ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Size: px
Start display at page:

Download "ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A"

Transcription

1 Nuclear Instruments and Methods in Physics Research A 598 (2009) Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: Dual-Readout calorimetry with crystal calorimeters N. Akchurin a, M. Alwarawrah a, A. Cardini b, G. Ciapetti c, R. Ferrari d, S. Franchino d, M. Fraternali d, G. Gaudio d, J. Hauptman e, F. Lacava c, L. La Rotonda f, M. Livan d, E. Meoni f, D. Pinci c, A. Policicchio f, S. Popescu a, G. Susinno f,y.roh a, W. Vandelli g, T. Venturelli f, C. Voena c, I. Volobouev a, R. Wigmans a, a Texas Tech University, Lubbock (TX), USA b Dipartimento di Fisica, Università di Cagliari and INFN Sezione di Cagliari, Italy c Dipartimento di Fisica, Università di Roma La Sapienza and INFN Sezione di Roma, Italy d Dipartimento di Fisica Nucleare e Teorica, Università di Pavia and INFN Sezione di Pavia, Italy e Iowa State University, Ames (IA), USA f Dipartimento di Fisica, Università della Calabria and INFN Cosenza, Italy g CERN, Genève, Switzerland article info Article history: Received 3 September 2008 Received in revised form 1 October 2008 Accepted 9 October 2008 Available online 1 November 2008 Keywords: Calorimetry Cherenkov light Crystals Optical fibers abstract The hadronic performance of a Dual-Readout calorimeter consisting of a crystal em section and a hadronic section read out with two types of optical fibers is studied with 200 GeV p þ. The em fraction of hadronic showers developing in this calorimeter system is determined event by event from the relative amounts of Cherenkov light and scintillation light produced in the shower development. Data are presented for two types of crystals (PbWO 4 and BGO), each of which offers unique opportunities in this respect. The information obtained with this technique may lead to an important improvement in the hadronic calorimeter performance. & 2007 Elsevier B.V. All rights reserved. 1. Introduction In many modern particle physics experiments, the calorimeter systems are primarily designed to meet performance requirements for the detection of electron and g showers. The choices made to achieve this may turn out to have detrimental consequences for the quality of hadronic shower detection [1]. In recent years, a promising new technique has been developed, which is not subject to the limitations (e.g., a small sampling fraction) traditionally required for excellent hadron calorimetry: the Dual REAdout Method (DREAM). DREAM calorimeters are based on a simultaneous measurement of different types of signals which provide complementary information about details of the shower development. The first calorimeter of this type was based on a copper absorber structure, equipped with two types of active media. In this detector, scintillating fibers measured the total energy deposited by the shower particles, while Cherenkov light, generated by the charged, relativistic shower particles, was produced in undoped optical fibers. Since the shower particles generating Cherenkov light are almost Corresponding author. Tel.: ; fax: address: wigmans@ttu.edu (R. Wigmans). exclusively found in the em shower component (dominated by p 0 s produced in hadronic showers), a comparison of the two signals made it possible to measure the energy fraction carried by this component, f em, event by event. As a result, the effects of fluctuations in this component, which are responsible for all traditional problems in non-compensating calorimeters, could be eliminated, and the hadronic shower energy was correctly reconstructed based on the electron calibration and the two measured hadronic signals. This led to an important improvement in the hadronic calorimeter performance [2 4]. In a recent paper [5], we have demonstrated that the same technique, and the advantages it offers for hadron calorimetry, can in principle also be applied to homogeneous calorimeters, whose signals are a mixture of scintillation and Cherenkov light. The improvement of the calorimeter performance is in that case determined by the precision with which the relative contributions of these two types of light to the total signal can be determined. This precision was limited by the fact that we used a very small ðo5%þ forward/backward asymmetry to determine these contributions. Yet, the applicability of the principle was clearly established for the lead tungstate ðpbwo 4 Þ crystals used in these experiments. However, the fact that the crystals had to be oriented at an angle of 631 (i.e., the Cherenkov angle, y C ) with respect to the direction of the incoming particles in order to /$ - see front matter & 2007 Elsevier B.V. All rights reserved. doi: /j.nima

2 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) observe the mentioned asymmetry means that this method cannot be used in a realistic 4p experiment. In the present paper, we describe follow-up measurements that were performed with the goal of improving the above results in PbWO 4. In these measurements, we rely on differences in the time structure of the signals, rather than on the directionality of the light. This time structure was measured with a highresolution (2.5 GHz) sampling oscilloscope. We also did measurements with another type of crystal (BGO), which offers additional advantages compared to PbWO 4. Even though Cherenkov light represents a much smaller fraction of the total BGO signal, it is easier to recognize because of large differences in the optical spectra and time structure. In Section 2, we describe the detectors and the experimental setup in which they were tested. In Section 3, we discuss the experimental data that were taken and the methods used to analyze these data. The experimental results obtained with a single BGO crystal and with the PbWO 4 19-crystal matrix are presented in Sections 4 and 5, respectively. A brief summary and conclusions are given in Section Detectors and experimental setup 2.1. Detectors and readout The calorimeter system used in these experiments consisted of two sections. The electromagnetic section (ECAL) consisted of scintillating crystals, and the hadronic section was the original DREAM fiber calorimeter [2 4]. During one series of experiments, an ECAL consisting of 19 lead tungstate ðpbwo 4 Þ crystals was used. 1 Each crystal was 18 cm long, with a cross-section of 2:2 2:2cm 2. These crystals were arranged in a matrix, as shown in Fig. 1. The crystals were not optically isolated from each other, and the light produced by showering particles was read out by only two photomultiplier tubes (PMTs), one located at each end of the crystal matrix, as indicated by the circle in Fig. 1. For the purpose of these tests, this ensemble of crystals was considered one unit. The PMTs were specially selected for this application, for which we needed a light detector that was fast, had a large surface area and a low gain. This unusual combination of properties was found in XP4362B, 2 a 6-stage PMT (nominal gain 10 4 ) with a 3-in. active surface area and a nominal rise time of 2.0 ns. In another series of experiments, we used a single crystal of Bi 4 Ge 3 O 12 (BGO) as an electromagnetic calorimeter, placed upstream of the DREAM fiber calorimeter. This 24 cm long crystal was tapered, with a front face 3 of 2:4 2:4cm 2 and a rear face of 3:2 3:2cm 2. This crystal was read out with PMTs 4 from both ends. In between each crystal face and the PMT, an optical filter was mounted. For the smaller (front) face, a yellow filter (Y) was used, while the light exiting through the larger (rear) face had to pass through an ultraviolet (UV) filter. 5 The reasons for this arrangement are explained in Section 4. The basic element of the hadronic DREAM calorimeter section was an extruded copper rod, 2 m long and 4 4mm 2 in crosssection. This rod was hollow, and the central cylinder had a 1 On loan from the ALICE Collaboration, who use these crystals for their PHOS calorimeter. 2 Manufactured by Photonis, France. 3 The terms front and rear refer to the orientation of the crystal in the experimental setup (Fig. 3). 4 Hamamatsu R1355, square (28 mm), 10-stage, with a mm 2 bialkali photocathode. 5 Schott UG11 (UV) and GG495 (yellow). Filter thickness 3 mm. Fig. 1. The matrix of 19 PbWO 4 crystals that served as the em section of the calorimeter system. The circle indicates the size and the positioning of the PMTs used to detect the light generated in this matrix. diameter of 2.5 mm. Seven optical fibers were inserted in this hole. Three of these were plastic scintillating fibers, the other four fibers were undoped, intended for detecting Cherenkov light. The instrumented volume had a length of 2.0 m ð10l int ; 100X 0 Þ, an effective radius of 16.2 cm and a mass of 1030 kg. The fibers were grouped to form 19 hexagonal towers. The effective radius of each tower was 37.1 mm ð1:82r M Þ. A central tower was surrounded by two hexagonal rings. The towers were longitudinally unsegmented. The fibers sticking out at the rear end of this structure were separated into 38 bunches: 19 bunches of scintillating fibers and 19 bunches of Cherenkov fibers. In this way, the readout structure was established. Each bunch was coupled through a 2 mm air gap to a PMT. 6 Extensive tests of this hadronic calorimeter module have shown that the combined information on the scintillation ðsþ and Cherenkov ðcþ light generated by hadronic showers made it possible to measure the em shower fraction event by event. As a result, this detector provided the same advantages as compensating calorimeters, despite e=h values of 1.3 and 4.7 for the S and C readout structures, respectively: a Gaussian response function, hadronic signal linearity, an energy resolution 7 that scales with E 1=2 and, most importantly, correct reconstruction of the hadronic shower energy based on a calibration with electrons. Detailed information about this detector, and about the mentioned performance in stand-alone mode, is given in Refs. [2,3] Experimental setup All measurements described in this paper were performed in the H4 beam line of the Super Proton Synchrotron at CERN. The calorimeters were mounted on a platform that could move vertically and sideways with respect to the beam. Two small scintillation counters (TC) provided the signals that were used to trigger the data acquisition system. These trigger counters were 2.5 mm thick, and the area of overlap was 66cm 2. A coincidence 6 Hamamatsu R580, 10-stage, f 38 mm, bialkali photocathode, borosilicate window. 7 p s=e ¼ 64%= ffiffiffi E þ 0:6% for GeV jets, dominated by leakage fluctuations.

