One-stop stability. T m & T agg. T m with SYPRO (DSF) Isothermal stability. Thermal recovery. Sizing & polydispersity. Sizing with thermal ramp B 22
|
|
- Barnaby Willis
- 6 years ago
- Views:
Transcription
1
2 One-stop stability Cracking stability using a pile of one-trick, protein-hungry tools is a ton of work. UNcle combines 3 different measurement modes fluorescence, SLS and DLS. So you can crank out all your data in just a few hours, and use way less protein. All the info you ll get makes picking the best formulation or protein construct a piece of cake. T m & T agg T m with SYPRO (DSF) ΔG Isothermal stability Thermal recovery Sizing & polydispersity Sizing with thermal ramp B 22 G 22 k D Viscosity
3 Unleash the UNi Get more data with way less protein. The UNi only needs 9 µl of sample, and you pick how you use it. Run 1 sample in the morning, 48 in the afternoon. Do a DLS read if that s all you need. Or, check DLS, then start a 3-day experiment to monitor real-time stability. Your samples are sealed airtight, so runs can be short or long your call. Full-spectrum Biologics behave differently. With UNcle, you get the whole fluorescence spectrum, so you don t need to know ahead of time how your protein behaves. No need to add dyes either. UNcle picks up aggregation on two wavelengths you ll see both small and large aggregates no matter what SLS 473 Intensity 20 Trp Fluorescence 10 SLS Wavelength (nm)
4 Uncover way more in one shot Trying new formulations or constructs? Get answers for up to 48 samples in under 2 hours. Measure T m and T agg at the same time and know when unfolding leads to aggregation. Add a DLS read before the temp ramp to know if you ve got aggregate trouble right out of the gate. Unfolding (Fluorescence) Amplitude 0.30 DLS Before 0.25 DLS After Hydrodynamic Diameter (nm) T m1 = 65.3 C T m2 = 76.7 C T agg = 73.8 C Aggregation (SLS) Temperature ( C)
5 Isothermal stability UNcle handles DLS or SLS readings for days with no sample evaporation. So set your temp and walk away. Get a headsup on long-term stability. Dynamic light scattering Grab polydispersity, radius, and size distribution with amped sensitivity. Then take the same samples and do a thermal ramp just for grins Formulation A Aggregation (SLS) Formulation B Formulation C Formulation D Intensity (counts/sec) Z Diameter (nm) Time (hours) Temp ( C)
6 B 22 & k D Get B 22 and k D at the same time in the same UNi. Or switch over to G 22 for super high concentrations. Learn on the spot if your protein-formulation combo is good to go or risky for aggregation. Viscosity Use beads to get a snapshot of viscosity without having to wait until later. Figure out how a formulation or concentration tweak changes things with way less protein. Normalized Intensity B 22 = B 22 = B 22 = B 22 = Amplitude Increasing Viscosity Concentration (mg/ml) Hydrodynamic Diameter (nm)
7 Specifications Application Full-spectrum Fluorescence Static Light Scattering (SLS) Dynamic Light Scattering (DLS) T m T agg T m with SYPRO (DSF) ΔG Isothermal stability Thermal recovery Sizing and polydispersity Sizing with thermal ramp B 22 & G 22 k D Viscosity Instrument Minimum sample volume 9 µl, sealed capillaries Simultaneous samples per experiment 48 Sample temperature range C Minimum sample concentration Heating rate Temperature control accuracy 0.05 mg/ml 150 mg/ml IgG (protein-dependent) C/minute ±1 C (<70 C), ±1.5 C (>70 C) Environmental conditions Temperature range: C Humidity: 40 60% relative humidity (non-condensing) Physical Electrical Regulatory compliance Fluorescence and static light scattering Sample precision <2% CV (T m ) SLS resolution Excitation Detection Dynamic light scattering Hydrodynamic diameter range Size accuracy ± 2% Minimum sample concentration Molecular weight range Light source Detection 54 cm W x 50 cm D x 58 cm H, 50 kg Auto switching power supply, voltage V AC, Hz, single phase, fuse rating T6.3AL, 250V, max power 600 W Software has optional 21CFR11 ~15 kda change in mean molecular mass 266 nm and 473 nm laser Fluorescence: CCD spectrometer at full nm spectral range SLS: intensity at 266 nm and 473 nm nm 0.1 mg/ml lysozyme 192 Da 25 MDa 660 nm laser diode Avalanche photodiode module
