HPLC Determination of Antidepressants and their Metabolites in Plasma
|
|
- Kathlyn Willis
- 5 years ago
- Views:
Transcription
1 HPLC Determination of Antidepressants and their Metabolites in Plasma <XQJ)RQJ&KHQJ, Laura Bean, Edouard S. P. Bouvier, Mark Capparella, Pamela Iraneta, Andy Jarrell, Uwe D. eue, Dorothy J. Phillips, and Doug Wittmer Waters Corporation, 34 Maple Street, Milford, MA 01757
2 Abstract Using the one-dimensional SPE method, we were able to obtain very high recoveries (all greater than 86%) and excellent reproducibility (all less than 5.0%) for a wide range of drugs. These compounds included acids, neutrals, and bases Using the two-dimensional SPE method, we were able to selectively isolate analytes of interest from a complex sample matrix while eliminating almost all interferences.
3 asis HLB Sorbent Hydrophilic-Lipophilic Balanced Hydrophilic monomer Lipophilic monomer water loving Provides the correct wetting property to keep the surface of the packing solvated even when the cartridges run dry fat loving Provides reversed-phase property for analyte retention Two Unique Properties Are Carefully Balanced Reference: "A ovel Polymeric Reversed-Phase Sorbent for Solid-Phase Extraction," LC GC Int. 10 (9) E.S.P. Bouvier, D.M. Martin, P.C. Iraneta, M. Capparella, Y. Cheng, and D.J. Phillips
4 3HUFHQW UHFRYHU\ Drying Effect on Recovery: C 18 C 18 (1cc/100mg) vs. asis HLB Cartridges 'U\LQJ 7LPH PLQXWHV HLB (1cc/30mg) 'U\LQJ 7LPH PLQXWHV * o Impact of Sorbent Drying * o Silanol Interaction * o Breakthrough of Polar Analyte Bouvier, Capparella 3URFDLQDPLGH $FHWDPLQRSKHQ 5DQLWLGLQH 3URSUDQRR 'R[HSLQ
5 ne-dimensional SPE Method Prepare Sample Solution Simple, Rugged, and Highly Reproducible ne General SPE Method for a Wide Range of Compounds Condition/Equilibrate 1 ml methanol/1 ml water Load 1 ml spiked sample Wash 1 ml 5% methanol in water Elute 1 ml methanol Evaporate and Reconstitute
6 Base CHCH 2 CH 2 (CH 3 )H CHCH 2 CH 2 (CH 3 ) 2 ordoxepin Doxepin ortriptyline CHCH 2 CH 2 HCH 3 CHCH 2 CH 2 (CH 3 ) 2 Amitriptyline Acid and Base H 2 S H CH 3 H 3 C H 3 C CH 3 H 2 H 2 H 2 S CH 3 Sulfamethoxazole Trimethoprim Sulfmerazine Chlordiazepxide and Metabolites Cl H 2 Cl H H Cl H Cl HCH 3 Cl H orchlordiazepoxide xazepam Desmethyldiazepam (ordiazepam) Chlordiazepoxide Demoxepam Cocaine and Metabolites CH 3 CH CH 3 CH 3 CH 3 CH 3 Cheng Benzoylecgonine Cocaine Cocaethylene
7 Bases: Tricyclic Antidepressants Compound Concentration % Recovery % RSD ortriptyline 0.5 µg/ml Doxepin 0.5 µg/ml Amitriptyline 1.0 µg/ml AU Column: Symmetry C18, 5 µm, 3.9 x 150 mm Temperature: 35 C Mobile Phase: 20 mm Phosphate ph 7: Methanol (30:70) Detection: UV at 254 nm Flow Rate: 1.0 ml/min. Injection Volume: 20 µl Sample Identification: Peak 1: ordoxepin (I.S.) Peak 2: ortriptyline Peak 3: Doxepin Peak 4: Amitriptyline Cheng Minutes
8 Results from the ne-dimensional SPE Method Using the one-dimensional SPE method, we were able to obtain excellent results for a wide range of compounds (concentration ranging between 40 ng/ml and 4.0 µg/ml) from a serum matrix: Recoveries all greater than 86% Reproducibility all less than 5.0%
9 Two-Dimensional SPE Method Prepare Sample Solution Condition/Equilibrate 1 ml methanol/1 ml water Load 1 ml spiked sample solution Acids Wash 1 ml 5% methanol in water Bases Wash acid in methanol/water Wash base in methanol/water Elute base in methanol/water Elute acid in methanol/water
10 Determination of % MeH in 2-D SPE Method: Wash-Elute Study Prepare Analytes in Saline Condition/Equilibrate 20 Cartridges/Wells 1 ml methanol/1 ml water Load 1 ml spiked saline solution 10 cartridges/wells 10 cartridges/wells Elute base in various % methanol in water e.g. 2% H4H Elute acid in various % methanol in water e.g. 2% HAc
