Accurate Mass for GC/MSD & LC/MSD
|
|
- Milton Cole
- 5 years ago
- Views:
Transcription
1 Accurate Mass for GC/MSD & LC/MSD A Presentation at Agilent Hospitality VIP Event Yongdong Wang, PhD Cerno Bioscience Norwalk, CT, USA June 6, 2018
2 Agenda Cerno s Novel MS Calibration: Why & How Application to GC/MSD Application to LC/MSD
3 Cerno/Agilent Startup in Norwalk, CT, USA MS calibration & analysis technology 14 granted/pending patents world-wide MassWorks software product: Standalone post acquisition application software V1.0, PittCon Bronze Medal (now V5.0) Supports nearly all MS systems but works the best on Agilent MSD Over 1,200 customers in US, Canada, Europe, Japan, China etc Agilent partnership Key function: the only approach for accurate mass formula determination / compound ID with a quadrupole MS Real key technical advance: Spectral Accuracy
4 Rel. Abundance Actual MS (Profile/Raw): C 25 H 23 N 2 OS Quadrupole, R = m/z
5 Rel. Abundance After MS Centroiding: C 25 H 23 N 2 OS Quadrupole, R = m/z
6 Rel. Abundance True Mass Spectrum: C 25 H 23 N 2 OS True Mass R = Infinity m/z
7 Rel. Abundance Enough Details Even at Low Res Mass R= C 33 S 15 N 2 H C25H23N2OS C4H19N16OF2NaP C20H27N2FNaP2 C9H33N6O3S2P2 C10H27N10OS m/z
8 True Raw True m/z-only & Profile Fully Mass MS Mass Calibrated Calibration Spectrum and True MS MS Mass Accuracy Plus Spectral Accuracy m/z 8
9 counts Mass Accuracy Average of all RT Windows - C:\TestData\T42Desktop\BobStrife\MS-MS\101306_1.raw\_FUNC001.crn Raw: mass accuracy ±0.2~0.5Da Calibrated: mass accuracy ±0.002~0.005Da x better mass accuracy m/z
10 ±5mDa/400Da = ±12ppm?!
11 ±5ppm Tough Even for TOF Row Formula Mono Isotope Mass Error (mda) Mass Error (ppm) Spectral Accuracy RMSE DBE 1 C19H15N10O E C19H23N6S E C6H23N8O E C11H19N12O3S E C14H27N2O9S E C11H27N8O2S E C26H23O2S E C22H23O E C18H19N6O E C15H31N2O4S E C18H27N2O4S E C7H19N12O E C10H23N8O7S E C15H23N6O5S E C23H27O2S E C23H19N4O E C17H23N2O E C8H23N12O3S E C16H27N6S E C8H15N16O E C17H27N4O3S E
12 Enters Spectral Accuracy
13 counts Spectral Accuracy Average of Scans 14 thru 49 (0.25 to 0.87) Calibrated MS Theoretical MS Unparalleled Spectral Accuracy m/z
