Does Hydrophilic Polydopamine Coating Enhance Membrane Rejection of

Size: px
Start display at page:

Download "Does Hydrophilic Polydopamine Coating Enhance Membrane Rejection of"

Transcription

1 1 Supporting Information Does Hydrophilic Polydopamine Coating Enhance Membrane Rejection of Hydrophobic Endocrine Disrupting Compounds? Hao Guo, Yu Deng, Zhijia Tao, Zhikan Yao, Jianqiang Wang, Chuner Lin, Tong Zhang, Baoku Zhu, Chuyang Y. Tang* Department of Civil Engineering, The University of Hong Kong, Pokfulam, Hong Kong, ERC Membrane and Water Treatment Technology (MOE), Department of Polymer Science and Engineering, Zhejiang University, Hangzhou , PR China These authors contributed equally *Corresponding Author: Chuyang Y. Tang, tangc@hku.hk, Number of pages (including the cover page): 11 Number of figures: 5 Number of tables: 2 1

2 Page 3 Page 4 Page 5 Page 6 Page 8 Page 9 Page 10 S1. Preparation of PDA coated membranes S2. Procedures of surface energy determination S3. Laboratory cross-flow filtration setup S4. UPLC-MS/MS operational conditions S5. Effect of PDA coating on the passage of BPA S6. Effect of filtration time on EDCs rejection S7. Extraction of EDCs

3 32 S1. Preparation of PDA coated membranes Pristine membrane coupons of suitable size (around 23.5 cm 12.0 cm) were thoroughly rinsed with deionized water to remove any impurities and were soaked in deionized water for 35 at least 24 h before coating. A membrane coupon was placed in a custom-designed container 36 (Figure S2) which only exposes the rejection layer side of the membrane. PDA coating was 37 performed by adding 300 ml 0.2 wt.% dopamine hydrochloride in 10 mm tris solution at ph The container was shaken at 60 rpm and coated for 0.5, 1, 2, and 4 h at room temperature 39 (~ 25 C) Figure S1. Illustration of custom-designed container for single-side PDA coating. 3

4 S2. Procedures of surface energy determination Three probing liquids, water (H 2 O, surface tension γ = mn/m), di-iodomethane (CH 2 I 2, γ = mn/m), and glycerol (C 3 H 8 O 3, γ = mn/m), were used to determine contact angles of various membranes using a contact angle goniometer (OCA20, Dataphysics, Germany) at 25 C. The measured contact angle values were corrected for the roughness effect by applying Wenzel equation: 1 cos = (1) where θ m is the measured contact angle, θ Y is the corrected contact angle, and r is membrane surface roughness ratio. The surface roughness ratio was determined by atomic force microscopy and calculated by the Nanoscope Software (Bruker, Camarillo, CA). Membrane surface energy was then calculated on the basis of corrected contact angle results of mentioned three liquid by the SCA software from DataPhysics (using Owens Wendt Kaelble approach)

5 57 S3. Laboratory cross-flow filtration setup Figure S2. Illustration of laboratory cross-flow filtration setup. Figure S2 illustrates the laboratory cross-flow filtration setup used in this study. The setup consists of three parallel cross-flow cells (CF042, Sterlitech, Kent, WA). Solution was placed in a stainless steel tank with an overhead mixer and a refrigerated cooling coils (JP Selecta, Barcelona, Spain). A high pressure pump (Wanner Engineering Inc., Minneapolis, MN) was used to recirculate and pressurize the water solution. A relief valve was set at the output tube of the pump to adjust the outlet pressure. Each cell was connected to a separate cross-flow tubing system equipped with a needle valve and a pressure relief valve to allow independent pressure setting for each cell. The solution temperature was maintained at 25 C during the 68 operation. 5

