- Garry Hood
- 5 years ago
- Views:
Transcription
1 QuantumMCA QuantumNaI QuantumGe QuantumGold
2 Berkeley Nucleonics Corporation (San Rafael, CA) and Princeton Gamma Tech (Princeton, NJ) have partnered to offer gamma spectroscopy with either germanium or sodium iodide detectors. A complete line of portable and benchtop systems will meet your spectroscopy needs. See or for the latest product information. QuantumGold QuantumGold, the premiere software package for qualitative and quantitative gamma analysis, is a true 32-bit application compatible with Windows 95/98/NT. Some of the exciting features of QuantumGold are: Simple, easy-to-understand user interface Multiple memory groups for processing spectra Peak deconvolution Quantitative analysis of spectra taken with germanium or sodium iodide detectors Ethernet network support for PGT multichannel analyzers One year of free software upgrades with a new purchase of QuantumGold QuantumMCA QuantumMCA is a multichannel analyzer emulation package which is supplied with all PGT multichannel analyzer instruments that require computer control. QuantumMCA allows you to perform the fundamentals of qualitative gamma spectrum analysis as well as to control all hardware functions. Its analytical tools are easy to use, with a visually intuitive user interface to make it easier to find commonly used functions. Qualitative Analysis The primary function of qualitative analysis is peak search and isotopic identification. The Tools Setup window gives you a powerful and flexible way to control these functions. All parameters associated with the peak search routine, ROI definitions, and many other basic analytical functions are defined in this window. The interactive peak display feature shows how the peak ROI is affected by the width parameters. As a parameter is changed, the graphical display is updated automatically. While some users prefer an automated approach to pulse height analysis, you may want to set and adjust ROI s manually before the peak information is calculated. Simply use the mouse and the Ctrl key to draw out each ROI. To adjust an ROI, just click the mouse cursor in the ROI to select it and then use the lower tool bar buttons to make the desired changes. The software can even deal with overlapped ROIs.
3 Quantum Software Intuitive user interface Easy to use analysis functions Toggle buttons through multiple selections Easy-to-use Tool Tips for Control displayed range menus all buttons with buttons or mouse Display up to 8 spectra, from as many as 8 different spectrometers or MCAs or from disk. Auxiliary display for full spectrum, convolution results, hardware controls. ROI info ROI adjust Quantitative Analysis Software That s Powerful and Easy to Use QuantumGold was designed to make quantitative analysis a pleasure. The information and data displays are intuitive and easy to understand. Consider the efficiency calibration process: simply open the detector calibration window, select the gamma lines that you wish to use for the calibration, and then press one button. The efficiency curve is automatically generated and displayed on the screen.
4 Calibration Certificate Database QuantumGold manages the certificate information for any number of calibration standards in a Microsoft Access database. Information on each standard, including those with multiple nuclides, can be entered into this database via a data entry window in the software. Decay corrections are then automatically performed when a particular standard is used in the calibration process. Peak Deconvolution QuantumGold performs a gaussian peak deconvolution to analyze spectra with overlapped peaks, including multiple overlapping ROIs within a multiplet. ROIs can also be manually inserted or removed and the deconvolution analysis repeated. Nuclide Library Quantum software includes three main libraries, each of which is tailored to a specific type of spectroscopy: Agamma library with over 100 isotopes, hundreds of gamma emissions, and numerous X-ray emissions associated with some radioactive decays An alpha library with 63 nuclides and 193 associated alpha emissions. Abeta library with 59 nuclides and 120 associated beta emissions. Libraries can be cloned and readily configured for specific applications. User Defined Spectrum Analysis For users who want to perform a more custom-oriented interactive data analysis, the "Convolutions" menu provides several functions that manipulate the acquired spectrum and place the result in a separate memory location for display and analysis. The available convolution filters include the following: Quadratic Smooth Top hat filter 1st and 2nd derivatives Peak finder Spectrum Calculator is a handy way to perform spectrum manipulation, such as adding spectra, subtracting, and other basic calculations. After the specified spectrum processing has been carried out, the software uses an available memory buffer to store/display the resulting spectrum.
