Applications. Overview of applications of elevated temperature and temperature programmed liquid chromatography

Size: px
Start display at page:

Download "Applications. Overview of applications of elevated temperature and temperature programmed liquid chromatography"

Transcription

1 Applications Overview of applications of elevated temperature and temperature programmed liquid chromatography The applications are arranged by field of interest Fundamental page 2 Pharmaceutical page 4 Biochemical page 11 Environmental page 12 Chemical page 15 Food page 22 Polymers page 24 1

2 FUNDAMENTAL 1 Increasing efficiency and resolution by coupling columns at elevated temperature A test mixture is used to demonstrate the effect of coupling columns on efficiency and resolution. (F. Lestremau, A. Cooper, R. Szucs, F. David, P. Sandra, J. Chromatogr. A 1109 (2006) ) Increasing efficiency/resolution Column Zorbax StableBond C18, 250x4.6 mm, 5 µm Mobile phase Water/acetonitrile Isocratic 60/40 v/v UV 210 nm C 25 cm (1 column) 6 Rs 6/7 = 19 7 Sample: 1 Uracil 2 Caffeine 3 Pyridine 4 Phenol 5 Aniline 6 Benzene 7 Toluene C 25 cm (1 column) 6 Selectivity Rs 6/7 = 15 N7 = 20, C 100 cm (4 columns) Rs 6/7 = 30 N7 = 78, C 200 cm (8 columns) Efficiency/Resolution Rs 6/7 = 45 N7 = 162,

3 Maintaining analysis time C 25 cm (1 column) 1 ml/min Rs = C 100 cm (4 columns) 2 ml/min Rs =

4 PHARMACEUTICAL 1 Fast analysis of benzalkonium chloride N + R Column Selerity Blaze200 C18, 100x2.1 mm, 3 µm Mobile phase A= 0.5% ammoniumformate/0.1% formic acid B= acetonitrile Gradient 20 to 90% B in 4.5 min 1.1 ml/min Temperature 140 C C12 UV 262 nm CH 3 CH 3 - Cl R ~ C 8H 17 C 22H 45 C14 C16 C18 C The method enables fast analysis of the various benzalkonium chloride homologues. Elevated temperature is combined with high flow rate. A volatile mobile phase is used enabling detection methods like mass spectroscopy, corona aerosol discharge, and evaporative light scattering. 2 Determination of benzalkonium chloride in pharmaceutical formulation Temperature was used for the analysis of various benzalkonium chloride homologues in a pharmaceutical formulation. Selectivity is significantly affected by analysis temperature. Additionally, the use of high temperature speeds up the analysis. 4

5 Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase Buffer/acetonitrile Isocratic 50/50 v/v 2 ml/min UV 214 nm BAC C12 Polymer Polaratherm: 60 C BAC C14 Polaratherm: 80 C Polymer Polaratherm: 100 C Polymer (Min) 3 Analysis of pharmaceutical compounds Increasing resolution I A mixture of a pharmaceutical compound and impurities is analyzed in a conventional and high resolution set-up. Significantly higher resolution is obtained with the same analysis time. Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase A= formic acid in water B= formic acid in acetonitrile Gradient UV 239 nm 90 C 300 (2x150) mm column 0.45 ml/min Sample: Mixture of main compound and impurities 90 C 600 (4x150) mm column 0.9 ml/min

6 4 Analysis of pharmaceutical compounds Increasing resolution II Temperature and selectivity Column Zorbax SB300-C18, 250x4.6 mm, 5 µm Mobile phase Formic acid in water/acetonitrile Isocratic 50/50 v/v 1 ml/min UV 254 nm Sample: Mixture of active and impurities 1 3 Impurities elute after compound Room temperature 25 cm (1 column) Impurities elute in front of compound C 25 cm (1 column) Normal and high resolution 60 C 25 cm (1 column) C 125 cm (5 columns) A complete separation of all compound is obtained with the high resolution set-up (5 columns coupled in series). 6

