1 GRUNDFOS DATA BOOKLET Series UPS and UPSD circulator ums 5 z

2 Contents General data Performance range Product range Single-head ums Twin-head ums 5 Tye key 5 5 Alications 6 eating systems 6 Domestic hot water systems 6 Cooling and air-conditioning systems 6 Functions Seed switch 7 Standard module 7 Pums with rotection module 7 Protection module indicator lights 8 Relay module 8 Oerating modes of twin-head ums 9 Connection Electrical connection Pums with standard module Single-head ums with rotection module Single-head um with relay module Twin-head ums with relay module Signal outut of twin-head ums Installation Terminal box ositions Construction Construction aterial secification Sectional drawing Technical data Pumed liquids 5 Temerature limits 5 Technical data 5 Curve conditions 5 Data sheet UPS - F, UPSD - F 6 UPS -6 F, UPSD -6 F 7 UPS - F, UPSD - F 8 UPS - F 5, UPSD - F 5 9 UPS - F 5 UPS -6/ F 5 UPS -6/ F UPS -6/ F 5, UPSD -6/ F 5 UPS - F 5, UPSD - F 5 UPS -8 F 5 5 UPS -85 F 5 6 UPS 5- F 8, UPSD 5- F 8 7 UPS 5-6/ F 8, UPSD 5-6/ F 8 8 UPS 5-6/ F 8, UPSD 5-6/ F 8 9 UPS 5-6/ F UPS 5- F 8, UPSD 5- F 8 UPS 5-8 F 8, UPSD 5-8 F 8 UPS 5-85 F 8 UPS 65- F, UPSD 65- F UPS 65-6/ F, UPSD 65-6/ F 5 UPS 65-6/ F, UPSD 65-6/ F 6 UPS 65-6/ F 8 7 UPS 65- F 8 8 UPS 65- F, UPSD 65- F 9 UPS 65-8 F, UPSD 65-8 F UPS F UPS 8- F 6, UPSD 8- F 6 UPS 8-6 F 6, UPSD 8-6 F 6 UPS 8- F 6, UPSD 8- F 6 UPS - F 5, UPSD - F 5 5 Accessories Accessories 6 Counter flanges 6 Protection modules 6 Relay module 6 Insulation kits 7 Base late 7 Blanking flanges 8 Further roduct documentation WebCAPS 9 WinCAPS 5

3 General data Series Performance range XX-85 XX XX XX-6 XX Q [m³/h] Q [l/s] T 86

4 General data Series Product range Single-head ums PN 6 / PN PN 6 PN PN 6 / PN bronze Pressure stage Voltage [V] Poles PN 6 bronze PN bronze x - x x -5 UPS - F UPS -6 F UPS - F UPS - F 5 UPS - F 5 * UPS -6/ F * UPS -6/ F 5 UPS -6/ F 5 UPS - F 5 UPS -8 F 5 UPS -85 F 5 UPS 5- F 8 UPS 5-6/ F 8 UPS 5-6/ F * UPS 5-6/ F 8 UPS 5- F 8 UPS 5-8 F 8 UPS 5-85 F 8 UPS 65- F UPS 65-6/ F 8 * UPS 65-6/ F UPS 65-6/ F UPS 65- F 8 * UPS 65- F UPS 65-8 F UPS F UPS 8- F 6 UPS 8-6 F 6 UPS 8- F 6 UPS - F 5

5 General data Series Twin-head ums Pressure stage Voltage [V] Poles PN 6 / PN 6 PN PN 6 /PN bronze PN 6 bronze PN bronze x - x x -5 PN UPSD - F UPSD -6 F UPSD - F UPSD - F 5 UPSD -6 F 5 UPSD - F 5 UPSD 5- F 8 UPSD 5-6/ F 8 UPSD 5-6/ F 8 UPSD 5- F 8 UPSD 5-8 F 8 UPSD 65- F UPSD 65-6/ F UPSD 65-6/ F UPSD 65- F UPSD 65-8 F UPSD 8- F 6 UPSD 8-6 F 6 UPSD 8- F 6 UPSD - F 6 Tye key Examle UPS (D) 65-6 (/) F(-) 8 Tye range Twin-head um Nominal flange diameter [mm] ax. head [dm] Number of motor oles, (stated if available both as - and -ole motor) F - Pum with flanges B - Pum with bronze housing Port-to-ort length [mm] Grundfos UPS circulator ums are rovided with the energy label, excet the bronze ums (B-version). The energy label indicates the energy-saving level of the um. The energy classification system has seven levels, i.e. from A to G. Level A is the best. The energy label can be used to comare ums of the same tye and size. The energy labelling of the ums are stated on the data sheet of the um in question. 5

6 General data Series Alications Grundfos circulator ums, tyes UPS, UPSD, are designed for circulation of liquids in heating and airconditioning systems. Pums with bronze um housings are suitable for circulation in domestic hot water systems. General examles of systems in which UPS, UPSD ums are suitable are shown below. UPS, UPSD are a comlete line of circulator ums with three seeds. The ums come both as single and twin-head ums. eating systems One- and two-ie heating systems ain ums Zone ums Boiler shunt ums Out In Pums for heating surfaces Calorifers Underfloor heating systems Solar heating systems Geothermal heating systems eat recovery systems T Domestic hot water systems Domestic hot water systems T Cooling and air-conditioning systems Two-ie air-conditioning systems ain ums Zone ums Pums for refrigeration units eat um systems Geothermal heating systems eat recovery systems T

7 Functions Series Seed switch The um offers three seeds for adjustment of um erformance to the system in question. Q Fig. Pum erformance at the three seeds The seeds of the various seed switch ositions are shown in the table below: Switch osition Seed in % of maximum seed Single-hase ums Three-hase ums arox. 6 % arox. 7 % arox. 8 % arox. 85 % % % Change to a lower seed enables reduction in energy consumtion and less noise in the system. Q Q Indicator lights and seed indication T Indicator lights on standard module The function of the indicator lights on the terminal box is as shown in the following tables. Single-hase ums Single-hase ums incororate a green indicator light only: Indicator light On Off Descrition The electricity suly has been switched on. The electricity suly has been switched off. Three-hase ums Three-hase ums incororate a green and a red indicator light: Indicator lights Green Red Descrition Off Off The electricity suly has been switched off. On Off The electricity suly has been switched on. On On The electricity suly has been switched on. The direction of rotation is wrong. Pums with rotection module T Fig. Indicator lights on terminal box Standard module The module is standard in single-head ums and is also available for twin-head ums. Connect the um to the mains via an external contactor. Connect the contactor to the um s built-in thermal overload switch to rotect the um against overload at all three seeds. Standard module Fig. Protection module Protection module The rotection module is sulied as an accessory for single-head and twin-head ums. When equied with a rotection module, the um can be connected to an external switch directly, as the builtin rotection against overheating rotects the um at all three seeds. Furthermore, the module has two indicator lights. T Seed switch T 97 6 Fig. Standard module 7

