Sample Preparation for Forensic Toxicology and Clinical Research
|
|
- Neal Townsend
- 6 years ago
- Views:
Transcription
1 Sample Preparation for Forensic Toxicology and Clinical Research Part 1: Sample Preparation Options For Forensic Use
2 Agenda E-seminar Series Introduction Challenges for Today s Forensic Toxicology Laboratories Agilent Sample Preparation Technologies An Overview Conclusions and Options 2
3 Agilent Sample Preparation e-seminar Series Part 1: An Introduction to Agilent s sample preparation products Part 2: A practical approach to selecting the right sample preparation product for your needs Part 3: Tips and tools for solving common analytical challenges using sample preparation For Forensic Use 3
4 CHALLENGES FOR TODAY S FORENSIC TOXICOLOGY LABS Evolving analytical approaches Market changes Doing more with less For Forensic Use 4
5 The Ideal Analyzer Analyzer Sample Report 5
6 The Reality: Complex Workflows, With Complicated Challenges Technician and technologist capabilities Complex samples that can vary dramatically from donor to donor, and even from the same donor from day to day Reporting requirements Validation burden Cost and time pressures Consolidation and increased competition For Forensic Use 6
7 Application Challenge: Transitioning Existing Methods from GC-MS to LC-MS LC-MS Potential Advantages Promise of reduced sample prep transition from a complex sample prep protocol to using little to no sample prep Is this because there is no derivatization step in LC-MS? Increased selectivity tandem mass spectrometry or highresolution mass spectrometry Improved sensitivity lower limits of detection, increased injection volumes Speed of analysis or more compounds in one run How Do I Select the Right Sample Prep Product to Exploit My New Instrument s Capabilities? 7
8 Application Challenge: Broader Range of Sample Types and Lower Detection and Quantitation Limits Urine, plasma, serum, and whole blood are common samples Use of hair, oral fluids, meconium, and other tissues is rising Lower limits of quantitation ranging from ng/ml to pg/ml and fg/ml How Do I Select the Right Sample Prep Method to Match My Sample Type? For Forensic Use 8
9 Application Challenge: Emerging Drugs of Abuse and New Compounds to Analyze Spice drugs and bath salts Multi-component screening and confirmation in a single analysis Increase in prescription drug abuse New or continually evolving designer drugs showing up in different geographies How Do I Develop New Methods to Stay On Pace With the Illicit Drug Chemists? For Forensic Use 9
10 Application Challenge: Updating or Creating New Methods on Existing Instrumentation Implementing new testing and assays for existing GC or LC instruments Updating current methods to improve results, reduce costs, increase throughput, optimize effectiveness, etc. Starting point current sample prep methods or find new ones? Method acceptance requirements what needs to be done to get the method ready for use Where Can I Go to Find Out About My Sample Preparation Options? 10
11 AGILENT SAMPLE PREPARATION OPTIONS An overview of available technologies 11
12 Objectives of Sample Preparation Removal of interferences which would affect detection of analyte Removal of interferences that would affect instrument or column lifetime Concentration of an analyte to a detectable concentration Solvent Switching into an analytically more compatible solvent 12
13 Striking the Right Balance in Sample Preparation Just Right Ideal Quality of Results Realistic Effort & Investment 13
14 Agilent Sample Preparation Techniques For Today s Discussion 1. Dilute and Shoot 2. Captiva Filtration Basic particulate removal from ALL kinds of samples Useful when additional step of lipid content removal is needed 3. Chem Elut Solid supported liquid extraction (SLE) Increased productivity using liquid/liquid extraction principle and the concept of automation Ideal for aqueous sample or samples 4. Bond Elut Solid phase extraction (SPE) Ultra-clean sample preparation for analysis when high selectivity and sensitivity are required 14
15 Sample Prep Options: An Overview Direct injection Dilute & Shoot Filtration Liquid/liquid extraction (LLE, SLE) QuEChERS Solid phase extraction (SPE) MIPS and Immunoaffinity Columns Less Selective More Selective For Forensic Use 15
16 Dilute and Shoot Simple sample dilution Advantages Fast and easy High throughput Limitations Interferences are not removed Concentration is reduced Instrument and column contamination Matrix interferences ion suppression or poor peak shapes 16
17 Agilent Captiva Filtration A Straightforward Companion to Dilute-and-Shoot Basic sample prep method for biological samples Can be the first choice of sample prep or secondary step Mechanical filtration for particulate interference removal - Captiva Filter Vial Syringeless filters - Captiva Syringe Filters - Agilent Captiva cartridge and 96-well plate formats - Agilent Captiva ND Non-drip cartridge and 96-well plates Mechanical filtration + extraction by sorbent for lipid removal - Agilent Captiva ND Lipids cartridge and 96-well plates For Forensic Use 17
