Transcription

1

2

3

4 DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion: Once approved, the new or revised document or the notice of deleted document(s) should be distributed to all persons identified below: ( ) All RP staff members ( X ) All holders of the following manual(s): SLAC Radioanalysis Laboratory Procedures ( ) The following individuals: November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 4

5 TABLE OF REVISIONS REVISION DATE SECTION(S) REASON FOR REVISION # 001 March 11, 2003 B, C, D, K, Prevent Generation of Mixed Waste By Changing Sample to Cocktail Ratio 002 July 16, 2003 B, C. D, K, Increase efficiency and lower count times 003 November 17, 2006 All Rewrite of procedure to incorporate LSC Source Check procedure. LSC Counting checklist added to appendix. November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 5

6 TABLE OF CONTENTS LSC Procedure 1 PURPOSE REFERENCES RESPONSIBILITIES Rad Lab Operator REP Manager PREREQUISITES PROCEDURES Perform a Source Check Prepare the Sample Count the Sample Determine the Results Dispose of the sample RECORDS ATTACHMENTS/FORMS Attachment 1: Routine Liquid Scintillation Counting Checklist November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 6

7 1 PURPOSE LSC Procedure The purpose of this procedure is to provide general guidance for operating the Liquid Scintillation Counter (LSC). The LSC Sample Counting procedure applies to anyone characterizing liquid samples in the Radioanalysis Laboratory (Rad Lab). This procedure outlines the steps for counting LSC samples. A Routine Scintillation Counting Checklist (Attachment 1) is attached to provide detailed instructions for routine LSC counting using current Rad Lab equipment. Refer to instrument specific operating manuals when performing LSC analysis with non-rad Lab equipment. 2 REFERENCES 2.1 Packard Tri-Carb 1900TR Operational Manual 2.2 SLAC Rad Lab Manual, General Sample Analysis Procedure 3 RESPONSIBILITIES 3.1 Rad Lab Operator The Rad Lab Operator assigned to perform activities described in this chapter is responsible for: ensuring that prerequisites are met as required, maintenance of the laboratory equipment and performing daily quality control checks, reporting any problems or unexpected events to the Radiological Environmental Protection (REP) Manager, routine sample analysis counting, providing the data to the REP Manager for analysis and approval, and Performing other duties assigned by the REP Manager. 3.2 REP Manager The REP Manager is responsible for: ensuring that the activities in this chapter are conducted in accordance with this written procedure, November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 7

8 LSC Procedure assigning the tasks in this procedure to a qualified operator, and providing final approval or disapproval of all data and submittals. 4 PREREQUISITES 4.1 Must be familiar with Windows operating menus, Microsoft Access and Notepad. 4.2 Must be familiar with Rad Lab general sample analysis procedures 4.3 Must have a basic understanding of Liquid Scintillation Counting theory 4.4 Must be familiar with general laboratory equipment and methods (pipettes, scales, distillation etc.) 5 PROCEDURES 5.1 Perform a Source Check As part of the instrument quality control process, the Self Normalization and Calibration (SNC) protocol should be run daily when the LSC system is in use. The SNC protocol is performed by counting the H-3, C-14, and background standards in the SNC labeled tray. A generated report displays H-3 and C-14 efficiencies upon completion of the SNC protocol. These values are reviewed to determine if the LSC is operating within specifications. Acceptable values are listed in the instrument s operational manual. If the efficiencies are not within specifications, the LSC should be repaired as needed. Otherwise sample counting can proceed. 5.2 Prepare the Sample Sample preparation requires the use of appropriate PPE. At a minimum latex gloves and eye protection should be used. A pipette, tips, vials, and liquid scintillation cocktail fluid are necessary supplies in order to prepare the sample. General sample preparation is performed by marking a liquid scintillation vial with the sample number, pipetting a volume of the sample into the vial, and adding scintillation cocktail to help facilitate the detection of radiation. After capping the vial the samples are placed in the appropriate protocol tray and are ready for counting. There are some samples that require special preparation prior to counting. Swipes, for instance, require additional sitting time once cocktail is added in November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 8

