G_Series. Gas Ring Blowers US Edition

Size: px
Start display at page:

Download "G_Series. Gas Ring Blowers US Edition"

Transcription

1 _Series as Ring Blowers US Edition

2 History In May 2002 the Nash Engineering Company, USA, and elmo vacuum technology mbh, ermany, formerly a Siemens subsidiary, merged to create a global leader in vacuum technology. Headquartered in Connecticut, the company has manufacturing sites in the US, Brazil, ermany and China. A global network of sales and service centers makes sure that nash_elmo is nearby when our customers need us. Let's do it. Together. 2 nash_elmo Industries _Serie

3 _Series as ring blowers and compressors Suction capacity V 1,800 cfm 1, _ _ _ inch H 2 O Vacuum Pressure Some technologies are so good that it s hard to improve them. as ring blowers from nash_elmo are such an example. They ve proven their reliability in service for many decades, performing flawlessly day in and day out with virtually no down time. Existing noise levels have been lower than that of most other vacuum pumps and compressors. _Series pumps and compressors are used for conveying gases and gas-air mixtures. Main features: Low noise level Low Maintenance Reliable and built-to-last Robust yet light-weight Can be installed in any axial orientation Wide performance range For use worldwide (UL/CSA/IEC/EN approval) 50/60 Hz voltage range motors ATEX 94/9 E Contents Series overview 4-5 Selection and ordering information _ _ _200e (with frequency converter) _ _400e (with frequency converter) Accessories selection and ordering information Dimensions gas ring compressors Dimensions accessories Annex Application examples Conversion tables 76 Physical basics for blower applications eneral safety information Quality 81 ATEX 82 Footnotes and Voltage Overview 83 nash_elmo Industries _Series 3

4 _Series as ring blowers and compressors _100 Driven via an electronically commutated, permanent-field DC motor. Infinitely variable over the entire power range. _200 Single-stage version. _200 Two-stage, for tougher requirements. _200e With integrated frequency converter for high volume flows and/or automatic modification to changing loads. Applications Pneumatic conveying systems Lifting and holding of parts by vacuum Packaging machines Aeration of sewage-treatment plants Filling of bags/bottles/hoppers Soil remediation Thermoforming Sorting/enveloping of letters Food-processing Laser printers Dental suction equipment Paper processing Printers/copiers Textile machines Aeration of fish ponds as analysis Swimming-pool equipment/whirlpools _400 Single-stage, for high pressure ranges. _400 Multi-stage, reliability for high differential pressures _400e With integrated frequency converter. 4 nash_elmo Industries _Series _200e and _400e also available with external frequency converter

5 The _Series vacuum pumps and compressors are available in a wide selection for performance ranges up to 1,770 cfm and differential pressures of up to 400 inch H 2 O. They cover the most varied requirements flexibly and powerfully. If frequency converters are used, any operating point can be precisely selected, maintained and controlled. These converters can be integrated into the machine but are also available as stand-alone models. Ex stock for use world-wide The _Series pumps and compressors feature voltage range motors for 50 and 60 Hz in protection class IP 55 (insulation class F) and are UL 507 and CSA No. 113 approved. This makes them the ideal solution for world-wide use: they can be used without modifications or tests in Europe, Asia and America. They are mostly available ex stock. Large range of accessories nash-elmo offers a large range of accessories for our _series that are ideally suited for these machines. A special sound protection hood was designed for noise sensitive environments such as schools, living quarters, hospitals and production facilities. They can be installed outside, are maintenance-free and easy to transport. An additional rigid silencer is now available for the _200 that will reduce the noise level even further. _Series operating principle The impellers in the _Series machines are mounted directly on the motor shaft for noncontact compression entirely without friction. Maximum operational reliability, even at high differential pressures, is ensured by the arrangement of the bearings outside the compression chamber. The gas is taken in through the inlet 1. As it enters the side channel 2, the rotating impeller 3 imparts velocity to the gas in the direction of rotation. Centrifugal force in the impeller blades accelerates the gas outward and the pressure increases. Every rotation adds kinetic energy, resulting in further increase of pressure along the side channel. The side channel narrows at the rotor, sweeping the gas off the impeller blades and discharging it through the outlet silencer 4 where it exits the pump. 2 side channel 3 impeller 4 outlet 1 inlet nash_elmo Industries _Series 5

6 _100

7 _100 The smallest gas ring blower on the market With a height and width of approx. 5 inches and a depth of approx. 2.4 inches, the _100 blowers have the size of a CD and are the smallest gas ring vacuum blowers available on the market. Furthermore, the adjustable volume flow of the machines ensures that only the exact performance required is actually being supplied not more. These blowers are employed primarily in fine mechanical and medical technology applications. With their robust and built-to-last design, they are also used in other industries such as mechanical engineering. The _100 is driven via an electronically commuted DC motor. This guarantees a high level of efficiency and maintenance-free operation for more than 20,000 operating hours. The operating electronics are a standard feature of the machines which allow infinitely variable control of speed and output of the blower. Selection diagram, ordering information, pages 8-9 accessories, dimensions

8 _Series _100 The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Vacuum-compressor selection diagram 24 u_5351b cfm Suction capacity C100 C in H 2 O 80 (Vacuum) Total pressure difference (Pressure) Selection and ordering information Curve no. Control voltage Order no. Speed n ( V DC) min -1 V output hp Rated voltage V current A Max. differential vacuum compump pressor in H 2 O in H 2 O Sound pressure level 1) db(a) IP66, with hood and integrated electronics C100 2BH AB DC n max ± ± ± ± ± IP 66, with external electronics C150 2BH AA53 2) DC Variant without hood available on request. 1) Measuring-surface sound-pressure level acc. to EN , measured at 1 m distance with closed suction and pressure side at 7,400 min -1. Tolerance: ± 3 db(a). 2) External operating electronics compulsory Weight lbs 8 nash_elmo Industries _Series

9 Accessories for 2BH100 Delivery loose Order no. Delivery with the pump abbreviation 1) External electronics (Variotronic) 2), loose 2BX4 130 B Set of plugs 3), loose, eight-pole, for connecting motor Variotronic, 2BX4 131 B20 comprising: 1 x socket casing, 3 x socket contact AW 20 5 x socket contact AW 26, 2 x 1 each spare contact Suction filter 2BX4 134 B Silencer 2BX4 135 B Rubber buffer (1 set = 4 pieces) (rubber metal bearing) 2BX4 132 B31 1) Please add a -Z to the order number and add the abbreviation as follows: Example 2BH AB32-Z B30 + B31 2) With ambient temperatures over 25 C the operating speed may be less depending on the cooling of the electronics system. 3) Note: Pliers for the socket contacts are not included with delivery; obtainable from Molex Deutschland/Heilbronn; ermany Fax +49 (0) / ; Type Weight approx. lbs Dimensions for 2BH100 (inch) E 1 K Ød1 Ød2 ØR S B2 B1 B D C F4 F F2 u_5347b F3.87 for 2BH AA53.87 Ø.17 E 2.75 Type B B1 B2 C D Ø d1 Ø d2 E F F2 F3 F4 1 K Ø R S 2BH AB BH AA Dimensional drawings are also available as.dxf files on request. Dimensions of accessories for 2BH100 (inch) External electronics (Variotronic) 2BX4 130 Rubber buffer 2BX4 132 Set of plugs 2BX4 131 S1 PV-5348 R1 R S1 Control signal e * ) S2 N R2 F A B1 B S2 Motor connection b c d f a PV-5350 PV-5349 Order no. A B B1 F N Ø R R1 R2 2BX Order no. a b c d e f 2BX4 132 Ø M 4 M 4 *) 2BX4 131: Pliers not included in scope of order nash_elmo Industries _Series 9

10 _200 _200 _200 single and multi-stage _200e with integrated or external frequency converter

11 _200 Classics with innovative technology With their high inlet volume flow (up to 1,470 cfm) and a differential pressure of up to 313 inch H 2 O, our low noise _series allrounders have earned their reputation and convinced thousands of customers all over the world. They are reliable, low-maintenance and durable and are the first choice for many applications in mechanical engineering. When used with a frequency converter the performance of the _200 pumps and compressors can be increased considerably. The _200 machines are UL/CSA approved and can be used without further testing all over the world. Available at short notice or ex stock and also as ATEX certified models, the _200 family is a classic that has proven its innovative quality. Selection diagrams and tables for _200, pages vacuum and compressor mode, 50 and 60 Hz _200e, pumps and compressors with speed control pages and frequency converter Details on voltages, footnotes etc. see page 83

12 _Series _200, 50 Hz The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Selection diagram, vacuum operation Suction capacity V u_5013j 1200 cfm A m 3 /h A A A A384 A A A344= A330 A346 A A A286 A282 A284 A236=A238 A202 A334 A234 A200 A354 A274 A322 A232 A272 A226 A170= A172s A224 A A A172 A140 A132 5 A A110=A110s in H 2 O 0 Total pressure difference (Vacuum) A230 A262= A264 p A270 A222 A220 A260 A210 A192s A192 A180 A194 A196s A160 A170s A162s= A196 A164s A162 A132s A190 A180s A130 A150s A120= A120s nash_elmo Industries _Series