5 Analytical Methods There are two analysis methods available in QuantumGold: library directed and ROI directed. The library-directed method first performs an automatic peak search according to the parameter settings in the Tools Setup window, with deconvolution if peak deconvolution has been selected. Peaks are then matched to the library lines of selected nuclides, and the nuclide identification is made accordingly. The next step involves the calculation of nuclide activities based on the efficiency correction data. Finally, the sample analysis report is generated, which displays activity information on the identified nuclides in order of level of confidence. The ROI-directed method allows a particular ROI to be manually assigned by the user to a specific gamma emission of a particular nuclide. This analytical method does not involve a peak search or library search for selected nuclides. An activity calculation is performed according to the net counts in each assigned ROI. This method can be particularly useful when an analysis needs to be performed on a specific list of nuclides that are known to be present. By the very nature of this method, nuclides that may be in the sample, but are of no interest, are automatically excluded in the analysis. One useful feature of this method is that MDAs are reported even when no net counts are measured for a particular ROI. QuantumMCA Reports QuantumMCA also generates several reports that give data in a useful concise format. These reports include: Channel data ROI data ROI detail Peak search Peak identify
6 Automated Control If you need to customize the operation of the software for a particular application, Q-Script is a flexible and easy-to-use software automation development tool. It has a menu-driven, design interface that allows you to construct an automated MCAbased sample counting and analysis routine. A comprehensive selection of commands is available. Q-Script commands can even allow the software to designate the values of logic signals on the rear panel auxiliary I/O connector of PGT multichannel analyzers. These logic signals can be used to control the actions of external hardware that accept control signals in this manner (e.g. a sample changer). Hardware Adjustment and System Calibration Automatic hardware adjustment of PGT gamma spectrometers is as simple as placing a Cs137 source near the detector and pressing one button. For sodium iodide based systems, the detector high voltage, coarse gain, and fine gain are automatically set. For safety purposes with germanium detector systems, the detector high voltage is set and adjusted manually. On both types of systems, automatic fine energy calibration is also available. Place a multi-line source (such as Eu152) near the detector, take a spectrum, and press the "Fine Energy Cal" button. A quadratic energy calibration is performed on the spectrum in memory. For a resolution calibration, you can use the same spectrum. Of course, if you prefer the manual method for setting the hardware and performing energy and resolution calibrations, this is also possible via the PC. Total hardware control via Quantum software makes for easy setup. The software also includes the facilities for a quick manual linear two-point energy calibration and a manual quadratic ROI centroid based method. You can also do a manual resolution calibration if desired. Auto-calibrate screen ready for Fine-Energy and Efficiency Calibrations Two-point linear calibration screen Energy Calibration by ROI Centroids
7 Quadratic Compression Conversion (QCC) Quadratic Compression Conversion represents the first major development in scintillation spectroscopy in nearly 25 years. NaI detectors have always been attractive for nuclear spectroscopy because they have reasonable energy resolution, are rugged, do not require cryogenic cooling, are physically small and have reasonably low cost. Unfortunately, NaI detectors suffer from a variety of problems such as: a non-linear response below about 200keV, low resolution compared to some other detectors, resolution that is a significant function of the gamma energy. QCC is a patented (#5,608,222) technology that minimizes these inherent drawbacks and significantly enhances the ability of the software to identify peaks and make the associated isotopic identifications. This technology is implemented in the MCA2100R and MCA2100 gamma spectrometers. For more information on QCC, see the product information sheet entitled, "Quadratic Compression Conversion - A New Way to do NaI Gamma Spectroscopy." Low energy peaks better defined 8000 channel linear spectrum of 60Co and 133Ba High energy peaks better defined 512 channel linear spectrum of 60Co and 133Ba All peaks equally well defined Networking and Communication with the MCA Hardware 512 channel QCC spectrum of 60Co and 133Ba The modern lab frequently has applications where more than one MCA needs to be connected to a single PC. Quantum software and PGT multichannel analyzer hardware address this requirement with two interface technologies: Ethernet (10/100 base-t) and RS232. No slots in the PC are required to use any PGT instrument. Likewise, the data from each instrument is managed by Quantum software in a logical and easily understood manner. Multiple spectrometers or MCAs can easily be controlled via one software package. The user can control whether to display the spectrum, not display it, copy it to new memory buffer, or delete it from memory. The number of memory buffers at this time is eight, and consequently, a maximum of eight PGT spectrometers and/or MCAs can be controlled by the Quantum software. PGT multichannel analyzers that are available with Ethernet include: MCA 2100R MCA 8000 Multichannel Analyzer System 8000 Gamma Spectrometer A convenient hardware search program is used to establish communication between all PGT MCAs that are connected to the local area network (LAN) via Ethernet (10/100 base-t) or the on-board RS-232 interface. By virtue of this hardware search technique, QuantumMCA automatically configures itself for the capabilities of each piece of hardware.
