Regis Technologies Ion Pair Reagents and Buffers

Size: px
Start display at page:

Download "Regis Technologies Ion Pair Reagents and Buffers"

Transcription

1 egis Technologies Ion Pair eagents and Buffers Ion Pair HPLC greatly extends the applicability of HPLC by making the efficient octadecylsilyl columns amendable to use with ionized or ionizable samples. egis S-Series (for Cations) egis Q-Series (for Anions) The sulfonates are sodium salts that act as an anionic counterion for the separation and resolution of positively charged analytes. The sulfonates are available as ion pair concentrates: premixed 0. M solutions of alkyl sulfonates. When diluted to L with HPLC-grade water, a 0mL bottle forms a 0.00 M solution. Five 0mL Bottles 00mL Bottle Description Cat. No. Cat. No. S Pentanesulfonate S Hexanesulfonate S Heptanesulfonate S8 ctanesulfonate S Dodecanesulfonate Method Development Kit S-Series 0mL of S (,,, 8, and ) 000 The Q-series is comprised of quaternary alkyltriethylamines that can be used for the resolution of negatively charged species. This unique set of cationic reagents was developed to complement the Sulfonate Series (S-series). The Quaternary Alkyltriethylamines are available as ion pair concentrates: premixed 0. M solutions of alkyl amines. When diluted to L with HPLC-grade water, a 0mL bottle forms a 0.00 M buffered solution. Five 0mL Bottles 00mL Bottle Description Cat. No. Cat. No. Q Pentyl (TEA) Q Hexyl (TEA) Q Heptyl (TEA) Q8 ctyl (TEA) Q Dodecyl (TEA) Method Development Kit Description Cat. No. Q-Series 0mL of Q (,,, 8, and ) 000 Bulk Ion Pair eagents For Cations Cat. No. Description Grams 00 -Pentanesulfonate, sodium salt g 0 00g 00 -Hexanesulfonate, sodium salt g 0 00g 00 -Heptanesulfonate, sodium salt g 0 00g 008 -ctanesulfonate, sodium salt g 08 00g 00 -Dodecanesulfonate, sodium salt g 00 g For Anions 800 Tetrabutylammonium Phosphate 0mL 0.M, ph. 800 Tetrabutylammonium Phosphate 00mL 0.M, ph. Tech Tip: Guidelines to developing a successful method using ion pair reagents: Select a column endcapped DS (octadecylsilyl) is most common. Use only HPLC-grade water and chromatography grade reagents in mobile phase preparation. Choose the mobile phase components and concentrations that give the best separation. If nonionic components are present in the sample, optimize the resolution prior to attempting ionic separations. Select the appropriate ion pair series to provide the necessary counterion. Use the Q-series for acidic compounds and the S-series for basic compounds. Through a process of elimination, choose the alkyl chain length which results in the best separation. nce the reagent has been selected, adjust the ph of the mobile phase to maximize resolution. Because slight modification of ph can profoundly effect retention and selectivity, make all adjustments in small increments and monitor carefully. Ideally, the ion pair reagent concentration in the mobile phase should be 0.00M. However, small adjustments in reagent concentration may increase retention slightly and optimize the separation. For a complete list of egis reagents, please contact Chrom Tech in MN sales@chromtech.com

