Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS
|
|
- Dwayne Russell
- 6 years ago
- Views:
Transcription
1 Designed for Accuracy High resolution quantitative proteomics Innovation with Integrity LC-MS
2 Setting New Standards in Accuracy The development of mass spectrometry based proteomics approaches has dramatically improved researchers capabilities of characterizing the protein content of biological systems, while simultaneously offering information on proteins identity, abundance and modifications. Accurate and reproducible protein quantitation is key for success and Bruker s latest UHR-QTOF platforms are designed to provide the best performance in this area. The Instant Expertise acquisition methods provide easy and straightforward access to the underlying biology. Generic quantitation workflows Chromatographic separation Ionization Extracted proteins from biological samples Peptides Digestion Chromatographic separation CaptiveSpray + nanobooster
3 Accuracy = Resolution x Sensitivity Full Sensitivity Resolution (FSR) In traditional QTOF architecture, high resolution is obtained at the price of ion losses through slits or multiple reflections and the maximal sensitivity is therefore not accessible at full resoultion. The Bruker FSR architecture, in contrast, makes use of the maximum number of ions to obtain the highest resolution available without sensitivity loss. This ensures the best possible selectivity and sensitivity, at any speed. Whatever strategy is chosen for quantitative mass spectrometry based analysis of complex proteomics samples, the most important aspect is accurate determination of ratios both in single runs or large sample cohorts. Data acquisition Post processing Quantitative results proteinscape MaxQuant Perseus impact II Skyline
4 Repeatable High Performance The impact II s unique combination of sensitive, high resolution and high dynamic range spectra opens a new dimension in MS based quantitation. Both label-free quantitation workflows and quantitation based on chemical labels are very easy to implement with pre-set methods. Preservation of spectral quality in MS/MS mode guarantees optimal performance for these data dependant acquisition (DDA) approaches. Instant Expertise The impact II s default ID/Quant acquisition method ensures accurate MS based quantitation with regular spacing of MS events. The number of MS/MS events and the corresponding acquisition speed is adapted depending on parent ion intensity. Optimal MS/MS based quantitation is ensured by transfer time stepping functionality that allows high sensitivity over the entire mass range. Instant Expertise Instant Expertise for label free and metabolic labels Optimal chromatographic shape for accurate quantitation High resolution for more selectivity Instant Expertise for isobaric chemical labels Broadband MS/MS transfer for optimal reporter ion quantitation and peptide identification Instant Expertise label free and metabolic labels Instant Expertise isobaric chemical labels MS spectrum from potato root digest in an LC-MS/MS experiment showing >50,000 resolution for a selected parent ion. (Data courtesy of Dr. Hans Peter Mock, IPK Gatersleben) itraq8 MS/MS spectrum from E.coli digest spiked with four proteins at ratios 10:10:5:5:2:2:1:1. (Samples courtesy Dr. David Ashford, York University)
5 Across the Whole Range The impact II allows targeted proteomics experiments to be run in either an MS based format or at the MS/MS level based on data independent acquisition (DIA). Superior resolution and full sensitivity of MS and MS/MS spectra facilitate both approaches on the impact II. Low method development requirements Data aquisition in MS mode for targeted peptide and protein quantitation provides accurate results over a large dynamic range based on high resolution extracted ion chromatograms (Hr-XIC). This mode is applicable to both high and low complexity samples and both approaches benefit from the uncompromised resolution and sensitivity of the impact II. In DIA, the relevant mass range for proteomics is covered by larger isolation windows to obtain high resolution MS and MS/MS information of each peptide contained in the sample. Targeted HR-XIC Data Independent Acquisition (DIA) Read more: Bruker Daltonics Application Note LCMS-89 Ceruloplasmin peptide quantitation Ceruloplasmin peptide quantitation over 4 orders of magnitude (10 amol fmol/µl) in non depleted plasma.
