OER implementation at UNS. Prof. Dr Ivana Ivančev-Tumbas University of Novi Sad, Faculty of Sciences

Size: px
Start display at page:

Download "OER implementation at UNS. Prof. Dr Ivana Ivančev-Tumbas University of Novi Sad, Faculty of Sciences"

Transcription

1 OER implementation at UNS Prof. Dr Ivana Ivančev-Tumbas University of Novi Sad, Faculty of Sciences

2 Overview 1. Planned development of OER 2. What do we need from EU partners? 3. Draft OER example

3 Overview 1. Planned development of OER 2. What do we need from EU partners? 3. Draft OER example

4 Faculty of Science Topic/level Matrix interferences in the flame atomic absorption spectrofotometry/phd (lab exercise) Method optimization for analysis anion by ion chromatography/phd (lab excercise) GC/MSmethod validation/phd (theoreticalexcercise) Controlcharts preparation for the method of analysis of total organic carbon /MSc(lab exercise) Validation of HPLC/DAD method/phd(lecture) Qualitative analysis using LC-DAD-MS/MS/PhD Topic/level LC-DAD-MS/MS operation /MSc (lab exercise) Removal of organic pollutants from water by means of advanced oxidation processes/msc(lecture) Photocatalyticdegradation of a biologically actives substance/phd (lecture) Isolation of selected natural product from plant material by semi-preparative HPLC Determination of preservatives and other additives in soft beverages by LC-DAD /MSc(lab exercise) Identification and quantification of secondary biomolecules in plant material by LC-DAD-MS/MS/PhD

5 Topic/level Engineered adsorption processes. Green and 'low-cost' technologies used in waste stream treatment/msc Instrumental analysis as a tool required for the quantification of residues of pollutants before and after the treatment of waste streams. Chromatography. Spectrophotometry/MSc Combined techniques (GC-MS, GC-MS/MS, HPLC-MS, HPLC-MS/MS, HPLC-TOF-MS/MS)/PhD, lecture and lab exercise Faculty of Technical Science Topic/level Groundwater monitoring: groundwater sampling technique, measuringofgroundwater level in wells (piezometers), instrumentation in groundwater monitoring, field measurements. Leachatemonitoring: leachatesampling technique, instrumentation in leachatemonitoring, field measurements/msc Sensors techniques in environmental monitoring programmes/msc

6 We have learned that the choices for OER delivery are wide Moodle Quiz based on bank of questions Lectures PPT and/or PREZI Cmaps

7 We still need to learn about sharing and copyrights!

8 Overview 1. Planned development of OER 2. What do we need from EU partners? 3. Draft OER example

9 MATCH of offer from EU partners and PC needs Topic EU Type Reminders in chemistry, kinetics and thermochemistryuseful for understanding the formation and dissociations of ions. Examples of applications in iii) environment Validation issues in bioanalysis Metabolomics principle and application Analysis of Protein post-translational modifications by mass spectrometry NMR video Methodsfor isolation of target analytes(spe, PSE, SPME, UAE, MAE etc.); methods of extracts clean-up and group fractionation (column chromatography, gel permeation chromatography); derivatizationfor GC analysis; GC-FID, GC-ECD, liquid chromatography with UV-VIS, Interpretation of EI and soft ionization mass spectra, comprehensive two-dimensional gas chromatography with mass spectrometric detection J.C-T. J.C-T. E.E/F.F. M.A J.C Real ex. Real ex. Videoof procedures Courses in professional insertion A.B. CPD? Proposal for joint CPD with UNS?

10 Overview 1. Planned development of OER 2. What do we need from EU partners? 3. Draft OER example

11 Environmental Quality Control (Advanced Course), PhD 1. GC/MS method validation, theoretical excercise, by I. Ivančev- Tumbas 2. Matrix interferences in the flame atomic absorption spectrofotometry by S. Maletić and I. Ivančev-Tumbas 3. Method optimization for analysis of anions by ion chromatography by S. Maletić, M. Watson and I. Ivančev-Tumbas

12 Example of GC/MS method validation (OER 1) Consists of several education elements: Entrance test with references and answers Concept map for Development of own Method validation plan Pictures Video-clips Word documents Real example test Are those parts separate elements?