8 Unchained Labs 6870 Koll Center Pkwy Pleasanton, CA Phone: Toll-free: Unchained Labs. All rights reserved. The Unchained Labs logo, UNcle and the UNcle logo are trademarks and/ or registered trademarks of Unchained Labs. SYPRO is a registered trademark of Molecular Probes, Inc. Rev D
Meet Our Uncle: 12 Stability Applications on One Platform
Tech Note Meet Our Uncle: 12 Stability Applications on One Platform Uncle is an all-in-one stability platform that enables twelve different applications with one instrument. Fluorescence, static light
More informationMeet Stunner: The one-shot protein concentration and sizing combo
TECH NOTE Meet Stunner: The one-shot protein concentration and sizing combo Introduction What if you could get a better read on the quality of your biologics and use less sample at the same time? Stunner
More informationLitesizer Sheet 1. [Home]
Litesizer 500 15.01.15 Sheet 1 [Home] The Product: Litesizer 500 Measurement Modes Particle Size & Distribution Dynamic light scattering (DLS) Zeta Potential Electrophoretic light scattering (ELS) Molecular
More informationParticle Analysis at the Touch of a Button. Litesizer series
Particle Analysis at the Touch of a Button Litesizer series Particle systems can be complex The size and stability of nanoparticles and microparticles are crucial to their function, as well as to their
More informationParticle Analysis at the Touch of a Button. Litesizer series
Particle Analysis at the Touch of a Button Litesizer series Particle systems can be complex The size and stability of nanoparticles and microparticles are crucial to their function, as well as to their
More informationHighly automated protein formulation development: a case study
Application Note Highly automated protein formulation development: a case study Introduction and background Therapeutic proteins can be inherently prone to degradation and instability, and they often pose
More informationUnderstanding the colloidal stability of protein therapeutics using dynamic light scattering
Understanding the colloidal stability of protein therapeutics using dynamic light scattering A Malvern Instruments' Bioscience Development Initiative Executive summary The combination of dynamic light
More informationUse of DLS/Raman to study the thermal unfolding process of lysozyme
Use of DLS/Raman to study the thermal unfolding process of lysozyme A Malvern Instruments' Bioscience Development Initiative Executive summary The combination of dynamic light scattering (DLS) and Raman
More informationIsothermal experiments characterize time-dependent aggregation and unfolding
1 Energy Isothermal experiments characterize time-dependent aggregation and unfolding Technical ote Introduction Kinetic measurements have, for decades, given protein scientists insight into the mechanisms
More informationThe solution for all of your
The solution for all of your nanoparticle sizing and zeta potential needs. DelsaNano Series Blood Banking Capillary Electrophoresis Cell Analysis Centrifugation Genomics Lab Automation Lab Tools Particle
More informationZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight
Particle size Zeta potential Molecular weight ZS90 The ultimate in desktop particle characterization detailed specifications from www.malvern.com/zetasizernano A routine analysis system for particle characterization
More informationAdvanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC
Advanced GPC GPC On Tour, Barcelona, 28 th February 2012 The use of Advanced Detectors in GPC 1 What does Conventional GPC give? Molecular weight averages Relative to the standards used Mw Weight Average
More informationZetasizer Nano ZSP: A Perfect Tool For Life Science Applications
Zetasizer Nano ZSP: A Perfect Tool For Life Science Applications Dr Mike Kaszuba Technical Support Manager E-mail: michael.kaszuba@malvern.com Contents Zetasizer Nano ZSP Software Enhancements Protein
More informationImagent for fnirs and EROS measurements
TECHNICAL NOTE Imagent for fnirs and EROS measurements 1. Brain imaging using Infrared Photons Brain imaging techniques can be broadly classified in two groups. One group includes the techniques that have
More informationThe Plus for your lab!
