IES LM MEASUREMENT AND TEST REPORT For

Size: px
Start display at page:

Download "IES LM MEASUREMENT AND TEST REPORT For"

Transcription

1 IES LM MEASUREMENT AND TEST REPORT For Suzhou RUNLUX Electric Ltd. Kunshan Economic&Technological Development Zone, Kunshan City, Jiangsu, P.R.China. Test Model: R1-22TLD30W35K Report Type: Test Engineer: Electrical and Photometric tests including: Luminous Flux, Chromaticity, Luminous Intensity Distribution, THD, Power Factor Daniel Duan Report Number: R1KS Test Date: to Report Date: Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: Fax: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

2 1. Product Description General Information: One sample was received on and used for testing. Model Tested: Manufacturer: Brand Name: Product Designation: Dimmable: Dimming Range: Burning Time Before Test: R1-22TLD30W35K Suzhou RUNLUX Electric Ltd. RUNLUX 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Continuous Dimming 10% to 100% 0hour(For New Products) Rated Values: Rated Voltage/Frequency: Rated Power: Nominal CCT: Nominal Lumen Output: VAC, 50/60Hz 30W Nominal CRI: Standards Used 3500K 3650 Im IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C : Harmonic Emission Limits Related Power Quality Requirements for Lighting IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in NVLAP accreditation scope) 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Calibration date Calibration due date 2.0m integrating sphere EVERFINE R R High accuracy array spectroradiometer EVERFINE HAAS T nm Digital Power Meter EVERFINE PF2010A V/20A Digital CC&CV DC Power Supply EVERFINE WY305- V V/5A Temperature/humidity/clock Victor VC230 EE023 0~40 C0~90% Standard Light Source SENSING N/A LSD N/A Special zero-voltage synchronous switching AC AC Power Supply T 30V/5A V, 0-300V DC Power Supply EVERFINE WY V/5A Power Meter YOKOGAWA WT KB /30/60/150/300/600V Goniophotometer EVERFINE EVERFINE DPS1010- YF VPS1030 EVERFINE PWM GO- R5000 YG108492N mm,3000W/10A Wireless Remote Sensor N/A 433MHz N/A 0 C~50 C;-20 C~60 C Report No. R1KS Page 2 of 17 The NVLAP Lab Code is

3 Device Manufacture Model No Serial No Test Range Calibration date Calibration due date Standard Light Source EVERFINE D N/A Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). 4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=1.8% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=20K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.8(K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree. The uncertainty of the luminous intensity is U=1.6% (K=2), at the 95% confidence level. Additional Test The Additional Test item may not be covered by IESNA LM Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25 C±1 C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Fidelity Index and Gamut Index Calculation The R f, R g was calculated according to IES TM by using calculation tools. The calculation was based on the measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only. Report No. R1KS Page 3 of 17 The NVLAP Lab Code is

4 5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 0.5 hour Test orientation: Downward Photometric and Electrical Measurement Result Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm) Efficacy (lm/w) Radiant Flux (W) CCT (K) Duv x y u' v' Color Rendering Index Ra 83.9 R1 R2 R3 R R5 R6 R7 R R9 R10 R11 R R13 R14 R Report No. R1KS Page 4 of 17 The NVLAP Lab Code is

5 Fidelity Index and Gamut Index Fidelity Index R f 83 Gamut Index R g Spectral Power Distribution Comparison Test source Reference source SPD (normalized to Y=100) λ (nm) 140 Plot of R g versus R f R g R f Report No. R1KS Page 5 of 17 The NVLAP Lab Code is

6 Chroma Shift by Hue R f by Hue 20% % 10% % 80 0% -5% % 60-15% -20% Hue Bin Hue Bin Color Vector Graphic Refenerce Illuminat Test Source Report No. R1KS Page 6 of 17 The NVLAP Lab Code is