8 Supported hardware All PGT and BNC MCA's are compatible with QuantumMCA, the basic software package with no quantitative analysis capability. The list currently includes the following instruments. MCA (PGT) MCA2100R (PGT) MCA 4000 Multi-channel Analyzer (PGT) MCA 8000 Multi-channel Analyzer (PGT) Model 905 Smart Area Monitor - Berkeley Nucleonics Model 935 Surveillance and Measurement System - Berkeley Nucleonics By combining appropriate software (QuantumNaI, QuantumGe, or QuantumGold) and hardware (listed above), PGT has have created the following complete systems for gamma spectroscopy: System 8000 Gamma Spectrometer for Germanium Detectors System 4000 X-ray Spectrometer for Germanium and Si(Li) detectors MCA2100 Gamma Spectrometer for NaI Detectors MCA2100R Gamma Spectrometer for NaI Detectors. Distribuito in Italia da Active Radsys info@activeradsys.it tel: Fax:
GAMMA RAY SPECTROSCOPY
GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions
More informationNew happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist
New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist Genie-2000 Latest Features Cascade Summing Correction LACE (Line Activity Consistency Evaluator) Interactive Nuclide
More informationFRAM V5.2. Plutonium and Uranium Isotopic Analysis Software
V5.2 Plutonium and Uranium Isotopic Analysis Software Advanced Isotopic Ratio Analysis Software for HPGe Gamma-Ray Spectra Analyzes Pu, and a wide variety of heterogeneous samples containing Pu, Am, U,
More informationSCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION
SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system
More informationApplied Nuclear Science Educational, Training & Simulation Systems
WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology with the Latest in Radiation Detection Systems The Center For Innovative
More informationORTEC GammaVision -32 V6.09
ORTEC GammaVision -32 V6.09 Comprehensive Gamma Spectrum Analysis for HPGe detector spectra. Integrated control of spectroscopy hardware. Highly Automated and Highly Interactive modes of operation. Identification
More informationAUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING
ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research
More informationSoftware BioScout-Calibrator June 2013
SARAD GmbH BioScout -Calibrator 1 Manual Software BioScout-Calibrator June 2013 SARAD GmbH Tel.: ++49 (0)351 / 6580712 Wiesbadener Straße 10 FAX: ++49 (0)351 / 6580718 D-01159 Dresden email: support@sarad.de
More informationAlphaVision-5.3. Integrated, Ethernetconnected. spectrometers. 32-bit software for Windows 2000 and XP Professional ORTEC
AlphaVision-5.3 Integrated, Ethernetconnected alpha spectrometers 32-bit software for Windows 2000 and XP Professional Alpha Vision 5.3 What makes us the best???? We are the cutting edge!!!! Introduction
More informationAlpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year
Alpha spectrometry systems A users perspective George Ham Date Month Year 26 th May 2005 Centre for Radiation, Chemical and Environmental Hazards Radiation Protection Division formerly the National Radiological
More informationAlpha-energies of different sources with Multi Channel Analyzer (Item No.: P )
Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P2522015) Curricular Relevance Area of Expertise: ILIAS Education Level: Physik Topic: Hochschule Subtopic: Moderne Physik Experiment:
More informationCopyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy
Experiment VI Gamma Ray Spectroscopy 1. GAMMA RAY INTERACTIONS WITH MATTER In order for gammas to be detected, they must lose energy in the detector. Since gammas are electromagnetic radiation, we must
More informationTHE COMPTON EFFECT Last Revised: January 5, 2007
B2-1 THE COMPTON EFFECT Last Revised: January 5, 2007 QUESTION TO BE INVESTIGATED: How does the energy of a scattered photon change after an interaction with an electron? INTRODUCTION: When a photon is
More informationApplied Nuclear Science Educational, Training & Simulation Systems
WWW.NATS-USA.COM Applied Nuclear Science Educational, Training & Simulation Systems North American Technical Services Bridging Technology With The Latest in Radiation Detection Systems & Training Solutions
More informationAnalysis of γ spectrum
IFM The Department of Physics, Chemistry and Biology LAB 26 Analysis of γ spectrum NAME PERSONAL NUMBER DATE APPROVED I. OBJECTIVES - To understand features of gamma spectrum and recall basic knowledge
More informationfor XPS surface analysis
Thermo Scientific Avantage XPS Software Powerful instrument operation and data processing for XPS surface analysis Avantage Software Atomic Concentration (%) 100 The premier software for surface analysis
More information"Neutron Flux Distribution"
TECHNICAL UNIVERSITY DRESDEN Institute of Power Engineering Training Reactor Reactor Training Course Experiment "Neutron Flux Distribution" Instruction for Experiment Neutron Flux Distribution Content:
More informationMulti Channel Analyzer (MCA) Analyzing a Gamma spectrum
Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum Objective: Using the MCA to acquire spectrums for different gamma sources and to identify an unknown source from its spectrum, furthermore to investigate
More informationThe Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!