7 5 Influence of temperature on the analysis of sulfonamides Selectivity and speed Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase A = 0.1% acetic acid in water B = 0.1% acetic acid in acetonitrile Gradient 20 to 50% B in 2 min UV 270 nm 40 C 0.6 ml/min Sample: 1 Sulfamethizole 2 Sulfamethazine 3 Sulfachlorpyridazine 4 Sulfamethoxine 60 C 0.6 ml/min 2 Selectivity 80 C 0.6 ml/min 2 Speed 60 C 1.2 ml/min Temperature programming - GREEN CONDITIONS 7

8 Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase A = 0.1% acetic acid in water B = 0.1% acetic acid in ethanol Gradient 17 to 50% B in 3 min 0.6 ml/min UV 270 nm Isotherm 80 C T-program C 20 C/min

9 6 Comparison of solvent and temperature programming for the analysis of sulfonamides Column Hypercarb, 100x3 mm, 5 µm Mobile phase A = 0.1% acetic acid in water B = 0.1% acetic acid in ethanol 0.5 ml/min UV 273 nm MS ESI+, scan m/z Isocratic 50%B Isotherm 50 C Sample: 1 Sulfamethizole 2 Sulfamethazine 3 Sulfachlorpyridazine 4 Sulfamethoxine 4 Gradient 0 to 5 min 50 to 100%B Isotherm 50 C Isocratic 50%B T-program 0 to 2 min 40 C hold 2 to 9 min 40 to 180 C (20 C/min) Peak area (MS) 3.E+07 2.E+07 MS sensitivity Temperature program Mobile phase program 1.E+07 0.E Peak number A sulfonamide standard mixture is analyzed with LC-MS using a solvent gradient or a temperature gradient. A temperature gradient provides better peak shape and detectability. The ionization efficiency is not affected by changes in mobile phase composition when a temperature program is used instead of a solvent gradient. (G. Vanhoenacker, P. Sandra, J. Sep. Sci. 29 (2006) ) 9

10 7 Analysis of sulfonamides on a temperatureresponsive stationary phase Column Mobile phase Home-made PNIPAA (poly(n-isopropylacrylamide))- modified aminopropyl, 150x4.6 mm, 5 µm 100% water 1 ml/min UV 254 nm % water 25 C Sample: 1 Sulfamethizole 2 Sulfamerazine 3 Sulfamethoxazole 4 Sulfadimethoxine 5 Sulfaquinoxalin % water 55 C The surface properties and functions of a temperature-responsive stationary phase are controlled by temperature. Retention and selectivity can thus be altered by changing the analysis temperature. (G. Vanhoenacker, P. Sandra, J. Sep. Sci. 29 (2006) ) 10

11 BIOCHEMICAL High efficiency separation of tryptic digest High efficiency separations of tryptic digest samples were obtained on conventional LC equipment by coupling eight 25 cm columns in series at 60 C. A peak capacity of ca. 900 was obtained using this set-up. (P. Sandra, G. Vanhoenacker, J. Sep. Sci. 30 (2007) ) Column Zorbax SB300-C18, 2000(=8x250)x2.1 mm, 5 µm Mobile phase A=0.1% TFA in water/acetonitrile 98/2 v/v B=0.1% TFA in water/acetonitrile 30/70 v/v Gradient 0 to 70%B in 520 min 0.2 ml/min Temperature 60 C UV 214 nm BSA Digest Serum Digest Peak Capacity ~ Serum Digest Detail min

12 ENVIRONMENTAL 1 Fast analysis of phenylurea pesticides Significant temperature dependent selectivity changes can be observed for the mixture of a phenylurea pesticides. At elevated temperature, the flow rate can be increased to shorten the analysis time. Column Zorbax StableBond C18, 50x2.1 mm, 1.8 µm Mobile phase Water/acetonitrile Isocratic 70/30 v/v UV 245 nm C ml/min 7 (tr 11.4 min) (tr 4.9 min) 60 C 0.35 ml/min 80 C 0.35 ml/min Sample: 1 Fenuron 2 Metoxuron 3 Chlortoluron 4 Diuron 5 Isoproturon 6 Linuron 7 Chloroxuron (tr 2.1 min) 80 C 0.85 ml/min