13 Entrance test Before student can think of own method he/she has to have knowledge gained at previous levels of studies. To chek, repeat and prepare oneself he/she will do: Quiz with answers and direction to literature references To check understanding, application, analysis of the process in instrument This has to be done before start of the method development plan Will be on Moodle platform

14 Question data base has to be made for topics, appropriate for the highest level of education: 1. How GC works Parts Principle Retention times Columns Injectors (liners, septa, peak focusing) Detectors 2. How MS works EI, CI Data aquisition SIM, SCAN Data analysis- qualitative and quantitative analysis (IS, external standars, standard addition) Check is it working in a proper way 3. Sample prep Extraction Clean up

15 Examples of questions Instead of the question: What is the retention time? they will be asked to read and compare RT from real chromatograms. How is RT influenced by the temperature and or gas flow? they will be asked to explain why some changes in real chromatograms happen due to temperature and flow changes. To explain CI and EI they will be asked to gues which one type of ionisation is used to get certain spectra and how they can increase sensitivity of their instrument.... Thus we will encourage both analytical and synthetical way of thinking as well as evaluation before they get main task.

16

17

18 Concept map-synthesis of the knowledge

19 Concept map-doc, jpeg and clips will be added

20 12/8/2017 Meeting in Belgrade, 5th-8th December 2017

21 Real, problem based example-test on their own substance Evaluation of the developed method for benzophenone analysis in water Internal standard method, benzophenone d-5 Extraction by SPE procedure, OASIS HLB 60mg Evaporation to dryness and derivatisation with PFBHA The results of the testing method for benzophenone analysis are given in Test excell file with four sheets: Calibration, Blank LOD LOQ, Precision, Recovery.

22 Calibration Worksheet Calibration contains the surfaces of target ions peaks for benzophenone (BP), m/z 377 and IS, (BP-d 5 ), m/z 382. Calibration has been done 3 times for concentration levels of 20, 100, 200, 400, 750 and 1100 ng/l. Concentration of IS was 500 ng/l. Task: present your plan of making solutions if you want to do SPE with 200 ml of water. Task: Calculate average linear equation for calibration curve and coresponding coefficient of correlation.

23

24 LOD and LOQ In worksheet named Blank LODLOQ data for 7 measurements of blank samples (water matrix spiked with internal standard in same concentration as calibration standards) are given. Task: Calculate LOD and LOQ

25 Precision Instrument precision was checked by injecting calibration standard at 6th concentration level (1100 ng/l) three times from the same vial. Task: report on precision of those injections by analysing responses of the detector for target ion of BP Method precision was checked by analysing injections in triplicate for two different concentrations within calibration curve (e.g. At 200 and 750 ng/l level). Task: report on precision of those injections by analysing ratio of responses of the detector for target ion if BP and target ion of IS for triplicate measruerments at each concentration level

26

27 Recovery test flow Spiked clean water matrix and addition of IS SPE Collection into clean vial Evaporation to dryness Derivatisation Injectio n Clean water matrix SPE Collection into vial with added IS and compound in same quantity and dried before collection of extract Evaporation to dryness Derivatisation Injection Results of testing are presented in worksheet recovery. Task: calculate the values for recovery and elaborate are they satisfactory or not and why.

28 Example at low concentration ion RT RLW1 A/Ais RLW2 A/Ais RLW3 A/Ais RSPEL1 A/Ais RSPEL2 A/Ais RSPEL3 A/Ais BP Dbp ng/l RL1 RL2 RL3 RL4 RL5 RL6 RL7 RL8 RL9 av sd RSD % % RLW1/RSPEL1

29 By calculation of R value student will obtain erroneous results of 300% and 800% He or she has to conclude why is it so and to design the action to propose the action to solve the issue.

30 Recovery test flow Spiked clean water matrix and addition of IS SPE Collection into clean vial Evaporation to dryness Derivatisation Injectio n Clean water matrix SPE Collection into vial with added IS and compound in same quantity and dried before collection of extract Evaporation to dryness Derivatisation Injection

31 Thank you for the cooperation

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Application Note Environmental Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Authors Ye Kong and Zhe Cao Agilent Technologies,

More information

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB. Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction

More information

WADA Technical Document TD2003IDCR

WADA Technical Document TD2003IDCR IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must