The Multi-Wiper HE High Energy Nuclear Medicine Well Counter The first multi-well counters designed specifically for Nuclear Medicine! * Comprehensive wipe testing with concise report in DPM * Available
More information2100TR Liquid Scintillation Counter
2100TR Liquid Scintillation Counter Description The Tri-Carb 2100TR liquid scintillation counter is computer-controlled, bench top liquid scintillation analyzer for detecting small amounts of alpha, beta
More informationJazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440
Jazan University College of Science Physics Department جاهعة جازان كلية العل وم قسن الفيزياء Lab Manual Nuclear Physics (2) 462 Phys 8 th Level Academic Year: 1439/1440 1 Contents No. Name of the Experiment
More informationIon-Chamber Survey Meter OD-02
Ion-Chamber Survey Meter OD-02 Dose and dose rate meter for measuring the ambient dose equivalent H*(10) and dose rate equivalent dh*(10)/dt as well as the directional dose equivalent H (0,07) and dose
More informationIdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications
fire IdentiFINDER Digital Hand Held Spectrometer & The world s smallest spectrometer and dose rate meter designed for portable applications. safety security identifinder - CH (yellow) CZT and neutron detector
More information4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.
EXPERIMENT 2.1 GAMMA ENERGY CALIBRATION 1- Turn the power supply on to 900 V. Turn the NIM crate on to power the amplifiers. Turn the Oscilloscope on to check the gamma pulses. The main amplifier should
More informationFoodScreen Radiological Food Screening System
Features Rapid screening of processed or raw food products for key 131I, 134 Cs and 137 Cs nuclides Clear, immediate indication if any nuclide-specific maximum permissible concentrations are exceeded Transportable
More informationFast, Effective XPS Point Analysis of Metal Components
Application Note: 52297 Fast, Effective XPS Point Analysis of Metal Components Chris Baily and Tim Nunney, Thermo Fisher Scientific, East Grinstead, West Sussex, UK Key Words K-Alpha Auto-Analysis Multi-Spectrum
More informationAlpha-Energies of different sources with Multi Channel Analyzer
Physical Structure of Matter Radioactivity Alpha-Energies of different sources with Multi Channel Analyzer What you can learn about Decay series Radioactive equilibrium Isotopic properties Decay energy
More informationPYCKO SCIENTIFIC LIMITED
PYCKO SCIENTIFIC LIMITED 31 London Road, Grantham, NG31 6EX Telephone 01476 401992 bill@pycko.co.uk www.pycko.co.uk Your Alternative To The Obvious RayMon10 TM Detect, measure, identify and analyse radionuclides
More informationGamma Ray Spectroscopy
Gamma Ray Spectroscopy Uzair Latif, Imran Younus Department of Physics Lahore University of Management Sciences November 4, 2014 1 Objectives 1. To acquaint the students with some of the basic techniques
More informationɣ-radiochromatography
nuclear instruments Kapitel_y_Graphy.indd 1 19.08.09 10:27 n u c l e a r i n s t r u m e n t s Index HPLC-detectors TLC-detectors GABI* analog output GABI* digital output to PC minigita*, 1 trace scanner
More informationGamma Spectroscopy. References: Objectives:
Gamma Spectroscopy References: G.F. Knoll, Radiation Detection and Measurement (John Wiley & Sons, New York, 2000) W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-to Approach,
More information1 of :32
Home Page Products Price List Links & PDFs DISCONTINUED: SEE GAMMA-RAD Gamma Ray & X-Ray Spectroscopy System Hand-Held, High Efficiency NaI(Tl) Detector The GAMMA-8000 is a powerful, portable instrument
More informationScintillation Detector
Scintillation Detector Introduction The detection of ionizing radiation by the scintillation light produced in certain materials is one of the oldest techniques on record. In Geiger and Marsden s famous
More informationSoftware for Whole-Body Counting and Lung Burden Analysis for NaI and HPGe Systems. In touch with today s Health Physics needs...