6 Label-Free Intact Protein Analysis Peptide based quantitation is a very sensitive approach but it is blind to some essential biological events such as protein proteolysis. By combining Full Sensitivity Resolution with the True Isotopic Pattern (TIP ) capability of Bruker s UHR-QTOF systems, accurate measurement of intact proteins is readily available, even in complex mixtures. The Dissect and SNAP algorithms extract the accurate mass and intensity information to perform a direct label free approach on intact proteins. Dissect Dissect processing of an E.Coli lysate separated with a 20 min gradient recovers more than 120 coelution peaks, corresponding to more than 800 distinct proteoforms. SNAP Deconvoluted intact protein spectrum after 5.2 min. The monoisotopic mass was calculated using SNAP that takes the experimentally determined very accurate isotopic pattern (True Isotopic Pattern) into account. Statistical analysis of label free protein profiling study Volcano plot displaying quantitative results. Read more: Bruker Daltonics Poster Note PN-04
7 Label-Free Shotgun Proteomics Accuracy of the label free quantitation (ID/Quant) workflow Thanks to the combination of very stable nano electrospray (CaptiveSpray ) and advanced QTOF technology, the impact II offers robust and accurate labelfree quantitation. Since this strategy relies on every single peptide precursor ion that is detected at the MS level, the benefit of high resolution over the entire mass range directly translates into superior ratio determination. Control Digestion LC-MS/MS Peak intensity Sample Quant accuracy over a large dynamic range 500 ng of yeast digest were spiked with UPS2 protein standard (Sigma-Aldrich, P/N UPS2) in a 1:2 ratio. After injection, UPS 2 proteins were identified and quantified over 4 orders of dynamic range, despite the small ratio difference. (Data courtesy S. Beck et al, MaxPlanck Institute for Biochemistry, Martinsried, Germany) Read more: Journal of the MCP: The impact II, a very high resolution quadrupole time-of-flight instrument for deep shotgun proteomics
8 Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL , Verified by Science The impact II provides latest Bruker UHR-QTOF technology The unique combination of quantitative accuracy, dynamic range and reproducibility make the system capable of delivering quantitative data with best accuracy. CaptiveSpray nanobooster Source Zero adjustment for excellent reproducibility Acetonitril dopant for improved sensitivity Full-Sensitivity-Resolution Technology 50,000 resolving power at MS and MS/MS level without compromising sensitivity or acquisition speed Highly accurate extracted ion chromatogram (1-2 mda) Patented Dual Ion Funnel Optimized ion transmission Off axis ion inlet for improved robustness 50 Gbit/s Detection System High intra spectral dynamic range at LC-MS speed Collision Cell Improved transmission for optimal sensitivity Wide m/z transfer TOF technology has fundamental attractions, such as the extremely high scan speed and the absence of space charge, which limits the number of usable ions in all trapping instruments. TOF instruments [are] capable of making use of the majority of ions, thus promising optimal sensitivity, dynamic range and hence quantification. It appears that QTOFs are set to make a comeback in proteomics with recent examples demonstrating impressive depth of coverage of complex proteomes. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen Germany Phone +49 (0) Fax +49 (0) Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) Fax +1 (978) ms.sales.bdal@bruker.com -
TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform
More informationPesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS
PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop
More informationmicrotof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF
microtof-q III The bench-mark in accurate mass LC-MS/MS Innovation with Integrity ESI-Qq-TOF The Advantage of Confidence in Routine The microtof-q range is widely acknowledged in setting standards in performance
More informationBruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward
Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated
More informationHigh-Throughput Protein Quantitation Using Multiple Reaction Monitoring
High-Throughput Protein Quantitation Using Multiple Reaction Monitoring Application Note Authors Ning Tang, Christine Miller, Joe Roark, Norton Kitagawa and Keith Waddell Agilent Technologies, Inc. Santa
More informationprofileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research
profileanalysis Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research Innovation with Integrity Omics Research Biomarker Discovery Made Easy by ProfileAnalysis
More informationThe Power to See What You ve Never Been Able to See Before. Innovation with Integrity. Qq-FTMS
The Power to See What You ve Never Been Able to See Before Innovation with Integrity Qq-FTMS Now see what you ve never been able to see Bruker s extreme Resolution FTMS technology enables scientists to
