1 PH2 page 1 DISPERSION OF A GLASS PRISM OBJECTIVE The objective of this experiment is to analyze the emission spectrum of helium and to analyze the dispersion of a glass prism by measuring the index of refraction for different colours in this spectrum. INTRODUCTION Light is emitted or absorbed when electrons change their orbit within an individual atom. Therefore, a spectrometer can be used to investigate the structure of atoms and also to determine which atoms are present in a substance. In this experiment a spectrometer will be used to examine the visible spectrum emitted by helium in a discharge tube and to determine the index of refraction of a glass prism as a function of the wavelength and the associated dispersion. In principle, a spectrometer is a very simple scientific instrument: It can bend a beam of light with a prism. If the beam is composed of more than one color of light, a spectrum is formed, since the various colors are refracted to different angles. The result is a spectral "fingerprint," which carries a wealth of information about the substance from which the light is emitted. In its simplest form, a spectrometer is nothing more than a prism and a protractor. However, because of the need for very sensitive detection and precise measurement, a real spectrometer is a bit more complicated. As shown in Figure 1, a spectrometer consists of three basic components; a collimator, a prism, and a telescope. Adjustable Collimator Slit Collimator A Prism Angle of Deviation Telescope Light Source Eye Piece Figure 1. Spectrometer Diagram The light to be analyzed enters the collimator through a narrow slit positioned at the focal point of the collimator lens. The light leaving the collimator is therefore a thin, parallel beam, which ensures that all the light from the slit strikes the prism at the same angle of incidence. This is necessary if a sharp image is to be formed. The prism bends the beam of light. If the beam is composed of many different colours, each colour is refracted to a different angle. The telescope can be rotated to collect the refracted light at very precisely measured angles. With the telescope focused at infinity and positioned at an angle to collect the light of a particular color, a precise image of the collimator slit can be seen. For example,

2 PH2 page 2 when the telescope is at one angle of rotation, the viewer might see a red image of the slit, at another angle a green image, and so on. By rotating the telescope, the slit images corresponding to each constituent color can be viewed and the angle of refraction for each image can be measured. Slit Image Slit Image Vertical Cross-Hair Vertical Cross-Hair Figure 2. Telescope View at Different Angles If the index of refraction of the prism for each colour in the light is known, then these measured angles can be used to determine the wavelengths that are present in the light. However, if the wavelengths of the colours in the light are known, then the measured angles can be used to determine the index of refraction of each colour. For a prism, the angle of refraction is not directly proportional to the wavelength of the light. The Angle of Minimum Deviation The angle of deviation for light traversing a prism is shown in Figure 3. For each wavelength of light traversing a given prism, there is a characteristic angle of incidence for which the angle of deviation is a minimum. Figure 3: Reading the Angle of Deviation This angle depends only on the index of refraction of the prism and the angle (labeled A in Figure 3) between the two sides of the prism traversed by the light. The relationship between these variables is given by the equation: (Eq. 1) where n is the index of refraction of the prism for a given wavelength; A is the angle between the sides of the prism traversed by the light; and D min is the angle of minimum deviation. Since n varies

3 PH2 page 3 with wavelength, the angle of minimum deviation also varies, but it is constant for any particular wavelength. EQUIPMENT The spectrometer includes the following equipment: Prism Figure 4. The Spectrometer Collimator and Telescope Both the collimator and the telescope have 178 mm focal length, achromatic objectives, and clear apertures with 32 mm diameters. The telescope has a 15X Ramsden eyepiece with a glass, cross-hair graticule. The collimator is fitted with a 6 mm long slit of adjustable width. Both the collimator and the telescope are aligned so that their optical axes are perpendicular to their axis of rotation. Rotating Bases The telescope and the spectrometer table are mounted on independently rotating bases. Vernier scales provide measurements of the relative positions of these bases to within 20 minutes of arc (or 0.1 degree of arc depending on the model; see the two examples reading the vernier below). The rotation of each base is controlled with a lock-screw and fine adjust knob (see figure 4 above). With the lock-screw released, the base is easily rotated by hand. With the lock-screw tight, the fine adjust knob can be used for more precise positioning. Spectrometer Table The spectrometer table is fixed to its rotating base with a thumbscrew, so table height is adjustable. Three leveling screws on the underside of the table are used to adjust the optical alignment. (The table must be level with respect to the optical axes of the collimator and telescope if the prism is to retain its alignment for all positions of the telescope.) Thumbscrews are used to attach the prism clamp and the grating mount to the table, and reference lines are etched in the table for easy alignment.