ORTEC Renaissance -32 V4 Software for Whole-Body Counting and Lung Burden Analysis for NaI and HPGe Systems Comprehensive... In touch with today s Health Physics needs... Simplify routine scans and tasks
More informationInformation on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance
BAM 6.8 8.5.213 Information on the test material EDS-TM2 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance 1. Introduction Energy dispersive spectrometers
More informationLS6500 Scintillation Counting Systems
LS6500 Scintillation Counting Systems Agenda LS6500 Concepts and Design H# Plus - The Basis of Advanced Technology Low Level Counting Alpha/Beta Discrimination LS6500 Concepts Give reproducible results
More informationIdentification of Naturally Occurring Radioactive Material in Sand
Identification of Naturally Occurring Radioactive Material in Sand Michael Pope 2012 NSF/REU Program Physics Department, University of Notre Dame Advisors: Dr. Ed Stech, Dr. Michael Wiescher Abstract Radionuclides
More informationDetection and measurement of gamma-radiation by gammaspectroscopy
Detection and measurement of gamma-radiation by gammaspectroscopy Gamma-radiation is electromagnetic radiation having speed equal to the light in vacuum. As reaching a matter it interact with the different
More informationGamma-Spectrum Generator
1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/
More informationMass of the electron m 0
Mass of the electron m 0 1 Objective To determine the rest mass of the electron, m e, via γ-ray interactions (mainly Compton scattering and photoeffect) in a NaI scintillation detector. Based on the enclosed
More informationGT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium
GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium Canada 1995 1 What is common on the current market Handheld
More informationhν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?
Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important
More informationGEOPHYSICAL GAMMA-RAY SPECTROMETER
CZECH REPUBLIC GEOPHYSICAL GAMMA-RAY SPECTROMETER GRM-260 Operating Manual Version 2.0 Brno, October 2001 Contents Technical specifications 3 1. Theory 4 2. Operating Instructions 7 2.1. GRM-260 Preparation
More informationPHY 192 Compton Effect Spring
PHY 192 Compton Effect Spring 2010 1 The Compton Effect Introduction In this experiment we will study two aspects of the interaction of photons with electrons. The first of these is the Compton effect
More informationNUCL 3000/5030 Laboratory 2 Fall 2013
Lab #2: Passive Gamma Spec Measurements in Decoding Natural Radioactivity in SLC Area Objectives a. Learn basics of gamma spectroscopy b. Learn the equipment in Counting stations #4, #5 and #8 c. Apply
More informationCreating Empirical Calibrations
030.0023.01.0 Spreadsheet Manual Save Date: December 1, 2010 Table of Contents 1. Overview... 3 2. Enable S1 Calibration Macro... 4 3. Getting Ready... 4 4. Measuring the New Sample... 5 5. Adding New
More informationMnova Software for Analyzing Reaction Monitoring NMR Spectra
Mnova Software for Analyzing Reaction Monitoring NMR Spectra Version 10 Chen Peng, PhD, VP of Business Development, US & China Mestrelab Research SL San Diego, CA, USA chen.peng@mestrelab.com 858.736.4563
More informationDUNPL Preliminary Energy Calibration for Proton Detection
DUNPL Preliminary Energy Calibration for Proton Detection DUNPL Professor Alexander Komives By: Josh Wyant and Andrew Bever Report Number: TR-PD01 April 28, 2005 Throughout the semester we have been working
More informationThe IAEA-CU world wide open proficiency test on the determination of radionuclides in soil, spinach and water