8 Functions Series Protection module indicator lights The function of the indicator lights is shown in the table below. Indicator lights Green Red Note: Pums with rotection module must not be connected to a frequency converter. Relay module Descrition Off Off The um has been stoed. The electricity suly has been switched off, thermally cut out or a hase is failing. On Off The um is oerating. On Off On On Three-hase ums only: The um is oerating, but the direction of rotation is not correct. The um has been cut out by the thermal switch. The relay module is standard in twin-head ums and an otional extra for single-head ums. The module enables direct connection of the um to an external mains switch and an external oerating or fault indication device. The signal outut for an external signal device can be set to activation during oeration or fault by means of the selector switch. As standard, the signal oututs of relay modules in twin-head ums are interconnected so that the ums are oerating alternately as duty um and standby um. The um is connected directly to the mains as the um incororates overload rotection at all three seeds. If the um has been cut out by the thermal overload switch, it will restart automatically when it has cooled to normal temerature, rovided the external on/ off contact is closed. Signal outut of relay module The relay module is equied with a signal outut for external oerating or fault indication. By means of the selector switch, the outut can be used as: Oeration signal outut between terminals and or Fault signal outut between terminals and. Functions of indicator ligths and signal outut Indicator lights Signal outut Green Red Oeration Fault Off Permanently on Permanently on Off Flashes Flashes Off Off Permanently on Permanently on Off Permanently on NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C Descrition The um has been stoed. The electricity suly has been switched off or a hase is failing. The um is running. Only three-hase ums: The um is running, but with wrong direction of rotation. The um has been cut out by the thermal overload switch. The um has been stoed by an external on/off switch. The um is or has been cut out by the thermal overload switch and it has been stoed by an external on/off switch. Note: Pums with relay module must not be connected to a frequency converter. Relay module Selector switch for signal outut Seed switch T Fig. 5 Relay module Indicator lights on relay module The indicator lights on ums with relay module have more detailed oerating and fault indications. All ums with relay module are equied with a green and a red indicator light. Their functions are as shown in the table below. 8

9 Functions Series Oerating modes of twin-head ums Twin-head ums have a relay module in both terminal boxes, which are interconnected by a -core cable. P P T 9 Fig. 6 Twin-head um In addition to the signal functions, the signal outut of the relay module for twin-head ums can be used for controlling the oerating mode of um and. It is ossible to choose between three oerating modes:. Alternating oeration (factory setting). The ums oerate alternately as duty and standby um, resectively. Changeover takes lace every hours. If the duty um is cut out due to a fault, the standby um will automatically start. During changeover both ums will be running for a short eriod to ensure a low-noise changeover.. Standby oeration. The ums oerate continuously as duty and standby um, resectively. If the duty um is cut out due to a fault, the standby um will automatically start at a signal from the outut of the duty um. The sequence can be changed to make the standby um oerate as duty um.. Single-um oeration. The ums run indeendently without communicating with each other. 9

10 Connection Series Suly voltage and frequency: otor rotection: x - V, 5 z x V, 5 z x -5 V, 5 z. The um requires no external motor rotection if the motor is fitted with a rotection module. Back-u fuse: ax. A. Enclosure class: IP. Insulation class:. Screwed cable entries: x for mains connection. x for signal outut (blanked-off if um with standard module). x 6 for caacitor connection (only single-hase ums). EC (electromagnetic EN comatibility): EN Thermal overload switch Voltage Current 5 V AC cos hi =.:.5 A cos hi =.6:.6 A Start/sto inut (relay module) External otential-free contact. aximum load: 5 V,.5 ma. inimum load: V,.5 ma. Electrical connection The electrical connection and rotection should be carried out in accordance with local regulations. Earthing or neutralization can be used for rotection against indirect contact. A current- or voltage-oerated earth-leakage circuit breaker can be used as extra rotection. Never make any connections in the um terminal box unless the electricity suly has been switched off. The um must be earthed and connected to an external mains switch. The oerating voltage and frequency are marked on the um namelate. ake sure that the motor is suitable for the electricity suly on which it will be used. Pums with standard module The um must be connected to the mains via an external contactor. The contactor is to be connected to the um s built-in thermal overload switch at terminals T and T to rotect the um against overheating at all three seeds. Note: If the um is also rotected by means of a motor starter, the starter must be set to the current consumtion of the um at the chosen seed. The motor starter setting must be changed every time the um seed is changed. The current consumtion at the various seeds is stated on the um namelate. External imulse switches Oerating/fault signal outut (relay module) Internal otential-free changeover contact. aximum load: 5 V, A, AC. inimum load: 5 V, ma, DC. Single-hase T T N L Sto K K Start K N L Three-hase without neutral Three-hase with neutral T T L L L T T L L L K Sto K Sto K Start K L L L Start K K N L L L T 97 5 Fig. 7 External imulse switches

11 Connection Series External changeover switch Single-hase T T N L K Sto/Start K Single-head um with relay module The um can be connected directly to the mains as it incororates rotection against overheating at all three seeds. The relay module has a signal outut for an external oerating or fault signal device. By means of the selector switch the signal outut can be used as oeration or fault signal outut: Oeration N L Three-hase without neutral Three-hase with neutral Fault Note: The selector switch must not have been set to alternating oeration (used in connection with twin-head ums). K T T L L L K T T L L L K Oerating indication Sto/Start L L L Sto/Start K N L L L T 97 5 Fig. 8 External changeover switch Single-head ums with rotection module The um can be connected directly to the mains as the um features built-in rotection against overheating at all three seeds. The figure below shows the electrical connection of single-hase and three-hase ums. NC NO C NC NO C 7 8 N L 7 8 L L L N L N L N L L L L Fig. Oerating indication Fault indication T 97 5 N L L L L NC NO C NC NO C N L L L L T N L N L N L N L 7 8 L L L L L L T Fig. 9 Electrical connections, rotection module Fig. Fault indication

12 Connection Series Twin-head ums with relay module The ums are interconnected by a -core cable and factory-set to oerating alternately as duty and standby um. Changeover takes lace every hours. The following figures shows the electrical connections and the selector switch setting for the various oerating modes. Alternating oeration (factory setting) P NC NO C 7 8 N L N L NC NO C P 7 8 N N L L P P P P NC NO C NC NO C 7 8 N L N L 7 8 N L N L NC NO C 7 8 L L L L L L NC NO C 7 8 L L L L L L T P NC NO C NC NO C 7 8 L L L L L L Fig. Alternating oeration P 7 8 L L L L L L T Fig. Standby oeration Standby oeration with um as duty um and um as standby um. Note: In this oerating mode the selector switch of um must not have been set to alternating oeration. P P Standby oeration Standby oeration with um as duty um and um as standby um. Note: In this oerating mode the selector switch of um must not have been set to alternating oeration. NC NO C 7 8 N L N L NC NO C 7 8 N N L L P P NC NO C 7 8 L L L L L L NC NO C 7 8 L L L L L L T Fig. Standby oeration In the case of single-um oeration the cable between the ums is to be removed. The ums must be set individually and connected searately to mains, see age "Single-head um with relay module".

