EVALUATION OF EXPERIMENTAL PARAMETER INFLUENCE ON HPLC SEPARATION OF SOME AMINES AND

Size: px
Start display at page:

Download "EVALUATION OF EXPERIMENTAL PARAMETER INFLUENCE ON HPLC SEPARATION OF SOME AMINES AND"

Transcription

1 ACTA UNIVERSITATIS PALACKIANAE OLOMUCENSIS FACULTAS RERUM NATURALIUM 1999 CHEMICA 38 EVALUATION OF EXPERIMENTAL PARAMETER INFLUENCE ON HPLC SEPARATION OF SOME AMINES AND PYRETHROIDS USING TWO b-cyklodextrin COLUMNS Karel Lemr 1, Juraj Ševčík 1, David Friedecký 1, Alena Jonáková 1 and David Jirovský 2 1 Department of Analytical Chemistry, Palacký University, Třída Svobody 8, Olomouc, Czech Republic 2 Laboratory of Bioanalytical Research, Palacký University, Třída Svobody 8, Olomouc, Czech Republic Received May 31, 1999 Abstract Similarly to earlier described procedure the separation of enantiomers of ephedrine, methamphetamine, selegiline, alphametrin and cypermethrin using b-cyclodextrin column Cyclobond I 2000 was optimized. The effect of different parameters (mobile phase composition, flow-rate, temperature and injected amount) on the separation was evaluated. The acquired results were used for comparison of the importance of experimental parameters in optimization of mentioned compound separations on two b-cyclodextrin columns (ChiraDex and Cyclobond). On studied columns differences in cation, organic solvent, injected amount influence on amine separation and differences in ph, temperature, injected amount influence on pyrethroid separation, respectively, were observed. The results show that diversities in the chromatographic behavior of nominally the same columns can be expected. These diversities can be ascribed to the influence of b-cyclodextrin bonding to silica support (the presence of nitrogen atom in ChiraDex stationary phase) and/or other possible varieties in properties of stationary phases (different surface concentration of chiral selector, accessibility of silanol groups etc.). 41

2 Key Words: HPLC, cyclodextrin, enantiomer, amines, pyrethroids Introduction Diverse influence of enantiomers on living organisms has been pointed out many times and for example in pharmacological studies has to be carefully evaluated. The chiral discrimination is all the time interesting phenomenon for chemists. The asymmetric syntheses are important for production of many compounds in pharmaceutical and chemical industry. The production processes (especially the final products) have to be controlled. That is one of the fields of application of analytical methods being able to recognize individual enantiomers. The other ones are research works in the different areas of interest (biochemistry, toxicology, pharmacology etc.). Among other analytical techniques the separation ones offer many possibilities in analyses of optical active compounds. For the enantiomeric separation of some amines, pyrethroids and methamphetamine metabolites we used high performance liquid chromatography (HPLC) 1 3 and capillary electrophoresis 3 5, respectively. In HPLC we employed the chiral stationary phase with b-cyclodextrin bonded to silica. The use of cyclodextrins for chiral discrimination by HPLC has been well known for a longer time 6,7. With mentioned chiral selector we were able to attain good enantiomeric separation of ephedrine, methamphetamine and selegiline in one run 1. We systematically optimized different experimental parameters (ph, organic solvent, salt nature and concentration, flow rate, injected amount and temperature). We stated that each parameter contributes to the final result of course in the different extent for individual studied compounds. The similar procedure was used for the separation of stereoisomers of some pyrethroids 3. We observed for example the change of separation with the change of ph although they are neutral. For amines as well as pyrethroids we used b-cyclodextrin column, similarly for both groups Pirkle type stationary phases were employed In general one type of stationary phase can be used for many compounds differentiating in their structure. On the contrary in HPLC nominally equivalent columns (not only chiral) can give much unlike results. In practical applications we can meet this situation very often for the most widely spread stationary phase, octadecyl chemically bonded to silica. In the presented work we are comparing the influence of different experimental parameters on the chiral separation of ephedrine, methamphetamine, selegiline, alphametrin and cypermethrin (structures see Fig. 1) using two nominally the same stationary phases with b-cyclodextrin bonded to silica. The goal of this work is not to search advantages of one column in comparison to second one. Regarding to limited number of separated compounds it is not possible. We want only to direct attention to the different behavior of used columns what can be interesting for chromatographers working in chiral separation. 42