18 Captiva Filtration Product Recommendation Filtration Needs/Situation Agilent Captiva Product High Throughput Vacuum processing In-well protein precipitation Particulate filtration only Automation Friendly Lipid removal Larger sample size Single cartridge X X X X Single ND cartridge X X can be done X X Single ND Lipids cartridge X X X X X 96-well plate X X X X 96-well ND plate X X X can be done X 96-well ND Lipids plate X X X X X Syringe filter can be done X can be done X For Forensic Use 18
19 Agilent Chem Elut Solid Supported Liquid Extraction (SLE) Extraction mechanism: same as traditional liquid/liquid extraction (LLE) Simple, time-saving process Apply aqueous sample to the solid bed Extract with water-immiscible solvent (MTBE, dichloromethane, ethyl acetate) Analyze extract or evaporate and reconstitute as needed Convert LLE methods to Chem Elut SLE to save time and money, and increase throughput 19
20 Chem Elut SLE - Benefits No emulsions easier extractions No special glassware lower cost per sample Less time, minimal method development faster implementation Reduced technique dependence better ruggedness Increased reproducibility better results Automatable enables batch processing 20
21 Disc Technology: SPEC Disc-Based SPE Pre-Filter SPEC Disc SPEC Solid structure with through pores Higher surface area than packed beds leads to: Higher capacity per bed mass (so smaller bed masses) Smaller elution volumes Suitable for low sample volumes Monolithic-disc, low bed mass Capacity ~10% of bed mass Void volume ~1 3 µl/mg of bed mass 21
22 Bond Elut Solid Phase Extraction Types of SPE - Reversed phase SPE - Cation exchange SPE - Anion exchange SPE - Mixed mode SPE - Specialty SPE - SPEC Disc-based SPE Capabilities - Very selective - Highly clean samples - Wide range of applicability - Automation friendly Condition Load Wash Elute 22
23 Select a Format that Meets Your Needs Tubes 1 ml to 60 ml Straight Barrel (50 mg 10 g) Bond Elut Jr (500 mg 1 g) LRC (Large Reservoir Capacity) ( mg) Mega Bond Elut ml (2 g - 70 g) Multi-Array Well Plates 1 ml, 2 ml 96 Well 1.8 ml VersaPlate OMIX 96 SPEC 1 ml, 2 ml Automation Hamilton TomTEC Gilson ASPEC Gerstel Spark Holland Prospekt 23
24 Bond Elut Packed Bed Phases Non-polar Plexa ENV, LMS, PPL, FOCUS NEXUS C18, C8, C2, C1 C18 variations in carbon load and end-capping EnvirElut CH cyclohexyl CN-E endcapped cyano PH phenyl Anion Exchange SAX quaternary amine PSA primary and secondary amine NH2 aminopropyl DEA diethylaminopropyl Polar PSA - primary and secondary amine NH2 - aminopropyl CN-U unendcapped cyano DEA - diethylaminopropyl Diol Si - silica Mixed mode IEX/NP Plexa PCX Plexa PAX Certify SCX/C8 Certify II SAX/C8 Cation Exchange SCX benzenesulfonic acid PRS propylsulfonic acid CBA carboxylic acid Reversible Covalent PBA phenylboronic acid Specialty Phases AccuCAT Atrazine Etc.. Inorganic, Non-Silica, and Dual-Phase Alumina aluminum oxide Florisil magnesium-silica Carbon Carbon/NH2 24
25 Bond Elut Plexa Polymeric SPE Family Plexa Polymeric SPE Products Plexa reversed phase polymeric SPE Plexa PCX cation exchange mixed mode SPE Plexa PAX anion exchange mixed mode SPE Plexa Polymeric SPE Advantages Rugged methods provide cleaner extracts Simple method development Consistent, fast flow for high throughput 25
26 SUMMARY AND NEXT STEPS Summary of available products Learn more Contact us 26
27 Agilent Sample Preparation Products Bond Elut Solid Phase Extraction Bond Elut SPE Bond Elut Plexa Polymeric SPE SPEC Bond Elut QuEChERS Captiva Filtration Chem Elut SLE Chem Elut SLE Tox Elut SLE Chem Elut Plus SLE Combilute SLE Hydromatrix Captiva Syringe Filters, cartridges, and plates Captiva Non-Drip and ND Lipids cartridges and plates For Forensic Use 27
28 How do Sample Prep Options Compare? Agilent Bond Elut Solid Phase Extraction (SPE) - Very clean, allows for trace analysis, built-in concentration - Potential for greater selectivity (and hence cleanliness) Investment Agilent Chem Elut Solid Supported Liquid Extraction (SLE) - Relatively clean and inexpensive Complexity Agilent Captiva Syringe Filters, Tubes, Plates, and Vials Filtration - Mechanical removal of particulates or functional filtration to remove particulates and lipids Cleanliness Dilute and shoot For Forensic Use 28
29 Learn More E-Seminar Series Part 2: Selecting the Right Sample Preparation Product Agilent Sample Preparation Portfolio Guide Publication Number EN E-Seminar Series Part 3: Applying Sample Preparation to Solve Common Analytical Challenges Agilent Sample Preparation and Analysis for Drug Screening and Confirmation Compendium: www. agilent.com/chem/drugscreeningand Confirmation For Forensic Use 29
30 Contact Us To learn more about the Agilent Sample Preparation portfolio, visit agilent.com/chem/sampleprep To find your local Agilent Representative or Agilent Authorized Distributor, visit agilent.com/chem/contactus U.S. and Canada: Europe: Asia Pacific: India: 30
31 Thank You 31
32 Sample Preparation for Forensic Toxicology and Clinical Research Part 2: Selecting the Right Sample Preparation Product For Forensic Use
33 Agenda E-seminar Series Introduction Agilent Sample Preparation Product Review Selecting the Right Sample Prep A Practical Approach Conclusions and Options 2
