GT-510/510L series Instruction Manual
|
|
- Toby Bates
- 5 years ago
- Views:
Transcription
1 GT-510/510L series Instruction Manual NO
2 Contents 1 INSTRUMENT FEATURES QUICK GUIDE INSTRUMENT PACKING NAME OF INSTRUMENT PARTS UNPACK AND STORAGE HANDLING, INFORMATION AND CHARGING OF THE BATTERY INSTALLATION OF THE INSTRUMENT INSTRUMENT OPERATION KEYS AND DISPLAY INSTRUCTIONS KEYBOARD SYMBOLS AND FUNCTIONS LCD PARAMETER SETTINGS PREPARING FOR MEASUREMENT INSTRUMENT PLACEMENT, CENTERING AND LEVELING Plumb bob on leveling Use the plummet for centering TELESCOPE EYEPIECE ADJUSTMENT AND TARGET SIGHTING SWITCH ON AND OFF
3 6 BASIC MEASUREMENT DISC / DISK LEFT RIGHT SWITCH SET HORIZONTAL ANGLE TO ZERO ANGLE LOCK THE VERTICAL ANGLE MODE SWITCH INTO THE SWITCHING STATE LIGHTING OPEN CLOSE SWITCH AT RIGHT ANGLES TO BEEP SWITCHING COMPENSATOR OUTPUT ANGLE DATA ANGLE MEASUREMENT HORIZONTAL ANGLE MEASUREMENTS (RIGHT CORNER MODE) HORIZONTAL ANGLE MEASUREMENTS (LEFT CORNER MODE) VERTICAL ANGLE MEASUREMENT DATA RECORDING AND TRANSMISSION FUNCTION RECORD THE ANGLE DATA DATA VIEW AND TRANSMISSION LASER POINT FUNCTION (LASER THEODOLITE) L ASER POINT TO OPEN AND CLOSE L ASER POINTING
4 1 Instrument features Our products GT-512L series Electronic Theodolite and laser Electronic Theodolite, absolute encoder angle measurement, eliminating the vertical plate angle initialization process, easy to operate; Large-diameter objective lens system for easytargeting operation; Nice, reasonable structure and ergonomic design; Fully functional, suitable for a variety of applications theodolite angle measurement; collection of data can be done directly. Through the serial port output; simple button operation, only six function keys can achieve a variety of measurement functions; big screen, clear font; display backlight reticle illumination for dark environments operation; laser point instead of optical vertical quasi use is easier than the optical; convenient laser theodolite emitting laser (only for laser theodolite), as a visible line of sight applications in construction. -1-
5 2 Quick Guide 2.1 Instrument packing Note: During the instrument packing, loosen the stopper body! -2-
6 2.2 Name of instrument parts -3-
7 Note: only in the back of the instrument model decorated with the letter L theodolite is laser theodolite. -4-
8 2.3 Unpack and storage Unpack Put down the instrument box lightly, so that the lid upward to open the latch of the box, open the lid and remove the instrument. Storage Telescope vertically down (or up), so that the alidade base of packing marks are aligned, marked the instrument packing up supine into the box and gently tighten the vertical automatic knob cover box cover and lock the case. 2.4 Handling, information and charging of the battery Battery handling Remove the battery box, battery box at the top of the button is pressed outwards pull out at the top of the battery box. When install the battery box the bottom of the battery compartment first projection is inserted into the -5-
9 groove on the instrument, press the top button of the battery compartment, so that it snaps into the instrument fixed homing. Battery Information Continuous work for 8 ~ 10 hours in full battery, Symbol in the lower left corner " " display battery consumption, the battery consumption is as follows: and : Fully charged and operable. : this information, means there is a small amount of power, should be ready to replace the battery or charging before use. lack of power, it will shut down about sustainable few minutes, replace the battery and charging right now. Charging Native 2100mAH NiMH high-energy rechargeable battery, please use the dedicated charger. For charging, connect 220V power supply first, the red light flash, the charger plug into thecharging connector socket, push the battery into the charging deck, red light means charging started, charging six hours or -6-
10 charging lights turn green means the end of charge, pull out the battery. Warning: If the battery is placed improperly (such as positive and negative terminal), may cause an explosion, please follow the instructions for dealing with use batteries. Note: when charging : A one-time batteries; Do not charge the battery before it have not been used or not spent much time on the repeated charge after fully charged, it will shorten the battery's life. Charging in the temperature range of 0 ~ +45, and beyond this range may cause charging abnormality. Do not use any charger or battery that had been damaged. Storage Precautions: The rechargeable batteries are rechargeable about times, fully discharge the battery will shorten its life For better access to the longest battery life, Please ensure that charged once a month. -7-
11 Do not store the battery in high-temperature, high heat or humid places, not to short-circuit the battery, otherwise it will damage the battery. Properly dispose of the battery according to local rules, better recovery, do not throw the batteries in a fire. 2.5 Installation of the instrument Disassembly : If necessary, the instrument can be removedfrom the triangular base, first loosen the base locked twist fixing screws with a screwdriver, andthen lock twist of about 180 counter-clockwiserotation of the base to the instrument base separation. Install Align at instrument directional bulge mark and substrate directional groove, Three fixed foot on instrument corresponding to in hole in substrate, Install instrument on three substrate. lock twist of about 180 clockwise rotation of the base to the instrument lock -8-
12 with substrate, and then tighten the base locked twist fixing screws with a screwdriver. -9-
13 3 Instrument operation keys and display instructions 3.1 Keyboard symbols and functions Display panel No. Name 1 L/R 2 V/% 3 HOLD 4 0 SET 5 SHIFT 6 First function Switch mode of The horizontal angle left and right corner Switch mode of the vertical angle, the inclination Horizontal angle lock Set horizontal angle to zero Second function Output angle Compensator correct switcher Display backlight switcher Horizontal angle right angle buzzer switcher Key function switch Power switcher, and recording data, confirm
14 3.2 LCD VA HAR TITL HOLD The LCD is divided into four lines: The first line----instrument Number. Initialization has been completed in the factory of the instrument, can not be changed. The second line----vertical angle. XXX XX' XX" said the angle of the " degree every minute units; Display for the GON unit angle XXX.XXXX g; show for XX.XXXX% slope. The third line----horizontal angle. The lower right corner of the word "R" for the right corner of the mode, increased clockwise rotation instrument angle; upper right corner of the word "left" means Left angle mode, counterclockwise rotation Instruments will cause angle