2 Agilent Zorbax New! Zorbax apid esolution (HT) High Throughput Columns Up to 9% decrease in analysis time Great resolution Extended ph range, ph to 9 A better way to faster separations! All Agilent Zorbax columns are uniquely optimized for specific applications. ur newest Zorbax columns, apid esolution HT, are packed with totally porous.8µm particles. These columns are optimized for ultra-fast HPLC separations with more resolving power for small molecules. The typical particle size of traditional HPLC columns is µm, but in the past,.0 to.µm particles offered better efficiency with short column lengths. Now, our new apid esolution HT columns with.8µm particles nearly double laboratory productivity compared with columns containing.µm packings. You get even higher resolution and efficiency in very short columns ( to 0mm) ideal for sample screening, LC/MS and many routine analyses. apid esolution HT Columns,.8µm Dimensions StableBond Eclipse (mm) Format SB-C8 XDB-C8. x 0 column x 0 cartridge x 0 cartridge x cartridge x 0 column x 0 cartridge x 0 cartridge x cartridge apid esolution HT Cartridge Hardware Kit Kit includes: () end-fitting assemblies; () 0mm holder; () 0mm holder; () mm holder A B C D Column Conditions Zorbax SB-C8: Mobile Phase: 0% 0mM Na HP, ph.8: 0% ACN Temperature: Ambient Detection: 0nm. Estradiol. Ethynylestradiol. Dienestrol. Norethindrone Flow Analysis Column ate Time Time Dimensions (ml/min) s (,) (min) Savings A.. x 0mm, µm B.. x 00mm,.µm.0.. % C.. x 0mm,.8µm.0.. 8% D.. x 0mm,.8µm.0.. 9% esolution between peaks and Zorbax Method Development (ph -) Low ph - Zorbax StableBond Start method development at low ph, where silanols on a P-HPLC column are protonated. This minimizes peak tailing by eliminating silanol/base interactions. At low ph, basic compounds are positively charged and their retention may be reduced. Acidic compounds may be protonated and have increased retention. etention times are usually stable with small changes in ph, producing a robust method. Volatile mobile phase additives, such as formic acid or trifluoroacetic acid (TFA), are often used at low ph with LC/MS. Mid ph -8 Zorbax Eclipse XDB or Bonus-P Develop methods at ph s at least ph unit above or below the pka to minimiz changes in retention with small changes in ph. Some silica surface H groups become - above ph to ; tailing interactions may be possible. Minimize interaction by selecting an end-capped column, using additives such as TEA (less desirable) or using polar-linked bonded phases. lica breakdown is prevented by innovative bonding chemistry, heavy endcapping and use of x-sil. High ph 8- Extend C8 In this region, basic compounds may be in their free base form. Increased retention and resolution of basic compounds are likely. etention changes little in this region-thus robust methods can be developed. lica breakdown is prevented by innovative bidentate column chemistry, heavy endcapping, use for x-sil and optimum mobile phase. Ammonium hydroxide is an excellent volatile mobile phase modifier at high ph in MN sales@chromtech.com

3 Agilent Zorbax StableBond 80Å Long column lifetime and best reproducibility for low ph separations down to ph! Stable column chemistry allows use at high temperature and low ph without degradation Excellent first choice for method development StableBond packing materials are not endcapped in order to provide exceptional stability and to maximize lifetime and reproducibility under acidic mobile phase conditions. Zorbax StableBond columns are compatible with all common mobile phases including very high aqueous mobile phases. Polar compounds can be analyzed with excellent reproducibility and peak shape because SB-Aq columns have a hydrophilic surface that inhibits phase collapse, even with 00% aqueous mobile phases. Zorbax StableBond Column Specifications Phase ze Area Limits ange Endcapped Load SB-C8 80Å 80m /g 90 C No 0% SB-C8 80Å 80m /g 80 C No.% SB-C 80Å 80m /g 80 C No.0% SB-CN 80Å 80m /g 80 C No.0% SB-Phenyl 80Å 80m /g 80 C No.% SB-Aq 80Å 80m /g 80 C No Proprietary StableBond columns are designed for optimal use at low ph. At ph -8, highest column stability for all silica-based columns is obtained by operating at temperatures <0 C and using low buffer concentrations in the range of M. At mid-range ph, Eclipse XDB and Bonus-P are recommended. 80Å Zorbax StableBond Cartridge Columns Dimensions Particle (USP L) (USP L) (mm) ze (µm) SB-C8 SB-C8. x x x x x x.0, 0/pk x x Cartridge holder Hardware kit requires cartridge holder 0-8 requires hardware kit Å Zorbax StableBond Columns Dimensions Particle (USP L) (USP L) (USP L0) (USP L) (mm) ze (µm) SB-C8 SB-C8 SB-CN SB-C SB-Phenyl SB-Aq. x x x x x x x x x x x x x x x x x x x x x x., /pk x., /pk Guard Hardware Kit (fits both. x. and. x. cartridges) Hardware kit in MN sales@chromtech.com 9