9 LSC Procedure order to allow for the swipe to dissolve. Refer to the checklist (Attachment 1) for more specific instructions on how to handle these special cases. 5.3 Count the Sample Determine the counting protocol for the sample. For instance, LCW samples are counted under protocol 1 for 30 minutes and environmental/well samples count under protocol 13 for 250 minutes. Refer to the checklist (Attachment 1) to determine the appropriate counting protocol. Samples are to be counted in sets. Each set must include at least one background sample. Each set must also include quality control samples. As a minimum two identical spiked blanks must be included. The spiked blanks are used to calculate quality control statistics as well as confirm quality control during batch counting. 5.4 Determine the Results Upon completion of counting a report is generated by the LSC. The results should be reviewed for any unusual trends. Examples are high luminosity (LUM >30) values and large DPM deviations between the spiked blanks. A high CPMC (2X background) may indicate the need for Gamma spectroscopy. In some cases there may be spillover into the tritium channel from other nuclides. Distillation may be required to determine actual tritium content. Make sure that the batch background results are in agreement with the background counts for the source check. Contact the REP or FO manager if any unusual trends appear. The following formula is used to calculate the tritium concentration in pci/l: (Sample DPM - BKG DPM)*X = pci/l Conversion factor X=(1/SV)*(1000ml/L)*(1pCi/2.22DPM) where: SV is the volume of sample in the vial. So for SV= 5.0 ml: X= (1/5.0 ml) * (1000ml/l)*(1pCi/2.22DPM) X= 91 pci/l-dpm The minimum detectable activity depends on the counting protocol used (see Attachment 1). If the sample results are less than or equal to the applicable MDA, the sample activity is reported as No Detectable Activity (NDA). If the sample results exceed the applicable MDA, report the sample activity in pci/l. November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 9

10 LSC Procedure 5.5 Dispose of the sample 6 RECORDS Upon completion of analysis LSC vials (including contents) are discarded in the appropriate waste container. There is a satellite accumulation area where the waste containers are stored. The chemical and radiological characteristics of the samples determine their waste streams. Refer to the checklist (see Attachment 1) to determine the correct waste receptacle for each LSC vial. The sample, container, and release documentation are returned to the customer. A copy of the documentation is filed in the Rad Lab archive. 6.1 All analysis results generated from this procedure must be entered into the REP Rad Lab database on the network drive to ensure data access, security control, and backup. 6.2 All hardcopies of the Analysis reports generated from this procedure should also be provided and stored in the Rad Lab archives. 7 ATTACHMENTS/FORMS 7.1 Attachment 1: Routine Liquid Scintillation Counting Checklist November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 10

11 LSC Procedure 7.1 Attachment 1: Routine Liquid Scintillation Counting Checklist Done? Step No. Item [ ] 1. Complete Steps 1 7 of Sample Analysis Checklist (SAC). [ ] 2. If the monitor for LSC is not illuminated, pull out the keyboard & depress space key. [ ] 3. Confirm that display shows STATUS PAGE in upper left corner. If not, don t proceed, notify the REP or FO mgr. [ ] 4. If a source check is not required (see step 7 of SAC), proceed to Step 9. Perform Source Check [ ] 5. Source check: Confirm that the SNC tray is in the LSC that the standard H-3, C-14, & background vials are in that tray. Handle the vials by their caps; fingerprints on the vials may produce errors during Self normalization and Calibration (SNC) [ ] 6. Move the flag on the SNC tray to the left. [ ] 7. If STATUS PAGE shows the LSC mode as IDLE at the top center of screen, press [F2] on keyboard to start the count. [ ] 8. When the count of the standards is complete, review the print-out. Consult with the REP or FO mgr if: C14 Eff < 94% or H3 Eff <58% or Bkg ( kev) > 25 cpm or Bkg (0-156 kev) > 50 cpm [if this last background count rate is high, check neutron source use in Cal Lab). Prepare the Sample [ ] 9. Label a vial cap with the Sample ID printed on the sample bottle label. Put on gloves. [ ] 10. Verify that the Ultima Gold scintillation fluid dispenser is set for 5 ml [ ] 11. If preparing a sample with a swipe, skip to Step 15. Otherwise proceed with Step 12. November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 11

12 Done? Step No. Item LSC Procedure [ ] 12. Add 15 ml scintillation fluid (three pipettes-full) to an empty vial. [ ] 13. Place new tip (10 ml) on pipette, verify pipette is set for 5 ml. [ ] 14. Carefully pipette 5 ml of liquid from the sample bottle to the vial (be careful to avoid drips). Immediately discard the pipette tip using the Rad lab waste receptacle. Cap the sample bottle and the vial. Skip to Step 17. [ ] 15. To prepare a LSC vial for a swipe, put the swipe in the vial. [ ] 16. Pipette 5 ml of tap water into the vial. Add 15 ml scintillation fluid to the vial with the swipe. [ ] 17. Cap the vial with the cap (labeled with sample ID) & shake it. Allow the vial to sit long enough to dissolve (~ 30 min.). [ ] 18. Discard gloves using bin labeled for pipettes & gloves. Count the Sample [ ] 19. Determine the LSC protocol required for the sample. All samples collected by EP (e.g. water collected for storm water analysis) and ALL samples from groundwater wells (regardless of who collected) must be counted using Protocol 13; other samples may use Protocol 1 or 13, depending on the sample and the location. [ ] 20. Place the appropriate background standard in the corresponding protocol tray (1 or 13). In the adjacent slots, place the BKG standard, then the standard STD1, next the sample(s), & finally standard STD2. If any of the vials are for swipes, include the vial with the background swipe in the tray. Likewise, if you have a vial with an oil, well, or MCC sample, include the appropriate background standard. Standards STD1 & STD2 are de-ionized water with nearly identical H-3 concentrations. [ ] 21. Push the protocol flag to the left & place the tray in the LSC. [ ] 22. If STATUS PAGE shows the LSC mode as IDLE at the top center, press [F2] on keyboard to start the count. Determine the Results November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 12