13 2 Influence of temperature on selectivity for the analysis of phenylurea and triazine pesticides (G. Vanhoenacker, P. Sandra, J. Sep. Sci. 29 (2006) ) Column Zorbax StableBond C18, 150x4.6 mm, 1.8 µm Mobile phase A=water B=acetonitrile Gradient 20 to 55%B in 30 min 1 ml/min UV 230 nm 50 C T1 T2 P1 P2 T3 T4 P3 T5 P6 P5 P4 P7 P8 T6 T7 T8 +P9 P10 T9 T10 90 C T1 T2 T4 P1 P2 T3 P5 T5 P8 P3 P4 P6 P7 T6 +P9 T7 T8 T9 T10 P10 T-program T1 T2 P1 P2 T3 T4 P3 P4 T5 P5 P6 P7 P8 T6 T7 P9 T8 P10 T9 T Triazine pesticides Peak Phenylurea pesticides Peak Desisopropylatrazine T1 Fenuron P1 Desethylatrazine T2 Metoxuron P2 Simazine T3 Methabenzthiazuron P3 Cyanazine T4 Chlortoluron P4 Atrazine T5 Monolinuron P5 Sebuthylazine T6 Diuron P6 Propazine T7 Isoproturon P7 Terbuthylazine T8 Metobromuron P8 Prometryn T9 Linuron P9 Terbutryn T10 Chloroxuron P10 13

14 3 High efficiency separation of PCB mixture A high efficiency separation of a polychlorinated biphenyl (PCB) mixture is obtained on conventional LC equipment by coupling eight 25 cm columns in series at 80 C. A peak capacity of over 300 was obtained using this set-up. (F. Lestremau, A. Cooper, R. Szucs, F. David, P. Sandra, J. Chromatogr. A 1109 (2006) ) Column Zorbax StableBond C18, 250x4.6 mm, 5 µm Mobile phase A=water, B=acetonitrile Gradient 50 to 100%B Temperature 80 C UV 214 nm Sample: Mixture of Arochlor 1242, 1254, and 1260 (1/1/1 ratio) 25 cm (1 column) 1 ml/min Peak Capacity ~ cm (4 columns) 2 ml/min Peak Capacity ~ cm (8 columns) 1 ml/min Peak Capacity ~

15 CHEMICAL 1 Analysis of naphthylamine isomers Mobile phase selection Column Zorbax SB-CN, 150x3 mm, 3.5 µm Mobile phase A= water B= methanol, acetonitrile, or ethanol Gradient 0.6 ml/min Temperature 40 C UV 220 nm B=acetonitrile 20 to 60% in 20 min 6 7 B=methanol 30 to 80% in 20 min B=ethanol 25 to 75% in 20 min Green chromatography Sample: 1 Aniline 2 α-naphthylamine 3 β-naphthylamine 4 α-naphthol 5 β-naphthol 6 N-phenylα-naphthylamine 7 N-phenylβ-naphthylamine 15

16 Column Zorbax SB-CN, 150x3 mm, 3.5 µm Mobile phase Temperature 80 C UV 220 nm A= water B= ethanol Gradient 0.6 ml/min: 10 to 60% ethanol in 20 min 1.2 ml/min: 10 to 60% ethanol in 10 min 80 C water/ethanol 0.6 ml/min 1.2 ml/min

17 2 Polar compounds I Resolution and speed Column Blaze C8, 150x4.6 mm, 3 µm Mobile phase Phosphate buffer in water/acetonitrile Gradient UV 290 nm 70 C 1 ml/min Sample: Mixture of wide variety of polar compounds 3 4 Resolution 100 C 1 ml/min Speed 100 C 1.8 ml/min

18 3 Polar compounds II Temperature programming The use of a temperature program leads to a reduced analysis time and an improved signal-to-noise for the late eluting compounds. Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase Acetic acid in water/isopropanol 94/6 v/v Isocratic 0.42 ml/min UV 254 nm Sample: Mixture of polar compounds Isotherm 40 C T-program 0-4 min 40 C, hold 4-6 min 40 to 80 C (20 C/min) 6 min 80 C, hold