4 PH2 page 4 PRELIMINARY ADJUSTMENTS The spectrometer may need adjusting before being used. The purpose of these preliminary adjustments is to get parallel rays to pass from the collimator through the prism and to the telescope. FOCUSING THE SPECTROMETER The next three steps of the adjustments must be carried out in the order indicated. Once completed properly, these adjustments should not need further attention for the duration of the experiment. (a) ADJUSTMENT OF THE CROSS-HAIRS While looking through the telescope, slide the eyepiece in and out until the crosshairs come into sharp focus. Loosen the graticule lock ring, and rotate the graticule until one of the cross-hairs is vertical. Retighten the lock ring and then refocus if necessary. (b) ADJUSTMENT OF THE TELESCOPE Point the telescope toward a distant object. Adjust the focusing screw until the distant object is seen clearly. There should be no parallax between the cross-hairs and the image of the distant object. (c) ADJUSTMENT OF THE COLLIMATOR The collimator resembles the telescope except it carries an adjustable slit at one end. Place a light source close to the slit. Turn the telescope into line with the collimator as in Figure 5. Looking through the telescope, adjust the focus of the collimator and, if necessary, the rotation of the telescope until the slit comes into sharp focus. There should be no parallax between this image of the slit and the cross-hairs Do not change the focus of the telescope.. Figure 5: Alignment of the Telescope directly opposite the Collimator Tighten the telescope rotation lock-screw, then use the fine adjust knob to align the vertical line of the graticule with the fixed edge of the slit. If the slit is not vertical, loosen the slit lock ring, realign the slit, and retighten the lock ring. Adjust the slit width for a clear, bright image. Measurements of the refraction angle are always made with the graticule line aligned along the fixed edge of the slit, so a very narrow slit is not necessarily advantageous.

5 PH2 page 5 READING THE VERNIER SCALE EXAMPLE 1 The vernier in this example will allow you to read the angle to the nearest half a minute. Observe that the main scale divides one complete a revolution into 360. Each degree on the main scale is in turn divided into three parts (20 minutes each) or two parts (30 minutes each) depending on the spectrometer type. The sliding scale (or the vernier) is used to measure to the nearest minute or better. The vernier scale will thus have either 20 or 30 major divisions, and perhaps in between divisions indicating half minute readings. The divisions of the vernier scale are arranged such that at any given time only one of the divisions will be usually perceived as being closest to the perfect alignment with a main scale line. The exception being the first and last vernier lines which can both align with the main scale at the same time. To take a reading, first take the main scale reading immediately bellow the position of the zero line of the vernier scale. This main scale reading will be a multiple of 20 minutes (or 30 minutes for some spectrometers). The vernier scale is then read noting which line on the vernier scale most closely aligns with a main scale line. The vernier scale reading is then added to the main scale reading. Figure 5 shows an example reading with a vernier scale that is divided into twenty minute divisions with half divisions in between. The main scale reading is to , and the vernier scale reads Thus the complete reading is Closest to perfect alignment Figure 6: Vernier Reading Example 1 Main scale divides one complete revolution into and the vernier has 20 major divisions with half divisions in between. In this example, the vernier line closest to perfect alignment with the main scale line reads 12 EXAMPLE 2 In this model, the main scale is divided into and the vernier has 10 divisions. Therefore, you will be able to read the angle to the nearest 0.1 of a degree. Begin by reading the main scale directly below zero on the vernier scale: in the example in figure 6 below, this is 19 o ; use the next smallest number below the line pointed-to by the small red vertical arrow in figure 7 below. Next, the fractional part can determined using the vernier s auxiliary scale. Simply follow the lines across on the vernier scale (the outside scale) until you locate the only one which best lines-up with a line on the circular inner scale. In this example, the eighth line (corresponding to 0.8 o ) is best aligned with a line on the inner ring. On either side of this line (e.g. 0.7 or 0.9) you ll see that the lines do not match. Finally we add our integer angle of 19 o to our vernier reading of 0.8 o to get 19.8 o.

6 PH2 page 6 Closest to perfect alignment Figure 7: Vernier reading, Example 2 Main scale divides one complete revolution into and the vernier has 10 divisions. The vernier line closest to perfect alignment with the main scale line reads 0.8 PROCEDURE: MEASURING THE ANGLE OF MINIMUM DEVIATION 1. Place the light source a few centimeters behind the slit of the collimator. 2. Once you have aligned and focused the spectrometer as described earlier, place the prism on the spectrometer table so that the incident light passes through it. It may be helpful to partially darken the room. 3. It is generally possible to see the refracted light with the naked eye. Locate the general direction to which the light is refracted, and then align the telescope and spectrometer table base so the slit image can be viewed through the telescope. 4. While looking through the telescope, rotate the spectrometer table slightly back and forth. Notice that the angle of refraction for the spectral line under observation changes. Rotate the spectrometer table until this angle is a minimum, and then rotate the telescope to align the vertical cross-hair with the fixed edge of the slit image as in Figure 8 below. Use the fine adjust knobs to make these adjustments as precisely as possible, then measure the telescope angle θ min using the vernier scale. Slit Image Vertical Cross-Hair Figure 8: View through the telescope

7 PH2 page 7 5. Without changing the rotation of the spectrometer table, remove the prism and rotate the telescope to align the cross-hair with the fixed edge of the unrefracted beam. Measure the angle θ on the vernier scale. The difference between this angle and that recorded for the refracted spectral line in step 4, is the angle of minimum deviation. Notice that, since the determination of the angle of minimum deviation for each spectral line requires rotational adjustments of the spectrometer table, the angle of the undeflected beam must be remeasured for each line. 6. The table below gives the wavelengths (in nm) of the spectrum lines that can be seen clearly in the helium discharge. Record in the same column, the values of the θ 0 (the vernier angle with the telescope and collimator axis aligned), θ min (the vernier reading at minimum deviation). Table of observations: Dispersion of Helium Light Through A Glass Prism. Colour of the Lines in the Helium Discharge Wavelength (nm) weak red 707 strong red 668 yellow 588 green 502 blue-green 492 blue 471 violet 447 A ( o ) θ 0 θ min D min = θ min θ 0 60 o 7. Repeat steps 3 to 5 above for five other lines of the spectrum and record your observations in the table above. DATA ANALYSIS 1. For each of the analyzed lines calculate the angle of minimum deviation D min, and then the index of refraction n, of the glass of the prism to four significant digits using the Eq. 1. Record your results in the table above 2. Using the values in this table, plot a graph of the index of refraction vs. the wavelength of these spectral lines. Analyze and comment on the shape of this graph. 3. Could you use this graph to predict the index of refraction of the glass prism for a different colour, not present in the current spectrum?