11 Wash-Elute Study (Antidepressants): Area (uv * sec) Wash (base) Area (uv * sec) Cheng % MeH Elute (acid) % MeH ordoxepin ortriptyline Verapamil, nor- Methyl Doxepin Amitriptyline Verapamil Verapamil, Methoxy
12 Comparison of SPE Methods: heng Antidepressants in Plasma AU Min AU Min. 6 ne-dimensional 7 7 Sample Blank Two-Dimensional Sample Blank Column: Symmetry RP8, 5 µm 3.9 x 150 mm Temperature: 30 C Mobile Phase: 100 mm Phosphate ph acetonitrile:methanol (55:35:10) Detection: UV at 230 nm Flow Rate: 1.0 ml/min. Injection Volume: 50 µl Sample Identification: Peak 1: ordoxepin Peak 2: ortriptyline Peak 3: orverapamil Peak 4: Doxepin Peak 5: Amitriptyline Peak 6: Verapamil Peak 7: Methoxyverapamil (I.S.)
13 Results: Antidepressants Compound 2-Dimensional 1-Dimensional Concentration [µg/ml] Recovery (%) RSD (%) (n=6) Recovery (%) RSD (n=3) Amitriptyline Doxepin ordoxepin ortriptyline Verapamil orverapamil Cheng
14 asis HLB Extraction Plates and Cartridges
15 asis 96-Well Extraction Plate for High Throughput Analysis: Trazodone and Metabolite Cheng H 1-(3-Chlorophenyl)piperazine dihydrochloride Trazodone Cl Cl Prepare Sample 1 ml spiked porcine serum Condition and equilibrate 1 ml methanol and 1 ml water Load Sample Wash 1 ml 40% methanol containing 2% ammonium hydroxide Elute 500 µl 80% methanol containing 2% acetic acid Add 500 µl 2% ammonium hydroxide
16 Results from asis 96-Well Extraction Plate and asis Extraction Cartridges 0.01 AU standard 0 sample blank Cheng minute 2 3 Recoveries all greater than 88% Reproducibility all less than 5.6% Column: Symmetry RP8, 5 µm, 3.9 x 150 mm Temperature: 30 C Mobile Phase: 50 mm Phosphate ph 7: :methanol (36:64) Detection: Flow Rate: UV at 250 nm 1.0 ml/min. Injection Volume: 25 µl Peak 1: 1-(3-chlorophenyl)peperazine Peak 2: Maprotiline (I.S.) Peak 3: Trazodone
17 Low Elution Volume Waters Proprietary* Two-Stage Well Design single mold smaller lower stage for low bed masses larger upper stage for high bed masses current bed configuration maintained 10 mg 30 mg 60 mg * patent pending
18 Low Elution Volume Test Mixture: Acids, eutrals, and Bases (Arranged from Most to Least Polar) H H Acetaminophen S Ranitidine H H CH 2 H 2 H Procainamide CH 3 CH 3 H H H H H F Betamethasone Propranolol Dipropyl Phthalate CHCH 2 CH 2 (CH 3 ) 2 H H C(CH 2 ) 3 CH 3 F Doxepin Betamethasone Valerate
19 Waters 10 mg Extraction Plate: % RSDs in 150 µl Elution Volume n = 8 wells 3M C18-SD Waters 10 mg Plate Procainamide Ranitidine Acetaminophen Theophylline Betamethasone Propranolol Dipropyl phth. Doxepin B-meth Val
20 High Sensitivity Dectection Enalapril and Enalaprilat in Human Plasma (BLAKS) Enalapril Enalapril -d5 (IS) Enalaprilat test Enalaprilat -d5 (IS) PPD Pharmaco
21 High Sensitivity Dectection Enalapril and Enalaprilat in Human Plasma 0.25 ng/ml Enalapril test 5 ng/ml Enalapril -d5 (IS) 0.25 ng/ml Enalaprilat 5 ng/ml Enalaprilat -d5 (IS) PPD Pharmaco
22 Validated Method for Analysis of Enalapril in Human Plasma Concentration % Recovery n=6 Interday Precision, %CV n= 5 (x 2) Intraday Precision %CV n=6 0.5 ng/ml ng/ml ng/ml Internal Std PPD Pharmaco
23 Validated Method for Analysis of Enalaprilat in Human Plasma Concentration % Recovery n=6 Interday Precision, %CV n= 5 (x 2) Intraday Precision %CV n=6 0.5 ng/ml ng/ml ng/ml Internal Std PPD Pharmaco
24 Summary Unique Sorbent o impact of drying o silanols Extended ph range Universal sorbent Fast and Easy Method Development ne-dimensional method Simple method ne method, ne result Two-dimensional method Straightforward method Cleaner extracts