4 Agilent Zorbax StableBond 00Å Designed for the acidic ph mobile phases used in peptide and protein separations Improve hydrophobic peptide separations Applications: Peptides, biopharmaceuticals, hydrophobic peptides, proteins at low ph Zorbax 00StableBond columns are an ideal choice for the reproducible separations of proteins and peptides for two key reasons. First, wide-pore, 00Å columns are necessary for an efficient separation of proteins and peptides, or other large molecules, in order to allow these analytes to completely access the, 00SB-C8, SB-C, SB-C8, SB-CN, Nase. Insulin. Cytochrome C. Lysozyme. Parvalbumin, The 00SB-C8, C8, C and CN bonded phases all provide a different separation of this group of polypeptides. This adds an important parameter for quickly optimizing protein separations. The 00SB-CN column offers unique selectivity for more hydrophilic polypeptides. Column Conditions Zorbax 00SB Mobile phase: Linear gradient, -0% B in 0 min. Flow rate:.0ml/min Temperature: 0 C µg each protein. CD. Myoglobin 8. Carbonic Anhydrase 9. S-00β 0. S-00α bonded phase. Second, 00StableBond columns are unmatched in their durability at low ph, such as with the TFA containing mobile phases typically used. 00StableBond columns can also be sued with formic acid and acetic acid mobile phase modifiers. Zorbax StableBond Column Specifications Phase ze Area Limits ange Endcapped Load SB-C8 00Å m /g 90 C No.8% SB-C8 00Å m /g 80 C No.% SB-C 00Å m /g 80 C No.% SB-CN 00Å m /g 80 C No.% StableBond columns are designed for optimal use at low ph. At ph -8, highest column stability for all silica-based columns is obtained by operating at temperatures <0 C and using low buffer concentrations in the range of M. At mid-range ph, Eclipse XDB and Bonus-P are recommended. 00Å Zorbax StableBond Columns Dimensions Particle (USP L) (USP L) (USP L0) (mm) ze (µm) 00SB-C8 00SB-C8 00SB-CN SB-C. x x x x x x x x x x x x x x x, /pk x., /pk x., /pk Guard Hardware Kit (fits both. x. and. x. cartridges) Hardware kit Zorbax Poroshell 00SB Columns for Bioanalytical Chemistry Porous Shell SLID CE µm The revolutionary new Poroshell µm particle combines a solid core with a 00Å porous surface layer bonded with SB-C8. The result is a highly efficient particle for rapid, high-resolution separations of proteins and other large molecules. Large and/or heterogeneous proteins have more complex interactions with the surface of the column packing and show improved peak shapes and resolution on superficially porous particles bonded with shorter phases such as C and C8. The simplified interaction of protein with the surface of the packing is the reason for improved chromatography. For very large, heterogeneous proteins, Zorbax Poroshell C or C8 columns give the best peak shape in a separation 00Å Zorbax StableBond Columns Dimensions Particle Poroshell Poroshell Poroshell (mm) ze (µm) 00SB-C8 00SB-C8 00SB-C. x x x., /pk Guard Hardware Kit (fits both. x. and. x. cartridges) Hardware kit in MN sales@chromtech.com

5 Agilent Zorbax Eclipse XDB Long column life at mid ph with extra dense bonding (XDB) and double endcapping Complementary selectivity to StableBond, Bonus-P or Extend columns Uses Zorbax x-sil silica with uniform wall thickness for better column life at higher ph ph range: recommended to 8, maximum to 9 Zorbax Eclipse XDB Column Specifications Phase ze Area Limits ange Endcapped Load XDB-C8 80Å 80m /g 0 C Double 0% XDB-C8 80Å 80m /g 0 C Double.% XDB-Phenyl 80Å 80m /g 0 C Double.% Zorbax Eclipse XDB Columns Dimensions Particle (USP L) (USP L) (USP L) (mm) ze (µm) XDB-C8 XDB-C8 XDB-Phenyl. x x x x x x x x x x x x x x x x x x x x, /pk Good Peak Shape for Acids, Bases, and Neutrals on Zorbax Eclipse XDB at Mid-pH. Uracil. Butyl Paraben. Propranolol. Naphthalene. Dipropyl Phthalate. Acenaphthene. Amitriptyline 0 0 In the mid-ph region, residual silanols can interact more strongly with analytes, resulting in asymmetric peaks. The Eclipse XDB column provides good peak shape in this difficult ph range. Column Conditions Zorbax Eclipse XDB-C8 Mobile phase: % 0mM NaH P, ph.0, % MeH Flow rate:.0ml/min Temperature: C Detection: UV nm Column Stability Testing. x., /pk x., /pk Eclipse XDB-C8 (Sol-Type) After 8 column volumes Guard Hardware Kit (fits both. x. and. x. cartridges) Hardware kit Zorbax Eclipse XDB Cartridge Columns Dimensions Particle (USP L) (USP L) (mm) ze (µm) XDB-C8 XDB-C8. x x x x x x.0, 0/pk x x x Cartridge holder Hardware kit requires cartridge holder 0-8 requires hardware kit , Column:. x 0mm, µm Mobile Phase: 0% ACN, 0% 0mM phosphate buffer, ph.0 Flow rate:.ml/min Temperature: 0 C Water Symmetry C8 (l-type) After 8 column volumes. Uracil. Nortriptyline. Doxepin. Amitriptyline. Trimipramine Double endcapping, dense bonding, and the durable x-sil particles (sol-type) combine to provide long lifetime at ph.0 when compared to single endcapped sil-gel columns, such as the Waters Symmetry C8 column used here. The conditions used for this test high temperature (0 C) and high salt concentration (0mM), accelerate the dissolution of silica, causing premature failure of the sil-gel type column in MN sales@chromtech.com

