Short-Period Air Sampling by Direct-reading Instruments

Size: px
Start display at page:

Download "Short-Period Air Sampling by Direct-reading Instruments"

Transcription

1 Short-Period Air Sampling by Direct-reading Instruments OHAO Meeting, Toronto, October 13, 2011 Ian Drummond and Paul Bozek, Dalla Lana School of Public Health, University of Toronto

2 Program for today's talk An Overview of the concept The results of this particular project A standardized method for using a DRI Accuracy and precision of the method A standardized evaluation of DRI results Further developments

3 The Overall Objective of the Project To simplify measurement of short-period exposure to chemicals so that it may be routinely and cheaply measured at the same time as a full-shift measurement is made. How cheaply? Why make measurements routinely? How?

4 How Cheaply? When compared to a TWA survey No extra field visits or field time needed. No extra disruption of the worker No extra laboratory charges If a $5,000 instrument is used for 3 years, measures 50 shifts per year $33 per shift $1 per 15 minute period

5 Why measure routinely? Most chemicals have a short-period OEL Ceiling STEL in conjunction with TWA Excursion in conjunction with TWA Complaints about chemical exposures are often associated with short, intense episodes Capturing the whole shift gives representative, not "worst-case", short-period data

6 Why measure routinely (2)? Better understanding of workplace conditions Evaluations of controls Short-period data will identify time and location Evaluation of variability of exposure Between people, tasks, production volume, etc. Anticipation of changes to exposure standards Beryllium and the US Dept of Energy

7 Beryllium 1996 the Beryllium TWA TLV was 2 µg/m a STEL of 10 µg/m 3 was added The US DOE had no idea if it met the new standard despite several thousand personal TWA samples R.M.Tuggle, Appl.Occup.Environ.Hyg. 15(4): , 2000 The STEL standard was unexpectedly stringent

8 Why measure routinely (3)? Research technology Solvents can reach the brain in as little as 2 minutes after exposure starts. This is possibly associated with headache. To address such issues, standardized, accurate methods of short-period measurement are needed, along with a lot of data (Think, "Cheap"!)

9 How to make Short-period measurements? What is the current method for organic vapours? Alternative methods using directreading instruments (DRIs) Photoionization detectors Barriers to use of alternative methods

10 Current method to measure Short-periods for organic vapours Pump and absorbent tube 15 minute samples for STELs Up to 30 minutes for excursions As short as possible for Ceilings Expensive (many samples) Intrusive (stop work to change tubes) Not representative (worst case scenarios) Specified in Govt. regulation

11 Alternative Method Direct-reading instruments Photoionization Detectors Stable Sensitive Respond to a wide range of materials Record measurements all shift Not selective Need specific calibration for specific materials Interferences are common Positive, other organic materials Negative, humidity, methane

12 Barriers to Adoption of DRIs The existence of a method (pump & tube) specified by Govt. regulation Positive and negative interferences Lack of standardized methods of use Measurement frequency and averaging time, in particular Lack of accessible statistical tools to evaluate exposure DRIs can produce thousands of data-points

13 Overcoming the Barriers Develop a standardized method (The C-tube correction method) to improve selectivity and accuracy of PIDs On-the-fly calibration of PIDs, I.Drummond Am.Ind.Hyg.Assoc.J. 58(11), , 1997 Compare the accuracy and precision of the PID method to the pump & tube method. Provide a method to evaluate results

14 The Basic Procedure 1. Make a TWA measurement using the standard pump-and-tube method 2. For exactly the same period, use a PID to record measurements 3. Calculate C-tube correction factor CF 1. CF = TWA (Pump/tube) / TWA PID 4. Correct individual PID measurements 5. Calculate 15 min average values for the workshift

15 Project procedures Styrene test material TWA 20 ppm; STEL 40 ppm Use a sequential sampler to collect eight 15 min. pump-and-tube samples for two-hour periods Use four PID-and-TWA samplers to measure the same 8 x 15 minute periods Two MiniRae 2000 and Two ToxiRae units Five runs in the laboratory and 15 runs in a workplace making plastics Acetone present as a clean-up solvent

16 The Laboratory

17 Results in the Laboratory Run 5, Time adjusted :19:12 16:48:00 17:16:48 17:45:36 18:14:24 18:43:12 19:12:00 19:40:48

18 Laboratory Results When the PID is calibrated using isobutylene as the standard, to convert to Styrene values use either: The manufacturer's documented value of 0.40 The C-tube correction factor derived from the simultaneous TWA sample For each 15 minute period the PID value was divided by the corresponding pump-and-tube value, giving an expected value of 1.00

19 Comparison of PID with Pump-and-tube in Laboratory in constant levels of styrene Manufacturer response 0.40 C-tube correction Mean Value Std.Dev No. samples

20 Comparison of PID with Pump-and-tube in Workplace with acetone present Manufacturer response 0.40 C-tube correction Mean Value Std.Dev No. samples

21 Conclusion on short-period measurement by PID By its self, a PID does not have adequate accuracy and precision. By use of the C-tube correction, accuracy is equivalent to pump-and-tube methods. Precision is equivalent in the laboratory. In the field, precision is lower, but the much larger quantity of data will compensate

22 Standardized procedure for short-period measurements Important timing parameters The instrument response time Characteristic of the PID The frequency of measurement Under control of the experimenter The desired sample averaging time Determined by the exposure standard

23 Instrument response time Often expressed by manufacturers as "time to 90% response" Implication is, "faster is better" Can be modeled as exponential rise and fall to a step change in air concentration. Example Miran 1A IR analyzer

24 Miran 1A flow characteristics Cell volume = 5.4 litres Sample flow = 2 l/min Using ventilation terminology Air-changes per sec = sec -1

25 Miran 1A response time The average residence time for air in the cell is 1 / (air-changes per sec) = 1 / = 162 seconds The air entering the cell is physically averaged by mixing inside the cell A reading from a Miran 1A looks back in time for 162 seconds The instrument response time of the Miran 1A is 162 seconds.

