1 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E BELLATERRA (Barcelona) T F /LE766 Bellaterra: June 5 th, 2012 File number: 12/ Petitioner s reference: URSA IBÉRICA AISLANTES, S.A. Paseo Recoletos, nº Madrid TEST REPORT REQUESTED TEST: Measurement of the sound absorption in a reverberation room in accordance with the standard UNE-EN ISO 354:2004 of a sample of URSA Air Zero A2 mineral wool panels with 37 cm cavity. DATE OF TEST: May 25 th, 2012 TEST CARRIED OUT BY: Xavier Roviralta (Acoustics Laboratory - LGAI Technological Center) Service Quality Assurance Xavier Costa Manager of Acoustics LGAI Technological Center S.A. Applus+ guarantees that this work has been made in accordance with our Quality and Sustainability System, fulfilling the contractual conditions and legal norms. Within our improvement program we would be grateful if you would send us any commentary that you consider opportune, to the person in charge who signs this document, or to the Quality Manager of Applus+, in the following address: satisfaccion.cliente@appluscorp.com The reproduction of the present document is only allowed if done it its entirely. Only reports with an original signature or certified copies will have legal force. This document consists of 10 pages 0 of which are Appendixes. -page 1- LGAI Technological Center, S.A. inscrita en el Registro Mercantil de Barcelona, Tomo , Folio 1, Hoja nº B Inscripción 1ª CIF A

2 File number: 12/ Page number: SCOPE OF THE TEST The scope of this test is to determinate the sound absorption in accordance with the standard UNE-EN ISO 354:2004, of a sample of URSA Air Zero A2 25 mm thickness mineral wool panels, installed with a cavity of 37 cm. 2.- MEASUREMENT EQUIPMENT The equipment used in the test are the following: Spectrum analyzer id. number: (Bruel&Kjaer mod. Pulse) Microphone calibrator id. number: (Bruel&Kjaer mod. 4231) Microphones id. numbers: , , , , and (Bruel&Kjaer mod. 4943) Sound sources id. numbers: (AVM mod. DO12) and (CESVA mod. BP012) Noise generator with power amplifier id. number: (CESVA mod. AP600) Equalizer id. number: (INTER mod. EQ-9231) Thermo-hygrometer id. number: (Oregon Scientific mod. BA116) Tape measurer id. number: (Stanley mod. Powerlock) 3.- TEST PROCEDURE P3 P2 P4 F2 P5 P6 The test is carried out in accordance with LGAI Technological Center procedure C based on the European standard UNE-EN ISO 354:2004, Measurement of sound absorption in a reverberation room ; reverberation times of the room with and without sample are compared. The evaluation and rating is done in accordance with the European standard UNE-EN ISO 11654:1998. F1 P1 Around the sample 6 microphones positions (P1 to P6, in figure) and 2 sound sources (F1 and F2) positions are defined. Measurements are carried out exciting the room with pink noise and calculated from the measured reverberation times as specified in part 5.3.

3 File number: 12/ Page number: TEST SPECIMEN DESCRIPTION Test specimen has the commercial reference URSA Air Zero A2 and corresponds to mineral wool panels coated with an aluminium glass fiber fabric on one face and with a black glass fiber fabric on the other face. URSA Air Zero A2 is a panel of 3000 x 1200 x 25 mm (length, width and thickness) with tongue and groove on the sides. Tested panels are provided by the petitioner and received by the Acoustics Laboratory on May 23rd Images 1 and 2 URSA Air Zero A2 tested panels Images 3 and 4 Tongue and groove on the sides Image 5 Aluminium glass fiber fabric on one face and black glass fiber fabric on the other

4 File number: 12/ Page number: 4 Test specimen consists of 3 URSA Air Zero A2 panels, forming a rectangle of 3515 x 3000 mm, which means a test area of 10,55 m². The panels are placed inside the reverberation room with the face coated with black glass fiber fabric side up, mounted on a metal studs structure. The cavity under the panels is 37 cm. The perimeter edge of the test specimen is covered with an acoustically reflective frame made of medium density wooden boards (DM), in order to prevent the edges from absorbing sound and take into account only the upper face of test specimen. Images 6 to 8 Installation of test specimen into the reverberation room Image 9 Sample ready to be tested