19 4 Polysulfides An isothermic solvent gradient method for the analysis of a polysulfide sample is compared to an isocratic temperature-programmed method. Selectivity is significantly influenced by temperature and mobile phase composition (e.g. relative position in chromatogram of sulphur peak). Column Zorbax StableBond C18, 150x3 mm, 3.5 µm 0.42 ml/min DAD, 254 nm Sample Polysulfide mixture containing free sulphur Internal standard Free sulphur Polysulfides 40 C Ternary solvent gradient water/acetonitrile/ isopropanol Free sulphur T-program min 40 C min C (10 C/min) Isocratic 100% acetonitrile Free sulphur T-program 0-4 min 50 C 4-8 min C (10 C/min) Isocratic Ethanol/water

20 5 Increased resolution for the analysis of a complex reaction mixture The resolution for a separation of various compounds in a complex reaction mixture is significantly improved by coupling columns in series. Column Zorbax Eclipse XDB C18, 750(=3x250)x4.6 mm, 5 µm Mobile phase A=ammonium acetate in water B=acetonitril Gradient 50 to 100% B 1 ml/min Temperature 50 C UV 234 nm 250 mm (1 column) 50 to 100% B in 40 min mm (3 columns) 50 to 100% B in 120 min Sample: Reaction mixture

21 6 High efficiency analysis of phenones The theoretical chromatographic efficiency(n) of an LC setup can be calculated as follows: N = L/2dp (L=column length, dp = particle size) Eight 25 cm long, 5 µm dp columns coupled in series should ideally yield ca. 200,000 plates. Column Zorbax SB300-C18, 250x2.1 mm, 5 µm Mobile phase A=water, B=acetonitrile 0.2 ml/min Temperature 60 C Sample: phenone mixture UV 245 nm Ac Acetanilide C2 Acetophenone C3 Propiophenone C4 Buterophenone C5 Valerophenone Efficiency (N): C6 Hexanophenone C7 Heptanophenone Theory Bz Benzophenone 200,000 Isocratic 70% acetonitrile Ac C2 C4 C3 Bz C5 C6 C7 Chromatogram 201, ,000 C4 C5 C6 C7 Bz Ac C2 C3 Gradient 50 to 90% acetonitrile in 90 min

22 FOOD 1 High resolution analysis of citrus extracts Conventional columns were coupled in series to increase the efficiency and resolution for the analysis of a mixture of lemon and orange oil. The calculated peak capacity was approximately 260 for a 60 min gradient. (G. Vanhoenacker, P. Sandra, J. Sep. Sci. 29 (2006) ) Column Zorbax StableBond C18, 1000(=4x250)x4.6 mm, 5 µm Mobile phase A= water, B= acetonitrile Gradient 40% B 0 to 10 min 40 to 100% B 10 to 70 min 1.5 ml/min Temperature 80 C UV 315 nm Lemon/orange oil Detail

23 2 Sub-ambient temperature programming for the analysis of triglycerides Sunflower oil is analyzed on a reversed-phase column under isocratic conditions using a sub-ambient temperature program to increase resolution. Column Hypersil ODS, 200(=2x100)x 4.6, 3 µm Mobile phase Acetonitrile/Isopropanol/Hexane Isocratic 55/40/5 v/v Flow-rate: 1 ml/min : UV 214 nm Diglycerides Sample: Sunflower oil Triglyceride composition: Isotherm 25 C L = linoleic acid O = oleic acid P = palmitic acid S = stearic acid T-program 0 to 25 C 1.3 C/min T-program -20 to 5 C 1.3 C/min PLL OLO SLL PLO LLL OLL PLL OLO SLL PLO LLL OLL PLL OLO SLL PLO LLL OLL

24 POLYMERS Influence of temperature on the analysis of octylphenol ethoxylates Selectivity for the analysis of octylphenol ethoxylates was significantly affected by temperature in reversed phase LC. The elution order of the oligomers was reversed comparing separations at ambient and elevated temperature. (G. Vanhoenacker, P. Sandra, J. Chromatogr. A 1082 (2005) ) Column Zorbax StableBond C18, 150x3 mm, 3.5 µm Mobile phase Water/acetonitrile Isocratic 50/50 v/v 0.6 ml/min UV 225 nm Polaratherm: 20 C High MW Low MW Sample: Standard solution of Triton X-100 (O ) n OH Polaratherm: 50 C n ~1-20 Polaratherm: 90 C Low MW High MW