13 Selection and ordering information for 50 Hz, 3AC, IP55 Curve no. Motor Order no. Rated output voltage 4) current hp V A Weight approx. lbs Sound pressure level 1) db(a) Vacuum-relief valve 2) Items x type 2BX2... Pressure-relief valve 2) Items x type 2BX2... A B / Y 2.1 B / 1.2 Y 2BH A H A B / Y 1.38 B / 0.8 Y 2BH A H A B / Y 2.1 B / 1.2 Y 2BH A H x 110/141 1 x 111/143 A B / Y 2.6 B / 1.5 Y 2BH A H x 110/141 1 x 111/143 A B / Y 3.8 B / 2.2 Y 2BH H H x 110/141 1 x 111/143 A B / Y 2.8 B / 1.6 Y 2BH A H A B / Y 3.8 B / 2.2 Y 2BH A H x 110/141 1 x 111/143 A B / Y 4.2 B / 2.4 Y 2BH A H x 110/141 1 x 111/143 A B / Y 6.6 B / 3.8 Y 2BH A H x 110/141 1 x 111/143 A B / Y 7.5 B / 4.3 Y 2BH H H x 110/141 1 x 111/143 A B / Y 9.7 B / 5.6 Y 2BH H H x 110/141 1 x 111/143 A B / Y 7.5 B / 4.3 Y 2BH A H A B / Y 4.2 B / 2.4 Y 2BH A H x 110/145 1 x 111/147 A B / Y 6.6 B / 3.8 Y 2BH A H x 110/145 1 x 111/147 A B / Y 7.5 B / 4.3 Y 2BH A H x 110/145 1 x 111/147 A B / Y 9.7 B / 5.6 Y 2BH A H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH H H x 110/145 1 x 111/147 A B / Y 17.4 B / 10 Y 2BH H H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH A H A B / Y 8.5 B / 4.9 Y 2BH A H x 110/145 2 x 111/147 A B / Y 10.0 B / 5.8 Y 2BH A H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH A H x 110/145 1 x 111/147 A B / Y 16.5 B / 9.5 Y 2BH A H x 110/145 1 x 111/147 A B / Y 9.7 B / 5.6 Y 2BH H H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH H H x 110/145 1 x 111/147 A B / Y 17.3 B / 10 Y 2BH H H x 110/145 1 x 111/147 A B / Y 23 B / 13.3 Y 2BH H H x 110/145 1 x 111/147 A B / Y 29 B / 16.7 Y 2BH H H x 110/145 1 x 111/147 A B / Y 16.4 B / 9.5 Y 2BH H x 110/145 3 x 111/147 A B / Y 23 B / 13.3 Y 2BH H x 110/145 2 x 111/147 A B / Y 29 B / 16.7 Y 2BH H x 110/145 1 x 111/147 A B / Y 16.4 B / 9.5 Y 2BH A H x x 111 A B / Y 23 B / 13.3 Y 2BH A H x x 111 A B / Y 29 B / 16.7 Y 2BH A H x x 111 A B / Y 23 B / 13.3 Y 2BH H H x x 111 A B / Y 29 B / 16.7 Y 2BH H H x x 111 A B / Y 48.5 B / 28 Y 2BH H H x x 111 A B / Y 56.5 B / 32.5 Y 2BH H H x x 111 A B / Y 30.8 B / 17.6 Y 2BH J H x x 151 A B / Y 48.5 B / 28 Y 2BH J H x x 111 A B / Y 33 B / 19.1 Y 2BH A H x x 151 A B / Y 48.5 B / 28 Y 2BH A H x x 111 A B / Y 64.5 B / 37 Y 2BH A H x x 111 A B / Y 48.5 B / 28 Y 2BH H H x x 151 A B / Y 60 B / 35 Y 2BH H H x x 151 A B / Y 69 B / 40 Y 2BH H H x x 111 A B / Y 90 B / 52 Y 2BH H H x x 111 A B / Y 33 B / 19.1 Y 2BH A H x x 151 A B / Y 48.5 B / 28 Y 2BH A H x x 151 A B / Y 64.5 B / 37 Y 2BH A H x x 111 A B / Y 59 B / 34 Y 2BH H 2 6 3) x x 153 A B / Y 69 B / 40 Y 2BH H 3 6 3) x x 153 A B / Y 90 B / 52 Y 2BH H 4 6 3) x x 153 Selection and ordering information for 50 Hz, 1AC, IP55 A110s / 1.5 / 2BH A A A110s / / BH A V A120s / / 1.6 2BH A V A132s / / 2.7 2BH A V x 110/141 1 x 111/143 A150s / 4.1 / 2BH A A A162s / 5.2 / 2BH A A x 110/141 1 x 111/143 A164s / / 7.3 2BH A V x 110/141 1 x 111/143 A170s / 9.1 / 2BH H A x 110/141 1 x 111/143 A172s / / 11 2BH H V x 110/141 1 x 111/143 A180s / 7.9 / 2BH A A A192s / 6.9 / 2BH A A x 110/145 1 x 111/147 A196s / / 11 2BH A V x 110/145 1 x 111/147 Details on voltages, footnotes etc. see page 83. nash_elmo Industries _Series 13

14 _Series _200, 50 Hz The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Selection diagram, compressor operation Suction capacity V cfm A150s A350 A190 A180s A180 A160 A380 A320 A260 A220 A192 A192s A352 A194 A196s A330 A270 A222 A210 A382 A230 A340 A280 A232 A262 A384 A264 A172s A170s A342 A322 A234 A200 A344 A346 A236 u_5014l A170 A A162=A162s A A196 A120= A150 A164s A120s A130=A132s A164 A A132 A A110=A110s 0 0 in H A224 A332 A354 A282 A272 A274 A334 Total pressure difference (Pressure) A284 A286 A238 p m 3 /h nash_elmo Industries _Series 14

15 PV nash_elmo Industries _Series 14 Please open this page for selection diagram. _Series _200, 50 Hz Selection and ordering information for 50 Hz, 3AC, IP55 Curve no. Motor Order no. Weight Soundpressure valve 2) valve 2) Vacuum-relief Pressure-relief Ratedoutput voltage4) current level 1) Items x type Items x type approx. kw V A Available ex stock kg db(a) 2BX2... 2BX2... A B / Y 2.1 B / 1.2 Y 2BH A H A B / Y 1.38 B / 0.8 Y 2BH A H A B / Y 2.1 B / 1.2 Y 2BH A H x 110/141 1 x 111/143 A B / Y 2.6 B / 1.5 Y 2BH A H x 110/141 1 x 111/143 A B / Y 3.8 B / 2.2 Y 2BH H H x 110/141 1 x 111/143 A B / Y 2.8 B / 1.6 Y 2BH A H A B / Y 3.8 B / 2.2 Y 2BH A H x 110/141 1 x 111/143 A B / Y 4.2 B / 2.4 Y 2BH A H x 110/141 1 x 111/143 A B / Y 6.6 B / 3.8 Y 2BH A H x 110/141 1 x 111/143 A B / Y 7.5 B / 4.3 Y 2BH H H x 110/141 1 x 111/143 A B / Y 9.7 B / 5.6 Y 2BH H H x 110/141 1 x 111/143 A B / Y 7.5 B / 4.3 Y 2BH A H A B / Y 4.2 B / 2.4 Y 2BH A H x 110/145 1 x 111/147 A B / Y 6.6 B / 3.8 Y 2BH A H x 110/145 1 x 111/147 A B / Y 7.5 B / 4.3 Y 2BH A H x 110/145 1 x 111/147 A B / Y 9.7 B / 5.6 Y 2BH A H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH H H x 110/145 1 x 111/147 A B 10 B 2BH H H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH A H A B / Y 8.5 B / 4.9 Y 2BH A H x 110/145 2 x 111/147 A B / Y 10.0 B / 5.8 Y 2BH A H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH A H x 110/145 1 x 111/147 A B 9.5 B 2BH A H x 110/145 1 x 111/147 A B / Y 9.7 B / 5.6 Y 2BH H H x 110/145 1 x 111/147 A B / Y 12.5 B / 7.2 Y 2BH H H x 110/145 1 x 111/147 A B 10 B 2BH H H x 110/145 1 x 111/147 A B 13.3 B 2BH H H x 110/145 1 x 111/147 A B 16.7 B 2BH H H x 110/145 1 x 111/147 A B 9.5 B 2BH H x 110/145 3 x 111/147 A B 13.3 B 2BH H x 110/145 2 x 111/147 A B 16.7 B 2BH H x 110/145 1 x 111/147 A B 9.5 B 2BH A H x x 111 A B 13.3 B 2BH A H x x 111 A B 16.7 B 2BH A H x x 111 A B 13.3 B 2BH H H x x 111 A B 17.6 B 2BH H H x x 111 A B 28 B 2BH H H x x 111 A B 32.5 B 2BH H H x x 111 A B 16.7 B 2BH J H x x 151 A B 28 B 2BH J H x x 111 A B 19.1 B 2BH A H x x 151 A B 28 B 2BH A H x x 111 A B 37 B 2BH A H x x 111 A B 28 B 2BH H H x x 151 A B 35 B 2BH H H x x 151 A B 40 B 2BH H H x x 111 A B 52 B 2BH H H x x 111 A B 18.2 B 2BH A H x x 151 A B 28 B 2BH A H x x 151 A B 37 B 2BH A H x x 111 A B 34 B 2BH H 2 73) x x 153 A B 40 B 2BH H 3 73) x x 153 A B 52 B 2BH H 4 73) x x 153 Selection and ordering information for 50 Hz, 1AC, IP55 A110s / 1.5 / 2BH A A A110s / / BH A V A120s / / 1.6 2BH A V A132s / / 2.7 2BH A V x 110/141 1 x 111/143 A150s / 4.1 / 2BH A A A162s / 5.2 / 2BH A A x 110/141 1 x 111/143 A164s / / 7.3 2BH A V x 110/141 1 x 111/143 A170s / 9.1 / 2BH H A x 110/141 1 x 111/143 A172s / / 11 2BH H V x 110/141 1 x 111/143 A180s / 7.9 / 2BH A A A192s / 6.9 / 2BH A A x 110/145 1 x 111/147 A196s / / 11 2BH A V x 110/145 1 x 111/147 The performance curves are valid for pumping air at 15 C at the inlet flanges with an air pressure of 1,013 mbar and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 25 C. Selection diagram, compressor operation m 3 /h Suction capacity 1500 A380 m 3 /min A382 A A A A A342 A330 A332 A344 A A A334 A280 A A270 A354 6 A A282 5 A230 A272 A284 A286 4 A220 A232 A A222 A262 3 A A190 A274 A210 A A192s A A180s A192 1,5 A180 A194 A A172s A264 A150s A160 A196s A170 A170s 60 A162=162s A226 A ,8 A A164s A120= A196 A164 A120s 0,5 A130=A132s 20 A172 A132 A140 0,2 10 A110=A110s 0 0 mbar Total pressure difference (Pressure) Details on voltages, footnotes etc. see page 82. nash_elmo Industries _Series 13

