Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

Size: px
Start display at page:

Download "Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251"

Transcription

1 Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

2

3 with Smart Technologies Smart Productivity, Smart Operation, Smart Performance Finally, a triple quadrupole GCMS Smart enough for everyday use in your laboratory. GCMS-QP2010 Ultra GCMS-QP2010 SE GCMS-TQ8040 LCMS-8030 LCMS-8040 LCMS-8050 LCMS-2020 LCMS-IT-TOF imscope MALDI-7090

4 The Shimadzu GCMS-TQ8040 is the first triple quadrupole with Smart Productivity for high efficiency sample throughput, Smart Operation for quick and easy method development, and Smart Performance for low detection limits and Scan/MRM. These 3 smart technologies contribute to Smart MRM, and provide the most accurate, cost effective, and easy-to-use triple quadrupole GCMS you have ever imagined. This new firmware protocol enables MRM analysis s with up to 32,768 transitions in a single analysis. A simultaneous analysis can be performed with a conventionally difficult number of components, dramatically increasing productivity. P. 6 to Smart Productivity 4

5 GC-MS/MS analysis requires multiple settings that can be confusing to the average operator. With Smart MRM, the GCMS-TQ8040 software sets the analytical conditions automatically, making method development painless, fast, and easy. P. 8 to Smart Operation The exceptionally efficient ion source and collision cell provide low detection limits. High speed scanning control Advanced Scanning Speed Protocol, or ASSP and simultaneous Scan/MRM analysis mode provides high quality library searchable fragmentation spectra, and accurate low-level quantitative data in a single analysis. P. 12 to Smart Performance Gas Chromatograph Mass Spectrometer 5

6 Typical Analysis MRM method 1 MRM method 2 Simultaneous Analysis MRM method Simultaneous Analysis MRM method method Simultaneous Analysis MRM method 40min Innovative Technologies that Improve Accuracy and Throughput Thanks to two new technologies, the GCMS-TQ8040 enables high-sensitivity, high-precision analyses, even in simultaneous analyses with more than 400 components. For the first new technology, a new firmware protocol was introduced. As a result, data loading efficiency is improved, enabling MRM analysis with up to 32,768 transitions in a single analysis. For the second, Smart MRM was newly incorporated into the software. This method creation function automatically sets the optimal measurement time for each component. Data is only acquired for the elution time for the target components, so more components can be analyzed simultaneously than with previous models, without compromising sensitivity even in multi-component simultaneous analyses. While 400 pesticide components are conventionally separated for measurement in two or three methods, they can be aggregated by the GCMS-TQ8040 into a single method, so the number of analysis cycles can be significantly reduced ( 1,000,000) Simultaneous Analysis of 439 Pesticides Using UFMS and Smart MRM ( 1,000) > > > ( 10,000) > > > ( 1,000) > > > ( 100) > > > Fenthion %RSD = 4.16% Pyributicarb %RSD = 2.39% Iprodione %RSD = 4.54% Indoxacarb %RSD = 4.03% Mass chromatogram and %RSD (5 ppb) 6

7 120 min MRM method 3 40min 80min 120min Twin Line MS System Eliminates the Need to Vent the MS The GCMS-TQ8040 is capable of accepting installation of two narrow-bore capillary columns into the MS simultaneously. This allows you to switch applications without venting the MS. Simply decide which column is best for your analysis and choose the associated injection port. Twin Line MS System 140> > > > Column 1 (SH-Rxi-5Sil MS) Column 2 (SH-Rtx-200 MS) Methamidophos in Ginger (10 ppb), Analyzed on Two Dissimilar Columns Using Smart MRM CID gas control is a method parameter, allowing acquisition of GC-MS and GC-MS/MS data in the same batch. By coupling this with the Twin Line MS System, analysis of VOCs by SIM and analysis of pesticide by MRM is possible in a single batch without venting the MS. SIM GC-MS (CID gas Off) MRM GC-MS/MS (CID gas On) Run SQ and TQ Methods in a Single Sequence *) The Twin Line MS System requires an optional installation kit and is limited to certain column dimensions. Gas Chromatograph Mass Spectrometer 7