Method Development in Comprehensive 2D-LC Finding the Most Orthogonal Separation Systems for RPLC RPLC Using Column and Solvent Screening

Method Development in Comprehensive 2D-LC Finding the Most Orthogonal Separation Systems for RPLC RPLC Using Column and Solvent Screening Method Development in Comprehensive 2D-LC Finding the Most Orthogonal Separation Systems for RPLC RPLC Using Column and Solvent Screening Technical Overview Author Sonja Krieger Agilent Technologies, Inc.

More information

Better HPLC Methods Using Temperature Programming

Better HPLC Methods Using Temperature Programming Better HPLC Methods Using Temperature Programming Stephanie J. Marin Brian A. Jones, W. Dale Felix Selerity Technologies, Inc. Salt Lake City, UT www.selerity.com 1 Abstract Temperature programmed liquid

More information

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Analysis of Pesticides by Supercritical Fluid Chromatography/ Mass Spectrometry Optimizing the Agilent 126 Infi nity Analytical SFC System in Combination with the Agilent 646 Triple Quadrupole LC/MS Application

More information

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography Technical Overview 2D-LC Conventional 1D-LC Abstract This Technical Overview presents

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

CHEM340 Tutorial 4: Chromatography

CHEM340 Tutorial 4: Chromatography CHEM340 Tutorial 4: Chromatography 1. The data in the table below was obtained from a chromatogram obtained with a 10 cm liquid chromatography column. Under the conditions used, the compound uracil is

More information

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump Performance characteristics of the Agilent 129 Infinity Quaternary Pump Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview presents Proof

More information

CHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data

CHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data Introduction The enrichment of hydrophilic analytes from polar matrices is a challenge because they often cannot be retained by C 18 / C 8 -modified silica or hydrophobic polymer adsorbents. To overcome

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

A C18 Silica Column With Exceptional Temperature and ph Stability

A C18 Silica Column With Exceptional Temperature and ph Stability A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies,

More information

High Resolution Fast LC

High Resolution Fast LC High Resolution Fast LC Easier Than You Think Rita Steed LC Columns Application Engineer May 9, 2013 What is High Resolution Fast LC? Maintain Resolution with Faster Run Time Increased Resolution with

More information

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note Developing a fast, generic method for rapid resolution LC with quadrupole MS detection Combining the Agilent 6140 quadrupole MS and multimode source with the Agilent 1200 Series Rapid Resolution LC system

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates Using the Agilent 9 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates Technical Overview Author Florian Rieck Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical

More information

Lab scale isolation of compounds by Flash Chromatography

Lab scale isolation of compounds by Flash Chromatography Lab scale isolation of compounds by Flash Chromatography Lab scale isolation of compounds by Flash Chromatography - Rapid and reliable transfer from TLC to Flash Chromatography Properties of Silica Gel

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

Journal of Chromatography A

Journal of Chromatography A Journal of Chromatography A, 1216 (2009) 642 658 Contents lists available at ScienceDirect Journal of Chromatography A journal homepage: www.elsevier.com/locate/chroma Review Sense and nonsense of high-temperature

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

2. a) R N and L N so R L or L R 2.

2. a) R N and L N so R L or L R 2. 1. Use the formulae on the Some Key Equations and Definitions for Chromatography sheet. a) 0.74 (remember that w b = 1.70 x w ½ ) b) 5 c) 0.893 (α always refers to two adjacent peaks) d) 1.0x10 3 e) 0.1

More information

Open Column Chromatography, GC, TLC, and HPLC

Open Column Chromatography, GC, TLC, and HPLC Open Column Chromatography, GC, TLC, and HPLC Murphy, B. (2017). Introduction to Chromatography: Lecture 1. Lecture presented at PHAR 423 Lecture in UIC College of Pharmacy, Chicago. USES OF CHROMATOGRAPHY

More information

HPLC Separation Fundamentals. Ed Kim Application Engineer Agilent Technologies, Inc January 14, 2009