More informationImproved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer
Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher
More informationHigh-Field Orbitrap Creating new possibilities
Thermo Scientific Orbitrap Elite Hybrid Mass Spectrometer High-Field Orbitrap Creating new possibilities Ultrahigh resolution Faster scanning Higher sensitivity Complementary fragmentation The highest
More informationBruker Daltonics. microtof-q. Cutting Edge Performance with Sub-ppm Confidence. ESI-Qq TOF. think forward
Bruker Daltonics microtof-q Cutting Edge Performance with Sub-ppm Confidence think forward ESI-Qq TOF The advantage of ultimate confidence Do you need maximum confidence in your analytical system? Bruker
More informationProtein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University
Protein Quantitation II: Multiple Reaction Monitoring Kelly Ruggles kelly@fenyolab.org New York University Traditional Affinity-based proteomics Use antibodies to quantify proteins Western Blot RPPA Immunohistochemistry
More informationProtein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University
Protein Quantitation II: Multiple Reaction Monitoring Kelly Ruggles kelly@fenyolab.org New York University Traditional Affinity-based proteomics Use antibodies to quantify proteins Western Blot Immunohistochemistry
More informationHR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput
HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput Yi Zhang 1, Zhiqi Hao 1, Markus Kellmann 2 and Andreas FR. Huhmer
More informationApplication Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides
Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Abstract Here we describe a two-step QC procedure for synthetic peptides. In the first step, the
More informationApplication Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics
Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics Introduction Determining the structure of secondary metabolites
More informationProven robustness for large-scale metabolomics studies using the Phenomics Workhorse
Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse HRAM LC-MS profiling of > 1 urine samples demonstrates the outstanding analytical skills of the impact II Introduction
More informationAnalysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics
Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics Lee Gethings, Gushinder Atwal, Martin Palmer, Chris Hughes, Hans Vissers, and James Langridge Waters Corporation, Wilmslow,
More informationAt-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =
Application ote #LC-MS 80 Simultaneous Quantitative and Qualitative Measurements in a Single Workflow to Increase Productivity in Primary Drug Metabolism Investigations At-a-Glance n Increased productivity
More informationPerforming Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition
Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition Yun Wang Alelyunas, Mark D. Wrona, and Nick Tomczyk Waters Corporation, Milford, MA, USA GOAL
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationApplication Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis
Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationPeptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA
Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA Proteomics is Turning Quantitative Hmmm.. Which ones are my targets?
More informationImproved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *
Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 * 1 Department of Chemistry, Pomona College, Claremont, California
More informationQuadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365
Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest
More informationMS-based proteomics to investigate proteins and their modifications
MS-based proteomics to investigate proteins and their modifications Francis Impens VIB Proteomics Core October th 217 Overview Mass spectrometry-based proteomics: general workflow Identification of protein
More informationQuantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays
: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability
More informationTargeted protein quantification
Targeted Quantitative Proteomics Targeted protein quantification with high-resolution, accurate-mass MS Highly selective Very sensitive Complex samples HR/AM A more complete quantitative proteomics picture
More informationWALKUP LC/MS FOR PHARMACEUTICAL R&D
Pharmaceutical Workflow Solutions WALKUP LC/MS FOR PHARMACEUTICAL R&D Chemists, Peptide/Protein Chemists, Biologists, and Beyond MASSHUNTER WALKUP A Single User Interface for Robust and Reliable LC/MS
More informationWADA Technical Document TD2003IDCR
IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must
More informationThe Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics
APPLICATION NOTE TOF MS The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics Purpose The Applied Biosystems 4700
More information[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.
