Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

Size: px
Start display at page:

Download "Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061"

Transcription

1 ETC Laboratories ETC Laboratories Corporate Offices / Laboratories 297 Buell Road Rochester, NY (585) Fax: (585) Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX Productline Series/Model Series 5400 Vinyl Patio Door Report Number ETC

2 Page 2 of 10 Report Number: Job Number: Simulation Date: Report Date: Expiration Date: Revision Date: ETC ETC July 26, 2007 July 26, 2007 July 26, 2011 February 19, 2008 NFRC , , Simulation Report Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX Product Series/Model Series 5400 Vinyl Patio Door Operating Type Sliding Patio Door with Frame, XO Model Size (mm x mm) 2000 x 2000 Validation Test Unit Description* Item Unit Value Frame type - VY Sash type - VA Overall width in Overall height in Overall IG nominal thickness Number of glazing layers - 2 Glass type Float Glass 1 thickness in Glass 2 thickness in Glass 3 thickness in. - Spacer type - A8-D Gap 1 thickness in Gap 2 thickness in. - Low-e emissivity Low-e surface - 2 IG gap fill - ARG Percent gap fill - 90 * Aluminum reinforcements in all members of both panels Simulated U-Factor Notes: Validation Test Unit U-factor Item Unit Value Btu/hr-ft 2 - o F The validation unit was submitted by Showcase Custom Vinyl Windows. 0.36

3 Page 3 of 10 NFRC (U-factor), (SHGC and VT), and (CR-value) Productline Matrix Manufacturer Name: Showcase Custom Vinyl Windows Job Number: ETC Product Series / Model: Series 5400 Vinyl Patio Door Sim Lab Code: SETC Operator Type: Sliding Patio Door with Frame, XO Model Size (mm x mm) 2000 x 2000 Frame Type: VY Thermal Break Type: Sash Type: VA Report Number: ETC Product Number Grouping ID Number Overall IG Thickness Pane Thickness #[1] Pane Thickness #[2] Pane Thickness #[3] Gap 1 Gap 2 Gap Fill 1 Gap Fill 2 Spacer Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 Tint C-O-G U-factor C-O-G SHGC C-O-G VT Grid Type Grid Size Total Product U-factor CR - Value Total Product SHGC Total Product VT Additional Comments AIR A8-D N RLE/Clr AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N RLE/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' AIR A8-D N RLE/Clr AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N RLE/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' AIR A8-D N RLE/030-Lami AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N RLE/060-Lami AIR A8-D G < 1''

4 Page 4 of 10 Report Number: ETC Product Number Grouping ID Number Overall IG Thickness Pane Thickness #[1] Pane Thickness #[2] Pane Thickness #[3] Gap 1 Gap 2 Gap Fill 1 Gap Fill 2 Spacer Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 Tint C-O-G U-factor C-O-G SHGC C-O-G VT Grid Type Grid Size Total Product U-factor CR - Value Total Product SHGC Total Product VT Additional Comments AIR A8-D S >1'' AIR A8-D N RLE/090-Lami AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N RLE/030-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N RLE/060-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N RLE/090-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' AIR A8-D N EE272/Clr AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE366/Clr AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N EE272/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1''

5 Page 5 of 10 Report Number: ETC Product Number Grouping ID Number Overall IG Thickness Pane Thickness #[1] Pane Thickness #[2] Pane Thickness #[3] Gap 1 Gap 2 Gap Fill 1 Gap Fill 2 Spacer Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 Tint C-O-G U-factor C-O-G SHGC C-O-G VT Grid Type Grid Size Total Product U-factor CR - Value Total Product SHGC Total Product VT Additional Comments ARG 90 A8-D N EE366/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' AIR A8-D N EE272/Clr AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE366/Clr AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N EE272/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE366/Clr, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' AIR A8-D N EE272/030-Lami AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE272/060-Lami AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE272/090-Lami AIR A8-D G < 1''