The IAEA-CU-2007-03 world wide open proficiency test on the determination of radionuclides in soil, spinach and water Laboratory s Final Report Laboratory Code: 146 (CuNo: 13949) Total Pages (with cover):
More informationX-ray fluorescence analysis - calibration of the X-ray energy detector
X-ray fluorescence analysis - TEP Related topics Bremsstrahlung, characteristic X-radiation, energy levels, fluorescence radiation, conduction processes in semiconductors, doping of semiconductors, pin-diodes,
More informationAUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING
ABSTRACT AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING J. Rynes, K.M.F. Biegalski, P. Donohoe, and S. Biegalski Veridian Pacific-Sierra Research
More informationPINS3-CF. Portable Chemical and Explosive Identification System
Portable Chemical and Explosive Identification System Portable Isotopic Neutron Spectroscopy System for the Identification of Chemical Warfare Agents, Explosives, and Toxic Industrial Chemicals without
More informationSLAC Radioanalysis Laboratory
SLAC Radioanalysis Laboratory Henry Brogonia Dosimetry and Radiological Protection Group (DREP) DOE Environmental Radiation Protection Program Review (July 23-24, 2007) Radioanalysis Laboratory Mission
More informationJasco V-670 absorption spectrometer
Laser Spectroscopy Labs Jasco V-670 absorption spectrometer Operation instructions 1. Turn ON the power switch on the right side of the spectrophotometer. It takes about 5 minutes for the light source
More information2008 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies SPECTRAL ANALYSIS OF RADIOXENON
SPECTRAL ANALYSIS OF RADIOXENON Matthew W. Cooper, Ted W. Bowyer, James C. Hayes, Tom R. Heimbigner, Charles W. Hubbard, Justin I. McIntyre, and Brian T. Schrom Pacific Northwest National Laboratory Sponsored
More informationNuclear Lifetimes. = (Eq. 1) (Eq. 2)
Nuclear Lifetimes Theory The measurement of the lifetimes of excited nuclear states constitutes an important experimental technique in nuclear physics. The lifetime of a nuclear state is related to its
More informationISOCS / LabSOCS. Calibration software for Gamma Spectroscopy
ISOCS / LabSOCS Calibration software for Gamma Spectroscopy Counts Setup Hardware Peak Shaping Parameters Rise Time Flat Top Pole-zero Number of Channels Signal Gain Setting up a detector for measurement
More informationShielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis
Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis The shielded γ-ray spectrometer of Dr. Westmeier GmbH employs a NaI(Tl) or other scintillation detector with good resolution inside
More informationThe Best Gamma-Ray Detector
/sec The Best Gamma-Ray Detector What is the best detector for gamma-ray spectroscopy? Amptek, Inc. provides signal processing electronics which can be used with a variety of detectors (some available
More informationSpectrometer User s Guide
Spectrometer User s Guide (Order Codes: V-SPEC, SPRT-VIS, SP-VIS, SP-UV-VIS, ESRT-VIS) The spectrometer is a portable light spectrophotometer, combining a spectrometer and a light source/cuvette holder.
More informationDISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion
DISTRIBUTION LIST To be filled out by Document Author or person requesting document deletion: Once approved, the new or revised document or the notice of deleted document(s) should be distributed to all
More informationLab 1 Uniform Motion - Graphing and Analyzing Motion
Lab 1 Uniform Motion - Graphing and Analyzing Motion Objectives: < To observe the distance-time relation for motion at constant velocity. < To make a straight line fit to the distance-time data. < To interpret
More informationM E E T I n s t r u m e n t s G.m.b.H.