16 _Series _200, 60 Hz The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Selection diagram, vacuum operation Suction capacity V u_5011j 1200 A A383 cfm m 3 /h A385 A A341 A A A345= A331 A347 A A333 A281 A A335 A A271 A A A263 A285 A233 A231 A287 A A275 A A235 A223 A A A237 A239 A225 A A197s 70 A211 A181s 120 A201 A173s A A195 A227 A A151s A A175s A163= 40 A197 A163s A A A173 A165s A131 A141 A165 A133s A121= A133 A121s A111=A111s in H2 O 0 Total pressure difference (Vacuum) p 16 nash_elmo Industries _Series

17 T Selection and ordering information for 60 Hz, 3AC, IP55 Curve no. Motor Rated Order no. Weight approx. Sound pressure Vacuum-relief valve 2) Pressure-relief valve 2) output voltage 4) current level 1) Items x type Items x type hp V A lbs db(a) 2BX2... 2BX2... A B / Y 2.0 B / 1.2 Y 2BH A H A B / Y 1.74 B / 1.0 Y 2BH A H A B / Y 2.0 B / 1.15 Y 2BH A H x 114/142 1 x 115/144 A B / Y 2.6 B / 1.5 Y 2BH A H x 114/142 1 x 115/144 A B / Y 3.75 B / 2.15 Y 2BH H H x 114/142 1 x 115/144 A B / Y 3.6 B / 2.1 Y 2BH A H A B / Y 3.75 B / 2.15 Y 2BH A H x 114/142 1 x 115/144 A B / Y 4.0 B / 2.3 Y 2BH A H x 114/142 1 x 115/144 A B / Y 6.9 B / 4.0 Y 2BH A H x 114/142 1 x 115/144 A B / Y 7.6 B / 4.4 Y 2BH H H x 114/142 1 x 115/144 A B / Y 10.0 B / 5.8 Y 2BH H H x 114/142 1 x 115/144 A B / Y 7.6 B / 4.4 Y 2BH A H A B / Y 4.0 B / 2.3 Y 2BH A H x 114/146 2 x 115/148 A B / Y 6.9 B / 4.0 Y 2BH A H x 114/146 1 x 115/148 A B / Y 7.6 B / 4.4 Y 2BH A H x 114/146 1 x 115/148 A B / Y 10.3 B / 6.0 Y 2BH A H x 114/146 1 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH H H x 114/146 1 x 115/148 A B / Y 17.2 B / 9.9 Y 2BH H H x 114/146 1 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH A H A B / Y 8.8B / 5.1 Y 2BH A H x 114/146 2 x 115/148 A B / Y 10.3 B / 6.5 Y 2BH A H x 114/146 2 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH A H x 114/146 1 x 115/148 A B / Y 16.4 B / 9.5 Y 2BH A H x 114/146 1 x 115/148 A B / Y 10.3 B / 6.0 Y 2BH H H x 114/146 2 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH H H x 114/146 2 x 115/148 A B / Y 18 B / 10.4 Y 2BH H H x 114/146 2 x 115/148 A B / Y 23 B / 13.3 Y 2BH H H x 114/146 1 x 115/148 A B / Y 30 B / 17.3 Y 2BH H H x 114/146 1 x 115/148 A B / Y 16.4 B / 9.5 Y 2BH H x 114/146 3 x 115/148 A B / Y 23 B / 13.3 Y 2BH H x 114/146 3 x 115/148 A B / Y 30 B / 17.3 Y 2BH H x 114/146 2 x 115/148 A B / Y 16.4 B / 9.5 Y 2BH A H x x 115 A B / Y 23 B / 13.3 Y 2BH A H x x 115 A B / Y 30 B / 17.3 Y 2BH A H x x 115 A B / Y 23 B / 13.3 Y 2BH H H x x 115 A B / Y 30 B / 17.3 Y 2BH H H x x 115 A B / Y 50.2 B / 29 Y 2BH H H x x 115 A B / Y 60 B / 34.5 Y 2BH H H x x 115 A B / Y 30.8 B / 17.6 Y 2BH J H x x 153 A B / Y 50.2 B / 29 Y 2BH J H x x 151 A B / Y 33 B / 19,1 Y 2BH A H x x 153 A B / Y 50 B / 29 Y 2BH A H x x 151 A B / Y 68 B / 39 Y 2BH A H x x 115 A B / Y 50 B / 29 Y 2BH H H x x 153 A B / Y 63 B / 36.5 Y 2BH H H x x 153 A B / Y 72 B / 42 Y 2BH H H x x 151 A B / Y 90 B / 52 Y 2BH H H x x 151 A B / Y 33 B / 19.1 Y 2BH A H x x 153 A B / Y 50 B / 29 Y 2BH A H x x 153 A B / Y 68 B / 39 Y 2BH A H x x 151 A B / Y 63 B / 36.5 Y 2BH H 2 6 3) x x 155 A B / Y 72 B / 42 Y 2BH H 3 6 3) x x 155 A B / Y 90 B / 52 Y 2BH H 4 6 3) x x 153 Selection and ordering information for 60 (50) Hz, 1AC, IP55 A111s / 230 / 5.2 / 2.6 2BH A V A121s / 230 / 5.7 / 2.9 2BH A V A133s / / 3.0 2BH A V x 114/142 1 x 115/144 A151s / 10 / 2BH A B A163s / 11.6 / 2BH A B x 114/142 1 x 115/144 A165s / / 8.3 2BH A V x 114/142 1 x 115/144 A173s / / 12 2BH H V x 114/142 1 x 115/144 A181s / 21.5 / 2BH A B A197s / / BH A V x 114/146 1 x 115/148 Details on voltages, footnotes etc. see page 83. nash_elmo Industries _Series 17

18 _Series _200, 60 Hz The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Selection diagram, compressor operation Suction capacity V cfm A351 A381 A321 A383 A353 A331 A341 A385 A333 A343 A355 A345 A335 A347 u_5012k m 3 /h A281 A A261 A191 A151s A181s A161 A151 A231 A193 A271 A221 A163s A163 A233 A263 A223 A197s A211 A195 A173s A165s A181 A225 A283 A273 A235 A265 A227 A201 A171 A A285 A275 A287 A237 A239 A203 A175s A A121= A121s A131 A133s A165 A A133 A111=A111s in H 2 O Total pressure difference (Vacuum) p nash_elmo Industries _Series 18

