The Challenge: Sepax SEC C-line columns!
|
|
- Claire Ross
- 6 years ago
- Views:
Transcription
1 The Challenge: Are you working with a sample that shows a tendency to stick to traditional size exclusion resins with delayed elution time, low recovery, varying HMWS, or excessive tailing? Sepax SEC C-line columns! Some comparison examples on the two different surface chemistries on size exclusion separation ADC Fusion Protein mpeg-peptide Hydrophobic Peptide MAb Glycoprotein PEGlylated peptide Membrane Protein
2 SEC phases Difference in Phase Structures Tough samples: ADC, Derivatized MAb, Pegylated Protein, Membrane Protein, Super sticky protein, and etc. Characteristics Zenix, SRT Zenix-C, SRT-C Particle size 3 mm, 5 mm 3 mm, 5 mm Zenix 8, 1, 15, 3, Zenix-C 8,1, 15, 3 Pore size (Å) SRT 1, 15, 3, 5, 1 & 2 SRT-C 1, 15, 3, 5, 1 & 2 Surface structure Chemically bonded stand-up monolayer Chemically bonded lay-down monlayer Applications Versatile for mabs, proteins, peptides, oligonucleotides, virus, VLPs, and watersoluble polymers Ideal for hydrophobic samples such as insulin or ADC, hydrophobic mab, pegylated peptides and proteins SRT SEC-1 (1 mm) is the latest addition for semi-prep and prep scale separation. SRT SEC-1 and 2 are suitable for very large biomolecule separation. 2
3 Herceptin Analysis on Zenix TM SEC-3 ( 783 ) Column: Zenix TM SEC-3, ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 15 mm phosphate buffer Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin 2.34 mg/ml Rs=
4 Herceptin Lysine ADC Analysis on SEC-3 ( 783 ) Column: Zenix TM SEC-3, Zenix TM - C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 15 mm phosphate buffer Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin-lysine conjugate 2.5 mg/ml Zenix TM - C SEC-3 Zenix TM SEC
5 Herceptin-Lysine Drug Conjugate Analysis Zenix-C SEC-3 vs. Tosoh TSKgel G3SW XL Column: Zenix - C SEC-3 (3 µm, 3 Å, 7.8 x 3 mm), Tosoh TSKgel G3SW XL (5 µm, 25 Å, 7.8 x 3 mm) Mobile phase: 15 mm phosphate buffer, ph 7.; Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin-lysine drug conjugate 2.5 mg/ml 1 Rs=1.45, total area Rs=1.18, Total area Zenix-C Tosoh TSKgel G3SW XL Disclaimer: TSKgel and Tosoh Bioscience are registered trademarks of Tosoh Corporation; Comparative separations may not be representative of all applications.
6 Herceptin Lysine ADC Analysis on SEC-3 ( 783 ) Column: Zenix TM - C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: as indicated Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin lysine conjugate 2.5 mg/ml mm phosphate, ph 7. Rs=1.41, tailing= Buffer 1: 1% IPA = 95%:5% Rs=1.5, tailing= Buffer 1:1% IPA = 9%:1% Rs=1.45, tailing=
7 Herceptin Cysteine ADC (cleavable linker) Analysis on SEC-3 ( 783 ) Column: Zenix TM SEC-3, Zenix TM - C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 15 mm phosphate buffer Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin Cysteine ADC with cleavable linker 2.5 mg/ml Zenix TM - C SEC-3 Zenix TM SEC
8 Herceptin Cysteine ADC Analysis on SEC-3 ( 783 ) Column: Zenix TM - C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: as indicated Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 1 µl; Samples: Herceptin Cysteine ADC with cleavable linker 2.5 mg/ml mm phosphate, ph Buffer 1: 1% IPA = 95%:5% 3. Buffer 1:1% IPA = 9%:1%
9 Antibody drug conjugate Analysis on SEC-3 ( 783 ) Phase comparison Column: Zenix TM SEC-3, Zenix TM -C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 15 mm phosphate buffer Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 2 µl; Samples: 1.68 mg/ml ADC Zenix-C Zenix Zenix-C SEC-3 imizes the secondary interaction between ADC and resin. 9