8 Simplified GC-MS/MS method development Smart MRM makes method development quick and easy. Whether starting from scratch to optimize transitions and collision energies for new compounds, or starting from an MRM database of known target analytes to build a custom MRM method, Smart MRM takes the stress and difficulty out of method development. MRM Optimization Tool Optimize MRM Transitions Automatically Determining and optimizing MRM transitions for new compounds can require significant development time. The MRM Optimization Tool automates the process by collecting product ion scan data and finding the optimum collision energy for each transition. Once established, the transitions are registered to one of the Shimadzu Smart Database files, and the MRM or Scan/MRM methods are created using Smart MRM. 8

9 Smart Database Compounds and Optimized Transitions The Shimadzu Smart Database is a database of related compounds (e.g. pesticides, drugs, metabolites, etc.) with optimized transitions and collision energies, CAS registry numbers, and Retention Indices (RI). The user can select from hundreds of pre-registered compounds in one of the Smart Database files, or add their own optimized transitions. The user selects the compounds to be analyzed, and Smart MRM builds the MRM or Scan/MRM acquisition method from the Smart Database with the push of a button. Smart MRM Automatic Method Creation Shimadzu s Smart MRM technology creates MRM and Scan/MRM methods by automatically adjusting the analytical dwell times for each transition in a method. For multi-component analyses, with hundreds of compounds and up to 32,768 transitions, adjusting the loop and dwell times for optimum sensitivity can be complex and difficult. Smart MRM User Interface Gas Chromatograph Mass Spectrometer 9

10 GCMSsolution for Quick, Error Free Operation Automatic Adjustment of Compound Retention Time (AART) (Automatic Adjustment of Retention Time) Originally registered method information Customer's instrument C17 C18 C Retention index C17 C18 C19 Identification window The AART function adjusts the retention times of target components based on linear retention indices (LRI) and the retention times of n-alkanes. The AART function easily adjusts acquisition and processing method parameters simultaneously Retention index min 21.5 min (Calculated RT) (Originally registered RT) Automatic adjustment Retention index Analyte 1 n-alkane analysis 2 AART execution 3 Adjustment of retention times Updating compound retention times for low- to high-boiling compounds is simple and accurate. GCMS Browser Program Quantitation Browser The Quantitation Browser allows the user to review multiple data sets in the same window. This permits the user to check chromatograms and quantitation results from multiple samples with minimal switching between windows. Extensive Report Creation Features GCMSsolution software allows the user to design, edit, and customize report formats to meet individual program requirements. Items to be included in reports can be pasted on a blank report page, and size and position modified as needed. Macro functions are also available to display file names or other necessary information. In addition, a generous selection of report templates is available for various applications, so even first-time users can create professional-looking reports easily. 10

11 Smart and Easy Maintenance Easy stop Reduces Maintenance Time Many applications require that the injection port undergoes maintenance is possible without venting the MS so downtime maintenance on a frequent basis. With the GCMS-TQ8040, is minimized. Maintenance start Conventional procedure Injection port cooling Vacuum stopped Maintenanceance Injection port heating Vacuum startup, Attainment of maximum vacuum level, Stabilization, 5 min 10 min 180 min Analysis Easy stop Injection port cooling Maintenance Injection port heating 10 min 15 min Analysis Time savings of 3 hours The Easy stop navigator assists in taking the appropriate steps. User Friendly When changing the ionization method, or performing maintenance on the ion source, the user must access components inside the MS. The GCMS-TQ8040 provides easy, front-opening access to all user-serviceable components without exposing the MS rods or detector, and without requiring additional linear bench space. MSNAVIGATOR provides step-by-step instructions for all user maintenance procedures at point-of-use. Ion Source The line of sight with a flat architecture makes the filament difficult to see. Pursuing a design with ease of maintenance in mind. Line of sight with this instrument MSNAVIGATOR Window Gas Chromatograph Mass Spectrometer 11