More information

CHROMATOGRAPHY AND MASS SPECTROMETER

CHROMATOGRAPHY AND MASS SPECTROMETER 22 CHROMATOGRAPHY AND MASS SPECTROMETER 22.1 INTRODUCTION We know that the biochemistry or biological chemistry deals with the study of molecules present in organisms. These molecules are called as biomolecules

More information

Analytical Instrumentation

Analytical Instrumentation Gas Chromatography and Mass Spectrophotometry Environmental, food safety, toxicology, and forensic gas chromatography applications are more demanding than ever. Our portfolio of GC, GC- MS, GC-MS/MS and

More information

University of the Aegean

University of the Aegean University of the Aegean Department of Environmental Studies Water and Air Quality Laboratory Simultaneous determination of pharmaceutical compounds and endocrine disrupting chemicals (EDCs) in wastewater

More information

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary

More information

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017. Final Report Title Characterisation of Job No 2016/11/12-34 AS No. 1234A Client Contact Sample Author report Signed Date 2017 Easy Reach Report 2017 v2.docx 1 of 33 Contents 1. Study Summary Page 3 2.

More information

Choosing Fit-For-Purpose Food Safety Methods

Choosing Fit-For-Purpose Food Safety Methods Choosing Fit-For-Purpose Food Safety Methods Outline Method selection Screening & quantification methods Extraction, cleanup and chromatography Detection methods Method criteria validation Conclusions

More information

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3) Schedule Assignment Due Date Draft Section of Lab Report Monday 6pm (Jan 27) Quiz for Lab 2 Peer Review of Draft Complete Lab Report 1 Tuesday 9:30am Wednesday 6pm Friday 6pm Summary of Paper 2 Monday

More information

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins TECHNICAL NOTE 39 A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins Author Cristian Cojocariu Thermo Fisher Scientific, Runcorn,

More information

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada) Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Introduction to Pharmaceutical Chemical Analysis

Introduction to Pharmaceutical Chemical Analysis Introduction to Pharmaceutical Chemical Analysis Hansen, Steen ISBN-13: 9780470661222 Table of Contents Preface xv 1 Introduction to Pharmaceutical Analysis 1 1.1 Applications and Definitions 1 1.2 The

More information

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL CAC/GL 56-2005 Page 1 of 6 GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CONFIRMATORY TESTS CAC/GL 56-2005 When analyses are

More information

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote 1 April 2015 European Union s CODEX COMMITTEE ON PESTICIDE RESIDUES 47 th Session Beijing, China, 13 18 April 2015 AGENDA ITEM 8 PROPOSED DRAFT GUIDELINES ON PERFORMANCE CRITERIA SPECIFIC FOR METHODS OF

More information

Rosemary extract liquid

Rosemary extract liquid EUROPEAN COMMISSION DIRECTORATE-GENERAL JOINT RESEARCH CENTRE Institute for Reference Materials and Measurements Community Reference Laboratory - Feed Additives Authorisation Evaluation Report of the Community

More information

LC-MS Based Metabolomics

LC-MS Based Metabolomics LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile

More information

WP 1.3. Presentation of this deliverable

WP 1.3. Presentation of this deliverable WP 1.3. Presentation of this deliverable Tatjana Anđelković University of Nis Faculty of Science and Mathematics ICT Networking for Overcoming Technical and Social Barriers in Instrumental Analytical Chemistry

More information

Luminescence transitions. Fluorescence spectroscopy

Luminescence transitions. Fluorescence spectroscopy Luminescence transitions Fluorescence spectroscopy Advantages: High sensitivity (single molecule detection!) Measuring increment in signal against a dark (zero) background Emission is proportional to excitation

More information

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection APPLICATION NOTE 72686 Determination of underivatized aflatoxins,, G2, and in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection Authors Sylvia Grosse, Mauro De Pra, Frank

More information

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT Determination of Ethylene Oxide (ETO) in Mainstream Cigarette Smoke Using Hydrobromic Acid Derivatization and Gas Chromatography-Mass Spectrometry Method Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

More information

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Application Note: 56 Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Yang Shi, Catherine Lafontaine, Matthew Berube, John Fink, François Espourteille Thermo

More information

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages Daniela Held, PSS Polymer Standards Service GmbH, Mainz, Germany Gel permeation chromatography/size-exclusion chromatography (GPC/SEC)