[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly. Xevo G2 Tof Quantitative and qualitative answers from a single analysis. For scientists who need to confidently identify and
More informationIntroduction. Authors
IROA C12 (5%) IROA C13 (95%) # of carbons Application Note LCMS-88 Isotopic Ratio Outlier Analysis (IROA ) coupled with the Bruker maxis 4G QTOF to investigate changes in the secondary metabolite profiles
More informationAccurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies
Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF Application Note Donghui Yi and Christine Miller Jon D. Williams, GlaxoSmithKline Introduction Mass spectrometry (MS) has become a core technology
More informationRapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS
Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,
More informationThe Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance
The Agilent 495 Triple Quadrupole LC/MS: Peptide Quantitation Performance Technical Overview Introduction Sample complexity and the low concentration of certain biomarkers are the major challenges encountered
More informationRelative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer
POSTER NOTE 6558 Relative quantification using TMT11plex on a modified mass spectrometer Authors Tabiwang N. Arrey, 1 Rosa Viner, 2 Ryan D. Bomgarden, 3 Eugen Damoc, 1 Markus Kellmann, 1 Thomas Moehring,
More informationTranslational Biomarker Core
Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra
More informationSimplified Approaches to Impurity Identification using Accurate Mass UPLC/MS
Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION
More informationMass Spectrometry and Proteomics - Lecture 5 - Matthias Trost Newcastle University
Mass Spectrometry and Proteomics - Lecture 5 - Matthias Trost Newcastle University matthias.trost@ncl.ac.uk Previously Proteomics Sample prep 144 Lecture 5 Quantitation techniques Search Algorithms Proteomics
More informationMultiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer
Application ote: 54 Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap rbitrap Hybrid Mass Spectrometer Kate Comstock, Yingying Huang; Thermo Fisher Scientific,
More informationIsotopic-Labeling and Mass Spectrometry-Based Quantitative Proteomics
Isotopic-Labeling and Mass Spectrometry-Based Quantitative Proteomics Xiao-jun Li, Ph.D. Current address: Homestead Clinical Day 4 October 19, 2006 Protein Quantification LC-MS/MS Data XLink mzxml file
More informationGuide to Peptide Quantitation. Agilent clinical research
Guide to Peptide Quantitation Agilent clinical research Peptide Quantitation for the Clinical Research Laboratory Peptide quantitation is rapidly growing in clinical research as scientists are translating
More informationQuantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry
Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry Jon Hao, Rong Ye, and Mason Tao Poochon Scientific, Frederick, Maryland 21701 Abstract Background:
More informationProteome-wide label-free quantification with MaxQuant. Jürgen Cox Max Planck Institute of Biochemistry July 2011
Proteome-wide label-free quantification with MaxQuant Jürgen Cox Max Planck Institute of Biochemistry July 2011 MaxQuant MaxQuant Feature detection Data acquisition Initial Andromeda search Statistics
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationTechnical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements
Bruker Daltonics Technical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements The amazon mass spectrometer platform The amazon TM series represents a new generation
More informationPosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction
Introduction The study of protein expression allows a greater understanding of biological function and can now routinely be performed using mass spectrometry. However, analysis of the post-translational
More informationAll Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems
All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution
More informationSupporting Information
Supporting Information Online Hydrophobic Interaction Chromatography-Mass Spectrometry for the Analysis of Intact Monoclonal Antibodies Bifan Chen a, Ziqing Lin b,c, Andrew J. Alpert d, Cexiong Fu e, Qunying
More informationChemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward
Chemical Analysis PIONA+ Analyzer Characterization of Engine Fuels by Hydrocarbon Group Type think forward Gas Chromatography Bruker 450 PIONA+ Analyzer Bruker s innovative PIONA+ TM Analyzer provides
More informationA Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance
A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,
More informationThermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos
More informationIsotope Dilution Mass Spectrometry
Isotope Dilution Mass Spectrometry J. Ignacio Garcia Alonso and Pablo Rodriguez-Gonzalez Faculty of Chemistry, University of Oviedo, Oviedo, Spain E-mail: jiga@uniovi.es, rodriguezpablo@uniovi.es RSC Publishing