3 712 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 2. Schematic (not to scale) of the experimental setup in which the PbWO 4 crystal matrix was tested in conjunction with the DREAM fiber calorimeter. Not shown is a cm 2 scintillation counter placed 8 m downstream of the DREAM calorimeter behind a 80 cm thick concrete block, which served as a muon counter. between the logic signals from these counters provided the trigger. The trajectories of individual beam particles could be reconstructed with the information provided by two small drift chambers (DC1, DC2) which were installed upstream of the trigger counters. This system made it possible to determine the location of the impact point of the beam particles at the calorimeter with a precision of typically 0:2mm. These and other aspects of the experimental setup used for the tests involving the PbWO 4 matrix are illustrated in Fig. 2. The crystal matrix was oriented such that the crystal axes were parallel to the beam direction (see also Fig. 1). In this way, this em calorimeter represented an absorber with an effective depth of 20X 0. The two PMTs used to detect the light produced in the crystals will be called PMT A and PMT B, respectively. The experimental setup used for the tests involving the BGO crystal is schematically shown in Fig. 3. The crystal axis coincided with the beam line, so that the 24 cm long crystal represented an em calorimeter with a depth of 21X 0. The crystal was oriented as shown, with the yellow filter (Y) located upstream and the UV filter downstream. Because of the much larger light yield (compared to the PbWO 4 ECAL), combined with the higher PMT gain, it was necessary to limit the rate of the beam particles to about 1 khz in these tests. The much higher rates that were easily available in this beam line led to non-linearities resulting from excessive anode currents. Because of the small cross-section of the crystals (even em showers experienced more than 20% lateral energy leakage in the BGO crystal), it was not deemed useful to use an upstream interaction target for these measurements. Fig. 3 shows the type of event studied here: a hadron starting a shower inside the BGO crystal, whose energy is shared with the DREAM detector. Since the interaction length of the crystal was slightly more than 1l int, the majority of the beam hadrons were indeed of this type Data acquisition Measurement of the time structure of the calorimeter signals formed a very important part of the tests described here. In order to limit distortion of this structure as much as possible, we used special 15 mm thick cables to transport the crystal signals to the counting room. Such cables were also used for the signals from the trigger counters, and these were routed such as to minimize delays in the DAQ system. 8 The HCAL signals were transported through RG-58 cables with (for timing purposes) appropriate lengths to the counting room. The crystal signals were sent into a unity-gain Linear Fan-out unit, output signals of which were used to measure the time structure and the total charge. The data acquisition system used VME electronics. A single VME crate hosted all the needed readout and control boards. The 8 We measured the signal speed to be 0:78c in these cables. charge measurements of the calorimetric signals from the crystals and the DREAM towers were performed with 2 CAEN V792AC QADC 32-channel modules, 9 each channel offering 12-bit digitization at a sensitivity of 100 fc/count and a conversion time below 10 ms. The signals from the muon counter were integrated and digitized with a sensitivity of 100 fc/count, on a 12-bit LeCroy 1182 module. 10 The timing information of the tracking chambers was recorded with 1 ns resolution in a 16-bit 16-channel LeCroy 1176 TDC. 11 The time structure of the calorimeter signals was recorded by means of a Tektronix TDS 7254B digital oscilloscope, 12 which provided a sampling capability of 5 GSample/s, at an analog bandwidth of 2.5 GHz, over four input channels. During most of the data taking period only two channels were sampled, i.e., from the two PMTs reading out both sides of the crystal (matrix). The oscilloscope gain (scale) was tuned in order to optimize the exploitation of the 8-bit dynamic range, maintaining both a good sensitivity and a small fraction of overflow events. The PbWO 4 signals were measured over a time interval of 112 ns, during which time 282 data points were collected. The BGO signals, which had a considerably longer decay time, were followed over a time interval that was twice as long, and measurements were performed every 0.8 ns. The quality of the information obtained in this way is illustrated in Fig. 4, which shows the average time structure of the signals from a pion crossing a single PbWO 4 crystal perpendicularly. As will be shown in Section 5, this excellent time resolution made it possible to distinguish the prompt Cherenkov peak from the fast decay component ðo10 nsþ of the PbWO 4 scintillation light. The trigger logic was implemented through NIM modules and the signals sent to a VME I/O register, which was also catching the spill and the global busy information. Moreover, the system was able to inject pedestal triggers during the data taking, enabling the parallel recording of pedestal data. Pedestal events were flagged with a special signal on VME I/O register. The VME crate was linked to a data acquisition computer through an SBS 620 optical VME-PCI interface 13 that allows memory mapping of the VME resources via an open source driver. 14 The computer was equipped with a Pentium-4 2 GHz CPU, 1 GB of RAM, and running a CERN SLC 4.3 operating system. 15 The data acquisition was built around a single-event polling mechanism and performed by a readout program that was streaming physics and on-spill pedestal events into two indepen- 9 php?mod=v792&fam=vme&fun=qdc

4 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 3. Schematic (not to scale) of the experimental setup in which the BGO crystal was tested in conjunction with the DREAM fiber calorimeter. Not shown is a cm 2 scintillation counter placed 8 m downstream of the DREAM calorimeter behind a 80 cm thick concrete block, which served as a muon counter. With this scheme, we were able to reach, in spill, a data acquisition rate of 2 khz, limited by the size of the internal scope buffer. Since no pedestal suppression was implemented, the data volume was proportional to this rate, and amounted, at maximum, to 1:5MB=spill, largely dominated by the oscilloscope data Calibration of the detectors Fig. 4. Average time structure of the signals from a pion crossing a single lead tungstate crystal perpendicularly. The rise time of the signal (from 10% to 90% of the amplitude in 3.5 ns) is determined by the PMT and by the long cables (23 m) which transport the signals from the crystal to the oscilloscope, the trailing edge is determined by the PbWO 4 decay characteristics, with a dominating component of 10 ns [5]. dent first-in-first-out buffers, built on top of 32 MB shared memories. Two recorder programs were then dumping the data from the shared memories to the disk. Only exclusive accesses to shared buffers were allowed and concurrent requests were synchronized with semaphores. This scheme optimized the CPU utilization and increased the data taking efficiency thanks to the bunch structure of the SPS cycle, where beam particles were provided to our experiment during a spill of 4.8 s, with a repetition period of 16.8 s. On the other hand, due to the large oscilloscope data size and its poor on-line performance, we decided to handle it on a multievent basis. Through the GPIB interface, the digital scope was prepared to acquire events before the extraction and delivery of protons on target. On spill, all events were sequentially recorded in the internal memory of the scope. At the end of the spill, the oscilloscope memory was dumped over a temporary file, in a network-mounted shared disk. At this point, the file was read out and the data copied in properly formatted areas in the sharedmemory buffers, where the information from all the VME modules had already been stored, in real time, by the readout program. In sequence, the recorder programs were then dumping the events to disk and a monitoring program was running in spy mode, on top of the physics shared memory, producing online histograms. All PMTs used in these measurements were calibrated with 50 GeV electrons. The two PMTs reading out the two sides of the PbWO 4 crystal matrix were calibrated with the detector oriented as shown in Fig. 2. The PMTs reading out the BGO crystals were calibrated with the crystal oriented as shown in Fig. 3, and the filters in place. In both cases, longitudinal shower containment was adequate. However, lateral shower leakage was substantial in the case of BGO. According to our Monte Carlo simulations, the BGO crystal detected, on average, only 38.2 GeV of the energy carried by the beam electrons. The PbWO 4 matrix contained, on average, 47.3 GeV. The 38 PMTs reading out the 19 towers of the HCAL were also all calibrated with 50 GeV electrons. The showers generated by these particles were not completely contained in a single calorimeter tower. The (average) containment was again found from EGS4 Monte Carlo simulations. When the electrons entered a tower in its geometrical center, on average 92.5% of the scintillation light and 93.6% of the Cherenkov light was generated in that tower [2]. The remaining fraction of the light was shared by the surrounding towers. The signals observed in the exposed tower thus corresponded to an energy deposit of 46.3 GeV in the case of the scintillating fibers and of 46.8 GeV for the Cherenkov fibers. The mentioned energies, together with the precisely measured values of the average signals from the exposed crystals or calorimeter towers, formed the basis for determining the calibration constants, i.e., the relationship between the measured number of ADC counts and the corresponding energy deposit. 3. Experimental data and methods The purpose of these tests was to split the crystal signals into their scintillation and Cherenkov components, and to see to what extent this event-by-event information could be used to improve the hadronic calorimeter performance of a calorimeter system of which these crystals formed the electromagnetic section Experimental data All measurements were performed with 200 GeV p þ beams. We collected events for PbWO 4 and 1: events for