12 High-Sensitivity Ion Source The effect of the filament s electric potential on the ion source is reduced by placing more distance between the filament and ion source box. In addition, a shield blocks out radiant heat generated from the filament to ensure the ion source box temperature remains uniform. Since this prevents any active spots within the ion source, it provides higher sensitivity for analysis. (Patent: US ) Shield Temperature Low High : Filament : Electric field : Heat rays Shield beta-endosulfan > > Iprodione > > MRM mass chromatogram (pesticides, 1 ppb) Sensitivity and Repeatability in Single GC/MS Mode The high-efficiency ion source provides the foundation of an ion generation and transmission system, which creates and then delivers ions to the detector, resulting in a GC/MS with the maximum possible sensitivity and repeatability. These features are not realized just for MRM measurements by GC/MS/MS, but also for scan and SIM measurements in single quadrupole modes, even with the most reactive compounds. Q1 with post-rod achieves outstanding ion transfer efficiency UFsweeper provides high ion transfer efficiency %RSD = 1.76 % %RSD = 1.44 % Thiobencarb 5 ppb Left: GCMS-QP2010 Ultra, Right: GCMS-TQ8040 (for RSD determination, n = 5) O S O 93 P O O N O Scan mass spectrum of Fenitrothion Mass spectrum registered in NIST library 12

13 OFF-AXIS Ion Optics Lower detection limits are achieved by OFF-AXIS Ion Optics (Patent Pending). Meta-stable and neutral ions are removed without sacrificing sensitivity. Helium buffer gas is not required in the CID cell. High-Efficiency Collision Cell UFsweeper Shimadzu's proprietary UFsweeper technology achieves high-speed MRM analysis at speeds up to 800 transitions per second. It sweeps residual ions from the collision cell to provide high-efficiency CID and fast ion transport. Rapid ion removal minimizes cross-talk and enables trace analysis (patent pending). SIM MRM > > Analysis of residual pesticides (Isoprothiolane 1 ppb) High-Speed Scanning Control (Advanced Scanning Speed Protocol, ASSP ) ASSP achieves scan speeds of 20,000 u/second. The rod bias voltage is dynamically optimized during ultrahigh-speed data acquisition, thereby minimizing the drop in sensitivity that would otherwise occur above 10,000 u/second. This is necessary for maintaining sensitivity at high scan speeds and acquiring superior mass spectra when performing product ion scans or simultaneous scan and MRM measurement in the Scan/MRM mode. (Patent: US ). Scan/MRM simultaneous analysis is possible by coupling high speed scanning with high speed MRM. Scan 0.05 sec max 20,000 u/sec MRM 0.1 sec Scan (ASSP) Q1 Q3 max 800 MRM/sec Newly Patented Technology (ASSP) Propyzamide Diazinon Black: 1,111u/sec Red : 5,000 u/sec Blue : 10,000u/sec By switching rapidly between scan and MRM modes, data can be acquired using both modes in the same analysis. MRM SIM CID SIM Gas Chromatograph Mass Spectrometer 13

14 Smart Solutions using GCMS-TQ8040 Pesticide Quick-DB Pesticide Quick-DB is a software package that contains Scan/MRM and Scan/SIM acquisition methods and pre-stored calibration curves for over 450 pesticides. The Pesticide Quick-DB uses isotopically labeled pesticide surrogates as internal standards for each compound class to enable rapid, semi- quantitative results. In addition, Scan/MRM simultaneously acquires qualitative mass spectra for confirmation. When used with the Twin Line MS System, detected compounds can also be confirmed on a second, dissimilar column without venting the MS. 1,000, Scan Chromatogram 3.0 MRM Chromatogram Analysis of Pesticides in a Cabbage Extract Using Scan/MRM MRM Mass Chromatogram and Scan Mass Spectra % , > > Quantitation Qualification area ratio The Calibration Curve and the Standard Mass Spectra Registered in Quick-DB (Dichlofenthion)

15 Metabolite Database Biological samples such as blood serum contain large amounts of interfering co-extractants. Due to co-elution of components, some compounds cannot be reliably analyzed using single quadrupole GC-MS. MRM measurements eliminate the effect of interfering background matrices, and enable the targeted compounds to be accurately and reliably identified. The Metabolite Database contains the information of a large number of metabolites included in biological samples. Along with Smart MRM, it supports highly sensitive metabolite measurement. 3-Hydroxyisovaleric acid-2tms ( 100,000) > > ( 1,000) Aconitic acid-3tms ( 10,000) > > ( 100) Kynurenine-3TMS ( 10,000) > > ( 100) Comparison of MRM (Left) and Scan (Right) Mass Chromatogram for Metabolites in Standard Serum Gas Chromatograph Mass Spectrometer 15