19 A PV-5012k Please open this page for selection diagram. _Series _200, 60 Hz Selection and ordering information for 60 Hz, 3AC, IP55 Curve no. Motor Order no. Weight Soundpressure valve 2) valve 2) Vacuum-relief Pressure-relief Ratedoutput voltage4) current Available level 1) Items x type Items x type approx. kw V A ex stock kg db(a) 2BX2... 2BX2... A B / Y 2.0 B / 1.2 Y 2BH A H A B / Y 1.74 B / 1.0 Y 2BH A H A B / Y 2.0 B / 1.15 Y 2BH A H x 114/142 1 x 115/144 A B / Y 2.6 B / 1.5 Y 2BH A H x 114/142 1 x 115/144 A B / Y 3.75 B / 2.15 Y 2BH H H x 114/142 1 x 115/144 A B / Y 3.6 B / 2.1 Y 2BH A H A B / Y 3.75 B / 2.15 Y 2BH A H x 114/142 1 x 115/144 A B / Y 4.0 B / 2.3 Y 2BH A H x 114/142 1 x 115/144 A B / Y 6.9 B / 4.0 Y 2BH A H x 114/142 1 x 115/144 A B / Y 7.6 B / 4.4 Y 2BH H H x 114/142 1 x 115/144 A B / Y 10.0 B / 5.8 Y 2BH H H x 114/142 1 x 115/144 A B / Y 7.6 B / 4.4 Y 2BH A H A B / Y 4.0 B / 2.3 Y 2BH A H x 114/146 2 x 115/148 A B / Y 6.9 B / 4.0 Y 2BH A H x 114/146 1 x 115/148 A B / Y 7.6 B / 4.4 Y 2BH A H x 114/146 1 x 115/148 A B / Y 10.3 B / 6.0 Y 2BH A H x 114/146 1 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH H H x 114/146 1 x 115/148 A B 9.9 B 2BH H H x 114/146 1 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH A H A B / Y 8.8B / 5.1 Y 2BH A H x 114/146 2 x 115/148 A B / Y 10.3 B / 6.5 Y 2BH A H x 114/146 2 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH A H x 114/146 1 x 115/148 A B 9.5 B 2BH A H x 114/146 1 x 115/148 A B / Y 10.3 B / 6.0 Y 2BH H H x 114/146 2 x 115/148 A B / Y 12.6 B / 7.3 Y 2BH H H x 114/146 2 x 115/148 A B 10.4 B 2BH H H x 114/146 2 x 115/148 A B 13.3 B 2BH H H x 114/146 1 x 115/148 A B 17.3 B 2BH H H x 114/146 1 x 115/148 A B 9.5 B 2BH H x 114/146 3 x 115/148 A B 13.3 B 2BH H x 114/146 3 x 115/148 A B 17.3 B 2BH H x 114/146 2 x 115/148 A B 9.5 B 2BH A H x x 115 A B 13.3 B 2BH A H x x 115 A B 17.3 B 2BH A H x x 115 A B 13.3 B 2BH H H x x 115 A B 17.3 B 2BH H H x x 115 A B 29 B 2BH H H x x 115 A B 34.5 B 2BH H H x x 115 A B 17.6 B 2BH J H x x 153 A B 29 B 2BH J H x x 151 A B 19.1 B 2BH A H x x 153 A B 29 B 2BH A H x x 151 A B 39 B 2BH A H x x 115 A B 29 B 2BH H H x x 153 A B 36.5 B 2BH H H x x 153 A B 42 B 2BH H H x x 151 A B 52 B 2BH H H x x 151 A B 18.2 B 2BH A H x x 153 A B 29 B 2BH A H x x 153 A B 39 B 2BH A H x x 151 A B 36.5 B 2BH H 2 73) x x 155 A B 42 B 2BH H 3 73) x x 155 A B 52 B 2BH H 4 73) x x 153 Selection and ordering information for 60 (50) Hz, 1AC, IP55 A111s / 230 / 5.2 / 2.6 2BH A V A121s / 230 / 5.7 / 2.9 2BH A V A133s / / 3.0 2BH A V x 114/142 1 x 115/144 A151s / 10 / 2BH A B A163s / 11.6 / 2BH A B x 114/142 1 x 115/144 A165s / / 8.3 2BH A V x 114/142 1 x 115/144 A173s / / 12 2BH H V x 114/142 1 x 115/144 A181s / 21.5 / 2BH A B A197s / / BH A V x 114/146 1 x 115/148 The performance curves are valid for pumping air at 15 C at the inlet flanges with an air pressure of 1,013 mbar and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 25 C. Selection diagram, compressor operation Suction capacity A381 A383 A m 3 /h A m A353 3 /min A A A331 A A333 A355 A347 A A A281 A A A261 A A263 A285 A273 A231 6 A A235 A275 A287 5 A223 A225 A265 A237 4 A A193 A227 A239 3 A197s 150 A211 A181s A195 A A181 A173s A A161 A151s A171 A163s 1,5 A175s 80 A163 A197 A151 A173 A165s 60 1 A165 A121= A131 0,8 40 A121s A133s A141 0,5 20 A ,2 A111=A111s 0 0 mbar Total pressure difference (Pressure) Details on voltages, footnotes etc. see page 82. nash_elmo Industries _Series 17 nash_elmo Industries _Series 18

20 _Series _200e with frequency converter The _200 pumps and compressors with integrated frequency converter (FC) are supplied with a standard speed of 5,000 min -1. A reduction in the speed and thus adaptation to the required duty point is possible 1. manually: by adjusting the setting at the potentiometer 2. automatically: by specifying the target value via the analogue input ( V, ma) 3. automatically: via the digital input The range meets the EMC guidelines because of the radio interference suppression filter (class A) that is installed as standard. Standard protection features: Over-voltage protection Short-circuit protection Overheating protection of converter PTC thermistor for integrated converter, optional for external converter Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC A142e 2.0 2, ,000 2BH HN21 2BH HH26 2FC NE00 A162e 3.0 2, ,000 2BH AN21 2BH AH26 2FC NE00 Selection diagram 2BH vacuum operation 90 cfm 80 A142e 70 Suction capacity V compressor operation u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagram 2BH vacuum operation compressor operation 150 u_6102 cfm The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Suction capacity V 120 A162e in H 2 O (Vacuum) Total pressure difference p (Pressure) 20 nash_elmo Industries _Series

21 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC A174e 5.4 2, ,000 2BH HN41 2BH HH46 2FC NE00 A193e 5.4 2, ,000 2BH AN31 2BH AH36 2FC NE00 A205e 10 2, ,000 2BH HN51 2BH HH56 2FC NE00 Selection diagram 2BH vacuum operation compressor operation Suction capacity V 150 cfm A174e u_ in H 2 O Selection diagram 2BH vacuum operation compressor operation 250 u_6104 cfm Suction capacity V A193e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagram 2BH vacuum operation compressor operation 250 u_6105 cfm Suction capacity V A205e in H 2 O (Vacuum) Total pressure difference p (Pressure) The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). nash_elmo Industries _Series 21

22 _Series _200e with frequency converter Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC A223e , ,000 2BH AN31 2BH AH36 2FC NE00 A233e , ,000 2BH HN31 2BH HH36 2FC NE00 A235e , ,000 2BH HH56 2FC NE00 A264e , ,200 2BH H46 2FC NE00 A265e , ,000 2BH H56 2FC NE00 Selection diagram 2BH vacuum operation 300 cfm compressor operation u_6106 Suction capacity V A223e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation Suction capacity V 350 cfm A233e A235e u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation 500 u_6108 cfm The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Suction capacity V A264e A265e in H 2 O (Vacuum) Total pressure difference p (Pressure) 22 nash_elmo Industries _Series

23 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC A270e 10 2, ,000 2BH AN01 2BH AH06 2FC NE00 A272e , ,000 2BH AH26 2FC NE00 A282e , ,000 2BH HH26 2FC NE00 A284e , ,000 2BH HH46 2FC NE00 A323e , ,000 2BH JH36 2FC NE00 Selection diagrams 2BH vacuum operation compressor operation 600 u_6109 cfm A270e A272e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation 500 u_6110 cfm Suction capacity V Suction capacity V A282e A284e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagram 2BH vacuum operation compressor operation 900 u_6111 cfm 800 Suction capacity V 700 A323e in H 2 O (Vacuum) Total pressure difference p (Pressure) The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). nash_elmo Industries _Series 23

24 _Series _200e with frequency converter Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC A330e , ,200 2BH AH06 2FC NE00 A333e , ,200 2BH AH36 2FC NE00 A341e , ,200 2BH HH16 2FC NE00 A344e , ,200 2BH HH46 2FC NE00 A382e , ,600 2BH H26 2FC NE00 A384e , ,200 2BH H46 2FC NE00 Selection diagrams 2BH vacuum operation Suction capacity V 900 cfm A330e A333e compressor operation u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation 900 u_6113 cfm 800 A341e 700 A344e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation 1800 u_6114 cfm A382e A384e 1500 Suction capacity V The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Suction capacity V in H 2 O (Vacuum) Total pressure difference p (Pressure) 24 nash_elmo Industries _Series

25 Notes nash_elmo Industries _Series 25

26 _400 _400 single and multi-stage _400e with integrated or external frequency converter

27 _400 Unsurpassed at highest differential pressure Our revolutionary _400 blowers can create pressure differences of up to 400 inch H 2 O more than any other gas ring pump! So far, the systems used to reach these differential pressure ranges were much louder and larger or subject to wear. Now the advantages of wear-free operation coupled with a low noise level can also be used in the most demanding applications. The _400 vacuum pumps and compressors can work up to 20,000 hours without maintenance down time. These specialist machines have proven their reliability under the harshest of conditions. Their noise level was already impressively low, but our engineers and designers were able to make them even more quiet. Selection diagrams and tables for _400, pages vacuum and compressor mode, 50 and 60 Hz _400e pumps and compressors with speed control pages and frequency converter Details on voltages, footnotes etc. see page 83

28 _Series _400, 50/60 Hz Vacuum-compressor selection diagram 50 Hz Suction capacity V 100 cfm B in H 2 O (Vacuum) B270= B272 B150= B152= B150s B240 B244 B180s B210 B212 B180=B182 B260= B262 B230= B232 B200= B200s B172 B142=B140s Vacuum-compressor selection diagram 60 Hz 120 cfm 110 Suction capacity V The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). B170= B172s Total pressure difference p B260 B240 B270 B230 B262 B200s B210 B170 B180 B200 B182=B182s B232 B150 B150s B140=B140s B172=B172s B152 B271 B272 B212 B244 (Pressure) u_5317h B282 u_5318g 70 B261 B B241 B B271= B283 B273 B B211 B261 B B241 B263 B181 B245 B245 B211 B181s 20 B231 B201s B171 B233 B181s B171 B201= B151 B183 B213 B213 B181 B233 B173s B201s B173s 10 B151s B201 B141s B141s B151s B151 B141 B153 B183 B153 B173 B141 B in H2 O (Vacuum) Total pressure difference p (Pressure) 28 nash_elmo Industries _Series