More information

Training Courses. Chromatography training from the Crawford Scientific experts

Training Courses. Chromatography training from the Crawford Scientific experts Training Courses Chromatography training from the Crawford Scientific experts HPLC Fundamentals This one-day course introduces the fundamentally important concepts associated with HPLC analysis including

More information

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Method of determination of phtalates in spirituous beverages by gaschromatography/mass OIV-MA-BS-33 Method of determination of phtalates in spirituous beverages by gas-chromatography/mass Type IV method 1. SCOPE OF APPLICATION This method applies to the detection and assay of some phthalates

More information

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis Keywords: Automated GX-271 GPC Clean-up System, Contaminants,

More information

MS-based proteomics to investigate proteins and their modifications

MS-based proteomics to investigate proteins and their modifications MS-based proteomics to investigate proteins and their modifications Francis Impens VIB Proteomics Core October th 217 Overview Mass spectrometry-based proteomics: general workflow Identification of protein

More information

Determination of Volatile Substances Proof of Food Adulteration

Determination of Volatile Substances Proof of Food Adulteration ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of Volatile Substances Proof of Food Adulteration (method: gas chromatography with mass spectrometric detection) Exercise guarantor:

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

GC/MS Application Note

GC/MS Application Note GC/MS Application Note Determination of Odor Compounds in Water by SPME Arrow Gas Chromatography/Mass Spectrometry www.palsystem.com Determination of Odor Compounds in Water by SPME Arrow Gas Chromatography/Mass

More information

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW Pablo Gago-Ferrero Laboratory of Analytical Chemistry Department of Chemistry

More information

METHOD 3600B CLEANUP

METHOD 3600B CLEANUP METHOD 3600B CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks bjective: The purpose of this experiment is to quantify the caffeine content of a diet soda sample using Ultra-High Performance

More information

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID Asian Journal of Chemistry Vol. 21, No. 3 (2009), 1739-1746 Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID PRAVEEN KUMAR BALIYAN*, R.P.

More information

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Shijun Lua, Buu N. Trana, Jamie L. Nelsenb, Kenneth M. Aldousa. Journal of Chromatography

More information

Contaminant profiling: A set of next generation analytical tools to deal with contaminant complexity

Contaminant profiling: A set of next generation analytical tools to deal with contaminant complexity Contaminant profiling: A set of next generation analytical tools to deal with contaminant complexity Associate Professor Jan H Christensen Department of Basic Sciences and Environment Slide 1 Risk Assessment

More information

3590/ Laboratory

3590/ Laboratory 3590/3550 - Laboratory Time: Monday to Thursday 2:30 5:30 Location: 318 Parker Bldg. Five two week labs must be completed. Two students per experiment. Individual lab reports, sharing same data. There

More information

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure. High performance liquid chromatography (HPLC) is a much more sensitive and useful technique than paper and thin layer chromatography. The instrument used for HPLC is called a high performance liquid chromatograph.

More information

Counterfeit and illegal pesticides: Strategies for addressing the issue in the analytical laboratory

Counterfeit and illegal pesticides: Strategies for addressing the issue in the analytical laboratory Counterfeit and illegal pesticides: Strategies for addressing the issue in the analytical laboratory Dr Helen Karasali Benaki Phytopathological Institute Head of the NATIONAL LABORATORY of Chemical Control

More information

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Available online  Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(6):3275-3279 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Development and validation of a matrix solid-phase

More information

Introduction to Chromatography

Introduction to Chromatography Introduction to Chromatography Dr. Sana Mustafa Assistant Professor Department of Chemistry, Federal Urdu University of Arts, Science & Technology, Karachi. What is Chromatography? Derived from the Greek

More information

HPLC Praktikum Skript

HPLC Praktikum Skript HPLC Praktikum Skript Assistants: Gianluca Bartolomeo HCI D330, 3 46 68, bartolomeo@org.chem.ethz.ch Sahar Ghiasikhou HCI E330, 2 29 29, ghiasikhou@org.chem.ethz.ch 1. Introduction In chromatographic techniques,

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective

Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective SHULAMIT LEVIN HPLC in Pharmaceutics Σ Stability Indicating Methods Extra

More information

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded

More information

BUTYL ALCOHOL in urine by GC-FID Code GC05510

BUTYL ALCOHOL in urine by GC-FID Code GC05510 BUTYL ALCOHOL in urine by GC-FID Code GC00 BIOCHEMISTRY Butanol (or n-butyl alcohol) is an alcohol which at room temperature is presented as a colorless liquid smelling of alcohol. It is an inflammatory