13 Done? Step No. Item LSC Procedure [ ] 23. When the count is complete, label the results on the print-out, clearly writing the background, standard, and sample ID next to the applicable count for each. 24. Review the print-out. If the value in CPMC is about same (< 2X Bkg) for the sample as for the background vial, skip to Step 26. Otherwise, if CPMC for sample is higher (~double or more), then alert the REP program manager to determine if GS is needed. [ ] 25. On LSC print-out, consult with the REP or FO mgr if: 1) Within any one column (CPMA or A:2S% or CPMB or CPMC or SIS or tsie or LUM of DPM1) the values recorded for STD1 & STD2 are not similar, or 2) For any standard or sample, CPMB > CPMA or CPMA >> CPMB, or 3) For any sample the value in SIS is very different (e.g. double or half) from that for the BKG LCW standard. 4) For any sample, the value for tsie isn t w/ in a few hundred of the value for the standards, or 5) For any sample, the value for LUM is high (e.g. 40 or 50), or 6) The column FLAG has an indicator. [ ] 26. If previous step OK, determine the amount of H-3. To calculate the concentration, C, in a liquid, use the following formula: C(pCi/L) = (Sample DPM Bkg DPM) x 91 For a swipe no calculation is needed. If the sample DPM is > 1000, notify the FO manager to determine if additional swipes are needed. If sample DPM <1000, then the swipe is NDA. [ ] 27. Record the results, identified by sample ID, on the print out. [ ] 28. If the results are unexpected (e.g. H-3 detected in a location or well where H-3 has not been detected in past or no H-3 in a location or well that normally has H-3), alert the REP or FO mgr immediately. November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 13

14 Done? Step No. Item LSC Procedure [ ] 29. Mark any counted vial that was found to contain radioactivity (at or above the detection limit) with a radioactive materials label. Dispose of sample and Complete Sample Analysis Checklist [ ] 30. Discard the counted LSC vial into one of the three satellite accumulation bins: All rad vials (regardless of origin) Non-rad vials containing water from a SLAC well All non-rad vials, EXCEPT ones that contain water from a SLAC well. [ ] 31. Complete Steps 9 end of Sample Analysis Checklist (information on labeling & storage or return of sample is included in that procedure). November 27, 2006 SLAC-I-760-2A39C-008-R-003 Page 14

DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion

DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion: Once approved, the new or revised document or the notice of deleted document(s) should be distributed to all

More information

SLAC Radioanalysis Laboratory

SLAC Radioanalysis Laboratory SLAC Radioanalysis Laboratory Henry Brogonia Dosimetry and Radiological Protection Group (DREP) DOE Environmental Radiation Protection Program Review (July 23-24, 2007) Radioanalysis Laboratory Mission

More information

DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion

DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion: Once approved, the new or revised document or the notice of deleted document(s) should be distributed to all

More information

ANALYSIS Safety Information for the University of California, Berkeley JOB WASTE RADIOACTIVE SAMPLING LIQUID EALTH & SAFETY R TASK HAZARDS CONTROLS

ANALYSIS Safety Information for the University of California, Berkeley JOB WASTE RADIOACTIVE SAMPLING LIQUID EALTH & SAFETY R TASK HAZARDS CONTROLS This template is a Microsoft Word table use MS Word s online Help feature for instructions about how to add text and format tables. JOB SAFETY ANALYSIS Safety Information for the University of California,

More information

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106.

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106. QAM-RI.106 Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter Revision: 0 Laboratory Man ager/lqao/rso Date Date EffectiveDate: I ^, P /ru /,6 8-tt tt Renewal Date: lnitials: Texas

More information

2100TR Liquid Scintillation Counter

2100TR Liquid Scintillation Counter 2100TR Liquid Scintillation Counter Description The Tri-Carb 2100TR liquid scintillation counter is computer-controlled, bench top liquid scintillation analyzer for detecting small amounts of alpha, beta

More information

GUIDE TO LABORATORY SURVEYS. Introduction

GUIDE TO LABORATORY SURVEYS. Introduction APPENDIX - V GUIDE TO LABORATORY SURVEYS Introduction Routine laboratory surveys are an important part of the overall radiation safety program in a laboratory. Surveys provide a direct measure of the presence

More information

Making sense of Limits of Detection (with respect to Tritium analysis) James Thomson Meridian Biotechnologies Ltd.