5 File number: 12/ Page number: DEFINITIONS AND CLASSIFICATION 5.1. Reverberation time. Time, in seconds, that would be required for the sound pressure level to decrease by 60 db after the sound source has stopped Equivalent sound absorption area of a room. Hypothetical area of a totally absorbing surface without diffraction effects which, if it were the only absorbing element in the room, would give the same reverberation time as the room under consideration Equivalent sound absorption area of the test specimen, A T. Difference between the equivalent sound absorption area of the reverberation room with and without the test specimen. To calculate this parameter the average reverberation time in the reverberation room is measured with and without the test specimen. From these reverberation times the equivalent sound absorption area, A T, shall be calculated using the Sabine formula: 1 = A2 A1 = 55.3 V c 2T V (m c T m AT 2 1 where: c 1 and c 2 are the propagation speed of sound in air temperatures t 1 and t 2, V is the volume, in cubic metres, of the empty reverberation room, T 1 is the reverberation time, in seconds, of the empty reverberation room, T 2 is the reverberation time, in seconds, of the empty reverberation room after the test specimen has been introduced, m 1 and m 2 are the power attenuation coefficients, in reciprocal metres, of the empty reverberation room and with the test specimen, respectively. The value of m is calculated according to the International Standard ISO using the climatic conditions that have been present during the measurement. ) The value of m can be calculated from the attenuation coefficient, α, which is used in International Standard ISO in accordance with the formula: α m = 10 log (e)

6 File number: 12/ Page number: Sound Absorption Coefficient. The sound absorption coefficient, α s, of a plane absorber (or an array of identical objects), shall be calculated using the formula: where: α S = A T S A T is the equivalent sound absorption area of the test specimen, in square meters, S is the area, in square meters, of the test specimen. For discrete absorbers, the result should be expressed as equivalent sound absorption area per object, which is determined by dividing A T by the number of objects tested, n: A obj = A T n For a specified array of objects, the result should be given as equivalent sound absorption area of the whole configuration Practical sound absorption coefficient, α p. Value of sound absorption coefficient depending of frequency, based upon measurements of sound absorption according standard ISO 354, and calculated using the formula: where: α pi α = i 1 + α i α i 3 α pi is the practical sound absorption coefficient for the i th octave band, α i1, α i2 and α i3, are the sound absorption coefficients of the corresponding third-octave band within the i th octave band. Values are given with 2 decimal and rounded in steps of 0,05 until a maximum value of α pi = 1,00 in case of rounded average values > 1,00.

7 File number: 12/ Page number: Weighted sound absorption coefficient, α W. Single-number defined as the value of the reference curve, at the frequency of 500 Hz, after shifting it according to the method laid down. To evaluate the results of a measurement, the reference curve is shifted in steps of 0,05 towards the curve of practical sound absorption, α p, until the sum of the unfavourable deviations is as large as possible but no more than 0,10. An unfavourable deviation at a particular frequency occurs when the result of measurement is less than the reference curve. The set of reference values used for comparison with measurement results (reference curve) is specified in table below: 1.2 Frequency (Hz) Reference curve value Curva de referencia Frequency, Frecuencia, Hz Hz 5.7. Shape indicators, L. M. H. If a practical sound absorption coefficient, α pi, exceeds the shifted reference curve value on 0,25 or more, a shape indicator will be added. When excess happens at 250 Hz, indicator L is used. For 500 and 1000 Hz octave bands, indicator M is used. For 2000 Hz and 4000 Hz octave bands, indicator H is used Sound Absorption Classes. Sound Absorption classes A to E are another classification method described in the International Standard ISO and it is used in wide band applications. The single-number, α W, is compared with values given in the table below:

8 File number: 12/ Page number: 8 Sound absorption class α W A 0.90; 0.95; 1.00 B 0.80; 0.85 C 0.60; 0.65; 0.70; 0.75 D 0.30; 0.35; 0.40; 0.45; 0.50; 0.55 E 0.15; 0.20; 0.25 Not classified 0.00; 0.05; TEST CONDITIONS Reverberation room characteristics Shape: Parallelepiped Dimensions: 7,84 4,96 6,27 m Volume (V): 243,6 m 3 Total area (A T ): 238,2 m 2 Number of diffusers: 14 Size of diffuser: 1,5 m 2 Environmental conditions of reverberation room Room state: Empty With test specimen Temperature: Relative humidity: Air pressure: 22,3 ºC 49 % 1002 hpa 22,2 ºC 49 % 1002 hpa 7.- UNCERTAINTY OF RESULTS The uncertainty associated to the test has been calculated and it is available to the petitioner.

9 File number: 12/ Page number: REVERBERATION TIMES AND EQUIVALENT SOUND ABSORPTION AREA In following tables the reverberation time values of the test room with and without the test specimen are given, as well as the calculated equivalent sound absorption areas. Frequency (Hz) Reverberation time of the empty room, T 1 (s) Reverberation time of the room with the test specimen, T 2 (s) Equivalent sound absorption area, A T (m²) ,41 6,21 3, ,97 5,36 4, ,60 4,82 4, ,93 4,83 4, ,56 4,60 5, ,35 3,93 6, ,57 3,45 7, ,30 3,46 7, ,47 3,27 7, ,88 2,93 8, ,45 2,64 10, ,51 2,50 10, ,54 2,31 10, ,72 2,15 11, ,92 2,01 11, ,18 1,88 11, ,22 1,68 11, ,51 1,48 10,83

10 File number: 12/ Page number: RESULTS Sound absorption in accordance with UNE-EN ISO 354:2004 9/LE766 URSA IBÉRICA AISLANTES, S.A. Sound abs. coefficient, α S Test specimen: Freq. (Hz) α s URSA Air Zero A2, 25 mm mineral wool panels coated with an aluminium glass fiber fabric on one face and with a black glass fiber fabric on the other face. Tested with 37 cm cavity 1,2 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0, , , , ,46 Sound absorption coefficient, α S 250 0, Hz 315 0, , , , , , , , , , , , ,03 Practical sound absorption coefficient, α p 1,2 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 Sound abs. coef. 0,3 Ref. shifted. 0,2 Hz Practical sound absorption coef., α p Freq. (Hz) α p 125 0, , , , , ,00 Weighted sound absorption coefficient, α W = 0,80 (H) Sound absorption class: B It is highly recommended to use the single number "weighted sound absorption coefficient (α w )" together with frequency-dependent values of sound absorption coefficient. The results reported in this document relate only to the sample, product or item delivered to LGAI Technological Center the appointed day having been tested under the conditions established in this document.

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07 Test Report RI Acoustic Lab Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier 20 Feb. 07 Title Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier

More information

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM. RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON

More information

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM. REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM. Testing Procedure: AS ISO 354-2006 Testing Laboratory: Client:

More information

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS Report No. L/3237 Page 1 of 8 for Oscar Acoustics Michaels Lane Ash Kent TN15 7HT Dated: 24 July 2012 LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS Report Author: M Sawyer

More information

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 100 Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time Client: Kvadrat Soft Cells A/S Page 1

More information

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE A.B.N. 73 107 291 494 C O N S U L T I N G A C O U S T I C A L E N G I N E E R S MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE 100 mm ANCIENT STONE BRICK REPORT NUMBER: 4546-2 PREPARED FOR: Timbercrete Pty