13 Connection Series Signal outut of twin-head ums The signal outut of twin-head ums can be used directly, rovided it is not already being used for communication between the ums. If an outut that is used for communication between the ums is to be used as signal outut, an intermediate relay is required. See examle below. The examle shows a single-hase um in alternating oeration with external fault indication in case of fault on um or both ums. P P Terminal box ositions Single-head ums Fig. 7 Permissible terminal box ositions Twin-head ums T 98 NC NO C NC NO C 7 8 N L 7 8 N L N L N L L N L N T Fig. 5 Alternating oeration with external fault indication Installation The um must be installed with horizontal motor shaft. Fig. 8 Permissible terminal box ositions and flow direction of twin-head ums For standard terminal box ositions, see technical data from age 5. T 99 Flow direction T Fig. 6 Flow direction Note: Twin-head ums in vertical ies with downward liquid flow or in horizontal ies must always run at maximum seed. Twin-head um mounted in horizontal ies must be fitted with an automatic air vent in the uer art of the um housing.

14 Construction Series Construction The UPS, UPSD ums are of the canned rotor tye, i.e. um and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the umed liquid. Attention has been focused on using as few materials as ossible, and the use of materials that might cause roblems in connection with disosal have been omitted. The um offers these features: Three-seed motor Ceramic radial bearings Carbon thrust bearing Stainless-steel rotor can, bearing late and rotor cladding Aluminium-alloy stator housing Cast iron or bronze um housing Stator with built-in thermal overload switch. aterial secification Pos. Descrition aterial DIN W.-Nr. Terminal box Comosite PA66 Insection screw Brass with nickel Namelate Comosite PA66 Stator housing Aluminium AlSi Cu Stator windings Coer wire Stator winding ca Comosite PETP 5 Cheese-head screw Steel O-rings EPD rubber 7 Outer bearing ring Aluminium oxide/sic Rotor can Stainless steel. Shaft (cast iron ums) Shaft (bronze ums) Stainless steel Stainless steel.5. 8 Rotor cladding Stainless steel. 9 Thrust bearing Carbon Y 6 Bearing late Stainless steel. Inner bearing ring Aluminium oxide/sic Sto ring Stainless steel.5 Slit cone Stainless steel.5 Imeller Stainless steel. Nut Stainless steel.5 5 Neck ring Stainless steel / PTFE. Cast iron EN-GJL-5 EN-JL- 6 Pum housing Bronze CuSn, DIN Anti-friction ring Brass/Stainless steel Non-return fla (Twin-head ums) EPD rubber 8 Slash rotection Stainless steel.5 Sectional drawing T 97 Fig. 9 Sectional drawing

15 Technical data Series Pumed liquids Thin, clean, non-aggressive and non-exlosive liquids, not containing any solid articles, fibres or mineral oil. In domestic hot water systems, it is advisable to use bronze ums only for water with a degree of hardness lower than arox. d. For water with a higher degree of hardness, use a close-couled um tye TP. If the um is installed in a heating system, the water should meet the requirements of acceted standards on water quality in heating systems, e.g. the German standard VDI 5. The ums must not be used for the transfer of inflammable liquids such as diesel oil and etrol. Temerature limits Ambient temerature: C to C Liquid temerature - for short eriods: + C - continuously: C to + C - domestic hot water: U to +6 C Storage temerature: C to +55 C. Deending on the cast-iron version and the um alication, the maximum liquid temerature may be limited by local regulations and laws. Technical data Relative humidity: ax. 95 %. Sound-ressure level: The sound-ressure level of the um is lower than db(a) (reference: mpa). Test ressure: PN 6: bar ~. Pa PN : 5 bar ~.5 Pa PN 6/: 5 bar ~.5 Pa. Test liquid: + C water containing corrosion inhibitor. Inlet ressure To avoid cavitation noise, the following minimum ressures are required at the um suction flange: * Only available as single-head um (UPS) Liquid temerature 75 C 9 C C UPS, UPSD [bar] [bar] [bar] - F F F F F 5* / F / F * / F F F F F / F / F / F * F F F F / / F 8* / F 8* F F F F 6, F F F Curve conditions The guidelines below aly to the erformance curves in the following data sheets:. Due to the danger of overheating the ums must not be used at a flow below. x Q at best efficiency oint.. The bold arts of the curves show the recommended erformance range.. Test liquid: Airless water.. The curves aly to a liquid temerature of C. 5. All curves show average values and should not be used as guarantee curves. If a stated minimum erformance is required, individual measurements must be made. 6. The conversion between head and ressure has been made for water with a density of ρ = kg/m. For liquids with other densities, e.g. hot water, the discharge ressure is roortional with the density. 7. Power curves, efficiency curves and electrical data for twin-head ums aly to single-um oeration. 5

16 UPS - F, UPSD - F Series, 5 z UPS - F, UPSD - F Inlet ressure. t m [ C] 75 9 min [bar] P 6 8 Q [m³/h] q [l/s] x V x -5 V Series is also available for x - V. Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed Q [m³/h] TA x V x -5 V UPS - F D E UPSD - F D E B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F 6/ / / UPSD - F 6/ / /9.6.. * of bronze versions are arox. % higher. 6

17 UPS -6 F, UPSD -6 F Series, 5 z UPS -6 F, UPSD -6 F Inlet ressure 5 5 P Q [m³/h] q [l/s] 6 8 Q [m³/h] TA 9 97 t m [ C] 75 9 min [bar].5..5 x V x -5 V Series is also available for x - V. Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed 7..8 Seed Seed x V x -5 V UPS -6 F C C UPSD -6 F C C B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -6 F 6/ / / UPSD -6 F 6/ / /9.6.. * of bronze versions are arox. % higher. 7

18 UPS - F, UPSD - F Series, 5 z UPS - F, UPSD - F Inlet ressure P Q [m³/h] q [l/s] 6 8 Q [m³/h] TA 9 97 t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V. Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed 5..8 Seed Seed x V x -5 V UPS - F C C UPSD - F D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F 6/ / / UPSD - F 6/ / / * of bronze versions are arox. % higher. 8

19 UPS - F 5, UPSD - F 5 Series, 5 z UPS - F 5, UPSD - F P 6 8 Q [m³/h] Q [l/s] Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed.9.9 Seed Seed Seed Q [m³/h] TA x V x -5 V UPS - F 5 C C UPSD - F 5 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F 5 6/ / 5 / UPSD - F 5 6/ / 5 /9... * of bronze versions are arox. % higher. 9

20 UPS - F 5 Series, 5 z UPS - F 5 Inlet ressure t m [ C] 75 9 min [bar] x -5 V I/ Seed Seed Seed Q [m³/h] Q [l/s] UPS - F 5 x -5 V D P Q [m³/h] TA B B D D L R / L T Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F 5 6/ / 5 /

21 UPS -6/ F 5 Series, 5 z UPS -6/ F P Q [m³/h] Q [l/s] 8 6 Q [m³/h] TA Inlet ressure t m [ C] 75 9 min [bar].5.5. x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS -6/ F 5 C C B B D D L R / B8 B9 L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -6/ F 5 6/ / 5 /9.8.. * of bronze versions are arox. % higher.