29 Selection and ordering information for 50 Hz, 3AC, IP55 Curve no. Motor Order no. Rated output voltage 4) current hp V A Weight approx. lbs Sound pressure level 1) db(a) Vacuum-relief valve 2) Items x Typ 2BX2... Pressure-relief valve 2) Items x Typ 2BX2... B B / Y 2.8 B / 1.6 Y 2BH A H x 110/141 1 x 111/143 B B / Y 4 B / 2.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 7.5 B / 4.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 2.8 B / 1.6 Y 2BH A H x 110/141 1 x 111/143 B B / Y 4 B / 2.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 5.4 B / 3.1 Y 2BH A H x 110/141 1 x 111/143 B B / Y 7.5 B / 4.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 5.4 B / 3.1 Y 2BH A H x 110/141 1 x 111/143 B B / Y 7.5 B / 4.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 13 B / 7.5 Y 2BH A H x 110/141 1 x 111/143 B B / Y 7.5 B / 4.3 Y 2BH A H x 110/141 1 x 111/143 B B / Y 11.4 B / 6.6 Y 2BH A H x 110/141 1 x 111/143 B B / Y 11.4 B / 6.6 Y 2BH A H x 110/141 1 x 111/143 B B / Y 15.5 B / 9 Y 2BH A H x 110/141 1 x 111/143 B B / Y 11.4 B / 6.6 Y 2BH A H x 110/141 1 x 111/143 B B / Y 13 B / 7.5 Y 2BH A H x 110/141 1 x 111/143 B B / Y 13 B / 7.5 Y 2BH A H x 110/141 1 x 111/143 B B / Y 21.5 B / 12.5 Y 2BH A H x 110/141 1 x 111/143 B B / Y 27.5 B / 16 Y 2BH A H x 110/141 1 x 111/143 Selection and ordering information for 60 Hz, 3AC, IP 55 B B / Y 3 B / 1.7 Y 2BH A H x 114/142 1 x 115/144 B B / Y 4 B / 2.3 Y 2BH A H x 114/142 1 x 115/144 B B / Y 7.6 B / 4.4 Y 2BH A H x 114/142 1 x 115/144 B B / Y 3 B / 1.7 Y 2BH A H x 114/142 1 x 115/144 B B / Y 4 B / 2.3 Y 2BH A H x 114/142 1 x 115/144 B B / Y 5.4 B / 3.1 Y 2BH A H x 114/142 1 x 115/144 B B / Y 7.6 B / 4.4 Y 2BH A H x 114/142 1 x 115/144 B B / Y 5.4 B / 3.1 Y 2BH A H x 114/142 1 x 115/144 B B / Y 7.6 B / 4.4 Y 2BH A H x 114/142 1 x 115/144 B B / Y 13.8 B / 8 Y 2BH A H x 114/142 1 x 115/144 B B / Y 7.6 B / 4.4 Y 2BH A H x 114/142 1 x 115/144 B B / Y 11.2 B / 6.5 Y 2BH A H x 114/142 1 x 115/144 B B / Y 11.2 B / 6.5 Y 2BH A H x 114/142 1 x 115/144 B B / Y 16.5 B / 9.5 Y 2BH A H x 114/142 1 x 115/144 B B / Y 11.2 B / 6.5 Y 2BH A H x 114/142 1 x 115/144 B B / Y 14.2 B / 8.2 Y 2BH A H x 114/142 1 x 115/144 B B / Y 14.2 B / 8.2 Y 2BH A H x 114/142 1 x 115/144 B B / Y 21 B / 12 Y 2BH A H x 114/142 1 x 115/144 B B / Y 27.5 B / 16 Y 2BH A H x 114/142 1 x 115/144 Selection and ordering information for 50 Hz, 1AC, IP 55 B140s / / 3.1 2BH A V B150s / / 9.7 2BH A V B172s / / 7.6 2BH A V B180s / / 9.7 2BH A V B200s / / 8.0 2BH A V Selection and ordering information for 60 Hz, 1AC, IP 55 B141s / / 7.1 2BH A V B151s / / BH A V B173s / / 9 2BH A V B181s / / BH A V B201s / 230/ 20 / 10 2BH A V Details on voltages, footnotes etc. see page 83. nash_elmo Industries _Series 29

30 _Series _400e with frequency converter The _400 pumps and compressors with integrated frequency converter (FC) are supplied with a standard speed of 5,000 min -1. A reduction in the speed and thus adaptation to the required duty point is possible 1. manually: by adjusting the setting at the potentiometer 2. automatically: by specifying the target value via the analogue input ( V, ma) 3. automatically: via the digital input The range meets the EMC guidelines because of the radio interference suppression filter (class A) that is installed as standard. Standard protection features: Over-voltage protection Short-circuit protection Overheating protection of converter PTC thermistor for integrated converter, optional for external converter B141e 2 2, ,000 2BH AN11-7 2BH AH16-7 2FC NE00 74 B145e 4 2, ,000 2BH AN51-7 2BH AH56-7 2FC NE00 74 B155e 4 2, ,000 2BH AN51-7 2BH AH56-7 2FC NE00 74 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC Soundpressure level 1) db(a) Selection diagrams 2BH vacuum operation 50 cfm compressor operation u_6130 Suction capacity V B141e B145e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagram 2BH vacuum operation compressor operation 50 u_6131 cfm The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Suction capacity V 40 A155e in H 2 O (Vacuum) Total pressure difference p (Pressure) 30 nash_elmo Industries _Series

31 B172e 2 2, ,000 2BH AN21-7 2BH AH26-7 2FC NE00 76 B176e 5.4 2, ,000 2BH AN61-7 2BH AH66-7 2FC NE00 76 B185e 4 2, ,000 2BH AN51-7 2BH AH56-7 2FC NE00 76 B188e 7.4 2, ,000 2BH AN81-7 2BH AH86-7 2FC NE00 76 B201e 3 2, ,000 2BH AN11-7 2BH AH16-7 2FC NE00 76 B205e 7.4 2, ,000 2BH AN51-7 2BH AH56-7 2FC NE00 76 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC Soundpressure level 1) db(a) Selection diagrams 2BH vacuum operation 70 cfm 60 compressor operation u_6132 Suction capacity V B172e B176e in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation 70 cfm 60 B185e=188e 50 Suction capacity V compressor operation B185e B188e u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation compressor operation 90 u_6134 cfm 80 Suction capacity V B201e B205e in H 2 O (Vacuum) Total pressure difference p (Pressure) The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). nash_elmo Industries _Series 31

32 _Series _400e with frequency converter B212e 4 2, ,000 2BH AN21-7 2BH AH26-7 2FC NE00 76 B215e 7.4 2, ,000 2BH AN51-7 2BH AH56-7 2FC NE00 76 B232e 5.4 2, ,000 2BH AN21-8 2BH AH26-8 2FC NE00 78 B236e 10 2, ,000 2BH AN61-8 2BH AH66-8 2FC NE00 78 B247e 10 2, ,000 2BH AN71-8 2BH AH76-8 2FC NE00 78 B248e , ,000 BH7520-2BH AH86-8 2FC NE00 78 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC Soundpressure level 1) db(a) Selection diagrams 2BH vacuum operation Suction capacity V 90 cfm B212e B215e compressor operation u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation 120 cfm B232e=B236e 100 compressor operation B232e B236e u_6136 Suction capacity V in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation 120 cfm B247e=B248e 100 compressor operation B247e B248e u_6137 The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). Suction capacity V in H 2 O (Vacuum) Total pressure difference p (Pressure) 32 nash_elmo Industries _Series

33 B263e 7.4 2, ,000 2BH AN31-8 2BH AH36-8 2FC NE00 77 B265e , ,000 BH7610-2BH AH56-8 2FC NE00 77 B273e 7.4 2, ,000 2BH AN31-8 2BH AH36-8 2FC NE00 80 B275e , ,000 BH7610-2BH AH56-8 2FC NE00 80 B285e , ,000 BH7610-2BH AH56-8 2FC NE00 80 B286e , ,000 BH7610-2BH AH66-8 2FC NE00 80 Selection and ordering information for 3 AC, Hz, V, IP55 Curve no. Rated performance Speed range Order no. as ring compressor as ring compressor P (in hp) min -1 with integrated FC for external FC external FC Soundpressure level 1) db(a) Selection diagrams 2BH vacuum operation Suction capacity V 160 cfm 140 B263e=B265e compressor operation B263e B265e u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation 180 cfm 150 B273e B275e 120 Suction capacity V compressor operation u_ in H 2 O (Vacuum) Total pressure difference p (Pressure) Selection diagrams 2BH vacuum operation 180 cfm B285e=B286e 150 compressor operation B285e B286e u_6140 Suction capacity V in H 2 O (Vacuum) Total pressure difference p (Pressure) The performance curves are valid for pumping air at 60 F (15 C) at the inlet flanges with an air pressure of 29,9 in Hg abs. (1,013 mbar) and a tolerance of ±10%. The total pressure differences are valid up to an intake and ambient temperature of 77 F (25 C). nash_elmo Industries _Series 33

34 Acces

35 sories Accessories for _Series 2BH1 and 2BH7 Filters, sound protection hoods, flanges, valves... Selection and ordering details accessories pages for _200 and _400

