c/o C.C.I.A.A. Verona 376649

More information

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 100 Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time Client: Kvadrat Soft Cells A/S Page 1

More information

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2 LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C423-01 Type E Mounting Date of Test: 27/11/2009 Report Author: Mark Simms Test Number 2 Report Number 1644 Report Number 1644 Page

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.2 LABORATORY MEASUREMENT

More information

Cepstral Deconvolution Method for Measurement of Absorption and Scattering Coefficients of Materials

Cepstral Deconvolution Method for Measurement of Absorption and Scattering Coefficients of Materials Cepstral Deconvolution Method for Measurement of Absorption and Scattering Coefficients of Materials Mehmet ÇALIŞKAN a) Middle East Technical University, Department of Mechanical Engineering, Ankara, 06800,

More information

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room INTERNATIONAL STANDARD ISO 354 Second edition 2003-05-15 Acoustics Measurement of sound absorption in a reverberation room Acoustique Mesurage de l'absorption acoustique en salle réverbérante Reference

More information

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room Proceedings of ACOUSTICS 6 20-22 November 6, Christchurch, New Zealand Some issues in measurement of the random-incidence scattering coefficients in a reverberation room Young-Ji Choi, Dae-Up Jeong and

More information

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07 Test Report RI Acoustic Lab Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier 20 Feb. 07 Title Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier

More information

Measurement of sound absorption coefficient for Fraster felt SpaceCover

Measurement of sound absorption coefficient for Fraster felt SpaceCover DELTA Test Report TEST Reg. no. 100 Measurement of sound absorption coefficient for Fraster felt SpaceCover Performed for Fraster ApS Project no.: I100645 Page 1 of 9 27 November 2014 DELTA Venlighedsvej

More information

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Available online at   ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015 Available online at www.sciencedirect.com ScienceDirect Energy Procedia 78 (2015 ) 128 133 6th International Building Physics Conference, IBPC 2015 Sound insulation of building elements at low frequency:

More information

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm DELTA Test Report TEST Reg. no. 100 Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm Performed for Fraster ApS DANAK 100/2275 Project no.:

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 462257-01 Sound Absorption Impact Sound Insulation Customer Desso B.V. Taxandriaweg 15 5142 PA Waalwijk NETHERLANDS Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS Report No. L/3237 Page 1 of 8 for Oscar Acoustics Michaels Lane Ash Kent TN15 7HT Dated: 24 July 2012 LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS Report Author: M Sawyer

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 140-6 Second edition 1998-08-15 Acoustics Measurement of sound insulation in buildings and of building elements Part 6: Laboratory measurements of impact sound insulation of

More information

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM. REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM. Testing Procedure: AS ISO 354-2006 Testing Laboratory: Client:

More information

Measuring HRTFs of Brüel & Kjær Type 4128-C, G.R.A.S. KEMAR Type 45BM, and Head Acoustics HMS II.3 Head and Torso Simulators

Measuring HRTFs of Brüel & Kjær Type 4128-C, G.R.A.S. KEMAR Type 45BM, and Head Acoustics HMS II.3 Head and Torso Simulators Downloaded from orbit.dtu.dk on: Jan 11, 219 Measuring HRTFs of Brüel & Kjær Type 4128-C, G.R.A.S. KEMAR Type 4BM, and Head Acoustics HMS II.3 Head and Torso Simulators Snaidero, Thomas; Jacobsen, Finn;

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 471194-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 481380-01 Sound Absorption Impact Sound Insulation Customer NEWSPEC CARPET (NINGBO) CO. LTD Cevin Yindong South Road NO. 399 315100 Ningbo CHINA VR Product textile floor covering This report

More information

Modified wave equation for modelling diffuse sound field

Modified wave equation for modelling diffuse sound field Challenges and Solutions in Acoustic Measurements and Design: Paper ICA2016-337 Modified wave equation for modelling diffuse sound field Hugo Dujourdy (a,b), Baptiste Pialot (b), Thomas Toulemonde (a),

More information

MAC Aura XB Acoustic Test Report

MAC Aura XB Acoustic Test Report MAC Aura XB Acoustic Test Report 2017. Information subject to change without notice. HARMAN Professional and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss,

More information

ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS

ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS Franco Cotana 1, Federico Rossi 2, Andrea Nicolini 1 and Sofia Simoni 2 1 University of Perugia Industrial Engineering Department Via G.