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 462257-01 Sound Absorption Impact Sound Insulation Customer Desso B.V. Taxandriaweg 15 5142 PA Waalwijk NETHERLANDS Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room INTERNATIONAL STANDARD ISO 354 Second edition 2003-05-15 Acoustics Measurement of sound absorption in a reverberation room Acoustique Mesurage de l'absorption acoustique en salle réverbérante Reference

More information

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm DELTA Test Report TEST Reg. no. 100 Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm Performed for Fraster ApS DANAK 100/2275 Project no.:

More information

Measurement of Acoustic Properties of light weight concrete SL-Deck

Measurement of Acoustic Properties of light weight concrete SL-Deck DELTA Test Report TEST Reg. no. 100 Measurement of Acoustic Properties of light weight concrete SL-Deck Performed for Abeo A/S Project no.: I100486 Page 1 of 25 30 June 2014 DELTA Venlighedsvej 4 2970

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 471194-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2 LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C423-01 Type E Mounting Date of Test: 27/11/2009 Report Author: Mark Simms Test Number 2 Report Number 1644 Report Number 1644 Page

More information

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS Prepared for: MONOGLASS INC. 922-1200 West 73rd Avenue Vancouver, BC, Canada V6P 6G5 Prepared by: THE

More information

REPORT N CR

REPORT N CR Z Lab Srl Via Pisa, 5/7 37053 Cerea (VR) Italy Tel. +39 0442 410280 Fax +39 0442 418090 info@zeta-lab.it www.zeta-lab.it C.F./P.IVA 02984950788 Cap. Soc. 80.000 i.v. R.E.A. c/o C.C.I.A.A. Verona 376649

More information

Testing Procedure: AS ISO

Testing Procedure: AS ISO RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON

More information

Measurement of sound absorption coefficient for Fraster felt SpaceCover

Measurement of sound absorption coefficient for Fraster felt SpaceCover DELTA Test Report TEST Reg. no. 100 Measurement of sound absorption coefficient for Fraster felt SpaceCover Performed for Fraster ApS Project no.: I100645 Page 1 of 9 27 November 2014 DELTA Venlighedsvej

More information

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels. Technical Report Ref Number C/21387/R01a Date 06 April 2011 Project The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels Prepared for Rockfon Rockwool A/S

More information

Calcul des coefficients d'absorption alpha sabine

Calcul des coefficients d'absorption alpha sabine Calcul des coefficients d'absorption alpha sabine Selon Norme NFEN 20354 TEST n : 138G04-7 TYPE : Vinyl 340/360 g/m² DATE : 04 février 2005 SUPPORT : Echantillon collé sur plaque de BA13 DONNEES : Température

More information

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics DELTA Test Report TEST Reg. no. 100 Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object Performed for Flex Acoustics Project no.: T202611 Page 1 of 7 21 January 2013 DELTA Venlighedsvej

More information

Laboratory for Acoustics

Laboratory for Acoustics Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of mineral wool, type MW 35, manufacturer Knauf Insulation B.V. Report number A 3022-5E-RA-001 d.d. 22 maart 2016

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 481380-01 Sound Absorption Impact Sound Insulation Customer NEWSPEC CARPET (NINGBO) CO. LTD Cevin Yindong South Road NO. 399 315100 Ningbo CHINA VR Product textile floor covering This report

More information

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada FOR: Port Coquitlam, British Columbia, Canada Sound Absorption CONDUCTED: 2018-03-19 Page 1 of 7 ON: Model F202-2448 - Hercules absorption panels TEST METHOD Riverbank Acoustical Laboratories is accredited

More information

Renolit stretch ceilings

Renolit stretch ceilings Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor Report number A 3151-2E-RA-001 d.d. June 1, 2017 Laboratory for Acoustics Determination

More information

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT SCOPE OF WORK ASTM C423 SOUND ABSORPTION TESTING ON TEMPE, ROLLER SHADE FABRIC REPORT NUMBER I7375.01-113-11-R0 TEST DATE 08/14/18 ISSUE DATE 09/04/18