22 UPS -6/ F Series, 5 z UPS -6/ F 5 5 Inlet ressure t m [ C] 75 9 min [bar] x -5 V I/ Seed 7..8 Seed Seed P Q [m³/h] q [l/s] UPS -6/ F x -5 V C Q [m³/h] TA 9 97 B B D D L R / L T Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -6/ F 6/ / 5 /

23 UPS -6/ F 5, UPSD -6/ F 5 Series, 5 z UPS -6/ F 5, UPSD -6/ F P 8 6 Q [m³/h] Q [l/s] 5 Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed Q [m³/h] TA x V x -5 V UPS -6/ F 5 C C UPSD -6/ F 5 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -6/ F 5 6/ / 5 / UPSD -6/ F 5 6/ / 5 / * of bronze versions are arox. % higher.

24 UPS - F 5, UPSD - F 5 Series, 5 z UPS - F 5, UPSD - F 5 Inlet ressure P 8 6 Q [m³/h] Q [l/s] 8 6 Q [m³/h] TA 9 97 t m [ C] 75 9 min [bar]...7 x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS - F 5 C C UPSD - F 5 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F 5 6/ / 5 / UPSD - F 5 6/ / 5 / * of bronze versions are arox. % higher.

25 UPS -8 F 5 Series, 5 z UPS -8 F P Q [m³/h] Q [l/s] 5 Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed Q [m³/h] TA 9 97 x V x -5 V UPS -8 F 5 C C B B D D L R / B8 B9 L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -8 F 5 6/ / 5 /9..8. * of bronze versions are arox. % higher. 5

26 UPS -85 F 5 Series, 5 z UPS -85 F 5 Inlet ressure 6 6 t m [ C] 7 9 min [bar] x -5 V I/ Seed Seed Seed Series is also available for x - V P Q [m³/h] Q [l/s] x V x -5 V UPS -85 F 5 C C Q [m³/h] TA 9 99 B B D D L R / B8 B9 L T 7 6 Shi. PN [kg] vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS -85 F 5 6/ / 5 /

27 UPS 5- F 8, UPSD 5- F 8 Series, 5 z UPS 5- F 8, UPSD 5- F P Q [m³/h] Q [l/s] Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V. Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed Q [m³/h] TA x V x -5 V UPS 5- F 8 C C UPSD 5- F 8 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS 5- F 8 6/ /5 65 /9.7.. UPSD 5- F 8 6/ /5 65 / * of bronze versions are arox. % higher. 7

28 UPS 5-6/ F 8, UPSD 5-6/ F 8 Series, 5 z UPS 5-6/ F 8, UPSD 5-6/ F P Q [m³/h] Q [l/s] Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed.75.8 Seed Seed.6.67 Seed..8 Seed Seed Q [m³/h] TA x V x -5 V UPS 5-6/ F 8 C C UPSD 5-6/ F 8 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 5-6/ F 8 6/ / 65 / UPSD 5-6/ F 8 6/ / 65 / Shi. vol. [m ] 8

29 UPS 5-6/ F 8, UPSD 5-6/ F 8 Series, 5 z UPS 5-6/ F 8, UPSD 5-6/ F 8 Inlet ressure 6 6 t m [ C] 75 9 min [bar] Q [m³/h] x V x -5 V Series is also available for x - V I/ Seed Seed Seed Seed Seed Seed P Q [l/s] 8 6 Q [m³/h] TA Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 5-6/ F 8 C C UPSD 5-6/ F 8 D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 5-6/ F 8 6/ / 65 / UPSD 5-6/ F 8 6/ / 65 / Shi. vol. [m ] 9

30 UPS 5-6/ F Series, 5 z UPS 5-6/ F Inlet ressure 5 5 t m [ C] 75 9 min [bar] x -5 V I/ Seed Seed Seed Q [m³/h] Q [l/s] UPS 5-6/ F x -5 V C P Q [m³/h] TA B B D D L R / L T PN [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 5-6/ F 6/ / 65 / Shi. vol. [m ]

31 UPS 5- F 8, UPSD 8 F 8 Series, 5 z UPS 5- F 8, UPSD 5- F 8 Inlet ressure t m [ C] 75 9 min [bar] Q [m³/h] x V x -5 V I/ Series is also available for x - V. Seed Seed Seed Seed Seed Seed P Q [l/s] Q [m³/h] 5 5 TA Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 5- F 8 C C UPSD 5- F 8 C C B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B6 B8 B9 D D Net Gross UPS 5- F 8 6/ / 65 / UPSD 5- F 8 6/ / 65 / Shi. vol. [m ]

32 UPS 5-8 F 8, UPSD 8 F 8 Series, 5 z UPS 5-8 F 8, UPSD 5-8 F 8 Inlet ressure Q [m³/h] t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V I/ Seed Seed Seed Seed Seed Seed 5..7 P Q [l/s] Q [m³/h] TA 9 97 Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 5-8 F 8 C C UPSD 5-8 F 8 C C B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B6 B8 B9 D D Net Gross UPS 5-8 F 8 6/ / 65 / UPSD 5-8 F 8 6/ / 65 / Shi. vol. [m ]

33 UPS 5-85 F 8 Series, 5 z UPS 5-85 F 8 Inlet ressure 6 6 t m [ C] 75 9 min [bar] x -5 V I/ Seed Seed Seed Series is also available for x - V P Q [m³/h] Q [l/s] UPS 5-85 F 8 x -5 V D Q [m³/h] TA 9 99 B B D D L R / B8 B9 L T 7 6 Shi. PN [kg] vol. L L L B B B B6 B6 B8 B9 D D Net Gross [m ] UPS 5-85 F 8 6/ /5 65 /

34 UPS 65- F, UPSD 65- F Series, 5 z UPS 65- F, UPSD 65- F Inlet ressure.8 t m [ C] 75 9 min [bar] Q [m³/h] x V x -5 V Series is also available for x - V I/ Seed Seed Seed Seed Seed Seed P Q [l/s] Q [m³/h] TA 9 97 Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 65- F C C UPSD 65- F D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65- F 6/ / 85 / UPSD 65- F 6/ / 85 / Shi. vol. [m ]