BioPhotometer plus NEW! analysis system The Plus for your lab! The easy, rapid and reliable BioPhotometer plus analysis system See it clearly! UVette Precision in plastics The patented* 1 UVette is the
More informationThe ultimate in desktop particle characterization
Particle size Zeta potential Molecular weight ZS The ultimate in desktop particle characterization detailed specification from www.malvern.com/zetasizernano The Zetasizer Nano ZS brings you the practicality
More informationStatic and dynamic light scattering. Cy Jeffries EMBL Hamburg
Static and dynamic light scattering. Cy Jeffries EMBL Hamburg Introduction. The electromagnetic spectrum. visible 10-16 10-10 10-8 10-4 10-2 10 4 (l m) g-rays X-rays UV IR micro wave Long radio waves 400
More informationAutomation of biologics formulation stability testing: achieving equivalent results with less manual effort
pplication Note utomation of biologics formulation stability testing: achieving equivalent results with less manual effort Russell urge, Ph.D., Unchained Labs Fanny Reynaud, Pharm.D., LF, écile Jaume,
More informationThe ultimate in desktop particle characterization
Particle size Zeta potential Molecular weight ZS The ultimate in desktop particle characterization detailed specification from www.malvern.com/zetasizernano The Zetasizer Nano ZS brings you the practicality
More informationLab 4. Current, Voltage, and the Circuit Construction Kit
Physics 2020, Spring 2009 Lab 4 Page 1 of 8 Your name: Lab section: M Tu Wed Th F TA name: 8 10 12 2 4 Lab 4. Current, Voltage, and the Circuit Construction Kit The Circuit Construction Kit (CCK) is a
More informationAnalytical methods to characterize aggregates and subvisible particles
Analytical methods to characterize aggregates and subvisible particles Andrea Hawe 9 th P4EU Meeting 30 th November 2015 * MPI * Martinsried 1 Background of company privately held, independent service
More informationUsing High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection
Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection Jennifer Gough 1, Michael Jones 1, Damian Morrison 1, and John Stenson 2
More informationSmall Angle X-Ray Solution Scattering of Biological Macromolecules
Small Angle X-Ray Solution Scattering of Biological Macromolecules Emre Brookes UltraScan Workshop 15 June 2014 Overview Experimental method Sample preparation Experimental data analysis Experimental method
More informationAnalytical Ultracentrifugation Macromolecule Characterization in Solution
Analytical Ultracentrifugation Macromolecule Characterization in Solution AUC TECH OVERVIEW OPTIMA AUC Analytical Ultracentrifugation Beckman Coulter delivered the first AUC sample characterization tool
More informationDEVELOPING A BIOFORMULATION STABILITY PROFILE
DEVELOPING A BIOFORMULATION STABILITY PROFILE Light Scattering and Micro-Capillary Viscometry A Malvern Instruments Bioscience Development Initiative Executive Summary: When used in combination, light
More informationUnderstanding the conformational stability of protein therapeutics using Raman spectroscopy
Understanding the conformational stability of protein therapeutics using Raman spectroscopy A Malvern Instruments' Bioscience Development Initiative Executive summary The combination of Dynamic Light Scattering
More informationChemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES
Chemistry 524--Final Exam--Keiderling May 4, 2011 3:30 -?? pm -- 4286 SES Please answer all questions in the answer book provided. Calculators, rulers, pens and pencils are permitted. No open books or
More informationLS Spectrometer. The DLS and SLS system for sophisticated research
LS Spectrometer The DLS and SLS system for sophisticated research P r o f e s s i o n a l L i g h t S c a t t e r i n g S o l u t i o n s LS INSTRUMENTS THE GLOBAL LEADER IN ADVANCED LIGHT SCATTERING TECHNOLOGIES
More informationSpectrophotometer for Life Science. BioSpec-nano C101-E112D
Spectrophotometer for Life Science BioSpec-nano C11-E112D BioSpec-nano Spectrophotometer for Life Science Drop-and-Start Analysis Automatic Optical Pathlength Setting & Automatic Wiping Low Carryover Achieved
More informationChirascan 6-Cell Peltier Cell Holder: Rapid Optimisation of Buffer Conditions for Stabilising Protein Therapeutics
CHIRASCAN SERIES APPLICATION NOTE Chirascan 6-Cell Peltier Cell Holder: Rapid Optimisation of Buffer Conditions for Stabilising Protein Therapeutics Abstract: The selection of buffer conditions that maximise
More informationNanoparticle Analyzer
Nanoparticle Analyzer Industry's Widest Range and Highest Precision Measurement Instrument for Nano-particle Characterization nano partica SZ-100 A highly advanced analyzer solves the mysteries of the
More informationHCS CellMask Stains. Introduction
HCS CellMask Stains Table 1. Contents and storage information. Material Amount Storage Stability HSC CellMask Blue, Green, Orange, Red, or Deep Red stain (Component A) 250 µg Dimethylsulfoxide (DMSO) (Component
More informationMALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE
MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD Setting the Standard WHAT CAN ADVANCED GPC/SEC DETECTION OFFER YOU? A modern research environment
More informationUsing runt Disposable Cuvettes
Tech Note Guide Table of Contents Ease of Use... 3 Sensitivity... 4 Resolution... 5 Accuracy... 6 Faster Sample Prep... 7 Measuring Molecular Weight... 8 Observing Protein Aggregation... 9 Characterize
More informationHow DLS Works: Interference of Light
Static light scattering vs. Dynamic light scattering Static light scattering measures time-average intensities (mean square fluctuations) molecular weight radius of gyration second virial coefficient Dynamic
More informationSpectroscopy II Introduction: Spectrophotometry and Fluorometry
Introduction: Spectrophotometry and Fluorometry In this experiment you will use the SpectroVis Plus (a small computer controlled Spectrophotometer + Fluorometer) to: Measure the Transmission and Absorbance
More informationONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL
ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL APPLICATIONS Accurate, repeatable, and reliable temperature
More informationExperiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.