36 Accessories for pumps & compressors _Series 2BH1 / 2BH7 Selection and ordering data For type Order no. Weight approx. lbs Example In line filter for vacuum pumps 1) - incl. mounting kit for fixed installation: Paper filter insert gasket, threaded flange, double pipe nipple, 2BH1 1. / 3. 2BX pipe elbow and through-filter 2BH / / / BX BH7 3 / 7 4/ 7 5/ 7 6 2BH / / / BX Polyester filter insert 2BH1 1./ 3. 2BX Particle size: Paper: 7-9 µm Polyester: 3 µm - incl. gasket, hose flange, double reduction nipple Paper filter insert through-filter and hose clips, but excluding the 2BH1 2. / 2BX connecting hose between filter and 2BH / / vacuum pump 2BH1 49 / 2BH1 5./ BH / BX BH1 41 Polyester filter insert 2BH1 2 2BH / / BX BH1 49 / 2BH1 5/ 1 6 2BH / BX BH incl. reduction nipple, through-filter and hose Paper filter insert clips excl. connecting hose between filter and 2BH1 8. 2BX vacuum pump Polyester filter insert 2BH1 8. 2BX incl. connecting flange, gasket, adapting nipple, Paper filter insert through-filter, hose clips and connecting hose 2BH1 90/ 91 2BX between filter and vacuum pump 2BH1 94 2BX Polyester filter insert 2BH1 90/ 91 2BX BH1 94 2BX Example Replacement filter elements for in line filters Paper filter insert Order Example: EWN: BX BX2 061/ 063/ BX2 065/ Polyester filter insert 2BX BX4 081/ 083/ BX4 085/ for suction filters Paper filter insert Order Example: EWN: BX BX2 101/ 102/ 107/ BX2 103/ Polyester filter insert 2BX BX4 061/ 063/ BX4 065/ BX4 085/ ) All filters are suitable only for separation with dry air and cannot be used for liquids. Installation must be made to ensure that no water can enter the filter. 36 nash_elmo Industries _Series

37 Selection and ordering data For type Order no. Weight approx. lbs Suction filter for compressors 1) - incl. mounting kit: gasket, threaded flange pipe Paper filter insert elbow and, according to _Series type, spigot, 2BH1 1. / 3. 2BX adaptor flange, nipple and reducing coupling Polyester filter insert 2BH1 1. / 3. 2BX Paper filter insert 2BH1 2. / 2BX BH / / BH1 49 Polyester filter insert 2BH1 2. / 2BX BH / / BH1 49 Example Particle size: Paper: 7-9 µm Polyester: 3 µm Paper filter insert 2BH / BX BH1 41 Polyester filter insert 2BH / BX BH1 41 Paper filter insert 2BH1 5./ 60/ 61/ 69 2BX Polyester filter insert 2BH1 5. / 60 / 61 / 69 2BX Paper filter insert 2BH1 64 2BX Polyester filter insert 2BH1 64 2BX Paper filter insert 2BH1 8. 2BX Polyester filter insert 2BH1 8. 2BX Paper filter insert 2BH / - 2. / BX BH7 3. / 4. Polyester filter insert 2BH / - 2./ BX BH7 3./ 4. Paper filter insert 2BH7 5./ 6. 2BH / - 6./ - 7./ BX Paper filter insert 2BH7 5./ 6. 2BX Paper filter insert 2BH N1./ -..N2./ -..N4. 2BX Paper filter insert 2BH N5. / -..N6. / -..N7. / -..N8. 2BX Paper filter insert 2BH N.. 2BX BH N.. 2BH N.. 2BH N.. nash_elmo Industries _Series 37

38 Accessories for pumps & compressors _Series 2BH1 / 2BH7 Selection and ordering data For type Order no. Weight approx. lbs Example Suction-side through-filter 1) - incl. connecting flange, gasket, adapting nipple, Paper filter insert through-filter, hose clips and connecting hose 2BH1 90/ 91 2BX between filter and vacuum pump 2BH1 94 2BX Polyester filter insert 2BH1 90/ 91 2BX BH1 94 2BX Example Fixing clamp - for floor mounting (1 set = 4 retaining 2BH BX washers, 4 fixing screws M 12 x 20 and 5 clamping devices) Example 90 elbow - incl. gasket and screws 2BH BX ) 2.0 2BH BX ) 3.1 2BH1 510/ BX ) 5.3 2BH BX ) 13.7 Example 1 set of feet - for vertical mounting on the end-cover 2BH (1 set = 3 pieces) 2BH1 1./ 3./ 4. 2BX BH1 5. 2BX BH1 6. 2BX BH1 8. 2BX BH1 90./ 91. 2BX BH7 2. 2BX BH7 3./ 4. 2BX BH7 5./ 6. 2BX for horizontal mounting on the feet 2BH1 1./ 2./ 3./ 4. 2BX (1 set = 4 pieces) 2BH1 5. 2BX BH1 6. 2BX BH1 8. 2BX BH1 90./ 91. 2BX ) All filters are suitable only for separation with dry air and cannot be used for liquids. Installation must be made to ensure that no water can enter the filter. 2) If you wish to order this together with the pump, please add a "Z" to the order number of the pump and the additional information "C21" as follows in this example: 2BH HH26-Z C21 38 nash_elmo Industries _Series

39 Selection and ordering data For type Order no. 1) Dimensions inch Width Height Length Weight approx. lbs Sound protection hoods for _200 For applications in noise-sensitive areas we have designed a special sound protection hood for the _200. These hoods offer a reduction in sound pressure levels audible for the human ear of up to 10 db(a). Tonal peaks that are especially unpleasant can be lowered by up to 20 db. They can be installed both inside and outside. We also supply the sound protection hood already integrated with the compressor or pump. 2) Advantages at a glance: Reduction of sound pressure levels of up to 10 db (A) The tonal peaks that are least pleasant can be considerably reduced Easy to install Weather resistent (for use outdoors) Maintenance-free Can be supplied with compressor Available at short notice We'll be happy to supply more details. Call us if you want to know more. 1) Order number of the sound protection hood for separate delivery 2) "If you wish to order this together with the pump, please add a "Z" to the order number of the pump and the additional information "Z22" as follows in this example: 2BH HH26-Z Z22 2BH BX BH BX BH BX BH BX BH / BX BH / BX BH BX BH / BX BH / BX BH BX BH BX BH / BX BH BX BH BX BH BX BH BX BH BX BH BX BH / BX BH BX BH /-7..2./ BX BH / BX BH / BX BH BX BH / BX BH BX BH / BX BH BX BH /-7..2./ BX BH /-7..2./ BX BH BX BH BX BH BX4 349 Example nash_elmo Industries _Series 39

40 Accessories for pumps & compressors _Series 2BH1 / 2BH7 Selection and ordering data For type Silencing Order no. Ø Weight approx. lbs Example Example Additional silencer - incl. gasket, hose flange, hose clip, 2BH1 20 4dB 2BX and screws 2BH1 10 / 30 6dB 2BX BH1 31 5dB The silencing is measured with average 2BH / / dB 2BX throttling and hose connected to the 2BH1 49 4dB suction side vacuum pump (or to the 2BH / dB 2BX discharge side of the compressor) in an 2BH dB echochamber according to DIN BH1 50 6dB 2BX part 2 2BH1 51 5dB 2BH1 60 7dB 2BX BH161/ 2BH1 64 6dB 2BH1 8 8dB 2BX BH1 81/ 2BH1 84 7dB 2BH1 90 3dB 2BX BH1 91 3dB 2BH1 94 3dB 2BX BH / / dB 2BX BH7 3/ 7 4/ 7 5/ 7 6 2BH / / / dB 2BX Threaded flange - incl. gasket and screws 2BH1 1./ 3. 2BX / BH1 2. 2BX / BH / / / 2BH1 49 2BH / / 2BH1 41 2BX / BH1 5./ BX NPT conical 2BH1 5./ 16. 2BX4 041 NPT BH1 90/ 91 2BX NPT conical 2BH1 90/ 91 2BX4 042 NPT BH1 94 2BX Example NPT conical 2BH1 94 2BX4 043 NPT BH / / BX / BH7 3/ 7 4/ 7 5/ 7 6 2BH BX / Hose flange - incl. gasket and screws 2BH1 2. 2BX BH / / BH1 49./ 2BH1 5. 2BH1 1./ 3. 2BX BH / / 2BH1 41 2BX BH1 6. 2BX BH1 8. 2BX BH1 90./ 91. 2BX BH BX BH / / BX BH7 3/ 7 4/ 7 5/ 7 6 2BH / / / BX nash_elmo Industries _Series

41 Selection and ordering data For type Order no. Weight approx. lbs Vacuum relief valve - suction side 1) - with adaptor, gasket and screws for 50 Hz operation: 2BH1 3./ BX BH1 5./ BX BH / / BX BH7 3./ 7 4. /7 5./ BH BX for 60 Hz operation: 2BH1 3. / 14. 2BX BH1 5. / 16. 2BX BH / / BX BH7 3/ 7 4/ 7 5/ 7 6 2BH BX Pressure relief valve - discharge side 1) - with adaptor, gasket and screws for 50 Hz operation: 2BH1 3./ BX BH1 5./ BX BH / / BX BH7 3/ 7 4/ 7 5/ 7 6 2BH BX for 60 Hz operation: 2BH1 3. / 14. 2BX BH1 5. / 16. 2BX BH / / BX BH7 3./ 7 4./ 7 5./ BH BX Loose vacuum relief valve - suction side 1) for pipeline mounting for 50 Hz operation: 2BH1 3. to 2BH1 8. 2BX BH / BH / / BH BH BH BX BH BH / BH / BX BH7 2BX for 60 Hz operation: 2BH1 3 to 2BH1 6 2BX BH1 80 / 81 2BH BH / BH BH BX BH BH BX BH BH BH / BH / BH BX BH7 2BX BX BX2 15. Example Example Example Example 1) For the required quantity see pages 13, 17 and 29. The suffix Z must be added to the Order No., and the Order No. of the machine must be given Example: 2BX2 110-Z MLFB=2BH AH06 nash_elmo Industries _Series 41