10 Antibody drug conjugate Analysis on Zenix TM -C SEC-3 ( 783 ) Column: Zenix TM -C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: As indicated Flow rate: 1 ml/; Detector: UV 28 nm; Column temperature: 25 Injection volume: 2 µl; Samples: 1.68 mg/ml ADC A. 15 mm phosphate buffer, ph 7. B. A +.2 M arginine, ph 7. C. A : Acetonitrile = 9:1 (v/v) D. 5 mm Phosphate buffer +.2 M NaClO 4, ph 7. Buffer R Tailing % agg % monomer A B C D A B 1 C D With 1% acetonitrile and 2 mm NaClO 4, total protein recovery, resolution and tailing factor of monomer peak are improved. 1
11 MAb F Analysis on Zenix-3 and Zenix-C 3 Column: Zenix-3, Zenix-C 3 ( 3 µm, 3 Å, 7.8 x 3 mm ) Mobile phase: 15 mm Sodium Phosphate, ph 7., Flow rate: 1. ml/ Detector: UV 28 nm, Column temperature: 25, Pressure: 74 bar Injection volume: 1 µl, Sample: 1.23 mg/ml MAb F in 1 mm sodium succinate, ph MAb MW 145kD pi = 8.4 Zenix-3 Zenix-C C-line SEC outperforms
12 Fusion Protein Analysis on SEC-3 ( 783 ) Column: Zenix TM SEC-3, Zenix TM -C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 15 mm Phosphate buffer ( ph 7. ) + 2 mm NaCl; Flow rate:.5 ml/; Detector: UV 214 nm; Column temperature: 25 ; Injection volume: 1 µl; Samples: 1 mg/ml fusion protein, MW 17 kd, pi Blue: Zenix TM SEC-3 Red: Zenix TM -C SEC C-line SEC imizes the secondary interaction. 12
13 Fusion Protein Analysis on Zenix TM -C SEC-3 ( 783 ) Mobile phase effect Column: Zenix TM -C SEC-3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: as indication Flow rate:.5 ml/; Detector: UV 214 nm; Column temperature: 25 ; Injection volume: 1 µl; Samples: 1 mg/ml fusion protein, MW 17 kd, pi mm Phosphate buffer, ph mm NaCl mm phosphate, ph 7. +1% ACN mm phosphate, ph % retention time offset for presentation purpose 13
14 2 Glycoprotein I analysis on Zenix-3 and Zenix-C 3 Column: 7.8x3 mm, Mobile phase: 15 mm Sodium Phosphate Buffer ph 7., Flow rate: 1. ml/, Sample: 2 Glycoprotein I (.5 mg/ml in 1M glycine, 75 mm NaCl, ph 7.4), Injection volume: 2 ml, Detection: UV 28 nm Zenix SEC-3 Zenix-C SEC Zenix-C gives a better separation
15 mpeg-peptide (2 kd PEG + 4 kd peptide) Mobile phase is 15 mm phosphate buffer, ph 7.. Flow rate is at 1. ml/ with UV214 nm detection. mpeg-peptide concentration is 6 mg/ml, injection volume is 1µL. Traditional SEC Zenix-C SEC mpeg - peptide 2 1 2xmPEG - peptide
16 Pegylated Exenatide on Zenix-3 and Zenix-C 3 Column: Zenix-3 and Zenix-C 3 ( 3 µm, 3 Å, 7.8 x 3 mm) Mobile phase: 5 mm CH 3 COONH 4 : ACN = 9 : 1 ( v/v ), Flow rate:.5 ml/ Detector: UV 214 nm, Column temperature: 25, Injection volume: 15 µl Pressure: 42 bar, Sample: 3.3 mg/ml PEG-Exanatide in water (PEG 23 kd) Tailing Zenix-C 3 Zenix 3 Tailing
17 Angiotensin I Acetate separation on Zenix-8 and Zenix-C 8 Column: Zenix SEC-8 7.8x3 mm, Flow rate: 1mL/, Detection: UV 214 and 28 nm, Mobile phase: 15 mm Sodium Phosphate Buffer ph 7., Injection Volume: 5 µl 35 Zenix SEC-8 Zenix-C SEC
18 Membrane protein Aqpz separation on Zenix-3 and Zenix-C 3 Column: SRT-C 3, 7.8x3, Mobile phase: 2 mm TrisHCl, ph 7., 19 mm NaCl, 1 mm KCl, 4 mm Octyl glucoside, Detection: 28nm, Flow: 1 ml/, Injection: 2 ml of 6 mg/ml Aqpz is a 23kD protein, BOG is nonionic Zenix-3 1 SRT-C SRT-C 3 gives the best separation with less secondary interaction, baseline separation with the high molecular weight proteins.