35 UPS 65-6/ F, UPSD 65-6/ F Series, 5 z UPS 65-6/ F, UPSD 65-6/ F Inlet ressure 5 5 P Q [m³/h] 6 8 Q [l/s] Q [m³/h] 5 5 TA t m [ C] 75 9 min [bar] x V x -5 V Series is also available for x - V Single-head ums are available with bronze housing, tye B. I/ Seed Seed.9.79 Seed Seed Seed.8.79 Seed x V x -5 V UPS 65-6/ F C C UPSD 65-6/ F D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65-6/ F 6/ / 85 / UPSD 65-6/ F 6/ / 85 / Shi. vol. [m ] 5

36 UPS 65-6/ F, UPSD 65-6/ F Series, 5 z UPS 65-6/ F, UPSD 65-6/ F Inlet ressure 6 6 t m [ C] 75 9 min [bar] Q [m³/h] x V x -5 V Series is also available for x - V I/ Seed Seed 7..8 Seed Seed Seed Seed P 6 8 Q [l/s] 8 6 Q [m³/h] TA Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 65-6/ F D D UPSD 65-6/ F D D B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65-6/ F 6/ / 85 / UPSD 65-6/ F 6/ / 85 / Shi. vol. [m ] 6

37 UPS 65-6/ F 8 Series, 5 z UPS 65-6/ F 8 Inlet ressure 6 6 t m [ C] 75 9 min [bar] x -5 V I/ Seed Seed Seed Q [m³/h] 6 8 Q [l/s] UPS 65-6/ F 8 x -5 V C P 8 6 Q [m³/h] TA B B D D L R / L T PN [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65-6/ F 8 6/ / 85 / Shi. vol. [m ] 7

38 UPS 65- F 8 Series, 5 z UPS 65- F 8 Inlet ressure Q [m³/h] Q [l/s] t m [ C] 75 9 min [bar].9..5 x -5 V UPS 65- F 8 I/ Seed Seed Seed x -5 V C P Q [m³/h] TA B B D D L R / L T PN [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65- F 8 6/ / 85 / Shi. vol. [m ] 8

39 UPS 65- F, UPSD 65- F Series, 5 z UPS 65- F, UPSD 65- F Inlet ressure Q [m³/h] t m [ C] 75 9 min [bar].9..5 x V x -5 V Series is also available for x - V I/ Seed Seed Seed Seed Seed Seed P Q [l/s] Q [m³/h] TA Single-head ums are available with bronze housing, tye B. x V x -5 V UPS 65- F C C UPSD 65- F C C B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B8 B9 D D Net Gross UPS 65- F 6/ / 85 / UPSD 65- F 6/ / 85 / Shi. vol. [m ] 9

40 UPS 65-8 F, UPSD 65-8 F Series, 5 z UPS 65-8 F, UPSD 65-8 F Inlet ressure P Q [m³/h] 6 8 Q [l/s] Q [m³/h] 5 5 TA t m [ C] 75 9 min [bar].7..5 x V x -5 V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS 65-8 F C C UPSD 65-8 F C C B B D D L R / B8 B9 L T 7 6 B B6 B6 D D L B R / L L T 7 6 PN * of bronze versions are arox. % higher. [kg]* L L L B B B B6 B6 B8 B9 D D Net Gross UPS 65-8 F 6/ / 85 / UPSD 65-8 F 6/ / 85 / Shi. vol. [m ]

41 UPS F Series, 5 z UPS F Inlet ressure 6 6 t m [ C] 75 9 min [bar] x -5 V I/ Seed Seed Seed Q [m³/h] P Q [l/s] x V x -5 V UPS F C C Q [m³/h] TA 9 99 B B D D L R / B8 B9 L T 7 6 Shi. PN [kg] vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS F 6/ /5 85 /

42 UPS 8- F 6, UPSD 8- F 6 Series, 5 z UPS 8- F 6, UPSD 8- F P Q [m³/h] Q [l/s] Q [m³/h] TA Inlet ressure t m [ C] 75 9 min [bar] x V x -5 V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed.. Seed.5.69 Seed Seed.5. x V x -5 V UPS 8- F 6 D D UPSD 8- F 6 D D B D L D R / B B8 B9 L PN 6 PN T B B6 B6 D B R / L L L PN 6 PN D T 85 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS 8- F x UPS 8- F x UPSD 8- F x UPSD 8- F x * of bronze versions are arox. % higher.

43 UPS 8-6 F 6, UPSD 8-6 F 6 Series, 5 z UPS 8-6 F 6, UPSD 8-6 F 6 Inlet ressure 5 5 P Q [m³/h] Q [l/s] 5 6 Q [m³/h] TA t m [ C] 75 9 min [bar] x V x -5 V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS 8-6 F 6 C C UPSD 8-6 F 6 D D B D L D R / B B8 B9 L PN 6 PN T B B6 B6 D B R / L L L PN 6 PN D T 85 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS 8-6 F x UPS 8-6 F x UPSD 8-6 F x UPSD 8-6 F x * of bronze versions are arox. % higher.

44 UPS 8- F 6, UPSD 8- F 6 Series, 5 z UPS 8- F 6, UPSD 8- F 6 Inlet ressure P Q [m³/h] Q [l/s] 5 6 Q [m³/h] 5 5 TA t m [ C] 75 9 min [bar] x V x -5 V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS 8- F 6 C C UPSD 8- F 6 C C B D L D R / B B8 B9 L PN 6 PN T B B6 B6 D B R / L L L PN 6 PN D T 85 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS 8- F x UPS 8- F x UPSD 8- F x UPSD 8- F x * of bronze versions are arox. % higher.

45 UPS - F 5, UPSD - F 5 Series, 5 z UPS - F 5, UPSD - F 5 Inlet ressure P Q [m³/h] Q [l/s] Q [m³/h] 5 5 TA t m [ C] 75 9 min [bar] x V x -5 V Single-head ums are available with bronze housing, tye B. I/ Seed Seed Seed Seed Seed Seed x V x -5 V UPS - F 5 D D UPSD - F 5 D D B D L D R / B B8 B9 L PN 6 PN T B B6 B6 D B R / L L L PN 6 PN D T 85 6 Shi. PN [kg]* vol. L L L B B B B6 B8 B9 D D Net Gross [m ] UPS - F x UPS - F x UPSD - F x UPSD - F x * of bronze versions are arox. % higher. 5