Experiment 9 Emission Spectra 9.1 Objectives By the end of this experiment, you will be able to: measure the emission spectrum of a source of light using the digital spectrometer. find the wavelength of
More informationLC-4: Photoelectric Effect
LC-4: Photoelectric Effect Lab Worksheet Name In this lab you investigate the photoelectric effect, one of the experiments whose explanation by Einstein forced scientists into accepting the ideas of quantum
More informationSCI106: Physical Science
SCI106: Physical Science Students are able to gain credit if they have previously completed this course but did not successfully earn credit. For each unit, students take a diagnostic test that assesses
More informationElectronic Supplementary Information
Electronic Supplementary Material (ESI) for Polymer Chemistry. This journal is The Royal Society of Chemistry 2015 Electronic Supplementary Information Tetraphenylethene-containing supramolecular hyperbranched
More informationAmended Specifications as per the Pre Bid meeting held on in Chapter 4
NIPER-G/PUR/GLOBAL/2018/06 Tender Specification for Nano Particle Size (DLS based), Zeta Potential, Molecular weight, Micro rheology measurement A proven complete system should have the measurement facility
More informationL E A. Laser Elemental Analyzer
L E A Laser Elemental Analyzer The Future of handheld analysis The LEA is a hand-held analyzer which uses a low power laser beam to provide instant, on-site, elemental fingerprinting of materials. The
More informationZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY
ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY Performance, Simplicity, Versatility ZETASIZER NANO SERIES Research Performance, Operational Simplicity, Application Versatility The Zetasizer
More informationLaser heating of noble gas droplet sprays: EUV source efficiency considerations
Laser heating of noble gas droplet sprays: EUV source efficiency considerations S.J. McNaught, J. Fan, E. Parra and H.M. Milchberg Institute for Physical Science and Technology University of Maryland College
More informationThe power of multi-detector SEC in the analysis of antibodies
The power of multi-detector SEC in the analysis of antibodies How OMNISEC can measure antibody absolute MW independent of size and structural changes MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT
More informationRuby crystals and the first laser A spectroscopy experiment
Introduction: In this experiment you will be studying a ruby crystal using spectroscopy. Ruby is made from sapphire (Al 2 O 3 ) which has been doped with chromium ions, Cr(3+). There are three sets of
More informationElemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer
Elemental analysis by X-ray f luorescence Sequential benchtop WDXRF spectrometer Elemental analysis is one of the most important fundamental measurements made for industrial quality control and research
More informationVisualize and Measure Nanoparticle Size and Concentration
NTA : Nanoparticle Tracking Analysis Visualize and Measure Nanoparticle Size and Concentration 30 Apr 2015 NanoSight product range LM 10 series NS300 series NS500 series Dec 13 34 www.nanosight.com NanoSight
More informationIntroduction to the calculators in the Zetasizer software
Introduction to the calculators in the Zetasizer software PARTICLE SIZE ZETA POTENTIAL MOLECULAR WEIGHT MOLECULAR SIZE Introduction The calculators are a series of tools in the Zetasizer software that
More informationMeasuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :
Application Report #001 Measuring Lysozyme Monomer at 0.1 mg/ml Concentration Equipment used : ALV-NIBS / HPPS High Sensitivity Version, Lysozyme (MERCK), 0.1 molar Sodium-Acetate buffer (ph 4.25), syringe
More informationCONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR
CONFOCHECK Infrared Protein Analysis Innovation with Integrity FT-IR CONFOCHECK: FT-IR System for Protein Analytics FT-IR Protein Analysis Infrared spectroscopy measures molecular vibrations due to the
More informationnovaa 800 D Atomic Absorption Spectrometer