34 Agilent Sample Preparation e-seminar Series Part 1: An Introduction to Agilent s sample preparation products Part 2: A practical approach to selecting the right sample preparation product for your needs Part 3: Tips and tools for solving common analytical challenges using sample preparation For Forensic Use 3
35 AGILENT SAMPLE PREPARATION OPTIONS An overview of available technologies 4
36 Objectives of Sample Preparation Removal of interferences which would affect detection of analyte Removal of interferences that would affect instrument or column lifetime Concentration of an analyte to a detectable concentration Solvent Switching into an analytically more compatible solvent For Forensic Use 5
37 Striking the Right Balance in Sample Preparation Just Right Ideal Quality of Results Realistic Effort & Investment 6
38 Agilent Sample Preparation Products Bond Elut Solid Phase Extraction Bond Elut SPE Bond Elut Plexa Polymeric SPE SPEC Bond Elut QuEChERS Captiva Filtration Chem Elut SLE Chem Elut SLE Tox Elut SLE Chem Elut Plus SLE Combilute SLE Hydromatrix Captiva Syringe Filters, cartridges, and plates Captiva Non-Drip and ND Lipids cartridges and plates For Forensic Use 7
39 SELECTING THE RIGHT PRODUCT Considerations and options 8
40 Sample Preparation Considerations We often talk about a triangle but the questions about sample prep and SPE are more complex than this simple model Sorbent Analyte Matrix Other Sample Prep Considerations Analytical goals Published methods Instrument availability Skill and expertise Regulations Sample Size Detection limits Cost per sample Lab setup and supplies investment Automation needs 9
41 Practical Approaches to Selecting a Sample Preparation Method Interferences to Remove Application Type Matrix or Sample Format for Automation C18 Current Product Alternative Journal Article, Application Note, or Book Interactive Selection Guides 10
42 Sample Preparation Selection: Interference Removal Needs Sample Prep Technique Interference Removed More Specific Instrument Separation and Detection Specificity Less Specific Less Specific Sample Preparation Specificity More Specific Dilute & Shoot Filtration Liquid/Liquid Extractions Supported Liquid Extractions (SLE) Dried Matrix Spotting Precipitation filtration QuEChERS Precipitation- Lipid Removal Hybrid' Filtration Lipids No No No Some No No Yes Yes Yes Solid Phase Extraction Oligomeric Surfactants No No No No No No No Yes Yes Particulates No Yes No Some No Yes Yes Yes Yes Pigments No No No Some No No Yes No Yes Polar Organic Acids No No Yes Yes No No Yes No Proteins No No Yes Yes Yes Yes Yes Yes Yes Salts No No Yes Yes No No No No Yes Filtration is suggested with any LC or GC method of sample preparation For Forensic Use 11
43 Sample Preparation Selection: Application Type or Market Area For Forensic Use 12
44 Sample Preparation Selection: Format for Automation or Sample Size 13
45 Sample Preparation Selection: Current Product Alternative Step 1: Locate your current product Step 2: Identify the comparable Agilent product 14
46 Sample Preparation Selection: Journal Article, Application Note, or Book For Forensic Use 15
47 Agilent Product Citation Reference Library Citations for Agilent products demonstrate utility and performance in a wide range of applications, in peerreviewed journals For Forensic Use 16
48 Agilent LC Column and Sample Preparation Navigator Tool For Forensic Use 17
49 Agilent Syringe Filter Selection Tool 18
50 SUMMARY AND NEXT STEPS Selection process overview Learn more Contact us 19
51 Practical Approaches to Selecting a Sample Preparation Method Interferences to Remove Application Type Matrix or Sample Format for Automation C18 Current Product Alternative Journal Article, Application Note, or Book Interactive Selection Guides 20
52 Additional Resources and Options Selecting the right sample preparation method lays the foundation for your analytical success. You can count on Agilent to support your quest to find the products that are just right for your needs: Agilent e-library Agilent technical support and your local Agilent representative Agilent Sample Preparation Product catalog Agilent Sample Preparation Handbook 21
53 Learn More E-Seminar Series Part 1: Sample Preparation Options Agilent Sample Preparation Portfolio Guide Publication Number EN E-Seminar Series Part 3: Applying Sample Preparation to Solve Common Analytical Challenges Agilent Sample Preparation and Analysis for Drug Screening and Confirmation Compendium: www. agilent.com/chem/drugscreeningand Confirmation For Forensic Use 22
54 Contact Us To learn more about the Agilent Sample Preparation portfolio, visit agilent.com/chem/sampleprep To find your local Agilent Representative or Agilent Authorized Distributor, visit agilent.com/chem/contactus U.S. and Canada: Europe: Asia Pacific: India: 23
55 Thank You 24
56 Sample Preparation for Forensic Toxicology and Clinical Research Part 3: Applying Sample Preparation to Solve Common Analytical Challenges For Forensic Use
57 Agenda E-seminar Series Introduction Quick Review of Agilent Sample Preparation Options Tips and Tools for Solving Analytical Challenges Conclusions and Summary 2
58 Agilent Sample Preparation e-seminar Series Part 1: An Introduction to Agilent s sample preparation products Part 2: A practical approach to selecting the right sample preparation product for your needs Part 3: Tips and tools for solving common analytical challenges using sample preparation For Forensic Use 3