HPLC Separation Fundamentals. Ed Kim Application Engineer Agilent Technologies, Inc January 14, 2009 HPLC Separation Fundamentals Ed Kim Application Engineer Agilent Technologies, Inc January 14, 2009 Separation fundamentals Presentation Outline Major HPLC modes Key Equations Resolution van Deemter Common

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Supercritical Fluid Chromatography: Past, Present and Future

Supercritical Fluid Chromatography: Past, Present and Future Supercritical Fluid Chromatography: Past, Present and Future e-sear November 16, 211 Pat Sandra ... I love CO 2 as mobile phase Green Better than NP-LC Cheaper than LC Faster than LC Unique selectivity

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis High-Resolution Sampling D-LC for Pharmaceutical Impurity Analysis Detection of Impurities Hidden Under the API Peak at Relevant Levels Application Note Small Molecule Pharmaceuticals and Generics Authors

More information

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion

More information

Evaporative Light Scattering Detector (ELSD)

Evaporative Light Scattering Detector (ELSD) BÜCHI Labortechnik AG Evaporative Light Scattering Detector (ELSD) Martin Verstegen ELSD 3300 page 1 Overview of Common HPLC Detectors 1. UV/Vis 2. RI 3. Fluorescence 4. Mass Spectrometry 5. ELSD page

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Separation of Structurally Similar Steroids on HALO C18 and PFP

Separation of Structurally Similar Steroids on HALO C18 and PFP Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,

More information

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Luna 2.5 µm C18(2)-HST Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Table of Contents Part 1 Theory 1.1 Abstract...3 1.2 Introduction...3 Part 2 Set Up 2.1

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

Next Generation of Phenyl Columns. Chromatography Products.

Next Generation of Phenyl Columns. Chromatography Products. Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both

More information

LC-MS compatible Separation of the Fungicide Spiroxamine

LC-MS compatible Separation of the Fungicide Spiroxamine Spiroxamine is a systemic fungicide, which was brought to the market by Bayer CropScience. The substance is a mixture of diastereomers A and B again consisting of 4 enantiomers A1, A2, B1 and B2 (fig.

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Fast peaks in chromatograms of Sudan dyes

Fast peaks in chromatograms of Sudan dyes Journal of Chromatography A, 1160 (2007) 227 234 Fast peaks in chromatograms of Sudan dyes Kadi Mölder, Allan Künnapas, Koit Herodes, Ivo Leito Institute of Chemical Physics, University of Tartu, Jakobi

More information

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were . Introduction.,3 Dichloro Benzoyl Cyanide (,3 DCBC) and survey of analytical methods,3-dcbc substance, is the although advanced intermediate,3-dcbc is a of lamotrigine well-known bulk drug chemical manufactured

More information

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25 High Performance Liquid Chromatography (HPLC) Harris Chapter 25 12/1/2005 Chem 253 - Chapter 25 1 HPLC Separation of nonvolatile or thermally unstable compounds. If the analyte/sample can be found to be

More information

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases Agilent 129 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent

More information

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters Application Angelika Gratzfeld-Huesgen Abstract This application has been verified using an Agilent

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Monica Dolci, Luisa Pereira, and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Abstract This poster summarizes the

More information

Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think!

Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think! Tips and Tricks of Faster LC Analysis Without Capital Investment It may be easier than you think! Agilent Technologies, Inc. Fall 28 Page 1 There Are Many Reasons to Reduce Analysis Time Run More Samples/Day

More information

LUMEFANTRINUM LUMEFANTRINE

LUMEFANTRINUM LUMEFANTRINE July 2008 LUMEFANTRINE: Final text for addition to The International Pharmacopoeia (July 2008) This monograph was adopted at the Forty-second WHO Expert Committee on Specifications for Pharmaceutical Preparations

More information

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software Application Sergey Galushko Ralf Honsberg Abstract The development of an HPLC method is

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

A Look at Agilent HPLC Columns Choices

A Look at Agilent HPLC Columns Choices A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle

More information

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

ACE ACE. HPLC and UHPLC Columns. Product Catalogue ACE HPLC and UHPLC Columns Product Catalogue ACE Ultra-Inert, Base Deactivated HPLC & UHPLC Columns ACE Ultra-Inert, Base Deactivated HPLC and ACE Excel UHPLC columns give you the choices you need to