26 Evaluation of other instruments The technique of challenging an instrument with a step-change in air concentration is widely applicable All direct-reading instruments have a characteristic response time, and hence look back in time when making a measurement

27 Evaluation of PID response time ToxiRae 4273, 6th challenge Calculated Actual

28 Measured Response Times The equation of the rising trace is: C = C o ( 1 e -kt ) The instrument response time is 1/k MiniRae 2000 ToxiRae 0.5 seconds 2.5 seconds Electrochemical approx. 20 seconds Miran IR 162 seconds Colorimetric tubes have a sample averaging time of approx. 60 seconds per stroke

29 The measurement frequency DRIs might make measurements at time increments that are: Less than the instrument response time Over-sampling the signal Greater than the response time Under-sampling the signal The Nyquist rate is best Sample twice during every instrument response time (just like digitizing an audio signal)

30 Sample averaging time The desired sample averaging time is determined by the exposure standard to be used for comparison Multiple readings from a DRI, covering the desired time, must be averaged Some instruments have a setting to do such averaging internally, saving only the averaged value Under-sampled data will be more variable than over-sampled data

31 The effect of different averaging times The effect of averaging blocks of data is illustrated in the following lognormal probability plot The Geometric mean increases The Geo.std.dev. decreases The mean necessarily stays the same The starting data-set is lognormally distributed with GM = 1 and GSD = 2.713

32 The effect of averaging blocks of data, N = 1, 2, 8 and

33 How to compare two different instruments If a Minirae and ToxiRae made a series of simultaneous measurements Because the instrument response times differ by a factor of 5 The GMs would differ by a factor of 1.5 The GSDs would differ by a factor of 0.6 The mean values would be the same They would predict a different probability of exceeding a given limit (95% percentile)

34 How to compare two different instruments (2) To get comparable results, the sample averaging times MUST be the same 1. Set the instrument to record data at intervals equal to half the instrument response time (or faster). 2. Calculate the average value corresponding to the exposure standard

35 Sound-level meters An example of an instrument with a well-defined response time is a soundlevel meter (slow and fast settings). It would not be possible to get comparable readings from meters with different response times We are re-discovering this effect for chemical sensors.

36 How to analyze field data? Run 6, Time adjusted :43:12 13:12:00 13:40:48 14:09:36 14:38:24 15:07:12 15:36:00

37 Convert it to this! Instrument response factor 3.00E-01 calculated on "raw data" sheet Enter 8-h TWA for substance ppm Enter 15 min STEL ppm No. logging periods in 15 mins 180 Note: Check this calculated value against the actual sample period % STEL ToxiRae 4273 Run 6 and Time :15 13:30 13:45 14:00 14:15 14:30 14:45 15:00 15:15 15:30 15:45 16:00 16:15 16:30 16:45 17:00 17:15 17:30 17:45 18:00 18:15 18:30 18:45 19:00 19:15 19:30 19:45 20:00 20:15 20:30 20:45 21:00 Start of graph is time shifted forward by 0 minutes "ctrl a" to shift phase of graph by +120 o ppm is the 8-hour TWA (assuming no exposure in unmonitored periods) 0 15 Minute period exceeds the STEL 1 15 Minute periods exceeds the 8-h TWA OEL value 0 Periods less than 1 h between periods exceeding the 8-h TWA value

38 One Page with all the information you need! The C-tube TWA value Measured by the NIOSH method The calculated 8-hour TWA value The 4 criteria STEL evaluation Failed criteria are highlighted in red The ability to shift the 15 minute periods by 5 or 10 minutes

39 Excursions and Ceilings Similar one-page analysis exists for analyzing data against excursion limits and ceiling limits However. The ACGIH TLVs do not specify the sample averaging time for excursions and ceilings

40 Excursions Based on a careful reading of the scientific literature, and discussion, we are using the following definition Excursions in worker exposure levels may exceed 3 times the TLV-TWA for no more than two 15-minute periods during a workday, and under no circumstances should any 15-minute period exceed 5 times the TLV- TWA, provided the TLV-TWA is not exceeded.