More information

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant: TEST REPORT This Test Report may only be reproduced in full. The test results are valid for the tested object only. Fibertex Nonwovens A/S Laboratory measurements of sound absorption coefficient Page 1

More information

Development of a small-scale reverberation room

Development of a small-scale reverberation room Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Development of a small-scale reverberation room Alexander Rasa Noise Control Research & Development, Pyrotek Pty Ltd, Sydney, Australia

More information

Consultancy Report Ref: 9383-R01

Consultancy Report Ref: 9383-R01 Consultancy Report Ref: 9383-R01 Submitted to: Prepared by: Mr Tim Simmons The Woolley Shepherd Secret Meadow Weekmoor Milverton Taunton TA4 1QE John Fithyan Laboratory Manager Approved for issue by: Andy

More information

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the Riss sued by an Accreditedd Testing Laboratory Contact person Malin Lindgren Sustainable Builtt Environment +46 10 516 50 722 malin.lindgren@ @sp.se 2016-01-11 5P08641-A/Engg 1 (8)) Stellan Bygård Rönnåsgatan

More information

Laboratory for Acoustics

Laboratory for Acoustics Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of a wooden linear ceiling/wall system, manufacturer Derako International Report number AB 1079-1E-RA d.d. November

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.2 LABORATORY MEASUREMENT

More information

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES FOR: Atlanta, GA Sound Absorption CONDUCTED: 2016-10-14 Page 1 of 8 ON: D-GIK Panels TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute of

More information

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation TFI Report 480781-01 Sound Absorption Impact Sound Insulation Customer egetaepper a/s Industrivej Nord 25 7400 Herning DENMARK Product textile floor covering This report includes 2 pages and 2 annex(es)

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 140-6 Second edition 1998-08-15 Acoustics Measurement of sound insulation in buildings and of building elements Part 6: Laboratory measurements of impact sound insulation of

More information

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV Report number A 3012-2E-RA-002 d.d. February 4, 2016 Laboratory for Acoustics

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6266/-SA6274 Revision 0 Subject: Sound Absorption Test Date: 17 February 2015 Contents: on Sound Absorption Data, One-third Octave

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6986/-SA6987 Revision 0 Subject: Sound Absorption Test Date: 01 February 2017 Contents: on Sound Absorption Data, One-third Octave

More information

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Phys. Elmar Schröder Telephone +49(89)85602 145 Elmar.Schroeder@mbbm.com

More information

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Germany Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M.Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING Report No. L/3194 Page 1 of 8 for EA Mimarlik Insaat Teknolojileri San.ve. Tic.Ltd.Sti 1420/3 Sokak NO. 22 Kizilkanat Silesi D Blok D.12 Alsancak Izmir Turkey Dated: 18 July 2011 LABORATORY MEASUREMENTS

More information

Part 2: Methods for special reverberation test rooms

Part 2: Methods for special reverberation test rooms Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 3743-2 Second edition 2018-02 Acoustics Determination of sound power levels of noise sources using sound pressure Engineering methods for small,

More information

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

Fabric REFLECTACOUSTIC

Fabric REFLECTACOUSTIC Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6956 Revision 1 Subject: Sound Absorption Test Date: 04 January 2017 Contents: on Sound Absorption Data, One-third Octave bands Sound

More information

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric TWIST MELANGE Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex Laboratory for Acoustics Determination of the sound insulation of sliding door constructions, manufactured by Metaflex Report number A 2641-1E-RA-002 d.d. January 26, 2015 Laboratory for Acoustics Determination

More information

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6712/-SA6713 Revision 0 Subject: Sound Absorption Test Date: 17 May 2016 Contents: on Sound Absorption Data, One-third Octave bands

More information

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA Report Member NLingenieurs ISO 9001 certified Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of curtains type Athens and Chicago, manufacturer Vescom Reportnumber

More information

Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7

Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7 Technical Note Measurement of Sound Absorption for Flex AqTube Performed for Flex Project no.: T202611 Page 1 of 7 19 December 2012 Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72