16 Environmental Quick-DB Environmental Quick-DB enables rapid semi-quantitative analysis of environmental pollutants by obtaining approximate concentration from the scan data without requiring a preliminary calibration. In addition, Scan/MRM measurement provides semi-quantitative measurement of selected compounds by MRM, with qualitative confirmation of each component detected during the analysis. 100,000, Analysis Results of River water sample Ibuprofen 100, Concentration: ng/l Nonylphenol 1,000, Concentration: ng/l Quantitative Results Using the Database (Scan) PCB #52 (Tetra CB) > > Concentration: ng/l PCB #138 & PCB #129 (Hexa CB) > > Concentration: ng/l Quantitative Results for Targeted Compounds (MRM) 16

17 Forensic Quick-DB The Forensic Quick-DB enables highly accurate detection of over 1,000 compounds that are difficult to detect in the presence of complex biological samples such as blood or urine. The Forensic Quick-DB contains the mass spectra of compounds such as drugs of abuse, psychotropic drugs, and other medicines in blood and urine samples. Diazepam Desmethyldiazepam Flunitrazepam , > >248 10, > > , > > MRM Chromatograms for Whole Blood Sample ,000, % % Mass Spectra of Phenobarbital in Blood Serum Sample (Top) and the Standard Spectra of the compound registered in the Database (Bottom) Gas Chromatograph Mass Spectrometer 17

18 Smart Options Chemical Ionization and Negative Chemical Ionization In addition to commonly-used electron ionization (EI), both chemical ionization (CI) and negative chemical ionization (NCI) are available for the GCMS-TQ8040. The CI mode is a soft ionization technique, used to detect many compounds not possible by EI, and is suited for confirmation of molecular weight. The NCI mode can be used to detect functional groups having a high electron affinity such as halogens. Any of three types of reagent gases (methane, isobutane, or ammonia) can be used. Methyl erucate; C22:1 n-9 EI-GC-MS % PCI-GC-MS/MS % Precursor m/z CE:9V C22:1 n-9 1,000, C20:3 n , > > C20:3 n DI-2010 Direct Sample Inlet Device The DI Probe allows a sample to be introduced directly into the ion source without being passed through a GC column. It is an effective technique for obtaining mass spectra of synthetic compounds that do not chromatograph well. A DI system can be incorporated into a standard GC-MS configuration without making any changes to the GC. It is then possible to switch between conventional GC column chromatography and DI analysis without making any hardware changes. 632 N N N N Sn N N N N Mass spectrum of Sn-phthalocyanine 120 Sn Sn 630 Components that are thermally degradable or difficult to vaporize are not suited to GC analysis. Their mass spectra can be obtained easily using the DI probe. Above is an example of Sn-phthalocyanine spectra obtained using the DI Probe. 116 Sn Advanced Flow Technology Advanced Flow Technology (AFT) provides enhanced separation power and operational efficiency for applications with complex sample matrices. AFT enables reduced analysis times, enhanced chromatographic resolution, and application-specific configurations without compromising key performance features. Separation column Backflush element Restrictor Heart-Cut System Backflush System Detector Splitting System Detector Switching System 18

19 Eco Friendly Eco-Friendly Design for Lower Running Costs in the Laboratory There is increasing public interest in reducing running costs and environmental stress. Reducing power consumption is a common concern in order to reduce both a laboratory's energy cost and CO2 emissions. In addition, helium carrier gas is a non-renewable, valuable natural resource. The GCMS-TQ8040 has eco-friendly features for saving power and carrier gas. Saving Power Consumption with an Ecology mode for Reduced Instrument Running Costs Equipping the instrument with Ecology mode reduces the power consumed in analysis standby mode by 36%, compared with the previous model. For nighttime GC-MS operation, Ecology mode can be set automatically, making it possible to reduce unnecessary power consumption. Ecology mode screen PC Reduction by 36% Reduced Power Consumption in Analysis Standby Mode When Ecology mode is entered, unnecessary power consumption by the GC, MS, and PC is automatically eliminated. The consumption of carrier gas is also automatically reduced. Furthermore, Ecology mode can be entered automatically after continuous analysis, so power and carrier gas can be saved automatically after the completion of nighttime analysis. Power Consumption (W) GC MS Standby in Normal (W) PC GC MS Standby in Ecology mode (W) 760 W 483 W Reduced Annual Power Consumption If Ecology mode is used over one year of operation*, power consumption can be reduced by 26% and CO2 emissions can be reduced by approx. 1.1 tons. *) This is based on 6 hours of use per day for 260 days under our standard analytical conditions. Power Consumption (kwh) Reduction in power consumption by 26% Reduction in CO2 emissions by 1.1 tons Normal mode Ecology mode 7640 kwh 5640 kwh Reduces Power Consumption of Indoor Air Conditioning The ecology mode reduces power consumption during the analysis standby mode. Consequently, it reduces heat output. The ecology mode not only saves instrument energy, it also helps save on the energy required to maintain the room temperature. This product is certified compliant with Shimadzu ECO-label standards. It consumes 36% less power than with the ecology mode switched OFF. Gas Chromatograph Mass Spectrometer 19