More informationComputational Methods for Mass Spectrometry Proteomics
Computational Methods for Mass Spectrometry Proteomics Eidhammer, Ingvar ISBN-13: 9780470512975 Table of Contents Preface. Acknowledgements. 1 Protein, Proteome, and Proteomics. 1.1 Primary goals for studying
More informationMRMS axelerate rapidly detected micropollutants and plant response metabolites in poplar leaves
MRMS axelerate rapidly detected micropollutants and plant response metabolites in poplar leaves MRMS axelerate is demonstrated to be a new and powerful workflow to rapidly profile plant extracts in a context
More informationAnalytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1
More informationNew Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses
New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller
More informationINTRODUCTION OVERVIEW
COMPARISON OF CCS(N 2 ) MEASUREMENTS OBTAINED FROM TWO DIFFERENT T-WAVE ION S WITH DIRECT MEASUREMENTS USING A DRIFT TUBE ION Kevin Giles, Martin Palmer, Keith Richardson, Nick Tomczyk Waters MS Technologies
More informationIdentifying Disinfection Byproducts in Treated Water
Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction
More informationAmine specific Labeling Reagents for Multiplexed Relative and Absolute Protein Quantitation
Product Bulletin itraq Reagents itraq Reagents Amine specific Labeling Reagents for Multiplexed Relative and Absolute Protein Quantitation Background Proteomics research includes the characterization of
More informationTomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories
APPLICATION NOTE 65200 Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories Authors Neloni Wijeratne, Claudia Martins, Mary
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationQuan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm
26.1645 165.91 33.267 Thermo Scientific Q Exactive rbitrap LC-MS/MS System Unmatched Confidence for Quan/Qual Analyses Identify Quantify Confirm Quanfirmation \ kwän-f r-'m -shän\ n 1 : the ability to
More informationTandem mass spectra were extracted from the Xcalibur data system format. (.RAW) and charge state assignment was performed using in house software
Supplementary Methods Software Interpretation of Tandem mass spectra Tandem mass spectra were extracted from the Xcalibur data system format (.RAW) and charge state assignment was performed using in house
More information6 x 5 Ways to Ensure Your LC-MS/MS is Healthy
6 x 5 Ways to Ensure Your LC-MS/MS is Healthy (Also known as - Tracking Performance with the 6 x 5 LC-MS/MS Peptide Reference Mixture) Mike Rosenblatt, Ph.D. Group Leader Mass Spec Reagents 215. We monitor
More informationCharacterization of petroleum samples via thermal analysis coupled to APCI FTMS
Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Abstract Thermal analysis, by means of a thermo balance (TG), was coupled to an atmospheric pressure chemical ionization
More informationA DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification
A DIVISION OF ULVAC-PHI Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification Designed for Confident Molecular Identification and Superior Imaging
More informationIR Biotyper. Innovation with Integrity. Microbial typing for real-time epidemiology FT-IR
IR Biotyper Microbial typing for real-time epidemiology Innovation with Integrity FT-IR IR Biotyper - Proactive hospital hygiene and infection control Fast, easy-to-apply and economical typing methods
More informationApplication Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry
Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry Introduction The oil industry requires detailed information on the composition of
More informationApplication Note GCMS-03 Reliable high-throughput quantification of melamine and related analogs below regulatory limits in food using the EVOQ GC-TQ
Application Note GCMS03 Reliable highthroughput quantification of melamine and related analogs below regulatory limits in food using the EVOQ GCTQ Introduction is a molecule that presents a high content
More informationThermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap
m a s s s p e c t r o m e t r y Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap World's fastest and most sensitive ion trap mass spectrometer Part of Thermo Fisher Scientific Thermo Scientific
More informationMatching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology
Matching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology Superior Results for Complex Sample Analyses Technical Overview Separation Speed Peak Capacity Signal Response Chromatogram
More informationMass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS
Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from
More informationApplication Note. Edgar Naegele. Abstract