More information

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

RIVERBANK ACOUSTICAL LABORATORIES

RIVERBANK ACOUSTICAL LABORATORIES FOR: Indianapolis, IN. Sound Absorption CONDUCTED: 2015-10-06 Page 1 of 7 ON: LENRD Bass Trap TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute

More information

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Curtain fabric type Ace Manufacturer Kvadrat A/S

Curtain fabric type Ace Manufacturer Kvadrat A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10848-3 First edition 2006-04-01 Acoustics Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms Part 3: Application to light

More information

Laboratory and In Situ Sound Absorption Measurement under a Synthetized Diffuse Acoustic Field: a Case Study on Five Materials

Laboratory and In Situ Sound Absorption Measurement under a Synthetized Diffuse Acoustic Field: a Case Study on Five Materials Laboratory and In Situ Sound Absorption Measurement under a Synthetized Diffuse Acoustic Field: a Case Study on Five Materials Olivier Robin, Celse Kafui Amedin, Alain Berry, Noureddine Atalla, Olivier

More information

Study of Wenger Audience Seating Chair Absorption. Ron Freiheit

Study of Wenger Audience Seating Chair Absorption. Ron Freiheit Study of Wenger Audience Seating Chair Absorption Ron Freiheit January 22, 2002 Study of Wenger Audience Seating Chair Absorption Purpose The purpose of this project was to evaluate the acoustical performance

More information

Roller blind fabric PRIMACOUSTIC R

Roller blind fabric PRIMACOUSTIC R Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Fabric Medley Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Dominik Reif Telephone +49(89)85602 3566 Dominik.Reif@mbbm.com

More information

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de M. Eng. Philipp Meistring Telephone +49(89)85602 228 Philipp.Meistring@mbbm.com

More information

Report. Laboratory for Acoustics

Report. Laboratory for Acoustics 3 Report Member NLingenieurs ISO 9001 certified Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of ceiling panels type Lithos, manufacturer Rockfon, Rockwool

More information

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13 Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com

More information

A L I O N Technical Center. Test Report

A L I O N Technical Center. Test Report FOR: Beachwood, OH Sound Absorption CONDUCTED: 2017-10-30 Page 1 of 7 ON: Absorption Sheets TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S. Department of Commerce, National Institute

More information

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient Hyojin LEE, Tetsuya SAKUMA Graduate School of Frontier Sciences, University of Tokyo, Kashiwa, Japan. 1. Introduction

More information

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box

Users Manual. Marshall Day Acoustics. Double Panels Contact 33 Details Marshall Day 37.8 Acoustics PO Box New materials can be permanently entered into the materials.txt file. This is a simple ASCII text file. See the section New Materials for details of how to enter new materials. If desired you can send

More information

Radiated sound power estimates of building elements by means of laser Doppler vibrometry

Radiated sound power estimates of building elements by means of laser Doppler vibrometry Radiated sound power estimates of building elements by means of laser Doppler vibrometry N.B. Roozen, L. Labelle, M. Rychtáriková,2, C. Glorieux, D. Urbán 3, P. Za tko 3, H. Mullner 4 Laboratory of Acoustics,

More information

Witold MIKULSKI. Central Institute for Labour Protection National Research Institute Czerniakowska 16, Warszawa, Poland;

Witold MIKULSKI. Central Institute for Labour Protection National Research Institute Czerniakowska 16, Warszawa, Poland; ARCHIVES OF ACOUSTICS Vol. 38, No. 2, pp. 177 183 (2013) Copyright c 2013 by PAN IPPT DOI: 10.2478/aoa-2013-0020 Method of Determining the Sound Absorbing Coefficient of Materials within the Frequency

More information

SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS. Jukka Keränen, Petra Larm, Valtteri Hongisto

SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS. Jukka Keränen, Petra Larm, Valtteri Hongisto SIMPLE APPLICATION OF STI-METHOD IN PREDICTING SPEECH TRANSMISSION IN CLASSROOMS Jukka Keränen, Petra Larm, Valtteri Hongisto Finnish Institute of Occupational Health Laboratory of Ventilation and Acoustics