6 Agilent Zorbax Bonus-P Excellent peak shape for challenging basic compounds at low and mid ph Unique reversed-phase selectivity Novel bonding technology with embedded polar group and steric protection Usable in 00% aqueous mobile phases The Agilent Zorbax Bonus-P column has a polar amide group embedded in a long alkyl chain. This novel bonding reduces interactions between basic compounds and the silica support, improving peak shape for the most difficult basic compounds. Peak shape and column lifetime are further improbed by triple endcapping. In addition, diisopropyl side groups provide steric protection against acid hydrolysis for good lifetime at low ph. The Bonus-P column provides an alternate selectivity to C8 and C8 alkyl bonded phases. Zorbax Bonus-P Column Specifications Phase ze Area Limits ange Endcapped Load Bonus-P 80Å 80m /g 0 C Triple 9.% Zorbax Bonus-P Columns Particle Bonus-P ze (µm) Cat. No.. x 0mm x 0mm x 0mm x 00mm x mm x 0mm x 0mm x 00mm x 0mm x 0mm x 0mm x 0mm x mm, /pk 8-9 Guard Cartridges (requires hardware kit ). x.mm, /pk x.mm, /pk 8-98 Guard Hardware Kit (fits. and.mm ID cartridges) Hardware kit Bonus-P Can Provide Alternative Selectivity to Alkyl Phases. Prometryne. Tebuthion. Atrazine. Propazine Bonus-P Alkyl-C8 Column Conditions Zorbax Bonus-P Column:. x 0mm Instrument: Agilent 00 Mobile phase: MeH: 0.% TFA (0:0) Flow rate: ml/min. Temperature: Ambient Inj.: µl UV: nm For low ph work, a TFA mobile phase is often preferred over phosphate and is compatible with LC/MS. Dacthal. Diuron. Propanil Bonus-P Provides Excellent Peak Shape for Anorectics at Mid-ange. Phentermine pka 0.. Fenfluramine pka 9.. Impurity Column Conditions Zorbax Bonus-P Columns:. x 0mm Mobile phase: mm K HP, ph./meh:acn (0:0), / Flow rate: ml/min. Inj.: µl UV: nm Anorectics ( Fen-phen ) guard hardware kit shown with guard cartridge and column in MN sales@chromtech.com