Fast identification of main drug metabolites by quadrupole time-of-flight LC/MS Measuring accurate MS and MS/MS data with the Agilent 651 Q-TOF LC/MS and identification of main meta-bolites by comparison
More informationChoosing the metabolomics platform
GBS 748 Choosing the metabolomics platform Stephen Barnes, PhD 4 7117; sbarnes@uab.edu So, I have my samples what s next? You ve collected your samples and you may have extracted them Protein precipitation
More informationTutorial 2: Analysis of DIA data in Skyline
Tutorial 2: Analysis of DIA data in Skyline In this tutorial we will learn how to use Skyline to perform targeted post-acquisition analysis for peptide and inferred protein detection and quantitation using
More informationThermo Finnigan LTQ. Specifications
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications
More informationSEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW
SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been
More informationUCD Conway Institute of Biomolecular & Biomedical Research Graduate Education 2009/2010
EMERGING PROTEOMIC TECHNOLOGIES - MODULE SCHEDULE & OUTLINE 2010 Course Organiser: Dr. Giuliano Elia Module Co-ordinator: Dr Giuliano Elia Credits: 5 Date & Time Session & Topic Coordinator 14th April
More informationDIA-Umpire: comprehensive computational framework for data independent acquisition proteomics
DIA-Umpire: comprehensive computational framework for data independent acquisition proteomics Chih-Chiang Tsou 1,2, Dmitry Avtonomov 2, Brett Larsen 3, Monika Tucholska 3, Hyungwon Choi 4 Anne-Claude Gingras
More informationIdentification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate
Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationTutorial 1: Setting up your Skyline document
Tutorial 1: Setting up your Skyline document Caution! For using Skyline the number formats of your computer have to be set to English (United States). Open the Control Panel Clock, Language, and Region
More informationPowerful Scan Modes of QTRAP System Technology
Powerful Scan Modes of QTRAP System Technology Unique Hybrid Triple Quadrupole Linear Ion Trap Technology Provides Powerful Workflows to Answer Complex Questions with No Compromises While there are many
More informationfor the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York
Mass Spectrometry for the Novice John Greaves and John Roboz (^>, yc**' CRC Press J Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa business
More informationA Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies
A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationConfirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System
Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System Claire Bramwell-German, Elliott Jones and Daniel Lebre AB SCIEX, Foster City, California
More informationChemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.
Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes
More informationLECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile
LECTURE-11 Hybrid MS Configurations HANDOUT PREAMBLE As discussed in our previous lecture, mass spectrometry is by far the most versatile technique used in proteomics. We had also discussed some of the
More informationIncreasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer
Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance
More informationETD Verification Kit II
Instructions for Use ETD Verification Kit II Kit for verifying and tuning electron transfer dissociation (ETD) and proton transfer reaction (PTR) CARE products are designed to support our worldwide customers
More informationAchieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer
APPLICATION NOTE 72385 Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer Authors Stephan Meding, Katherine Lovejoy, Martin Ruehl Thermo Fisher Scientific,
More informationETD Verification Kit
Instructions for Use ETD Verification Kit Kit for verifying and tuning electron transfer dissociation (ETD) CARE products are designed to support our worldwide customers with highquality consumables, accessories
More informationReagents. Affinity Tag (Biotin) Acid Cleavage Site. Figure 1. Cleavable ICAT Reagent Structure.
DATA SHEET Protein Expression Analysis Reagents Background The ultimate goal of proteomics is to identify and quantify proteins that are relevant to a given biological state; and to unearth networks of
More informationChemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics
Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics mtraq Reagents Triplex Christie Hunter, Brian Williamson, Marjorie Minkoff AB SCIEX, USA The utility
More informationMassHunter Software Overview
MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A
More informationMassHunter TOF/QTOF Users Meeting
MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks
More informationFundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics
Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass
More information