Making sense of Limits of Detection (with respect to Tritium analysis) James Thomson Meridian Biotechnologies Ltd. Making sense of Limits of Detection (with respect to Tritium analysis) James Thomson Meridian Biotechnologies Ltd. The dilemma Customer commented that the background of Gold Star had increased and was

More information

MEASUREMENT: PART II

MEASUREMENT: PART II 1 MEASUREMENT: PART II Copyright: Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, 2013. INTRODUCTION Read and/or review Section 1.7 and Figure 7.5 in your textbook. The first part

More information

Microscale Acid-Base Titration

Microscale Acid-Base Titration Microscale Acid-Base Titration Experiment 36 A titration is a process used to determine the volume of a solution needed to react with a given amount of another substance. In this experiment, you will titrate

More information

Safe Operating Procedure

Safe Operating Procedure Safe Operating Procedure (Revised 4/08) HAZARDOUS/RADIOACTIVE MATERIAL COLLECTION PROCEDURES (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Most used

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Procedure Radioimmunoassay with I Department Location SOP Prepared By: Section 1: Purpose Radioimmunoassays are used for detecting the concentration of a specific antigen or

More information

Exercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION

Exercise 4-3. Titration of Weak Acids EXERCISE OBJECTIVE DISCUSSION OUTLINE. The 5% rule DISCUSSION Exercise 4-3 Titration of Weak Acids EXERCISE OBJECTIVE Titrate both a weak acid solution and a weak polyprotic acid solution with a strong base solution. Plot a graph using the titration data, analyze

More information

ON SITE SYSTEMS Chemical Safety Assistant

ON SITE SYSTEMS Chemical Safety Assistant ON SITE SYSTEMS Chemical Safety Assistant CS ASSISTANT WEB USERS MANUAL On Site Systems 23 N. Gore Ave. Suite 200 St. Louis, MO 63119 Phone 314-963-9934 Fax 314-963-9281 Table of Contents INTRODUCTION

More information

Lab 2 UW Radiation Safety Program

Lab 2 UW Radiation Safety Program Lab 2 UW Radiation Safety Program Objective To review procedures, records and forms used by research labs in following the UW's Radiation Safety Program (i.e., properly receiving, using, disposing, surveying,

More information

Safe Operating Procedure (Revised 4/08)

Safe Operating Procedure (Revised 4/08) Safe Operating Procedure (Revised 4/08) HAZARDOUS/RADIOACTIVE MATERIAL COLLECTION PROCEDURES (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Most used

More information

The measurement of tritium in environmental water samples

The measurement of tritium in environmental water samples The measurement of tritium in environmental water samples 1. Introduction The Hidex 300 SL automatic TDCR liquid scintillation provides an excellent solution for the determination of H-3 in drinking water.

More information

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0 Analyzing Radiation Introduction Radiation has always been a natural part of our environment. Radiation on earth comes from many natural sources; the origin of all types of naturally occurring radiation

More information

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP. NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION OFFICE OF QUALITY ASSURANCE ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM ON-SITE LABORATORY EVALUATION RADIOCHEMISTRY PROCEDURES Gross Alpha-Gross Beta

More information

TECHNETIUM-99 IN WATER

TECHNETIUM-99 IN WATER Analytical Procedure TECHNETIUM-99 IN WATER (TEVA DISC METHOD) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all aspects

More information

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY PURPOSE This procedure provides instructions for developing, maintaining, and documenting, radiation safety procedures conducted at the Cyclotron Radiochemistry

More information

TECHNETIUM-99 IN WATER

TECHNETIUM-99 IN WATER Analytical Procedure TECHNETIUM-99 IN WATER (WITH VACUUM BOX SYSTEM) 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in water. 1.2. This method does not address all

More information

SYRACUSE UNIVERSITY RADIATION PROTECTION PROGRAM APPLICATION FOR USE OF RADIOACTIVE MATERIALS

SYRACUSE UNIVERSITY RADIATION PROTECTION PROGRAM APPLICATION FOR USE OF RADIOACTIVE MATERIALS SYRACUSE UNIVERSITY RADIATION PROTECTION PROGRAM APPLICATION FOR USE OF RADIOACTIVE MATERIALS Please submit the completed application form and any attachments to the Environmental Health & Safety Services

More information

TECHNETIUM-99 IN SOIL

TECHNETIUM-99 IN SOIL Analytical Procedure TECHNETIUM-99 IN SOIL 1. SCOPE 1.1. This procedure describes a method to separate and measure technetium-99 in soil. 1.2. This method does not address all aspects of safety, quality

More information

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER 1 Name: Lab Instructor: PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER On these problems, the solvent is water and the solution is sufficiently dilute so that the density of the solution is the same

More information

Radioactive Waste Management Guide

Radioactive Waste Management Guide State University of New York at Stony Brook Radiation Protection Services Radioactive Waste Management Guide EHSD0247 (02/08) Page 1 of 12 www.stonybrook.edu/ehs Radiation Protection Services This document

More information

Acid-Base Titration. Sample

Acid-Base Titration. Sample Acid-Base Titration Computer 7 A titration is a process used to determine the volume of a solution that is needed to react with a given amount of another substance. In this experiment, your goal is to