5 714 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) BGO. For each event, the time structure of both ECAL signals was measured (with 0.4 ns resolution in the case of PbWO 4, 0.8 ns for BGO). The integrated charge carried by these signals and by those from the 38 HCAL channels was digitized with 12-bit resolution. The pion beams contained some muons, at the few-% level. These muons were easily recognized (using the muon counter) and removed from the event samples. For reasons explained below, the signals from the UV side of the BGO crystal consisted of two distinctly different components. The signals from these components were separately digitized, using two different outputs of the Linear Fan-out Exploiting the BGO signals The time structure of the signals from the BGO crystal observed with the yellow filter and the UV filter were very different [6]. This is illustrated in Fig. 5, which shows the time structures measured from both sides of the crystal (i.e., with the two different filters) for a typical shower developing in it. The scintillation spectrum of BGO is centered around a wavelength of 480 nm, i.e., in the yellow/green domain. The decay time of the scintillation process is 300 ns. The yellow filter is highly transparent for this type of light, as reflected by the signal shape in Fig. 5a. The UV filter is transparent for light in the wavelength region from 250 to 400 nm, which harbors a large fraction of the Cherenkov light, and little of the scintillation light. The time structure of the signals from the PMT placed behind the UV filter (Fig. 5b) clearly exhibits these two components. The (prompt) Cherenkov component is represented by the sharp peak, whereas the long tail has the same characteristic time structure as the pure scintillation signals generated by the light transmitted through the yellow filter. The signals from the PMT that detects the light transmitted through the UV filter thus contains event-by-event information about the relative contributions of Cherenkov and scintillation photons. We have taken advantage of this feature by generating digitized signals for both components. Output signals from the Linear Fan-Out were used to generate two ADC gates, which corresponded to different time intervals (Fig. 6). Gate 1 was used to digitize the part of the signals that contained the Cherenkov peak, while gate 2 probed the scintillation component. Of course, some fraction of the scintillation light contributed to the signals from gate 1 as well. However, the pure scintillation signals from the yellow filter side made it possible to determine that fraction with great precision. Knowing that fraction, the UV signals recorded in gate 1 could thus be corrected for scintillation contributions event by event on the basis of the gate 2 signals. In this way, pure digitized Cherenkov and scintillation signals were obtained from the crystal signals observed in the UV PMT. The same information could also be extracted from the oscilloscope data. This allowed for more flexibility, since the gate boundaries could be optimized off-line. The data shown in the following were obtained with the latter method. Much more information about the characteristics of the BGO crystal, and the separation of its signals into scintillation and Cherenkov components, is given in Ref. [6]. 4. Experimental results for BGO 4.1. Calibration of the UV signal components The UV Cherenkov and scintillation signals produced by the BGO crystal were calibrated separately with 50 GeV electrons. Fig. 6. The UV BGO signals were used to measure the relative contributions of scintillation light (gate 2) and Cherenkov light (gate 1). The oscilloscope sampled the time structure at intervals of 0.8 ns in this case. See text for details. Fig. 5. The time structure of a typical shower signal measured in the BGO crystal equipped with a yellow filter (a), and with a UV filter (b). These signals were measured with a sampling oscilloscope, which took a sample every 2 ns in this case.

6 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) According to our Monte Carlo simulations, these electrons deposited, on average, 38.2 GeV in this crystal, with lateral (side) leakage being responsible for most of the lost energy. Fig. 7 shows the results of this calibration, which was carried out for the oscilloscope signals. We defined gate 1 as the integrated charge collected during the first 16 ns of the pulse, while gate 2 integrated the charge from t ¼ ns. The gate 2 (pure scintillation) signal distribution is shown in Fig. 7a. The calibration constant, which converted the measured charge to energy units, was chosen such that this distribution centered around 38 GeV. Based on the oscilloscope signals from the yellow filter PMT, we concluded that the contribution of scintillation light to the gate 1 signal amounted to 15% of the gate 2 signal. The gate 1 signals were thus corrected event by event for this contribution. Fig. 7b shows the gate 1 signal distribution before and after this correction. The calibration constant was chosen such that the latter distribution, which represents the Cherenkov component of the signals, also centered around 38 GeV. Both the scintillation and the Cherenkov signal distributions had a relative width ðs=meanþ of about 4.7%. This width was determined by fluctuations in the numbers of photoelectrons per unit deposited energy (which we will call the light yield), by fluctuations in shower leakage and by fluctuations in longitudinal shower development (which may affect the signal because of the effects of light attenuation). The numbers of photoelectrons were compatible for the two signals, and therefore a comparison of the widths of the two distributions did not make it possible to distinguish between these two sources of fluctuations. However, the distribution of the Cherenkov/scintillation ðc=sþ signal ratio, i.e., the event-by-event distribution of the ratio of the two components of the UV signals, provided more information in this respect, since it was less sensitive to the fluctuations that were unrelated to the light yield. This distribution, shown in Fig. 8, is well described by a Gaussian function, with a relative width ðs=meanþ of 6.0%. We conclude from these results that the Cherenkov light yield was at least 15 photoelectrons per GeV. 200 GeV p þ. The scintillation signal distribution for these particles is shown in Fig. 9. The logarithmic scale is needed since a large fraction of the pions traversed the BGO crystal without starting a shower. The dominant mip peak is populated by these events. The nuclear interaction length of BGO is listed as 21.8 cm. However, this interaction length concerns protons, and the value for pions is typically up to 50% larger. An interaction length of 30 cm for pions would imply that 45% of these particles traversed the 24 cm long crystal without undergoing a nuclear interaction. This is close to the observed fraction of events in the mip peak. For this study, we were interested in the pions that started a shower in the BGO crystal and deposited a significant fraction of their energy in this crystal. We have selected events that deposited GeV in the crystal (Fig. 9), where the energy 4.2. The pion signals Now that the energy scale for the UV signals from the BGO crystal is set, we focus our attention on the signals from the Fig. 8. Distribution of the Cherenkov/scintillation signal ratio for 50 GeV electrons showering in the BGO crystal. Fig. 7. Calibrated signal distributions for 50 GeV electrons in the BGO crystal. Shown are the distributions of the scintillation signals (a) and the Cherenkov signals before and after correcting for the contribution of scintillation light to the prompt component (b).