T a m a r i s k e n g a s s e 1 0 2 / 1 3 / 5 A - 1 2 2 0 V i e n n a, A U S T R I A T e l : + 4 3 1 2 8 5 4 5 7 2, F a x : + 4 3 1 2 8 3 6 4 2 9 E - m a i l : office@mateval.com www.mateval.com Portable
More informationThe Evaluation of Program ISOTOPIC to Nondestructively Quantify Uranium and Plutonium Samples at the Joint Research Center in Ispra, Italy
Abstract The Evaluation of Program ISOTOPIC to Nondestructively Quantify Uranium and Plutonium Samples at the Joint Research Center in Ispra, Italy Richard Hagenauer, AMETEK/ORTEC, Oak Ridge, TN Pierre
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA
Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities- 13044 John A. Mason*, Richard Creed**, Marc R.
More informationInteractive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools
10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium
More informationBIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY
BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY UV/Vis Spectroscopy is a technique that is widely used to characterize, identify and quantify chemical compounds in all fields of analytical chemistry. The
More informationORTEC ISOTOPIC-32 V4.0
ORTEC ISOTOPIC-32 V4.0 ISOTOPIC V4 represents a SUBSTANTIAL move forward from previous versions of this program. Improvements to algorithms have been made, but in addition, great attention has been paid
More informationPhysics 476LW Advanced Physics Laboratory Atomic Spectroscopy
Physics 476LW Atomic Spectroscopy 1 Introduction The description of atomic spectra and the Rutherford-Geiger-Marsden experiment were the most significant precursors of the so-called Bohr planetary model
More informationPractical Solutions to Radioactive Waste Characterization
Practical Solutions to Radioactive Waste Characterization Ronald Keyser, Timothy Twomey EG&G ORTEC Richard Hagenauer Lockheed Martin Energy Systems, Oak Ridge, TN Abstract The movement or storage of containers
More informationRadiation Detection. 15 th Annual OSC Readiness Training Program.
Radiation Detection 15 th Annual OSC Readiness Training Program www.oscreadiness.org GM Detectors 15 th Annual OSC Readiness Training Program www.oscreadiness.org 1 A closer look 15 th Annual OSC Readiness
More informationGeneral Overview of Radiation Detection and Equipment
www.inl.gov INL/MIS-11-22727 General Overview of Radiation Detection and Equipment International Nuclear Safeguards Policy and Information Analysis Course Monterey Institute of International Studies June
More informationADVANCED SYNTHETICALLY ENHANCED DETECTOR RESOLUTION ALGORITHM: A SYSTEM FOR EXTRACTING PHOTOPEAKS FROM A SODIUM IODIDE SCINTILLATION DETECTOR SPECTRUM
ADVANCED SYNTHETICALLY ENHANCED DETECTOR RESOLUTION ALGORITHM: A SYSTEM FOR EXTRACTING PHOTOPEAKS FROM A SODIUM IODIDE SCINTILLATION DETECTOR SPECTRUM By ERIC LAVIGNE A THESIS PRESENTED TO THE GRADUATE
More informationQuality Assurance. Purity control. Polycrystalline Ingots
Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic
More informationRelativistic Electrons
Relativistic Electrons Physics 300 1 Introduction In this experiment you will make independent measurements of the momentum and kinetic energy of electrons emitted from a β source. You will use these data
More informationANGLE 4. Advanced Gamma Spectroscopy Efficiency Calibration Software
Advanced Gamma Spectroscopy Efficiency Calibration Software Compatible, Efficient, and Defendable Calibrations for Gamma Spectroscopy Applications. ANGLE is an advanced efficiency calculation application
More informationDistance from the face of the detector to the surface of the item being measured.