More information

Using Conductivity to Find an Equivalence Point

Using Conductivity to Find an Equivalence Point Experiment 25 PRE LAB DISCUSSION In this experiment, you will monitor conductivity during the reaction between sulfuric acid, and barium hydroxide in order to determine the equivalence point. From this

More information

Scripps Institution of Oceanography University of California, San Diego

Scripps Institution of Oceanography University of California, San Diego Scripps Institution of Oceanography University of California, San Diego Training Goals To familiarize science parties with the unique circumstances associated with isotope use on research vessels. To educate

More information

COLUMBIA UNIVERSITY PERMIT APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIALS

COLUMBIA UNIVERSITY PERMIT APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIALS COLUMBIA UNIVERSITY PERMIT APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIALS This is an application for non-human (research) use of ionizing radiation and is required in order to receive a permit

More information

QAM-I-116 Preparation of Labware

QAM-I-116 Preparation of Labware 1. Applicability and Purpose i. This procedure applies to all labware (glassware and plasticware) used for analysis in the laboratory, and sampling bottles and equipment used in field sample operations.

More information

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority: Title: Chemical Hygiene Written Program Effective Date: November 2005 Revision Date: February 8, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 1

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 1 Page 1 of 6 Approvals: Preparer: Jason McMillan Reviewer: Dr. Maggie Bryans Date: 08JAN14 Date: 10JAN14 1. Purpose: To verify the calibration of a single channel pipette. 2. Scope: Covers the cleaning,

More information

PREP Course 13: Radiation Safety for Laboratory Research. William Robeson Radiology Service Line Physicist

PREP Course 13: Radiation Safety for Laboratory Research. William Robeson Radiology Service Line Physicist PREP Course 13: Radiation Safety for Laboratory Research William Robeson Radiology Service Line Physicist CME Disclosure Statement The North Shore LIJ Health System adheres to the ACCME s new Standards

More information

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter TCA-004 Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter Abstract Scintillation Proximity Assay (SPA) is a technique for performing binding assays without separation of bound

More information

Revised material in Section 4, Analytical Chemistry

Revised material in Section 4, Analytical Chemistry Revised material in Section 4, Analytical Chemistry Fe-01-RC: IRON IN AQUEOUS SAMPLES - DUAL-DPM MODE LIQUID SCINTILLATION ANALYSIS G-04: PREPARATION OF MICROPRECIPITATION SOURCES FOR REANALYSIS Fe-01-RC

More information

Microscale Acid-Base Titration

Microscale Acid-Base Titration icroscale Acid-Base Titration Experiment 31 A titration is a process used to determine the volume of a solution needed to react with a given amount of another substance. In this experiment, you will titrate

More information

THE UNIVERSITY OF NEWCASTLE SCHOOL of BIOMEDICAL SCIENCES

THE UNIVERSITY OF NEWCASTLE SCHOOL of BIOMEDICAL SCIENCES THE UNIVERSITY OF NEWCASTLE SCHOOL of BIOMEDICAL SCIENCES STANDARD OPERATING PROCEDURE PROCEDURE NO: BS-GDP 018 MOD: 3 rd Issue Page: 1 of 5 Procedure Type: General Discipline Procedure 1. Risk Assessment:

More information

VDL ENDOTOXIN ASSAY: ASSAY FOR LIMULUS AMEBOCYTE LYSATE

VDL ENDOTOXIN ASSAY: ASSAY FOR LIMULUS AMEBOCYTE LYSATE 1. Purpose 1.1. The purpose of this protocol is test purified viral vectors for endotoxin contamination. 1.2. This procedure is routinely performed in the Vector Development Laboratory (VDL) following

More information

Portable Radiation Survey Instruments

Portable Radiation Survey Instruments Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Portable Radiation Survey Instruments GUIDELINES FOR BASIC INSTRUMENT CARE Portable radiation survey instruments, often called

More information

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC)

Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC) Gross Alpha-Gross Beta Analysis in Water by Liquid Scintillation Counting (LSC) Bob Read, Ph.D. Director, Environmental Chemistry Laboratory Tennessee Department of Health Division of Laboratory Services

More information

January 2002 INSTRUMENT MANUAL 1470 WIZARD. Gamma Counter

January 2002 INSTRUMENT MANUAL 1470 WIZARD. Gamma Counter INSTRUMENT MANUAL 1470-931-23 January 2002 1470 WIZARD Gamma Counter Wallac 1470 WIZARD Gamma counter For instruments with software version 3.6 Wallac Oy, P.O. Box 10, FIN-20101 Turku, Finland. Tel: 358-2-2678111.

More information

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions Exercise 4-4 Titration of a Buffer Solution EXERCISE OBJECTIVE Titrate a buffer solution, plot a graph using the titration data, and analyze the titration curve. DISCUSSION OUTLINE The Discussion of this

More information

HAZARD COMMUNICATION SAFETY PROGRAM

HAZARD COMMUNICATION SAFETY PROGRAM Hazard Communication Program HAZARD COMMUNICATION SAFETY PROGRAM 1. Purpose. To provide an effective, written hazard communication program in compliance with company, State and Federal regulatory requirements.