7 716 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 9. Scintillation signal distribution in the BGO crystal, for 200 GeV p þ. The energy scale is derived from the electron calibration (Fig. 7a). Events in the shaded area were selected for further analysis. Fig. 11. The Cherenkov/scintillation signal ratio of the DREAM calorimeter, for 200 GeV p þ starting a shower in the BGO crystal, as a function of the Cherenkov/ scintillation signal ratio of the BGO signal ECAL/HCAL correlation Fig. 10. Distribution of the Cherenkov/scintillation signal ratio for 200 GeV p þ that started a shower in the BGO crystal and deposited GeV in this crystal. was determined from the UV scintillation signals, on the basis of the electron calibration described above. These events represented 20% of the total, and 40% of the non-mip events. The distribution of the Cherenkov/scintillation signal ratio for the interacting pion events selected this way is shown in Fig. 10. This distribution looks very different from the equivalent one for electrons (Fig. 8). Many events exhibited Cherenkov signals that were considerably larger than the scintillation signals. The reasons for this phenomenon are discussed in detail in Section 4.4. Suffice it to say at this point that the underlying assumption of this study was that the C=S signal ratio is a measure of the p 0 production in the hadronic shower absorption process. In the next subsection, we investigate to what extent this ratio can be used to improve the hadronic performance of the calorimeter system as a whole, in the same way as we demonstrated this to be possible for the DREAM fiber calorimeter in stand-alone mode [3]. Because the BGO ECAL section of our calorimeter system was so small (less than 80% of the shower energy deposited by an electron was contained), large hadronic signals in the ECAL were likely to be caused by energetic p 0 s produced in the early stages of the shower development. Therefore, it is reasonable to expect that hadronic events in which a considerable fraction of the energy was deposited in the BGO also exhibit substantial Cherenkov signals in the HCAL. In other words, one should expect a correlation between the C=S signal ratios in both sections of the calorimeter system. Fig. 11 shows that this correlation was indeed very strong, except for events that had relatively small C=S signal ratios. Our analysis of the DREAM stand-alone data showed a strong correlation between the total hadronic calorimeter signal and the C=S signal ratio. This correlation formed the essence of the elimination of the effects of fluctuations in the em shower component, f em, on the hadronic calorimeter performance [3]. Given the correlation observed in Fig. 11, it is therefore no surprise that in the present experiment the total signal observed in the HCAL was strongly correlated with the C=S signal ratio measured in the BGO ECAL. This correlation is shown in Fig. 12a. The difference between the total signals for events with the largest and the smallest C=S signal ratios in the crystal ECAL was measured to be more than 50%. To put this result in perspective, we mention that this difference was measured to be less than 20% in a previous study, in which f em was derived from the asymmetry between the signals from the two sides of an ECAL consisting of the PbWO 4 crystal matrix shown in Fig. 1, placed at an angle maximizing the difference between the relative contributions of Cherenkov light to both signals [5]. Interestingly, the fractional width of the signal distributions observed in the HCAL decreased as the events became more electromagnetic. This is illustrated in Fig. 12b, which shows this width ðs rms =meanþ as a function of the C=S signal ratio in the crystal. It decreased from more than 30% for events with relatively small Cherenkov signals (i.e., low p 0 activity) to 12% for events with the largest C=S signal ratios. It is well known that the hadronic energy resolution of calorimeters is strongly affected by fluctuations in invisible energy (e.g., nuclear binding energy

8 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 12. The total scintillation signal (a) and the fractional width of the total scintillation signal distribution (b) in the DREAM calorimeter, for 200 GeV p þ starting a shower in the BGO crystal, as a function of the Cherenkov/scintillation signal ratio of the BGO signal. Fig. 13. The total scintillation signal distribution in the DREAM calorimeter, for 200 GeV p þ starting a shower and depositing GeV in the BGO crystal, for two different values of the Cherenkov/scintillation signal ratio of the UV BGO signals. losses) [7]. Since such fluctuations only play a role in the non-em shower component, it is no surprise to see that the resolution improves for events in which a large fraction of the available energy was converted into em shower components, compared to events for which this fraction was smaller. This result thus confirms, once again, that the event selection on the basis of the Cherenkov/scintillation signal ratio in the BGO crystal was a good measure for f em. The results of this analysis are summarized in Fig. 13, which shows the distributions of the total scintillation signal measured in the fiber HCAL for subsets of events selected on the basis of the Cherenkov/scintillation signal ratio in the BGO ECAL. The signal distribution for the events with a large C=S signal ratio is considerably narrower and peaks at a larger value than the distribution for the events with a smaller C=S signal ratio Attenuation effects There is one issue in the above analysis that remains to be addressed. The distribution of the C=S signal ratio in the BGO crystal looks very different for the pions (Fig. 10) than for the electrons with which the BGO signals were calibrated (Fig. 8). While the electron distribution is well described by a Gaussian with a mean value of 1.0, the pion distribution is highly asymmetric, and its mean value is 2.1. In this subsection, we investigate possible reasons for this difference. Contrary to the electron showers, where most of the light was produced in the first half of the crystal, the light in pion-induced showers was, on average, produced much closer to the UV PMT that generated the signals we used for this analysis. Therefore, one might suspect that differences in light attenuation for the Cherenkov and scintillation components are responsible for the observed effects. In order to assess this possibility, we also took data with the BGO crystal rotated by 901, i.e., oriented perpendicular to the beam line. Electrons of 50 GeV were sent into the crystal, which was moved in steps of 1 cm. In this way, the response of the two PMTs was measured over the full length of the crystal. The oscilloscope data collected from these measurements were analyzed in the same way as described previously for the combined ECAL/HCAL data. The UV signals were separated in two parts, covering the prompt Cherenkov peak and the scintillation tail, respectively. The contribution of scintillation light to the prompt signals was determined on the basis of the time structure of the pure scintillation signals from the PMT behind the yellow filter. The results of these measurements are summarized in Fig. 14. This figure shows that, while the overall signal in the UV PMT decreases as a function of the distance the light had to travel (Fig. 14a), the Cherenkov/scintillation signal ratio did not change much over the length of the crystal (Fig. 14b). A few comments are in order. The C=S signal ratio was somewhat smaller in these measurements than in the longitudinal geometry (Fig. 8), because of the different acceptance of the (directional) Cherenkov light in the crystal. The decrease of the total signal as a function of the distance was not only a consequence of light attenuation, but also of the tapered geometry of the crystal. As the distance to the UV PMT increased, the thickness of the crystal, and thus the amount of

9 718 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Cherenkov/scintillation ratio is considerably harder to extract because [6] (1) The scintillation light is predominantly blue. Therefore, filtering is not an option to effectively distinguish the two components in this case. (2) The decay of the PbWO 4 scintillation component is very fast, tt10 ns at room temperature [8]. Contributions from the prompt Cherenkov component are thus much harder to disentangle. Fig. 14. The total UV BGO signal (a) and the ratio of the Cherenkov and scintillation components of that signal (b) as a function of the distance from the light production region to the PMT where it is detected. Data for 50 GeV electrons traversing the crystal perpendicularly. light produced in it by the showering electrons, decreased (Fig. 3). The separate effects of attenuation and geometry on the crystal signals have been studied in detail in another paper [6]. Apparently, differences in light attenuation were thus not responsible for the different characteristics of the C=S distributions observed for pions and electrons. However, Fig. 14b does provide an important indication for the possible cause. The C=S ratio of the signals measured in the point closest to the UV PMT were anomalously high, more than a factor of 2 above average. This is due to the fact that in that case some of the shower particles traversed the glass window of the PMT and/or the filter and generated Cherenkov light (but no scintillation light) in that process. The filter/pmt combination thus served as an additional source of Cherenkov light, whenever charged relativistic shower particles traversed it. This phenomenon could also very well explain the differences observed between the electron and pion signals. Especially when the pions produce an energetic p 0 in the last 10 cm of the BGO crystal, the filter/window may be located right at the shower maximum of the em showers through which this p 0 is being absorbed, resulting in substantial additional Cherenkov signals. Since this mechanism contributes exclusively to the Cherenkov signal, it would also explain why C=S signal ratios larger than those for electron showers were observed. Nevertheless, the excellent time resolution of our experimental setup made it also possible to distinguish between the prompt Cherenkov peak and the scintillation light in this case. This is illustrated in Fig. 15, which shows the average time structure of the PbWO 4 crystal signals recorded for the 200 GeV pions in the downstream photomultiplier tube (PMT B, see Fig. 2). The Cherenkov component is clearly visible and rather well resolved from the dominating scintillation component. The oscillating pattern superimposed on the trailing edge of this pulse is most likely the result of internal reflections of the directional light component in the crystal [6]. This explanation is corroborated by a comparison of the time structures in Figs. 18a and b. In order to determine the Cherenkov fraction for individual events, we have used a method based on the fraction of the total signal that was recorded in the first 6.4 ns, f ð6:4þ. The larger this fraction, the larger the Cherenkov component of the signal [6]. This fraction (highlighted in Fig. 15) amounted typically to 17%. As in the case of BGO, about half of the pions penetrated the PbWO 4 matrix without undergoing a nuclear interaction. The Cherenkov light generated by these pions went largely undetected, since the large index of refraction prevented it from exiting the crystal. As in the case of BGO, we were predominantly interested in the pions that started a shower in the crystal matrix and deposited a significant fraction of their energy in the crystal (Fig. 9). Fig. 16 shows the distribution of f ð6:4þ for these events. As expected, the average value is significantly larger as a result of these cuts. Assuming that f ð6:4þ is a good measure for the production of Cherenkov light in individual events, we proceeded by investigating the characteristics of the signals in the hadronic fiber section in relation to the f ð6:4þ value. 5. Experimental results for PbWO 4 Even though the PbWO 4 signals contain a substantially larger fraction of Cherenkov light than those from BGO (15% at room temperature [8], vs. 51%), event-by-event information on the Fig. 15. Average time structure of the PbWO 4 signals recorded for 200 GeV p þ in the downstream PMT of the PbWO 4 ECAL. The light collected during the first 6.4 ns (16 bins) is highlighted.