The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction
The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction Edouard S. P. Bouvier, Randy E. Meirowitz and Uwe D. Neue Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented
More informationA Unique, New, Multipurpose Sorbent Engineered for Reversed-Phase SPE
Poster #151 ISC '96 21st International Symposium on Chromatography, Stuttgart, September 15th-20th, 1996 1 A Unique, ew, Multipurpose Sorbent Engineered for Reversed-Phase SPE Authors 2 McDonald, P.D.*,
More information[ Care and Use Manual ]
Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic
More informationYuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB
Use of An Improved Version of C8+SCX Mixed-Mode Solid Phase Extraction Material for Clean Extraction and Recovery of Basic, Zwitterionic, Neutral and Acidic Compounds from Biological Fluids Yuhui Yang,
More informationFractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)
Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX) Application Note Forensic Toxicology Authors Bellah. Pule,
More informationEVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples
TN143 EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples This Chemistry Data Sheet provides guidelines for the extraction of quaternary
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationGemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationA New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS
A ew Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS M. Cleeve, L. Williams, A. owells, G. Davies, S. Merriman, S. Plant,. Gooding, J. Labadie, R. Johnston, M. Burke 1, R.
More informationImproved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18
Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18 Column Xin Zhang, Jonathan P. Danaceau, and Erin E. Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Semi-validated
More informationCHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data
Introduction The enrichment of hydrophilic analytes from polar matrices is a challenge because they often cannot be retained by C 18 / C 8 -modified silica or hydrophobic polymer adsorbents. To overcome
More informationFast and Easy Solid-Phase Extraction with a New Reversed-Phase Sorbent
Volume VI Issue 4, 997 Fast and Easy Solid-Phase Extraction with a New Reversed-Phase Sorbent Dorothy J. Phillips, Laura L. Bean, Edouard S.P. Bouvier, Mark Capparella, Yung-Fong Cheng, Pamela C. Iraneta
More informationAn Improved Method for HPLC Determination of Acidic Herbicides in Aqueous Samples
Volume VI Issue 5, 1997 An Improved Method for HPLC Determination of Acidic Herbicides in Aqueous Samples Michael S. Young, Waters Corporation solvent suitable for multiple analyses. Moreover, such an
More informationUltrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System
Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Authors Mohamed Youssef and Vaughn P. Miller Agilent
More informationOBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS
1997 Waters Corporation p. 1 980947 OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS T. Walter, P. Iraneta, and M. Capparella Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented
More informationJonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS
Rapid and Simultaneous Analysis of Urinary Catecholamines and Metanephrines Using Mixed-Mode SPE and Hydrophilic Interaction Chromatography (HILIC) for Clinical Research Jonathan P. Danaceau, Erin E. Chambers,
More informationcolumn If you would like a subscription, or more information, please contact your nearest Waters Office.