3 Fig. 1: Structures of studied compounds. Alphamethrin two enatiomers from a cypermethrin stereoisomer mixture, 1 R cis a S and 1 S cis a R. Experimental The chromatographic experiments were performed using a liquid chromatograph Spectra Physics (pump SP 8700, UV/VIS detector SP 8440, all Spectra-Physics, San Jose, CA, USA) equipped with a manual 7125 injector (10 µl loop) (Rheodyne, Cotati, CA, USA) and Chromatography Station for Windows CSW version 1.0 (DataApex, Prague, Czech Republic). UV absorption chromatograms were recorded at 206 and 258 nm, respectively, for amines or at 210 nm in the case of pyrethroids. For the separation of studied compounds two b-cyclodextrin columns were used, ChiraDex 250 x 4 mm I.D., 5 µm, LiChroCart (E. Merck, Darmstadt, F.R. Germany) 1,3 and Cyclobond I 2000, 250 x 4.6 mm I.D., 5 µm (Astec, Whippany, NJ, USA). The temperature of the column was controlled with the precision ±0.1 C using a glass water jacket and a laboratory water thermostat equipped with a freon cooler. Hold-up volumes were determined by at least triplicate injections of water (10 µl) with the detection wavelength 200 nm and mobile phase methanol : water = 40 : 60 (v/v) or mobile phase with higher elution strength. As described previously the mobile phases were prepared by volume by volume mixing of components using HPLC-grade (E. Merck, Darmstadt, F.R. Germany) or UV-grade (Lachema, Brno, Czech Republic) solvents and redistilled water. The other chemicals were of analytical grade 1,3. The hydrochlorides of enantiomers of ephedrine, methamphetamine and selegiline were gift of Farmakon, Olomouc, Czech Republic. The contents of the minor enantiomer in the major one were undetectable using evaluated methods. Cypermethrin and alphamethrin (two enatiomers from a cypermethrin stereoisomer mixture, 1 R cis a S and 1 S cis a R) were supplied by Shell Res. Ltd., Sittingbourne, Kent, U.K. 43

4 Results and discussion The separations of amines and selected pyrethroids were optimized using Cyclobond similarly to earlier described separation performed on ChiraDex 1,3. We followed the influence of mobile phase composition (ph, nature and concentration of added salt, organic solvent), flow-rate, injected amount and temperature. Three examples of separations under optimal conditions are shown on Figs The chromatograms of ephedrine, methamfetamine and selegiline are similar. Sufficient separation of racemates was achieved but also minor enantiomers in the content around 1% can be recognized. As regards pyrethroids the separation of alphamthrin was better on ChiraDex (Fig. 3). Enantiomers are separated to the baseline. Cyclobond allowed to recognize the presence of both enantiomers but to determine one in the excess of the second was not possible. On the contrary better separation of cypermethrin stereoisomers was attained using Cyclobond. Under tested conditions none of the used columns allowed to separate all eight stereoisomers of cypermethrin but using Cyclobond we could better distinguish more peaks in comparison to Chiradex (Fig. 4). We can see that the columns offer different separation of the stereoisomers of single compound, some of its stereoisomers were separated better on ChiraDex (alphamethrin) other on Cyclobond (compare Figs. 3 and 4). Bellow we are comparing the influence of some experimental parameters that showed evident differences in their effect on separation of studied compounds according to the used columns. In the case of amines the optimization on both columns was made with the goal to separate all three enantiomeric pairs in one run. The differences were observed during optimization of cation added to the mobile phase (see Fig. 5 and Tab. 1). The worst results for both columns were attained using Na +. The unsatisfactory situation we observed for ChiraDex where the peaks are very tailing and such separation can not be used for the practical purposes in comparison to Cyclobond. The use of ammonium reduced analysis time as well as tailing on ChiraDex, the change for Cyclobond was not too important. For both columns the best result was achieved using triethylammonium. Especially for ChiraDex the shape of peaks was markedly better. Tab. 1 shows the values of Kaiser s criterion of separation 12 (the explanation of criterion see Fig. 6). Whereas for Cyclobond its change with the change of cation is mild for ChiraDex the criterion shows that it was necessary to make cation optimization to attain required enantiomeric separation. This can be ascribed to the necessity to block the active nonstereoselective centers on stationary phase. Other observed difference between the columns was higher retention of compounds on Cyclobond what allowed to use organic modifier in the mobile phase. Whereas any addition of organic solvent decreases resolution on ChiraDex on Cyclobond could be used to improve resolution especially not between enatiomers but between methamphetamine and selegiline. For Cyclobond in purely water mobile 44

5 Fig. 2: Separation of racemic mixture of ephedrine (EP), methamphetamine (MAP) and selegiline (SEG). ChiraDex: stationary phase: ChiraDex, 5µm; column: LiChroCart 250 x 4 mm I.D.; mobile phase: 500 mmol triethylamine/l water with H 2 SO 4, ph = 3.5; flow-rate: 0.8ml/min; detection: UV absorption at 206 nm; temperature: ambient. Cyclobond: stationary phase: Cyclobond I 2000, 5 µm; column: 250 x 4.6 mm I.D.; mobile phase: 150 mmol triethylamine/l water with H 3 PO 4 (ph = 3.5) : acetonitrile = 99 : 1 (v : v); flow-rate: 1.0 ml/min; detection: UV absorption at 206 nm; temperature: 20 C. 45