10 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 17 shows the same phenomena as observed for BGO (Fig. 12). As f ð6:4þ increases, the total (scintillator) signal observed in the hadronic section increases and the energy resolution of the signal distribution in the hadronic section improves. This is exactly what one would expect as a result of an increase of the (average) electromagnetic fraction of the events. We conclude that f ð6:4þ is a good measure of the Cherenkov content of the PbWO 4 light, and thus of the em shower content. Other measures, such as the ones discussed in the previous section, confirmed that conclusion. To underscore the fact that also the signals from the PbWO 4 ECAL can be used to determine the em fraction of the showers developing in this calorimeter system, we have selected two subsamples of events with different f ð6:4þ values: 0:15of ð6:4þo 0:17 for subsample 1 and 0:35of ð6:4þo0:37 for subsample 2. These subsamples are indicated by the highlighted regions in Fig. 16. Fig. 18 shows the average time structures (a and b) as well as the distributions of the total hadronic scintillation signal for these two subsamples (c). To put the results reported in this paper into perspective, it is interesting to make a comparison with similar results previously obtained with different methods. Fig. 19b shows the effects of selecting subsamples with a different em shower fraction (Fig. 19a), based on a direct measurement of the Cherenkov/ scintillation signal ratio in the fiber calorimeter in stand-alone mode [3]. The results previously obtained with the PbWO 4 crystal matrix are shown in Figs. 19c and d. The latter analysis used the directionality of the Cherenkov light, and the asymmetry in the signals measured by two PMTs installed on opposite ends of the matrix (which was oriented at the Cherenkov angle of 631 with the beam direction) formed the basis of the measurement of the Cherenkov fraction for individual events [5]. The results obtained with the same PbWO 4 matrix in the experiments described in this paper are better than those shown in Figs. 19c and d. In addition, the new measurements, which are based on the time structure of the crystal signals, should in principle be applicable in a hermetic 4p detector, unlike the ones described in Ref. [5]. Yet, a comparison of the different results obtained with PbWO 4 and BGO indicates that the latter crystal is somewhat better suited for this type of application. Even though the BGO ECAL consisted of only one crystal, which did not even contain em showers at the 80% level, its capability to determine the Cherenkov fraction of the light generated by showering hadrons was better than for the much larger PbWO 4 matrix. The fact that the wavelength spectrum of the BGO scintillation light allowed an almost complete separation between the two different light components is of course responsible for this advantage. 6. Conclusions Fig. 16. Distribution of the fraction of the total signal collected during the first 6.4 ns, f ð6:4þ, for 200 GeV p þ depositing GeV in the PbWO 4 ECAL. The highlighted bands denote the subsamples used to make Fig. 18. We have shown that the signals from two types of crystals can be efficiently separated into Cherenkov and scintillation components. In the case of PbWO 4, this separation is accomplished on the basis of the time structure of the signals, while BGO offers Fig. 17. The total scintillation signal (a) and the fractional width of the total scintillation signal distribution (b) in the DREAM calorimeter, for 200 GeV p þ starting a shower in the PbWO 4 ECAL, as a function of the fraction of the total charge collected during the first 6.4 ns in the PbWO 4 signals.

11 720 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) Fig. 18. Average time structure for events with 0:15ofð6:4Þo0:17 (a) and 0:35of ð6:4þo0:37 (b), and the total scintillation signal distributions in the hadronic calorimeter section for both subsamples (c). Fig. 19. Total hadronic signal distribution in the DREAM fiber calorimeter, for two event samples with a different electromagnetic fraction (b,d). The em fraction was determined on the basis of the ratio of the signals measured in the quartz and scintillating fibers ðq=sþ of the calorimeter itself (a) [3] or from the directionality of the signals measured in a PbWO 4 crystal matrix installed upstream (c) [5].

12 N. Akchurin et al. / Nuclear Instruments and Methods in Physics Research A 598 (2009) in addition differences in the spectra of these components as a tool to achieve that goal. Our tests with the latter crystal indicate that the event-by-event determination of the Cherenkov component, and thus of the electromagnetic shower fraction in hadronic shower development, is of comparable quality as that achieved for the DREAM fiber calorimeter, where the two components were measured with two physically separate active media [3]. The experiments described in this paper primarily served to demonstrate the proof of principle of this technique. The crystals used in our setup, which did not even fully contain the electromagnetic showers used to calibrate their signals, were much too small for a serious quantitative assessment of the improvements in hadronic energy resolution and linearity that could be achieved, let alone for the detection of multiparticle events, which are essential for that purpose. Our next goal is therefore to assemble a BGO ECAL with the same lateral dimensions as the fiber module, which should enable us to make such an assessment. Acknowledgments We thank CERN for making particle beams of excellent quality available. This study was carried out with financial support of the United States Department of Energy, under Contract DE-FG02-07ER References [1] R. Wigmans, et al., New J. Phys. 10 (2008) [2] N. Akchurin, et al., Nucl. Instr. and Meth. A 536 (2005) 29. [3] N. Akchurin, et al., Nucl. Instr. and Meth. A 537 (2005) 537. [4] N. Akchurin, et al., Nucl. Instr. and Meth. A 533 (2004) 305. [5] N. Akchurin, et al., Nucl. Instr. and Meth. A 584 (2008) 273. [6] N. Akchurin, et al., Nucl. Instr. and Meth. A 595 (2008) 359. [7] R. Wigmans, Calorimetry energy measurement in particle physics, International Series of Monographs on Physics, vol. 107, Oxford University Press, Oxford, [8] N. Akchurin, et al., Nucl. Instr. and Meth. A 593 (2008) 530.

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 610 (2009) 488 501 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 595 (2008) 359 374 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Dual-readout calorimetry with lead tungstate crystals

Dual-readout calorimetry with lead tungstate crystals Nuclear Instruments and Methods in Physics Research A 584 (2008) 273 284 www.elsevier.com/locate/nima Dual-readout calorimetry with lead tungstate crystals N. Akchurin a, L. Berntzon a, A. Cardini b, R.