41 Ceiling Limits Historically grab samples were used Pump and tube 10 min Colorimetric detector tubes 1 min Electrochemical cells 30 seconds Physiologically One breath 10 seconds Brain clearance half-life 1 minute

42 Ceiling Limit averaging time The criterion for evaluation is that no one minute period during the work-day should exceed the Ceiling OEL. PLEASE, do not use an instrument to evaluate ceiling exposures without knowing the instrument response time

43 Documentation Report on WSIB Project #09025 Includes step-by-step Guidelines for use of DRIs and charcoal tubes to simultaneously measure TWA and shortperiod exposures Excel spreadsheet for analysis of data References Details of the sequential sampler

44 Further work We don't know how to predict the probability of exceeding a STEL We don't know under what conditions the 8-hr TWA or the short-period limit is more controlling Why two standards for different times? We can't predict exposures at one time from data taken at a different averaging time Hence the Beryllium example where adding a STEL to a TWA had an unknown effect

45 How to address these questions? A robust statistical model of short-period data is perhaps now possible Autocorrelated data requires time-series analysis. This technique is now being extended to series with non-gaussian distributions DRIs can provide the large data-sets that are required for time series analysis, hundreds or thousands of values (8 hr at once per second is 4,800 values)

46 Summary of Talk The barriers to use of DRIs were reduced by: 1. Showing that use of the C-tube correction makes DRIs comparable in accuracy and precision to pump-and-tube methods, despite the presence of interference 2. Documented a standard procedure for use of the C-tube correction method, taking instrument response time into account 3. Provided a spreadsheet to use the C-tube correction method and to automate analysis of the data sets for STEL, excursion or ceiling limits

Questions, Myths and Misconceptions about Using Photoionization Detectors

Questions, Myths and Misconceptions about Using Photoionization Detectors Questions, Myths and Misconceptions about Using Photoionization Detectors Solvent, fuel and other VOC vapours are pervasively common in many workplace environments. Increased awareness of the toxicity

More information

Introduction to IH Analytical Chemistry

Introduction to IH Analytical Chemistry Introduction to IH Analytical Chemistry Sampling and Analysis Manning, Eide, Van Etten (Apr 2013) Foreword Thank you for purchasing the Introduction to IH Analytical Chemistry self-study workbook. Course

More information

Lab Standard/Hazard Communication Training. MTU Dept. of Chemistry November 17, 2006

Lab Standard/Hazard Communication Training. MTU Dept. of Chemistry November 17, 2006 Lab Standard/Hazard Communication Training MTU Dept. of Chemistry November 17, 2006 Lab Standard/HazComm Lab Standard vs. Hazard Communication Who is required to have training: Under OSHA, the term worker

More information

HYDROCARBONS, AROMATIC 1501

HYDROCARBONS, AROMATIC 1501 HYDROCARBONS, AROMATIC 1501 FORMULA: Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1 METHOD: 1501, Issue 3 EVALUATION: Full Issue 1: 15 August 1990 Issue 3: 15 March 2003 OSHA : Table 2 NIOSH: Table 2

More information

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV Summary Honeywell RAE Systems strongly recommends using 100 ppm propane as calibration gas for instruments with 11.7eV

More information

Hazard Communication PPT-SM-HAZCOM V.A.0.0

Hazard Communication PPT-SM-HAZCOM V.A.0.0 Hazard Communication 1 Right to Know HazCom standard ensures the right of workers to know about the chemicals they work with HazCom is Frequently cited by OSHA The process of identifying hazards associated

More information

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes

More information

MEASURING NANOPARTICLE EXPOSURE

MEASURING NANOPARTICLE EXPOSURE MEASURING NANOPARTICLE EXPOSURE APPLICATION NOTE NSAM-001 The Nanoparticle Surface Area Monitor reports the surface area of inhaled particles deposited in the lung Nanoparticle Exposure There is increasing

More information

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers RS DYNAMICS ECOPROBE 5 Portable IR/PID Gas Analyzer PID + IR PID and IR Analyzers General ECOPROBE 5 has two autonomous analyzers in one case. The combination of analyzers provides a set of data designed

More information

Determination of Short-term Exposure with a Direct Reading Photoionization Detector

Determination of Short-term Exposure with a Direct Reading Photoionization Detector Ann. occup. Hyg., Vol. 48, No. 1, pp. 75 84, 2004 2004 British Occupational Hygiene Society Published by Oxford University Press DOI: 10.1093/annhyg/meg079 Determination of Short-term Exposure with a Direct

More information

Raw Material Finished product By product Exposure standards Length of shift Physical environment

Raw Material Finished product By product Exposure standards Length of shift Physical environment Measurement &Sampling Part 1 Introduction to Sampling What to sample? - Hazard Raw Material Finished product By product Exposure standards Length of shift Recognition Physical environment To Determine

More information

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003 ALCOHOLS IV 1403 (1) HOCH 2 CH 2 OCH 3 MW: (1) 76.09 CAS: (1) 109-86-4 RTECS: (1) KL5775000 (2) HOCH 2 CH 2 OCH 2 CH 3 (2) 90.12 (2) 110-80-5 (2) KK8050000 (3) HOCH 2 CH 2 O(CH 2 ) 3 CH 3 (3) 118.17 (3)

More information

Slide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications

Slide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications Slide 1 Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications Bob Henderson, BS, MBA GFG Instrumentation Inc. Ann Arbor, MI Toll free: 800-959-0329 Mobile: 734-355-1291 E-mail:

More information

RADIATION-METER TM-91/TM-92

RADIATION-METER TM-91/TM-92 RADIATION-METER TM-91/TM-92 User s Manual EN 1 / 16 CONTENTS 1. introduction... 3 2. Safety Precaution... 4 3. Specification... 6 4. Identifying parts... 7 5. Operation Procedure... 8 6. Battery Replacement...