6 S4. UPLC-MS/MS operational conditions The four selected EDCs in this study were analyzed by UPLC-MS/MS. LC operational conditions were: Eluent A consisted of 95% water, 5% methanol, and 0.1 mm ammonium acetate; Eluent B contained 95% methanol, 5% water, and 0.1 mm ammonium acetate. The gradient eluting conditions were: initial hold at 20% A and 80% B, followed by a 1.5min gradient to 5% A and 95% B. Flow rate was 0.4 ml/min, sample injection volume was 10 ul, and sample room temperature was 10 C. MS detector operational mode was negative ion mode (ES-). Desolvation temperature was 400 C and source temperature was 120 C, observed capillary voltage was 2.5kV. Nitrogen was used as cone and desolvation gas, with the flow rate of 50 L/h and 600 L/h, separately. The pressure for collision gas (Argon) was set at mbar. The MS detector parameters are summarized in table S1. In order to prevent unexpected loss of EDCs, all the samples were directly taken from feed solution and permeate without further filtration. 5 Table S1. MS detector parameters. Compound Parent (m/z) Daughter (m/z) Dwell (s) Cone (V) Collision (V) Retention time (min) Ethylparaben Propylparaben Benzylparaben BPA In this study, serial calibration points ( µg/l) were used to calibrate the concentration of each compound. All the lowest calibration concentration of each analyte gave a 6

7 86 signal-to-noise (S/N) ratio above 10:1 (Figure S3), which is a critical value of instrumental 87 quantification limit (IQL). 6 The linearity of the tested dynamic range (i.e. the lowest 88 calibration concentration of each compound to the highest concentration used) also showed 89 good fit with linearity over 0.99 (Figure S3) Figure S3. Chromatograms of detected compounds (a) ethylparaben; (b) propylparaben; (c) benzylparaben; and (d) BPA at instrumental quantification limits within dynamic ranges. 7

8 95 S5. Effect of PDA coating on the passage of BPA Figure S4. Effect of PDA coating on the passage of BPA. Figure S4 gives the passage of BPA through membrane for original and PDA coated membranes. Significantly reduced passage was observed on PDA coated membrane compared with uncoated NF90. The hydrophilic PDA coating may weaken the hydrophobic interaction between BPA and membrane surface so that it can reduce the sorption, thus further decreases the passage

9 104 S6. Effect of filtration time on EDCs rejection 105 The rejection of EDCs was monitored at different filtration time (Figure S5). The rejection of 106 EDCs became stable within 12 h Figure S5. Effect of filtration time on EDCs rejection. 9

10 S7. Extraction of EDCs An EDC extraction experiment was conducted to evaluate the recovery ratio using 50% methanol as the extract solution. Briefly, a membrane coupon of 1 cm 2 cm (both uncoated NF90 or 4 h PDA coated NF90-C4) was immersed into 10 ml solution (200 ppb EDCs, 10 mm NaCl, and ph 6.6) and was shaken at 120 rpm for 12 h. A blank text without membrane coupon was also conducted to evaluate the sorption on container wall. After 12 h shaking, the membrane was taken out, gently rinsed with DI water, and put in 5 ml 50% methanol solution for EDC extraction (12 h, shaking at 120 rpm). Bulk solution samples were taken at beginning and end of the sorption tests and extraction tests. All the tests were triplicated. The results showed that the sorption of four EDCs on container wall was less than 7%. The recovery ratio for ethylparaben, propylparaben, benzylparaben, and BPA by NF90 and NF90-C4 were consistently high (Table S2). The results indicate that 50% methanol was effective to extract EDCs from the membranes Table S2. Recovery ratio (%) of four EDCs by using 50% methanol extraction Ethylparaben Propylparaben Benzylparaben BPA NF ± ± ± ± 3.2 NF90-C ± ± ± ±

11 REFERENCES 1. Wenzel, R. N., Resistance of solid surfaces to wetting by water. Ind. Eng. Chem. 1936, 28, Kaelble, D. H., Dispersion-polar surface tension properties of organic solids. J Adhes. 1970, 2, Owens, D. K.; Wendt, R. C., Estimation of the surface free energy of polymers. J. Appl. Polym. Sci. 1969, 13, Determination of the surface energy of a solid. urface-energy-of-a-solid/ 5. Ng, C. K.; Cao, B., What exactly are you filtering out? Environ. Sci. Technol. 2015, 49, Kasprzyk-Hordern, B.; Dinsdale, R. M.; Guwy, A. J., Multi-residue method for the determination of basic/neutral pharmaceuticals and illicit drugs in surface water by solid-phase extraction and ultra performance liquid chromatography positive electrospray ionisation tandem mass spectrometry. J. Chromatogr. A 2007, 1161,

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 1 Supporting Information 2 3 Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish. 4 5 John Moreman, Okhyun

More information

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Live Webinar : How to be more Successful with your ACQUITY QDa Detector? Q&A Transcript ---------------- Q - How do you generate multiple charges reproductively? A - If you use the same settings on the