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 621 (2010) 212 221 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 604 (2009) 512 526 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Measurement of the neutron fraction event-byevent

Measurement of the neutron fraction event-byevent Journal of Physics: Conference Series Measurement of the neutron fraction event-byevent in DREAM To cite this article: John Hauptman et al 2011 J Phys: Conf Ser 293 012080 Related content - The new RD52

More information

New Results from the DREAM project

New Results from the DREAM project New Results from the DREAM project Evelin Meoni IFAE Barcelona (UAB) On behalf of the DREAM Collaboration 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD10) 7-10 June 2010 Siena,

More information

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution

More information

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere Richard WIGMANS Department of Physics, Texas Tech University, Lubbock TX 79409-1051, USA (wigmans@ttu.edu) Abstract Cosmic ray experiments

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 640 (2011) 91 98 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal

Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal 1 Assessment of the Čerenkov light produced in a PbWO 4 crystal by means of the study of the time structure of the signal L. Cavallini, C. Mancini, A. Mecca and D. Pinci Università La Sapienza and INFN

More information

Measurement of the contribution of neutrons to hadron calorimeter signals

Measurement of the contribution of neutrons to hadron calorimeter signals ARTICLE IN PRESS Nuclear Instruments and Methods in Physics Research A 581 (2007) 643 650 www.elsevier.com/locate/nima Measurement of the contribution of neutrons to hadron calorimeter signals N. Akchurin

More information

Dual readout with tiles for calorimetry.

Dual readout with tiles for calorimetry. Dual readout with tiles for calorimetry. F.Lacava on behalf of the RD52 / DREAM Collaboration Cagliari Cosenza Iowa State Pavia Pisa Roma 1 Texas Tech. 13th Topical Seminar on Innovative Particle and Radiation

More information

Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section

Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section Silvia Franchino, Università and INFN Pavia On behalf of the DREAM collaboration Cagliari- Cosenza - Iowa State - Pavia- Pisa - Roma1 - Texas Tech Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic

More information

Contributions of Cherenkov light to the signals from lead tungstate crystals

Contributions of Cherenkov light to the signals from lead tungstate crystals Nuclear Instruments and Methods in Physics Research A 582 (2007) 474 483 www.elsevier.com/locate/nima Contributions of Cherenkov light to the signals from lead tungstate crystals N. Akchurin a, L. Berntzon

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 735 (2014) 130 144 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 735 (2014) 120 129 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

G. Gaudio, M. Livan The Art of Calorimetry Lecture V. The state of art Towards ILC calorimetry

G. Gaudio, M. Livan The Art of Calorimetry Lecture V. The state of art Towards ILC calorimetry G. Gaudio, M. Livan The Art of Calorimetry Lecture V The state of art Towards ILC calorimetry 1 Important calorimeter features Energy resolution Position resolution (need 4-vectors for physics) Particle

More information

Muon detection with a dual-readout calorimeter

Muon detection with a dual-readout calorimeter Nuclear Instruments and Methods in Physics Research A 533 (2004) 305 321 www.elsevier.com/locate/nima Muon detection with a dual-readout calorimeter N. Akchurin a, K. Carrell a, J. Hauptman b, H. Kim a,

More information

Comparison of high-energy electromagnetic shower profiles measured with scintillation and Cherenkov light

Comparison of high-energy electromagnetic shower profiles measured with scintillation and Cherenkov light Nuclear Instruments and Methods in Physics Research A 548 (2005) 336 354 www.elsevier.com/locate/nima Comparison of high-energy electromagnetic shower profiles measured with scintillation and Cherenkov

More information

Comparison of high-energy hadronic shower profiles measured with scintillation and Cherenkov light

Comparison of high-energy hadronic shower profiles measured with scintillation and Cherenkov light Nuclear Instruments and Methods in Physics Research A 584 (2008) 304 318 www.elsevier.com/locate/nima Comparison of high-energy hadronic shower profiles measured with scintillation and Cherenkov light

More information

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration 1 Dual Readout Method! Addresses the limiting factors of the resolution

More information

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS 1 PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS P.KRIEGER Department of Physics, University of Toronto, Toronto, Ontario M5S 1A7, Canada E-mail: krieger@physics.utoronto.ca A

More information

On the limits of the hadronic energy resolution of calorimeters. CALOR 2018, Eugene, May

On the limits of the hadronic energy resolution of calorimeters. CALOR 2018, Eugene, May On the limits of the hadronic energy resolution of calorimeters Sehwook Lee (KNU), Michele Livan (Pavia), Richard Wigmans (TTU) CALOR 2018, Eugene, May 22 2018 1 stream of events, in which atoms of the

More information

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1 Time Structure in Dual Readout Calorimeters Michele Cascella (UCL) for the RD52 Collaboration m.cascella@ucl.ac.uk 1 Motivation Sehwook should have convinced you that dual readout is a good idea You need

More information

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS L. E. PRICE Bldg 362, Argonne National Laboratory, Argonne, IL 60439, USA E-mail: lprice@anl.gov (For the ATLAS Tile Calorimeter Collaboration)

More information

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy Frascati Physics Series Vol. 58 (2014) Frontier Objects in Astrophysics and Particle Physics May 18-24, 2014 High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter F. Pilo for the

More information

Fig. 11. Signal distributions for 20 GeV * particles. Shown are the measured Éerenkov (a) and scintillation (b) signal distributions as well as the

Fig. 11. Signal distributions for 20 GeV * particles. Shown are the measured Éerenkov (a) and scintillation (b) signal distributions as well as the Fig. 11. Signal distributions for 20 GeV * particles. Shown are the measured Éerenkov (a) and scintillation (b) signal distributions as well as the signal distribution obtained by combining the two signals

More information

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2 Prepared for submission to JINST Calorimetry for the High Energy Frontier -6 October 17 Lyon (France) Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run Leonor Cerda Alberich,

More information

Validation of Geant4 Physics Models Using Collision Data from the LHC

Validation of Geant4 Physics Models Using Collision Data from the LHC Journal of Physics: Conference Series Validation of Geant4 Physics Models Using Collision from the LHC To cite this article: S Banerjee and CMS Experiment 20 J. Phys.: Conf. Ser. 33 032003 Related content

More information

A gas-filled calorimeter for high intensity beam environments

A gas-filled calorimeter for high intensity beam environments Available online at www.sciencedirect.com Physics Procedia 37 (212 ) 364 371 TIPP 211 - Technology and Instrumentation in Particle Physics 211 A gas-filled calorimeter for high intensity beam environments

More information

ATLAS Hadronic Calorimeters 101

ATLAS Hadronic Calorimeters 101 ATLAS Hadronic Calorimeters 101 Hadronic showers ATLAS Hadronic Calorimeters Tile Calorimeter Hadronic Endcap Calorimeter Forward Calorimeter Noise and Dead Material First ATLAS Physics Meeting of the

More information

Simulation and validation of the ATLAS Tile Calorimeter response

Simulation and validation of the ATLAS Tile Calorimeter response Home Search Collections Journals About Contact us My IOPscience Simulation and validation of the ATLAS Tile Calorimeter response This content has been downloaded from IOPscience. Please scroll down to

More information

arxiv: v1 [physics.ins-det] 15 Dec 2017

arxiv: v1 [physics.ins-det] 15 Dec 2017 DUAL-READOUT CALORIMETRY Sehwook Lee Department of Physics, Kyungpook National University, Daegu, Korea Michele Livan Dipartimento di Fisica, Università di Pavia and INFN Sezione di Pavia, Via Bassi 6,

More information

Electromagnetic and hadronic showers development. G. Gaudio, M. Livan The Art of Calorimetry Lecture II

Electromagnetic and hadronic showers development. G. Gaudio, M. Livan The Art of Calorimetry Lecture II Electromagnetic and hadronic showers development 1 G. Gaudio, M. Livan The Art of Calorimetry Lecture II Summary (Z dependence) Z Z 4 5 Z(Z + 1) Z Z(Z + 1) 2 A simple shower 3 Electromagnetic Showers Differences

More information

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS, For the Belle II PID group KMI, Nagoya University E-mail: matsuoka@hepl.phys.nagoya-u.ac.jp The TOP (Time-Of-Propagation) counter

More information

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment Roberto Gemme Università del Piemonte Orientale A. Avogadro (Alessandria) on behalf of the ALICE Collaboration Outline

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 602 (2009) 489 493 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 62 (29) 52 524 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance arxiv:1812.00594v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance Alla Maevskaya for the ALICE collaboration 1, 1 Institute

More information

Hands on Project: Large Photocathode PMT Characterization

Hands on Project: Large Photocathode PMT Characterization Hands on Project: Large Photocathode PMT Characterization Rickard Stroem Dept. of Physics and Astronomy, Uppsala University E-mail: rickard.strom@physics.uu.se Institute of Cosmic Ray Research, University