19 Bacterial K Channel (16 kd homotetramer) in.261% DDM Column dimension: 4.6 x 3 mm, Mobile phase: 2 mm Tris ph 7.5, 2 mm NaCl,.261% DDM, Detection: 28 nm, Flow rate:.35 ml/, AKTA FPLC system SRT -C SEC has the best recovery for Bacterial K Channel in the presence of detergents SRT -C SEC Traditional SEC Acknowledgement: Sung Lee at Scripps.
NOTES. Fusion Protein Separation. Highlighted FACTS:
Fusion Protein Separation NOTES Highlighted FACTS: Fusion proteins are structural hybrids that contain two different proteins, which retain the functional properties from the original proteins. Zenix and
More informationSepax SRT -C, Zenix -C SEC Phases
Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based
More informationBSA pegylation PG Journal of chromatographic A, 1147 (2007)
BSA pegylation BSA 5mg/mL, pi= 4.7, Sigma A796, 65-7% free sulfyhydryl, cysteine 34 of BSA is not paired with another cysteine in the protein structure 1. PEG 1kD, kd, 3 kd 1mg/mL PEG:BSA=1.2:1 (molar
More informationSRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography
Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion
More informationNOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution
Having trouble applying size exclusion chromatography to peptides under 1, Da? What if there was a size exclusion column specifically designed for small protein and peptide separations? Sepax Zenix SEC-8
More informationAdvantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis
Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis Comparing Columns from Different Vendors to Improve Data Quality Technical Overview Introduction Size exclusion chromatography
More informationImpact of Pore Exclusion on Reversed-Phase HPLC Column Performance
Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance Richard A. Henry, Technical Consultant, 983 Greenbriar Drive, State College, PA 16801 (hyperlc@comcast.net) Stephanie Schuster, AMT, Inc.,
More informationClearing the Confusion: GPC, SEC, GFC What, When, Why, and How?
Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Jean Lane Applications Engineer LC Columns & Consumables Technical Support January 19, 2017 What we will cover What - Clarification of the
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationImprove HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size
Improve HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size Richard A. Henry, Consultant 983 Greenbriar Drive State College, PA 16801 HyperLC@comcast.net Stephanie A. Schuster, Sr. Chemist
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationEffects of Secondary Interactions in Size Exclusion Chromatography
52 Effects of Secondary Interactions in Size Exclusion Chromatography Liz Bevan, Agilent Technologies, Church Stretton, UK Size-based separations are a form of chromatography which, unlike many other chromatographic
More informationNo.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page
No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More informationTSKgel Size Exclusion Chromatography Columns
Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:
More informationAGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography
Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationSuperose High-performance Columns
GE Healthcare Life Sciences Data file 18-1163-8 AC Gel filtration Superose High-performance Columns Superose prepacked columns are designed for highperformance, laboratory-scale separations of proteins
More informationSeparation of Structurally Similar Steroids on HALO C18 and PFP
Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationValidated HPLC Methods
Validated HPLC Methods To Tweak or Not to Tweak Slide 4 Adjustments of operating conditions to meet system suitability requirements may be necessary. USP 23 p1776 Slide 5 001816S1.PPT What is the line
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationCellufine Butyl Cellufine Phenyl
Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet Introduction For purification of proteins and macromolecules Hydrophobic Interaction Chromatography (HIC)
More informationBis sulfone Reagents. Figure 1.