14 Technology: Patented, Peer-Reviewed & Published Wang, Y.; Gu, M. Anal. Chem. 2010, 82, (17).
15 Agilent/Cerno Partnership MassWorks for GC/MSD, Agilent Part # G6851AA MassWorks for LC/MSD, Agilent Part # G6887AA Specially configured version with highly attractive pricing when bundled with new MSD purchase Unique ease of use: GC/MSD-only AutoCal Unique spec among all SQ systems: Mass accuracy: ±0.005 Da Spectral accuracy: 99%
16 GC/MSD: Hardware Advantages Heated gold-coated ceramic quads Superb stability and reproducibility /how to quantify? High mass accuracy demonstratable w/ RIGHT calibration Raw Scan (Profile) mode readily available! None of detrimental on-board processing/filtering Compromised spectral accuracy Wide (5-6 orders of) linear dynamic range High spectral accuracy
17 counts relative abundance PFTBA Valve On PFTBA Valve Off GC/MS: Readily Available Cal Gas E:\Mulligan\ \TETSR3.D\DATA.MS GC Peak of Unknown Average of Scans 1398 thru 1439 (12.23 to 12.47) minutes CF C 9 F 20 N m/z Available on all GC/MS systems Computer-controllable & user-programmable Fragment ions covering Da Even internal to a GC/MS run
18 AutoCal : Out-of-Box Accurate Mass Mass accurate to 0.00x Da
19 Unique Specifications for 5977 EI SIM IDL (Helium Carrier gas with Auto Liquid Sampler) 10 fg or less IDL for Extractor ion source, turbo molecular pump system 24 fg or less for Inert EI source, turbo molecular pump system 30 fg or less for Inert EI source, diffusion pump system IDL statistically derived at 99% confidence level from the area precision of eight sequential splitless injections of 100 fg OFN,monitoring m/z 272. EI scan S/N (Helium carrier gas manual injection) 1500:1 or higher S/N for Extractor ion source, turbo molecular pump system 600:1 or higher for Inert EI Ion Source, turbo molecular pump system 300:1 or higher for Inert EI Ion Source, diffusion pump system These numbers will be given by 1-μL injection of 1 pg/μl OFN standard scanning from 50 to 300 u at nominal u ion. PCI scan S/N (Methane) 125:1 S/N will be given by 1-μL injection of 100-pg/μL BZP2 standard scanning from 80 to 230 u at nominal 183 u ion NCI scan S/N (Methane) 600:1 S/N will be given by 2-μL injection of 100 fg/μl OFN standard scanning from 50 to 300 u at nominal 272 u ion Mass Accuracy Spectral Accuracy 1-uL injection of a 100-pg/uL OFN standard scanning from u will give its monoisotope at m/z ± uL injection of a 100-pg/uL OFN standard scanning from u will give 99.0% spectral accuracy
20 Unique Specifications for LC/MSD EN: EN: InfinityLab LC/MSD Series Agilent LC/MSD XT For For OpenLAB CDS CDS and and OpenLAB CDS CDS ChemStation Edition
21 Applications Elemental composition determination (research/education/teaching) Forensics chemistry Pharma impurity ID Spectral accuracy for mixture analysis M+ and (M-H)+ in EI Labeled isotopes LC or MS peak purity: deamidation of biologics Metal organics, catalyst etc
22 Elemental Composition Determination Rank Formula Spectral Accuracy (%) C9H2N2O6F2 C2HN2O3F9 C10N2O3F4 C7HN4O7F C15N2O4 C10N4O6 C4N8O7 C20O2 C10F
23 counts relative abundance PFTBA Valve On PFTBA Valve Off Forensics Chemistry Unknown E:\Mulligan\ \TETSR3.D\DATA.MS GC Peak of Unknown Average of Scans 1398 thru 1439 (12.23 to 12.47) minutes CF C 9 F 20 N m/z
24 c ount s c ount s GC/MS Calibration A v er age of S c ans 785 t hr u 799 ( t o 8. 74) A v er age of S c ans 785 t hr u 799 ( t o 8. 74) m / z m / z MassWorks calibrates {m/z, peak shape} to improve mass accuracy by up to 100x
25 GC/MS Formula ID Correct identification w/ Spectral Accuracy
26 NIST Library Search w/same Data Acquisition
27 A Highly Toxic Compound Not Found in NIST Library
28 A Highly Toxic Compound Not Found in NIST Library
29 LC/MSD MassWorks Calibration Agilent tune solution: Universal standard (wide m/z range, ESI+ and ESI-) Stable and readily available External acquisition preferred Calibration drift: not significant (~5mDa/day) Known internal standards in sample, e.g., API Conveniently found within same sample Internal within same run No extra experimental work/acquisition Limited m/z range coverage: effective ±100Da
30 Agilent Tune Solution Calibration 10uL loop injection
31 Drug Impurity ID: Parent Drug as Calibration Standards Parent Impurity #1 Impurity #2 RT Window Name Formula Entry Net Formula Charge Mono Isotope Centroid Left Edge Right Edge 1 0: Scans Simvastatin C25H39O5 C25H39O : Scans NH4 Adduct C25H42NO5 C25H42NO : Scans K Adduct C25H38O5K C25H38O5K All
32 Drug Impurity ID #1
33 Drug Impurity ID #2 Impurity in impurity
34 [C14] Ring Labeled Compounds: Diclofenac Experimental * Diclofenac Sodium C14H10Cl2NNaO2 [14C] labeled SA=62.7 mci/mmol 7 possible isotopes Native, 1[14C] - 6[14C]