46 Accessories Series Accessories The following accessories are available for UPS, UPSD ums: rotection module relay module for single-head ums relay module kit for twin-head ums counter flanges (standard on ums for the UK) insulation kit (only single-head ums) base late (only single-head ums) blanking flanges (only twin-head ums). Counter flanges A counter flange kit includes these arts: two flanges with internal thread (ISO seal thread) or two flanges for welding/soldering two gaskets bolts. Product numbers of counter flanges R: Flange with internal thread (ISO seal thread). mm: Flange for welding/soldering. Pums with cast iron um housing Pressure stage UPS/UPSD PN UPS/UPSD PN UPS/UPSD 5 PN UPS/UPSD 65 PN UPS/UPSD 8 UPS/UPSD PN 6 PN PN 6 PN Size Product number R / 597 mm 597 R / 597 mm 597 R mm 598 R / mm 5598 R mm 5699 R mm 5698 R 5799 mm 5799 R 5798 mm 5798 Protection modules Relay module Pums with bronze um housing Pressure stage UPS PN UPS PN UPS 5 PN UPS 65 PN UPS 8 UPS PN 6 PN Size Relay modules for single-head ums. Product number R / 9679 mm 967 R / 597 mm 597 R mm 598 R / mm 5598 R mm 5699 R mm 5698 PN 6 R PN R Voltage [V] Product number x x 96 x Voltage [V] Product number x x 9666 x A relay module kit for twin-head ums includes these arts: two relay modules with screws and screwdriver two screwed cable entries one intermediate cable two wiring diagrams for terminal box covers. Voltage [V] Product number x x 969 x

47 Accessories Series Insulation kits Base late Single-head ums can be fitted with an insulation covering made of exanded olyroylene, EPP. The insulation kit, which is tailored to the individual um tye, has an insulating thickness corresonding to the nominal diameter of the um. xø The thermal conductivity of EPP is very low (. W/ m C), i.e. the insulating roerty is very good xø xø 6 The insulation kit encloses the entire um housing. It consists of two or three arts which are easily fitted around the um. xø8 xø T Fig. Insulation kit Product numbers of insulation kits Product number UPS - F UPS -6 F UPS - F UPS - F UPS -6/ F UPS -6/ F UPS - F UPS -8 F UPS 5- F UPS 5-6/ F UPS 5-6/ F UPS 5- F UPS 5-8 F UPS 65- F UPS 65-6/ F UPS 65-6/ F UPS 65- F UPS 65-8 F UPS 8- F UPS 8-6 F UPS 8- F UPS - F T 6 7 Fig. Base late Product numbers of base lates UPS -, -6, - UPS -, -6/, -6/, -, -8 UPS 5-, -6/, -6/, -, -8 UPS 65-6/, -, -8 UPS 65-, -6/ UPS 8-, -6, - UPS - UPS -85 UPS 5-85 UPS * Product numbers include a base late and two bolts. Only available for single-head ums. Product number*

48 Accessories Series Blanking flanges For twin-head ums a blanking flange with um housing seal is available as an otional extra. The blanking flange is used when servicing one of the ower heads to enable uninterruted oeration of the other. Product number of blanking flanges UPSD - F Product number UPSD -6 F UPSD - F UPSD - F UPSD -6 F 5 UPSD -6/ F 5 UPSD - F 5 UPSD 5- F 8 UPSD 5-6/ F UPSD 5-6/ F UPSD 5- F 8 UPSD 5-8 F UPSD 65- F UPSD 65-6/ F UPSD 65-6/ F 558 UPSD 65- F UPSD 65-8 F UPSD 8- F 6 UPSD 8-6 F 6 UPSD 8- F 6 UPSD - F

49 Further roduct documentation Series WebCAPS WebCAPS is a Web-based Comuter Aided Product Selection rogram available on WebCAPS contains detailed information on more than 85, Grundfos roducts in more than languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Relacement CAD drawings. Catalogue This section is based on fields of alication and um tyes, and contains technical data curves (Q,, P, P, etc) which can be adated to the density and viscosity of the umed liquid and show the number of ums in oeration roduct hotos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given um, such as data booklets installation and oerating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides roduct brochures. Service This section contains an easy-to-use interactive service catalogue. ere you can find and identify service arts of both existing and discontinued Grundfos ums. Furthermore, this section contains service videos showing you how to relace service arts. 9

50 Further roduct documentation Series Sizing This section is based on different fields of alication and installation examles, and gives easy ste-by-ste instructions in how to select the most suitable and efficient um for your installation carry out advanced calculations based on energy consumtion, ayback eriods, load rofiles, life cycle costs, etc. analyse your selected um via the built-in life cycle cost tool determine the flow velocity in wastewater alications, etc. Relacement In this section you find a guide to selecting and comaring relacement data of an installed um in order to relace the um with a more efficient Grundfos um. The section contains relacement data of a wide range of ums roduced by other manufacturers than Grundfos. Based on an easy ste-by-ste guide, you can comare Grundfos ums with the one you have installed on your site. When you have secified the installed um, the guide will suggest a number of Grundfos ums which can imrove both comfort and efficiency. CAD drawings In this section it is ossible to download two-dimensional (D) and three-dimensional (D) CAD drawings of most Grundfos ums. These formats are available in WebCAPS: Two-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. Three-dimensional drawings:.dwg, wireframe drawings (without surfaces).st, solid drawings (with surfaces).ert, E-drawings. WinCAPS WinCAPS is a Windows-based Comuter Aided Product Selection rogram containing detailed information on more than 85, Grundfos roducts in more than languages. The rogram contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-RO and udated once a year. Fig. WinCAPS CD-RO 5

51 5

52 Being resonsible is our foundation Thinking ahead makes it ossible Innovation is the essence V75 7 Rel. V75 5 GB Subject to alterations. GRUNDFOS A/S. DK-885 Bjerringbro. Denmark Telehone:

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz GRUNDFOS PRODUCT GUIDE VersaFlo UP, UPS Series circulator pumps Hz Contents ission General data Terminal box modules Applications Pumped liquids Type key 5 Nameplate 5 Performance range UPS pumps UP pumps

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

IN-LINE MIXED FLOW EXTRACTOR FANS FOR DUCT MOUNTING. 14 MODELS WITH AND WITHOUT TIMERS. SAFETY AND ACOUSTIC PERFORMANCES CERTIFIED

IN-LINE MIXED FLOW EXTRACTOR FANS FOR DUCT MOUNTING. 14 MODELS WITH AND WITHOUT TIMERS. SAFETY AND ACOUSTIC PERFORMANCES CERTIFIED VORTICE LINEO LONG LIFE.000 h ➀ ➀ ➁ ➁ Lineo series extractors have certified air flow, ressure (to UNI 10531:1995, corresonding to ISO 51) and noise levels (UNI EN ISO 371). Certification of these arameters

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Fire DNF, Fire HSEF GRUNDFOS DATA BOOKLET. Grundfos fire systems

Fire DNF, Fire HSEF GRUNDFOS DATA BOOKLET. Grundfos fire systems GRUNDFOS DATA BOOKLET Fire DNF, Fire HSEF Grundfos fire systems Fire systems with electrically owered ( Hz) ums aroved by the FM according to NFPA Contents NFPA standards Introduction to the NFPA 3 NFPA