15 increase. The fourth line--- Direction, Point, Electricity flag; Other Switch, Compensation, lock logo will display with function on the corresponding
16 4 Parameter settings The instrument can set a number of systemparameters and they are automatically saved when the set is completed. In the off state, press the L/R + 0 SET key, then press the power button boot, you can enter the system parameter setting mode On the screen of display 10 digit is either "0",or "1", each figure or two figures represent the meaning below. Flashing digital can change. L/R keys move left; V/% key is moved to the right; 0 SET key to switch parameters between 0 and 1. After Setting the parameters, you can click the key to shutdown, when reboot the parameters work
17 Parameters described in the following table:
18 5 Preparing for measurement 5.1 Instrument placement, centering and leveling Instrument mounted on a tripod, precise leveling and alignment to ensure the precision of the measurement results Plumb bob on leveling 1.) Set up the tripod Setup the tripod first: extend the extension legs to suitable lengths and tighten the screws on the mid sections. Make sure the legs are spaced at equal intervals and the head is approximately level. Set the tripod so that the head is positioned over the surveying point. Make sure the tripod -11-shoes are firmly fixed in the ground. 2.) Mount the instrument on the tripod head Mount the instrument on the tripod head. Supporting it
19 with one hand, tighten the centering screw on the bottom of the unit to make sure it is secured to the tripod. 3.) Centering and Leveling-Up 1. Position tripod legs so that the plummet is aimed to the ground mark point. Turn the focusing ring of the optical plummet to focus. 2. Turn three foot screws of the tribrach till the center of reticle exactly coincides with the surveying point in any position. 3. Move the tripod legs to centre the circular level. The instrument is now roughly leveled-up. 4.) Center the bubble in the circular level. 1. Screw A Screw B Plate level Bubble Screw C Loosen the horizontal motion clamp, and turn the instrument till the plate level is perpendicular to a line shaped with screws A and B. Adjust the screws A and B to make the bubble in the center of the level
20 2. Screw A Screw B Turn the instrument approximately 90 Adjust screw C, till the bubble in the center of the level. Screw C Repeat above steps until the bubble remains in the center of the plate level while the instrument is rotated to any position. 5.) Center the surveying point again Loosen the centering screw slightly. Looking through the optical plummet eyepiece, slide the instrument over the tripod head until the surveying point is exactly centered in the reticle. Re-tighten the centering screw securely. 6.) Check again to make sure the bubble in the plate level is centered. If not, repeat procedure
21 5.1.2 Use the plummet for centering 1.) Erecting a tripod Setup the tripod first: extend the extension legs to suitable lengths and tighten the screws on the mid sections. Make sure the legs are spaced at equal intervals and the head is approximately level. Set the tripod so that the head is positioned over the surveying point. Make sure the tripod -11-shoes are firmly fixed in the ground. 2.) Mounting and centering Mount the instrument on the tripod head. Tighten the central connecting screw. Turn on the instrument, Press to open Direction light (Only for laser theodolite), Press again to open laser Point, we can see the red laser to the ground out from the base down. Through the laser we can adjust the position of the tripod point observation. So that the next point roughly aims at the station, make all three legs are fixed on the ground. Adjust the instrument three foot spiral to the point precisely to the measurement site. 3.) Do centering and leveling work again refers to
22 chapter step 3 to step Telescope eyepiece adjustment and target sighting Eyepiece adjustment 1. Remove the telescope mirror cover. 2. Pointing to the sky through the telescope, adjusting the eyepiece knob, the most clear reticle crosshairs. Object Sighting 1. Sight to the target with the crude sight. 2. Adjust the telescope focusing knob until the object can been seeing clearly. 3. Tighten the horizontal and vertical brake knob, fine-tune the two micro knob to accurately sight the center of the crosshair to target, move eye up and down for slightly observe, if the relative shift between the two images of the target with the crosshairs, then fine-tune the telescope focusing knob until the two images clear and relatively stationary ended. Clockwise rotation of the focusing knob to closer to the target. Rotate counterclockwise for contrary
23 If step (3) is not adjusted well, the parallax will distort the relationship of the target with the reticle center, then leading to the observation error. Micro knob according to precise target for a final time, should keep the knob clockwise. If the rotation is too far, we d better return and re-sighting knob rotates clockwise. Even if the eventuality vertical angle, we still recommend to sight the target as far as possible with the position of the center of the crosshairs. 5.3 Switch On and Off Switch On Operation: Click button to boot, after boot it will display the surveying interface. Switch Off Operation: Press for 3 seconds, See on the VA HAR 0. F F TILT screen as shown below with the word "0.FF", you can release the button, the instrument is turned off
24 6 Basic measurement 6.1 Disc / disk left right switch 1. Instruments after each boot initialization, the display on the horizontal angle is always displayed as a horizontal angle right XXX XX'XX", means the angle measurement VA HAR TILT mode is right corner", alidade clockwise Click L/R keys rotation angle increases. 2. Click L/R keys, buzzer after the horizontal VA HA L TILT angle transform "horizontal angle XXX XX'XX" said current angle measurement mode "left corner" mode, means counterclockwise rotation
25 cause angle increases. 3. Press L/R key to return to the right corner measurement mode Set Horizontal angle to zero VA HAR TILT Click the 0 SET key, buzzer after the horizontal angle flashes "000 00'00" four flashing process again 0 SET key, then the horizontal angle set to '00 ", otherwise, Click 0 SET keys or to return to the original value of the angle. 0 SET key is valid only on the horizontal angle. VA HAR TILT