6 Fig. 3: Chiral separation of alphamethrin. ChiraDex: mobile phase: 150 mmol triethylamine/l water with H 2 SO 4 (ph = 3.5) : methanol = 45 : 55 (v : v); detection: UV absorption at 210 nm; temperature: 20 C. Cyclobond: mobile phase: 150 mmol triethylamine/l water with H 3 PO 4 (ph = 3.5) : methanol = 50 : 50 (v : v); flow-rate: 0.8 ml/min; detection: UV absorption at 210 nm; temperature: 20 C. Other conditions see Fig. 2. phase the resolution of enantiomers was 1.17 (ephedrine), 1.26 (methamphetamine), 1.30 (selegiline) and the resolution between neighboring peeks of methamphetamine and selegiline was In the mobile phase with 5% of methanol the values of resolution were in the same order 1.18, 1.33, 1.29 and It means that enantiomeric resolution was not worsening and in the same time the resolution between methamphetamine and selegiline was significantly improving. Slightly better enantiomeric resolution was attained using 1% of acetonitrile (instead of methanol), resolutions in the same order were 1.19, 1.37, 1.56, For the enantiomeric separation of studied amines the last discussed parameter is the injected amount. Too high amount of analyte made the separation on both columns impossible. For analyzed amines we observed a higher loss of resolution with the increase of injected amount on Cyclobond. In percentage the loss of resolution 46

7 Fig. 4: Separation of cypermethrin stereoisomers. ChiraDex: flow-rate: 0.6 ml/min; temperature: 10 C. Other conditions see Fig. 3. with the change of racemate concentration in injected solution from 0.05mg/ml to 0.5 mg/ml was close to 40% for Cyclobond and around 10% for ChiraDex, respectively. For the optimization of studied pyrethroid separation we found ph, temperature and injected amount as the parameters with markedly different influence according to the used columns. Pyrethroids are neutral and that is why the influence of ph is not so expected as in the case of amines but the change of pyrethroid separation with the change of ph was observed earlier 3. For alphamethrin using ChiraDex the increase of ph (from 3.5 to 7.5) led to the decrease of the relative retention of its enantiomers from 1.53 to On the contrary on Cyclobond column this relative retention was practically constant (1.09). This can be explained similarly to the influence of cation on amine separation by the participation of other active centers on stationary phase in retention process. For ChiraDex we can expect that for higher ph the contribution of nonstereoselective centers of stationary phase is increasing. 47

8 Fig. 5: Influence of cations on separation of studied amines. ChiraDex: mobile phase: 500 mmol cation/l water with H 2 SO 4, ph = 3.5. Cyclobond: mobile phase: 150 mmol cation/l water with H 3 PO 4 (ph = 3.5) : methanol = 95 : 5 (v : v). Other conditions see Fig

9 Table 1: Influence of cations on value of Kaiser s criterion of separation. &KLUD'H[ &\FORERQG &DWLRQ (3 0$3 6(* (3 0$3 6(* 1D 1+ 7($ ChiraDex: stationary phase: ChiraDex, 5 µm; column: LiChroCart 250 x 4 mm I.D.; mobile phase: 500 mmol cation/l water with H 2 SO 4, ph = 3.5; flow-rate: 0.8ml/min; detection: UV absorption at 206 nm; temperature: ambient. Cyclobond: stationary phase: Cyclobond I 2000, 5 µm; column: 250 x 4.6 mm I.D.; mobile phase: 150 mmol cation/l water with H 3 PO 4 (ph = 3.5) : methanol = 95 : 5 (v : v); flow-rate: 1.0 ml/min; detection: UV absorption at 206 nm; temperature: 20 C. EP ephedrine, MAP methamphetamine, SEG selegiline. Fig. 6: Kaiser s criterion of separation (P = f/g)