More information

GRUNDFOS DATA BOOKLET. Hydro MPC. Booster systems with 2 to 6 pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro MPC. Booster systems with 2 to 6 pumps. 50/60 Hz GRUNDFOS DATA BOOKLET ydro MPC Booster systems with to ums 0/ z ydro MPC Table of contents. Product introduction Alications Benefits. Product data Performance range Product range, 0 z and 0/ z 7 Product

More information

CME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged

CME / CM-GE / DCME IN-LINE CONSTANT PRESSURE PUMPS. TECHNICAL DATA - CME/CM-GE single flanged CIRCUTORS ND IN-INE UMS ENERGY EFFICIENCY Circulation pups with in-line ports, suitable for installation in heating and air conditioning, refrigeration, and doestic hot water systes. Extreely versatile

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Chapter 1 Fundamentals

Chapter 1 Fundamentals Chater Fundamentals. Overview of Thermodynamics Industrial Revolution brought in large scale automation of many tedious tasks which were earlier being erformed through manual or animal labour. Inventors

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

KLME - KLPE / DKLME - DKLPE IN-LINE CONSTANT PRESSURE PUMPS

KLME - KLPE / DKLME - DKLPE IN-LINE CONSTANT PRESSURE PUMPS KLME - KLE / DKLME - DKLE IN-LINE CONSTNT RESSURE UMS CIRCULTORS ND IN-LINE UMS ENERGY EFFICIENCY ETING, IR CONDITIONING SYSTEMS, SOLR NEL ND OT TER SYSTEMS Circulator for hot or cold water with in-line

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

Chapter 9 Practical cycles

Chapter 9 Practical cycles Prof.. undararajan Chater 9 Practical cycles 9. Introduction In Chaters 7 and 8, it was shown that a reversible engine based on the Carnot cycle (two reversible isothermal heat transfers and two reversible

More information

Circulation pumps CATALOGUE. Wet rotor circulators and accessories. Heating, air-conditioning, solar, domestic water

Circulation pumps CATALOGUE. Wet rotor circulators and accessories. Heating, air-conditioning, solar, domestic water Circulation pumps Wet rotor circulators and accessories CATALOGUE eating, air-conditioning, solar, domestic water alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

Measurement of cyclone separator

Measurement of cyclone separator Measurement of cyclone searator. Aim of the measurement Cyclones are widely used in industry (in food and chemical industry, in energy technology and in buildings) to remove dust and other articles from

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

Theory of turbomachinery. Chapter 1

Theory of turbomachinery. Chapter 1 Theory of turbomachinery Chater Introduction: Basic Princiles Take your choice of those that can best aid your action. (Shakeseare, Coriolanus) Introduction Definition Turbomachinery describes machines

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

KLM / KLP / DKLM / DKLP TECHNICAL DATA - KLM/KLP SINGLE WITH OVAL FLANGES HEATING, AIR CONDITIONING, SOLAR PANEL AND HOT WATER SYSTEM IN-LINE PUMPS

KLM / KLP / DKLM / DKLP TECHNICAL DATA - KLM/KLP SINGLE WITH OVAL FLANGES HEATING, AIR CONDITIONING, SOLAR PANEL AND HOT WATER SYSTEM IN-LINE PUMPS CIRCULATORS AND up body and otor support in cast iron. N flanged connections with threaded for control pressure gauges. Technopolyer ipeller and carbon/ceraic echanical seal. Four-pole, asynchronous otor

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

Chapter 20: Exercises: 3, 7, 11, 22, 28, 34 EOC: 40, 43, 46, 58

Chapter 20: Exercises: 3, 7, 11, 22, 28, 34 EOC: 40, 43, 46, 58 Chater 0: Exercises:, 7,,, 8, 4 EOC: 40, 4, 46, 8 E: A gasoline engine takes in.80 0 4 and delivers 800 of work er cycle. The heat is obtained by burning gasoline with a heat of combustion of 4.60 0 4.

More information

Oil Temperature Control System PID Controller Algorithm Analysis Research on Sliding Gear Reducer

Oil Temperature Control System PID Controller Algorithm Analysis Research on Sliding Gear Reducer Key Engineering Materials Online: 2014-08-11 SSN: 1662-9795, Vol. 621, 357-364 doi:10.4028/www.scientific.net/kem.621.357 2014 rans ech Publications, Switzerland Oil emerature Control System PD Controller

More information

SGF. The metric thread forming connection

SGF. The metric thread forming connection SGF The metric thread forming connection Schriever SGF Our challenge: An economical solution Alication: Direct connections in cylindrical bores and casted bores. Schriever SGF -screws are metric thread-forming,

More information

The extreme case of the anisothermal calorimeter when there is no heat exchange is the adiabatic calorimeter.

The extreme case of the anisothermal calorimeter when there is no heat exchange is the adiabatic calorimeter. .4. Determination of the enthaly of solution of anhydrous and hydrous sodium acetate by anisothermal calorimeter, and the enthaly of melting of ice by isothermal heat flow calorimeter Theoretical background

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Installation and connecting possibilities 184XA. Electrical position monitoring

Installation and connecting possibilities 184XA. Electrical position monitoring Swing Clams with Sturdy Swing Mechanism To flange tye, with otional osition monitoring, doule acting, max. oerating ressure 35 ar Issue -5 E.53 lication Hydraulic swing clams are used for claming of workieces,

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009 University of North Carolina-Charlotte Deartment of Electrical and Comuter Engineering ECG 4143/5195 Electrical Machinery Fall 9 Problem Set 5 Part Due: Friday October 3 Problem 3: Modeling the exerimental

More information

Lecture 13 HYDRAULIC ACTUATORS[CONTINUED]

Lecture 13 HYDRAULIC ACTUATORS[CONTINUED] Lecture 1 HYDRAULIC ACTUATORS[CONTINUED] 1.5Acceleration and Deceleration of Cylinder Loads Cylinders are subjected to acceleration and deceleration during their oeration. Cylinders are decelerated to

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Chapter 12: Three-Phase Circuits

Chapter 12: Three-Phase Circuits Chater 1: Three-Phase Circuits 1.1 ntroduction 1. Balanced Three-Phase oltages 1.3 Balanced Wye-Wye connection 1.4 Balanced Wye-Delta Connection 1.7 Power in a Balanced System 1.1 NTRODUCTON A single-hase

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULATORS TECNICAL DATA EVOTRON WET ROTOR ELECTRONIC CIRCULATORS Operating range: from, -, m/h with head of up to metres. Pumped liquid temperature range: from -1 C to +11 C. Working