Bis sulfone Reagents An intact IgG molecule has four accessible inter chain disulfide bonds that can be reduced to form eight free cysteine thiols, which can serve as sites for conjugation. The reaction
More informationSuperficially Porous Silica Particles with Wide Pores for Biomolecular Separations
Superficially Porous Silica Particles with Wide Pores for Biomolecular Separations B. M. Wagner, S. A. Schuster, B. E. Boyes, J. J. Kirkland Advanced Materials Technology, Inc. Wilmington, DE, USA Study
More informationLogical Method Development for Peptides and Proteins Using RP-HPLC and SEC
Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC Slide 4 001284P1.PPT Seminar Outline 1. Gel-filtration separations by SEC 2. Developing methods for protein and peptide separations
More informationHow to use GPC/SEC for compositional analysis
How to use GPC/SEC for compositional analysis Determining the relative concentration of two components in a polymer sample MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT Introduction Over the last
More informationDetermination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*
Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* EPA Method 8315A UCT Part Number: EUC1812M15 (Unendcapped C18-2000 mg/15 ml cartridge) March 2013 Method
More informationGFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents
No.038 GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series Contents Page 1. Introduction 2. Calibration curves, theoretical plate numbers and separation range
More informationCellufine Butyl Cellufine Phenyl
Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationWelcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster
Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm
More informationGPC/SEC An essential tool for polymer analysis
GPC/SEC An essential tool for polymer analysis Ben MacCreath, PhD Product Manager GPC/SEC Instrumentation 26 th March 2013 Introduction to Polymers Where are they found? Polyolefins Engineering Polymers
More informationTSKgel SW TSKgel SW XL TSKgel SuperSW. TSKgel PW TSKgel PW XL -CP. TSKgel Alpha TSKgel SuperAW. TSKgel H XL TSKgel H HR TSKgel Super H TSKgel Super HZ
8 www.tosohbioscience.com size exclusion CHROMATOGRAPHY Tosoh bioscience ANALYSIS sec size exclusion chromatography 9 size exclusion CHROMATOGRAPHY PRODUCTS TSK-GEL SW-type TSKgel SW TSKgel SW XL TSKgel
More informationAdvantages of polymerbased. an alternative for ODS
Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:
More informationSupporting Information. Copyright Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim, 2007
Supporting Information Copyright Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, 2007 Copyright Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, 2007 Supporting Information for Head-to-Tail Cyclized
More informationOptical Isomer Separation Columns and Packing Materials
02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31
More informationValue of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs
Value of Eclipse Plus C18 and ph Selectivity to Analyze Ae-Containing Drugs Application Pharmaceuticals Authors John W. Henderson Jr., William J. Long, and Cliff Woodward Agilent Technologies 285 Centerville
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationAnalysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns
Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns Application Note Bio-Pharmaceutical Author M.Sundaram Palaniswamy Agilent Technologies, Ltd India Abstract PEGylation of therapeutic proteins
More informationTips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography
Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography Daniela Held and Thorsten Hofe, PSS Polymer Standards Service GmbH, Mainz, Germany Gel permeation chromatography/size-exclusion
More informationPeptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen
Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters Application Angelika Gratzfeld-Huesgen Abstract This application has been verified using an Agilent
More informationtype GroEL-GroES complex. Crystals were grown in buffer D (100 mm HEPES, ph 7.5,
Supplementary Material Supplementary Materials and Methods Structure Determination of SR1-GroES-ADP AlF x SR1-GroES-ADP AlF x was purified as described in Materials and Methods for the wild type GroEL-GroES
More informationThe power of multi-detector SEC in the analysis of antibodies
The power of multi-detector SEC in the analysis of antibodies How OMNISEC can measure antibody absolute MW independent of size and structural changes MOLECULAR SIZE MOLECULAR STRUCTURE MOLECULAR WEIGHT
More informationMonitoring Protein PEGylation with Ion Exchange Chromatography
Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Leo Wang, Terry Zhang, and Jeffrey Rohrer 245 th ACS National Meeting & Exposition April 9, 213 OT7618_E 4/13S 1 The
More informationQUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3
Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long
More informationZirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationIon Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin
Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the
More informationPrep 150 LC System: Considerations for Analytical to Preparative Scaling
Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:
More informationCYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE
December 2008 CYCLOSERINE Final text for addition to The International Pharmacopoeia (November 2008) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications for Pharmaceutical
More informationFast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger
Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Pittcon 2005 BINGWEN YAN 1, CLAYTON V. MCNEFF 1, 1 ZirChrom Separations, Inc., 617 Pierce Street,
More informationHarris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS
Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS CHAPTER 25: Opener Aa CHAPTER 25: Opener Ab CHAPTER 25: Opener B 25-1 Ion-Exchange
More informationHPLC Column Selection: Solve the Separation Mystery. The world leader in serving science
HPLC Column Selection: Solve the Separation Mystery The world leader in serving science verview Introduction Historical verview in Stationary Phases Basics in Column Selection Resolution, Efficiency and
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationTEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD
APPENDIX V TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD Validating Chromatographic Methods. By David M. Bliesner Copyright 2006 John Wiley & Sons, Inc. 159 160 APPENDIX V Title: Effective: Document No:
More informationDissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.
Atorvastatin Calcium Tablets Type of Posting Posting Date 25 Jan 2019 Official Date 01 Feb 2019 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance In accordance with the Rules
More informationSimultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column
Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by PLC Deanna C. urum, Brian M. De Borba, and Jeffrey S. Rohrer Dionex Corporation, Sunnyvale, CA, USA ITRDUCTI Peptides perform
More informationTable S1. Overview of used PDZK1 constructs and their binding affinities to peptides. Related to figure 1.
Table S1. Overview of used PDZK1 constructs and their binding affinities to peptides. Related to figure 1. PDZK1 constru cts Amino acids MW [kda] KD [μm] PEPT2-CT- FITC KD [μm] NHE3-CT- FITC KD [μm] PDZK1-CT-
More informationRevision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance
Niacin Extended-Release Tablets Type of Posting Posting Date Official Date Expert Committee Reason for Revision Revision Bulletin 27 Jan 2017 01 Feb 2017 Non-Botanical Dietary Supplements Compliance In
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationRevision Bulletin 29 Dec Jan 2018 Non-Botanical Dietary Supplements Compliance
Niacin Extended-Release Tablets Type of Posting Posting Date Official Date Expert Committee Reason for Revision Revision Bulletin 29 Dec 2017 01 Jan 2018 Non-Botanical Dietary Supplements Compliance In
More informationNext Generation of Phenyl Columns. Chromatography Products.
Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both
More informationIn Situ Gelation-Induced Death of Cancer Cells Based on Proteinosomes
Supporting information for In Situ Gelation-Induced Death of Cancer Cells Based on Proteinosomes Yuting Zhou, Jianmin Song, Lei Wang*, Xuting Xue, Xiaoman Liu, Hui Xie*, and Xin Huang* MIIT Key Laboratory
More informationAPPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction
Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical
More informationDilution(*) Chromatography
WA20264 Poster # 184, HPLC 2002, Montreal, 4-5 June 2002 At-Column Column-Dilution for Preparative Dilution(*) Chromatography Cecilia Mazza, Jie Cavanaugh, Ziling Lu,Tom Sirard,Tom Wheat and Uwe Neue Waters
More informationPeptide Isolation Using the Prep 150 LC System
Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable
More informationHow proteins separate on reverse-phase HPLC
1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationfor Acclaim Trinity TM P1
for Acclaim Trinity TM P Product Manual for Acclaim TRINITY P Columns Page of 4 Product Manual for Acclaim Trinity TM P Columns 07556 Acclaim Trinity P, 3µm, 4.6 x 00mm 07556 Acclaim Trinity P, 3µm, 4.6
More informationSupporting Information for. PNA FRET Pair Miniprobes for Quantitative. Fluorescent in Situ Hybridization to Telomeric DNA in Cells and Tissue
Supporting Information for PNA FRET Pair Miniprobes for Quantitative Fluorescent in Situ Hybridization to Telomeric DNA in Cells and Tissue Orenstein, et al Page S2... PNA synthesis procedure Page S3...