26 6.3 Angle lock 1. Click HOLD key, the word "HOLD" will appear in the lower right corner of the screen, however the instrument level rotate, the horizontal angle remains unchanged. 2. Click HOLD key VA HAR TILT Click HOLD keys again, the locking angle will be the current set of horizontal angle, you can continue to measure. VA HAR TILT HOLD
27 6.4 The vertical angle mode switch 1. The instrument boot initialization, the vertical angle of the display mode is the default display for the angle XXX XX'XX "style. 2. Click V/% key, vertical angle will switch to the gradient display mode display "-X.XXXX%" styles. 3. Press V/% key again will switch the angle mode. VA HAR TILT Click V/% keys VA HAR % TILT
28 6.5 Into the switching state 1. Instrument function keys, in addition to SHIFT key, other keys are dual function keys. Printed on the key for the first function and printing on the key panel for a second function. 2. Click SHIFT key, in the bottom of the screen displays the function keys to enter the second functional state. 3. Click SHIFT key again, the function keys back to the first VA HAR Click SHIFT keys VA HAR SHIFT functional status
29 6.6 Lighting Open Close 1. Click SHIFT key, the function keys to enter the second functional state. 2. Click HOLD key, then open the screen backlight and reticle illumination. 3. Click HOLD key, then turn off the screen backlight and reticle illumination. 4. Click SHIFT key, the function keys back to the first functional status. 6.7 Switch at right angles to beep 1. Click SHIFT key, the function keys to enter the second functional state. 2. Click the 0 SET key, then open the right angle buzzer, there will beep when the instrument horizontal angle Go around degrees, allows you to easily find the desired location. 3. And then click the 0 SET key, then turn off the horizontal angle right angle buzzer. 4. Click SHIFT key again, the function keys back to the first functional status
30 6.8 Switching compensator This series theodolite with compensator can switch through switcher. VA HAR Click SHIFT key, the function keys to enter the second functional state. 2. Click V/% key, then open the compensation correction. At this point, if there is no leveling instrument, the vertical Click SHIFT keys VA HAR SHIFT angle is the angle mode or gradient mode, will not display properly unless Click V/% keys the instrument is leveled. 3. Click V/% key to close the compensator, even if the instrument is not VA HAR leveling, it will show E FF SHIFT TILT
31 vertical angle normally. Compensator correction switch is valid only on the vertical angle. 6.9 Output angle data The instrument is equipped with a serial communications, data can be transferred to the PC via the serial port. 1. Click SHIFT key, the function keys to enter the second functional state. 2. Connected to the instrument via the serial port to USB port cable with PC. 3. Open a can receive serial data software. 4. Set with the same instrument baud rate, 8 data bits, 1 stop bit, no parity. 5. Each time you press L/R key instrument angle data transmission to the PC. 6. Outgoing data format: VXXX.XXXX + enter + newline VXXX.XXXX + enter + line feed Outgoing data such as "V \ r \ nh \ r \ n", Then it indicates that the current
32 The vertical angle of: Horizontal angle:
33 7 Angle measurement 7.1 Horizontal angle measurements (right corner mode) 1. The instrument is installed on the site and boot after in leveling. 2. Aim at the target point A of the first. 3. Click the 0 SET key instrument horizontal angle is set to 0 degrees. 4. Aim at the second target point B. 5. The reading apparatus of the horizontal angle (a). VA HAR Click 0 SET keys VA HAR TILT Aim at the second target point VA HAR TILT
34 The first target A: zero The second goal B: 39 23'25 " Horizontal angle (a) = 39 23'25 " 7.2 Horizontal angle measurements (left corner mode) 1. The instrument is installed on the site and boot after in leveling. 2. Click on the L/R key to switch to the horizontal angle of the left corner. 3. Aimed at a target point B. 4. Click the 0 SET key instrument horizontal angle is set to 0 degrees. 5. Aim at the target point A. 6. The reading apparatus of the horizontal angle (a)
35 7.3 Vertical angle measurement 1. The instrument is installed on the site and boot after in leveling. 2. The targeting point A. 3. Vertical angle readout instrument. VA HAR TILT The vertical angle = 90 15'15 " Check the slope, click V/% key
36 8 Data recording and transmission function 8.1 Record the angle data 1. State angle measurement, click SHIFT key. 2. Each measurement is completed, you can click key recording angle data, including horizontal and vertical angles, can record up to 10 data. 8.2 Data View and transmission View Holding L/R key and then press the key after turning instrument on, the interface displays the current record number of angle data, the following figure shows there are 7 data. n
37 Empty data View the data interface, click V/% key to empty the storage of data, then back to the measurement interface. Data transmission Connect instrument to PC via the serial line, open a serial port software to receive data in the PC, set up with the same instrument's baud rate, 8 data bits, 1 stop bit, and by click the L/R keys we can transfer data to a PC, then back to the measurement interface
38 9 Laser point function (laser theodolite) The laser theodolite had added the laser system to telescope system, laser spot coincides with the telescope crosshairs visible in the telescope, convenient application in a variety of engineering construction. 9.1 Laser point to open and close Boot, first press the key, the screen last row shows the pointing, for now the pointing light is open. A second press key to open the next point, the third press key to open pointing light and next-to-point light at the same time, fourth press key will lead both of them to close, and so on. 9.2 Laser pointing Rotate the telescope focusing hand wheel to see the target, when the pointing function is on, the center of the crosshairs is the center of the laser spot, the laser spot is smallest and brightest. When the light is dim, first aim
39 the target, after lit laser, or we can t see the goal.! Pay attention to safety. Note: The laser can injury human eyes! Never watch a laser light source with eyes!