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

CHMC 16 Instrumental Analysis (Syllabus)

CHMC 16 Instrumental Analysis (Syllabus) CHMC 16 Instrumental Analysis (Syllabus) Course Description CHMC16 is a laboratory course designed to compliment CHMC11 (Principles of Analytical Instrumentation). This course will provide a practical

More information

Introduction. Chapter 1. Learning Objectives

Introduction. Chapter 1. Learning Objectives Chapter 1 Introduction Learning Objectives To understand the need to interface liquid chromatography and mass spectrometry. To understand the requirements of an interface between liquid chromatography

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 18 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from

More information

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 2015 Content: Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of

More information

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2), ISSN: 0973-4945; CODEN ECJHAO E-Journal of Chemistry http://www.e-journals.net 2010, 7(2), 629-635 Low-level Determination of Residual Methyl Methane Sulfonate and Ethyl Methane Sulfonate in Pharmaceuticals

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

Validation of an Analytical Method

Validation of an Analytical Method Validation of an Analytical Method Refer to: ICH Guideline Q2(R1), Validation of Analytical Procedures: Teaxt andmethodology. Introduction All major laboratories eg. in the industry operates with clearly

More information

Agilent MassHunter Quantitative Data Analysis

Agilent MassHunter Quantitative Data Analysis Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis

More information

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 1 Supporting Information 2 3 Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 4 5 John Moreman, Okhyun

More information

U.S. EPA Method 8270 for multicomponent analyte determination

U.S. EPA Method 8270 for multicomponent analyte determination ENVIRONMENTAL application note U.S. EPA Method 8270 for multicomponent analyte determination Elaine A. LeMoine and Herman Hoberecht Introduction Multicomponent analytes are compounds that yield several

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis An Executive Summary Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis Kerstin Krätschmer European Union Reference Laboratory for Dioxins and PCBs in Feed

More information

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997 Appendix A Glossary of Definitions, Acronyms, Abbreviations and Symbols March 1997 Glossary Of Definitions, Acronyms, Abbreviations And Symbols 1.0 Standard Acronyms, Abbreviations, And Symbols 1.1 Units

More information

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS Lee Goodwin Sample Preparation Chromatography Detection General Strategies Examples New Approaches Summary Outline ABUNDANCE

More information

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System Bertram ieland 1 and Stephen Lock 2 1 AB SCIEX ieuwerkerk aan den Ijssel, The etherlands;

More information

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5 Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH 5730-6730 Analysis Topic 5 Chromatography! Group of separation techniques based on partitioning (mobile phase/stationary phase). Two immiscible

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Making Sense of Differences in LCMS Data: Integrated Tools

Making Sense of Differences in LCMS Data: Integrated Tools Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From

More information

Physical Separations and Chromatography

Physical Separations and Chromatography Lab #5A & B: Physical Separations and Chromatography Individual Objectives: At the end of these experiments you should be able to: Ø Distinguish between Rf and tr; chromatograph and chromatogram; adsorption

More information

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY (GC) GAS CHROMATOGRAPHY (GC) Pre-Lab Questions Questions are to be answered before the beginning of the laboratory. The answers are due at the beginning of each experiment (the questions are for credit and

More information

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan. Determination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection Sadao Nakamura,* Takashi Yamagami and Shigeki

More information

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 66 Triple Quadrupole LC/MS System Application Note Environmental Authors Don Noot, Matthew Noestheden, and Ralph Hindle Vogon

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 126 Infinity Binary LC system with UV detection Application Note Food Author Srividya Kailasam Agilent Technologies,

More information

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic Analysis of pesticide residues using various GC/MS systems Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic OUTLINE Czech Agriculture and Food Inspection Authority (CAFIA)

More information

WADA Technical Document TD2015IDCR

WADA Technical Document TD2015IDCR MINIMUM CRITERIA FOR CHROMATOGRAPHIC-MASS SPECTROMETRIC CONFIRMATION OF THE IDENTITY OF ANALYTES FOR DOPING CONTROL PURPOSES. The ability of a method to identify an analyte is a function of the entire

More information

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS PAGE: 1 of 18 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),

More information

CHEMISTRY. CHEM 0100 PREPARATION FOR GENERAL CHEMISTRY 3 cr. CHEM 0110 GENERAL CHEMISTRY 1 4 cr. CHEM 0120 GENERAL CHEMISTRY 2 4 cr.