7 Agilent Zorbax Extend-C8 High efficiency and long life at high ph up to ph. Unique bidentate bonding and double endcapping provides high ph stability More efficiency and better peak shape than polymerbased columns Improve retention, resolution and peak shape of basic compounds High sensitivity for LC/MS separations of peptides.0e.0e.0e.0e.0e LC/MS Analysis of Angiotensin 80Å Extend-C8 AII + AIII AI Angiotensin I Max: min m/z A. Acidic Conditions: A: 0.% TFA in water B: 0.08% TFA in 80% acetonitrile (ACN).0E C8 lica Support C8 New bidentate C8-C8 bonding for Extend-C8 bonded phase The Agilent Zorbax Extend-C8 column uses a new bidentate C8- C8 column bonding technology to make high ph separations a good choice with a silica-based column. At high ph, non-charged basic compounds will not interact with the silica, so it is possible to do separations with high efficiency, superior peak shape and improved resolution. Some of the mobile phase buffer options for high ph include triethylamine, pyrrolidine, glycine, borate and ammonium hydroxide. Ammonium hydroxide at ph 0. is an excellent mobile phase modifier for the LC/MS of peptides and small molecules with improved sensitivity compared with TFA containing mobile phase at low ph. Zorbax Extend-C8 Column Specifications Phase ze Area Limits ange Endcapped Load Extend-C8 80m /g 0 C.0 -. Double.% Temperature limits are 0 C up to ph 8, 0 C for ph Å or 00Å, as indicated in ordering information table below. Zorbax Extend-C8 Columns Dimensions Particle 80Å 00Å (mm) ze (µm) Extend-C8 Extend-C8. x x x x x x x x x x x x x x x x x, /pk 8-9 Guard Cartridges (requires hardware kit ). x., /pk x., /pk Guard Hardware Kit (fits. and.mm ID cartridges) Hardware kit E 00 Angiotensin I AIII.0E 80 + Max: AII 0.0E 0 + AI.0E min m/z B. Basic Conditions: A: 0mM NHH in water B: 0mM NHH in 80% ACN Both small and large peptides demonstrate selectivity changes at high and low ph. At high ph, due to a change in charge, all three Angiotensins can be resolved. In addition, the spectral clarity of Angiotensin I is dramatically improved at high ph with the ammounium hydroxide mobile phase. The Extend-C8 column can also be used for the analysis of small peptides at high ph. Column Conditions Zorbax 80Å Extend-C8 Column:. x 0mm, µm, Flow rate: 0.mL/min Temperature: C Mobile phase: as indicated Gradient: -0% B in minutes LC/MS: Pos. Ion ESI-Vf 0V, Vcap. kv, N - psi, LPM, C Angiotensin I, II, III;.µL sample (0 pmol each) Angiotensin I: Asp-Arg-Val-Tyr-IIe-His-Pro-Phe-His-Leu Angiotensin I: Asp-Arg-Val-Tyr-IIe-His-Pro-Phe Angiotensin I: Arg-Val-Tyr-IIe-His-Pro-Phe Extend-C8 Provides Good Peak Shape at Low ph These basic compounds are separated on the Extend-C8 at low ph with excellent peak shape. The Extend-C8 column can be used at high and low ph. Column Conditions Zorbax Extend-C8 Column:. x 0mm, µm, 0-90 Mobile phase: 80% mm NaH P, ph.0, 0% MeH Flow rate:.0ml/min Temperature: C Detection: UV nm. Theobromine. Dimethylxanthine. Theophylline. Caffeine Pseudoephedrine and scopolamine are difficult to retain at low and mid ph. Pseudoephedrine is often analyzed by ion exchange methods. The Extend-C8 column retains these compounds in a noncharged ph form at high ph and improves resolution in MN sales@chromtech.com 0 Improved etention, esolution and Peak Shape of Basic Antihistamines on Extend-C8 at High ph Column Conditions Zorbax Extend-C8 Column:. x 0mm, µm, 0-90 Mobile phase: ph : 0% 0mM Na HP, 0% MeH ph : 0% 0mM TEA, 0% MeH Flow rate:.0ml/min Temperature: Ambient Detection: UV nm. Maleate. Chlorpheniramine. Scopolamine. Triprolidine. Pseudoephedrine. Diphenhydramine. Doxylamine, ph