More information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS Application Note Food Testing and Agriculture Author Chen-Hao (Andy) Zhai and Rong-jie Fu Agilent Technologies (Shanghai)

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539) Determination of ormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell P Column (EPA 539) Application Note Environmental Authors Rong-jie Fu and Chen-ao (Andy) Zhai Agilent Technologies

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chemistry Instrumental Analysis Lecture 37. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at

More information

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer APPLICATION NOTE 72385 Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer Authors Stephan Meding, Katherine Lovejoy, Martin Ruehl Thermo Fisher Scientific,

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2018 Electronic Supplementary Information Hyperbranched Poly(ionic liquid) Functionalized

More information

Mass Spectrometry in MCAL

Mass Spectrometry in MCAL Mass Spectrometry in MCAL Two systems: GC-MS, LC-MS GC seperates small, volatile, non-polar material MS is detection devise (Agilent 320-MS TQ Mass Spectrometer) Full scan monitoring SIM single ion monitoring

More information

Determination of urea in ultrapure water by IC-MS/MS

Determination of urea in ultrapure water by IC-MS/MS APPLICATION NOTE 72482 Determination of urea in ultrapure water by IC-MS/MS Authors Soon Fatt Lee, 1 Fiona Teh Hui Boon, 1 Chris Cheah Hun Teong, 1 and Jeff Rohrer 2 ¹Thermo Fisher Scientific, Singapore

More information

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE Translated English of Chinese Standard: GB31604.35-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA GB 31604.35-2016

More information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Heather A Brown, 1 Claudia Rossi, 2 and Lisa J Calton 1 1 Waters Corporation, Wilmslow, UK 2

More information

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS Application ote Food Testing & Agriculture Author Andy Zhai Agilent Technologies, Inc. Shanghai Co. Ltd.

More information

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,

More information

Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite

Degradation of Polyamide Nanofiltration and Reverse Osmosis Membranes by Hypochlorite Supporting Information of Degradation of Polyamide Nanofiltration and Reverse smosis Membranes by Hypochlorite Van Thanh Do 1, huyang Y. Tang 1,2,*, Martin Reinhard 3, James. Leckie 3 School of ivil &

More information

16 Malachite green 17 Leucomalachite green

16 Malachite green 17 Leucomalachite green 16 17 Leucomalachite green hydrochloride Leucomalachite green N N N + Cl - N N-[4-[[4-(dimethylamino)-phenyl] phenylmethylene]-2,5-cyclohexadien-1-ylidene ]-N-methylmethanaminium chloride C 23 H 25 ClN

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis Application Note AN785 Extraction of Aflatoxins and chratoxin From Dried Chili Using ISLUTE Myco prior to LC-MS/MS Analysis Page Extraction of Aflatoxins and chratoxin from Dried Chili Using ISLUTE Myco

More information

Supporting Information

Supporting Information 1 Supporting Information 2 3 Discovery and implications of C 2 and C 3 perfluoroalkyl sulfonates in aqueous film forming foams (AFFF) and groundwater 4 Krista A. Barzen-Hanson a and Jennifer A. Field b*

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry Application Note Doping Control Authors Prof. Maria Kristina Parr Freie Universität Berlin Institute

More information

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput MAY 2005 SEPARATION SCIENCE REDEFINED 31 Assay Transfer from HPLC to UPLC for Higher Analysis Throughput A typical HPLC assay was transferred and optimized for a Waters ACQUITY UPLC system to achieve both

More information

Electronic Supplementary Information (ESI)

Electronic Supplementary Information (ESI) Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2018 Electronic Supplementary Information (ESI) Multiphase surface growth of

More information

637. Thiamethoxam. HPLC method

637. Thiamethoxam. HPLC method 637. Thiamethoxam HPLC method CIPAC Collaborative Trial according to CIPAC Information Sheet N o 293 Dr. Sven Adolph Syngenta Crop Protection Münchwilen AG CH-4333 Münchwilen Switzerland May 212 page 1

More information

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 126 Infinity Binary LC system with UV detection Application Note Food Author Srividya Kailasam Agilent Technologies,

More information

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and 1 2 3 Supporting Information Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and Estrogens in Drinking Water of China: Comparison to the Parent Compounds 4 5 6 7 8 1 Laboratory

More information

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS [ application note ] A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS Patricia Revilla-Ruiz 1, Gordon Kearney 2,