More information

Using an ambisonic microphone for measurement of the diffuse state in a reverberant room

Using an ambisonic microphone for measurement of the diffuse state in a reverberant room Proceedings of 20 th International Congress on Acoustics, ICA 2010 23-27 August 2010, Sydney, Australia Using an ambisonic microphone for measurement of the diffuse state in a reverberant room John Bassett

More information

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS Prepared for: MONOGLASS INC. 922-1200 West 73rd Avenue Vancouver, BC, Canada V6P 6G5 Prepared by: THE

More information

Laser scanning vibrometry measurements on a light weight building element

Laser scanning vibrometry measurements on a light weight building element Laser scanning vibrometry measurements on a light weight building element N.B. Roozen, M. Rychtáriková, Katholieke Universiteit Leuven, Laboratory for Acoustics and Thermal Physics (ATF), Department of

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2803547 Supplied

More information

Consultancy Report Ref: 9383-R01

Consultancy Report Ref: 9383-R01 Consultancy Report Ref: 9383-R01 Submitted to: Prepared by: Mr Tim Simmons The Woolley Shepherd Secret Meadow Weekmoor Milverton Taunton TA4 1QE John Fithyan Laboratory Manager Approved for issue by: Andy

More information

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels. Technical Report Ref Number C/21387/R01a Date 06 April 2011 Project The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels Prepared for Rockfon Rockwool A/S

More information

Development of a small-scale reverberation room

Development of a small-scale reverberation room Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Development of a small-scale reverberation room Alexander Rasa Noise Control Research & Development, Pyrotek Pty Ltd, Sydney, Australia

More information

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient Hyojin LEE, Tetsuya SAKUMA Graduate School of Frontier Sciences, University of Tokyo, Kashiwa, Japan. 1. Introduction

More information

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices) issued by an Accredited Testing Laboratory Date Reference Page 2011-05-16 PX03759-02-5A 1 (3) Contact person Xuetao Zhang Energy Technology +46 10 516 50 21, xuetao.zhang@sp.se SP Wood Technology Att:

More information

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM. RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON

More information

Testing Procedure: AS ISO

Testing Procedure: AS ISO RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON

More information

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION 000059.doc/0 EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION M. GARAI, P. GUIDORZI DIENCA, University of Bologna, Viale Risorgimento 2, 40136,

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 480781-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

Evaluation of standards for transmission loss tests

Evaluation of standards for transmission loss tests Evaluation of standards for transmission loss tests M. Cassidy, R. K Cooper, R. Gault and J. Wang Queen s University Belfast, School of Mechanical and Aerospace Engineering, Ashby Building, Stranmillis

More information

EURAMET Project 1056

EURAMET Project 1056 EURAMET Project 56 Inter-laboratory comparison on measurement of free-field response of a sound level meter. Final Report January 2 Claudio Guglielmone INRiM Divisione Termodinamica 2. Introduction EURAMET

More information

Yalıtım Kontrol Koruma. Insulation Control Protection

Yalıtım Kontrol Koruma. Insulation Control Protection Yalıtım Kontrol Koruma Insulation Control Protection Tunex 17/8 ISO 10140-3 Darbe Sesi İndirgeme (Impact Sound Insulation) Test Raporu page 1 of 15 Customer : DKM INSAAT TAAHHUT VE DANISMANLIK PAZARLAMA

More information

Module 1: Signals & System

Module 1: Signals & System Module 1: Signals & System Lecture 6: Basic Signals in Detail Basic Signals in detail We now introduce formally some of the basic signals namely 1) The Unit Impulse function. 2) The Unit Step function

More information

Microphone and Sound Level Meter calibration in free field by a new method

Microphone and Sound Level Meter calibration in free field by a new method XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil Microphone and Sound Level Meter calibration in free field by a new method Zemar M. Defilippo

More information

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software Overview Measuring Systems AcoustiFlow Airflow resistivity meter AcoustiAdrienne

More information

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant: TEST REPORT This Test Report may only be reproduced in full. The test results are valid for the tested object only. Fibertex Nonwovens A/S Laboratory measurements of sound absorption coefficient Page 1

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10848-3 First edition 2006-04-01 Acoustics Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms Part 3: Application to light

More information

Therefore the new Fourier coefficients are. Module 2 : Signals in Frequency Domain Problem Set 2. Problem 1

Therefore the new Fourier coefficients are. Module 2 : Signals in Frequency Domain Problem Set 2. Problem 1 Module 2 : Signals in Frequency Domain Problem Set 2 Problem 1 Let be a periodic signal with fundamental period T and Fourier series coefficients. Derive the Fourier series coefficients of each of the