More information

Evaluation of standards for transmission loss tests

Evaluation of standards for transmission loss tests Evaluation of standards for transmission loss tests M. Cassidy, R. K Cooper, R. Gault and J. Wang Queen s University Belfast, School of Mechanical and Aerospace Engineering, Ashby Building, Stranmillis

More information

ISO 3741 INTERNATIONAL STANDARD

ISO 3741 INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 3741 Fourth edition 2010-10-01 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Precision methods for reverberation

More information

Report. Laboratory for Acoustics

Report. Laboratory for Acoustics Report Member ONRI ISO-9001: 2000 certified Laboratory for Acoustics Determination of the sound absorption (reverberation room method) and the sound insulation of a noise barrier type NoiStop Wood, manufacturer

More information

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones

Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones CFA 2018 - Le Havre Sound power level measurement in diffuse field for not movable sources or emitting prominent discrete tones F. Bessaca et P. Cellardb a CETIAT, Domaine Scientifique de la Doua, 25,

More information

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE Wan-Ho Cho, Hyu-Sang Kwon, and Ji-Ho Chang Korea Research Institute of Standards and Science, Center

More information

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION 000059.doc/0 EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION M. GARAI, P. GUIDORZI DIENCA, University of Bologna, Viale Risorgimento 2, 40136,

More information

DETERMINATION OF AIRBORNE SOUND POWER LEVELS EMITTED BY GEAR UNITS

DETERMINATION OF AIRBORNE SOUND POWER LEVELS EMITTED BY GEAR UNITS DETERMINATION OF AIRBORNE SOUND POWER LEVELS EMITTED BY GEAR UNITS CONTENTS... PAGE 0 SCOPE... 4 1 REFERENCE... 4. 2. TERMS. DEFINITIONS AND UNITS... 4 3. INSTRUMENTATION... 6 4. TEST REQUIREMENTS... 6

More information

Byggakustik Mätning av ljudabsorption i efterklangsrum (ISO 354:2003)

Byggakustik Mätning av ljudabsorption i efterklangsrum (ISO 354:2003) SVENSK STANDARD SS-EN ISO 354 Fastställd 2003-06-18 Utgåva 1 Byggakustik Mätning av ljudabsorption i efterklangsrum (ISO 354:2003) Acoustics Measurement of sound absorption in a reverberation room (ISO

More information

TFI Report Impact Sound Insulation

TFI Report Impact Sound Insulation TFI Report 462062-05 Impact Sound Insulation Customer Unifloor BV Munsterstraat 24 748 EV Deventer NETHERLANDS Product floor underlay Redupax This report includes 2 pages and annex(es) Responsible at TFI

More information

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool Report Member ONRI ISO-9001: 2000 certified Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool Reportnumber A 1978-1E-RA

More information

Acoustic design of lightweight cabin walls for cruise ships

Acoustic design of lightweight cabin walls for cruise ships Acoustic design of lightweight cabin walls for cruise ships A. Treviso 1, M. G. Smith 1 1 ISVR Consulting, University of Southampton University Road, SO17 BJ1, Southampton, United Kingdom e-mail: mgs@isvr.soton.ac.uk

More information

SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS

SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS J Riionheimo N Näveri T Lokki H Möller Aalto University, Akukon Ltd. Helsinki, Finland Akukon Ltd. Helsinki, Finland Aalto University, Espoo,

More information

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements. Edinburgh, Scotland EURONOISE 00 October - An examination of some aspects of the use of ISO 0 Part and in field measurements. Philip R Dunbavin a Philip Dunbavin Acoustics Ltd (ANC) Keepers House, Deans

More information

series KAT Acoustic air transfer units

series KAT Acoustic air transfer units series Acoustic air transfer units www.koolair.com 1 Acoustic Air Transfer Unit CONTENTS Acoustic Air Transfer Unit 2 Dimensions 3 Technical Data 5 Product Codes 7 2 Acoustic Air Transfer Unit - Description