More information

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography Analytical Potential of Stable Phases for Reversed-Phase Liquid Chromatography by Jacek Nawrocki, Jon Thompson,

More information

Validated HPLC Methods

Validated HPLC Methods Validated HPLC Methods To Tweak or Not to Tweak Slide 4 Adjustments of operating conditions to meet system suitability requirements may be necessary. USP 23 p1776 Slide 5 001816S1.PPT What is the line

More information

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection 150 LCGC NORTH AMERICA VOLUME 23 NUMBER 2 FEBRUARY 2005 www.chromatographyonline.com HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection A new detection method based upon aerosol charging

More information

HPLC Analysis of Non-volatile Analytes Using

HPLC Analysis of Non-volatile Analytes Using HPLC Analysis of Non-volatile Analytes Using Charged Aerosol Detection Paul H. Gamache, Ryan S. McCarthy, Scott M. Freeto, Darwin J. Asa, Matthew J. Woodcock, Katherine Laws and Roderic O. Cole ESA Inc.,

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

M M e M M H M M H. Ion Sources

M M e M M H M M H. Ion Sources Ion Sources Overview of Various Ion Sources After introducing samples into a mass spectrometer, the next important step is the conversion of neutral molecules or compounds to gas phase ions. The ions could

More information

CHAPTER 6 GAS CHROMATOGRAPHY

CHAPTER 6 GAS CHROMATOGRAPHY CHAPTER 6 GAS CHROMATOGRAPHY Expected Outcomes Explain the principles of gas chromatography Able to state the function of each components of GC instrumentation Able to state the applications of GC 6.1

More information

The new Agilent 1290 Infinity Quaternary LC

The new Agilent 1290 Infinity Quaternary LC The new Agilent 1290 Infinity Quaternary LC How binary pump-like performance can enhance your lab efficiency Sebastian Krahe Produktspezialist HPLC Agilent Technologies Page 1 The 1290 Infinity Quaternary

More information

Agilent 1200 Series Rapid Resolution LC and Rapid Resolution LC/MS Optimization Guide

Agilent 1200 Series Rapid Resolution LC and Rapid Resolution LC/MS Optimization Guide Agilent 1200 Series Rapid Resolution LC and Rapid Resolution LC/MS Optimization Guide Authors: Angelika Gratzfeld-Huesgen, Michael Frank, Christian Gotenfels Table of Contents Introduction 5 1. Theory

More information

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed Chromatographic Methods of Analysis Section 2: Planar Chromatography Prof. Tarek A. Fayed Planar chromatography includes two types: 1- Thin Layer Chromatography (TLC). 2- Paper Chromatography (PC). Thin

More information

High Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger

High Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger High Temperature Ultra Fast Liquid Chromatography Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger Conclusions 1. To do fast LC, use a WEAK eluent and a HOT column.. Use a highly retentive

More information

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software

Automated LC Method Development: Fundamentals and Columns, Hardware, and Software An Executive Summary Automated LC Method Development: Fundamentals and Columns, Hardware, and Software Dr. William Long Application Scientist in the LC Columns marketing group Agilent Technologies Andreas

More information

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Agilent ZORBAX Column Selection Guide for HPLC Here it is your single

More information

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018 ACD/AutoChrom Assisted Method Development for Challenging Separations Vera Leshchinskaya February 7, 2018 Introduction Resolution of isomeric species is one of the most challenging areas of separation

More information

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for? Chromatography- Separation of mixtures CHEM 212 What is solvent extraction and what is it commonly used for? How does solvent extraction work? Write the partitioning coefficient for the following reaction:

More information

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS Application Note Traditional Chinese Medicine Author Rongjie Fu Agilent Technologies

More information

Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008

Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008 Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008 Page 1 What are the Parameters Affecting Resolution? Isocratic Separations: physical and chemical separation

More information

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC Slide 4 001284P1.PPT Seminar Outline 1. Gel-filtration separations by SEC 2. Developing methods for protein and peptide separations