More information

Modeling Measurement Uncertainty in Room Acoustics P. Dietrich

Modeling Measurement Uncertainty in Room Acoustics P. Dietrich Modeling Measurement Uncertainty in Room Acoustics P. Dietrich This paper investigates a way of determining and modeling uncertainty contributions in measurements of room acoustic parameters, which are

More information

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING Report No. L/3194 Page 1 of 8 for EA Mimarlik Insaat Teknolojileri San.ve. Tic.Ltd.Sti 1420/3 Sokak NO. 22 Kizilkanat Silesi D Blok D.12 Alsancak Izmir Turkey Dated: 18 July 2011 LABORATORY MEASUREMENTS

More information

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES FOR: Indianapolis, IN. Sound Absorption CONDUCTED: 2015-10-06 Page 1 of 7 ON: LENRD Bass Trap TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute

More information

ACOUSTIC INTRINSIC PERFORMANCES OF NOISE BARRIERS: ACCURACY OF IN SITU MEASUREMENT TECHNIQUES

ACOUSTIC INTRINSIC PERFORMANCES OF NOISE BARRIERS: ACCURACY OF IN SITU MEASUREMENT TECHNIQUES Twelfth International Congress on Sound and Vibration ACOUSTIC INTRINSIC PERFORMANCES OF NOISE BARRIERS: ACCURACY OF IN SITU MEASUREMENT TECHNIQUES Francesco Asdrubali, Giulio Pispola and Francesco D Alessandro

More information

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied

More information

ENSC327 Communications Systems 2: Fourier Representations. Jie Liang School of Engineering Science Simon Fraser University

ENSC327 Communications Systems 2: Fourier Representations. Jie Liang School of Engineering Science Simon Fraser University ENSC327 Communications Systems 2: Fourier Representations Jie Liang School of Engineering Science Simon Fraser University 1 Outline Chap 2.1 2.5: Signal Classifications Fourier Transform Dirac Delta Function

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission INTERNATIONAL STANDARD ISO 230-5 First edition 2000-08-01 Test code for machine tools Part 5: Determination of the noise emission Code d'essai des machines-outils Partie 5: Détermination de l'émission

More information

Renolit stretch ceilings

Renolit stretch ceilings Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Convolution. Define a mathematical operation on discrete-time signals called convolution, represented by *. Given two discrete-time signals x 1, x 2,

Convolution. Define a mathematical operation on discrete-time signals called convolution, represented by *. Given two discrete-time signals x 1, x 2, Filters Filters So far: Sound signals, connection to Fourier Series, Introduction to Fourier Series and Transforms, Introduction to the FFT Today Filters Filters: Keep part of the signal we are interested

More information

INFLUENCE OF TIME-VARIANCE IN AUDITORIUM ON IMPULSE RESPONSE MEASUREMENT

INFLUENCE OF TIME-VARIANCE IN AUDITORIUM ON IMPULSE RESPONSE MEASUREMENT INFLUENCE OF TIME-VARIANCE IN AUDITORIUM ON IMPULSE RESPONSE MEASUREMENT PACS: 43.55.MC Satoh Fumiaki* 1 ; Nagayama Mitsuru* 1 ; Tachibana Hideki* 2 *1 Chiba Institution of Technology Tsudanuma 2-17-1,

More information

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT SCOPE OF WORK ASTM C423 SOUND ABSORPTION TESTING ON TEMPE, ROLLER SHADE FABRIC REPORT NUMBER I7375.01-113-11-R0 TEST DATE 08/14/18 ISSUE DATE 09/04/18

More information

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Germany Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE A.B.N. 73 107 291 494 C O N S U L T I N G A C O U S T I C A L E N G I N E E R S MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE 100 mm ANCIENT STONE BRICK REPORT NUMBER: 4546-2 PREPARED FOR: Timbercrete Pty

More information

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M.Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES FOR: Atlanta, GA Sound Absorption CONDUCTED: 2016-10-14 Page 1 of 8 ON: D-GIK Panels TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute of

More information

Study of Wenger Audience Seating Chair Absorption. Ron Freiheit

Study of Wenger Audience Seating Chair Absorption. Ron Freiheit Study of Wenger Audience Seating Chair Absorption Ron Freiheit January 22, 2002 Study of Wenger Audience Seating Chair Absorption Purpose The purpose of this project was to evaluate the acoustical performance