ORTEC Using the ORTEC ISO-CART and ISOTOPIC This guide is designed to assist the user of an ISO-CART /ISOTOPIC system in performing accurate nondestructive measurements of radioactive items in various
More informationBOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION
BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER Technical Description Version 2 BGRIMM AUTOMATION, South 4th Ring Road West, Beijing, China TEL: +86(10)59069762 Fax: +86(10)68360101 Contents BGRIMM AUTOMATION
More informationO P E R A T I N G M A N U A L
OPERATING MANUAL WeatherJack OPERATING MANUAL 1-800-645-1061 The baud rate is 2400 ( 8 bits, 1 stop bit, no parity. Flow control = none) To make sure the unit is on line, send an X. the machine will respond
More informationdn(t) dt where λ is the constant decay probability per unit time. The solution is N(t) = N 0 exp( λt)
(Aug. 2011 revision) Physics 307 Laboratory Experiment #3 Probability Distributions and the Decay of Excited Quantum States Motivation: The purpose of this experiment is to introduce the student to counting
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationElectric Fields and Equipotentials
OBJECTIVE Electric Fields and Equipotentials To study and describe the two-dimensional electric field. To map the location of the equipotential surfaces around charged electrodes. To study the relationship
More informationRMCC CANBERRA Latest developments
RMCC -2015 CANBERRA Latest developments Daniel Obrecht International Sales Manager CANBERRA Worldwide Presence 50 years in business Over 1,000 employees 7 industrial sites Canada Sweden Germany Belgium
More informationRADIOACTIVITY IN OUR ENVIRONMENT GAMMA-RAY SPECTRA II
RADIOACTIVITY IN OUR ENVIRONMENT GAMMA-RAY SPECTRA II Objectives to recognize that each kind of radioactive nucleus emits an unique set of energies of gamma rays to become familiar with the use of an high
More informationExperience the most powerful benchtop NMR spectrometer
Experience the most powerful benchtop NMR spectrometer Outstanding Features Highest field strength (80 MHz) Largest chemical shift spread Highest sensitivity Superb Resolution (0.5 Hz/20 Hz) Multi-nuclear
More informationThermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization
Thermo Scientific K-Alpha + XPS Spectrometer Fast, powerful and accessible chemical analysis for surface and thin film characterization X-ray Photoelectron Spectroscopy Quantitative, chemical identification
More informationM E R C E R W I N WA L K T H R O U G H
H E A L T H W E A L T H C A R E E R WA L K T H R O U G H C L I E N T S O L U T I O N S T E A M T A B L E O F C O N T E N T 1. Login to the Tool 2 2. Published reports... 7 3. Select Results Criteria...
More informationAdvanced Gamma Spectroscopy
Nuclear Division Scientech Advanced Gamma Spectroscopy Spin and Parity of ground state 18 Sb124 20.2 m IT 26.0, e γ 10.9D,e 5+ 1.6m IT 10.9,e β 1.2,... γ 602.7,645.8 498.4,... 3 60.20 d β.61, 2.301, γ
More informationDependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution
Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Chikkappa Udagani Abstract: This paper presents the precise method to estimate the dependence of linear and mass
More informationHigh Purity Germanium Detector Calibration at ISOLDE
High Purity Germanium Detector Calibration at ISOLDE Guðmundur Kári Stefánsson Summer Student of Maria Borge September 5, 2013 Abstract: This Summer Student Project involved the test and calibration of
More informationarxiv:nucl-ex/ v2 21 Jul 2005
Gamma-spectrometric uranium age-dating using intrinsic efficiency calibration arxiv:nucl-ex/0506029v2 21 Jul 2005 Cong Tam Nguyen and József Zsigrai Institute of Isotopes of the Hungarian Academy of Sciences
More informationProject Memorandum. N N o. = e (ρx)(µ/ρ) (1)
Project Memorandum To : Jebediah Q. Dingus, Gamma Products Inc. From : Patrick R. LeClair, Material Characterization Associates, Inc. Re : 662 kev Gamma ray shielding Date : January 5, 2010 PH255 S10 LeClair
More informationNew Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology
New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue
More informationAgilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent
More informationNMR Predictor. Introduction
NMR Predictor This manual gives a walk-through on how to use the NMR Predictor: Introduction NMR Predictor QuickHelp NMR Predictor Overview Chemical features GUI features Usage Menu system File menu Edit
More informationElemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer
Elemental analysis by X-ray f luorescence Sequential benchtop WDXRF spectrometer Elemental analysis is one of the most important fundamental measurements made for industrial quality control and research
More informationX-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination
Uppsala University Department of Physics and Astronomy Laboratory exercise X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination
More informationInvestigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC
Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC A. Specification Whole body counting method is used to detect the gamma rays emitted by radio nuclides,
More informationSkin Damage Visualizer TiVi60 User Manual
Skin Damage Visualizer TiVi60 User Manual PIONEERS IN TISSUE VIABILITY IMAGING User Manual 3.2 Version 3.2 October 2013 Dear Valued Customer! TiVi60 Skin Damage Visualizer Welcome to the WheelsBridge Skin
More information