35 Results of Spectral Accuracy Mixture Analysis
36 GC/MSD RCM Paper: Flavor
37 GC/MSD RCM Paper: Forensics
38 LC/MS Paper: HDX Kinetics
39 LC/MS: Environmenal
40 Application Areas Pharmaceutical impurity ID: must have Small molecule or large biologics Leachables / Extractables Food / Beverages / Beer / Wine / Liquor Flavor / Fragrances / Cosmetics / Natural products Academic / Government Labs: Organic synthesis or other research support/acs journal accepted Novel tool to teach MS and accurate mass concept Forensics / Crime labs / Anti-doping / Homeland security / Environmental / Fine chemical / Petrochemical / Drug testing / Art museums / Paint / Automobile / Energy / Materials etc QA / QC labs Any GC/MSD with NIST library - need for compound ID
41 Cerno web Collaterals/Support/Contact Info Tech demo: Publications: App Notes: Agilent web Dedicated page: (another one for GC/MSD) Flyer: EN, EN App Notes: EN, EN, EN (polymer), EN (food) Support and Contacts Data acquisition setup: Training video: live demos / visits, anyone?
Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs
Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,
More informationCerno Application Note Extending the Limits of Mass Spectrometry
June Cerno Application Note Extending the Limits of Mass Spectrometry Accurate Mass Compound Identification with Single Quadrupole GC/MS Yongdong Wang I and Harry Prest II Single Quad GC/MS instruments
More informationAgilent 5977A Series GC/MSD System
Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the
More informationCerno Application Note Extending the Limits of Mass Spectrometry
Confident Compound Identification with High Mass Accuracy and Elemental Composition Specific NIST Library Search Identification of unknown compounds by unit mass resolution GC-MS systems essentially relies
More informationMassHunter TOF/QTOF Users Meeting
MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks
More informationMaking Sense of Differences in LCMS Data: Integrated Tools
Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From
More informationIntroducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies
Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading
More informationFinnigan LCQ Advantage MAX
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer
More informationAutomatic Generation of Extract ion Chromatogram for Mass Spectral Peaks with Specific Isotope Labeled Patterns
Cerno Bioscience Poster TPO #260 from ASMS 2007, reformatted for readability Page 1 Automatic Generation of Extract ion Chromatogram for Mass Spectral Peaks with Specific Isotope Labeled Patterns Mark
More informationAn Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining
An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining Dave Weil, Ph.D. and Jim Lau, Ph.D. Typical Method Conditions: 1260 UHPLC
More information4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 alpha-pihp Sample Type: Seized Material Latest Revision: October 30, 2018 Date Received: August 17, 2018 Date of Report: October 30, 2018 1. GENERAL INFORMATION
More informationGAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions
GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are
More informationWALKUP LC/MS FOR PHARMACEUTICAL R&D
Pharmaceutical Workflow Solutions WALKUP LC/MS FOR PHARMACEUTICAL R&D Chemists, Peptide/Protein Chemists, Biologists, and Beyond MASSHUNTER WALKUP A Single User Interface for Robust and Reliable LC/MS
More informationThermo Finnigan LTQ. Specifications
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications
More informationMethod for the Routine Determination of Accurate Masses by Triple Quadrupole Mass Spectrometry
Benchmark Method for the Routine Determination of Accurate Masses by Triple Quadrupole Mass Spectrometry Pedro A. Segura *, Killian Barry, Emmanuel Eysseric, Shawn Gallagher Duval, Philippe Venne and Guillaume
More informationScreening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting
Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting Application Note Authors Angela Smith Henry and Bruce Quimby Agilent
More information5Cl-AKB48 and 5Br-AKB48
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 5Cl-AKB48 and 5Br-AKB48 5Cl-AKB48 Sample Type: Seized Material Latest Revision: May 18 th, 2018 Date Received: February 16 th, 2018 Date of Report: April
More informationAutomated and accurate component detection using reference mass spectra
TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,
More informationAll Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems
All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution
More information2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 25E-NBOH Sample Type: Seized Material Latest Revision: May 18 th, 2018 Date Received: January 12 th, 2018 Date of Report: February 27 th, 2018 1. GENERAL
More informationMassHunter Software Overview
MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A
More informationApplication Note. Authors. Abstract. Introduction. Environmental
Using a Chlorine Filter for Accurate-Mass Data Analysis of Environmental Samples Application Note Environmental Authors Imma Ferrer and E. Michael Thurman Center for Environmental Mass Spectrometry University
More informationAnalysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF
Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,
More informationSeparation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers
Application Note Forensic and Toxicology - Criminalistics Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Using the Agilent 126 Infinity II SFC and Detection by Coupled
More informationUSP<467> residual solvents
Application Note Pharmaceuticals USP residual solvents Applying the Agilent 977A MSD with the Agilent 797A headspace sampler and Agilent 7890B GC Authors Roger L. Firor and Mike Szelewski Agilent Technologies,
More informationWorkflow Using Hyphenated Mass Spectrometry Techniques
Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA chin_meng@agilent.com com February 12, 2009 Page
More information1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 N-ethyl Hexylone Sample Type: Seized Material Latest Revision: May 18 th, 2018 Date Received: February 12 th, 2018 Date of Report: April 19 th, 2018 1.
More informationN-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 5Cl-AB-PINACA Sample Type: Seized Material Latest Revision: October 5, 2018 Date Received: June 6, 2018 Date of Report: October 5, 2018 1. GENERAL INFORMATION
More informationMethyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 MFUBINAC Sample Type: Seized Material Latest Revision: October 30, 2018 Date Received: August 17, 2018 Date of Report: October 30, 2018 1. GENERAL INFORMATION
More informationHigh-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis
High-Resolution Sampling D-LC for Pharmaceutical Impurity Analysis Detection of Impurities Hidden Under the API Peak at Relevant Levels Application Note Small Molecule Pharmaceuticals and Generics Authors
More informationCerno Application Note Extending the Limits of Mass Spectrometry
Creation of Accurate Mass Library for NIST Database Search Novel MS calibration has been shown to enable accurate mass and elemental composition determination on quadrupole GC/MS systems for either molecular
More informationRapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS
Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,
More informationEnhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns
Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Martin Okiro and Robert Wohleb VICI Gig Harbor Group Inc, P.O. Box 2657, Gig Harbor,
More informationKey Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery
Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan
More informationThe Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications
The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded
More informationConstruction and Use of API Single- Quadrupole MS Spectral Libraries.
Paul Zavitsanos Product Marketing Manager September 11, 2003 Construction and Use of API Single- Quadrupole MS Spectral Libraries. Time: 11:00 a.m. EDT Telephone Number: 888-840-7687 International Number:
More informationAnalysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS
Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS Application Note Energy and Fuels - Biofuels Authors Ron Honnold, Ph.D. and Robert Kubas Agilent Technologies, Inc. Santa Clara, CA
More informationThe Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer
The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS Agilent Technologies/Wasson ECE Monomer Analyzer Application Authors Fred Feyerherm 119 Forest Cove Dr. Kingwood, TX
More information4-Methyldiethcathinone (4-MDEC)
NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 4-Methyldiethcathinone (4-MDEC) Sample Type: Seized Material Latest Revision: May 18 th, 2018 Date Received: December 12 th, 2017 Date of Report: February
More informationAgilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity
Agilent 12 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity A case study with degraded omeprazole drug product Application Note Small Molecule
More informationAnalyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.
Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments Application Environmental Authors Jim Lau, Chin-Kai Meng, and Jennifer Gushue Agilent Technologies, Inc. 285 Centerville
More informationAgilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases
Agilent 129 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent
More informationAgilent Technologies LCMS Portfolio
Agilent Technologies LCMS Portfolio Hardware and Software Solutions for the Most Challenging Applications Jean-Francois Roy MS Product Specialist Agilent Technologies 1 Raising the Standard in UHPLC Highest
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationDie Nadel im Heuhaufen
Die Nadel im Heuhaufen Workflow zur Identifizierung unerwarteter Komponenten in LC Q-Tof Daten Umwelt & Lebensmittel Seminar Tour Andreas Reimann Produktspezialist LC-MS Agilent Technologies Instrumentation
More informationAnalysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF
Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TF Application Brief Authors Kevin Rowland 1, Mark Jordi 1, Kai Chen, and Jennifer
More informationIdentification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate
Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and
More informationInterpretation of Organic Spectra. Chem 4361/8361
Interpretation of Organic Spectra Chem 4361/8361 Characteristics of Common Spectrometric Methods H-1 C-13 MS IR/RAMAN UV-VIS ORD/CD X- RAY Radiation type RF RF Not relevant IR UV to visible UV to visible
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis
More informationWhat s New in NIST11 (April 3, 2011)
What s New in NIST11 (April 3, 2011) NIST11 consists of the 2011 release of the NIST/EPA/NIH Electron Ionization (EI) Mass Spectral Database, the NIST MS/MS Database, and the NIST GC Methods and Retention
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationFUTURE CONFIRMATORY CRITERIA
FUTURE CONFIRMATORY CRITERIA Revision CD 2002/657 Marco Blokland, Bjorn Berendsen, Hans Mol, Leen van Ginkel, Saskia Sterk REVISION 2 Revision 2002/657 EU Commission has explicitly asked for a revision
More informationThe new Water Screening PCDL
The new Water Screening PCDL Content and integration in suspect and non-target screening Dr. Thomas Glauner Senior LC/MS Applications Scientist EMEA Market Development Team 1 Accurate mass screening and
More informationGC-CI-MS analysis of TMS derivatives
GC-CI-MS analysis of TMS derivatives This method describes analysis of TMS derivatives with methane chemical ionisation (CI) rather than the more normal electron impact (EI) ionisation. Methane CI is a
More informationbrochure brief 5973Network Mass Selective Detector General Description and Configurations
brochure brief 5973Network Mass Selective Detector This publication provides general technical information about the 5973Network MSDs to accompany the specifications and brochure. The MSD series was originally
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationApplying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC
Applying the Agilent 5977A MSD to the Analysis of USP Residual Solvents with the 7697A Headspace Sampler and 7890B GC Application Note Pharmaceuticals Authors Roger L. Firor and Mike Szelewski Agilent
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationAgilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012
1 Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 Review: Technology for Accurate Mass Analysis: TOF LC/MS Mass measurements accurate to several
More informationThe 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note
The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note Authors Chris Sandy Agilent Technologies Wokingham, Berkshire, UK Jean-Francois Garnier Agilent Technologies
More informationApplication Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract
Detection and identification of impurities in pharmaceutical drugs Computer-assisted extraction, profiling and analysis of Q-TF data for determination of impurities using Agilent Massunter software Application
More informationA Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,
More informationA Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1
More informationLC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note
LC walk-up system using the Agilent 12 Series LC Method Development Solution and Agilent Easy Access software Test of reaction kinetics, column scouting, and impurity checks with one LC system and up to
More informationNew Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology
New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue
More informationMethyl 2-[[1-(5-fluoropentyl)indole-3-carbonyl]amino]-3,3- dimethyl-butanoate
5F-MDMB-PICA Sample Type: Seized Material & Biological Fluid Latest Revision: July 31, 2018 Date of Report: July 31, 2018 Earliest Identification: November 2017 (Seized Material) 1. GENERAL INFORMATION
More informationAchieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer
APPLICATION NOTE 72385 Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer Authors Stephan Meding, Katherine Lovejoy, Martin Ruehl Thermo Fisher Scientific,
More informationAnalysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry
Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry Application Note Food safety Authors Ismael Flores and Carlos Sepulveda Agrolab México Km 7 Carretera Pachuca-Actopan
More informationA Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance
A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,
More informationExpectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the experiment, I expect that you will
More informationGC Analysis of Polybrominated Flame Retardants Application
GC Analysis of Polybrominated Flame Retardants Application Environmental Authors Eberhardt Kuhn, Jason Ellis Agilent Technologies, Inc. 91 Blue Ravine Rd, Folsom, CA 9563 USA Steve Wilbur Agilent Technologies,