Technical Data Atomic Absorption Spectrometer Cpt : +27 (0) 21 905 0476 Jhb : +27 (0) 11 794 Dbn : +27 (0) 31 266 2454 1/7 General The is a compact atomic absorption spectrometer with deuterium background
More informationRamanStation 400: a Versatile Platform for SERS Analysis
FIELD APPLICATION REPORT Raman Spectroscopy Author: Dean H. Brown PerkinElmer, Inc. Shelton, CT USA RamanStation 400 RamanStation 400: a Versatile Platform for SERS Analysis Introduction Surface Enhanced
More informationFor the quantitative measurement of PEGylated molecules in plasma, serum and cell culture media
ab138914 Polyethylene Glycol (PEG) ELISA Kit Instructions for Use For the quantitative measurement of PEGylated molecules in plasma, serum and cell culture media This product is for research use only and
More informationab Maleimide Quantification Kit - Colorimetric
ab112140 Maleimide Quantification Kit - Colorimetric Instructions for Use For detecting maleimide in physiology solutions spectrophotometrically. This product is for research use only and is not intended
More informationObserving the Doppler Absorption of Rubidium Using a Tunable Laser Diode System
Observing the Doppler Absorption of Rubidium Using a Tunable Laser Diode System Ryan Prenger 5/5/00 Final Submission Purdue University Physics Department Abstract Using a tunable laser diode, Doppler absorption
More informationCOLOR MAGNITUDE DIAGRAMS
COLOR MAGNITUDE DIAGRAMS What will you learn in this Lab? This lab will introduce you to Color-Magnitude, or Hertzsprung-Russell, Diagrams: one of the most useful diagnostic tools developed in 20 th century
More informationNovel instrumentation to gain insight into the aggregation state of proteins by Taylor Dispersion Analysis: a comparison
Novel instrumentation to gain insight into the aggregation state of proteins by Taylor Dispersion Analysis: a comparison with Dynamic Light Scattering Wendy Louise Hulse *, Rob Forbes, David Goodall, Alex
More informationMalvern Macromolecular Solutions. Innovative Solutions in Material Characterization
Malvern Macromolecular Solutions Innovative Solutions in Material Characterization MALVERN HEADQUARTERS Malvern Instruments is a Spectris company. Innovative Solutions in Material Characterization Particle
More informationMeasurements of protein electrophoretic mobility using the Zetasizer Nano ZSP
Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP Introduction Zetasizer Nano is the market leader in dynamic and electrophoretic light scattering technology for measurements
More informationPhysics Lab #2: Spectroscopy
Physics 10263 Lab #2: Spectroscopy Introduction This lab is meant to serve as an introduction to the science of spectroscopy. In this lab, we ll learn about how emission and absorption works, and we ll
More informationINSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7
INSTRUCTION MANUAL Model 902A Laser Diode Sarcomere Length May 6, 2013, Revision 3 Copyright 2008-2013 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario,
More informationThe Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity
The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High
More informationLABORATORY OF ELEMENTARY BIOPHYSICS
LABORATORY OF ELEMENTARY BIOPHYSICS Experimental exercises for III year of the First cycle studies Field: Applications of physics in biology and medicine Specialization: Molecular Biophysics Fluorescence
More informationprotein biology cell imaging Automated imaging and high-content analysis
protein biology cell imaging Automated imaging and high-content analysis Automated imaging and high-content analysis Thermo Fisher Scientific offers a complete portfolio of imaging platforms, reagents
More informationRC Circuit Lab - Discovery PSI Physics Capacitors and Resistors
1 RC Circuit Lab - Discovery PSI Physics Capacitors and Resistors Name Date Period Purpose The purpose of this lab will be to determine how capacitors behave in R-C circuits. The manner in which capacitors
More informationbase 2 4 The EXPONENT tells you how many times to write the base as a factor. Evaluate the following expressions in standard notation.