Instruction Manual and Experiment Guide for the PASCO scientific Model SP E 2/96 STUDENT SPECTROMETER. Copyright January 1991 $7.

Instruction Manual and Experiment Guide for the PASCO scientific Model SP E 2/96 STUDENT SPECTROMETER. Copyright January 1991 $7. Instruction Manual and Experiment Guide for the PASCO scientific Model SP-9268 012-02135E 2/96 STUDENT SPECTROMETER Copyright January 1991 $7.50 012-02135E Spectrometer Table of Contents Section Page

More information

THE DIFFRACTION GRATING SPECTROMETER

THE DIFFRACTION GRATING SPECTROMETER Purpose Theory THE DIFFRACTION GRATING SPECTROMETER a. To study diffraction of light using a diffraction grating spectrometer b. To measure the wavelengths of certain lines in the spectrum of the mercury

More information

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 14. The Atomic Spectrum of Hydrogen

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 14. The Atomic Spectrum of Hydrogen Laboratory Section: Last Revised on September 21, 2016 Partners Names: Grade: EXPERIMENT 14 The Atomic Spectrum of Hydrogen 0. Pre-Laboratory Work [2 pts] 1. You will be using a diffraction grating in

More information

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra Ph 3455/MSE 3255 Experiment 2: Atomic Spectra Background Reading: Tipler, Llewellyn pp. 163-165 Apparatus: Spectrometer, sodium lamp, hydrogen lamp, mercury lamp, diffraction grating, watchmaker eyeglass,

More information

Laboratory #29: Spectrometer

Laboratory #29: Spectrometer INDIANA UNIVERSITY, DEPARTMENT OF PHYSICS, P309 LABORATORY Laboratory #29: Spectrometer Goal: Learn to adjust an optical spectrometer, use a transmission grating to measure known spectral lines of mercury,

More information

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P Optics Spectrometer Prism spectrometer LD Physics Leaflets P5.7.1.1 Measuring the line spectra of inert gases and metal vapors using a prism spectrometer Objects of the experiment Adjusting the prism spectrometer.

More information

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009 Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009 Name Section Return this spreadsheet to your TA that will use it to score your lab. To receive full credit you must use complete sentences and

More information

EXPERIMENT 12 THE GRATING SPECTROMETER AND ATOMIC SPECTRA

EXPERIMENT 12 THE GRATING SPECTROMETER AND ATOMIC SPECTRA OBJECTIVES Learn the theory of the grating spectrometer Observe the spectrum of mercury and hydrogen Measure the grating constant of a diffraction grating Measure the Rydberg Constant EXPERIMENT THE GRATING

More information

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types. Physics 2310 Lab 2: The Dispersion of Optical Glass Dr. Michael Pierce (Univ. of Wyoming) Based on a lab by Dr. M. Kruger (Univ. of Missouri, Kansas City) Purpose: The purpose of this lab is to introduce

More information

The Grating Spectrometer and Atomic Spectra

The Grating Spectrometer and Atomic Spectra PHY 192 Grating Spectrometer Spring 2012 1 The Grating Spectrometer and Atomic Spectra Introduction In the previous experiment diffraction and interference were discussed and at the end a diffraction grating

More information

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008 Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008 Name Section This sheet is the lab document your TA will use to score your lab. It is to be turned in at the end of lab. To receive full credit

More information

Atomic emission spectra experiment

Atomic emission spectra experiment Atomic emission spectra experiment Contents 1 Overview 1 2 Equipment 1 3 Measuring the grating spacing using the sodium D-lines 4 4 Measurement of hydrogen lines and the Rydberg Constant 5 5 Measurement

More information

The Grating Spectrometer and Atomic Spectra

The Grating Spectrometer and Atomic Spectra PHY 192 Grating Spectrometer 1 The Grating Spectrometer and Atomic Spectra Introduction In the previous experiment diffraction and interference were discussed and at the end a diffraction grating was introduced.

More information

EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer

EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer Debangshu Mukherjee B.Sc Physics,1st year Chennai Mathematical Institute 17.10.008 1 Aim of Experiment

More information

Any first year text, sections on atomic structure, spectral lines and spectrometers

Any first year text, sections on atomic structure, spectral lines and spectrometers Physics 33 Experiment 5 Atomic Spectra References Any first year text, sections on atomic structure, spectral lines and spectrometers Any modern physics text, eg F.K. Richtmeyer, E.H. Kennard and J.N.