More information

Industrial Hygiene Report

Industrial Hygiene Report Industrial Hygiene Report Control of Hydrochloric Acid Vapors in a Lab Setting September, 24 2012 Sentry Air Systems 6999 W. Little York Rd, Suite P1 Houston, TX 77040 BACKGROUND: Hydrochloric acid, an

More information

IV. DIRECT MEASUREMENT LABS. Introduction

IV. DIRECT MEASUREMENT LABS. Introduction IV. DIRECT MEASUREMENT LABS VI-1 I. Purpose Introduction An industrial hygienist frequently needs to evaluate airborne gas and vapor concentrations "on the spot". In other cases, he needs to track down

More information

Analyzing the Incident: Detecting, Monitoring, and Sampling Hazardous Materials

Analyzing the Incident: Detecting, Monitoring, and Sampling Hazardous Materials Analyzing the Incident: Detecting, Monitoring, and Sampling Hazardous Materials Chapter Contents Exposure...161 Routes of Entry...161 Contamination versus Exposure...162 Acute versus Chronic Exposure...163

More information

CHEMISTRY 130 General Chemistry I. Radioisotopes

CHEMISTRY 130 General Chemistry I. Radioisotopes CHEMISTRY 130 General Chemistry I Radioisotopes Positron Emission Tomography or PET scans use the radioisotope 18 F to create an image of the brain. DEPARTMENT OF CHEMISTRY UNIVERSITY OF KANSAS Radioisotopes

More information

ORGANOPHOSPHORUS PESTICIDES 5600

ORGANOPHOSPHORUS PESTICIDES 5600 ORGANOPHOSPHORUS PESTICIDES 5600 Formula: Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1 METHOD: 5600, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : Table 2 NIOSH: Table 2 ACGIH: Table 2 PROPERTIES:

More information

IMPROVING THE SPECIFICITY OF INFRARED BREATH ANALYZERS. * D. G. Hutson SYNOPSIS

IMPROVING THE SPECIFICITY OF INFRARED BREATH ANALYZERS. * D. G. Hutson SYNOPSIS IMPROVING THE SPECIFICITY OF INFRARED BREATH ANALYZERS * D. G. Hutson SYNOPSIS In the advent of infrared forensic breath-alcohol testing instruments, courts are still raising the question of specificity.

More information

Sampling for Gases and Vapors

Sampling for Gases and Vapors Sampling for Gases and Vapors EOH 466B Evaluating the Occupational Environment Spring 2008 Gases and Vapors Gases: don't exist in liquid state at STP e.g.: nitrous oxides, ozone, carbon monoxide Vapors:

More information

An environmental survey of compliance with Occupational Exposure Standards (OES) for anaesthetic gases

An environmental survey of compliance with Occupational Exposure Standards (OES) for anaesthetic gases An environmental survey of compliance with Occupational Exposure Standards (OES) for anaesthetic gases K. A. Henderson 1 and I. P. Matthews 2 1 Environmental Adviser, Health and Safety Unit, and 2 Reader,

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET S E C T I O N 1 - I D E N T I F I C A T I O N O F P R O D U C T A N D C O M P A N Y Pfizer Inc Pfizer Animal Health 2 3 5 E a s t 4 2 n d S t r e e t N e w Y o r k, N Y 1 0 0

More information

PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS

PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS ABSTRACT LEDs are used in many applications, ranging from signalling to ambient lighting to displays. Specifications and tolerances are used

More information

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time?

1. What would be the dose rate of two curies of 60Co with combined energies of 2500 kev given off 100% of the time? 1.11 WORKSHEET #1 1. What would be the dose rate of two curies of 60Co with combined energies of 500 kev given off 100% of the time?. What would be the dose rate of 450 mci of 137Cs (gamma yield is 90%)?

More information

Validation of. Tetrahydrofuran Using. SKC Passive Sampler Cat. No

Validation of. Tetrahydrofuran Using. SKC Passive Sampler Cat. No Validation of Tetrahydrofuran Using SKC Passive Sampler Cat. No. 575-002 Page 1 of 10 Publication 1841 Issue 1407 Research Report Validation of Tetrahydrofuran Using the SKC Cat. No. 575-002 Passive Sampler

More information

MODULE 4.3 Atmospheric analysis of particulates

MODULE 4.3 Atmospheric analysis of particulates MODULE 4.3 Atmospheric analysis of particulates Measurement And Characterisation Of The Particulate Content 1 Total particulate concentration 1 Composition of the particulate 1 Determination of particle

More information

Fume Hood Face Velocity Can it Ensure Safe Containment?

Fume Hood Face Velocity Can it Ensure Safe Containment? Technology Report February, 2004 Fume Hood Face Velocity Can it Ensure Safe Containment? This paper examines the controversy that sometimes arises regarding whether fume hood face velocity is indicative

More information

Basic Hazard Communication

Basic Hazard Communication Basic Hazard Communication IH & Containment Conference Rome, May 14-16, 2013 Janssen Campus Belgium Michel Vangeel Principal Expert Industrial Hygiene & Ergonomics mvangeel@its.jnj.com Why Chemical Hazard

More information

EQUATIONS FOR CALCULATING EXPOSURE MANAGEMENT OBJECTIVES

EQUATIONS FOR CALCULATING EXPOSURE MANAGEMENT OBJECTIVES Technical Report No. 05-02 January 2005 www.oesh.com EQUATIONS FOR CALCULATING EXPOSURE MANAGEMENT OBJECTIVES Paul Hewett Ph.D. CIH 1 ABSTRACT 2 INTRODUCTION 3 VARIABLES 4 BACKGROUND 5 THE COMPONENTS OF

More information

#03 Laboratory Ventilation and Risk Assessment Exercise John Cullen, Monroe Community College, Rochester, NY 14623