20 GCMS-TQ8040 imscope (page 3) may not be sold in your country. Please contact us to check the availability of imscope in your country. Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2014 Printed in Japan ANS

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326 Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326 with Smart Abilities Enhanced Sensitivity Leads to New GC-MS/MS Possibilities The GCMS-TQ8050 features a new highly efficient detector and three

More information

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry PO-CON1619E Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry Pittcon 2016 480-25 Yan Wang, Feifei Tian, Yueqi Li, Guixiang Yang, Taohong

More information

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode PO-CON1610E Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode Pittcon 2016 1110-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry PO-CON111E Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry Pittcon 201 1120-2 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401 Gas Chromatograph Mass Spectrometer No. GCMS-1401 Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS Introduction Development of methods for analysis of drugs of abuse has become a high

More information

Gas Chromatograph Mass Spectrometer

Gas Chromatograph Mass Spectrometer Gas Chromatograph Mass Spectrometer GCMS-TQ84 NX C146-E366 Smart Performance That Boosts Routine Analytical Work Smart Performance Enabling highly sensitive simultaneous analysis of multiple components

More information

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS PO-CONE Research of Polychlorinated Biphenyls (PCBs) Pittcon 0 90-8 Xizhi Wang, Shiheng Luo, Feifei Tian, Jun Fan, Guixiang Yang, Taohong Huang, Shin-ichi Kawano, Yuki Hashi Shimadzu Global COE, Shimadzu

More information

C146-E209. Headspace Samplers. HS-20 Series

C146-E209. Headspace Samplers. HS-20 Series C146-E209 Headspace Samplers HS-20 Series HS-20 Series of Headspace Samplers A Revolutionary System Aimed at Performance and Ease of Use The HS-20 Series is the optimal solution for volatile component

More information

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A Liquid Chromatograph Mass Spectrometer C146-E188A Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the provides higher multiple reaction monitoring (MRM)

More information

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS PO-CON1609E Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS Pittcon 2016 1110-1 Brahm Prakash, William Lipps, Di Wang, Shilpi Chopra, Nicole

More information

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188 Liquid Chromatograph Mass Spectrometer C146-E188 Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the provides higher multiple reaction monitoring (MRM)

More information

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading

More information

Gas Chromatograph Mass Spectrometer

Gas Chromatograph Mass Spectrometer Gas Chromatograph Mass Spectrometer GCMS-TQ8050 NX C146-E363 A3 w420 h297 Ultra-High-Sensitivity Triple Quadrupole GC-MS for Pioneering New Fields Equipped with a new, highly efficient detector and three

More information

WADA Technical Document TD2003IDCR

WADA Technical Document TD2003IDCR IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must

More information

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS PO-CON1408E Quantitative Analysis of Opioids Using a Pittcon 2014 1090-8P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,

More information

Finnigan LCQ Advantage MAX

Finnigan LCQ Advantage MAX www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer

More information

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research PO-CON1655E High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research ASMS 2016 MP-079 Atsuhiko TOYAMA 1, Kumie SATOU 2, Yuki NAKAMURA 2, Ichiro

More information

Protein Sequencer PPSQ-31A / 33A C297-E055B

Protein Sequencer PPSQ-31A / 33A C297-E055B Protein Sequencer PPSQ-31A / 33A C297-E055B Protein Sequencer PPSQ-31A / 33A Achieving Greater Simplicity and Reliability in the Determination of Amino Acid Sequences Analytical Stability Excellent baseline

More information

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest

More information

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,

More information

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404 Gas Chromatograph Mass Spectrometer No. GCMS-1404 Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030 Introduction Contamination of consumer products with pesticides is a growing concern