59 AGILENT SAMPLE PREPARATION OPTIONS An overview of available technologies 4
60 Striking the Right Balance in Sample Preparation Just Right Ideal Quality of Results Realistic Effort & Investment 5
61 Agilent Sample Preparation Products Bond Elut Solid Phase Extraction Bond Elut SPE Bond Elut Plexa Polymeric SPE SPEC Bond Elut QuEChERS Captiva Filtration Chem Elut SLE Chem Elut SLE Tox Elut SLE Chem Elut Plus SLE Combilute SLE Hydromatrix Captiva Syringe Filters, cartridges, and plates Captiva Non-Drip and ND Lipids cartridges and plates For Forensic Use 6
62 Agilent Sample Preparation Techniques For Today s Discussion 1. Dilute and Shoot 2. Captiva Filtration Basic particulate removal from ALL kinds of samples Useful when additional step of lipid content removal is needed 3. Chem Elut Solid supported liquid extraction (SLE) Increased productivity using liquid/liquid extraction principle and the concept of automation Ideal for aqueous sample or samples 4. Bond Elut Solid phase extraction (SPE) Ultra-clean sample preparation for analysis when high selectivity and sensitivity are required 7
63 How do Sample Prep Options Compare? Agilent Bond Elut Solid Phase Extraction (SPE) - Very clean, allows for trace analysis, built-in concentration - Potential for greater selectivity (and hence cleanliness) Investment Agilent Chem Elut Solid Supported Liquid Extraction (SLE) - Relatively clean and inexpensive Complexity Agilent Captiva Syringe Filters, Tubes, Plates, and Vials Filtration - Mechanical removal of particulates or functional filtration to remove particulates and lipids Cleanliness Dilute and shoot 8
64 COMMON CHALLENGES IN BIOLOGICAL SAMPLE ANALYSIS Biological Sample Analysis 9
65 Agilent Sample Preparation Solutions Matrix Challenges Lab Goals & Needs 10
66 Tandem Mass Spectrometry and The Case of the Disappearing Matrix Selected ion monitoring looking at 100 fg HCB in matrix MRM s better selectivity makes the matrix disappear 11
67 Disappearing Matrix What Can Dirty Samples Do? Interference type Salt/Polar ionics Proteins/ Peptides Lyso-phosphatidylcholines Lipids and other hydrophobics Typical Elution Conditions (C18 column) At or near void with < 20% organic 10 s of column volumes at 40% - 70% organic 10 s of column volumes at 70% - 90% organic 10 s to 100 s of column volumes at > 90% organic Short term effect (single injection) Significant ion-suppression Significant ionsuppression Significant ion-suppression Some ion suppression, however, usually retained on LC column) Long term effect (multiple injections) Unknown Unknown Decreased sensitivity, Increased variability Decreased sensitivity, Increased variability Likely long term causes Ion source contamination Ion source contamination Ion source contamination, Some column build-up Ion source contamination, Column build-up 12
68 Challenge: Instrument Contamination Example 1 Salt build-up in LC-MS ion source from unextracted salts 13
69 Challenge: Instrument Contamination Example 2 Orthogonal ESI Ion Source Condition after 3000x Urine Dilute/shoot Injections Nebulizer/Sprayer Spray Shield/MS Inlet/Capillary For Forensic Use 14
70 Challenge: Instrument Contamination Example 3 GC System Component Contamination with Biological Samples GC Inlet Liner GC Inlet Seal 15
71 Solution: Select an Agilent Sample Preparation Product Based on Interference Removal Particulates Proteins Lipids Surfactants Salts Captiva Filtration Captiva ND Captiva ND Lipids Chem Elut SLE Bond Elut SPE For Forensic Use 16
72 Challenge: Lipids Cause Interference and System Cleanliness Issues R R - R m/z = 184 (+2H) m/z = 184 (+2H) phosphatidylcholine lysophosphatidylcholine Two major lipid interferences that exist during bioanalysis by LC/MS/MS. By soft ionization conditions, these two phospholipids can generate the common fragment, 184 m/z. Removal of ion suppressing lipids can be verified by monitoring m/z transition. For Forensic Use 17
73 Solution: Targeted Lipid Removal Green = ppt only Red = lipid-stripped ppt with Captiva ND Lipids MS Transition For Forensic Use 18
74 Solution: Chem Elut SLE Extraction of Beta-Blockers in Plasma Plasma spiked with beta blockers was diluted by 2% ammonia 1:1. Load 0.3 ml of spiked & diluted plasma to VersaPlate. Apply slight vacuum to initiate flow. When sample is soaked below the top frit stop vacuum. Wait for 5 min for aqueous sample adsorption. Elute with 2 X 0.9 ml of EtOAc. Apply vacuum to have 1 2 drops per sec. After elution increase vacuum for 30 sec. Evaporate and reconstitute in 0.15 ml of 30% MeOH for LC/MS/MS analysis. For Forensic Use 19
75 Beta-Blockers by SLE Chromatography Acebutolol (ISTD) Timolol Nadolol Metoprolol Propranolol Pindolol For Forensic Use 20
76 Solution: Remove Proteins & Lipids Using SPE Exploit the chemistry and physical properties of Agilent Bond Elut Plexa SPE sorbent Polar and non-polar drugs bind in the SDVB hydrophobic end of the pore structure Albumin and proteins of similar size will be excluded Lipids adsorb and do not elute under normal elution conditions For Forensic Use 21