More information

Analgesics / Cough 1 & Cold Medicine Ingredients

Analgesics / Cough 1 & Cold Medicine Ingredients Analgesics / Cough & Cold Medicine Ingredients mau H. paracetamol H CH H H. -aobenzoic acid H H H C CH. -hydroxybenzoic acid 7 CH H CH. caffeine 8 9 H. -acetamidophenol 0 H H. -hydroxybenzoic acid H C8-AR

More information

Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox

Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox Rosario LoBrutto Pharmaceutical and Analytical Development Novartis Pharmaceuticals Overall Strategy

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

HPLC Praktikum Skript

HPLC Praktikum Skript HPLC Praktikum Skript Assistants: Gianluca Bartolomeo HCI D330, 3 46 68, bartolomeo@org.chem.ethz.ch Sahar Ghiasikhou HCI E330, 2 29 29, ghiasikhou@org.chem.ethz.ch 1. Introduction In chromatographic techniques,

More information

Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development

Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development Investigation of retention mechanisms in HILIC chromatography: Important considerations for robust method development Anders Fridström Sigma- Aldrich GMBH Abstract Investigation of Retention Mechanisms

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application Pharmaceuticals Author Cliff Woodward and Ronald Majors Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

SUPERCRITICAL FLUID CHROMATOGRAPHY AS SUCCESSFUL SEPARATION TOOL IN CHEMICAL AND PHARMACEUTICAL INDUSTRY

SUPERCRITICAL FLUID CHROMATOGRAPHY AS SUCCESSFUL SEPARATION TOOL IN CHEMICAL AND PHARMACEUTICAL INDUSTRY 9th Meeting on Supercritical Fluids Trieste (Italy), 13-16 June 2004 SUPERCRIAL FLUID CHROMATOGRAPHY AS SUCCESSFUL SEPARATION TOOL IN CHEMICAL AND PHARMACEUAL INDUSTRY M. Johannsen *, S. Peper, G. Brunner

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs Value of Eclipse Plus C18 and ph Selectivity to Analyze Ae-Containing Drugs Application Pharmaceuticals Authors John W. Henderson Jr., William J. Long, and Cliff Woodward Agilent Technologies 285 Centerville

More information

On the Advantages and Costs of Two-dimensional HPLC (2D-LC)

On the Advantages and Costs of Two-dimensional HPLC (2D-LC) On the Advantages and Costs of Two-dimensional HPLC (2D-LC) Georges Guiochon, Krisztìan Horvàth, Jacob Fairchild CoSMoS, Boston, 08/3-5/2009 1 What is Chromatography About? Separating Components of Mixtures

More information

with diode array detection

with diode array detection Application Note Small Molecule Pharmaceuticals Analysis of Tween 8 by highperformance liquid chromatography with diode array detection Authors Jianxin Yu, Scott Citrowske, Nikki Carlson, and Jacob Strange

More information

This method describes the identification of the following prohibited colorants in cosmetic products:

This method describes the identification of the following prohibited colorants in cosmetic products: A. IDENTIFICATION BY TLC 1. SCOPE AND FIELD OF APPLICATION This method describes the identification of the following prohibited colorants in cosmetic products: Names C I number Pigment Orange 5 12075 Metanil

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008) July 2008 ARTEMETER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008) This monograph was adopted at the Forty-second W Expert Committee on Specifications

More information

Characterization of Carbon SPE for the Extraction of Polar Analytes

Characterization of Carbon SPE for the Extraction of Polar Analytes Characterization of Carbon SPE for the Extraction of Polar Analytes Cory Szafranski, Lydia Nolan, and William R. Betz Supelco, Supelco Park, Bellefonte, PA 16823 USA 1997 Sigma-Aldrich Co. T497277 BNG

More information

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography Tips and Techniques to Optimize ELSD and MS based Purification Utilizing ELSD and MS as Secondary Detectors for Prep

More information

Application Note. Food. Abstract. Author

Application Note. Food. Abstract. Author Selective Analysis of on-utritive Food Additives Using Agilent ZRBAX Eclipse Plus C, Eclipse Plus Phenyl-Hexyl, Eclipse XDB-Phenyl, and StableBond SB-Phenyl Columns Application ote Food Author Anne E.

More information