More information

ACID-BASE TITRATION (MICROSCALE)

ACID-BASE TITRATION (MICROSCALE) ACID-BASE TITRATION (MICROSCALE) LAB PH 4.PALM From Science with Handhelds, Vernier Software & Technology, 2002. INTRODUCTION Acids and bases represent a major class of chemical substances. We encounter

More information

6 Acid Base Titration

6 Acid Base Titration E x p e r i m e n t Acid Base Titration Experiment : http://genchemlab.wordpress.com/-titration/ objectives To understand the concept of titration. To explain the difference between the analyte and standard

More information

Radioactive Waste Requirements

Radioactive Waste Requirements Radioactive Waste Requirements October 2013 Office of Environment, Health & Safety TABLE OF CONTENTS UC Berkeley,... 2 1.0 General Information, Requirements and Precautions... 3 1.1 Radioactive Waste Records/Request

More information

CHEMISTRY DEPARTMENT

CHEMISTRY DEPARTMENT POINT LEPREAU GENERATING STATION GADOLINIUM ARSENAZO III Issued By: Date: APPROVED BY: of 6 REVISION RECORD AUTHOR REV DESCRIPTION DATE 0 Initial Issue W. Mawhinney Not Tracked Oct./9 W. T. Underhill 2

More information

Acid-Base Titration. Evaluation copy

Acid-Base Titration. Evaluation copy Acid-Base Titration Computer 7 A titration is a process used to determine the volume of a solution that is needed to react with a given amount of another substance. In this experiment, your goal is to

More information

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

1. Preliminary qualitative analysis of unknown substances (liquid or solid). Name of Procedure: Ultraviolet Spectroscopy Suggested Uses: 1. Preliminary qualitative analysis of unknown substances (liquid or solid). 2. Quantitative analysis of known compounds. Apparatus Used to Perform

More information

Acid-Base Titration. Volume NaOH (ml) Figure 1

Acid-Base Titration. Volume NaOH (ml) Figure 1 LabQuest 24 A titration is a process used to determine the volume of a solution needed to react with a given amount of another substance. In this experiment, you will titrate hydrochloric acid solution,

More information

RESULTS YOU CAN COUNT ON

RESULTS YOU CAN COUNT ON RESULTS YOU CAN COUNT ON Liquid Scintillation Counting Principle and the Application in Biological Research 1 2009 PerkinElmer liquid scintillation counting β particle Tri-Carb family of liquid scintillation

More information

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE? POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE? POGIL LAB 15 Page 1 of 10 Each member should assume his or her role at this time. The new manager takes charge of the POGIL folder and hands

More information

Refresher Radiation Safety Training Scott Jaqua, RSO

Refresher Radiation Safety Training Scott Jaqua, RSO Refresher Radiation Safety Training Scott Jaqua, RSO 1 Section 1 Introduction 2 RSO Contact Information www.pdx.edu/environmental-health-safety Look for Research Safety Scott Jaqua, RSO 503-725-5269 phone

More information

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II) : Absorption Spectroscopy of Cobalt(II) OBJECTIVES In successfully completing this lab you will: prepare a stock solution using a volumetric flask; use a UV/Visible spectrometer to measure an absorption

More information

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base INTRODUCTION Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base Chemists frequently make use of the equivalent weight (eq. wt.) as the basis for volumetric calculations.

More information

Technology that counts

Technology that counts Application Note No. 102 Version 1.3 Determination of Sperm Density in Ejaculates from Bulls Application This Application Note describes how sperm cell density in ejaculates from bulls can be determined

More information

Instructor s Advance Preparation

Instructor s Advance Preparation INSTRUCTOR'S MANUAL Instructor s Advance Preparation This protocol is designed for 80 workstations of 4 students. Each group will prepare a set of standards, a blank, and 2 milk samples (can be a blind

More information

Technology that counts

Technology that counts Application Note No. 100 Version 1.3 Determination of Sperm Density in Ejaculates from Boars Application This Application Note describes how sperm cell density in ejaculates from boars can be determined

More information

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 0

Montgomery County Community College Document Number: MET DeKalb Pike Revision Number: 0 Page 1 of 5 Approvals: Preparer: Jason McMillan Reviewer: Dr. Maggie Bryans Date: 08JAN14 Date: 10JAN14 1. Purpose: Operation of Eppendorf Research Plus through to the P-1000. 2. Scope: Applies to the

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law The primary objective of this experiment is to determine the concentration of an unknown cobalt (II) chloride solution. You will use a Vernier SpectroVis

More information

Experimental Procedure Lab 402

Experimental Procedure Lab 402 Experimental Procedure Lab 402 Overview One set of solutions having known molar concentrations of FeNCS 2+ is prepared for a calibration curve, a plot of absorbance versus concentration. A second set of