More information

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia) SIA * R & D AKUSTIKA * ============================================================================================= LATVIJAS REPUBLIKA, LV - 1067, R GA, KURZEMES PROSPEKTS 3, Re istr. Nr. : LV 010310045

More information

Qualitative behaviour of L1 and L2 standard deviation in insulations measurements according to standard UNE EN ISO 140-4

Qualitative behaviour of L1 and L2 standard deviation in insulations measurements according to standard UNE EN ISO 140-4 Qualitative behaviour of L and L standard deviation in insulations measurements according to standard UNE EN ISO 4-4 María A. Navacerrada, Cesar Díaz and Antonio Pedrero Grupo de Acústica Arquitectónica,

More information

Analysis and synthesis of room reverberation based on a statistical time-frequency model

Analysis and synthesis of room reverberation based on a statistical time-frequency model Analysis and synthesis of room reverberation based on a statistical time-frequency model Jean-Marc Jot, Laurent Cerveau, Olivier Warusfel IRCAM. 1 place Igor-Stravinsky. F-75004 Paris, France. Tel: (+33)

More information

Test Signal Selection for Determining the Sound Scattering Coefficient in a Reverberation Chamber

Test Signal Selection for Determining the Sound Scattering Coefficient in a Reverberation Chamber ARCHIVES OF ACOUSTICS Vol.37,No.4, pp.405 409(2012) Copyright c 2012byPAN IPPT DOI: 10.2478/v10168-012-0051-2 Test Signal Selection for Determining the Sound Scattering Coefficient in a Reverberation Chamber

More information

UNCERTAINTY OF FAÇADE SOUND INSULATION MEAS- UREMENTS OBTAINED BY A ROUND ROBIN TEST: THE IN- FLUENCE OF THE LOW FREQUENCIES EXTENSION

UNCERTAINTY OF FAÇADE SOUND INSULATION MEAS- UREMENTS OBTAINED BY A ROUND ROBIN TEST: THE IN- FLUENCE OF THE LOW FREQUENCIES EXTENSION UNCERTAINTY OF FAÇADE SOUND INSULATION MEAS- UREMENTS OBTAINED BY A ROUND ROBIN TEST: THE IN- FLUENCE OF THE LOW FREQUENCIES EXTENSION Chiara Scrosati and Fabio Scamoni ITC-CNR Construction Technologies

More information

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE Wan-Ho Cho, Hyu-Sang Kwon, and Ji-Ho Chang Korea Research Institute of Standards and Science, Center

More information

A new Audacity feature: room objective acustical parameters calculation module

A new Audacity feature: room objective acustical parameters calculation module A new Audacity feature: room objective acustical parameters calculation module Simone CAMPANINI and Angelo FARINA Departement of Industrial Engineering - University of Parma viale G.P.Usberti, 181/A 431

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Architectural Acoustics Session 1pAAa: Advanced Analysis of Room Acoustics:

More information

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric REFLECTACOUSTIC

Fabric REFLECTACOUSTIC Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements ODEON APPLICATION NOTE Calibration of Impulse Response Measurements Part 2 Free Field Method GK, CLC - May 2015 Scope In this application note we explain how to use the Free-field calibration tool in ODEON

More information

A L I O N Technical Center. Test Report

A L I O N Technical Center. Test Report FOR: Beachwood, OH Sound Absorption CONDUCTED: 2017-10-30 Page 1 of 7 ON: Absorption Sheets TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute

More information

On the declaration of the measurement uncertainty of airborne sound insulation of noise barriers

On the declaration of the measurement uncertainty of airborne sound insulation of noise barriers On the declaration of the measurement uncertainty of airborne sound insulation of noise barriers Massimo Garai and Paolo Guidorzi 2,2 University of Bologna - DIN Viale Risorgimento 2, 036 Bologna, Italy

More information

The effect of an edge on the measured scattering coefficients in a reverberation chamber based on ISO

The effect of an edge on the measured scattering coefficients in a reverberation chamber based on ISO Proceedings of the International Symposium on Room Acoustics, ISRA 2010 29-31 August 2010, Melbourne, Australia The effect of an edge on the measured scattering coefficients in a reverberation chamber

More information

Acoustic response in non-diffuse rooms

Acoustic response in non-diffuse rooms Acoustic response in non-diffuse rooms Jack Harvie-Clark Apex Acoustics, Gateshead, United Kingdom. Nicholas Dobinson Apex Acoustics, Gateshead, United Kingdom. Richard Hinton Apex Acoustics, Gateshead,