42 Accessories for pumps & compressors _Series 2BH1 / 2BH7 Selection and ordering data For type Order no. Weight approx. lbs Example 2BX2 11. Loose pressure relief valve - discharge side 1) for pipeline mounting for 50 Hz operation: 2BH1 3 to 2BH1 6 2BX BH1 80 / 81 2BH BH / BH / BH BH BX BH BH / BH / BH / / BX BH7 2BX Example 2BX2 15. for 60 Hz operation: 2BH1 3 to 2BH1 6 2BX BH1 80 / 81 2BH BH BX BH BH / BH BH BX BH BH / BH / BH BH / BX BH7 2BX Selection and ordering data Solenoid valves (incl. adaptor, if necessary for mounting) Supply voltage / Rated current For type Order no. Weight approx. kg Example Changeover valve Single spool for changeover from 24 V DC 2BH BX MA0 5.5 vacuum to pressure operation 1.5 A 2BH BX MM BH Load factor: 100 % 2BH BX ME0 5.5 Operating time: 0.35 s Release time: 0.4 s 2BH1 31. to 2BH1 91. on request 230 V AC 2BH BX MA /60 Hz 2BH BX MM A 2BH BH BX ME1 5.5 _Serie PV-5150 _Serie PV-5150 _Serie PV BH1 31. to 2BH1 91. on request Double spool for change over 24 V DC 2BH BX MB0 5.5 from / to vacuum. pressure or 0.8 A 2BH BX MD0 5.5 idling operation 2BH1 31. to 2BH1 91. on request Pressure Idle Vacuum Load factor: 100 % Operating time: 0.35 s 230 V AC 2BH BX MB1 5.5 Release time: 0.4 s 50/60 Hz 2BH BX MD A 2BH1 31. to 2BH1 91. on request 42 nash_elmo Industries _Series

43 Selection and ordering data Solenoid valves (incl. adaptor, if necessary for mounting) Supply voltage / Rated current For type Order no. Weight approx. lbs Changeover valve - for changeover from vacuum 24 V DC 2BH / 1. 2BX ML to pressure operation 1.0 A 2BH BH / 3. 2BX ML Load factor: 100 % 2BH Operating time: 0.35 s Release time: 0.4 s 2BH / 1./ 2. 2BX ML BH BX MP BH BX MR BH / 2. 2BX ML Example 2BH1 31. to 2BH1 91. on request 230 V AC 2BH / 1. 2BX ML /60 Hz 2BH A 2BH / 3. 2BX ML BH BH / 1./ 2. 2BX ML _Serie PV-5021 _Serie PV BH BX MP BH BX MR BH / 2. 2BX ML without power with power _Serie PV-5150 _Serie PV-5150 _Serie _Serie PV-5155a PV-5156a 2BH1 31. to 2BH1 91. on request - for changeover from vacuum 24 V DC 2BH7.1. 2BX MC0 6.2 to pressure operation 1.0 A Example Load factor: 100 % Operating time: 0.35 s Release time: 0.4 s 230 V AC 2BH7.1. 2BX MC /60 Hz 0.13 A - for changeover from vacuum 24 V DC 2BH1 80/ 81 on request to pressure operation o.r. 2BH1 90/ 91 Load factor: 100 % Operating time: 0.35 s Release time: 0.4 s 230 V AC 2BH1 80/ 81 on request 50/60 Hz 2BH1 90/ 91 o.r. Vacuum with power Pressure without power Switch-over valve - to switch between two different 24 V DC 2BH1 5/ 1 6 2BX MJ pressure/vacuum pipelines with the 2.4 A same flow direction or flow interruption with one conveyor pipeline Load factor: 100 % 230 V AC 2BH1 5/ 1 6 2BX MJ Operating time: 0.35 s 50/60 Hz Release time: 0.4 s 0.5 A Example Pipe1 Proces Pipe2 with power Pipe1 Process Pipe2 without power nash_elmo Industries _Series 43

44 Dimens

45 ions Dimension drawings for _200 Pages _200e Pages 54 _400 Pages _400e Pages 58 Accessories Pages 59-63

46 Dimensions Dimensions for 2BH1 10.,2BH1 20., 2BH1 30., 2BH1 40., 2BH1 49. (inch) 2BH BH1 10. / 2BH1 30. / 2BH1 40. / 2BH1 49. A V V' V 1 V 1 ' J V V 1 32 V' V 1 ' A V V' V 1 V 1 ' J Y x Z V V 1 32 V' V 1 ' B U H B U X-3 x 120 H O R O R S P C D E Q N K M L F PV-5058b S P C D E Q N K M L F PV-5059c Y x Z 120 X Hole pattern, cover 120 Type Phases Curve no. A B C D E F H J K L M N O P Q Ø R 2BH AA0. 1 ~ A120s / 2 (.59 deep) AB0. A121s AH0. 3 ~ A120/ BH A.1. 1 ~ A132s/133s / 4 (.59 deep) BH A.0. und 2BH A.0. 3 ~ A130/ A.1. A132/ BH A.1. 1 ~ A162s/163s / 2 (.59 deep) A.2. A164s/165s 2BH A.0. 3 ~ A160/ A.1. A162/ A.2. A164/165 2BH AA1. 1 ~ A150s AB1. A151s - 7AH1. 3 ~ A150/ Type Phases Curve no. S U V (1 ~) V (1 ~) V 1 (3 ~) V 1 (3 ~) Y x Z X-holes Ø X 2BH AA0. 1 ~ A120s 0.10 M 6 x 19 M 16 x 1.5 M 25 x 1.5-2AB0. A121s Pg 11-7AH0. 3 ~ A120/121 M 25 x 1.5 M 16 x 1.5 2BH A.1. 1 ~ A132s/133s M 6 x 17 M 16 x 1.5 M 25 x 1.5 M 6 x 15 0 /120 /240 Ø BH A.0. und M 25 x 1.5 M 16 x 1.5 2BH A.0. 3 ~ A130/131-7A.1. A132/133 2BH A.1. 1 ~ A162s/163s 0.12 M 6 x 19 M 16 x 1.5 M 25 x 1.5 Ø A.2. A164s/165s M 25 x 1.5 M 16 x 1.5 2BH A.0. 3 ~ A160/161-7A.1. A162/163-7A.2. A164/165 2BH AA1. 1 ~ A150s M 16 x 1.5 M 25 x 1.5-7AB1. A151s - 7AH1. 3 ~ A150/151 M 25 x 1.5 M 16 x nash_elmo Industries _Series

47 Dimensions for 2BH1 31., 2BH1 41. (inch) 2BH1 31. / 2BH1 41. B A V V' V 1 V 1 ' A' J Y x Z X-3 x 120 α α V V 1 V' V 1 ' Y x Z X 60 U H' T Q H Hole pattern, cover A A' Yx Z V / V 1 V / V' V 1 / V 1 ' O O P Q C D E R S N K M L F PV-5060c Type Phases Curve no. A A B C D E F H H J K L M N O P Q 2BH H.2. 3 ~ A140/ / 4 (.59 deep) BH H.3. 3 ~ A170/ / 2 (.59 deep) H.4. A172/173 Type Phases Curve no. Ø R S T U V (1 ~) V (1 ~) V 1 (3 ~) V 1 (3 ~) a Ø X Y x Z X-holes 2BH H.2. 3 ~ A140/ M 6 x 17 M 25 x 1,5 M 16 x 1, M 6 x /171 /291 2BH H.3. 3 ~ A170/ M 6 x 19 M 25 x 1,5 M 16 x 1, M 6 x 15-7H.4. A172/173 2BH1 31. / 2BH1 41. B U J T α α Q H' ØX-3 x 120 T ' V' / V 1 ' H 120 Y xz Ø X Hole pattern, cover P Q C D E Ø R S N K M L F Type Phases Curve no. A A B C D E F H H J K L M N O P 2BH H.2. -Z 3 ~ A140/ _x0.6 2BH H.3. -Z 1 ~ /3 ~ A170/171/171s _x0.6-7H.4. -Z 1 ~ /3 ~ A172/173/172s/173s _x0.6 Type Phases Curve no. Q Ø R S T T U V / V 1 V / V 1 α Ø X Y x Z X-holes 2BH H.2. 3 ~ A140/ M 6 x 0.7 M 25 x 1,5 M 16 x 1, M 6 x /171 /291 2BH H.3. 3 ~ A170/ M 6 x 0.8 M 16 x 1,5 M 25 x 1, M 6 x /171 /291-7H.4. A172/ M 6 x 0.8 M 25 x 1,5 M 16 x 1, M 6 x /171 /291 Z = C 21, outlet elbow nash_elmo Industries _Series 47

48 Dimensions Dimensions for 2BH1 50., 2BH1 59., 2BH1 60., 2BH1 69. (inch) 2BH1 50. / 2BH BH1 60. / 2BH1 69. A Y x Z V V 1 W V' V 1 ' B V V' V 1 V 1 ' J U Ø X-3 x 120 H Y x Z ØX 120 Hole pattern, cover O ØR 120 S P C D E Q N K M L F PV-5061c Type Phases Curve no. A B C D E F H J K L M N O P Q Ø R 2BH A ~ A192s/193s A.2. A196s/197s BH A.0. 3 ~ A190/ A.1. A192/193-7A.2. A194/ A.3. A196/197 2BH AA2. 1 ~ A180s AB2. A181s - 7AE1. 3 ~ A AH2. A BH A.0. 3 ~ A A.1. A222/223-7A.2. A224/ A.3. A226/ BH A.1. A A.2. A210/ Type Phases Curve no. S U V (1 ~) V (1 ~) V 1 (3 ~) V 1 (3 ~) Ø X Y x Z X-holes W 2BH A.1. 1 ~ A192s/193s 0.16 M 8 x 17 M 16 x 1.5 M 25 x M 8 x 20 0 /120 / A.2. A196s/197s 2BH A.0. 3 ~ A190/191 M 25 x 1.5 M 16 x 1.5-7A.1. A192/193-7A.2. A194/195-7A.3. A196/197 2BH AA2. 1 ~ A180s M 16 x 1.5 M 25 x 1.5-7AB2. A181s - 7AE1. 3 ~ A180 M 25 x 1.5 M 16 x 1.5-7AH2. A181 2BH A.0. 3 ~ A M 10 x 20-7A.1. A222/223-7A.2. A224/225 M 32 x 1.5 M 32 x 1.5 M 32 x 1.5 M 32 x A.3. A226/227 2BH A.1. 3 ~ A210 M 25 x 1.5 M 16 x A.2. A210/211 M 32 x 1.5 M 32 x 1.5 M 32 x 1.5 M 32 x nash_elmo Industries _Series