More information

LAB 10: OPTICAL MATERIALS AND DISPERSION I

LAB 10: OPTICAL MATERIALS AND DISPERSION I OPTI 202L - Geometrical and Instrumental Optics Lab LAB 10: OPTICAL MATERIALS AND DISPERSION I 10-1 Measuring the refractive index of a material is one of the most fundamental optical measurements, and

More information

Experiment #4: Optical Spectrometer and the Prism Deviation

Experiment #4: Optical Spectrometer and the Prism Deviation Experiment #4: Optical Spectrometer and the Prism Deviation Carl Adams October 2, 2011 1 Purpose In the first part of this lab you will set up and become familiar with an optical spectrometer. In the second

More information

Dispersion of light by a prism

Dispersion of light by a prism Dispersion of light by a prism Aim: (i) To calculate refractive index µ of a prism for various wavelengths (λ) of Hg and to find dispersive power of the material of the prism (ii) To plot µ-/λ curve and

More information

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating. 12. Diffraction grating OBJECT To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating. INTRODUCTION: Consider a light beam transmitted through an aperture

More information

The Quantum Model of the Hydrogen Atom

The Quantum Model of the Hydrogen Atom Physics 109 Science 1 Experiment 1 1 The Quantum Model of the Hydrogen Atom In this experiment you will use a spectrometer to determine the wavelengths of the visible lines of atomic hydrogen. The goal

More information

Atomic Spectra HISTORY AND THEORY

Atomic Spectra HISTORY AND THEORY Atomic Spectra HISTORY AND THEORY When atoms of a gas are excited (by high voltage, for instance) they will give off light. Each element (in fact, each isotope) gives off a characteristic atomic spectrum,

More information

ATOMIC SPECTRA. Objective:

ATOMIC SPECTRA. Objective: 1 ATOMIC SPECTRA Objective: To measure the wavelengths of visible light emitted by atomic hydrogen and verify the measured wavelengths against those predicted by quantum theory. To identify an unknown

More information

Using the Spectrometer

Using the Spectrometer Using the Spectrometer Introduction When an atom is stimulated it can respond by emitting a spectrum of light. The spectrum comprises discrete wavelengths whose values are characteristic of the particular

More information

Determination of Cauchy s Contants

Determination of Cauchy s Contants 8. Determination of Cauchy s Contants 8.1 Objective: To determine Cauchy s Constants using a prism and spectrometer. Apparatus: Glass prism, spectrometer and mercury vapour lamp. 8. Theory: The wavelength

More information

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student Operating Instructions Spectro-Goniometer Student 1 Functional Elements Figure 1: Spectro-Goniometer Student 1. Adjustable entrance slit, holding screw for slit cover 2. Lock ring fixing entrance slit

More information

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT Physics 211 E&M and Quantum Physics Spring 2018 Lab #9: Diffraction Spectroscopy Lab Writeup Due: Mon/Wed/Thu/Fri, April 30/ May 2/3/4, 2018 Background All

More information

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION References for Fraunhofer Diffraction 1. Jenkins and White Fundamentals of Optics. Chapters on Fraunhofer diffraction and

More information

Chapter 4. Dispersion of Glass. 4.1 Introduction. 4.2 Apparatus

Chapter 4. Dispersion of Glass. 4.1 Introduction. 4.2 Apparatus Chapter 4 Dispersion of Glass 4.1 Introduction This experiment will develop skills in choosing a suitable fit for data and plotting the resulting curve. Curve fitting will count for a big chunk of the

More information

Physics 24, Spring 2007 Lab 2 - Complex Spectra

Physics 24, Spring 2007 Lab 2 - Complex Spectra Physics 24, Spring 2007 Lab 2 - Complex Spectra Theory The optical spectra of isolated atoms consist of discrete, unequally spaced lines. This fact could not be understood on the basis of classical atomic

More information

Physics 23 Fall 1998 Lab 4 - The Hydrogen Spectrum

Physics 23 Fall 1998 Lab 4 - The Hydrogen Spectrum Physics 3 Fall 998 Lab 4 - The Hydrogen Spectrum Theory In the late 800's, it was known that when a gas is excited by means of an electric discharge and the light emitted is viewed through a diffraction

More information

EXPERIMENT 14. The Atomic Spectrum of Hydrogen

EXPERIMENT 14. The Atomic Spectrum of Hydrogen Name: Laboratory Section: Laboratory Section Date: Partners Names: Grade: Last Revised on March 18, 2003 EXPERIMENT 14 The Atomic Spectrum of Hydrogen 0. Pre-Laboratory Work [2 pts] 1. You will be using

More information

Visible Spectrometer

Visible Spectrometer Visible Spectrometer Experiment VIS University of Florida Department of Physics PHY4803L Advanced Physics Laboratory Objective The Balmer spectral lines from a hydrogen discharge lamp are observed with

More information

Experiment #5: Cauchy s Formula

Experiment #5: Cauchy s Formula Experiment #5: Cauchy s Formula Carl Adams October 14, 2011 1 Purpose This experiment is a continuation of Experiment #4. It is assumed you have an aligned spectrometer. 2 Safety/Protocol 1. The gas discharge

More information

Atomic Spectra. d sin θ = mλ (1)

Atomic Spectra. d sin θ = mλ (1) Atomic Spectra Objectives: To measure the wavelengths of visible light emitted by atomic hydrogen and verify that the measured wavelengths obey the empirical Rydberg formula. To observe emission spectra