More information

Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT

Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT Summary Theoretical and experimental foundations of high resolution hadron calorimetry

More information

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona LHCb 2000-32, CALO 9 June 2000 Results of a tagged photon test beam for the Scintillator Pad Detector. Llu s Garrido David Gascón Ramon Miquel Daniel Peralta Universitat de Barcelona, ECM department E-08028

More information

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis) ATLAS EXPERIMENT : HOW THE DATA FLOWS (Trigger, Computing, and Data Analysis) In order to process large volumes of data within nanosecond timescales, the trigger system is designed to select interesting

More information

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006 CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 6 C. Cârloganu and A.-M. Magnan on behalf of the CALICE Collaboration - LPC Clermont-Ferrand, INP3/CNRS, UBP, France - Imperial College

More information

First results from the NEMO Phase 1 experiment

First results from the NEMO Phase 1 experiment First results from the NEMO Phase 1 experiment Isabella Amore a,b for the NEMO Collaboration a Dipartimento di Fisica e Astronomia, Università di Catania, Italy b INFN Laboratori Nazionali del Sud, Catania,

More information

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment Camilla Vittori Department of Physics, University of Bologna, Italy Summer Student Program 2014 Supervisor

More information

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington University of Texas, Arlington E-mail: brandta@uta.edu A brief description of the ATLAS forward detectors is given. XVIII International Workshop on Deep-Inelastic Scattering and Related Subjects April

More information

The electromagnetic calorimeter of the HERA-B experiment

The electromagnetic calorimeter of the HERA-B experiment Nuclear Instruments and Methods in Physics Research A 446 (2000) 246}252 The electromagnetic calorimeter of the HERA-B experiment A. Zoccoli For the HERA-B Collaboration Dipartimento di Fisica, Universita%

More information

Physics sources of noise in ring imaging Cherenkov detectors

Physics sources of noise in ring imaging Cherenkov detectors Nuclear Instruments and Methods in Physics Research A 433 (1999) 235}239 Physics sources of noise in ring imaging Cherenkov detectors For the ALICE HMPID Group Andreas Morsch EP Division, CERN, CH-1211

More information

Upgrade of the CMS Forward Calorimetry

Upgrade of the CMS Forward Calorimetry Upgrade of the CMS Forward Calorimetry Riccardo Paramatti Cern & INFN Roma IPMLHC2013 Tehran 9 th October Credits to Francesca Cavallari and Pawel de Barbaro Outline Radiation damage at HL-LHC ECAL and

More information

Advances in the Micro-Hole & Strip Plate gaseous detector

Advances in the Micro-Hole & Strip Plate gaseous detector Nuclear Instruments and Methods in Physics Research A 504 (2003) 364 368 Advances in the Micro-Hole & Strip Plate gaseous detector J.M. Maia a,b,c, *, J.F.C.A. Veloso a, J.M.F. dos Santos a, A. Breskin

More information

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce F.C.L. Crespi 1,2, F.Camera 1,2, N. Blasi 2, A.Bracco 1,2, S. Brambilla 2, B. Million 2, R. Nicolini 1,2, L.Pellegri 1, S. Riboldi

More information

A Complete Simulation of a Triple-GEM Detector

A Complete Simulation of a Triple-GEM Detector 1638 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 4, AUGUST 2002 A Complete Simulation of a Triple-GEM Detector W. Bonivento, A. Cardini, G. Bencivenni, F. Murtas, and D. Pinci Abstract Since some

More information

Calorimetry in particle physics experiments

Calorimetry in particle physics experiments Calorimetry in particle physics experiments Unit N. 9 The NA48 ECAL example (LKR) Roberta Arcidiacono R. Arcidiacono Calorimetry 1 Lecture overview The requirements Detector layout & construction Readout

More information

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements B. Bilki 1,2,3, B. Freund 4, Y. Onel 1, J. Repond 3 1 University of Iowa, Iowa City, USA 2 Beykent University,

More information

A fast triple GEM detector for high-rate charged-particle triggering

A fast triple GEM detector for high-rate charged-particle triggering Nuclear Instruments and Methods in Physics Research A 478 (2002) 245 249 A fast triple GEM detector for high-rate charged-particle triggering G. Bencivenni a, W. Bonivento b,1, C. Bosio c, A. Cardini b,

More information

Information about the T9 beam line and experimental facilities

Information about the T9 beam line and experimental facilities Information about the T9 beam line and experimental facilities The incoming proton beam from the PS accelerator impinges on the North target and thus produces the particles for the T9 beam line. The collisions

More information

The HERA-B ring imaging Cherenkov system } design and performance

The HERA-B ring imaging Cherenkov system } design and performance Nuclear Instruments and Methods in Physics Research A 446 (2000) 299}304 The HERA-B ring imaging Cherenkov system } design and performance JoK rg Pyrlik For the HERA-B RICH Collaboration University of

More information

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Digital Hadron Calorimetry for the Linear Collider using GEM Technology Digital Hadron Calorimetry for the Linear Collider using GEM Technology University of Texas at Arlington Andrew Brandt, Kaushik De, Shahnoor Habib, Venkat Kaushik, Jia Li, Mark Sosebee, Andy White* 1,

More information

Available online at Physics Procedia 37 (2012 )

Available online at   Physics Procedia 37 (2012 ) Available online at www.sciencedirect.com Physics Procedia 37 (2012 ) 229 237 TIPP 2011 - Technology and Instrumentation for Particle Physics 2011 The ATLAS Tile Hadronic Calorimeter performance in the

More information

arxiv:hep-ex/ v1 7 Oct 1999

arxiv:hep-ex/ v1 7 Oct 1999 HADRONIC SHOWER DEVELOPMENT IN TILE IRON-SCINTILLATOR CALORIMETRY arxiv:hep-ex/9905v 7 Oct 999 Y.A. KULCHITSKY for TILECAL Collaboration JINR, Dubna, Russia & IP National Academy of Science, Minsk, Belarus

More information

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl Introduction - Purpose of CPV: veto Kl decay modes with a real or apparent π and a pair of charged particles - Examples of background modes: (i) K l π π + π (ii) K l π π ± eν there are always (iii) K l

More information

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons uclear Instruments and Methods in Physics Research A 567 (26) 124 128 www.elsevier.com/locate/nima Tests of the Burle 8511 64-anode MCP PMT as a detector of Cherenkov photons P. Krizˇan a,b,, I. Adachi

More information

GEM-based photon detector for RICH applications

GEM-based photon detector for RICH applications Nuclear Instruments and Methods in Physics Research A 535 (2004) 324 329 www.elsevier.com/locate/nima GEM-based photon detector for RICH applications Thomas Meinschad, Leszek Ropelewski, Fabio Sauli CERN,

More information

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008 1 2 3 4 First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 28 The CALICE collaboration November 22, 29 5 6 7 8 9 11 12 13 14 This note contains

More information

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter Yifeng Wei, Zhiyong Zhang, Yunlong Zhang*, Sicheng Wen, Chi Wang, Zhiying Li, Changqing Feng, Xiaolian Wang,

More information

CALICE Test Beam Data and Hadronic Shower Models

CALICE Test Beam Data and Hadronic Shower Models EUDET CALICE Test Beam Data and Hadronic Shower Models Riccardo Fabbri on behalf of the CALICE Collaboration FLC, DESY, Notkestrasse 85, 67 Hamburg, Germany Email: Riccardo.Fabbri@desy.de January 1, 1

More information

What detectors measure

What detectors measure What detectors measure As a particle goes through matter, it releases energy Detectors collect the released energy and convert it to electric signals recorded by DAQ Raw event record is a collection of

More information

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7! Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEAUREMENT PROCEDURE...3! III. ANALYI PROCEDURE...7! Revised July 2011 I. Introduction In this experiment you will measure the

More information

Calorimetry in. in Nuclear and Particle Physics Experiments

Calorimetry in. in Nuclear and Particle Physics Experiments 1 Calorimetry in in Nuclear and Particle Physics Experiments QuickTime and a TIFF (Uncompressed) decompressor are needed to see this picture. Outline 2 Electromagnetic showers Hadronic showers Electromagnetic