More information

Acoustics Attenuation of sound during propagation outdoors Part 2: General method of calculation

Acoustics Attenuation of sound during propagation outdoors Part 2: General method of calculation ISO 9613-2 INTERNATIONAL STANDARD First edition 1996-12-15 Acoustics Attenuation of sound during propagation outdoors Part 2: General method of calculation Acoustique Attenuation du son lors de sa propagation

More information

The effect of an edge on the measured scattering coefficients in a reverberation chamber based on ISO

The effect of an edge on the measured scattering coefficients in a reverberation chamber based on ISO Proceedings of the International Symposium on Room Acoustics, ISRA 2010 29-31 August 2010, Melbourne, Australia The effect of an edge on the measured scattering coefficients in a reverberation chamber

More information

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES P-7 THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES RYU, YUNSEON BRUEL & KJAER SOUND & VIBRATION MEASUREMENT A/S SKODSBORGVEJ 307 NAERUM 2850 DENMARK TEL : +45 77 41 23 87 FAX : +45 77

More information

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method INTERNATIONAL STANDARD ISO 5136 Second edition 2003-04-01 Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method Acoustique Détermination de la

More information

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room Proceedings of ACOUSTICS 6 20-22 November 6, Christchurch, New Zealand Some issues in measurement of the random-incidence scattering coefficients in a reverberation room Young-Ji Choi, Dae-Up Jeong and

More information

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d Sound Absorption Test Intertek kraft paper softwall + softblock modular system m o l o d e s i g n, l t d 1470 Venables Street V a n c o u v e r, B. C. C a n a d a V 5 L 2 G 7 t +1 604 696 2501 f +1 604

More information

Laser scanning vibrometry measurements on a light weight building element

Laser scanning vibrometry measurements on a light weight building element Laser scanning vibrometry measurements on a light weight building element N.B. Roozen, M. Rychtáriková, Katholieke Universiteit Leuven, Laboratory for Acoustics and Thermal Physics (ATF), Department of

More information

TFI Report Impact Sound Insulation

TFI Report Impact Sound Insulation TFI Report 462062-06 Impact Sound Insulation Customer Unifloor BV Munsterstraat 24 748 EV Deventer NETHERLANDS Product floor underlay Redupax This report includes 2 pages and annex(es) Responsible at TFI

More information

Design and Acoustics Brought into Harmony

Design and Acoustics Brought into Harmony Acoustics and sound absorption General principles Design and Acoustics Brought into Harmony Acoustics Brochure values Acoustics and sound absorption General principles Table of Contents Page Principles

More information

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room Investigations on real-scale experiments for the measurement of the scattering coefficient in the reverberation room 43.55.BR Lieven De Geetere, Gerrit Vermeir K.U.Leuven, Laboratory for Building Physics

More information

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method INTERNATIONAL STANDARD ISO 10494 Second edition 2018-04 Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method Turbines et groupes de turbines Mesurage du bruit aérien

More information

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices) issued by an Accredited Testing Laboratory Date Reference Page 2011-05-16 PX03759-02-5A 1 (3) Contact person Xuetao Zhang Energy Technology +46 10 516 50 21, xuetao.zhang@sp.se SP Wood Technology Att:

More information

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia) SIA * R & D AKUSTIKA * ============================================================================================= LATVIJAS REPUBLIKA, LV - 1067, R GA, KURZEMES PROSPEKTS 3, Re istr. Nr. : LV 010310045

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.1 DESIGN OF TERMINATING

More information

Transmission loss of rectangular silencers using meso-porous and micro-perforated linings

Transmission loss of rectangular silencers using meso-porous and micro-perforated linings Transmission loss of rectangular silencers using meso-porous and micro-perforated linings T.E.Vigran Acoustic Group, Department of Electronics and Telecommunications, Norwegian University of Science and

More information