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationSize-Exclusion Reaction Chromatography (SERC): A New Technique for Protein PEGylation
Size-Exclusion Reaction Chromatography (SERC): A New Technique for Protein PEGylation by Conan J. Fee Department of Materials & Process Engineering University of Waikato Private Bag 3105 Hamilton 2020
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationData sheet. UV-Tracer TM Biotin-Maleimide. For Labeling of Thiol-groups with UV-detectable Biotin CLK-B Description
Cat. No. CLK-B105-10 CLK-B105-100 Amount 10 mg 100 mg For in vitro use only! Quality guaranteed for 12 months Store at -20 C 1. Description UV-Tracer TM Biotin Maleimide for biotinylation reactions of
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationApplications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media
Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media Nandu Deorkar*, Wei Guo, Bob Buss, Joe Mladosich and Paul Bouis Mallinckrodt Baker Inc. 1904 J.T. Baker Way
More informationDr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1
Dr. Christoph Johann Wyatt Technology Europe GmbH 2010 Copyright Wyatt Technology Europe GmbH All Rights reserved 1 Introduction Overview The Nature of Scattered Light: Intensity of scattered light Angular
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationMACROIMS MACROION MOBILITY SPECTROMETER MOLECULAR WEIGHT AND PARTICLE SIZE DETERMINATION OF POLYVINYLPYRROLIDONE (PVP)
MACROIMS MACROION MOBILITY SPECTROMETER MOLECULAR WEIGHT AND PARTICLE SIZE DETERMINATION OF POLYVINYLPYRROLIDONE (PVP) APPLICATION NOTE CHEMC-009 (A4) Polyvinylpyrrolidone (PVP) Polymer Polyvinylpyrrolidone
More informationHigh Performance Liquid Chromatography
High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).
More informationMEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20
MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20 Introduction Protein aggregation is recognised as a major issue in the biopharmaceutical industry. Proteins have a tendency to aggregate over
More informationOligonucleotide Separation on ZirChrom -SAX
Technical Bulletin #166 Oligonucleotide Separation on ZirChrom -SAX Absorbance () 5 45 4 35 3 25 2 15 1 5 Analytes Poly (A)- hydrolysate 2 4 6 8 1 12 Time (Minutes LC Conditions Column: ZirChrom -SAX,
More informationTechnical Challenges in the Analysis of PEGylated Proteins by Capillary Electrophoresis
Technical Challenges in the Analysis of PEGylated Proteins by Capillary Electrophoresis Ying-Chen Chen Biologics Process & Product Development Hopewell, NJ Outline PEGylation background information CE-SDS
More informationIsolation & Purification of Proteoglycans (PGs) and Glycosaminoglycans (GAGs) PEG Trainee Lecture July 23, 2012
Isolation & Purification of Proteoglycans (PGs) and Glycosaminoglycans (GAGs) PEG Trainee Lecture July 23, 2012 Most Common Extraction Procedure for PGs 4 M Guanidine-HCl Detergents such as 2% CHAPS or
More informationAnalytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals
Analytical Methods to Qualify and Quantify and ylated Biopharmaceuticals Christopher Crafts, Bruce Bailey, Marc Plante, Ian Acworth Thermo Fisher Scientific, Chelmsford, MA Application Note 1015 Key Words
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationWilliam E. Barber, Ph.D. Applications Chemist October
William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC
More informationYour Reversed Phase Method
PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust
More informationChoosing Columns and Conditions for the Best Peak Shape
Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include
More informationAnalysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system
Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system Application Note Food Testing & Agriculture Authors Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Keiko
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More information