More information

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System Application Note Authors Wenwen Wang, Zhe Cao Agilent Technologies, Inc. No.3, Wang Jing Bei Lu, Chao Yang District,

More information

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA). A Rapid and Sensitive Method for the Simultaneous Determination of and Cyanuric Acid in Infant Formulas, Adult utritional Products, and Protein Powders APPLICATIO BEEFITS Simultaneous high-throughput screening

More information

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation

More information

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1,

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1, DEVELOPMENT O PCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1, Takeshi Nakano 2 1 Nihon Waters K.K,.1-3-12 Kitashinagawa,

More information

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS Marian Twohig, Michael D. Jones, Dominic Moore, Peter Lee, and Robert Plumb Waters Corporation, Milford, MA, USA APPLICATION

More information

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe

More information

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Application Note Forensic and Toxicology - Criminalistics Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers Using the Agilent 126 Infinity II SFC and Detection by Coupled

More information

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS TIAFT 204 Toshikazu Minohata, Keiko Kudo 2, Kiyotaka Usui 3, Noriaki Shima 4, Munehiro Katagi 4, Hitoshi

More information

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Ken Meadows, Thermo Fisher Scientific, Runcorn, UK Application Note 20789 Key Words

More information

4.1 MATERIALS 4.2 EQUIPMENTS

4.1 MATERIALS 4.2 EQUIPMENTS 4.1 MATERIALS 1. Aceclofenac Moraceae Pharma Ltd., Uttarakhand, India 2. Diclofenac Arti Drugs Ltd., Mumbai, India 3. Paracetamol Moraceae Pharma Ltd., Uttarakhand, India 4. Para-aminophenol Hema Pharmaceuticals

More information

Routine MS Detection for USP Chromatographic Methods

Routine MS Detection for USP Chromatographic Methods Daniel S. Root, Thomas E. Wheat, and Patricia McConville Waters Corporation, Milford, MA, USA APPLICATION BENEFITS This approach enables mass spectral analysis of peaks directly from unmodified USP HPLC

More information

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION ACQUITY UPLC PDA LINEARITY There are two characteristics that

More information

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS CH.MOUNIKA*, M.KINNERA Research Article SIR.C.R.REDDY COLLEGE OF PHARMACEUTICAL SCIENCES, ELURU.

More information

Optimization of the sample preparation and extraction methodology

Optimization of the sample preparation and extraction methodology Supporting information Results and discussion Optimization of the sample preparation and extraction methodology Visual comparison of the slopes (curve in standard mixture vs MMC curve with identical concentration

More information

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories APPLICATION NOTE 65200 Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories Authors Neloni Wijeratne, Claudia Martins, Mary

More information

Determination of trace anions in concentrated hydrofluoric acid

Determination of trace anions in concentrated hydrofluoric acid APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion

More information

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode Application Note Authors Siji Joseph Agilent Technologies India Pvt. Ltd.

More information

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS Application Note Authors E. Michael Thurman and Imma Ferrer Center for Environmental

More information

Analysis of Polar Metabolites using Mass Spectrometry

Analysis of Polar Metabolites using Mass Spectrometry Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009. Translated English of Chinese Standard: GB5009.17-2014 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF GB THE PEOPLE S REPUBLIC OF CHINA National Food Safety Standard-Determination

More information

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method By Sharon Lupo and Frances Carroll Abstract The analysis of synthetic cannabinoids and their metabolites

More information

Determination of Pharmaceuticals in Environmental Samples

Determination of Pharmaceuticals in Environmental Samples Determination of Pharmaceuticals in Environmental Samples BACKGROUND The full effects of pharmaceutical substances in the environment are largely unknown however the risk is significant enough that many

More information

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution Marc Plante, Bruce Bailey, Christopher Crafts, Ian N. Acworth Thermo Fisher Scientific, Chelmsford,

More information

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies APPLICATION BENEFITS Regulatory guidelines and recommendations place a greater emphasis on the detection

More information

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range

More information

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Application Note Traditional Chinese Medicine Author Rongjie Fu Agilent Technologies

More information

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract. Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS Application Food Analysis Authors Sheher Mohsin Agilent Technologies, Inc. Schaumburg, Il USA Michael Zumwalt

More information

Hollow ceramic fiber supported ZIF-8 membrane with enhanced. gas separation performance prepared by hot dip-coating seeding