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

Agilent All Ions MS/MS

Agilent All Ions MS/MS Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build

More information

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

Spectrophotometer for Life Science. BioSpec-nano C101-E112D Spectrophotometer for Life Science BioSpec-nano C11-E112D BioSpec-nano Spectrophotometer for Life Science Drop-and-Start Analysis Automatic Optical Pathlength Setting & Automatic Wiping Low Carryover Achieved

More information

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS PO-CON1646E Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS ASMS 2016 ThP 152 Jackie, Chiew Mei Chong, Hui Xian Crystal Yeong, Cynthia Melanie

More information

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS PO-CON1518E A Method for Simultaneous Analysis of 174 Pesticides Pittcon 2015 2220-12P Feifei Tian, Xizhi Wang, Shiheng Luo, Guixiang Yang, Taohong Huang, Shin-ichi Kawano, Yuki Hashi, Shimadzu Global

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment LCQ Deca XP Plus Improved Ion Optics for Greater Sensitivity and Precision

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller

More information

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,

More information

Pittcon P

Pittcon P PO-CON1701E 76% Increase in Throughput for Determination of Semi-Volatiles Using Narrow-Bore GC Columns and Rapid Data Acquisition with a Highly Sensitive Quadrupole GCMS System Pittcon 2017 1440-14P Brahm

More information

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2 C46-E299 Technical Report Determination of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/Fs) in Foodstuffs and Animal Feed Using a Triple Quadrupole GCMS-TQ8040 System with Smart MRM Transforms

More information

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS TIAFT 204 Toshikazu Minohata, Keiko Kudo 2, Kiyotaka Usui 3, Noriaki Shima 4, Munehiro Katagi 4, Hitoshi

More information

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring High-Throughput Protein Quantitation Using Multiple Reaction Monitoring Application Note Authors Ning Tang, Christine Miller, Joe Roark, Norton Kitagawa and Keith Waddell Agilent Technologies, Inc. Santa

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent

More information

SIFT-MS. technology overview

SIFT-MS. technology overview SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS

More information

ABI 3200 Q TRAP LC/MS/MS System

ABI 3200 Q TRAP LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 ABI 3200 Q TRAP LC/MS/MS System The advantages of an ion trap and the performance of a triple quad. All in one system.

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are

More information

Screening of pesticides in water using SPE on line

Screening of pesticides in water using SPE on line PO-CON E Screening of pesticides in water using SPE on line HPLC 2013 SAMP-38 Stefano Zaza 1, Stefano Maria Lucini 1 1 Shimadzu Corporation, Milano, Italy 1. Introduction Pesticides are widely used in

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

MassHunter TOF/QTOF Users Meeting

MassHunter TOF/QTOF Users Meeting MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks

More information

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography. Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes

More information

TOXICOLOGY & FORENSIC APPLICATIONS

TOXICOLOGY & FORENSIC APPLICATIONS TOXICOLOGY & FORENSIC APPLICATIONS New Developments of Confirmation Instruments Applications in the Poison Control Centre's Thermo Scientific Instrumentation & their integrated solution s specialize in

More information

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded

More information

Powerful Scan Modes of QTRAP System Technology

Powerful Scan Modes of QTRAP System Technology Powerful Scan Modes of QTRAP System Technology Unique Hybrid Triple Quadrupole Linear Ion Trap Technology Provides Powerful Workflows to Answer Complex Questions with No Compromises While there are many

More information

Automated and accurate component detection using reference mass spectra

Automated and accurate component detection using reference mass spectra TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,

More information

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine

More information

MassHunter Software Overview

MassHunter Software Overview MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A

More information

Making Sense of Differences in LCMS Data: Integrated Tools

Making Sense of Differences in LCMS Data: Integrated Tools Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From

More information

WADA Technical Document TD2015IDCR

WADA Technical Document TD2015IDCR MINIMUM CRITERIA FOR CHROMATOGRAPHIC-MASS SPECTROMETRIC CONFIRMATION OF THE IDENTITY OF ANALYTES FOR DOPING CONTROL PURPOSES. The ability of a method to identify an analyte is a function of the entire