CHEMISTRY. CHEM 0100 PREPARATION FOR GENERAL CHEMISTRY 3 cr. CHEM 0110 GENERAL CHEMISTRY 1 4 cr. CHEM 0120 GENERAL CHEMISTRY 2 4 cr. CHEMISTRY CHEM 0100 PREPARATION FOR GENERAL CHEMISTRY 3 cr. Designed for those students who intend to take chemistry 0110 and 0120, but whose science and mathematical backgrounds are judged by their advisors

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Electronic Supplementary Information. The selective response of templated polymer for the cationic drug

Electronic Supplementary Information. The selective response of templated polymer for the cationic drug Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2017 Electronic Supplementary Information The selective response of templated polymer for the cationic

More information

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay... Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials (HPLC grade)... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation...

More information

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Sensitive Detection of 2-MIB and Geosmin in Drinking Water Sensitive Detection of -MIB and Geosmin in Drinking Water Application Note Environmental Author Yean-Woong You Agilent Technologies, Inc. Seoul, Korea Abstract An automated SPME extraction method for easy

More information

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES Sys Stybe JOHANSEN, Soren FELBY Department of Forensic Chemistry, Institute of Forensic Medicine, University of

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 12 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

METHOD 3600C CLEANUP

METHOD 3600C CLEANUP METHOD 3600C CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3600 provides general guidance on selection of cleanup methods that are appropriate for the target analytes of interest. Cleanup methods are applied

More information

Chapter 27: Gas Chromatography

Chapter 27: Gas Chromatography Chapter 27: Gas Chromatography Gas Chromatography Mobile phase (carrier gas): gas (He, N 2, H 2 ) - do not interact with analytes - only transport the analyte through the column Analyte: volatile liquid

More information

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003 HPLC GRATE Chromatography Lab Course Dr. Johannes Ranke Organisation The groups Start at 9:00 am End at 18:00 pm at the latest Friday, 19th we will finish at 2:00 pm Thursday, 11th: Lecture at 08:15 am

More information

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids Calidus Pharma&Biotech Palarus System Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids Jonathan Blackwell, Eric Wise Lonza Derrick

More information

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

2010 Waters Corporation. Xevo TQ-S for Bioanalysis Xevo TQ-S for Bioanalysis Key innovations High Performance Stepwave RADAR Scan Wave Versatility Ion Sources Simplicity of Operation Engineered Simplicity The Xevo TQ family Built on the same foundations

More information

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs) Stir Bar Sorptive Extraction Analysis of PAHs in Aqueous Solution: Using a polymer based technique to pre-concentrate polyaromatic hydrocarbons for analysis by GC-MS. Background: Polyaromatic hydrocarbons

More information

DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING SRM NAGAR, KATTANKULATHUR-603203 EI 2302 ANALYTICAL INSTRUMENTS QUESTION BANK UNIT I COLORIMETRY AND SPECTROPHOTOMETRY Part A 1. State Lambert

More information

Benzoylecgonine in Urine by SAMHSA GC/MS

Benzoylecgonine in Urine by SAMHSA GC/MS application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Benzoylecgonine in Urine by SAMHSA GC/MS Introduction The United States Department

More information

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT Peter Hancock 1, Mike Hetmanski 2 and Richard J. Fussell 2 1 Waters Corporation, Atlas Park, Simonsway, Manchester M22 5PP, UK 2 Central

More information

Introduction to LC-MS

Introduction to LC-MS Wednesday April 5, 2017 10am Introduction to LC-MS Amy Patton, MS Laboratory Manager, Pinpoint Testing, LLC Little Rock, AR DESCRIPTION: Amy Patton, laboratory manager for Pinpoint Testing, will begin

More information

CHAPTER 6 GAS CHROMATOGRAPHY

CHAPTER 6 GAS CHROMATOGRAPHY CHAPTER 6 GAS CHROMATOGRAPHY Expected Outcomes Explain the principles of gas chromatography Able to state the function of each components of GC instrumentation Able to state the applications of GC 6.1

More information

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis An Executive Summary Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis The Exactive GC Orbitrap MS system can offer the specificity and sensitivity missing from

More information