6 Page 6 of 10 Report Number: ETC Product Number Grouping ID Number Overall IG Thickness Pane Thickness #[1] Pane Thickness #[2] Pane Thickness #[3] Gap 1 Gap 2 Gap Fill 1 Gap Fill 2 Spacer Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 Tint C-O-G U-factor C-O-G SHGC C-O-G VT Grid Type Grid Size Total Product U-factor CR - Value Total Product SHGC Total Product VT Additional Comments AIR A8-D S >1'' AIR A8-D N EE366/030-Lami AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE366/060-Lami AIR A8-D G < 1'' AIR A8-D S >1'' AIR A8-D N EE366/090-Lami AIR A8-D G < 1'' AIR A8-D S >1'' ARG 90 A8-D N EE272/030-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE272/060-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE272/090-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE366/030-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE366/060-Lami, Arg

7 Page 7 of 10 Report Number: ETC Product Number Grouping ID Number Overall IG Thickness Pane Thickness #[1] Pane Thickness #[2] Pane Thickness #[3] Gap 1 Gap 2 Gap Fill 1 Gap Fill 2 Spacer Emissivity Surface 1 Emissivity Surface 2 Emissivity Surface 3 Emissivity Surface 4 Emissivity Surface 5 Emissivity Surface 6 Tint C-O-G U-factor C-O-G SHGC C-O-G VT Grid Type Grid Size Total Product U-factor CR - Value Total Product SHGC Total Product VT Additional Comments ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' ARG 90 A8-D N EE366/090-Lami, Arg ARG 90 A8-D G < 1'' ARG 90 A8-D S >1'' Comments : Patio Door with vinyl frame and sashes. Aluminum reinforcements in all members of panel except the lock stile. Steel reinforcement in lock stile. ARG - Argon with Single Probe filling method. A8-D - Exposed corregated aluminum spacer with butyl - dual sealed. N - Products with no internal grids. G (Grid Size: <1") - Products with 0.188" x 0.802" size internal grids. S - Products with 1.121" size simulated divided lites. Low-e: Acclimate RLE 70/36 (Guardian); LoE²-272 (Cardinal IG); LoE³-366 (Cardinal IG) Lami: 0.266" laminate - [3mm " Solutia PVB - 3mm]; 0.315" laminate - [3mm " Solutia PVB - 3mm]; 0.315" laminate - [3mm " Solutia PVB - 3mm] Revision History: ETC Options were added. U-factor: Thermal Transmittance through the specimen SHGC: Solar Heat Gain Coefficient VT: Visible Transmittance CR: Condensation Resistance

8 Page 8 of 10 Specialty Products Series 5400 Vinyl Patio Door Report Number: ETC No Dividers Divider <1" Divider >1" SHGC SHGC VT VT SHGC = SHGC 0 + SHGC c * (SHGC 1 - SHGC 0 ) VT = VT 0 + VT c * (VT 1 - VT 0 ) Where SHGC c = Center of Glass Solar Heat Gain Coefficient & VT c = Center of Glass Visible transmittance Modeling Assumptions Patio door with aluminum reinforcements in meeting stiles (Group Leader) are grouped with the patio door with steel reinforcements in meeting stiles. Grouping Performed: 1) Center-of-Glazing

9 Page 9 of 10 Product Description Series 5400 Vinyl Patio Door Report Number: ETC Frame: Size (mm) Material Glazing Method Glazing Sealant Sash (1): Operation Type Material Glazing Method Glazing Sealant Sash (2): Operation Type Material Glazing Method Glazing Sealant 2000 x 2000 Vinyl - Rigid Exterior Glazed Silicone Horizontal Sliding Vinyl - Rigid Exterior Glazed Silicone Reinforcement Material & Locations: Aluminum reinforcements in all members of panel except the lock stile. Steel reinforcement in lock stile. Weatherstripping Type and Locations: Fin pile weatherstripping in all members of panel. Others: ARG - Argon with Single Probe filling method. A8-D - Exposed corregated aluminum spacer with butyl - dual sealed. Low-e: Acclimate RLE 70/36 (Guardian); LoE²-272 (Cardinal IG); LoE³-366 (Cardinal IG) This report, in its original form contains product drawings and a Bill of Materials.