10 Table 2. Influence of temperature on relative retention of alphamethrin enantiomers. 7Ã& &KLUD'H[ &\FORERQG ChiraDex: stationary phase: ChiraDex, 5 µm; column: LiChroCart 250 x 4 mm I.D.; mobile phase: 150 mmol triethylamine/l water with H 2 SO 4 (ph = 3.5) : methanol = 45 : 55 (v : v); flow-rate: 0.8ml/min; detection: UV absorption at 210 nm. Cyclobond: stationary phase: Cyclobond I 2000, 5 µm; column: 250 x 4.6 mm I.D.; mobile phase: 150 mmol triethylamine/l water with H 3 PO 4 (ph = 3.5) : methanol = 50 : 50 (v : v); flow-rate: 0.8 ml/min; detection: UV absorption at 210 nm. Relative retention = capacity factor of later eluted enantiomer/capacity factor of earlier eluted enantiomer. Different influence of temperature was observed for alphamethrin (Tab. 2). In the case of ChiraDex its increase led to the worsening of separation but during the change from 25 C to 30 C the selectivity was improving again (it might be the positive influence of change of entropy on separation). For Cyclobond the effect of temperature was negligible. Similarly to amines the next important parameter affecting the chiral discrimination of pyrethroids in the different way was injected amount. The one order higher injection meant for ChiraDex approximately three times and for Cyclobond 1.5 times lower resolution, respectively. The situation is opposite to the case of amine separation and can be probably partially ascribed to the lower starting value of resolution on Cyclobond (0.8 in comparison to 2.4 on ChiraDex) and uncertainty in its calculation. For comparison Kaiser s criterion of separation showed decrease 2.5 times on Cyclobond. Unfortunately this decrease can not be calculated for ChiraDex due to achievement of the limit of this criterion (value 1) for lower injection. Conclusion In the presented work we discussed the experimental parameters that show different importance for the separation on the used columns. Of course the optimization of other parameters is also important to reach good enantiomeric separation but their effect is similar for both columns. In the case of amines we described differences for cations, organic solvent and injected amount, in the case of pyrethroids for ph, temperature and also injected amount. Observed facts can be ascribed to the differences in the stationary phases and column dimension. There can be diversities in surface concentration of chiral selec- 50

11 tor, accessibility of silanol groups, quality of silicagel, in the bonding of b-cyclodextrin to silica support (the presence of nitrogen atom in ChiraDex stationary phase) etc. The found results can not be in any case used for critical comparison of columns regarding to their applicability in chiral separations at least due to limited number of separated compounds. They should point out the problems that can be connected with the transfer of method between two columns with the same chiral selector but from different producers. Acknowledgments We are grateful for support of this work by grant from the Ministry of Education of Czech Republic (grant. No. VS 96021). References 1. Lemr, K., Jirovský, D., Ševčík, J.: J. Liq. Chromatogr. 19, 3173 (1996). 2. Jirovský, D., Lemr, K., Ševčík, J., Smysl, B., Hlaváč, J.: Acta Univ. Palacki. Olomouc., Chemica 35, 85 (1996). 3. Ševčík, J., Lemr, K., Stránský, Z., Večeřa, T., Hlaváč, J.: Chirality 9, 162 (1997). 4. Ševčík, J., Stránský, Z., Ingelse, B. A., Lemr, K.: J. Pharm. Biomed. Anal. 14, 1089 (1996). 5. Ševčík, J., Lemr, K., Smysl, B., Jirovský, D., Hradil, P.: J. Liq. Chromatogr. 21, 2473 (1998). 6. Krstulovic, A. M., (Editor): Chiral Separation by HPLC, Ellis Horwood Limited, Chichester, Pirkle, W. H., Pochapsky, T. C.: Chem. Rev. 89, 347 (1989). 8. Doyle, T. D., Adams, W. M., Fry Jr., F. S., Wainer, I. W.: J. Liq. Chromatogr. 9, 455 (1986). 9. Cayley, G. R., Simpson, B. W.: J. Chromatogr. 356, 123 (1986). 10. Chapman, R. A.: J. Chromatogr. 258, 175 (1983). 11. Lisseter, S. G., Hambling, S. G.: J. Chromatogr. 539, 207 (1991). 12. Schoemakers, P. J.: Optimization of Chromatographic Selectivity A Guide to Method Development, Elsevier, Amsterdam, 1986, p

1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy

1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy Printed in the Republic of Korea "/"-:5*$"- 4$*&/$& 5&$)/0-0(: Vol. 23, No. 1, 97-101, 2010 1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy

More information

KINETICS OF THE CYCLIZATION OF PHENACYL ANTHRANILATE UNDER VARIOUS CONDITIONS

KINETICS OF THE CYCLIZATION OF PHENACYL ANTHRANILATE UNDER VARIOUS CONDITIONS ACTA UNIERSITATIS PALACKIANAE LMUCENSIS FACULTAS RERUM NATURALIUM 999 CHEMICA 38 KINETICS F THE CYCLIZATIN F PHENACYL ANTHRANILATE UNDER ARIUS CNDITINS Hradil Pavel. a, Hlaváč Jan. b, Krejčí Petr. b, Lemr