77 Solid Phase Extraction of Buprenorphine and nor- Buprenorphine in Whole Blood SPE using Agilent Bond Elut Plexa PCX polymeric cation exchange buprenorphine at 0.2 ng/ml Buprenorphine and nor-buprenorphine were efficiently extracted from whole blood nor-buprenorphine at 0.2 ng/ml Extraction method was simple and used only 0.5 ml of whole blood Mixed-mode cation exchange SPE ensures removal of matrix and high recoveries of targets Precise, reproducible extraction with low detection limits buprenorphine-d4 (ISTD) at 10 ng/ml nor-buprenorphine-d3 (ISTD) at 10 ng/ml For Forensic Use 22
78 Challenge: Degradation of Sub-2-µm LC Column Performance Over Time 23
79 Solution: Filtration Extends Column Lifetime For Forensic Use 24
80 Challenge: Unexplained Peaks in Sample ESI-Positive Mode Filtered 30% MeOH by Filter W 0.2µm filter IS Filtered 30% MeOH by Filter M PES 0.2µm filter IS Filtered 30% MeOH by Filter P PES 0.2µm filter IS Filtered 30% MeOH by Agilent PES 0.2µm filter IS Unfiltered 30% MeOH IS min 25
81 Solution: Use Certified Clean Filtration Products ESI-Positive Mode Filtered 30% MeOH by Filter W 0.2µm filter IS Filtered 30% MeOH by Filter M PES 0.2µm filter IS Filtered 30% MeOH by Filter P PES 0.2µm filter IS Filtered 30% MeOH by Agilent PES 0.2µm filter IS Unfiltered 30% MeOH IS min 26
82 Challenge: Sample Throughput and Productivity 100s or 1000s of samples a day to be processed Consistency and simplicity to achieve high-quality results with few repeats Limit the operator-to-operator and day-to-day variation (ruggedness) Support for automation for increased throughput and unattended operation 27
83 Solution: Replace Conventional Protein Precipitation with Captiva ND Lipids Centrifugation Protein Precipitation (PPT) Time (min) Captiva ND Lipids Time (min) Add 0.6 ml of MeOH and 0.2 ml of plasma sample to Captiva ND 96-well plate. Centrifuge at 10,000 RPM for 10 min. Transfer supernatant to 2 ml injection vials (if tubes were used) or a new empty 96-well plate for analysis (if plate format was used). Total time required for sample preparation Lipids WILL build up during your sequence. 5 Add 0.6 ml of MeOH and 0.2 ml of plasma sample to Captiva ND 96-well plate. 11 Mix each well with a pipette 5 times and apply vacuum for filtration. 10 Directly transfer injection plate for analysis. Total time required for sample preparation Proteins AND lipids will be removed during your sample preparation. 5 0 For Forensic Use 28
84 Results: Captiva ND Lipids for Beta-blockers in Plasma Acebutolol (ISTD) Timolol Nadolol Atenolol Good chromatography Propranolol Pindolol For Forensic Use 29
85 Challenge: Converting GC-MS Confirmatory Methods to LC-MSMS Confirmation Methods GC-MS methods have long been the gold standard for confirmations Conversion is not typically straightforward not as simple as taking the samples as prepared for GC-MS and putting them onto the LC- MSMS Considerations when using LC-MSMS: Ion ratios Matrix effects including ion suppression and ion enhancement New sample prep and analysis methods Method acceptance 30
86 Solution: Confirmatory Methods and Applications for Major Classes of Drugs of Abuse Application notes describing sample preparation methods using Bond Elut Plexa PCX Polymeric cation exchange SPE with mixed mode capabilities leads to clean extracts Simple methods for high throughput Effective, efficient cleanup with low matrix effects Straightforward method acceptance criteria For Forensic Use 31
87 SUMMARY AND OPTIONS Conclusions Learn More Contact Us 32
88 Conclusions Sample preparation can be a valuable tool to address common analytical challenges Looking at the specific challenge you re having can help match the right Agilent sample preparation product to your issue Agilent offers a range of sample prep products that can be used not only to prepare samples Improve results Increase analytical uptime Maximize productivity and reduce costs Achieve accurate results, right from the start 33
89 Agilent Offers Total Workflow Solutions, from Extraction To Final Report Sample Preparation Separation Detection, Analysis, and Reporting Page 34
90 Learn More E-Seminar Series Part 1: Sample Preparation Options E-Seminar Series Part 2: Selecting the Right Sample Preparation Product Agilent Sample Preparation Portfolio Guide Publication Number EN Agilent Sample Preparation and Analysis for Drug Screening and Confirmation Compendium: www. agilent.com/chem/drugscreeningand Confirmation For Forensic Use 35
91 Contact Us To learn more about the Agilent Sample Preparation portfolio, visit agilent.com/chem/sampleprep To find your local Agilent Representative or Agilent Authorized Distributor, visit agilent.com/chem/contactus U.S. and Canada: Europe: Asia Pacific: India: 36
92 Thank You 37
HPLC Winter Webinars Part 2: Sample Preparation for HPLC
HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do
More informationSample Prep Options for GC users
Sample Prep Options for GC users Tina Chambers Technical Specialist Sample Preparation tina.chambers@agilent.com 949-842-0493 Why Bother? Removal of interferences which would otherwise affect detection
More informationAgilent Products for Solid Phase Extraction. Improve the quality of your sample preparation so you can improve the quality of your analysis.