10 Page 10 of 10 Report Number: ETC Conditions, Terms, and General Notes Regarding The Simulation The individual products were simulated in full accordance with NFRC , & , using NFRC approved programs Window 5.2 and THERM 5.2. All window specifications were received from drawings and bill of materials supplied by the manufacturer. This report may not be reproduced except in full, without the approval of ETC Laboratories. This report relates only to the items simulated. Rounding is per NFRC unit conversion and rounding Policy. The rating values included in this report are for submittal to an NFRC-licensed IA and not meant to be used directly for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labeling purposes. ETC Laboratories makes no opinions or endorsements regarding this product and its performance. ETC Laboratories letters, reports, its name or insignia or mark are for the exclusive use of the client so named herein and any other use is strictly prohibited. The report, letters and the name of ETC Laboratories, its seal or mark shall not be used in any circumstance to the public or in any advertising. Limitation of Liability: Due diligence was used in rendering the professional opinion. By acceptance of this report, the client agrees to hold harmless and indemnify ETC Laboratories, Inc. from and against all liability, claims, and demands of any kind whatsoever, which arise out of or in any manner connected with the performance of the work referred to herein. FOR ETC LABORATORIES Michael Cooper Simulation Technician, NFRC Certified Simulator Thermal Simulation Department Gurjinder Singh Simulator-in-Responsible Charge, NFRC Certified Simulator Thermal Simulation Department

11 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

12 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

13 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

14 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

15 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

16 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

17 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

18 ETC Laboratories Report #: Verified By: GS Date: ETC /26/2007

SIMULATION TEST REPORT NCTL E0A0

SIMULATION TEST REPORT NCTL E0A0 SIMULATION TEST REPORT NCTL-610-21539-1E0A0 REPORT TO: All Seasons Window & Door System Inc. 1340 Metropolitan Avenue Brooklyn, NY 11237 SIMULATION DATE: 11/20/18 PRODUCT: EU400 Tilt & Turn This report

More information

WINDOW SIMULATION REPORT

WINDOW SIMULATION REPORT WINDOW SIMULATION REPORT NFRC 100: Procedure for Determining Fenestration Product U-Factors NFRC 200: Solar Heat Gain Coefficient and Visible Transmittance NFRC 500: Procedure for Determining Fenestration

More information

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15 MGM INDUSTRIES, INC. Report No: NCTL-110-14571-1 NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15 Test Specimen NFRC Code Manufacturer: MGM Industries, Inc. Series/Model: Series 4600 Window Type:

More information

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ): NORTH EAST WINDOWS USA, INC. NFRC THERMAL TEST SUMMARY REPORT Report No: NCTL-110-17842-3S Test Specimen NFRC Code Manufacturer: North East Windows USA, Inc. Series/Model: Series CW 300 Window Type: Casement-

More information

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen MGM INDUSTRIES, INC. Report No: NCTL-110-13834-1S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15 Test Specimen NFRC Code Manufacturer: MGM Industries, Inc. Series/Model: 8017 Window Type: Double

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC. NFRC 102-2014 THERMAL PERFORMANCE TEST REPORT Rendered to: NORTH EAST WINDOWS USA, INC. SERIES/MODEL: 100 Double Hung TYPE: Vertical Slider (Double Hung) Summary of Results Standardized Thermal Transmittance

More information

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06 ALL SEASONS DOOR & WINDOW, INC. Report No: NCTL-110-8058-5S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06 Test Specimen NFRC Code Manufacturer : All Seasons Door & Window, Inc. Series/Model

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. NFRC 102-2014 THERMAL PERFORMANCE TEST REPORT Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: 45X - High Performance Dual Thermally Broken Storefront TYPE: Glazed Wall Systems (Site-built) Summary of

More information

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen * This is not the original copy of the test report if you would like an original copy, please contact our East Brunswick office or the NCTL to request a copy. ALL SEASONS DOOR & WINDOW, INC. REPORT NO:

More information

THERMAL PERFORMANCE TEST REPORT

THERMAL PERFORMANCE TEST REPORT THERMAL PERFORMANCE TEST REPORT Manufacture: Address: Coral Architectural Products 7704B Industrial Lane Tampa, Florida 33637 Specifications: ANSI/NFRC 102-2014: Test Procedure for Measuring the Steady-State

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed NFRC 102-201 THERMAL PERFORMANCE TEST REPORT Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed Summary of Results Standardized Thermal Transmittance (U-Factor) 0.39 Unit Size: 7" x

More information

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT SCOPE OF WORK DR65 FIXED REPORT NUMBER H3108.01-301-46 R0 TEST DATE 11/09/17 ISSUE DATE 11/14/17 RECORD RETENTION END DATE 11/09/22 PAGES

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed Architectural Testing NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: PARAMOUNT WINDOWS CORPORATION SERIES/MODEL: 4000 TYPE: Fixed Summary of Results Standardized Thermal Transmittance (U-Factor)

More information

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING NFRC 201-2004 SOLAR HEAT GAIN COEFFICIENT TEST REPORT Rendered to: CLEAR FOCUS IMAGING SERIES/MODEL: SunSecure BASE WINDOW: 3/16" Clear Single Glazed PRODUCT TYPE: Window Film on the Interior of Clear

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC. NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: CMI ARCHITECTURAL PRODUCTS, INC. SERIES/MODEL: CTS Thermal Clip Framing System TYPE: Glazed Wall Systems (Site-built) Summary of Results Standardized

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: UNITED STATES ALUMINUM SERIES/MODEL: 7400 TYPE: Fixed Summary of Results Standardized Thermal Transmittance (U-Factor) 0.37 Unit Size 47-1/4''

More information

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450) 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) 652-0838 Fax : (450) 652-7588 info@air-ins.com THERMAL PERFORMANCE VALIDATION TEST CONDUCTED ON YOUR 300 / 301 FIXED WINDOW IN ACCORDANCE

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: 375-T - High Performance Medium Stile Thermal Door (Dual Glazed) TYPE: Swinging Door with Frame Summary

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM Architectural Testing NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM SERIES/MODEL: 7600 Projected Vent TYPE: Projecting

More information

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC. Architectural Testing NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: TUBELITE, INC. SERIES/MODEL: T14000 Storefront (Standard) TYPE: Glazed Wall Systems (Site-built) Summary of Results Standardized

More information

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases Solar Radiation 230 BTU s per Hr/SF 89 83 82 90 Performance Glazing Coatings, Layers & Gases Learning Objectives After Viewing This Presentation You Will Understand: q The NFRC Labeling System q Light

More information

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab ASTM C 1363-11 THERMAL PERFORMANCE TEST REPORT Rendered to: UNIVERSAL PULTRUSIONS, LLC PRODUCT: Fiberglass Door Slab Summary of Results Thermal Transmittance (Btu/hr.ft².F), U-factor Overall Thermal Resistance

More information

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer Page 1 of 11 Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM Project/Customer: Profilex HM spacer Content: U f simulation of profiles in accordance to EN ISO 10077-2

More information

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values National Fenestration Rating Council Incorporated NFRC 500-2010 [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values 2010 NATIONAL FENESTRATION RATING COUNCIL, INC. PREPARED

More information

Winter Night. Thermos 6mm Outdoors # #

Winter Night. Thermos 6mm Outdoors # # February 26, 2016 By Gagnon, Stephan stephan@thermosrn.ca Thermos 3mm à 6mm vs Climaguard 80/70 Make-up Name Make-up Icon Transmittance Reflectance U-Value Visible (τ v %) (τ e %) Visible ρ v % out ρ v

More information

CAE 463/524 Building Enclosure Design Fall 2012

CAE 463/524 Building Enclosure Design Fall 2012 CAE 463/524 Building Enclosure Design Fall 2012 Lecture 8: Fenestration (+ exam review) Dr. Brent Stephens, Ph.D. Department of Civil, Architectural and Environmental Engineering Illinois Institute of