More information

The LSC Approach to Radon Counting in Air and Water

The LSC Approach to Radon Counting in Air and Water CHAPTER 32 The LSC Approach to Radon Counting in Air and Water Charles J. Passo, Jr. and James M. Floeckher INTRODUCTION Various methods exist to monitor 222Rn in air. There are seven commonly used types

More information

Application for Radioactive Material Use

Application for Radioactive Material Use Application for Radioactive Material Use Instructions All Authorized Users (AU) must be approved and authorized by the Radiation Safety Committee prior to using Radioactive Materials. Additionally, requests

More information

PRELIMINARY ACTIVITY FOR

PRELIMINARY ACTIVITY FOR PRELIMINARY ACTIVITY FOR Beer s Law Investigations Guided Inquiry Version Experiment 11 The primary objective of this Preliminary Activity is to determine the concentration of an unknown copper (II) sulfate

More information

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter 1/5 Specification Hidex 300 SL-SLL 100-240V AC and 24 V DC. Features Model (425-020) Super Low Level (SLL) Automatic TDCR Liquid Scintillation Counter with Guard Detector and Low Level PMTs General Description

More information

TPH (Total Petroleum Hydrocarbons)

TPH (Total Petroleum Hydrocarbons) TPH (Total Petroleum Hydrocarbons) DOC316.53.01475 Immunoassay 1 Method 10050 Scope and application: For water. 1 This test is semi-quantitative. Results are shown as more or less than the threshold value

More information

Melatonin Research RIA

Melatonin Research RIA Instructions for use Melatonin Research RIA BA R-3900 Melatonin Research RIA 1. Intended use and principle of the test Radioimmunoassay for the quantitative determination of Melatonin in biological samples.

More information

Micro Volume QuEChERS kit

Micro Volume QuEChERS kit 225-37872 Sep. 2018 Small Capacity Pretreatment Kit Micro Volume QuEChERS kit Instruction Manual Read this manual thoroughly before you use the product. Keep this manual for future reference. This page

More information

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Standardizing a Solution of Sodium Hydroxide. Evaluation copy Standardizing a Solution of Sodium Hydroxide Computer 6 It is often necessary to test a solution of unknown concentration with a solution of a known, precise concentration. The process of determining the

More information

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis Technical Procedure for Solid Phase Extraction of THC and THC-COOH 1.0 Purpose - This procedure specifies the required elements for the extraction of THC and THC-COOH using United Technologies Styre Screen

More information

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1 Determining the Concentration of a Solution: Beer s Law Computer 17 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You will use a

More information

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples

Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Energy Calibration of Liquid Scintillation Counter to allow Semi-Qualitative Nuclide Identification in Water Samples Mashaba, Machel. 1*, Kotze, Deon. 2, Tshivhase, Victor.M. 1, Faanhof, Arnaud. 1, 2 1

More information

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS International Conference Nuclear Energy in Central Europe 2001 Hoteli Bernardin, Portorož, Slovenia, September 10-13, 2001 www: http://www.drustvo-js.si/port2001/ e-mail: PORT2001@ijs.si tel.:+ 386 1 588

More information

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA For the quantitative determination of pig VEGF-A in serum, plasma and other biological fluids. Cat. No. KT-32008 For Research Use Only. Not

More information

Liquid Scintillation Counter

Liquid Scintillation Counter Instrumentation & Methods: s & Tritium Richard Sheibley Pennsylvania Dept of Env Protection Principle Beta particle emission Energy transferred to Solute Energy released as UV Pulse Intensity proportional

More information

Liquid Scintillation at NPL: Practical Applications

Liquid Scintillation at NPL: Practical Applications 2003 LS User s Forum Liquid Scintillation at NPL: Practical Applications Andy Pearce CAIR, NPL 2 nd April 2003 Introduction Overview of applications Current projects Neutron-activated thioacetamide discs

More information

mylab: Chemical Safety Module Last Updated: January 19, 2018

mylab: Chemical Safety Module Last Updated: January 19, 2018 : Chemical Safety Module Contents Introduction... 1 Getting started... 1 Login... 1 Receiving Items from MMP Order... 3 Inventory... 4 Show me Chemicals where... 4 Items Received on... 5 All Items... 5

More information

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point. 93 experiment7 Determining an Unknown Concentration Understanding the concept of titration. LECTURE AND LAB SKILLS EMPHASIZED Explaining the difference between analyte and standard solutions. Know the

More information

Chemical Equilibrium: Finding a Constant, Kc

Chemical Equilibrium: Finding a Constant, Kc Chemical Equilibrium: Finding a Constant, Kc Experiment 20 The purpose of this lab is to experimentally determine the equilibrium constant, K c, for the following chemical reaction: Fe 3+ (aq) + SCN (aq)

More information

Rat Coagulation Factor V (F5) ELISA

Rat Coagulation Factor V (F5) ELISA Rat Coagulation Factor V (F5) ELISA For the quantitative determination of rat F5 in plasma Cat. No. KT-11028 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 7 Rev. 1295911028 INTENDED