8 Agilent Zorbax Columns Zorbax Gel Filtration Columns Zorbax Ion Exchange Columns apid separations and extended column life time often twice that of other size exclusion columns High recovery for most proteins (>90%) Usable with organic modifiers and denaturants ph range of The silica surface of the Zorbax Gel Filtration columns is stabilized with zirconia, then coated with a monolayer diol phase providing a broad ph range of -8 a highly reproducible, hydrophilic column. Zorbax Gel Filtration Column Specifications Bonded Pore Particle MW Surface Phase ze ze ange Area GF-0 0Å µm,000-00,000 0m /g GF-0 00Å µm 0, ,000 0m /g Additional Specifications for Both Gel Filtration Columns Bonded Phase ph ange Flow ate Max Pressure GF-0 and GF <.0mL/min,000 psi Zorbax ion exchange columns (0Å SAX and 00Å SCX) use Zorbax SIL porous silica microspheres as the stationary phase support; ion exchange groups are attached to a diol backbone. These columns provides highly efficient, rapid separations (pressure limit,000 psi). SCX uses aromatic sulfonic acid SAX uses a trifunctional quaternary amine Typical Applications: SCX basic water soluble compounds SAX aromatic carboxylic acids, aliphatic carboxylic acids, and sulfonic acids Zorbax Ion Exchange Columns Bonded Pore Particle Surface ph Bonded Phase ze ze Area ange Functionality SCX 00Å µm 0m /g Sulfonic acid SAX 0Å µm 00m /g Quaternary amine Separation of a Protein Mixture Zorbax GF-0 Column 8 0 Column Conditions Zorbax GF-0 Column: 9. x 0mm Flow rate: ml/min Eluent: 0mM NaCl/0mM KCl/ 0mM Na HP, ph.0 Detection: UV 0 nm. Mouse IgM 900,000 Da. Bovine Thyroglobulin 0,000 Da. Sweet Potato ß-Amylase 00,000 Da. Bovine Serum Albumin,000 Da. Chicken Albumin,000 Da. Bovine NAse,00 Da. Azide Da Cough-cold emedies Zorbax SCX Column Conditions Zorbax SCX Column:. x 0mm Flow rate: ml/min Eluent: 0. M NaH P, ph. Temperature: 0 C Detection: UV 0 nm. Pyrilamine. Theophylline. Glyceryl Guaicolate. Caffeine. Phenylephrine High-Speed ze Exclusion Separation Zorbax GF-0 Column BSA and BSA Dimers (duplicate injections) 0 Column Conditions Zorbax GF-0 Column: 9. x 0mm Flow rate: ml/min Eluent: PBS, ph. Detection: UV 0 nm Temperature: Ambient. BSA dimer. BSA monomer. Azide Zorbax Gel Filtration Columns Dimensions 0Å 00Å (mm) GF-0 GF-0 9. x x x, /pk x., /pk Guard Hardware Kit Hardware kit for 9. ID Hardware kit for. ID Zorbax Ion Exchange Columns Dimensions (mm) SAX (0Å) SCX (00Å) 9. x x x x x x x Guard Cartridges, /pk (requires hardware kit ). x Guard Hardware Kit Hardware kit in MN sales@chromtech.com