column Waters A Reprint from Spring 99 If you would like a subscription, or more information, please contact your nearest Waters Office. Check the Waters website for up-to-date information: http://www.waters.com
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationSimultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method
IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method Dr.R.Srinivasan*, K.Lurdhu
More informationSolid Phase Extraction Method Development Tips and Tricks
Solid Phase Extraction Method Development Tips and Tricks Carol Haney Ball, Ph.D. Application Scientist Agilent Technologies, Inc. February 3, 2009 Sources of Error Generated and Time Spent During a Typical
More informationA New Water-Wettable Solid Phase Extraction Sorbent for the Analysis of Drugs in Biological Fluids
Volume VI Issue 3, 1996 A New Water-Wettable Solid Phase Extraction Sorbent for the Analysis of Drugs in Biological Fluids Edouard Bouvier, Donna Martin, Pamela Iraneta, Mark Capparella, Dorothy Phillips,
More informationDilution(*) Chromatography
WA20264 Poster # 184, HPLC 2002, Montreal, 4-5 June 2002 At-Column Column-Dilution for Preparative Dilution(*) Chromatography Cecilia Mazza, Jie Cavanaugh, Ziling Lu,Tom Sirard,Tom Wheat and Uwe Neue Waters
More informationCharacterization of Carbon SPE for the Extraction of Polar Analytes
Characterization of Carbon SPE for the Extraction of Polar Analytes Cory Szafranski, Lydia Nolan, and William R. Betz Supelco, Supelco Park, Bellefonte, PA 16823 USA 1997 Sigma-Aldrich Co. T497277 BNG
More informationDevelopment of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices
Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices From sample preparation to LC/MS/MS Linda Côté Christophe Deckers Agilent Technologies
More informationDevelopment for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009
Advances in Method Development for SPE Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009 Welcome Goals Review the basics of solid-phase extraction (SPE) Discuss the elements
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationEnsure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications
Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Agilent Bond Elut Plexa vs. Waters Oasis Sample Prep Products Reliability is a key parameter in developing rugged,
More informationCHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)
CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC A UV spectrophotometric method based on the measurement of absorbance at 276nm in phosphate buffer of p H 7.4 was used in the present study of the
More informationApplication Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors
Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food
More informationFast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma
Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,
More informationHypersil BDS Columns TG 01-05
TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide
More informationStreamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System
Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System Margaret Maziarz, Sean M. McCarthy, Michael D. Jones, and Warren B. Potts Waters Corporation, Milford, MA, USA A P
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationMacrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)
More informationExtraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis
Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation
More informationDetection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.
Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC. Abstract Chetna Mittal, PhD, Asha Oroskar, PhD,, Anil Oroskar, PhD Orochem Technologies Inc. Lombard, IL,
More informationExtraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis
Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range
More informationSAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120
SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 Application Note Forensic Toxicology Authors Irina ioumaeva, John M. Hughes Agilent
More informationANALYSIS OF BASIC COMPOUNDS
COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare
More informationMaximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System
Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationAnalysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research
Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Heather A Brown, 1 Claudia Rossi, 2 and Lisa J Calton 1 1 Waters Corporation, Wilmslow, UK 2
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationScaling Up to Preparative Chromatography
Scaling Up to Preparative Chromatography Dr. Shulamit Levin home page: www.forumsci.co.il/hplc Strategy for Preparative Separation Selection of the appropriate mode of chromatography ptimization of the
More informationImpact factor: 3.958/ICV: 4.10 ISSN:
Impact factor: 3.958/ICV: 4.10 ISSN: 0976-7908 99 Pharma Science Monitor 9(4), Oct-Dec 2018 PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES Journal home page: http://www.pharmasm.com
More informationHPLC Winter Webinars Part 2: Sample Preparation for HPLC
HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do
More informationBenzoylecgonine in Urine by SAMHSA GC/MS
application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Benzoylecgonine in Urine by SAMHSA GC/MS Introduction The United States Department
More informationA Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil Hydrochloride by Validated HPLC Method
Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2018 A Pre-Clinical Pharmacokinetic-Pharmacodynamic Modelling and Biodistribution Studies of Donepezil
More informationHigh Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>
High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have
More informationIDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)
Document A. THIN LAYER CHROMATOGRAPHY (TLC) 1. SCOPE AND FIELD OF APPLICATION The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate
More informationSPE Method Development Tips and Tricks. Group/Presentation Title Agilent Restricted Month ##, 200X
SPE Method Development Tips and Tricks Sources of Error Generated and Time Spent During a Typical Chromatographic Analysis Contamination (4%) Columns (11%) Operator (19%) Sample Introduction (6%) Chromatography
More information[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples
[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples SIMPLE EASY EFFICIENT DEPENDABLE 2 waters.com/ostro 3 SIMPLE The Ostro Pass-Through Sample Preparation Product provides
More informationUltrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System
Ultrafast Analysis of and Metabolite in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Forensic Toxicology Authors Mohamed Youssef and Vaughn P. Miller Agilent
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationBasic Principles for Purification Using Supercritical Fluid Chromatography
Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,
More informationCHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs
CHAPTER - 3 ANALYTICAL PROFILE 3.1 Estimation of Drug in Pharmaceutical Formulation 3.1.1 Estimation of Drugs ANALYTICAL PROFILE 84 3.1 ESTIMATION OF DRUG IN PHARMACEUTICAL FORMULATION. Agrawal A et al
More informationAppendix II- Bioanalytical Method Development and Validation
A2. Bioanalytical method development 1. Optimization of chromatographic conditions Method development and optimization of chromatographic parameters is of utmost important for validating a method in biological
More informationultimate efficiency unleashed [ Cortecs 1.6 µm columns ]
ultimate efficiency unleashed [ Cortecs columns ] [ CORTECS UPLC COLUMNS ] A SUB--µm SOLID-CORE PARTICLE COLUMN THAT LIVES UP TO ITS POTENTIAL. C 8 + C 8 HILIC SOLID-CORE PARTICLE COLUMNS THAT DELIVER
More informationApplication Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India
Analysis of fumonisin, FB1 and FB2 mycotoxins in corn food and feed samples using the Agilent 1120 Compact LC System coupled to the Agilent 6140 Single Quadrupole LC/MS System Application Note Food Safety
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationTaking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline
Taking Full Advantage of UHPLC with Agilent 0A Triple Quadrupole MS Dr. Anabel Fandino R&D Application Scientist LC/MS Division Agilent Technologies Santa Clara, CA utline Ultra High Definition LC/MS using
More informationVALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION
VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic
More informationThiabendazole (TBZ) and benomyl are benzamidazolic
556 YOUNG ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 84, NO. 2, 2001 RESIDUES AND TRACE ELEMENTS Mixed-Mode Solid-Phase Extraction and Cleanup Procedures for the Liquid Chromatographic Determination of
More informationRapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies
Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies Jonathan Danaceau, Erin Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA, USA
More informationGemini-NX Performance paired with Axia Technology
Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationEPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS
EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of
More informationLC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode
LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode Application Note Authors Siji Joseph Agilent Technologies India Pvt. Ltd.