40 Giant Precision Instrument Co., Ltd. No.16, Ln. 134, Liancheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) Tel: Fax:
Fig. 1. instrument is in the case
1. Applications The NETH503 series Electronic Theodolite has an optical incremental grading system which features digital angle measurements. It can achieve measurement, calculating, display and memory
More informationAutomatic Level NP-732
INSTRUCTIONS FOR USE Automatic Level NP-732 Contents Before use 2 1.Nomenclature. 3 2.Operation....4 2-1 Preparing before surveying...4 2-2 Surveying method..........5 2-2-1 Measuring altitude difference...5
More informationFOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software
GeoInstruments Application Note June 25th, 2015 FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software Summary: This support note outlines the procedure which should be followed to calibrate
More informationWelcome to purchase and use our products and thank you for your confidence in our company s products!
PREFACE Dear users: Welcome to purchase and use our products and thank you for your confidence in our company s products! It has been our target to innovate the international-level advanced surveying instrument
More informationDigital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee
Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee Lecture - 17 Total Station Introduction Welcome students, this
More informationDWT-10 Instruction Manual
DWT-10 Instruction Manual For Customer Service Call (781) 848-7702 or Fax (781) 848-8022 Congratulations on your choice of this David White Electronic Digital Transit. We suggest that you read this instruction
More informationR-300 SERIES R-315(N)/R-325(N)/R-335(N) R-322(N)/R-323(N)/R-326. Electronic Total Station. Instruction Manual
PENTAX R-300 (p01-19) 10/30/02 11:20 AM Page c R Instruction Manual Electronic Total Station R-300 SERIES R-315(N)/R-325(N)/R-335(N) R-322(N)/R-323(N)/R-326 PENTAX R-300 (p01-19) 10/30/02 11:20 AM Page
More informationtotal station Instruction manual Basic Procedures
total station R-200series Instruction manual Basic Procedures for R-200 Series R-202NE R-205NE (Power) TI Asahi Co., Ltd. International Sales Department 4-3-4 Ueno Iwatsuki-Ku, Saitama-Shi Saitama, 339-0073
More informationSURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL
SURVEYING INSTRUMENTS DT7C DT20C Electronic Digital Theodolite OPERATOR'S MANUAL This is the mark of the Japan Surveying Instruments Manufacturers Association. SURVEYING INSTRUMENTS DT7C DT20C Electronic
More informationSTONEX ELECTRONIC THEODOLITE STT SERIES. Instruction Manual
STONEX ELECTRONIC THEODOLITE STT SERIES Instruction Manual PREFACE Dear users: Welcome to purchase and use our products and thank you for your confidence in our company s products! It has been our target
More informationCleveland State University
CVE 212 - Surveying Lab #1 MEASURING ANGLES & DISTANCES WITH A TOTAL STATION EQUIPMENT EDMI and Tripod Single prism mounted on a prism pole Field book Pencil 2 Walkie Talkies INTRODUCTION Recent developments
More informationDual Red or Green Electronic Dot Sight Instruction Manual
Dual Red or Green Electronic Dot Sight Instruction Manual 2007 VisionPlus INTRODUCTION: Congratulations on your purchase of a VisionPlus Dual Red/Green Electronic Dot Sight. This is a quality product engineered
More informationINTRODUCTION TO ENGINEERING SURVEYING (CE 1305)
INTRODUCTION TO ENGINEERING SURVEYING (CE 1305) Linear Measurements Sr Dr. Tan Liat Choon Email: tanliatchoon@gmail.com Mobile: 016-4975551 1 EDM, TOTAL STATION, PRISM AND POLE 2 ELECTROMAGNETIC DISTANCE
More informationASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)
OBJECTIVE LENS ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2) This model shipped from January 2001 through July 2002. It fits all 400, 600, 600E, 800, 900 and 1200 models (except the original
More information取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02
取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02 SURVEYING INSTRUMENTS INSTRUCTION MANUAL AUTOMATIC LEVEL AT-B2/B3/B4 Thank you for selecting the AT-B2/B3/B4. Please read this
More informationAutomatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR
Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR CST/Berger 2001 SAL 20/24/28/32 PAGE 1 REV. C 071803 Automatic Level Maintenance Manual User Calibration and Testing... 3 Circular
More informationSURVEYING INSTRUMENTS LDT520 LDT520S. Laser Digital Theodolite. Class 3R Laser Product OPERATOR'S MANUAL
SURVEYING INSTRUMENTS LDT520 LDT520S Laser Digital Theodolite Class 3R Laser Product OPERATOR'S MANUAL Li-ion S Li-ion :This is the mark of the Japan Surveying Instruments Manufacturers Association. SURVEYING
More informationC A S S I N I TRACKER
C A S S I N I TRACKER ASTRONOMICAL REFLECTOR T ELESCOPE SERIES #C-80080TR #C-1100102TR #C-1000120TR #C-1000120TREF #C-900135TR COSMO BRANDS INC. WWW.COSMOSOPTICS.COM 2 CASSINI REFLECTING TELESCOPE OPERATING
More informationCASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION
HQR-800 CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION CONGRATULATIONS ON YOUR PURCHASE OF THE CASSINI CQR-800 TELESCOPE. THIS TELESCOPE HAS BEEN PRODUCED TO PRECISE SPECIFICATIONS. PRIOR TO USING
More informationASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE
Polar Alignment Telescope ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE This polar axis telescope will help you align your mount with the Celestial Poles. When your mount is properly aligned, your telescope's
More informationQuick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C
Quick Start Guide The ieq45 GoTo German Equatorial Mount # 8000C PACKAGE CONTENTS Telescope Mount (with built-in GPS) 3.5 Vixen type dovetail saddle (installed on the mount) 8 Losmandy-D type dovetail
More informationR-1502N R-1503N R-1505N INSTRUCTION MANUAL
TOTAL STATION R-1500SERIES R-1502N R-1503N R-1505N INSTRUCTION MANUAL Basic Procedures Content Exemption clause... 3 PRECAUTIONS REGARDING SAFETY... 4 Usage precautions... 7 1. BASIC OPERATION... 10
More informationOwner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:
Owner's Manual for AUTOMATIC LEVEL NBL Series FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free: 1-888-247-1960 1 1. CONTENTS 2. Nomenclature page 3 3. Care and Maintenance page 4 4. Using your Instrument
More informationmodel SKT05 SKT05L Toll Free: (855) IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar
Operating / Safety Instructions Consignes de fonctionnement / sécurité Instrucciones de funcionamiento y seguridad IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar
More informationW-800 TOTAL STATION BASIC INSTRUCTION SERIES MANUAL W-821NX W-822NX W-823NX W-825NX W-835NX
TOTAL STATION W-800 SERIES BASIC INSTRUCTION MANUAL W-821NX W-822NX W-823NX W-825NX W-835NX TI Asahi Co., Ltd. International Sales Department 4-3-4 Ueno Iwatsuki-Ku, Saitama-Shi Saitama, 339-0073 Japan
More informationLEAPERS, INC. RED/GREEN DOTS
LEAPERS, INC. 1 RED/GREEN DOTS range estimating scopes UTG reticle intensified scopes TOTAL SOLUTION TO YOUR NEEDS -COMMITMENT TO BEST QUALITY, BEST VALUE AND BEST SERVICEwww.LEAPERS.com 32700 Capitol
More informationRECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler
RECON How to Setup the Telescope to Observe This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler 2017 recon.dozuki.com Page 1 of 30 INTRODUCTION This guide
More informationW-800. a truly integrated system COMPACT FLASH
W-800 a truly integrated system SD COMPACT FLASH W-800 simple operation modular software Ergonomic grip Long Range Extended EDM Performance Auto Focus Large easy to use Color graphical touch display, alphanumeric
More informationInstruction Manual. Model #: (Reflector) Lit #: / 06-07
Instruction Manual Model #: 49114500 (Reflector) Model #: 49060700 () Model #: 49070800 () Lit #: 93-0468 / 06-07 PARTS DIAGRAM C E D B A F G H I J NOTE: Actual product may have improvements that are not
More informationDT220 DT520 DT520S DT520A DT520AS DT620 DT620S
SURVEYING INSTRUMENTS DT220 DT520 DT520S DT520A DT520AS DT620 DT620S Electronic Digital Theodolite OPERATOR'S MANUAL This is the mark of the Japan Surveying Instruments Manufacturers Association. SURVEYING
More informationCircular Motion and Centripetal Force
[For International Campus Lab ONLY] Objective Measure the centripetal force with the radius, mass, and speed of a particle in uniform circular motion. Theory ----------------------------- Reference --------------------------
More informationx Builders Level Service Manual
40-690 22x Builders Level Service Manual Item Description Pages.0 Overall Instrument Assembly 2. Main Assembly 2.2 Telescope Assembly 3.3 Base Assembly 4.4 Frame Assembly 5 2.0 Calibration 6-8 2. Vial
More informationGY 301: Geomorphology Lab 5: Total Station Mapping Project
Introduction This is the capstone lab project for GY 301. With the assistance of your team member (4 people per team), you will use the Total Station to survey a topographic map of the campus area (see
More informationAppendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts
Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts Disassembling (classroom) 1. The mount must be locked with the telescope situated horizontally. Note the telescope
More informationproduct manual H-3220A Benkelman Beam
05.12 product manual H-3220A Benkelman Beam General The H-3220A Benkelman Beam Apparatus is a convenient and accurate device used for measuring the deflection of flexible pavements under moving wheel
More informationFree fall with an interface system
Related topics Motion along a straight line subject to constant acceleration, laws governing falling bodies, acceleration due to gravity. Principle and task The fall times t are measured for different
More informationULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE
USER MANUAL ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE ABOUT SIGHTMARK Sightmark offers a wide range of products that include red-dot sights, reflex sights, riflescopes, laser sights, night vision,
More informationUSER MANUAL REFLEX SIGHT. Ultra Shot Plus
USER MANUAL REFLEX SIGHT Ultra Shot Plus ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes, laser sights, night vision and
More information~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)
~.LIETZ DOUBLE CENTER THEODOLITE TM-20C INSTRUCTION MANUAL f~, ~. LI ETZ THE LIETZ COMPANY 1645 E. Del Arno Blvd. Carson, Ca. 90746. (213)537-0410 n INSTRUMENT NOMENCLATURE cr, il (~ iíl i) Ii: in CD CD
More informationNcSTAR SHOOTER II SERIES SCOPE
NcSTAR SHOOTER II SERIES SCOPE Congratulations on the purchase of your New NcSTAR Shooter II Series Scope! The Shooter II Series of scopes gives you many great options, so you can choose the scope that
More informationAssembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922
BAS 16 Telescope Manual Rev 1 Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922 TABLE OF CONTENTS SECTION
More informationOwner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL
Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL 1 1. CONTENTS 2. Nomenclature page 3 3. Care and Maintenance page 4 4. Using your Instrument 4.1 Setting up your Instrument page 5 4.2 Stadia
More informationLT8-300LTU Owner s Guide
LT8-300LTU Owner s Guide LT8-300LTU LT8-300LTULP FOR CUSTOMER SERVICE, PARTS AND REPAIR CALL (765) 581-4097 www.davidwhite.us.com IMPORTANT: IMPORTANT : IMPORTANTE: Read Before Using Lire avant usage Leer
More informationCarlson CR Robotic/Reflectorless Total Station
0 West Second Street Suite 00 Maysville, KY 4056 www.carlsonsw.com Phone: 606-564-508 Fax: 606-564-64 Type starts around here Carlson CR Robotic/Reflectorless Total Station Calibration Overview Congratulations
More informationAssembly and Operation Manual. April 2016
Assembly and Operation Manual April 2016 Table of Contents What is in the OurWeather Box? 3 Step by Step Assembly 13 Building the Weather Sensors 18 Testing the OurWeather Weather Station 28 Power Up OurWeather
More information30 mm Diameter Main Tube 1-4x24 Models
CrossFire MANUAL 30 mm Diameter Main Tube 1-4x24 Models The Crossfire Riflescopes Specifically designed for discriminating hunters and shooters, the Crossfire series of riflescopes offer the highest levels
More informationDirections for use
Directions for use 40070 40080 60050 70060 70076 80060 90060 900114 Fig. 1 Fig. 1A Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 english ENGLISH DIRECTIONS FOR USE 1 Tripod Leg 2 Tripod Leg Adjusting Screw
More informationINSTRUCTION MANUAL. EQ8 Mount V2. Copyright Sky-Watcher
INSTRUCTION MANUAL EQ8 Mount Copyright Sky-Watcher 121213V2 PART I : SETTING UP THE EQ8 MOUNT PART II : POLAR ALIGNMENT PART III : ELECTRONIC CONTROL INTERFACE PART IV : OTHER FEATURES OF THE EQ8 MOUNT
More informationSpotting Scope Instruction Manual
Spotting Scope Instruction Manual Here are the Main Parts of Your orbitor OR7030 B A C A. Telescope Tube F E D B. Dew Shield I C. Eyepiece G D. Diagonal Mirror E. Focuser F. Mount Lock Knob H G. Aiming
More informationTelescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.
Telescope a Simple assembly instructions- Please keep for future reference IMPORTANT 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit. 2. Check
More informationPLI Support Guide: Robotic Total Station Field Calibration
PLI Support Guide: Robotic Total Station Field Calibration Summary: This manual will instruct you on how to properly calibrate your Trimble Robotic Total Station using Trimble Access. Your instrument must
More informationObserving Procedure for C11 GPS
Observing Procedure for C11 GPS By T. W. Fuller Preparation Customize observing list You can install a list of up to 25 custom objects in the telescope database ahead of time, so that you will have them
More informationCIV : THEODOLITE ADJUSTMENT
Unit CIV2202: Surveying 10.1 CIV2202.10: THEODOLITE ADJUSTMENT Table of Contents PREVIEW...2 Introduction...2 Objectives...2 Readings...2 REGULAR CHECKS...2 Tripod...2 Footscrews...2 Tribrach head...3
More informationC A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.
C A S S I N I MODEL : C-900135EQ3 900mm X 135mm COSMO BRANDS INC. WWW.COSMOSOPTICS.COM 2 C A S S I N I C-900135EQ3 TELESCOPE OPERATING INSTRUCTIONS INTRODUCTION CONGRATULATIONS ON YOUR PURCHASE OF THE
More informationCONTENT FORWORDS... 1 FEATURES... 5 PRECAUTIONS BRIEF INTRODUCTION... 7
FORWORDS Congratulations on purchasing Total Station CTS-662 series. This manual will give a detailed and complete instruction about this total station. Please read it carefully before use. 1 CONTENT FORWORDS...