#03 Laboratory Ventilation and Risk Assessment Exercise John Cullen, Monroe Community College, Rochester, NY 14623 #0 Laboratory Ventilation and Risk Assessment Exercise John Cullen, Monroe Community College, Rochester, NY 1462 INTRODUCTION This exercise is designed to introduce students to the analysis of health risks

More information

Lesson 5: Solving Linear Systems Problem Solving Assignment solutions

Lesson 5: Solving Linear Systems Problem Solving Assignment solutions Write inequalities to represent the following problem, and then solve to answer the question. 1. The Rent-A-Lemon Car Rental Company charges $60 a day to rent a car and an additional $0.40 per mile. Alex

More information

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY WHITEPAPER ENGLISH PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY PARTICLE MEASUREMENT Particle measurement in cleanrooms. WP1508006-0100-EN, V1R0, 2015-08 PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

More information

Sample Date (Required) IH UIC (Required) The date the sample is collected.

Sample Date (Required) IH UIC (Required) The date the sample is collected. Navy and Marine Corps Public Health Center Industrial Hygiene Direct Reading Sample Survey Form - NMCPHC Form 5100/15.2 Explanations and Definitions (Version 09/2014) Industrial Hygiene Direct Reading

More information

Sample Date (Required) IH UIC (Required) The date the sample is collected.

Sample Date (Required) IH UIC (Required) The date the sample is collected. Navy and Marine Corps Public Health Center Industrial Hygiene Direct Reading Single Stressor Sample Survey Form - NMCPHC Form 5100/15.1 Explanations and Definitions (Version 09/2014) Industrial Hygiene

More information

Uncertainty: A Reading Guide and Self-Paced Tutorial

Uncertainty: A Reading Guide and Self-Paced Tutorial Uncertainty: A Reading Guide and Self-Paced Tutorial First, read the description of uncertainty at the Experimental Uncertainty Review link on the Physics 108 web page, up to and including Rule 6, making

More information

Use of Data Logger Devices in the Collection of Site- Specific Weather Information. Peter de Bruijn, RPF. June Fire Report FR

Use of Data Logger Devices in the Collection of Site- Specific Weather Information. Peter de Bruijn, RPF. June Fire Report FR Wildland Fire Operations Research Group (WFORG) 1176 Switzer Drive Hinton AB T7V 1V3 http://fire.feric.ca Use of Data Logger Devices in the Collection of Site- Specific Weather Information Fire Report

More information

INDUSTRIAL HYGIENE DIRECT READING SINGLE STRESSOR SAMPLE SURVEY FORM

INDUSTRIAL HYGIENE DIRECT READING SINGLE STRESSOR SAMPLE SURVEY FORM INDUSTRIAL HYGIENE DIRECT READING SINGLE STRESSOR SAMPLE SURVEY FORM Sample Date: IH UIC: Activity: UIC: Field Office: Bldg./Hull #: Shop Location: Shop Code/Name: Shift: 1. Day Frequency of 1. Daily 2.

More information

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority: Title: Chemical Hygiene Written Program Effective Date: November 2005 Revision Date: February 8, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten Test Report Glava AS Emission test of Ecophon Venus according to M1 classification October / November 2006 Client: Glava AS Nybråtveien 2 1832 Askim Norge Date: 8 th of November 2006 Testing Laboratory:

More information

CHEMISTRY 170. Radioisotopes

CHEMISTRY 170. Radioisotopes CHEMISTRY 170 Radioisotopes Positron Emission Tomography or PET scans use the radioisotope 18 F to create an image of the brain. DEPARTMENT OF CHEMISTRY UNIVERSITY OF KANSAS Radioisotopes Introduction

More information

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Whole Tablet Measurements Using the Frontier Tablet Autosampler System a p p l i c a t i o n N O T E Whole Tablet Measurements Using the Frontier Tablet Autosampler System FT-NIR Spectroscopy Introduction Recent advances in NIR technology have changed the ways in which both

More information

Mercury Vapour Analysers: Finding the Right Fit for Your Needs

Mercury Vapour Analysers: Finding the Right Fit for Your Needs Mercury Vapour Analysers: Finding the Right Fit for Your Needs The toxic effects of mercury vapour on human health have been well documented throughout the years. mercury detection with few interferences

More information

Laboratory Validation of Ozone Sampling with Spill-Proof Impingers

Laboratory Validation of Ozone Sampling with Spill-Proof Impingers Laboratory Validation of Ozone Sampling with Spill-Proof Impingers Laboratory Validation of Ozone Sampling with Spill-Proof Impingers Research performed by the Southern Research Institutes, Birmingham,

More information

Graphing Motion (Part 1 Distance)

Graphing Motion (Part 1 Distance) Unit Graphing Motion (Part 1 Distance) Directions: Work in your group (2 or 3 people) on the following activity. Choose ONE group member to be the subject (the person who walks to/from motion detector).