More information

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT 9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT Students: Riccardo Falcione, Elisa Paris Liceo Scientifico Statale Farnesina Tutor:

More information

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2 Photons Produced in PbF 2 R. Dolenec a, S. Korpar b,a, P. Križan c,a, R. Pestotnik a, A. Stanovnik d,a a, Ljubljana, Slovenia b Faculty of Chemistry and Chemical Engineering, University of Maribor, Slovenia

More information

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo ICEPP, the University of Tokyo E-mail: sawada@icepp.s.u-tokyo.ac.jp The MEG experiment yielded the most stringent upper limit on the branching ratio of the flavorviolating muon decay µ + e + γ. A major

More information

A measurement of the air fluorescence yield

A measurement of the air fluorescence yield Nuclear Instruments and Methods in Physics Research A 372 (1996) 527-533 A measurement of the air fluorescence yield F. Kakimoto a, E.C. Loh b, M. Nagano c.*, H. Okuno d, M. Teshima c, S. Ueno a a Department

More information

Geant4 simulations of the lead fluoride calorimeter

Geant4 simulations of the lead fluoride calorimeter Geant4 simulations of the lead fluoride calorimeter A.A. Savchenko a, *, A.A. Tishchenko a, S.B. Dabagov a,b, A. Anastasi b,c, G. Venanzoni b, M.N. Strikhanov a (et al.) a National Research Nuclear University

More information

Future prospects for the measurement of direct photons at the LHC

Future prospects for the measurement of direct photons at the LHC Future prospects for the measurement of direct photons at the LHC David Joffe on behalf of the and CMS Collaborations Southern Methodist University Department of Physics, 75275 Dallas, Texas, USA DOI:

More information

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond MINOS Physics Program and Construction Status Karol Lang The University of Texas at Austin YITP: Neutrinos and Implications for Physics Beyond YITP Conference: Neutrinos and Implications The Standard for

More information

Scintillation Detector

Scintillation Detector Scintillation Detector Introduction The detection of ionizing radiation by the scintillation light produced in certain materials is one of the oldest techniques on record. In Geiger and Marsden s famous

More information

PoS(PhotoDet 2012)010

PoS(PhotoDet 2012)010 Study on Large Area Photomultipliers with Super Bialkali Photocathode 1 Sebastiano Aiello Domenico Lo Presti, Dipartimento di Fisica ed Astronomia di Catania Valentina Giordano Fabio Longhitano Cristina

More information

arxiv:physics/ v1 3 Aug 2006

arxiv:physics/ v1 3 Aug 2006 Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon arxiv:physics/6834 v1 3 Aug 26 K. Ni, E. Aprile, K.L. Giboni, P. Majewski, M. Yamashita Physics Department and Columbia Astrophysics Laboratory

More information

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010) Physics Notebook - 2010 Steve Sekula's Analysis Notebook Physics Notebook - 2010 Steve Sekula's Analysis Notebook Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created

More information

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group Introduction Construction, Integration and Commissioning on the Surface Installation

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 712 (2013) 8 112 Contents lists available at SciVerse ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

The Electromagnetic Calorimeter of the HERA-B Experiment

The Electromagnetic Calorimeter of the HERA-B Experiment 1 The Electromagnetic Calorimeter of the HERA-B Experiment B.Giacobbe a a I.N.F.N Bologna, Via Irnerio 46, 40127 Bologna, Italy At the end of the HERA-B data taking, an overview of the experiment s Electromagnetic

More information

THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT

THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT SF2A 2012 S. Boissier, P. de Laverny, N. Nardetto, R. Samadi, D. Valls-Gabaud and H. Wozniak (eds) THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT M. Vecchi 1, L. Basara 2, G. Bigongiari 3, F.

More information

THE main physics motivation for building the Compact

THE main physics motivation for building the Compact 1560 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 4, AUGUST 2004 Precision Lead Tungstate Crystal Calorimeter for CMS at LHC Ren-Yuan Zhu, Senior Member, IEEE Abstract A precision lead tungstate

More information

CMS ECAL status and performance with the first LHC collisions

CMS ECAL status and performance with the first LHC collisions CMS ECAL status and performance with the first LHC collisions XIV International Conference on Calorimetry in High Energy Physics (Calor 2010) Konstantinos Theofilatos (ETH Zurich) on behalf of CMS ECAL

More information

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Calibration of the CMS Electromagnetic Calorimeter with first LHC data IPRD10 Siena, June 7-10 2010 1 Calibration of the CMS Electromagnetic Calorimeter with first LHC data Maria Margherita Obertino (Universita del Piemonte Orientale INFN Torino) On behalf of the CMS Collaboration

More information

ATLAS Tile Calorimeter performance for single particles in beam tests

ATLAS Tile Calorimeter performance for single particles in beam tests Journal of Physics: Conference Series ATLAS Tile Calorimeter performance for single particles in beam tests To cite this article: T Davidek and the Atlas Tilecal system 2009 J. Phys.: Conf. Ser. 160 012057

More information

Status of the CALICE analog calorimeter technological prototypes

Status of the CALICE analog calorimeter technological prototypes Status of the CALICE analog calorimeter technological prototypes Mark Terwort on behalf of the CALICE collaboration DESY, Notkestrasse 85, 22607 Hamburg, Germany E-mail: mark.terwort@desy.de Abstract.

More information

Performance of New and Upgraded Detectors for Luminosity and Beam Condition Measurement at CMS

Performance of New and Upgraded Detectors for Luminosity and Beam Condition Measurement at CMS Performance of New and Upgraded Detectors for Luminosity and Beam Condition Measurement at CMS Jessica Leonard On behalf of CMS BRIL EPS 2015, Vienna July 24, 2015 1 CMS BRIL: Beam Radiation Instrumentation

More information

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements AIM AIM Discovery of New High Mass Particles Requirements Centre-of-Mass energy > 1000GeV High Coverage Study of Rare Interactions Requirements Energy 500GeV High precision Lots of events (high luminosity)

More information

Interaction of particles in matter

Interaction of particles in matter Interaction of particles in matter Particle lifetime : N(t) = e -t/ Particles we detect ( > 10-10 s, c > 0.03m) Charged particles e ± (stable m=0.511 MeV) μ ± (c = 659m m=0.102 GeV) ± (c = 7.8m m=0.139

More information

A pattern recognition method for the RICH-based HMPID detector in ALICE

A pattern recognition method for the RICH-based HMPID detector in ALICE Nuclear Instruments and Methods in Physics Research A 433 (1999) 262}267 A pattern recognition method for the RICH-based HMPID detector in ALICE For the ALICE HMPID group and Collaboration D. Elia*, N.

More information

HIGH RESOLUTION HADRON CALORIMETRY

HIGH RESOLUTION HADRON CALORIMETRY HIGH RESOLUTION HADRON CALORIMETRY Adam Para, Fermilab Tsinghua University May 30, 2012 PART 1: Why is Hadron Calorimetry Important? Interesting? 2 1.A Recent Past: Di-jet Mass Distribution in CDF Notice:

More information

arxiv: v2 [nucl-ex] 6 Oct 2008

arxiv: v2 [nucl-ex] 6 Oct 2008 he ime Projection Chamber for the ALICE Experiment C. Lippmann and the ALICE PC Collaboration CERN, 1211 Geneva 23, Switzerland he ime Projection Chamber of the ALICE Experiment has been installed in the

More information

Reconstruction in Collider Experiments (Part IV)

Reconstruction in Collider Experiments (Part IV) Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments (Part IV) Peter Loch University of Arizona Tucson,

More information

The CMS ECAL Laser Monitoring System

The CMS ECAL Laser Monitoring System The CMS ECAL Laser Monitoring System Adolf Bornheim California Institute of Technology, 1200 East California Blvd., Pasadena, CA 91125, USA Abstract. The CMS detector at LHC will be equipped with a high

More information

Hadronic Calorimetry

Hadronic Calorimetry Hadronic Calorimetry Urs Langenegger (Paul Scherrer Institute) Fall 2014 ALEPH hadronic showers compensation detector effects neutron detection Hadronic showers simulations 50 GeV proton into segmented

More information