More information

PC1144 Physics IV. Atomic Spectra

PC1144 Physics IV. Atomic Spectra PC1144 Physics IV Atomic Spectra 1 Objectives Investigate how well the visible light wavelengths of hydrogen predicted by the Bohr theory agree with experimental values. Determine an experimental value

More information

Visible Spectrometer

Visible Spectrometer Visible Spectrometer Experiment VIS University of Florida Department of Physics PHY4803L Advanced Physics Laboratory Objective The Balmer spectral lines from a hydrogen discharge lamp are observed with

More information

DISPERSION AND SPECTRA CHAPTER 20

DISPERSION AND SPECTRA CHAPTER 20 CHAPTER 20 DISPERSION AND SPECTRA 20.1 DISPERSION As mentioned earlier, the refractive index of a material depends slightly on the wavelength of light. The relation between the two may be approximately

More information

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P )

Dispersion and resolving power of the prism and grating spectroscope (Item No.: P ) Dispersion and resolving power of the prism and grating spectroscope (Item No.: P2210300) Curricular Relevance Area of Expertise: Physics Education Level: University Topic: Light and Optics Subtopic: Diffraction

More information

10. Wavelength measurement using prism spectroscopy

10. Wavelength measurement using prism spectroscopy Spk 0. Wavelength measurement using prism spectroscopy 0. Introduction The study of emitted spectra of electromagnetic waves by excited atoms makes for one of the most important methods to investigate

More information

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY SPECTROSCOPY SYNOPSIS: In this lab you will eplore different types of emission spectra, calibrate a spectrometer using the spectrum of a known element, and use your calibration to identify an unknown element.

More information

The Emission Spectra of Light

The Emission Spectra of Light The Emission Spectra of Light Objectives: Theory: 1.... measured the wavelength limits of the color bands in the visible spectrum, 2.... measured the wavelengths of the emission lines of the hydrogen Balmer

More information

Rydberg constant from atomic spectra of gases

Rydberg constant from atomic spectra of gases Page 1 of 8 Rydberg constant from atomic spectra of gases Objective - Calibrating a prism spectrometer to convert the scale readings in wavelengths of spectral lines. - Observing the Balmer series of atomic

More information

Dispersion of Glass Introduction Apparatus Theory

Dispersion of Glass Introduction Apparatus Theory Dispersion of Glass Introduction This experiment will develop skills in aligning and using a spectrometer to measure dispersion of glass, and choosing a suitable fit for data and plotting the resulting

More information

Note: Common units for visible light wavelengths are the Angstrom (Å) and the nanometer (nm).

Note: Common units for visible light wavelengths are the Angstrom (Å) and the nanometer (nm). Modern Physics Laboratory Spectra and Spectrometers, Balmer Spectrum of Hydrogen In this experiment, we display continuous and discrete emission spectra and explore the use of several types of spectrometers.

More information

University of Massachusetts, Amherst

University of Massachusetts, Amherst PHYSICS 286: Modern Physics Laboratory SPRING 2010 (A. Dinsmore and K. Kumar) Feb 2009 Experiment 4: THE FRANCK HERTZ EXPERIMENT Electronic Excitations of a Gas, and Evidence for the Quantization of Atomic

More information

Spectrum of Hydrogen. Physics 227 Lab

Spectrum of Hydrogen. Physics 227 Lab Introduction In today's lab you will be dealing with an area of physics called quantum mechanics. The only quantum mechanical idea that you will be using today is that electrons in an atom can exist only

More information

Lab report 30 EXPERIMENT 4. REFRACTION OF LIGHT

Lab report 30 EXPERIMENT 4. REFRACTION OF LIGHT 30 EXPERIMENT 4. REFRACTION OF LIGHT Lab report Go to your course homepage on Sakai (Resources, Lab templates) to access the online lab report worksheet for this experiment. The worksheet has to be completed

More information

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp. ATOMIC SPECTRA Objective: To measure the wavelengths of visible light emitted by atomic hydrogen and verify the measured wavelengths against those predicted by quantum theory. To identify elements through

More information

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes SCHIEBER TELESCOPES Unique, High-Quality Telescopes 3.5 Refractor Astrophotography Bundle - Strike 90 PLUS Telescope Assembly Instructions and Digital Eyepiece Camera Instructions. (1) telescope assembly

More information

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s PHYS 1040 - General Physics II Lab The Balmer Series for Hydrogen Source Purpose: The purpose of this experiment is to analyze the emission of light from a hydrogen source and measure and the wavelengths

More information

AS 101: Day Lab #2 Summer Spectroscopy

AS 101: Day Lab #2 Summer Spectroscopy Spectroscopy Goals To see light dispersed into its constituent colors To study how temperature, light intensity, and light color are related To see spectral lines from different elements in emission and

More information

HYDROGEN SPECTRUM. Figure 1 shows the energy level scheme for the hydrogen atom as calculated from equation. Figure 1 Figure 2

HYDROGEN SPECTRUM. Figure 1 shows the energy level scheme for the hydrogen atom as calculated from equation. Figure 1 Figure 2 15 Jul 04 Hydrogen.1 HYDROGEN SPECTRUM In this experiment the wavelengths of the visible emission lines of hydrogen (Balmer series) will be measured and compared to the values predicted by Bohr s quantum

More information

EXPERIMENT NO. 6. OBJECT: To determine the wavelength of any three lines of mercury light by diffraction grating in1 st and 2 nd order spectrum.