More information

WITH LOW EMISSIVITY GLASS

WITH LOW EMISSIVITY GLASS COMPARATIVE TABLE WITH LOW EMISSIVITY GLASS Quebec Version 2.0 LEGEND U Value : A measure of the gain or loss of heat through the glass due to the difference between indoor and outdoor temperatures. The

More information

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

Window air permeability measurement, watertightness and resistance to wind load (designation of the test) KTU INSTITUTE OF ARCHITECTURE AND CONSTRUCTION BUILDING THERMAL PHYSICS Notified Body number: 2018 BANDYMAI ISO/IEC 17025 Nr. LA. 01.031 Test performed: Product: Page (pages) 05 of August 2013 1 (8) Window

More information

Glazing selection for solar design

Glazing selection for solar design Glazing selection for solar design Visible light transmittance: A measure of the amount of visible light that passes through the glazing material of a window, door, or skylight. Visible light transmittance,

More information

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material PERFORMANCE TEST REPORT Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material Report No: Report Date: 10/24/11 Expiration Date: 09/27/15 130 Derry Court York, PA 17406-8405

More information

NFRC Errata and Addendum Log

NFRC Errata and Addendum Log NFRC 101-2017 NFRC Errata and Addendum Log E2A7 (May 2018) Participant Product Density Conductivity Emissivity Azon Azon Eagle Window and Doors Tremco Azo-Core 13 Azo-Core 17 Eagle Window and Doors- Eagle

More information

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate PERFORMANCE TEST REPORT Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate Report No.: E3490.01-106-31 Report Date: 07/13/15 Test Record Retention Date: 06/18/19

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6986/-SA6987 Revision 0 Subject: Sound Absorption Test Date: 01 February 2017 Contents: on Sound Absorption Data, One-third Octave

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6266/-SA6274 Revision 0 Subject: Sound Absorption Test Date: 17 February 2015 Contents: on Sound Absorption Data, One-third Octave

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL07190-001A FP22-34L-40K-10V Date: 12/18/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6956 Revision 1 Subject: Sound Absorption Test Date: 04 January 2017 Contents: on Sound Absorption Data, One-third Octave bands Sound

More information

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method INTERNATIONAL STANDARD ISO 10077-1 First edition 2000-07-15 Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method Performance thermique des fenêtres,

More information

Determination of thermal transmittance of window (test title)

Determination of thermal transmittance of window (test title) INSTITUTE OF ARCHITECTURE AND CONSTRUCTION OF KAUNAS UNIVERSITY OF TECHNOLOGY SCIENCE LABORATORY OF BUILDING THERMAL PHYSICS Notified Body number: 2018 BANDYMAI ISO/IEC 17025 Nr. LA. 01.031 page (pages)

More information

Vinyl Products Pella Windows and Doors

Vinyl Products Pella Windows and Doors Vinyl Products Pella Windows and Doors 2017 PELLA PRODUCT PORTFOLIO BRAND Encompass by Pella Pella 250 Series Pella 350 Series Pella Impervia Pella 450 Series Designer Series Architect Series Contemporary

More information

Reflectec Thermal Fabric & Reflectec Fiberboard

Reflectec Thermal Fabric & Reflectec Fiberboard MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) TEST REPORT Reflectec Thermal Fabric & Reflectec Fiberboard Project No. 16723-113972 April 22, 2003 Prepared for: John W. Mallette

More information

FG 623 Window Wall. Optional Features Integrates with standard Kawneer windows

FG 623 Window Wall. Optional Features Integrates with standard Kawneer windows JNURY, 0 FTURS Features FG is an inside glazed system -/" sight line with standard " system depth Optional IsoLock TM lanced pour and debridged thermal break Screw spline and shear block fabrication and

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Evidence of Performance Thermal transmittance