More information

Mouse Platelet Factor 4 (PF4) ELISA

Mouse Platelet Factor 4 (PF4) ELISA Mouse Platelet Factor 4 (PF4) ELISA For the quantitative determination of mouse PF4 in plasma Cat. No. KT-25527 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 7 Rev. 2010-02-17

More information

Safe Method of Use 2 Workshop and Arts Studios

Safe Method of Use 2 Workshop and Arts Studios Safe Method of Use 2 Workshop and Arts Studios Purpose: This Safe Method of Use applies to principal investigators (PIs), sector managers, designated laboratory person (DLPs), technical staff and students

More information

Goldwater Environmental Lab Guidelines and Policies

Goldwater Environmental Lab Guidelines and Policies Goldwater Environmental Lab Guidelines and Policies (Rev G; December 20, 2007) Lab Manager: Tom Colella Web Site: http://www.asu.edu/gel e-mail: T.Colella@asu.edu *Instrument and Equipment Use Access is

More information

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated Teacher Information Ideal Gas Law Objectives Determine the number of moles of carbon dioxide gas generated during a reaction between hydrochloric acid and sodium bicarbonate. Through this investigation,

More information

Lab 5: Calculating an equilibrium constant

Lab 5: Calculating an equilibrium constant Chemistry 162 The following write-up is inaccurate for the particular chemicals we are using. Please have all sections up through and including the data tables ready before class on Wednesday, February

More information

RADIONUCLIDE INFORMATION

RADIONUCLIDE INFORMATION RADIONUCLIDE INFORMATION Below are some physical properties and practical handling information for radionuclides most commonly used in the research environment. Contact the RSO for additional information

More information

[Unless otherwise stated all tolerances are ±5%] SAMPLES

[Unless otherwise stated all tolerances are ±5%] SAMPLES PHOSPHATASE TEST - FLUOROPHOS ALP TEST SYSTEM IMS #28 [Unless otherwise stated all tolerances are ±5%] SAMPLES 1. Laboratory Requirements (see Cultural Procedures [CP] items 33 & 34) [See current version

More information

N) manual. Biomaster Operating manual

N) manual. Biomaster Operating manual 830 ual N) manual Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Trademarks Eppendorf and the

More information

Devyser Index Plate A. Instructions for Use

Devyser Index Plate A. Instructions for Use Devyser Index Plate A Art. No.: 8-A200 Instructions for Use Page 1 of 17 TABLE OF CONTENTS TABLE OF CONTENTS 2 1. INTRODUCTION TO DEVYSER INDEX PLATE A 3 1.1 Intended use 3 1.2 Kit configuration Devyser

More information

Rat Coagulation Factor X (F10) ELISA

Rat Coagulation Factor X (F10) ELISA Rat Coagulation Factor X (F10) ELISA For the quantitative determination of rat F10 in plasma Cat. No. KT-11067 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 7 Rev. 1057811067 Product

More information

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013 Absorbance Experiment 13 Dilutions and Data Handling in a Spreadsheet rev 1/2013 GOAL: This lab experiment will provide practice in making dilutions using pipets and introduce basic spreadsheet skills

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law LabQuest 11 The primary objective of this experiment is to determine the concentration of an unknown nickel (II) sulfate solution. You will be using

More information

REVIEW OF LAB TECHNIQUES

REVIEW OF LAB TECHNIQUES Experiment 1 REVIEW OF LAB TECHNIQUES Prepared by Masanobu M. Yamauchi and Ross S. Nord, Eastern Michigan University PURPOSE To review density calculations, Beer s Law and the use of electronic balances,

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law Vernier Spectrometer 1 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You

More information

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

DR/4000 PROCEDURE NITRATE. Using Powder Pillows DR/4000 PROCEDURE Method 8171 Powder Pillows or AccuVac Ampuls Cadmium Reduction Method MR (0 to 5.0 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit

More information

Conductimetric Titration and Gravimetric Determination of a Precipitate

Conductimetric Titration and Gravimetric Determination of a Precipitate Conductimetric Titration and Gravimetric Determination of a Precipitate LabQuest 16 In this experiment, you will monitor conductivity during the reaction between sulfuric acid, H 2 SO 4, and barium hydroxide,

More information

Simple Operation Manual

Simple Operation Manual 苦 SET UP Simple Operation Manual (1) Check the level of buffer, purified water and wash solution Left: Buffer Center: Wash solution Right: Purified water Change buffer or refill them (W.S. and P.W.) if

More information

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

Rat Selectin, Leukocyte (SELL) ELISA

Rat Selectin, Leukocyte (SELL) ELISA Rat Selectin, Leukocyte (SELL) ELISA For the quantitative determination of rat SELL in serum, plasma and other biological fluids Cat. No. KT-28055 For Research Use Only. Not for use in diagnostic procedures.

More information