More informationMulti-residue GC-MS analysis. Richard Fussell CSL York, UK
Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary
More informationIdentifying Disinfection Byproducts in Treated Water
Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction
More informationApplication Note. Edgar Naegele. Abstract
Fast identification of main drug metabolites by quadrupole time-of-flight LC/MS Measuring accurate MS and MS/MS data with the Agilent 651 Q-TOF LC/MS and identification of main meta-bolites by comparison
More informationAgilent G3212 GC-APCI Source
Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data
More informationSupplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry
Supplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry 1 EM and KDE 1.1 E-step In the E-step, we deal with
More informationANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide
More informationANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 4-Me-TMP (C15H21NO2) methyl-2-(4-methylphenyl)-2-(piperidin-2-yl)acetate
More informationImpurities Sources, Detection and Measurement HPLC-MS Analyses. Dr Courtney Milner Chemical Analysis
Impurities Sources, Detection and Measurement HPLC-MS Analyses Dr Courtney Milner Chemical Analysis Chemical Analysis Integrated Analytical Resource (Physical, Chemical and Microbiological) that has facilities
More informationANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-
Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si ANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-carboxamide
More informationProudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment LCQ Deca XP Plus Improved Ion Optics for Greater Sensitivity and Precision
More informationMassHunter METLIN Metabolite PCD/PCDL Quick Start Guide
MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter
More informationAccelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software
Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software Application ote Drug discovery and development: Metabolite Identifi cation Authors Yuqin Dai,
More informationLC-MS Based Metabolomics
LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile
More informationAuthor. Abstract. Introduction
Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent
More informationBenchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample
APPLICATION NOTE Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample No. AN52889 Authors: Dean Antic, Ph.D., Thermo Fisher Scientific, San Jose, CA, USA WanLi Wei, Senior Engineer,
More informationBIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY
BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY UV/Vis Spectroscopy is a technique that is widely used to characterize, identify and quantify chemical compounds in all fields of analytical chemistry. The
More informationSEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW
SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been
More informationA novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins
TECHNICAL NOTE 39 A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins Author Cristian Cojocariu Thermo Fisher Scientific, Runcorn,
More informationLive Webinar : How to be more Successful with your ACQUITY QDa Detector?
Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the
More informationApplication Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy
Analytical Quantification of Deoxygenated Compounds in Catalytic Reaction Samples as an Evaluation Technique to Detere Reaction Conversion from a Bioderived Oil in Novel Biofuel Testing Application Note
More informationQuantumMCA QuantumNaI QuantumGe QuantumGold
QuantumMCA QuantumNaI QuantumGe QuantumGold Berkeley Nucleonics Corporation (San Rafael, CA) and Princeton Gamma Tech (Princeton, NJ) have partnered to offer gamma spectroscopy with either germanium or
More informationThe Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection
Application Note Small Molecules The Agilent 26 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection Method Development Using Method Scouting Wizard Authors Stefan Bieber Analytical
More informationDetermination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry
Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Application Note Doping Control Authors Prof. Maria Kristina Parr Freie Universität Berlin Institute
More informationGas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326
Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326 with Smart Abilities Enhanced Sensitivity Leads to New GC-MS/MS Possibilities The GCMS-TQ8050 features a new highly efficient detector and three
More informationPesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques
Pesticides e-seminar Series - Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Date: 30 April 2009 Time : 10am Singapore Time For audio, please dial one of the phone numbers listed:
More information[ instrument specifications ]
Designed for leading researchers working at the limits of conventional mass spectrometry capabilities who need to further characterize and define their samples the Waters SYNAPT High Definition MS (HDMS
More informationAnalyst Software. Peptide and Protein Quantitation Tutorial
This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document
More informationTOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.
TOF/QTOF Users Meeting Jim Lau, Agilent Technologies. Agenda Goal Share Best Practices, Develop Network of Agilent Users Today s Topics: Care and Feeding Agilent LCMS Systems Data Acquisition: Optimize
More informationApplication Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors
Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food
More information