EXPONENTIALS Exponential is a number written with an exponent. The rules for exponents make computing with very large or very small numbers easier. Students will come across exponentials in geometric sequences
More informationThe Coulter Principle for Outlier Detection in Highly Concentrated Solutions
The Coulter Principle for Outlier Detection in Highly Concentrated Solutions Particle Characterization Application Note Abstract This application note will benefit chemical and material manufacturers concerned
More informationStorm. the Lightning. Fairy
Storm the Lightning Fairy To Abby and Becky French with lots of love Special thanks to Sue Mongredien If you purchased this book without a cover, you should be aware that this book is stolen property.
More informationLesson 3-2: Solving Linear Systems Algebraically
Yesterday we took our first look at solving a linear system. We learned that a linear system is two or more linear equations taken at the same time. Their solution is the point that all the lines have
More informationnext generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size
Particle size Welcome to the next generation Your sample, expertly processed and prepared Dispersion options 3000 detailed specification sheets from Getting your sample preparation right The US Pharmacopeia
More informationImproving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness
See vibration isolation technology @ www.minusk.com?pdf) Electronic Products and Technology - May 2014 Improving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness vibration
More informationIntroduction to Biological Small Angle Scattering
Introduction to Biological Small Angle Scattering Tom Grant, Ph.D. Staff Scientist BioXFEL Science and Technology Center Hauptman-Woodward Institute Buffalo, New York, USA tgrant@hwi.buffalo.edu SAXS Literature
More informationPHY 221 Lab 9 Work and Energy
PHY 221 Lab 9 Work and Energy Name: Partners: Before coming to lab, please read this packet and do the prelab on page 13 of this handout. Goals: While F = ma may be one of the most important equations
More informationKolligative Eigenschaften der Makromolekülen
Kolligative Eigenschaften der Makromolekülen Kolligative Eigenschaften (colligere = sammeln) Gefrierpunkterniedrigung, Siedepunkterhöhung, Dampfdruckerniedrigung, Osmotischer Druck Kolligative Eigenschaften
More informationLab 3 and 4: Single Photon Source
Lab 3 and 4: Single Photon Source By: Justin Deuro, December 10 th, 2009 Abstract We study methods of single photon emission by exciting single colloidal quantum dot (QD) samples. We prepare the single
More information10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS
10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS Abstract: New components and measurement techniques continue to be introduced for the Zetasizer Nano. New to the system are a Surface
More informationComplete Moisture Analysis
Complete Moisture Analysis Water Activity Instrumentation Dew Point Water Activity & Moisture Analysis Moisture Sorption Isotherms Capacitance Water Activity Accessories PRODUCT CATALOG 2013-2014 DEW POINT
More informationSCI102: Physical Science
SCI102: Physical Science Students explore the relationship between matter and energy by investigating force and motion, the structure of atoms, the structure and properties of matter, chemical reactions,
More informationTL6 Ultra Micro-volume Spectrophotometer
TL6 Ultra Micro-volume Spectrophotometer TL6 is the latest Ultra Micro-volume Spectrophotometer of PERSEE ANALYTICS. It is a small portable instrument for fast analysis of nucleic acid and protein concentrations
More informationDesigning Information Devices and Systems I Summer 2017 D. Aranki, F. Maksimovic, V. Swamy Homework 5
EECS 16A Designing Information Devices and Systems I Summer 2017 D. Aranki, F. Maksimovic, V. Swamy Homework 5 This homework is due on Sunday, July 23, 2017, at 23:59. Self-grades are due on Monday, July
More informationLab Week 4 Module α 3. Polymer Conformation. Lab. Instructor : Francesco Stellacci
3.014 Materials Laboratory Dec. 9 th Dec.14 th, 2004 Lab Week 4 Module α 3 Polymer Conformation Lab. Instructor : Francesco Stellacci OBJECTIVES 9 Review random walk model for polymer chains 9 Introduce
More informationAvailable in white (2,600 K to 8,300 K CCT) Maximum drive current: 400 ma. Wide viewing angle: 120. Electrically neutral thermal path
PRODUCT FAMILY DATA SHEET CLD-28 REV 0 Cree XLamp MX-3 LEDs PRODUCT DESCRIPTION The Cree XLamp MX-3 LED provides the proven lighting-class performance and reliability of Cree XLamp LEDs in a flat-top PLCC