More information

I. Pre-Lab Introduction

I. Pre-Lab Introduction I. Pre-Lab Introduction Please complete the following pages before the lab by filling in the requested items. A. Atomic notation: Atoms are composed of a nucleus containing neutrons and protons surrounded

More information

The Theory of HPLC. Quantitative and Qualitative HPLC

The Theory of HPLC. Quantitative and Qualitative HPLC The Theory of HPLC Quantitative and Qualitative HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference

More information

Laboratory Chemical Safety. Pathology Training

Laboratory Chemical Safety. Pathology Training Laboratory Chemical Safety Pathology Training Objectives Explain the OSHA standard for chemical safety as it relates to laboratory workers Explain Chemical labeling requirements Explain the NFPA diamond

More information

12 Moderator And Moderator System

12 Moderator And Moderator System 12 Moderator And Moderator System 12.1 Introduction Nuclear fuel produces heat by fission. In the fission process, fissile atoms split after absorbing slow neutrons. This releases fast neutrons and generates

More information

Evaluation and Measurements of Radioactive Air Emission and Off-Site Doses at SLAC

Evaluation and Measurements of Radioactive Air Emission and Off-Site Doses at SLAC SLAC-PUB-15365 Evaluation and Measurements of Radioactive Air Emission and Off-Site Doses at SLAC I.Chan, J.Liu, H.Tran SLAC National Accelerator Laboratory, M.S. 48, 2575 Sand Hill Road, Menlo Park, CA,

More information

Compliance with occupational limit values by applying workplace measurements

Compliance with occupational limit values by applying workplace measurements Occupational Limit Values for Hazardous Substances - Healthy working conditions in a global economy Conference under the German Presidency of the European Council, Dortmund, Germany, 7-8 May 2007 Compliance

More information

Introduction. 1. Safety and chemical exposure

Introduction. 1. Safety and chemical exposure Mitigating health risks with laboratory fume hoods Dominique Laloux,General Manager, Kunshan Erlab DFSL, China Teddy Pitot, Area Sales Manager, Erlab Southeast Asia, Malaysia Introduction Safety is a very

More information

A Study of the Mass Emission Rates of Small Spills of Chlorinated. Hydrocarbons Based on the Vapor Pressure and Surface Area to

A Study of the Mass Emission Rates of Small Spills of Chlorinated. Hydrocarbons Based on the Vapor Pressure and Surface Area to A Study of the Mass Emission Rates of Small Spills of Chlorinated Hydrocarbons Based on the Vapor Pressure and Surface Area to Volume Ratio of the Spill Chad Joseph Positano Medical College of Ohio 2004

More information

A METHOD FOR EVALUATING HAZARDS OF LOW VOLATILITY TOXIC LIQUIDS

A METHOD FOR EVALUATING HAZARDS OF LOW VOLATILITY TOXIC LIQUIDS A METHOD FOR EVALUANG HAZARDS OF LOW VOLALITY TOXIC LIQUIDS Timothy A. Melton and David W. Johnson Presented At 1998 Plant Safety Symposium Houston, Texas October 26-27, 1998 Presented By Quest Consultants

More information

Fundamentals of Particle Counting

Fundamentals of Particle Counting Fundamentals of Particle Counting 1 Particle Counting: Remains the most significant technique for determining the cleanliness level of a fluid Useful as a tool for qualification and monitoring cleanroom

More information

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS APPLICATION NOTE LIBS-023 Quantitative elemental composition analysis is possible using size-selected aerosol samples collected

More information

Understanding catalytic LEL combustible gas sensor performance

Understanding catalytic LEL combustible gas sensor performance : Understanding catalytic LEL combustible gas sensor performance These four conditions are frequently diagrammed as the "Fire Tetrahedron". If any side of the tetrahedron is missing, incomplete or insubstantial;

More information

AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide. Lab days: Thursday and Friday, February 1-2, 2018

AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide. Lab days: Thursday and Friday, February 1-2, 2018 AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide Lab days: Thursday and Friday, February 1-2, 2018 Lab due: TBD Goal (list in your lab book): The goal of this lab is to

More information

"Employee Right To Know" Environmental, Health, and Safety Department

Employee Right To Know Environmental, Health, and Safety Department EASTERN ILLINOIS UNIVERSITY, Charleston, Illinois MODEL WRITTEN HAZARD COMMUNICATION PROGRAM "Employee Right To Know" Environmental, Health, and Safety Department SELF HELP SOURCES FOR MSDS INFORMATION:

More information

Experience with data handling in large chemical databases NEAL LANGERMAN

Experience with data handling in large chemical databases NEAL LANGERMAN Experience with data handling in large chemical databases NEAL LANGERMAN Advanced Chemical Safety San Diego, California, USA Provide integrated chemical health and safety information with a strong emphasis

More information

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953) Real-Time Detection: 1953 From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953) Sampling Gases and Vapors Gas: A state of matter characterized by very low density and

More information

Proposal of a model for chemical risk preliminary assessment

Proposal of a model for chemical risk preliminary assessment Safety and Security Engineering II 29 Proposal of a model for chemical risk preliminary assessment S. Apolloni 1, M. Fera 1 & R. Macchiaroli 2 1 Dipartimento di Progettazione e Gestione Industriale, Università

More information

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3 Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3 1 CANBERRA Industries, Meriden, CT 06450 2 Los Alamos National Laboratory,

More information

Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1

Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1 Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1 Introduction: The Occupational Safety & Health Administration (OSHA) Hazard Communication

More information

Exponential Decay. Enter the two points in the spreadsheet and make a list. b. Find an exponential regression model.

Exponential Decay. Enter the two points in the spreadsheet and make a list. b. Find an exponential regression model. Exponential Decay Example 5: At the beginning of a study, there are 50 grams of a substance present. After 17 days, there are 38.7 grams remaining. Assume the substance decays exponentially. a. State the

More information

Chapter 3 Engineering Solutions. 3.4 and 3.5 Problem Presentation

Chapter 3 Engineering Solutions. 3.4 and 3.5 Problem Presentation Chapter 3 Engineering Solutions 3.4 and 3.5 Problem Presentation Organize your work as follows (see book): Problem Statement Theory and Assumptions Solution Verification Tools: Pencil and Paper See Fig.