More informationThank you for purchasing this product CONTENT Sky Memo S Features For your Safety Polar Scope WARNING:
INSTRUCTION MANUAL Thank you for purchasing this product Sky Memo S is user-friendly and provides various combinations to satisfy all your needs for astrophotography and time-lapse photography. It is a
More informationToTal STaTion r-400 BaSic ProcedureS TI Asahi Co., Ltd.
Total Station R-400series Instruction manual Basic Procedures for R-400 Series R-422N R-423N R-425N R-435N R-415N TI Asahi Co., Ltd. International Sales Department 4-3-4 Ueno Iwatsuki-Ku, Saitama-Shi Saitama,
More informationHS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)
HS515G-M PARALOW Circle Dot Sight User's Manual Multi Reticle Holosun Technologies Inc. Phone: (909) 594-2888 Fax: (909) 598-4888 E-mail: info@holosun.com COLOR www.holosun.com PARALOW HS515G-M PARALOW
More informationWATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7
WATTS MICROPTIC ALIDADE 20-7 OPERATING INSTRUCTIONS WATTS Operating Instructions for the WATTS MICROPTIC ALIDADE SA100 SA101 RANK PRECISION INDUSTRIES METROLOGY DIVISION Survey Equipment Sales Langston
More informationDual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob
The Vortex Viper PST tm Riflescope Specifically designed for the tactical, law enforcement and committed precision shooting communities, the Viper PST TM series of riflescopes offer the highest levels
More informationCASSINI CQR-120 OPERATING INSTRUCTIONS
CASSINI CQR-120 OPERATING INSTRUCTIONS INTRODUCTION CONGRATULATIONS ON YOUR PURCHASE OF THE CASSINI CQR-120 TELESCOPE. THIS TELESCOPE HAS BEEN PRODUCED TO PRECISE SPECIFICATIONS. PRIOR TO USING YOUR NEW
More information1 YEAR LIMITED WARRANTY TELESCOPES
1 YEAR LIMITED WARRANTY TELESCOPES BARSKA Optics, as manufacturer, warrants this new precision optical product to be free of original defects in materials and/or workmanship for the length of time specified
More informationRed and Green Dot Sight FF26002 USER MANUAL
Red and Green Dot Sight FF26002 USER MANUAL The Firefield brand has recently launched with products designed to maximize every intense moment. Originally designed for consumers who need products to hold
More information22X Builder s Level Model No Instruction Manual
2594H 7/29/09 10:12 AM Page 1 22X Builder s Level Model No. 40-6900 Instruction Manual Congratulations on your choice of this 22X Builder s Level. We suggest you read this instruction manual thoroughly
More informationTHE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY S OF THE 16 MEADE. A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope
THE S OF THE 16 MEADE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope First draft: Scott Engle, Fall 2010; Update: Steve Boughn, Fall 2012
More information10 - Celestron Telescope II: Operation
10 - Celestron Telescope II: Operation Purpose: Gain more experience setting up a 6 Celestron telescope, familiarize yourself with the software interface, and acquire an image with the CCD camera. Due:
More informationTraining Guide. Coastal Environmental Systems, Inc.
WEATHERPAK TRx2 Coastal Environmental Systems, Inc. 820 First Avenue South Seattle, WA 98134 206.682.6048 800.488.8291 206.682.5658 Fax www.coastalenvironmental.com 11-16-2012 WEATHERPAK is the #1 Choice
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More information22X Builder s Transit Level Model No Instruction Manual
2595H 7/29/09 10:15 AM Page 1 22X Builder s Transit Level Model No. 40-6910 Instruction Manual Congratulations on your choice of this 22X Builder s Transit Level. We suggest you read this instruction manual
More informationIn Association With. Introduces. TPT Contractor
In Association With Introduces TPT Contractor Software for Contractors with TENSIONMETERS Table of Contents Capabilities 4 Setup and Use 7 The Dashboard 12 Tower Setup Form 18 Field Calibration Verification
More informationThe Vortex Razor HD Gen II-E 1 6x24 Riflescope
The Vortex Razor HD Gen II-E 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We carefully built the Razor HD Gen II-E riflescope
More informationKalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual
Kalinka Optics Warehouse User Manual www.kalinkaoptics.com Kobra AK Side Mount Red Dot Sight Manual CONTENTS 1. Introduction... 4 2. Purpose... 4 3. Specifications... 4 4. Components and Equipment Provided...
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationTHE LOSMANDY G-11 MOUNT
Checking the parts THE LOSMANDY G-11 MOUNT Depending on which accessories you ordered, your G-11 mount was shipped in four or more boxes. The contents of each box are as follows: Equatorial Mount Adjustable
More informationMODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.
KL4912 Desktop weather station Instruction Manual Introduction This weather station comes with backlight, indoor and outdoor temperature & humidity display, and alarm clock with calendar. Fig. 1 Front
More informationDHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual
DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131
More informationObservatory 8 inch Telescopes: Tips, Tools & Quick Fixes
Observatory 8 inch Telescopes: Tips, Tools & Quick Fixes Rhiannon Griffin August 7, 2014 1 Tools Needed Allen wrenches for set screws, 2 sizes For collimating: Phillips head screwdriver & slotted screwdriver
More information1.25 Laser Collimator with 2 Adapter Instruction Manual SKU#
1.25 Laser Collimator with 2 Adapter Instruction Manual SKU# 651002 Saxon 1.25 Laser Collimator with 2 Adapter Features Quickly and conveniently collimate your telescope with the saxon Laser Collimator!