More information

ON PROBLEMS WITH LIQUID CHROMATOGRAPHIC QUANTIFICATION OF CHIRAL 2-ARYLPROPIONIC ACIDS BY USE OF UV-ABSORPTION-BASED DETECTION

ON PROBLEMS WITH LIQUID CHROMATOGRAPHIC QUANTIFICATION OF CHIRAL 2-ARYLPROPIONIC ACIDS BY USE OF UV-ABSORPTION-BASED DETECTION ACTA CHROMATOGRAPHICA, NO. 17, 2006 ON PROBLEMS WITH LIQUID CHROMATOGRAPHIC QUANTIFICATION OF CHIRAL 2-ARYLPROPIONIC ACIDS BY USE OF UV-ABSORPTION-BASED DETECTION M. Sajewicz and T. Kowalska Institute

More information

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for? Chromatography- Separation of mixtures CHEM 212 What is solvent extraction and what is it commonly used for? How does solvent extraction work? Write the partitioning coefficient for the following reaction:

More information

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Marco Karsten, Bas, Dolman, Giovanni Maio, Frank Steiner, Holger Franz, Frank Arnold and Remco Swart LC Packings,

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).

More information

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010 International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010 RP HPLC ESTIMATION OF EZETIMIBE IN TABLET DOSAGE FORMS NAGARAJU. P *, KRISHNACHAITHANYA. K, CHANDRABABU. D, SRINIVAS.

More information

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets Liquid chromatography was developed by Tswett in early 1900 s and was shown to be a powerful separation

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS John Whelan, Mickey Martin, Raquel Carvallo, Sermin G. Sunol, Aydin K. Sunol* Chemical Engineering

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System

Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infinity Analytical SFC System Determination of Enantiomeric Excess of Metolachlor from hiral Synthesis using the Agilent 126 Infinity Analytical SF System Application Note Specialty hemicals Author Edgar Naegele Agilent Technologies,

More information

LIQUID CHROMATOGRAPHY

LIQUID CHROMATOGRAPHY LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal) Pharmacophore 2011, Vol. 2 (4), 232-238 ISSN 2229 5402 Pharmacophore (An International Research Journal) Available online at http://www.pharmacophorejournal.com/ Original Research Paper SIMULTANEOUS ANALYSIS

More information

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003 HPLC GRATE Chromatography Lab Course Dr. Johannes Ranke Organisation The groups Start at 9:00 am End at 18:00 pm at the latest Friday, 19th we will finish at 2:00 pm Thursday, 11th: Lecture at 08:15 am

More information

3) In CE separation is based on what two properties of the solutes? (3 pts)

3) In CE separation is based on what two properties of the solutes? (3 pts) Final Exam Chem 311 Fall 2002 December 16 Name 1) (3 pts) In GC separation is based on the following two properties of the solutes a) polarity and size b) vapor pressure and molecular weight c) vapor pressure

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase 77-9P Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase J.T. Lee 1 Maria Esther Rodriguez Rosas 2 and Thomas E.

More information

Chromatographic Analysis

Chromatographic Analysis Chromatographic Analysis Distribution of Analytes between Phases An analyte is in equilibrium between the two phases [S 1 ] [S 2 ] (in phase 1) (in phase 2) AS [S2 ] K 2 A S [S1 ] 1 AS, A 1 S Activity

More information

Chiral Columns for enantiomer separation by HPLC

Chiral Columns for enantiomer separation by HPLC Chiral Columns for enantiomer separation by HPLC SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers

More information

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46> High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have

More information

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC) Document A. THIN LAYER CHROMATOGRAPHY (TLC) 1. SCOPE AND FIELD OF APPLICATION The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate

More information

THE STUDY OF CU IONS EXTRACTION WITH BATHOPHENANTHROLINE FROM WATER SOLUTIONS

THE STUDY OF CU IONS EXTRACTION WITH BATHOPHENANTHROLINE FROM WATER SOLUTIONS ACTA UNIVERSITATIS PALACKIANAE OLOMUCENSIS FACULTAS RERUM NATURALIUM 2000 CHEMICA 39 THE STUDY OF CU IONS EXTRACTION WITH BATHOPHENANTHROLINE FROM WATER SOLUTIONS Libor Kvítek, a Dana Sichertová, a David

More information

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS 1. List two advantages of temperature programming in GC. a) Allows separation of solutes with widely varying retention factors in a reasonable

More information

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE Journal of Agricultural, Food and Environmental Sciences UDC 635.546.173/.175]:543.544.5.068.7 Original scientific paper DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE A. Najdenkoska*

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION Pharmacology EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION A. ISIMER N. E. BASCI A. BOZKURT S. O. KAYAALP SUMMARY: In this