Hollow ceramic fiber supported ZIF-8 membrane with enhanced. gas separation performance prepared by hot dip-coating seeding Supporting information Hollow ceramic fiber supported ZIF-8 membrane with enhanced gas separation performance prepared by hot dip-coating seeding Kai Tao, Lujie Cao, Yichao Lin, Chunlong Kong * and liang

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine Comprehensive 2D-LC Analysis of Chinese Herbal Medicine The Agilent 1290 Infinity 2D-LC Solution Application Note Small Molecule Pharmaceuticals & Generics Author Sonja Krieger Agilent Technologies, Inc.

More information

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method Xiang He and Marta Kozak ThermoFisher Scientific, San Jose, CA,

More information

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009) February 2009. NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications

More information

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole

More information

HPLC Background Chem 250 F 2008 Page 1 of 24

HPLC Background Chem 250 F 2008 Page 1 of 24 HPLC Background Chem 250 F 2008 Page 1 of 24 Outline: General and descriptive aspects of chromatographic retention and separation: phenomenological k, efficiency, selectivity. Quantitative description

More information

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(1):231-238 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Mass spectrometric study of naproxen dimer anions

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India Analysis of fumonisin, FB1 and FB2 mycotoxins in corn food and feed samples using the Agilent 1120 Compact LC System coupled to the Agilent 6140 Single Quadrupole LC/MS System Application Note Food Safety

More information

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets Contact: Oliver el-atma Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Germany (OMCL

More information

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC. 7. Stability indicating analytical method development and validation of and in capsule dosage form by HPLC. 7.1 INSTRUMENTS AND MATERIALS USED 7.1.1 INSTRUMENTS 1. Shimadzu LC-2010 CHT with liquid chromatograph

More information

Sulfotepp impurities in Chlorpyrifos EC formulations

Sulfotepp impurities in Chlorpyrifos EC formulations Page 1 of 16 Method DAS-AM-01-058 Sulfotepp impurities in Chlorpyrifos EC formulations A. ABSTRACT Method DAS-AM-01-058 has been validated for the analysis of the relevant impurity sulfotepp in chlorpyrifos

More information

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes Application Note Food Safety Author Sunil Kulkarni Agilent Technologies

More information

DISCLAIMER: This method:

DISCLAIMER: This method: Inorganic arsenic determination in fresh mussels using water bath extraction and anion exchange chromatography-inductively coupled plasma mass spectrometry DISCLAIMER: This method: - has to be considered

More information

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS Peter Hancock 1, Cristiana C. Leandro 2,3, Brendan J. Keely 2 and Richard J. Fussell 3 1 Waters Corporation,

More information

Polymer Science, Series A, 2017, Vol. 59, No. 3 SUPPORTING INFORMATION. The Screening and Evaluating of Chitosan/β-cyclodextrin

Polymer Science, Series A, 2017, Vol. 59, No. 3 SUPPORTING INFORMATION. The Screening and Evaluating of Chitosan/β-cyclodextrin Polymer Science, Series A, 2017, Vol. 59, No. 3 SUPPORTING INFORMATION The Screening and Evaluating of Chitosan/β-cyclodextrin Nanoparticles for Effective Delivery Mitoxantrone Hydrochloride Yiwen Wang,

More information

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity Agilent 12 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity A case study with degraded omeprazole drug product Application Note Small Molecule

More information

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS Rapid and Simultaneous Analysis of Urinary Catecholamines and Metanephrines Using Mixed-Mode SPE and Hydrophilic Interaction Chromatography (HILIC) for Clinical Research Jonathan P. Danaceau, Erin E. Chambers,

More information

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Determination of iopromide in environmental waters by ion chromatography-icp-ms Determination of iopromide in environmental waters by ion chromatography-icp-ms Application note Environmental Authors Armando Durazo, Tarun Anumol, and Shane A. Snyder Department of Chemical & Environmental

More information

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Application Note: 56 Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS Yang Shi, Catherine Lafontaine, Matthew Berube, John Fink, François Espourteille Thermo

More information

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry Shijun Lua, Buu N. Trana, Jamie L. Nelsenb, Kenneth M. Aldousa. Journal of Chromatography

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION DOI: 10.1038/NCHEM.2633 Mechanically controlled radical polymerization initiated by ultrasound Hemakesh Mohapatra, Maya Kleiman, Aaron P. Esser-Kahn Contents 1. Materials and methods 2 2. Procedure for

More information

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID Asian Journal of Chemistry Vol. 21, No. 3 (2009), 1739-1746 Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID PRAVEEN KUMAR BALIYAN*, R.P.