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information

Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GC-MS/MS

Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GC-MS/MS POCON1647E Fast and Accurate Analysis of Fluorotelomer Alcohols and Acrylates using Triple Quadrupole GCMS/MS ASMS 2016 ThP 6 Cynthia Melanie Lahey 1, Guo Wei Elgin Ting 2, Hui Xian Crystal Yeong 1, Jackie

More information

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos

More information

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor

More information

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection

More information

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Application Note: 10018 Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS Thermo Fisher Scientific, Austin, TX, USA Key Words Direct Sample Probe Single Quadrupole GC/MS Drugs of Abuse

More information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography PO-CON1618E A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography Pittcon 216 83-12 Qiang Li, Hongyuan Hao, Taohong Huang, Shin-ichi

More information

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation Application Released: January 214 Application Note 522 Characterisation of allergens in cosmetics by GC GC TF MS with Select-eV variable-energy electron ionisation Summary This Application Note shows that

More information

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.

More information

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 1 Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 Review: Technology for Accurate Mass Analysis: TOF LC/MS Mass measurements accurate to several

More information

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue

More information

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS PO-CON1555E Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (215) ASMS 215 ThP 34 Huiyan Yang, Jun Fan, Taohong Huang, Shin-ichi Kawano,

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

GC-CI-MS analysis of TMS derivatives

GC-CI-MS analysis of TMS derivatives GC-CI-MS analysis of TMS derivatives This method describes analysis of TMS derivatives with methane chemical ionisation (CI) rather than the more normal electron impact (EI) ionisation. Methane CI is a

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS PO-CON1529E Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS ASMS 215 WP 77 Miho Kawashima 1, Yuka Fujito 2, Yayoi Ichiki 3, Miho Sakai 4, Takashi

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

Agilent 5977A Series GC/MSD System

Agilent 5977A Series GC/MSD System Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the

More information

costech instruments ECS 4010 Elemental Combustion System CHNS-O

costech instruments ECS 4010 Elemental Combustion System CHNS-O instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:

More information

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis LAAN-A-LM-E124 Application Liquid Chromatography Mass Spectrometry Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis David R. Baker

More information

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0. System Description The VUV PIONA + Analyzer is a VGA-100 Gas Chromatography (GC) detector configured for PIONA compound analysis by the VUV PIONA + method. The VUV PIONA + method uses relatively simple

More information

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

Analyst Software. Automatic Optimization Tutorial

Analyst Software. Automatic Optimization Tutorial This document is provided to customers who have purchased AB Sciex equipment to use in the operation of such AB Sciex equipment. This document is copyright protected and any reproduction of this document

More information

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION A purpose-built collection of the best-inclass components for forensic toxicology Whether you re challenged to present reliable and secure forensic sample

More information

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer) PO-CON9E Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer) ASMS 0 TP7 Sanket Chiplunkar, Prashant Hase, Dheeraj Handique, Ankush Bhone, Durvesh

More information

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis Technical Overview Introduction Metabolomics studies measure the relative abundance of metabolites

More information

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays : Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability

More information

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note Authors Chris Sandy Agilent Technologies Wokingham, Berkshire, UK Jean-Francois Garnier Agilent Technologies

More information

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS Liquid Chromatography Mass Spectrometry SSI-LCMS-096 Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS LCMS-8045 Summary: A short, robust quantitative method for the analysis

More information

Gas Chromatograph Mass Spectrometer GCMS-QP2020 C146-E295A

Gas Chromatograph Mass Spectrometer GCMS-QP2020 C146-E295A Gas Chromatograph Mass Spectrometer GCMS-QP2020 C146-E295A Gas Chromatograph Mass Spectrometer The importance of high-performance analytical instruments for monitoring microscopic quantities of compounds

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Theory and Practical Consequences.

Theory and Practical Consequences. Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.

More information

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward Chemical Analysis PIONA+ Analyzer Characterization of Engine Fuels by Hydrocarbon Group Type think forward Gas Chromatography Bruker 450 PIONA+ Analyzer Bruker s innovative PIONA+ TM Analyzer provides

More information

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Application Note: 3 Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery Yoko Yamagishi, Thermo Fisher Scientific, C-2F 3-9

More information

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis Adam Ladak, Lauren Mullin, and Rhys Jones Waters Corporation, Milford, MA, USA TECHNOLOGY BENEFITS The Xevo TQ-S APGC,

More information

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,

More information

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner

More information

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from

More information