More information

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Available online  Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(6):3275-3279 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Development and validation of a matrix solid-phase

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192 15 Sumitomo Chemical Co., Ltd. SUMICHIRAL ------------------------------ 188~192 YMC_GC_Vol12_15_CS4.indd 187 15/09/24 9:49 15 Chiral columns for enantiomer separation by HPLC [SUMICHIRAL OA] *SUMICHIRAL

More information

A validated chiral HPLC method for the enantiomeric purity of alogliptin benzoate

A validated chiral HPLC method for the enantiomeric purity of alogliptin benzoate Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 214, 6(3):234-239 (http://derpharmachemica.com/archive.html) ISS 975-413X CDE (USA): PCHHAX A validated chiral

More information

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were . Introduction.,3 Dichloro Benzoyl Cyanide (,3 DCBC) and survey of analytical methods,3-dcbc substance, is the although advanced intermediate,3-dcbc is a of lamotrigine well-known bulk drug chemical manufactured

More information

Chiral Flash Columns

Chiral Flash Columns 6 -I -I SFC Chiral Columns Chiral Flash/MPLC Columns -I -I Immobilized Crown ether HPLC columns for separation in acidic mobile phase SFC Chiral Columns Chiral Flash Columns CHIRAL FLASH / MPLC Columns

More information

LC-MS compatible Separation of the Fungicide Spiroxamine

LC-MS compatible Separation of the Fungicide Spiroxamine Spiroxamine is a systemic fungicide, which was brought to the market by Bayer CropScience. The substance is a mixture of diastereomers A and B again consisting of 4 enantiomers A1, A2, B1 and B2 (fig.

More information

HPLC Background Chem 250 F 2008 Page 1 of 24

HPLC Background Chem 250 F 2008 Page 1 of 24 HPLC Background Chem 250 F 2008 Page 1 of 24 Outline: General and descriptive aspects of chromatographic retention and separation: phenomenological k, efficiency, selectivity. Quantitative description

More information

Evaluation of Ketone Containing Terpene Compounds using Evaporative Light Scattering Detection

Evaluation of Ketone Containing Terpene Compounds using Evaporative Light Scattering Detection Evaluation of Ketone Containing Terpene Compounds using Evaporative Light Scattering Detection Keywords Introduction Application Note PHA0313 prepels II Detector, Evaporative Light Scattering (ELS), High

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS CH.MOUNIKA*, M.KINNERA Research Article SIR.C.R.REDDY COLLEGE OF PHARMACEUTICAL SCIENCES, ELURU.

More information

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 2015 Content: Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of

More information

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY Chiral Chromatography Chiral - adjective: not superimposable on its mirror image: used to describe a molecule whose arrangement of atoms is such that it

More information

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Luna 2.5 µm C18(2)-HST Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Table of Contents Part 1 Theory 1.1 Abstract...3 1.2 Introduction...3 Part 2 Set Up 2.1

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

Principles of Gas- Chromatography (GC)

Principles of Gas- Chromatography (GC) Principles of Gas- Chromatography (GC) Mohammed N. Sabir January 2017 10-Jan-17 1 GC is a chromatographic technique utilizes gas as the mobile phase which is usually an inert gas (Hydrogen, Helium, Nitrogen

More information

in The International Pharmacopoeia (July 2012) Draft for comment

in The International Pharmacopoeia (July 2012) Draft for comment July 2012 RESTRICTED PROPOSAL FOR REVISION OF HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY in The International Pharmacopoeia (July 2012) Draft for comment Should you have any comments on the attached revision,

More information

Supporting Information

Supporting Information Supporting Information S1 Reversible stereodivergent cycloaddition of racemic helicenes to [60]fullerene: a chiral resolution strategy Rosa M. Girón, Jiangkun Ouyang, Ludovic Favereau, Nicolas Vanthuyne,

More information

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Cations in Power Plant Waters Containing Morpholine Application Note 8 Determination of Trace Cations in Power Plant Waters Containing Morpholine INTRODUCTION Morpholine and ammonium are used as additives in power plant waters. Morpholine acts as a corrosion

More information

Phenobarbital analysis in biological matrix (blood) by high performance liquid chromatography (HPLC)

Phenobarbital analysis in biological matrix (blood) by high performance liquid chromatography (HPLC) Available online at www.ilcpa.pl International Letters of Chemistry, Physics and Astronomy 1 (2014) 31-40 ISSN 2299-3843 Phenobarbital analysis in biological matrix (blood) by high performance liquid chromatography

More information

Chromatography. Gas Chromatography

Chromatography. Gas Chromatography Chromatography Chromatography is essentially the separation of a mixture into its component parts for qualitative and quantitative analysis. The basis of separation is the partitioning of the analyte mixture