7 Color Evaluation Sample CES01 CES03 CES05 CES07 CES09 CES11 CES13 CES15 CES17 CES19 CES21 CES23 CES25 CES27 CES29 CES31 CES33 CES35 CES37 CES39 CES41 CES43 CES45 CES47 CES49 CES51 CES53 CES55 CES57 CES59 CES61 CES63 CES65 CES67 CES69 CES71 CES73 CES75 CES77 CES79 CES81 CES83 CES85 CES87 CES89 CES91 CES93 CES95 CES97 CES99 Bay Area Compliance Laboratories Corp. (Shenzhen) Color Fidelity by CES Sample Fidelity Index, R f Report No. R1KS Page 7 of 17 The NVLAP Lab Code is

8 1.0 Relative Spectral Power Distribution nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+01 Report No. R1KS Page 8 of 17 The NVLAP Lab Code is

9 nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+00 Report No. R1KS Page 9 of 17 The NVLAP Lab Code is

10 CIE 1931 x y Chromaticity Diagram Step Chromaticity Quadrangles sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Black Body Report No. R1KS Page 10 of 17 The NVLAP Lab Code is

11 [Goniophotometer System] Total operating time for luminous intensity distribution: 1.0 hour Test orientation: Downward Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) I max (cd) S/MH (C0/180) S/MH (C90/270) Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): Field Angle (10% Imax): Report No. R1KS Page 11 of 17 The NVLAP Lab Code is

12 Luminous Intensity (cd) Distribution Data γ C Bay Area Compliance Laboratories Corp. (Shenzhen) Report No. R1KS Page 12 of 17 The NVLAP Lab Code is

13 Luminous Intensity (cd) Distribution Data (cont.) γ C Report No. R1KS Page 13 of 17 The NVLAP Lab Code is

14 Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % Report No. R1KS Page 14 of 17 The NVLAP Lab Code is

15 [Additional Test] Test Item Test Voltage (V) Frequency (Hz) Test Result Power Factor: Total Harmonic Distortion: % Total Harmonic Distortion: % Total Harmonic Distortion: % Power Factor: Report No. R1KS Page 15 of 17 The NVLAP Lab Code is

16 6. Product Photo Report No. R1KS Page 16 of 17 The NVLAP Lab Code is

17 7. Product Test orientation in the Goniophotometer Bay Area Compliance Laboratories Corp. (Shenzhen) ***********END OF REPORT*********** Report No. R1KS Page 17 of 17 The NVLAP Lab Code is

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL IES LM-79-08 MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Test Model: IGTFL-1515050 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/827K-DIM-G6 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For IES LM-79-08 MEASUREMENT AND TEST REPORT For MESTER LED LIMITED 3rd F, Building A,Sunshine Industrial Park, Hezhou, Xixiang, Bao an District,Shenzhen China Test Model: PL09G2427KBQH Report Type: Electrical

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB15W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-100W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-150W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For Shenzhen Jiawei Photovoltaic Lighting Co., Ltd. No. 1,2,3,4, Xinfa Industry Zone, Central Community, Pingdi Road, Longgang District, Shenzhen City, Guangdong

More information

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM IES LM-79-08 MEASUREMENT AND TEST REPORT For Eiko Limited 23220 W. 84th Street,Shawnee, KS, USA Test Model: LEDP-13WPAR30/NFL/830-DIM Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227 ACCREDITED r..:... i.-*" IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th Street, Shawnee, KS 66227 Test Model: LED15WPAR38/FL/850-DIM-G7 Report Type: Electrical and Photometric

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71604 UPC Number 60198671604 Description LED Ultra Thin Canopy Fixture 45W Voltage: 120/208/240/277 QPL ID # P89A8PQ3 Features Intergral Cooling Fin Releases the Heat Efficiently to Maintain

More information

TEST REPORT For Company:

TEST REPORT For Company: TEST REPORT For Company: EiKO Global, LLC 23220 W. 84th Street, Shawnee, KS 66227 Model: LED17WBR40/840K-DIM-G4 Report Type: Test Engineer: Testing and Report According to ENERGY STAR Program Requirements

More information

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire TESTING Report No.:BL160912008-9A NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Applicant: Maxlite.Inc Address:

More information

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IESLM-79-08TESTREPORT For KINGLUMI CO., LTD Report Number: Product Type: R011601998L1 Track or Mono-point Directional Luminaires Date

More information

Test report of IES LM Approved Method: Electrical and Photometric

Test report of IES LM Approved Method: Electrical and Photometric NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Date of issue 2016-05-17 Version 1.0 Total pages 16 Applicant:

More information

IES LM TEST REPORT For EIKO GLOBAL, LLC

IES LM TEST REPORT For EIKO GLOBAL, LLC NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For EIKO GLOBAL, LLC Report Number: Product Type: Date of Receipt: Date of Test: Date of Report: Product

More information

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For Shenzhen sunper opto co., ltd NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For Shenzhen sunper opto co., ltd Report Number: Product Type: R011506618L Architectural Flood and Spot Luminaires

More information

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd. NVLAP LAB CODE:201045-0 TEST REPORT IES LM-79-08 For Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Report

More information

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Model: IGTDL-1500830FD-4 Report

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight Page 2 of 14 Report No.: 68.184.15.296.01 Test sample... : Type of test object... : LED Downlight LED Downlight Trade mark... : Model and/or type reference... : EF150-26W-840 Rating(s)... : 220-240V~;

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063 Report No.: EED35I000235-1 Page 1 of 12 Customer : Revolution Lighting Technologies Address : 4139 Guardian Street, Simi Valley, CA93063 Description of the submitted sample(s): Sample Name : LED TUBE Model/Type

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10142-001B FLD-EDG-SN-xx-06-E-UL-xx-700-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W LM-79-08 Test Report For MaxLite Inc. 12 York Ave West Caldwell NJ 07006, USA LED Commercial Down lights Model: RR82540W Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10604-001A CPY250-B-xx-F-A-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cat# LED Linear High Bay 100W

Cat# LED Linear High Bay 100W Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542991XX(XX:41-50) Laboratory: Leading Testing

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542961XX(XX:41-50) Laboratory: Leading Testing

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL10609-001A CPY250-B-xx-F-F-UL-xx-30K Date: 04/25/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06410-001A CPY250-A-xx-D-D-UL-40K-xxxx or BXCCAxD17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06411-001A CPY250-A-xx-F-D-UL-40K-xxxx or BXCCAxA17-Ux7xxxx Date: 07/17/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

More information

TEST REPORT : Report Reference No... : V2.0. Tested by (name + signature)... : Fair Deng.

TEST REPORT : Report Reference No... : V2.0. Tested by (name + signature)... : Fair Deng. TEST REPORT Report Reference No.... : 4323305.50 V2.0 Tested by (name + signature)... : Fair Deng. Approved by (name + signature)... : Jason Zhang.. Date of issue... Number of pages. Testing Laboratory...

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05591-001B CPY250AxxFB-UL40Kxxxx / BXCCAxA13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500089-0 Report Number: Model: RESTL-2013-0013 E-WP6L03CZ Date: 8/30/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL05642-001B CPY250AxxDB-UL40Kxxxx / BXCCAxD13-Ux7xxxx Date: 06/26/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08048-001A S-DL4-15L-27K w_s-dl4t-w-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08047-001A S-DL6-11L-40K w_s-dl6t-m-ss-c Date: 04/17/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08044-001A S-DL4-11L-27K w_s-dl4t-w-ss-c Date: 04/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: RESTL-2013-0012 E-HL6S11CSZ Date: 11/08/2013 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Joshua Krohn Cree,

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08078-001B S-DL8-75L-27K w_s-dl8t-w-ss-c Date: 05/10/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08058-001B S-DL4-34L-40K w_s-dl4t-m-ss-c Date: 05/3/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08473-001A SA21-16027MDFD-12DE26-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09300-001A ARE-EHO-3M-xx-12-E-UL-xx-1000-xxxx Date: 09/16/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09635-001A LS8-100L-35K-10V-FD Date: 11/02/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared

More information