9 Agilent Hypersil Hypersil eversed Phase Columns Hypersil lica Normal Phase Columns Hypersil BDS is both base deactivated and endcapped to improve peak shapes of basic solutes by minimizing interaction with unreacted silanols. Hypersil DS, a very popular packing, adds a monolayer of octadecyl silane (C8) to the Hypersil lica support. Columns are endcapped to reduce silanol interaction. For less retention with similar selectivity, Hypersil MS columns provide a monolayer of dimethyloctylsilane (C8 alkyl chain). eversed Phase Cartridge Columns Cat. No. Description 99BD- BDS-C8,.0µm,.0 x mm 99BD- BDS-C8,.0µm,.0 x mm 99BD- BDS-C8,.0µm,.0 x mm 99B- BDS-C8,.0µm,.0 x 00mm 99B-8 BDS-C8,.0µm,.0 x 0mm 99BD- BDS-C8,.0µm,.0 x mm 99BD-8 BDS-C8,.0µm,.0 x 0mm 99B- BDS-C8,.0µm,.0 x mm 99BD-8 BDS-C8,.0µm,. x 0mm 99BD-9 BDS-C8,.0µm,. x 0mm 998- DS,.0µm,.0 x mm 99D- DS,.0µm,.0 x 0mm 99D- DS,.0µm,.0 x 00mm 998- DS,.0µm,.0 x mm DS,.0µm,.0 x 0mm 99D- DS,.0µm,.0 x mm 99D-8 DS,.0µm,.0 x 0mm DS,.0µm,. x 0mm DS,.0µm,. x 0mm 99B8- BDS-C8,.0µm,.0 x mm 99B8-8 BDS-C8,.0µm,.0 x 0mm 99B8- BDS-C8,.0µm,.0 x mm 99B8- BDS-C8,.0µm,.0 x mm Agilent Cartridge Hardware 0-8 Agilent cartridge hardware eversed Phase Stainless Steel Columns 99BD- BDS-C8,.0µm,. x 00mm 99BD-8 BDS-C8,.0µm,. x 0mm 99BD- DS,.0µm,.0 x mm 99D- DS,.0µm,. x 00mm 99D- DS,.0µm,. x 0mm 99D- DS,.0µm,. x 00mm 99D- DS,.0µm,. x 00mm 99D- DS,.0µm,. x 00mm 99D- DS,.0µm,. x 00mm DS,.0µm,. x 0mm 99M- MS,.0µm,. x 00mm 99M- MS,.0µm,. x 00mm 99M- MS,.0µm,. x 00mm Hypersil eversed Phase Guard Cartridge Columns 99KT-0 DS,.0µm,. x 0mm, /pk DS,.0µm,.0 x mm, 0/pk 99KT-0 DS,.0µm,.0 x 0mm, 0/pk 99KT- MS,.0µm,. x 0mm, /pk 99KT- MS,.0µm,.0 x 0mm, /pk 99BD-0 BDS,.0µm,.0 x mm, 0/pk Agilent Guard Cartridge Hardware 9900CH-00 Cartridge hardware for.mm,.mm ID Hypersil silica columns from Agilent combine a strong, high-purity silica and Agilent s superior packing processes. The strength and reproducibility of these silica particles are also available in an amino phase, Hypersil APS, for normal phase chromatography. Normal Phase Guard Cartridge Columns Cat. No. Description 99AP- Hypersil APS,.0µm,. x 00mm 99AP- Hypersil APS,.0µm,. x 00mm 99AP- Hypersil APS,.0µm,. x 00mm 99SI- Hypersil,.0µm,. x 00mm 99SI- Hypersil,.0µm,. x 00mm 99SI- Hypersil,.0µm,. x 00mm 99SI- Hypersil,.0µm,. x 00mm Normal Phase Guard Cartridge Columns 99KT- Hypersil APS,.0µm,. x 0mm, /pk 99KT- Hypersil APS,.0µm,.0 x 0mm, /pk 99KT- Hypersil,.0µm,. x 0mm, /pk 99KT- Hypersil,.0µm,.0 x 0mm, /pk Agilent Guard Cartridge Hardware 9900CH-00 Cartridge hardware for.mm,.mm ID Column Identification Module (CIM) Attached to an LC column, the column identification module (CIM) communicates with the Agilent 00 Series control module and Agilent ChemStation through a built-in read/write device. Column usage data including serial and batch numbers, dimensions, particle size, packing material and number of injections is recorded electronically in the module (pre-recorded before shipment of Agilent s CIM HPLC columns). You can also record method, plate number, installation date, operator name and other data as needed. With constant updating, column information is always current. Automatic column tracking enhances the Agilent 00 Series features for meeting GLP, cgmp and quality standard requirements, and for achieving fast trouble free validation. Cartridge Columns with CIM Cat. No. Description 98BD- BDS-C8 w/cim,.0µm,.0 x 00mm 98BD-8 BDS-C8 w/cim,.0µm,.0 x 0mm 988- DS w/cim,.0µm,.0 x mm DS w/cim,.0µm,.0 x 0mm Stainless Steel Columns with CIM 988- DS w/cim,.0µm,. x 00mm 988- DS w/cim,.0µm,. x 00mm in MN sales@chromtech.com

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009 A Look at Column Choices Does one-size-fit-all? Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009 Seminar utline lica Surface Chemistry & Physical Characteristics ti lica Bonding

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC Slide 4 001284P1.PPT Seminar Outline 1. Gel-filtration separations by SEC 2. Developing methods for protein and peptide separations

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters Application Angelika Gratzfeld-Huesgen Abstract This application has been verified using an Agilent

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

ION PAIRING REAGENTS AND BUFFERS

ION PAIRING REAGENTS AND BUFFERS ON PRNG REGENTS ND UFFERS ULTRPURE ON PRNG REGENTS ND UFFERS The dvantages of on Pair hromatography on Pair hromatography is a method for improving the separation of charged analytes. n the resolution

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies HPLC Method Development with Eclipse Plus: Standard Practices and New Columns Agilent Technologies What are Some Standard Method Development Practices?. Follow preferred method development scheme and do

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

Does one-size-fit-all?