More information

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance Michael D. Jones, Marian Twohig, Karen Haas, and Robert S. Plumb Waters Corporation,

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Tecan AC Extraction Plate

Tecan AC Extraction Plate Tecan AC Extraction Plate Simple sample preparation for the determination of vitamin D in serum by LC-MSMS Introduction A growing number of laboratories have moved from the use of immunoassay methods to

More information

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017. Final Report Title Characterisation of Job No 2016/11/12-34 AS No. 1234A Client Contact Sample Author report Signed Date 2017 Easy Reach Report 2017 v2.docx 1 of 33 Contents 1. Study Summary Page 3 2.

More information

PYRIPROXYFEN TECHNICAL

PYRIPROXYFEN TECHNICAL WHO/IS/TC/715/2001 TECHNICAL TECHNICAL 1. Specification 1.1 Description Interim specification WHO/IS/TC/715/2001 The material shall consist of pyriproxyfen together with related manufacturing impurities.

More information

Lecture 15: Introduction to mass spectrometry-i

Lecture 15: Introduction to mass spectrometry-i Lecture 15: Introduction to mass spectrometry-i Mass spectrometry (MS) is an analytical technique that measures the mass/charge ratio of charged particles in vacuum. Mass spectrometry can determine masse/charge

More information

A Protocol for High-Throughput Drug Mixture Quantitation: Fast LC MS or Flow Injection Analysis MS?

A Protocol for High-Throughput Drug Mixture Quantitation: Fast LC MS or Flow Injection Analysis MS? 60 LCGC VOLUME 19 NUMBER 1 JANUARY 2001 www.chromatographyonline.com A Protocol for High-Throughput Drug Mixture Quantitation: Fast LC MS or Flow Injection Analysis MS? The authors demonstrate the pros

More information

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Direct Determination of Small Organic Acids in Sea Water by IC-MS Direct Determination of Small Organic Acids in Sea Water by IC-MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Application Note Key Words MSQ Plus Single Quadrupole Mass

More information

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains:

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains: Details of the Analytical Procedures and Reactor Configurations. HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains: Analysis for initial PF surfactant and possible shorter-chain products

More information

TANDEM MASS SPECTROSCOPY

TANDEM MASS SPECTROSCOPY TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER

More information

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography Application Note Traditional Chinese Medicine Authors Xu Liang, Xi Zhang School of Pharmacy Second Military

More information

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide What is the MassHunter METLIN Metabolite PCD/PCDL? 2 Where to find more information 2 Kit Content 3 Installation 5 Before you start 5 Install MassHunter

More information

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry Supporting Information for: Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid Chromatography-Tandem Mass Spectrometry Ramin Vismeh a,b, Fachuang Lu c,d, Shishir

More information

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction Testing for GHB in hair by GC tandem quadrupole MS Marie Bresson, Vincent Cirimele, Pascal Kintz, Marion Villain; Laboratoire Chemtox, Illkirch, France Timothy Jenkins, Waters Corporation, Manchester,

More information

Validation Report 18

Validation Report 18 EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 18 Determination of pesticide residues in maize for livestock feed by GC-MS/MS and LC-MS/MS

More information

Investigation of Petasis and Ugi Reactions in Series in an Automated Microreactor System

Investigation of Petasis and Ugi Reactions in Series in an Automated Microreactor System Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2014 Supplementary Information Investigation of Petasis and Ugi Reactions in Series in an Automated

More information

Fumonisin. Fumonisin B 1 Fumonisin B 2. Fumonisin B 3. CAS No.:

Fumonisin. Fumonisin B 1 Fumonisin B 2. Fumonisin B 3. CAS No.: Fumonisin Fumonisin B 1 Fumonisin B 2 Fumonisin B 3 Fumonisin B 1 Fumonisin B 2 H H H H H H H H NH 2 H H NH 2 H C 34 H 59 N 15 MW: 721.8 CAS No.: 116355-83-0 H C 34 H 59 N 14 MW: 705.8 CAS No.: 116355-84-1

More information