EXPERIMENT NO. 6. OBJECT: To determine the wavelength of any three lines of mercury light by diffraction grating in1 st and 2 nd order spectrum. EXPEIMENT NO. 6 OBJECT: To determine the wavelength of any three lines of mercury light by diffraction grating in1 st and 2 nd order spectrum. APPAATUS: A diffraction grating, Spectrometer, spirit level,

More information

Experiment #4 Nature of Light: Telescope and Microscope and Spectroscope

Experiment #4 Nature of Light: Telescope and Microscope and Spectroscope Experiment #4 Nature of Light: Telescope and Microscope and Spectroscope In this experiment, we are going to learn the basic principles of the telescope and the microscope that make it possible for us

More information

DAY LABORATORY EXERCISE: SPECTROSCOPY

DAY LABORATORY EXERCISE: SPECTROSCOPY AS101 - Day Laboratory: Spectroscopy Page 1 DAY LABORATORY EXERCISE: SPECTROSCOPY Goals: To see light dispersed into its constituent colors To study how temperature, light intensity, and light color are

More information

Emission Spectrum of Atomic Gases. Prelab Questions

Emission Spectrum of Atomic Gases. Prelab Questions Emission Spectrum of Atomic Gases Prelab Questions Before this coming to this lab, please review your text for the physics of the spectrum of visible light and of diffraction grating spectrometer.. Which

More information

L-7 SPECTROMETER. (3) To plot a dispersion curve for the glass prism, and use the curve for the identification of unknown wavelengths.

L-7 SPECTROMETER. (3) To plot a dispersion curve for the glass prism, and use the curve for the identification of unknown wavelengths. http://www.lhup.edu/~dsimanek/scenario/labman3/spectrom.htm 1. PURPOSE: L-7 SPECTROMETER (1) To learn the use of a prism spectrometer. (2) To accurately determine the index of refraction of a glass prism

More information

Diffraction of light by a grating

Diffraction of light by a grating (ta initials) first name (print) last name (print) brock id (ab17cd) (lab date) Experiment 5 Diffraction of light by a grating In this Experiment you will learn the geometical analysis of a diffraction

More information

Atomic spectra of one and two-electron systems

Atomic spectra of one and two-electron systems Atomic spectra of one and two-electron systems Key Words Term symbol, Selection rule, Fine structure, Atomic spectra, Sodium D-line, Hund s rules, Russell-Saunders coupling, j-j coupling, Spin-orbit coupling,

More information

Experiment 24: Spectroscopy

Experiment 24: Spectroscopy Experiment 24: Spectroscopy Figure 24.1: Spectroscopy EQUIPMENT High Voltage Power Supply Incandescent Light Source (3) Gas Discharge Tubes: 1. Helium 2. Hydrogen 3. Unknown Element Spectrometer Felt (1)

More information

PHYSICS 116 SPECTROSCOPY: DETERMINATION OF THE WAVELENGTH OF LIGHT

PHYSICS 116 SPECTROSCOPY: DETERMINATION OF THE WAVELENGTH OF LIGHT Name Date Lab Time Lab TA PHYSICS 116 SPECTROSCOPY: DETERMINATION OF THE WAVELENGTH OF LIGHT I. PURPOSE To use a diffraction grating to investigate the spectra produced by several unknown gas discharge

More information

Instruments and Related Topics

Instruments and Related Topics 1. Traveling Microscope The traveling microscope [Fig.1] is an instrument well-suited for the purpose of measuring small vertical or horizontal distances with high accuracy. It consists of a compound microscope

More information

Pre-lab Quiz/PHYS 224. Your name Lab section

Pre-lab Quiz/PHYS 224. Your name Lab section Pre-lab Quiz/PHYS 224 THE DIFFRACTION GRATING AND THE OPTICAL SPECTRUM Your name Lab section 1. What are the goals of this experiment? 2. If the period of a diffraction grating is d = 1,000 nm, where the

More information

EXPERIMENT 17: Atomic Emission

EXPERIMENT 17: Atomic Emission EXPERIMENT 17: Atomic Emission PURPOSE: To construct an energy level diagram of the hydrogen atom To identify an element from its line spectrum. PRINCIPLES: White light, such as emitted by the sun or an

More information

Atomic and nuclear physics

Atomic and nuclear physics Atomic and nuclear physics Atomic shell Normal Zeeman effect LEYBOLD Physics Leaflets Observing the normal Zeeman effect in transverse and longitudinal Objects of the experiment Observing the line triplet

More information

DIFFRACTION GRATING. OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths.