More informationUSER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch
USER MANUAL REFLEX SIGHT Ultra Shot Z Series English / Francais / Español / Deutsch ABOUT SIGHTMARK Sightmark offers a wide range of products that include red dot scopes, reflex sights, rangefinders, riflescopes,
More informationState Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual
State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant Night Sight PN-6K Servise Manual Contents 1. General directions 4 2. Specifications 5 3. Delivery set 6 4. Safety regulations
More informationOnline Assembly Guide : 4.5 inch Reflector Telescope
Online Assembly Guide : 4.5 inch Reflector Telescope INTRODUCTION Congratulations! You have bought a wonderful telescope. This is a precision optical instrument, and you have many wonderful evenings of
More informationCONTENTS. Batteries. La Crosse Technology, Ltd Page 1
515-1316 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader CONTENTS
More information???? The Vortex Crossfire II Riflescopes
OWNER S 1-Inch Tubes MANUAL???? The Vortex Crossfire II Riflescopes Specifically designed for discriminating hunters and shooters, the Crossfire II series of riflescopes offer the highest levels of performance
More informationWARNING: Ensure weapon is not loaded prior to mounting riflescope.
Xp8 The Atibal 1-8x24 Riflescope At Atibal, we continuously strive to bring you high-quality, high-performance, precision optics at a price you can afford. The 1-8x24 offers speed and versatility for AR
More informationColumbia University Astronomy Big Dome Telescope Start up/shut Down
Columbia University Astronomy Big Dome Telescope Start up/shut Down Start Up 1. Get the Eyepieces: Go into the transit room and get any eyepieces you will need. The telescope in the big dome takes both
More informationInstructions Manual Zoomion Apollo 80
Instructions Manual Zoomion Apollo 80 English version 7.2015 Rev A 1 The Zoomion Apollo 80 Figure 1. Parts description. Congratulations on the purchase of the new Zoomion Apollo 80. This telescope will
More informationInstructions Manual Omegon Dobson Advanced 203
Instructions Manual Omegon Dobson Advanced 203 English version 10.2015 Rev A 1 The Omegon Advanced Dobson 203 Congratulations on the purchase of the new Omegon Advanced Dobson 203 telescope. This telescope
More informationRichter Optica. Instructions for Model: S850 Stereo Zoom Microscope
Richter Optica info@richter-optica.com Instructions for Model: S850 Stereo Zoom Microscope Microscope Head Focus Knob Stage Clips Zoom Knob C-Mount Adapter Eyepiece Focusing Holder Focusing Holder Set
More informationPulse Laser Station NPL-302 Series
Pulse Laser Station NPL-302 Series Instruction Manual NPL-332 NPL-352 NPL-362 H163E 05.10.TF.9 Contact Information Nikon-Trimble Co. Limited Copyright and Trademarks 2005, Nikon-Trimble Co. Limited. All
More informationAccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130
AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount Installation and User Manual Product #3130 ioptron Corporation, 6E Gill Street, Woburn, MA 01801 www.ioptron.com ioptron
More informationOASIS WIRELESS WEATHER STATION
User Manual 3910-B Royal Avenue, Simi Valley, Ca 93063 805-527-4498 RMIS Part No. 500760 TABLE OF CONTENTS INTRODUCTION General Description 3 General Precautions 3 INSTALLATION Base Preparation 6 Tower
More informationNational Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)
National Optical & Scientific Instrument Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR SHOP MICROSCOPES MODEL NUMBERS 186 187 188 189 National
More informationHD Gen II 1 6x24 Riflescope. The Vortex Razor
Razor HD Gen II 1-6x24 Specifications Waterproof Yes Fogproof Argon Gas Tube Diameter 30 mm Length 10.0 Inches (254 mm) Mounting Length 6.0 Inches (162.6 mm) Weight 18.4 Ounces (521.6 g) Eye Relief 4.0
More informationThe Vortex Razor HD Gen II 1 6x24 Riflescope
The Vortex Razor HD Gen II 1 6x24 Riflescope At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. We carefully built the Razor HD Gen II riflescope
More informationDETERMINATION OF AREA OF POLYGON BY CHAIN AND CROSS STAFF SURVEY 1. AIM:
Expt. No: 2 Date: DETERMINATION OF AREA OF POLYGON BY CHAIN AND CROSS STAFF SURVEY 1. AIM: To determine the area of a given field with define boundary by conducting cross staff survey. 2. INSTRUMENTS REQUIRED:
More informationSelf-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual
Self testing Prevectron 2 Millenium Lightning Conductor ENGLISH Self-Testing Prevectron 2 Millenium Lightning Conductor Set-up and Installation Manual S6.60T S4.50T S3.40T N.B. : Information and Specifications
More informationSCHIEBER TELESCOPES. Unique, High-Quality Telescopes
SCHIEBER TELESCOPES Unique, High-Quality Telescopes 3.5 Refractor Astrophotography Bundle - Strike 90 PLUS Telescope Assembly Instructions and Digital Eyepiece Camera Instructions. (1) telescope assembly
More informationSET5W WATERPROOF TOTAL STATION
SURVEYING INSTRUMENTS SOKKIA SET5W WATERPROOF TOTAL STATION Water, water everywhere... but not a drop of worry. The waterproof SET5W is ruggedly built to withstand harsh operating conditions. Being fully
More informationRT-6 Riflescopes. User Guide
RT-6 Riflescopes User Guide This user guide includes information for low-magnification RT-6 riflescopes. Please review thoroughly, and pay close attention to the details pertaining to your specific riflescope