Does one-size-fit-all? A Look at Column Choices: Does one-size-fit-all? Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 Separation Techniques Hydro - philic Volatile

More information

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Agilent ZORBAX Column Selection Guide for HPLC Here it is your single

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

HPLC Method Development: Standard Practices and New Columns

HPLC Method Development: Standard Practices and New Columns HPLC Method Development: Standard Practices and New Columns Edward Kim Application Engineer Agilent Technologies, Inc. March 8, 29 What are Some Standard Method Development Practices?. Follow preferred

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles Stephanie Schuster 1, Barry Boyes 1,2, and Darryl Johnson 2 1 Advanced Materials Technology,

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

LC Column Troubleshooting. Do you have an equivalent column for my LC column? LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

Superficially Porous Silica Particles with Wide Pores for Biomolecular Separations

Superficially Porous Silica Particles with Wide Pores for Biomolecular Separations Superficially Porous Silica Particles with Wide Pores for Biomolecular Separations B. M. Wagner, S. A. Schuster, B. E. Boyes, J. J. Kirkland Advanced Materials Technology, Inc. Wilmington, DE, USA Study

More information

Reversed Phase Chromatography: Mobile phase Considerations

Reversed Phase Chromatography: Mobile phase Considerations Reversed Phase: Mobile Phase Considerations Dr. www.forumsci.co.il/hplc Example of a Reversed Phase Method with UV Detection 1 Chromatographic Process B+A Mobile phase Elution through the Column-movie

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007 HPLC Method Development: Standard Practices and New Columns Agilent Technologies February 7 What are Some Standard Method Development Practices?. Follow preferred method development scheme and do hands-on

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion HPLC Columns Agilent for Small Molecule InfinityLab Poroshell 0 ZORBAX Eclipse Plus ZORBAX Eclipse XDB ZORBAX 80Å StableBond ZORBAX 80Å Extend-C8 ZORBAX Bonus-RP ZORBAX Eclipse PAH ZORBAX HILIC Plus ZORBAX

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

A Look at Agilent HPLC Columns Choices

A Look at Agilent HPLC Columns Choices A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

RP C18 column with feature of a silanol group

RP C18 column with feature of a silanol group RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

A C18 Silica Column With Exceptional Temperature and ph Stability

A C18 Silica Column With Exceptional Temperature and ph Stability A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies,

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

High Resolution Fast LC

High Resolution Fast LC High Resolution Fast LC Easier Than You Think Rita Steed LC Columns Application Engineer May 9, 2013 What is High Resolution Fast LC? Maintain Resolution with Faster Run Time Increased Resolution with

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-exyl Columns to Separate Estrogens Application Note Pharmaceutical, Environmental Authors John W. enderson Jr. and William J. Long Agilent

More information

The Theory of HPLC. Ion Pair Chromatography

The Theory of HPLC. Ion Pair Chromatography The Theory of HPLC Ion Pair Chromatography i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual.

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

Ronald E. Majors, Ph.D. Product Marketing Specialist Consumables and Accessories Business Unit May 31, 2000

Ronald E. Majors, Ph.D. Product Marketing Specialist Consumables and Accessories Business Unit May 31, 2000 Ronald E. Majors, Ph.D. Product Marketing Specialist Consumables and Accessories Business Unit May 31, 2000 Logical Method Development for Small Molecular Weight Ionizable Compounds using RP-HPLC 11:00

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion

More information

Tips and tricks to increase HPLC column lifetime. Dr. Frank Michel

Tips and tricks to increase HPLC column lifetime. Dr. Frank Michel Tips and tricks to increase HPLC column lifetime Dr. Frank Michel Overview How to influence HPLC column life time? HPLC method Helpful accessories Best practice 2 HPLC Method Mobile Phase Mobile phase

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

NOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution

NOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution Having trouble applying size exclusion chromatography to peptides under 1, Da? What if there was a size exclusion column specifically designed for small protein and peptide separations? Sepax Zenix SEC-8

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

Strength in Technology

Strength in Technology Strength in Technology Fortis C8 Excellent Peak Shapes Superb Quantitation ph Range - Fully Scalable 3,5,0μ C8 7% Fortis C8 is designed to provide characteristics which will aid in increased productivity

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information