More informationFigure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)
Supported Liquid Extraction: Automate those Tiresome Bioanalytical Protocols L. Williams, H. Lodder, S. Merriman, A. Howells, S. Jordan, J. Labadie, M. Cleeve, C. Desbrow, R. Calverley and M. Burke 1 Argonaut
More informationQuantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection
Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 126 Infinity Binary LC system with UV detection Application Note Food Author Srividya Kailasam Agilent Technologies,
More informationState-of-the-art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%
More informationWilliam E. Barber, Ph.D. Applications Chemist October
William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC
More informationElectronic Supplementary Information. The selective response of templated polymer for the cationic drug
Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2017 Electronic Supplementary Information The selective response of templated polymer for the cationic
More informationQuantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.
Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction
More information[ a ppl ic at ion no t e ]
[ a ppl ic at ion no t e ] Fast A nalysis of A ldehydes and K etones by A C Q U I T Y U P L C Mark E. Benvenuti Waters Corporation, Milford, MA, USA INT RO DUC T ION Aldehydes and ketones are products
More informationDetermination of Pharmaceuticals in Environmental Samples
Determination of Pharmaceuticals in Environmental Samples BACKGROUND The full effects of pharmaceutical substances in the environment are largely unknown however the risk is significant enough that many
More informationNEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)
February 2009. NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications
More informationProntoSIL C18-EPS Reversed-Phase HPLC Columns
ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationMethods Development Process for Bioanalysis" Stuart Coleman March 22, 2007
Methods Development Process for Bioanalysis" Stuart Coleman March 22, 2007 What is Bioanalysis? In Bioanalysis,, we are measuring the quantity of molecules of interest (analytes) in a complex biological
More informationDEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM
IJPSR (2013), Vol. 4, Issue 2 (Research Article) Received on 28 September, 2012; received in revised form, 24 November, 2012; accepted, 23 January, 2013 DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR
More informationAnalysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF
application Note Liquid Chromatography/ Mass Spectrometry Author Sharanya Reddy PerkinElmer, Inc. Shelton, CT USA Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF
More informationBarry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000
Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationAbstract. Experimental Sample Preparation
Determination of Benzoylecgonine in Human Urine Using Automated, In-Line, ITSP Solid Phase Extraction and Liquid Chromatography Mass Spectrometric Detection Thurman L. Allsup 1, Kenneth C. Lewis 1 and
More informationisobaric Barbiturates in Serum using LDTD- MS/MS combined with differential mobility
Ultra-Fast Separation Ultra-Fast and Quantification Separation and of isobaric Barbiturates in Serum using LDTD- Quantification of isobaric MS/MS combined with differential mobility spectrometry Barbiturates
More informationChoosing Columns and Conditions for the Best Peak Shape
Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include
More informationPosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction
Introduction The study of protein expression allows a greater understanding of biological function and can now routinely be performed using mass spectrometry. However, analysis of the post-translational
More informationEPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS
Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the
More informationMinimizing Solvent Impact on Purification of Nitrogencontaining
Minimizing Solvent Impact on Purification of Nitrogencontaining Compounds J. Liu and P. C. Rahn Biotage Discovery Chemistry Group US 1725 Discovery Drive Charlottesville, VA 22911 USA 1 Abstract This paper
More informationImprove Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application
Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward
More informationSPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods
How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine
More informationExtraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis
Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco
More informationAnalysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction
Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction Application Note Consumer Products Authors Devon C. Zimmerman, Henry F. Rossi III, Jacqueline Rizzo, Daniel W. Keating,
More informationDetermination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes
Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes (50-6) Chin-Kai Meng Senior Applications Chemist Agilent Technologies March, 007 Page Introduction
More information