DIFFRACTION GRATING. OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths. DIFFRACTION GRATING OBJECTIVE: To use the diffraction grating in the formation of spectra and in the measurement of wavelengths. THEORY: The operation of the grating is depicted in Fig. 1 on page Lens

More information

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer. Experiment 9 Emission Spectra 9.1 Objectives By the end of this experiment, you will be able to: measure the emission spectrum of a source of light using the digital spectrometer. find the wavelength of

More information

Phys102 Lecture Diffraction of Light

Phys102 Lecture Diffraction of Light Phys102 Lecture 31-33 Diffraction of Light Key Points Diffraction by a Single Slit Diffraction in the Double-Slit Experiment Limits of Resolution Diffraction Grating and Spectroscopy Polarization References

More information

Atomic Spectra 1. Name Date Partners ATOMIC SPECTRA

Atomic Spectra 1. Name Date Partners ATOMIC SPECTRA Atomic Spectra 1 Name Date Partners ATOMIC SPECTRA Sodium Mercury Lithium Hydrogen Atomic line spectra are characteristic for every element. These are emission spectra (without color). OBJECTIVES Review

More information

UNIT-5 EM WAVES UNIT-6 RAY OPTICS

UNIT-5 EM WAVES UNIT-6 RAY OPTICS UNIT-5 EM WAVES 2 Marks Question 1. To which regions of electromagnetic spectrum do the following wavelengths belong: (a) 250 nm (b) 1500 nm 2. State any one property which is common to all electromagnetic

More information

You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp)

You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp) You Are the Spectrometer! A Look Inside Astronomy's Essential Instrument (Robert B. Friedman & Matthew K. Sharp) Introduction Astronomy is a unique science because unlike many of the other sciences, the

More information

EXPERIMENT 12 THE WAVELENGTH OF LIGHT; THE DIFFRACTION GRATING

EXPERIMENT 12 THE WAVELENGTH OF LIGHT; THE DIFFRACTION GRATING EXPERIMENT 12 THE WAVELENGTH OF LIGHT; THE DIFFRACTION GRATING INTRODUCTION: One of the most fascinating chapters in the history of physics has been the search for an understanding of the true nature of

More information

Science Lab I Properties of Light

Science Lab I Properties of Light Art & Science of Light Fall 2007 Science Lab I Properties of Light Prepared by: Dr. Dharshi Bopegedera 1 Using the Filtergraph (15 minutes) 1. Turn on the filtergraph, place a card on it and look at the

More information

LAB 12 ATOMIC SPECTRA

LAB 12 ATOMIC SPECTRA 217 Name Date Partners LAB 12 ATOMIC SPECTRA OBJECTIVES Review the quantum nature of light and how light photons are produced in atoms. Learn to use an optical spectrometer to measure light wavelengths.

More information

Protokoll. Grundpraktikum II - Optical Spectroscopy

Protokoll. Grundpraktikum II - Optical Spectroscopy Protokoll Grundpraktikum II - Optical Spectroscopy 1 Elaboration 1.1 Optical Spectroscopy Student: Hauke Rasch, Martin Borchert Tutor: Madsen Date: 22.October2014 This experiment is about the fundamental

More information

Atomic Emission Spectra

Atomic Emission Spectra Atomic Emission Spectra Objectives The objectives of this laboratory are as follows: To build and calibrate a simple meter-stick spectroscope that is capable of measuring wavelengths of visible light.

More information

Experiment 7: Spectrum of the Hydrogen Atom

Experiment 7: Spectrum of the Hydrogen Atom Experiment 7: Spectrum of the Hydrogen Nate Saffold nas2173@columbia.edu Office Hour: Mondays, 5:30-6:30PM INTRO TO EXPERIMENTAL PHYS-LAB 1493/1494/2699 Introduction The physics behind: The spectrum of

More information

Introduction to Telescopes Pre-lab

Introduction to Telescopes Pre-lab AST 114 Spring 2005 Introduction to Telescopes Introduction to Telescopes Pre-lab 1. Read through the "Parts of a Telescope" section of the lab. You may be asked to point out the different parts of the

More information

Laboratory Exercise 7 MEASUREMENTS IN ASTRONOMY

Laboratory Exercise 7 MEASUREMENTS IN ASTRONOMY Laboratory Exercise 7 MEASUREMENTS IN ASTRONOMY Introduction Part A: The angular resolution of telescopes For astronomical observations, reflecting telescopes have replaced the refracting type of instrument.

More information

Obtain an optical "bench" setup (there should be three sliding mounts on the calibrated horizontal bar. The setup is shown in the diagram below.

Obtain an optical bench setup (there should be three sliding mounts on the calibrated horizontal bar. The setup is shown in the diagram below. Astronomy 100 Name(s): Exercise 4: Telescopes and spectroscopy Once the various focal issues are resolved, magnification of a small image is a significant consideration for a telescope. Though a planet

More information

Physics 30: Chapter 5 Exam Wave Nature of Light

Physics 30: Chapter 5 Exam Wave Nature of Light Physics 30: Chapter 5 Exam Wave Nature of Light Name: Date: Mark: /33 Numeric Response. Place your answers to the numeric response questions, with units, in the blanks at the side of the page. (1 mark

More information

high energy state for the electron in the atom low energy state for the electron in the atom

high energy state for the electron in the atom low energy state for the electron in the atom Atomic Spectra Objectives The objectives of this experiment are to: 1) Build and calibrate a simple spectroscope capable of measuring wavelengths of visible light. 2) Measure several wavelengths of light

More information

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016 Diffraction Gratings, Atomic Spectra Prof. Shawhan (substituting for Prof. Hall) November 14, 2016 1 Increase number of slits: 2 Visual Comparisons 3 4 8 2 Diffraction Grating Note: despite the name, this

More information

UNIVERSITY OF CALIFORNIA - SANTA CRUZ DEPARTMENT OF PHYSICS PHYS 133 PROFESSOR: SHER. Atomic Spectra. Benjamin Stahl

UNIVERSITY OF CALIFORNIA - SANTA CRUZ DEPARTMENT OF PHYSICS PHYS 133 PROFESSOR: SHER. Atomic Spectra. Benjamin Stahl UNIVERSITY OF CALIFORNIA - SANTA CRUZ DEPARTMENT OF PHYSICS PHYS 133 PROFESSOR: SHER Atomic Spectra Benjamin Stahl Lab Partners: Aaron Lopez & Dillon Teal April 2, 2014 Abstract As an introduction to spectroscopy,

More information

How to use your astronomical telescope for the first time.