More information

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2010, 7(2), 403-408 Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass

More information

637. Thiamethoxam. HPLC method

637. Thiamethoxam. HPLC method 637. Thiamethoxam HPLC method CIPAC Collaborative Trial according to CIPAC Information Sheet N o 293 Dr. Sven Adolph Syngenta Crop Protection Münchwilen AG CH-4333 Münchwilen Switzerland May 212 page 1

More information

Overview. Introduction. NMR hyphenation modes HPLC-SPE-NMR. Advantages and limitations. Examples

Overview. Introduction. NMR hyphenation modes HPLC-SPE-NMR. Advantages and limitations. Examples NMR hyphenation verview Introduction NMR hyphenation modes HPLC-SPE-NMR Advantages and limitations Examples Hyphenated techniques Two or more analytical techniques combined into one integrated and automated

More information

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography Technical Overview 2D-LC Conventional 1D-LC Abstract This Technical Overview presents

More information

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form Research Article ISSN: 0974-6943 M.V.Kumudhavalli et al. / Journal of Pharmacy Research 2014,8(11), Available online through http://jprsolutions.info Reverse Phase High Performance Liquid Chromatography

More information

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications Chapter 27: Gas Chromatography Principles Instrumentation Detectors Columns and Stationary Phases Applications GC-MS Schematic Interface less critical for capillary columns Several types of Mass Specs

More information

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers. Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers. 1 Scope This document describes a chromatographic method which allows the identification as well as the determination of

More information

HPLC Praktikum Skript

HPLC Praktikum Skript HPLC Praktikum Skript Assistants: Gianluca Bartolomeo HCI D330, 3 46 68, bartolomeo@org.chem.ethz.ch Sahar Ghiasikhou HCI E330, 2 29 29, ghiasikhou@org.chem.ethz.ch 1. Introduction In chromatographic techniques,

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 15 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Theory and Practice of High Speed Chromatography for Bioanalysis Stuart Coleman March 20, 2007 "Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007 General Observations about HPLC Separations A good separation is necessary for good bioanalytical quantitation.

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX) Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX) Application Note Forensic Toxicology Authors Bellah. Pule,

More information

High Pressure/Performance Liquid Chromatography (HPLC)

High Pressure/Performance Liquid Chromatography (HPLC) High Pressure/Performance Liquid Chromatography (HPLC) High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the

More information

Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph

Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph J.J. Kirkland Rockland Technologies, Inc., 538 First State Blvd., Newport, Delaware 19804 Abstract Previous

More information

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form Indian Journal of Chemical Technology Vol. 13, May 2006, pp. 242-246 Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form Vinay Saxena a *, Zahid Zaheer b & Mazhar

More information

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Application Note Forensic and Toxicology - Criminalistics Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Using the Agilent 126 Infinity II SFC and Detection by Coupled

More information

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC Technical Procedure for Concentration Determination of 1.0 Purpose This procedure specifies the required elements for the preparation and use of the Agilent 1100/1200 series High Performance Liquid Chromatograph

More information

Voltage-Induced Sample Release from Anion Exchange Supports in Capillary Electrochromatography

Voltage-Induced Sample Release from Anion Exchange Supports in Capillary Electrochromatography 1998 The Japan Society for Analytical Chemistry 571 Voltage-Induced Sample Release from Anion Exchange Supports in Capillary Electrochromatography Shinya KITAGAWA and Takao TSUDA Department of Applied

More information

Enantioseparation of Racemic 1,1'-Binaphthyl-2,2'-diamine by Preparative Liquid Chromatography

Enantioseparation of Racemic 1,1'-Binaphthyl-2,2'-diamine by Preparative Liquid Chromatography 1336 Bull. Korean Chem. Soc. 2004, Vol. 25, No. 9 Jae Jeong Ryoo et al. Enantioseparation of Racemic 1,1'-Binaphthyl-2,2'-diamine by Preparative Liquid Chromatography Jae Jeong Ryoo, * Woo Jeong Kwon,

More information

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide. International Journal of Pharmaceutical Science Invention ISSN (Online): 2319 6718, ISSN (Print): 2319 670X Volume 3 Issue 7 July 2014 PP.08-12 Analytical method development and validation of acetaminophen,

More information

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form International Journal of PharmTech Research CDEN (USA): IJPRIF ISSN : 0974-4304 Vol.4, No.3, pp 1228-1232, July-Sept 2012 Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form Manzoor

More information

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION The GENERAL ASSEMBLY, Considering Article paragraph iv of the agreement establishing the International organisation of vine and wine Upon

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction. LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT Thomas Wenzel, Bates College In-class Problem Set Extraction Problem #1 1. Devise a scheme to be able to isolate organic acids, bases