Agilent Products for Solid Phase Extraction Improve the quality of your sample preparation so you can improve the quality of your analysis. Matrix Analyte Table of Contents The Bond Elut Difference...3
More informationHICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.
HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Extraction - SOLA & HyperSep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationDevelopment of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices
Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices From sample preparation to LC/MS/MS Linda Côté Christophe Deckers Agilent Technologies
More informationAccuracy Starts Here. Agilent Bond Elut Plexa and Polymeric SPE Selection Guide
Accuracy Starts Here Agilent Bond Elut Plexa and Polymeric SPE Selection Guide TABLE OF CONTENTS 1 Solid Phase Extraction 8 Bond Elut Plexa 17 Other Polymeric SPE SOLID PHASE EXTRACTION (SPE) Agilent Bond
More informationEnsure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications
Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Agilent Bond Elut Plexa vs. Waters Oasis Sample Prep Products Reliability is a key parameter in developing rugged,
More informationEVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples
TN143 EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples This Chemistry Data Sheet provides guidelines for the extraction of quaternary
More informationAutomated Sample Preparation. Andrew Duggan, PhD Aman Sharma Shimadzu Scientific Australia
Automated Sample Preparation Andrew Duggan, PhD Aman Sharma Shimadzu Scientific Australia Complete Workflow Solution Extrahera Analyte Extraction Solvent Evaporation Turbovap Analyte analysis LC/MS & GC/MS
More informationSample Preparation. Approaches to Automation for SPE
Sample Preparation Approaches to Automation for SPE i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationUltrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System
Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Authors Mohamed Youssef and Vaughn P. Miller Agilent
More informationSample Preparation. Sample Prep
VARIAN, INC. Sample Preparation Novel chemistries and formats for simpler, easier and faster preparations Consistent high throughput, purity and yield Pioneering technology and global support for more
More information[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples
[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples SIMPLE EASY EFFICIENT DEPENDABLE 2 waters.com/ostro 3 SIMPLE The Ostro Pass-Through Sample Preparation Product provides
More informationSPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver
SPE Simply Efficient! Watchers bond Solid Phase Extraction by ISU Ver. 05-11 Solid Phase Extraction Basic principles of Solid Phase Extraction Solid phase extraction (SPE) is a powerful method for sample
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationtrust Sample Preparation Products
trust Sample Preparation Products Thermo Scientific Chromatography Columns and Consumables 2014-2015 Your sample is precious and you cannot afford failures. Thermo Fisher Scientific has a comprehensive
More information[ Care and Use Manual ]
Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic
More informationPure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.
Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products
More informationSolid Phase Extraction Method Development Tips and Tricks
Solid Phase Extraction Method Development Tips and Tricks Carol Haney Ball, Ph.D. Application Scientist Agilent Technologies, Inc. February 3, 2009 Sources of Error Generated and Time Spent During a Typical
More informationSPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods
How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine
More informationSimplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ]
Simplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ] [ OASIS SAMPLE-EXTRACTION PRODUCTS ] [ ENSURE OPTIMUM RESULTS ] Whether you are working with simple or complex matrices, biological or non-biological
More informationWhat type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation
What type of samples are common? Sample preparation 1 2 Number of samples? Time spent on different operations during LC analyses 3 4 Sources of error Aims Sample has to be representative Sample has to
More informationDevelopment for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009
Advances in Method Development for SPE Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009 Welcome Goals Review the basics of solid-phase extraction (SPE) Discuss the elements
More informationBasics in Solid Phase Extraction (SPE)
Basics in Solid Phase Extraction (SPE) Claudia Thiele, Sigma Aldrich Taufkirchen Euroanalysis 2011 Belgrade Lunch Symposium 13.09.2011 Agenda The Importance of Sample Prep Overview of SPE Technology SPE
More informationGuide to Peptide Quantitation. Agilent clinical research
Guide to Peptide Quantitation Agilent clinical research Peptide Quantitation for the Clinical Research Laboratory Peptide quantitation is rapidly growing in clinical research as scientists are translating
More informationExtraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis
Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation
More informationThermo Scientific Chromatography Columns and Consumables. Trusted solutions. uncompromised analysis
2012-2013 Thermo Scientific Chromatography Columns and Consumables Trusted solutions uncompromised analysis trust Sample Preparation Products Thermo Scientific Chromatography Columns and Consumables 2012-2013
More informationMethods Development Process for Bioanalysis" Stuart Coleman March 22, 2007
Methods Development Process for Bioanalysis" Stuart Coleman March 22, 2007 What is Bioanalysis? In Bioanalysis,, we are measuring the quantity of molecules of interest (analytes) in a complex biological
More informationThermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method
Thermo Scientific HyperSep Dispersive SPE Products Efficient sample preparation and clean-up using the QuEChERS Method The QuEChERS method overcomes the problems associated with time consuming, expensive
More informationDetermination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry
Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Application Note Doping Control Authors Prof. Maria Kristina Parr Freie Universität Berlin Institute
More informationSample Preparation Products General Catalogue. Sample Preparation Products General Catalogue
Sample Preparation Products General Catalogue Sample Preparation Products General Catalogue Solid Phase Cross Reference 3 Objective of Solid Phase Extraction 4 5 Usage of Solid Phase Extraction 6 7 SPE
More informationStrategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin
Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS Lee Goodwin Sample Preparation Chromatography Detection General Strategies Examples New Approaches Summary Outline ABUNDANCE
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationThe Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction
The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction Edouard S. P. Bouvier, Randy E. Meirowitz and Uwe D. Neue Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented
More informationMacrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)
More informationQuantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.
Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction
More informationSPE Columns. Solid Phase Extraction. SPE Columns
SPE Columns Solid Phase Extraction Solid-phase extraction (SPE) is a separation process by which compounds that are dissolved or suspended in a liquid mixture are separated from other compounds in the
More informationBenzoylecgonine in Urine by SAMHSA GC/MS
application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Benzoylecgonine in Urine by SAMHSA GC/MS Introduction The United States Department
More informationFast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma
Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,
More informationYuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB
Use of An Improved Version of C8+SCX Mixed-Mode Solid Phase Extraction Material for Clean Extraction and Recovery of Basic, Zwitterionic, Neutral and Acidic Compounds from Biological Fluids Yuhui Yang,
More informationFigure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)
Supported Liquid Extraction: Automate those Tiresome Bioanalytical Protocols L. Williams, H. Lodder, S. Merriman, A. Howells, S. Jordan, J. Labadie, M. Cleeve, C. Desbrow, R. Calverley and M. Burke 1 Argonaut
More informationCHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.
CHROMATOGRAPHY The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments. THEORY OF CHROMATOGRAPHY: Separation of two sample components in
More informationMaximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System
Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and
More informationFlash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns
Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns Mikael Mahler*, Veronica Thomason, and John Urh Teledyne Isco Inc., P.O. Box 82531, Lincoln
More informationCHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS
Islamic University in Madinah Department of Chemistry CHAPTER - ----- CHROMATOGRAPHIC METHODS OF SEPARATIONS Prepared By Dr. Khalid Ahmad Shadid Chemistry Department Islamic University in Madinah TRADITIONAL
More informationHICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Phase Extraction - Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660 Fax: +44
More informationLC-MS/MS in the Clinical Laboratory. Jo Adaway
LC-MS/MS in the Clinical Laboratory Jo Adaway LC-MS/MS in the clinical laboratory LC-MS/MS is mainly used for quantification of analytes used in the diagnosis and monitoring of disease Semi-quantitative
More informationSupported Liquid Extraction (SLE) Guide and FAQ s. User Guide
Supported Liquid Extraction (SLE) Guide and FAQ s User Guide What is SLE? Supported Liquid Extraction (SLE) is an extraction technique that separates out compounds based on their affinity for one solvent
More informationSPEReference Manual & Users Guide
SPEReference Manual & Users Guide Reference Manual & Users Guide 3 SPE Table of Contents Page No. 1. Objective and Purpose of This Guide 1 2. Solid Phase Extraction Overview 1 3. The Goal of Sample Preparation
More informationA High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma
White Paper A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma Lars Neudert, MSc, Senior Scientist Method Development
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationUltrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System
Ultrafast Analysis of and Metabolite in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Forensic Toxicology Authors Mohamed Youssef and Vaughn P. Miller Agilent
More informationMulti-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation
Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for ample Preparation -Instruction Manual- Table of Contents ection 1 Introduction...1 ection 2 Column Descriptions...2 ection 3 Instructions
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 4,100 116,000 120M Open access books available International authors and editors Downloads Our
More informationEvaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis
Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Keywords: Automated GX-271 GPC Clean-up System, Contaminants,
More informationseparation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a
ONE STEP CLOSER TO A COOK BOOK METHOD FOR DIOXIN ANALYSIS PART 1: THE PROCEDURE Focant JF 1, Shirkhan H 2, Patterson Jr DG 3 1 CART, Organic and Biological Analytical Chemistry, Mass Spectrometry Laboratory,
More informationProtein separation and characterization
Address:800 S Wineville Avenue, Ontario, CA 91761,USA Website:www.aladdin-e.com Email USA: tech@aladdin-e.com Email EU: eutech@aladdin-e.com Email Asia Pacific: cntech@aladdin-e.com Protein separation
More informationBEKOlut - YOUR PARTNER FOR SMART SPE SOLUTIONS
BEKOlut - YOUR PARTNER FOR SMART SPE SOLUTIONS FEEL FREE TO USE QUALITY TABLE OF CONTENTS BEKOlut SPE robust und reproducible BEKOlut GmbH & Co. KG Our values The key to reproducible Solid-phase Extraction
More informationSAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120
SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 Application Note Forensic Toxicology Authors Irina ioumaeva, John M. Hughes Agilent
More informationChemistry Instrumental Analysis Lecture 28. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.