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

ALC. ALBATROSS Supply air terminal for large airflows

ALC. ALBATROSS Supply air terminal for large airflows ALBATROSS Supply air terminal for large airflows Quick facts Large airflows Suitable for cooling or heating Manual or motorised adjustment Pressure drop independent of selected spread pattern Can be used

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2 Globe Valve, Metal Construction The GEMÜ pneumatically operated /-way valve has a robust low maintenance aluminium actuator. The valve spindle is sealed by a self-adjusting gland packing providing low

More information

Operating instructions Pressure sensor PN / / 2007

Operating instructions Pressure sensor PN / / 2007 Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

THE FIRST LAW OF THERMODYNAMICS

THE FIRST LAW OF THERMODYNAMICS THE FIRST LA OF THERMODYNAMIS 9 9 (a) IDENTIFY and SET UP: The ressure is constant and the volume increases (b) = d Figure 9 Since is constant, = d = ( ) The -diagram is sketched in Figure 9 The roblem

More information

SKF actuators available for quick delivery. Selection guide

SKF actuators available for quick delivery. Selection guide SKF actuators available for quick delivery Selection guide A wide range of SKF actuators available for quick delivery Industrial actuator 24 Volt DC Load range 1 000 to 4 000 N Speed range 5 to 52 mm/s

More information

Study of the circulation theory of the cooling system in vertical evaporative cooling generator

Study of the circulation theory of the cooling system in vertical evaporative cooling generator 358 Science in China: Series E Technological Sciences 006 Vol.49 No.3 358 364 DOI: 10.1007/s11431-006-0358-1 Study of the circulation theory of the cooling system in vertical evaorative cooling generator

More information

Multifunctional Thermostatic Circulation Valve MTCV

Multifunctional Thermostatic Circulation Valve MTCV Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version

More information

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER

NKVE VERTICAL AXIS MULTISTAGE CENTRIFUGAL PUMPS WITH MCE/P INVERTER NKVE 1-1--3--6-9 VERTICAL AIS MULTISTAGE CENTRIFUGAL PUMPS WIT MCE/P INVERTER TECNICAL DATA Operating range: fro to 118 3 /h with head up to 31 etres. Puped liquid: clean, free of solids and abrasives,

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke. Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Precision Ball Screw/Spline

Precision Ball Screw/Spline 58-2E Models BNS-A, BNS, NS-A and NS Seal Outer ring Shim plate Seal Spline nut Seal Collar Shim plate Seal End cap Ball Outer ring Ball screw nut Outer ring Ball Retainer Retainer Outer ring Point of

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULTORS Technical Sheet ELECTRONIC CIRCULTORS FOR ETING ND IR CONDITIONING SYSTEMS Energ ia e y GENERL DT compliant with the 3 and european directive ErP 9//EC (ex EuP) pplications

More information

Homogeneous and Inhomogeneous Model for Flow and Heat Transfer in Porous Materials as High Temperature Solar Air Receivers

Homogeneous and Inhomogeneous Model for Flow and Heat Transfer in Porous Materials as High Temperature Solar Air Receivers Excert from the roceedings of the COMSOL Conference 1 aris Homogeneous and Inhomogeneous Model for Flow and Heat ransfer in orous Materials as High emerature Solar Air Receivers Olena Smirnova 1 *, homas

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

200kW HIGH FREQUENCY PRESS FOR DIELECTRIC HEATING. J. Tomljenovic

200kW HIGH FREQUENCY PRESS FOR DIELECTRIC HEATING. J. Tomljenovic 200kW HIGH FREQUENCY PRESS FOR DIELECTRIC HEATING J. Tomljenovic Plustherm Point GmbH Seminarstrasse 102, 5430 Wettingen, Switzerland ABSTRACT Uon introduction, the wood industry was hesitant to utilize

More information

Hotelling s Two- Sample T 2

Hotelling s Two- Sample T 2 Chater 600 Hotelling s Two- Samle T Introduction This module calculates ower for the Hotelling s two-grou, T-squared (T) test statistic. Hotelling s T is an extension of the univariate two-samle t-test

More information

Chapter 7 Energy Principle

Chapter 7 Energy Principle Chater 7: Energy Princile By Dr Ali Jawarneh Hashemite University Outline In this chater we will: Derive and analyse the Energy equation. Analyse the flow and shaft work. Derive the equation for steady

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q

More information

HEAT, WORK, AND THE FIRST LAW OF THERMODYNAMICS

HEAT, WORK, AND THE FIRST LAW OF THERMODYNAMICS HET, ORK, ND THE FIRST L OF THERMODYNMIS 8 EXERISES Section 8. The First Law of Thermodynamics 5. INTERPRET e identify the system as the water in the insulated container. The roblem involves calculating

More information

Tests for Two Proportions in a Stratified Design (Cochran/Mantel-Haenszel Test)

Tests for Two Proportions in a Stratified Design (Cochran/Mantel-Haenszel Test) Chater 225 Tests for Two Proortions in a Stratified Design (Cochran/Mantel-Haenszel Test) Introduction In a stratified design, the subects are selected from two or more strata which are formed from imortant

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady ELECTRONIC CIRCULATORS OR EATING AND COOLING SYSTEMS ErP eady TECNICAL DATA EVOSTA 2 WET ROTOR ELECTRONIC CIRCULATORS Operating range:,-3,6 m 3 /h with head up to 6,9 metres. Pumped liquid temperature

More information

MODELING THE RELIABILITY OF C4ISR SYSTEMS HARDWARE/SOFTWARE COMPONENTS USING AN IMPROVED MARKOV MODEL

MODELING THE RELIABILITY OF C4ISR SYSTEMS HARDWARE/SOFTWARE COMPONENTS USING AN IMPROVED MARKOV MODEL Technical Sciences and Alied Mathematics MODELING THE RELIABILITY OF CISR SYSTEMS HARDWARE/SOFTWARE COMPONENTS USING AN IMPROVED MARKOV MODEL Cezar VASILESCU Regional Deartment of Defense Resources Management

More information

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED w LED light engines Module SLE G7 ADV Modules SLE ADVANCED Product description For spotlights and downlights For operating with SELV Driver Luminous flux up to 6,18 lm at tp = 65 C High efficacy up to

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Actual exergy intake to perform the same task

Actual exergy intake to perform the same task CHAPER : PRINCIPLES OF ENERGY CONSERVAION INRODUCION Energy conservation rinciles are based on thermodynamics If we look into the simle and most direct statement of the first law of thermodynamics, we

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

Chapter 6: Efficiency and Heating. 9/18/2003 Electromechanical Dynamics 1

Chapter 6: Efficiency and Heating. 9/18/2003 Electromechanical Dynamics 1 Chapter 6: Efficiency and Heating 9/18/2003 Electromechanical Dynamics 1 Losses As a machine transforms energy from one form to another there is always a certain power loss the loss is expressed as heat,

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information