More informationAnalog Circuits Prof. Jayanta Mukherjee Department of Electrical Engineering Indian Institute of Technology - Bombay
Analog Circuits Prof. Jayanta Mukherjee Department of Electrical Engineering Indian Institute of Technology - Bombay Week 05 Module - 05 Tutorial No.4 Welcome everyone my name is Basudev Majumder, I am
More informationThe Intersection of Chemistry and Biology: An Interview with Professor W. E. Moerner
The Intersection of Chemistry and Biology: An Interview with Professor W. E. Moerner Joseph Nicolls Stanford University Professor W.E Moerner earned two B.S. degrees, in Physics and Electrical Engineering,
More informationBECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple
BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple Reliable TOC measurements Stop throwing away your first rep. QbD1200 has virtually eliminated sample-to-sample carryover
More informationSupplementary Materials for
Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2017 Supplementary Materials for Ultrasensitive nanoparticle enhanced laser-induced breakdown spectroscopy
More informationChem 524 Lecture Notes Raman (Section 17) 2013
Chem 524 Lecture Notes Raman (Section 17) 2013 For HTML of 2005 notes, click here XIII. Molecular Light Scattering and Raman Spectroscopy (Read Ch. 16) A. Elastic Scattering o = s - basis for Dynamic Light
More informationFGH40T120SQDNL4. IGBT - Ultra Field Stop. 40 A, 1200 V V CEsat = 1.7 V E off = 1.1 mj
FGHTSQDNL IGBT - Ultra Field Stop This Insulated Gate Bipolar Transistor (IGBT) features a robust and cost effective Ultra Field Stop Trench construction, and provides superior performance in demanding
More informationSetting the Standard for Advanced GPC/SEC Systems
Absolute molecular weight Molecular conformation Molecular size Solution viscosity Viscotek Setting the Standard for s ṙ ṙ Detailed specification sheets from Introducing the system - the leading solution
More informationAdvances in particle concentration measurements
Advances in particle concentration measurements Dr Hanna Jankevics Jones Principal Applications Scientist Company Confidential Outline Advances in particle concentration from Malvern Panalytical Capture
More informationPHY 221 Lab 7 Work and Energy
PHY 221 Lab 7 Work and Energy Name: Partners: Goals: Before coming to lab, please read this packet and do the prelab on page 13 of this handout. Note: originally, Lab 7 was momentum and collisions. The
More informationPH5504A2NA1. Ambient Light Sensor DESCRIPTION FEATURES APPLICATIONS. R08DS0067EJ0100 Rev.1.00 Nov 05, 2012 DISCONTINUED
Ambient Light Sensor DESCRIPTION Data Sheet The is an ambient light sensor with a photo diode and current amplifier. This product has spectral characteristics close to human eye sensitivity and outputs
More information1. Intended use. 2. Introduction. 3. Assay description. 4. Limitations. Instruction For Use Gyrolab Generic PK Kit
Product number P0020499 P0020617 P0020619 Product Name Gyrolab Generic PK Kit Gyrolab Generic PK CD50 Type E Kit Gyrolab Generic PK CD50 Type F Kit 1. Intended use This document describes a protocol to
More informationRaise the limits. Eppendorf Research plus
NEW! NEW! Raise the limits Eppendorf Research plus A completely new experience Eppendorf Research plus Eppendorf sets a new standard in pipetting. The ultra light Eppendorf Research plus pipette meets
More informationConduction and Radiation Prof. C. Balaji Department of Mechanical Engineering Indian Institute of Technology, Madras
Conduction and Radiation Prof. C. Balaji Department of Mechanical Engineering Indian Institute of Technology, Madras Lecture No. # 11 Emissivity Contd So, we will continue the discussion on definition
More informationExpansion of Terms. f (x) = x 2 6x + 9 = (x 3) 2 = 0. x 3 = 0
Expansion of Terms So, let s say we have a factorized equation. Wait, what s a factorized equation? A factorized equation is an equation which has been simplified into brackets (or otherwise) to make analyzing
More informationHIGH PERFORMANCE PARTICLE SIZER THE FIRST SYSTEM TO COMBINE HIGH SENSITIVITY WITH A HIGH CONCENTRATION CAPABILITY
HIGH PERFORMANCE PARTICLE SIZER THE FIRST SYSTEM TO COMBINE HIGH SENSITIVITY WITH A HIGH CONCENTRATION CAPABILITY INTRODUCTION The capability of three systems in one compact unit Compact and versatile
More informationChromTech HPLC System
ChromTech HPLC System High-prssure Gradient System (A) High-pressure pump: 2 pcs UV/VIS detector: 1 piece Gradient control module: 1 unit High-pressure gradient mixer: 1 piece Single channel chromatography
More information