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Introduction to Pharmaceutical Chemical Analysis

Introduction to Pharmaceutical Chemical Analysis Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The

More information

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (11) 04 QUALIFICATION OF EQUIPMENT ANNEX 1: QUALIFICATION OF HPLC EQUIPMENT Full document title and reference Document type

More information

This method describes the identification of the following prohibited colorants in cosmetic products:

This method describes the identification of the following prohibited colorants in cosmetic products: A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION This method describes the identification of the following prohibited colorants in cosmetic products: Names C I number Pigment Orange 5 12075 Metanil

More information

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application Pharmaceuticals Author Cliff Woodward and Ronald Majors Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation Technical Overview The Agilent InfinityLab D-LC Solution with Active Solvent Modulation Achieving Improved Resolution and Sensitivity for Challenging Combinations of Separation Conditions Author Sonja

More information

Appendix II- Bioanalytical Method Development and Validation

Appendix II- Bioanalytical Method Development and Validation A2. Bioanalytical method development 1. Optimization of chromatographic conditions Method development and optimization of chromatographic parameters is of utmost important for validating a method in biological

More information

CHROMATOGRAPHIC SEPARATION TECHNIQUES SUPERCRITICAL FLUID CHROMATOGRAPHY

CHROMATOGRAPHIC SEPARATION TECHNIQUES SUPERCRITICAL FLUID CHROMATOGRAPHY 2.2.45. Supercritical fluid chromatography EUROPEAN PHARMACOPOEIA 7.0 Control solutions. In addition to the TOC water control, prepare suitable blank solutions or other solutions needed for establishing

More information

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis [ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)

More information

Introduction to Chromatographic Separations

Introduction to Chromatographic Separations Introduction to Chromatographic Separations Analysis of complex samples usually involves previous separation prior to compound determination. Two main separation methods instrumentation are available:

More information

HPLC Workshop 16 June 2009 What does this do? Chromatography Theory Review Several chromatographic techniques Even though each method utilizes different techniques to separate compounds, the principles

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 18 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM IJPSR (2013), Vol. 4, Issue 2 (Research Article) Received on 28 September, 2012; received in revised form, 24 November, 2012; accepted, 23 January, 2013 DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR

More information

Basic Principles for Purification Using Supercritical Fluid Chromatography

Basic Principles for Purification Using Supercritical Fluid Chromatography Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,

More information

Application Note. Authors. Abstract. Pharmaceuticals

Application Note. Authors. Abstract. Pharmaceuticals Enantiomer separation of nonsteroidal anti-inflammatory drugs Using Daicel immobilized polysaccharide-derived chiral columns and the Agilent 1260 Infinity Analytical SFC System Application Note Pharmaceuticals

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis High-Resolution Sampling D-LC for Pharmaceutical Impurity Analysis Detection of Impurities Hidden Under the API Peak at Relevant Levels Application Note Small Molecule Pharmaceuticals and Generics Authors

More information

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine pplication Note Small Molecule Pharmaceuticals, Generics ccurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine igh-resolution sampling D-LC uthors Rongjie Fu and Xinlei

More information

The Nanostream (Pasadena, CA) Veloce system,

The Nanostream (Pasadena, CA) Veloce system, Micro Parallel Liquid Chromatography for High- Throughput Compound Purity Analysis and Early ADMET Profiling Paren Patel,* Sergey Osechinskiy, Jeff Koehler, Li Zhang, Surekha Vajjhala, Chris Philips, and

More information

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2 John P. McCauley, Lakshmi Subbarao, and Rui Chen Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S Superior and faster separations of pyrethroids by UPC 2 allow for higher throughput

More information

Application of the Prodigy ICP as a Multielement-Specific Detector in Chromatography

Application of the Prodigy ICP as a Multielement-Specific Detector in Chromatography Prodigy ICP Application Note: 1048 Application of the Prodigy ICP as a Multielement-Specific Detector in Chromatography Andrew J. Percy and Jürgen Gailer, University of Calgary Peter Brown, Teledyne Leeman

More information

Derivatization of Chiral Compounds with Chiral Reagents and Separation their Isomers by HPLC System

Derivatization of Chiral Compounds with Chiral Reagents and Separation their Isomers by HPLC System www.stmjournals.com Derivatization of Chiral Compounds with Chiral Reagents and Separation their Isomers by HPLC System Abdulrahim M. Khlafulla 1 *, Rajab A. Maga 1, Mohamad F.Elmessmary 2 1 Departmentof

More information

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis Automated Switching Between D-LC and Comprehensive D-LC Analysis The Agilent 90 Infinity D-LC Solution Technical Overview Author Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany Abstract This

More information