More information

Technical Paper 3 Verifying Particle Counter Calibration: Size Verification

Technical Paper 3 Verifying Particle Counter Calibration: Size Verification Technical Paper 3 Verifying Particle Counter Calibration: Size Verification By D. John Hunt, Pacific Scientific Instruments. Originally printed in Pollution Equipment News Publication, June 1996. Volume

More information

Bright Advance Corporation

Bright Advance Corporation USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS

More information

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect Microscanner D-Series The Only Certified Accurate Surface Instruments in the World A MUST FOR ISO 9001 ISO 9002 ISO 9003 TRACEABILITY PROGRAMS Common Surface Measurement Errors D501 and D501-RS Microscanner

More information

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System A P P L I C A T I O N N O T E Introduction Recent advances in NIR technology have changed the ways in which both the pharmaceutical

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department Physics 8.01 Fall Term 2010 Experiment 03: Work and Energy Purpose of the Experiment: In this experiment you allow a cart to roll down an inclined

More information

METHAMPHETAMINE WIPE SAMPLING TECHNIQUES

METHAMPHETAMINE WIPE SAMPLING TECHNIQUES METHAMPHETAMINE WIPE SAMPLING TECHNIQUES When sampling for methamphetamine and its precursors on surfaces using methanol moistened wipes, there are a number of sampling techniques that have been developed

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

Volatile Organic Compounds (VOC) Probes

Volatile Organic Compounds (VOC) Probes Volatile Organic Compounds (VOC) Probes New Plug and Play accessory probes Compatible with the new 9565 VelociCalc and 7575 Qtrak Also compatible with the 9555 VelociCalc and 7565 Qtrak Firmware must be

More information

VOC TEST REPORT CDPH

VOC TEST REPORT CDPH Baux AB Östermalmsgatan 26A 114 26 Stockholm SWEDEN Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing VOC TEST REPORT CDPH 29 September 2017

More information

Good morning everyone, and welcome again to MSLs World Metrology Day celebrations.

Good morning everyone, and welcome again to MSLs World Metrology Day celebrations. Thank you Gavin.. Good morning everyone, and welcome again to MSLs World Metrology Day celebrations. The aim of this talk is to explain the changes that will be made with the change in the definition of

More information

Ch Radioactivity. Henry Becquerel, using U-238, discovered the radioactive nature of elements in 1896.

Ch Radioactivity. Henry Becquerel, using U-238, discovered the radioactive nature of elements in 1896. Ch. 10 - Radioactivity Henry Becquerel, using U-238, discovered the radioactive nature of elements in 1896. Radioactivity the process in which an unstable atomic nucleus emits charged particles and energy

More information

Formaldehyde Fluorescent Detection Kit

Formaldehyde Fluorescent Detection Kit K-ASSAY KAMIYA BIOMEDICAL COMPANY KAMIYA BIOMEDICAL COMPANY Formaldehyde Fluorescent Detection Kit For detection in human urine and tissue culture media Cat. No. KT-723 For Research Use Only. Not for Use

More information

Section 3.5 Thermal Comfort and Heat Stress

Section 3.5 Thermal Comfort and Heat Stress Section 3.5 Thermal Comfort and Heat Stress Table 3.6 Metabolic rate as a function of physical activity for a 70 kg adult man (abstracted from ASHRAE, 1997). activity metabolic rate (W) metabolic rate

More information

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds Atmospheric Analysis Gases Sampling and analysis of gaseous compounds Introduction - External environment (ambient air) ; global warming, acid rain, introduction of pollutants, etc - Internal environment

More information

Triad-Friendly Approaches to Data Collection Design

Triad-Friendly Approaches to Data Collection Design Triad-Friendly Approaches to Data Collection Design Alternative Triad-Friendly Approaches Collaborative Data Sets Weight-of-evidence approaches Using lower analytical quality data for search, higher analytical

More information

ENVH 555. Industrial Hygiene Methods: Laboratory

ENVH 555. Industrial Hygiene Methods: Laboratory ENVH 555 Industrial Hygiene Methods: Laboratory Spring, 2009 Class Website: http://courses.washington.edu/envh555 Instructors: Christopher Simpson Office: F226C Phone: 543-3222 Email: simpson1@u.washington.edu

More information

The Lab-Field Gap between IH Chemists and IH Non- Chemists - A Chemist's View. C.R. (Gus) Manning

The Lab-Field Gap between IH Chemists and IH Non- Chemists - A Chemist's View. C.R. (Gus) Manning The Lab-Field Gap between IH Chemists and IH Non- Chemists - A Chemist's View C.R. (Gus) Manning Industrial Hygiene (AIHA) the science and art devoted to anticipation, recognition, evaluation, prevention,

More information

Strategies For Selecting Air Sampling Methods AIHA-Florida Section Spring Conference

Strategies For Selecting Air Sampling Methods AIHA-Florida Section Spring Conference Strategies For Selecting Air Sampling Methods 2011 AIHA-Florida Section Spring Conference Course Outline What are we going to sample for Sampling media Active sampling, diffusive samplers, direct read