Evidence of Performance Thermal transmittance Evidence of Performance Thermal transmittance Test Report 10-001988-PR02 (PB-H01-06-en-01) Client Mályi-Glass Kft. Pesti ut 7 3434 Mályi Hungary Product Insulating glass unit System designation Variants

More information

NFRC Errata and Addendum Log

NFRC Errata and Addendum Log NFRC 101-2017 NFRC Errata and Addendum Log E2A6 (March 2018) Participant Product Density Conductivity Emissivity Tremco EnerEDGE Silicone Warm- Edge Spacer, non-white 745657 0.1050.118 0.061068 0.726817-12/31/2021

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08473-001A SA21-16027MDFD-12DE26-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6712/-SA6713 Revision 0 Subject: Sound Absorption Test Date: 17 May 2016 Contents: on Sound Absorption Data, One-third Octave bands

More information

Cat# LED Linear High Bay 100W

Cat# LED Linear High Bay 100W Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08597-001A ZR24M-40L-35K-10V-FD Date: 6/21/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09633-001A LS4-50L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05591-001B CPY250AxxFB-UL40Kxxxx / BXCCAxA13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

THERMAL SIMULATION REPORT. TCL2013-Origin-01 Prepared For:

THERMAL SIMULATION REPORT. TCL2013-Origin-01 Prepared For: THERMAL SIMULATION REPORT Report Number: TCL2013-Origin-01 Prepared For: Origin Frames Ltd Unit 3 Sunters End Hillbottom Road Sands Industrial Estate High Wycombe Bucks HP12 4HS Window System Identifier:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10710-001A OSQ-HO-A-xx-5SH-50L-50K-UL Date: 05/31/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Gerry Thornton

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09259-001A OSQ-HO-A-xx-15D-40L-40K-UL Date: 09/26/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree,

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 0077-2 First edition 2003-0-0 Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 2: Numerical method for frames Performance thermique

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08367-001A SB13-02427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08368-001A SB13-03427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063 Report No.: EED35I000235-1 Page 1 of 12 Customer : Revolution Lighting Technologies Address : 4139 Guardian Street, Simi Valley, CA93063 Description of the submitted sample(s): Sample Name : LED TUBE Model/Type

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL11180-001A OSQ-HO-A-NM-3ME-65L-40K-UL-BZ Date: 08/10/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,

More information

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 REPORT NUMBER: 102550917MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA TEST REPORT EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Cali Bamboo 6675 Mesa Ridge

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08254-001A S-DL4-A-42L-40K-W w_s-dl4t-a-ssc Date: 04/27/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09255-002A OSQ-HO-A-xx-3ME-40L-40K-UL w/osq-ho-blsf Date: 09/09/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1 Designation: 97 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method for Measuring

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04023-001 CXBAxxM40K8 CXBA16N Date: 7/27/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09234-001A ZR24M-50L-40K-10V-FD Date: 9/8/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE: REPORT NUMBER: 131119020GZU-001 ORIGINAL ISSUE DATE: 2013-12-12 EVALUATION CENTER TEST REPORT Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Block E, No.7-2 Guang Dong Software Science Park,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Laboratory ID. Laboratory Name. Address. Phone. Lab Manager/Supervisor. QA Officer. Analyst(s) Auditor. Date(s) of Audit

Laboratory ID. Laboratory Name. Address. Phone. Lab Manager/Supervisor. QA Officer. Analyst(s) Auditor. Date(s) of Audit Method(s): Laboratory ID Laboratory Name Address Phone Lab Manager/Supervisor QA Officer Analyst(s) Auditor Date(s) of Audit NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION OFFICE OF QUALITY ASSURANCE

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09245-001A SPAR38-1503025TD-12DE26-1 Date: 9/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06803-001A BPAR30S-0803040C-12DE26-1C100 Date: 9/26/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania 2014-06-26 REPORT U D -Analysis of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT-03163 Lithuania I G P a s s i v h u s S v e IG Passivhus Sverige Tel: 0470-705175

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL06982-001A BPAR30L-0803025C-12DE26-1C100 Date: 10/6/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information