How to use your astronomical telescope for the first time. How to use your astronomical telescope for the first time. A quick guide to setting up and using your telescope for the first time. There are 10 pages in this section which cover a variety of topics to

More information

A system of two lenses is achromatic when the separation between them is

A system of two lenses is achromatic when the separation between them is L e c t u r e 1 5 1 Eyepieces Single eye lens in a telescope / microscope produces spherical and chromatic aberrations. The field of view is also narrow. The eye lens is replaced by a system of lenses

More information

INTRODUCTION TO THE TELESCOPE

INTRODUCTION TO THE TELESCOPE INTRODUCTION TO THE TELESCOPE What will you learn in this Lab? For a few of the labs this semester, you will be using an 8-inch Celestron telescope to take observations. This lab will introduce you to

More information

Atomic Spectra & Electron Energy Levels

Atomic Spectra & Electron Energy Levels CHM151LL: ATOMIC SPECTRA & ELECTRON ENERGY LEVELS 1 Atomic Spectra & Electron Energy Levels OBJECTIVES: To measure the wavelength of visible light emitted by excited atoms to calculate the energy of that

More information

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado Experiment 3 1 Introduction The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado The Michelson interferometer is one example of an optical interferometer.

More information

How does your eye form an Refraction

How does your eye form an Refraction Astronomical Instruments Eyes and Cameras: Everyday Light Sensors How does your eye form an image? How do we record images? How does your eye form an image? Refraction Refraction is the bending of light

More information

Lab #13: Polarization

Lab #13: Polarization Lab #13: Polarization Introduction In this experiment we will investigate various properties associated with polarized light. We will study both its generation and application. Real world applications

More information

ARC SPECTRUM OF IRON /COPPER / BRASS

ARC SPECTRUM OF IRON /COPPER / BRASS ARC PECTRUM OF IRON /COPPER / BRA Aim : To determine the wavelength of prominent lines in the emission spectrum of iron/ copper/ brass. Apparatus : Constant deviation spectrometer, dc voltage source, metal

More information

Laboratory Manual Physics_1. Index of refraction for solids

Laboratory Manual Physics_1. Index of refraction for solids AGH University of Science and Technology in Cracow Department of Electronics Laboratory Manual Physics_ Title: 009 r. Index of refraction for solids Experiment No. 9 . Goal To determine the index of refraction

More information

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246 The Spectrophotometer and Atomic Spectra of Hydrogen Physics 46 Introduction: When heated sufficiently, most elements emit light. With a spectrometer, the emitted light can be broken down into its various

More information

Assignment 3 Due September 27, 2010

Assignment 3 Due September 27, 2010 Assignment 3 Due September 27, 2010 Text readings Stops section 5.3 Dispersing and Reflecting Prisms [sections 5.5.1 and 5.5.2] Optical systems section 5.7 Lens Aberrations [section 6.3] Be careful about

More information

Observation of Atomic Spectra

Observation of Atomic Spectra Observation of Atomic Spectra Introduction In this experiment you will observe and measure the wavelengths of different colors of light emitted by atoms. You will first observe light emitted from excited

More information

Dispersive power. of Prism

Dispersive power. of Prism Dispersive power of Pris 1 Dispersive Power of Pris Experient No. Object : To deterine the dispersive power of the aterial of a pris by spectroeter. Apparatus : Spectroeter, pris, spirit level, reading

More information

Conceptual Physics. Luis A. Anchordoqui. Department of Physics and Astronomy Lehman College, City University of New York. Lesson VI October 3, 2017

Conceptual Physics. Luis A. Anchordoqui. Department of Physics and Astronomy Lehman College, City University of New York. Lesson VI October 3, 2017 Conceptual Physics Luis A. Anchordoqui Department of Physics and Astronomy Lehman College, City University of New York Lesson VI October 3, 2017 https://arxiv.org/abs/1711.07445 L. A. Anchordoqui (CUNY)

More information

EXPERIMENT NO. 8. OBJECT: To determine the wavelength of sodium light by method.

EXPERIMENT NO. 8. OBJECT: To determine the wavelength of sodium light by method. EXPERIMENT NO. 8 OBJECT: To determine the wavelength of sodium light by method. Fresnel s APPARATUS: Optical bench with four uprights, a sodium lamp, Fresnel s, a convex lens and micrometer eyepiece. DIAGRAM:

More information

Chapter 35 Diffraction and Polarization. Copyright 2009 Pearson Education, Inc.

Chapter 35 Diffraction and Polarization. Copyright 2009 Pearson Education, Inc. Chapter 35 Diffraction and Polarization 35-1 Diffraction by a Single Slit or Disk If light is a wave, it will diffract around a single slit or obstacle. 35-1 Diffraction by a Single Slit or Disk The resulting

More information