More information

Technical/Application Article 01 Version 1.2

Technical/Application Article 01 Version 1.2 Technical/Application Article 01 Version 1.2 th 25 January 2017 WRH What is a PID? Introduction PID is the abbreviation for Photo-Ionization Detector. A PID is a hand-held, personal, or fixed wallmounted

More information

Computer Aided Assessment and Design of Occupationally Healthier Process during Research and Development Stage

Computer Aided Assessment and Design of Occupationally Healthier Process during Research and Development Stage A publication of VOL. 26, 2012 CHEMICAL ENGINEERINGTRANSACTIONS Guest Editors:Valerio Cozzani, Eddy De Rademaeker Copyright 2012, AIDIC Servizi S.r.l., ISBN 978-88-95608-17-4; ISSN 1974-9791 The Italian

More information

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace_Rev3 Introducing

More information

STA 584 Supplementary Examples (not to be graded) Fall, 2003

STA 584 Supplementary Examples (not to be graded) Fall, 2003 Page 1 of 8 Central Michigan University Department of Mathematics STA 584 Supplementary Examples (not to be graded) Fall, 003 1. (a) If A and B are independent events, P(A) =.40 and P(B) =.70, find (i)

More information

Lab 01: Harmonic Motion I. Theory: Three experiments. The first we measure the oscillation of a spring, the second of a rubber band (non-linear).

Lab 01: Harmonic Motion I. Theory: Three experiments. The first we measure the oscillation of a spring, the second of a rubber band (non-linear). Dr. W. Pezzaglia Physics 8C Lab, Spring 04 Page Las Positas College Lab # Harmonic Motion 04Jan3 Lab 0: Harmonic Motion I. Theory: Three experiments. The first we measure the oscillation of a spring, the

More information

The Critical Velocity for Smoke Control

The Critical Velocity for Smoke Control The Critical Velocity for Smoke Control Dr Fathi Tarada Managing Director, Mosen Ltd Chief Executive, HBI Haerter Ltd Bill Kennedy Bill Kennedy was a leading thinker in the area of critical velocity Application

More information

HAZARD COMMUNICATION and GHS. Environmental Health and Safety

HAZARD COMMUNICATION and GHS. Environmental Health and Safety HAZARD COMMUNICATION and GHS Environmental Health and Safety RIGHT-TO-KNOW LAW OSHA created the Hazard Communication Standard in 1983. Applies to all places of employment where employees are exposed to

More information

Media blank result for a single-section sampler (e.g., membrane filter). Media blank result for back section of a sampler.

Media blank result for a single-section sampler (e.g., membrane filter). Media blank result for back section of a sampler. IV. GLOSSARY OF ABBREVIATIONS, DEFINITIONS, AND SYMBOLS AAS Acceptable range (biological) Accuracy ACGIH Ashing ASV B B b B f Bias Bioaerosol Biological monitoring Blank Atomic absorption spectrophotometry.

More information

1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer. Description: Natural occuring clay mineral SDS. GHS Safety Data Sheet. PROFILE Products, LLC

1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer. Description: Natural occuring clay mineral SDS. GHS Safety Data Sheet. PROFILE Products, LLC Page 1 of 5 1 PRODUCT AND COMPANY IDENTIFICATION Manufacturer 750 LAKE COOK ROAD SUITE 440 BUFFALO GROVE, IL 60089 Emergency: Contact: Phone: Fax: Email: Web: Emergency Phone: (800) 424-9300 (ChemTrec

More information

Nanomaterials: Why risk assessment is so difficult

Nanomaterials: Why risk assessment is so difficult Nanomaterials: Why risk assessment is so difficult DL-18813-2014 The production of nanomaterials is booming worldwide. At the same time, they are suspected of having serious health effects. Drägerwerk

More information

SECTION D.2 AMMONIA NITROGEN

SECTION D.2 AMMONIA NITROGEN SECTION D.2 AMMONIA NITROGEN CEDR Method Code: NH4F L01 a) Scope and Application i) This method describes the determination of low-level ammonia nitrogen concentrations in filtered samples taken from fresh

More information

LAB 2 - ONE DIMENSIONAL MOTION

LAB 2 - ONE DIMENSIONAL MOTION Name Date Partners L02-1 LAB 2 - ONE DIMENSIONAL MOTION OBJECTIVES Slow and steady wins the race. Aesop s fable: The Hare and the Tortoise To learn how to use a motion detector and gain more familiarity

More information

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW Inductively Coupled Plasma Mass Spectrometry (ICP-MS) What is a Plasma? - The magnetic field created by a RF (radio frequency) coil produces

More information

On the use of Deming and quadratic calibrations in analytical chemistry

On the use of Deming and quadratic calibrations in analytical chemistry On the use of Deming and quadratic calibrations in analytical chemistry Henry Foden Rand Water October 09-2013 PO Box 3526, Vereeniging, 1930, Republic of South Africa e-mail: hfoden@randwater.co.za Phone:

More information

Certificate: / 29 April 2014

Certificate: / 29 April 2014 Test report: 936/21218896/A of 20 September 2013 Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter IV, No. 5.1 Approved application The

More information

Graphical Data Analysis Minneapolis Community and Tech. College v Experimental Measurements. Graphical Analysis and Straight lines

Graphical Data Analysis Minneapolis Community and Tech. College v Experimental Measurements. Graphical Analysis and Straight lines Graphical Data Analysis Minneapolis Community and Tech. College v.8.08 Experimental Measurements All experimentally measured numbers consist of one or more exact numbers that contain no uncertainty and

More information