More informationOpiates in Urine by SAMHSA GC/MS
application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Opiates in Urine by SAMHSA GC/MS Introduction The United States Department of Health
More informationAnalytical Instrumentation
Gas Chromatography and Mass Spectrophotometry Environmental, food safety, toxicology, and forensic gas chromatography applications are more demanding than ever. Our portfolio of GC, GC- MS, GC-MS/MS and
More informationHPLC Column Material - Bulk Ware
HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide
More informationAnalytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1
More informationApplication of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples
Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples Craig R. Aurand 1, Robert Shirey 1, Leonard Sidisky 1 Janusz Pawliszyn 2, and Yong Chen
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationApplication Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors
Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food
More informationImproved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18
Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18 Column Xin Zhang, Jonathan P. Danaceau, and Erin E. Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Semi-validated
More informationAgilent SampliQ Products for SPE. Improve the quality of your SPE so you can improve the quality of your analysis.
Agilent SampliQ Products for SPE Improve the quality of your SPE so you can improve the quality of your analysis. Table of Contents Introduction to SampliQ...3 Choosing your product...4 SampliQ Phases...5
More informationFractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)
Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX) Application Note Forensic Toxicology Authors Bellah. Pule,
More informationMixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma
Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Ken Meadows, Thermo Fisher Scientific, Runcorn, UK Application Note 20789 Key Words
More informationIntroduction to Pharmaceutical Chemical Analysis
Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationLC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120
LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 10 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract
More informationPlasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe
More informationHigh Performance Liquid Chromatography
STANDARDBASE techniques: High Performance Liquid Chromatography Drenthe College, The Netherlands 1. Introduction HPLC. High Performance Liquid Chromatography High Performance Liquid Chromatography (HPLC)
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationWALKUP LC/MS FOR PHARMACEUTICAL R&D
Pharmaceutical Workflow Solutions WALKUP LC/MS FOR PHARMACEUTICAL R&D Chemists, Peptide/Protein Chemists, Biologists, and Beyond MASSHUNTER WALKUP A Single User Interface for Robust and Reliable LC/MS
More informationPerfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM
Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),
More informationEVOLUTE EXPRESS SPE Products. Load-Wash-Elute SPE Products
EVOLUTE SPE Products Products 19 EVOLUTE Columns and Plates EVOLUTE represents a leap forward in high throughput solid phase extraction. The EVOLUTE range of SPE columns and 96-well plates combine powerful
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationExtraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis
Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range
More informationLC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120
LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract
More informationAbstract. Experimental Sample Preparation
Determination of Benzoylecgonine in Human Urine Using Automated, In-Line, ITSP Solid Phase Extraction and Liquid Chromatography Mass Spectrometric Detection Thurman L. Allsup 1, Kenneth C. Lewis 1 and
More informationFluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor luorophenyl Column With Raptor
More informationBulletin 910. Guide to Solid Phase Extraction. Introduction 1
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628 814-359-3441 Fax 800-447-3044 814-359-3044 email: supelco@sial.com sigma-aldrich.com/supelco Guide to Solid Phase Extraction
More informationOUTLINE 18/08/2011 NEW DEVELOPMENTS IN LC/MS/MS FRONT-END AUTOMATION. Expanding role of tandem mass spectrometry in the clinical laboratory
OUTLINE NEW DEVELOPMENTS IN LC/MS/MS FRONT-END AUTOMATION Brett McWhinney, Supervising Scientist, HPLC/Mass Spectrometry Section, Pathology Central, Pathology Queensland 11 th August 2011 AIMS NZIMLS South
More informationLecture 15: Introduction to mass spectrometry-i
Lecture 15: Introduction to mass spectrometry-i Mass spectrometry (MS) is an analytical technique that measures the mass/charge ratio of charged particles in vacuum. Mass spectrometry can determine masse/charge
More informationChemical Analysis Problem
Chemical Analysis Problem Hair analysis is frequently used for the long-term monitoring of drug and alcohol users. You are working at a forensics laboratory and have been given the task of developing a
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationTECHNETIUM-99 IN WATER
Analytical Procedure TECHNETIUM-99 IN WATER (WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all
More information10/18/2006. Biotage A Life Science Technology Company
10/18/2006 Biotage A Life Science Technology Company About Biotage Headquartered in Uppsala, Sweden Three Centers of Excellence Uppsala, Sweden Research & Development Charlottesville VA, U.S.A. Instrument
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationNICKEL-63/59 IN WATER
Analytical Procedure NICKEL-63/59 IN WATER 1. SCOPE 1.1. This is a method for the separation and measurement of nickel- 63/59 in water samples. 1.2. This method does not address all aspects of safety,
More informationApplication Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India
Analysis of fumonisin, FB1 and FB2 mycotoxins in corn food and feed samples using the Agilent 1120 Compact LC System coupled to the Agilent 6140 Single Quadrupole LC/MS System Application Note Food Safety
More informationThe end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry
The end of mass-speculation Pre-cleaned and certified vials for mass spectrometry Bonded, ultra-pure closures LC/MS and GC/MS Manufacturing the Ultimate Vial for Mass Spectrometry More than a quarter century
More informationIncubation time too short Incubate samples overnight at 4 C or follow the manufacturer guidelines.
Poor standard curve Improper standard solution Standard improperly reconstituted Standard degraded Curve doesn't fit scale Pipetting error Confirm dilutions are made correctly. Briefly spin vial before
More information