More information

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 9, 23 http://acousticalsociety.org/ ICA 23 Montreal Montreal, Canada 2-7 June 23 Architectural Acoustics Session aaaa: Advanced Analysis of Room Acoustics: Looking

More information

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement ECMA-275-1 4 th Edition / December 2017 Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement Reference number ECMA-123:2009

More information

SIS project n 1: Sound detection with a real e-puck. David FitzGerald Daniel Kroiss

SIS project n 1: Sound detection with a real e-puck. David FitzGerald Daniel Kroiss SIS project n 1: Goal: Program an e-puck in order to find a sound source. Equipment: Two e-pucks Three batteries Bluetooth USB key Programming language: C 2 Procedure: 1. Record the sound 2. Apply the

More information

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements. Edinburgh, Scotland EURONOISE 00 October - An examination of some aspects of the use of ISO 0 Part and in field measurements. Philip R Dunbavin a Philip Dunbavin Acoustics Ltd (ANC) Keepers House, Deans

More information

In situ measurement methods for characterising sound diffusion

In situ measurement methods for characterising sound diffusion Proceedings of the International Symposium on Room Acoustics, ISRA 9 August, Melbourne, Australia In situ measurement methods for characterising sound diffusion I. Schmich (), N. Brousse () () Université

More information

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Phys. Elmar Schröder Telephone +49(89)85602 145 Elmar.Schroeder@mbbm.com

More information

Curtain fabric type Ace Manufacturer Kvadrat A/S

Curtain fabric type Ace Manufacturer Kvadrat A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

2.161 Signal Processing: Continuous and Discrete Fall 2008

2.161 Signal Processing: Continuous and Discrete Fall 2008 MIT OpenCourseWare http://ocw.mit.edu 2.161 Signal Processing: Continuous and Discrete Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms. Massachusetts

More information

Frequency Response and Continuous-time Fourier Series

Frequency Response and Continuous-time Fourier Series Frequency Response and Continuous-time Fourier Series Recall course objectives Main Course Objective: Fundamentals of systems/signals interaction (we d like to understand how systems transform or affect

More information

SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS. Jukka Keränen, Petra Larm, Valtteri Hongisto

SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS. Jukka Keränen, Petra Larm, Valtteri Hongisto SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS Jukka Keränen, Petra Larm, Valtteri Hongisto Finnish Institute of Occupational Health Laboratory of Ventilation and Acoustics

More information

The practical application of G and C 50 in classrooms

The practical application of G and C 50 in classrooms The practical application of G and C 50 in classrooms Jack Harvie-Clark 1, Nicholas Dobinson 2 1 Apex Acoustics Ltd 2 Apex Acoustics Ltd ABSTRACT Reverberation time remains the primary indicator of room

More information

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric TWIST MELANGE Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Influence of directivity and spectral shape on the measured sound power level

Influence of directivity and spectral shape on the measured sound power level Influence of directivity and spectral shape on the measured sound power level K. Voelkel 1, V. Wittstock Physikalisch Technische Bundesanstalt, Braunschweig, Germany ABSTRACT The sound power is the main

More information

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada FOR: Port Coquitlam, British Columbia, Canada Sound Absorption CONDUCTED: 2018-03-19 Page 1 of 7 ON: Model F202-2448 - Hercules absorption panels TEST METHOD Riverbank Acoustical Laboratories is accredited

More information

Fabric Medley Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Signals & Systems interaction in the Time Domain. (Systems will be LTI from now on unless otherwise stated)

Signals & Systems interaction in the Time Domain. (Systems will be LTI from now on unless otherwise stated) Signals & Systems interaction in the Time Domain (Systems will be LTI from now on unless otherwise stated) Course Objectives Specific Course Topics: -Basic test signals and their properties -Basic system

More information

ISSUES ON THE REVERBERATION ROOM METHOD FOR MEASURING THE SCATTERING COEFFICIENTS -BORTHER SETTING AND REVOLUTION OF TEST SAMPLE-

ISSUES ON THE REVERBERATION ROOM METHOD FOR MEASURING THE SCATTERING COEFFICIENTS -BORTHER SETTING AND REVOLUTION OF TEST SAMPLE- ISSUES ON THE REVERBERATION ROOM METHOD FOR MEASURING THE SCATTERING COEFFICIENTS -BORTHER SETTING AND REVOLUTION OF TEST SAMPLE- Hyojin LEE 1 ; Yuzo TSUCHIYA 2 ; Tetsuya SAKUMA 3 1,2,3 Graduate School

More information

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information