49 Dimensions for 2BH1 51., 2BH1 61., 2BH1 64. (inch) 2BH BH BH A A' Y xz V / V 1 W V' / V 1 ' O C C B V / V' U V 1 / V 1 ' α J H' α Q ØX-3 x 120 T H Hole pattern, cover Y xz 51,5 M PV-5097 O C P Q D E Ø R S T PV-5096 T N K M L F 120 Ø X 120 Type Phases Curve no. A A B C C D E F H H J K L M N O 2BH H.1.-Z 3 ~ A200/ BH H.5.-Z 3~ A202/ BH H.1.-Z 3~ A230/ BH H.2.-Z 3~ A232/ BH H.3.-Z 3~ A234/ BH H.4.-Z 3~ A236/ BH H.5.-Z 3~ A238/ Type Phases Curve no. Ø P Q Ø R S T T U V/V 1 V /V 1 α Ø X Y x Z X-holes W 2BH H.4.-Z 3~ A200/ M8x0.67 M32x1.5 M32x M8x /171 / BH H.5.-Z 3~ A202/ M8x0.67 M32x1.5 M32x M8x /171 / BH H.1.-Z 3~ A230/ M8x0.67 M25x1.5 M16x M10x /171 / BH H.2.-Z 3~ A232/ M8x0.67 M25x1.5 M16x M10x /171 / BH H.3.-Z 3~ A234/ M8x0.67 M32x1.5 M32x M10x /171 / BH H.4.-Z 3~ A236/ M8x0.67 M32x1.5 M32x M10x /171 / BH H.5.-Z 3~ A238/ M8x0.67 M32x1.5 M32x M10x /171 / Z = C 21, outlet elbow nash_elmo Industries _Series 49

50 Dimensions Dimensions for 2BH1 51., 2BH1 61., 2BH1 64. (inch) 2BH A Y x Z F 42 V O V V Y x Z 120 B U X 120 O J O 2BH BH A A' Y x Z V V 1 W V' V 1 ' C 209 M PV-5063a B O V U V' C P Q D E V 1 R V 1 ' S J H' X-3 x 120 PV-5062d 23,5 23,5 Q T N K M L F 51 5 H 120 Y x Z X 51,5 120 Hole pattern, cover Type Curve no. A A B C D E F H H J K L M N O Ø P Q 2BH H.4. A200/ H.5. A202/ BH H.1. A230/ H.2. A232/ H.3. A234/ H.4. A236/ H.5. A238/239 Type Curve no. Ø R S T U V V V 1 V 1 Ø X Y x Z X-holes W 2BH H.4. A200/ M 8 x 17 4 x M 32 x M 8 x /171.5 / H.5. A202/203 2BH H.1. A230/ M 8 x 17 M 25 x 1.5 M 16 x M 10 x H.2. A232/ H.3. A234/235 4 x M 32 x 1.5-7H.4. A236/237-7H.5. A238/239 2BH BH Hole pattern, cover 209 C' H X-3 x 120 M PV-5065a P Q C D E R S P V-5064d N K M L Type Curve no. A B C C D E F H J K L M N 2BH A260/ A262/ A264/265 Type Curve no. O Ø P Q Ø R S U V Ø X Y x Z X-holes 2BH A260/ M 8 x 17 4 x M 32 x M 10 x 20 0 /120 / A262/ A264/ nash_elmo Industries _Series

51 Dimensions for 2BH1 80., 2BH1 81., 2BH1 84. (inch) 2BH1 80. J A M' Y x Z N F' 2BH1 81. C 1 C 2 J Y xz N' F M' B O B ØX - 3x120 V W H O 1 P H O 2 B B ØX - 3x120 V W P C D E R S M Y xz K L F 15 X 120 PV-5066b A' D E A R N Y xz K L F' X S 120 PV-5067a Hole pattern, cover 120 Hole pattern, cover 120 Type Curve no. A A B B C C1 C2 D E F F H J K L M M N 2BH A.0. A270/ A.1. A272/ A.2. A274/275 2BH H.1. A280/ H.2. A282/283-7H.3. A284/ H.4. A286/287 Type Curve no. N O O 1 O 2 Ø P Ø R S V W Ø X Y x Z X-holes 2BH A.0. A270/ / 2 F-NPT x Pg M 12 x /135 /255-7A.1. A272/273-7A.2. A274/275 2BH H.1. A280/ / 2 F-NPT 4 x M 52 x /120 /240-7H.2. A282/283-7H.3. A284/ x M 40 x H.4. A286/287 2BH A C F' F O Y x Z B P Y x Z 75 H Ø X - 3x120 V W 120 X 120 Hole pattern, cover S R D E J N K L P V b Type Curve no. A B C D E F F H J K L N 2BH J.2. A320/ J.3. A322/ Type Curve no. O Ø P Ø R S V W Ø X Y x Z X-holes 2BH J.2. A320/ / 2 F-NPT x M 32 x M 12 x /195 /315-7J.3. A322/323 4 x M 40 x nash_elmo Industries _Series 51

52 B B H J O A V A' U Q Q 26, H' YxZ X-3x120 F W V P C D E C' ØR A V P-509b V O ' Dimensions Dimensions for 2BH1 91., 2BH1 90. (inch) 2BH1 91. T Ø PV-5099 Yx Z ØX 51 Hole pattern, cover S N T' F'' F' K M Type Phases Curve no. A A B B C C D E F F F H H J K M N 2BH H.1.-Z 3~ A340/ BH H.2.-Z 3~ A342/ BH H.3.-Z 3~ A344/ Type Phases Curve no. O Ø P Q Ø R S T U V W Ø X Y x Z X-holes 2BH H.1.-Z 3~ A340/ M 12 x 1.2 M40 x M 12 x /171 /291 2BH H.2.-Z 3~ A342/ M 12 x 1.2 M40 x M 12 x /171 /291 2BH H.3.-Z 3~ A344/ M 12 x 1.2 M40 x M 12 x /171 /291 Z = C 21, outlet elbow 2BH1 90. / B 1 F W B H Q 6,5 Ø - 3 x 20 X 1 1 Hole pattern, cover P C D E C' R S N F' K F' M Type Curve no. A B B1 C C D E F F F H J K M N 2BH1 90. und 2BH A.0. A330/331/350/ A.1. A332/333/352/ A.3. A334/335/354/355 Type Curve no. O Ø P Q Ø R S U V W Ø X Y x Z X-holes 2BH1 90. und 2BH A.0. A330/331/350/ M 12 x 30 4 x M32 x M 12 x 30 0 /120 /240-7A.1. A332/333/352/353 4 x M40 x A.3. A334/335/354/ nash_elmo Industries _Series

53 Dimensions for 2BH1 91., 2BH1 943 (inch) 2BH1 91. B 1 B H J 26.5 U Q A V A' H' Y x Z Ø X - 3x120 Q F W V PV-5070b 120 Y x Z X Hole pattern, cover O P C D E C' ØR S N T F' F'' K M Type Curve no. A A B B1 C C D E F F F H H J K M 2BH H.1. A340/ H.2. A342/343-7H.3. A344/345 Type Curve no. N O Ø P Q Ø R S T U V W Ø X Y x Z X-holes 2BH H.1. A340/ M 12 x 30 4 x M40 x M 12 x /171.4 / H.2. A342/343-7H.3. A344/345 P 2BH X F" View X V F Foot Foot 2 B W 75 M8 M8 F' 3.41 D Y Z 3.94 A U C E Y Z S 120 Foot 4 Foot 3 Hole pattern, cover Q ØP' PV-5027c Type Curve no. A B C D E F F F P P 2BH A380/ A382/ A384/ Type Curve no. Q S U V W Y x Z 2BH A380/ M 16 x 30 2 x M 40 x M 12 x A382/ A384/385 2BH1 943 (only cover mounting possible) Dimensions for fixing elements 2BX2 124 see page 52 (not included in the scope of supply of the pump/compressor). nash_elmo Industries _Series 53

54 Dimensions Dimensions for 2BH1 with converter (inch) 2BH BH1 600 F V2 V1 Type Curve no. A B F V1 V2 F V2 V1 B B 2BH AN21 A162e M25+M20 3 x M16 2BH AN31 A193e M25 2BH AN31 A223e BH AN01 A270e BH BH1 610 Type Curve no. A B F V1 V2 2BH1310-0AN21 A142e M25+M20 3 x M16 2BH1410-0AN41 A174e M25 2BH1510-0AN51 A205e BH1610-0AN31 A233e M25+M20 2BH1 800 F V2 V1 A J Type Curve no. A B F V1 V2 2BH AN01 A270e M25 3 x M16 54 nash_elmo Industries _Series

55 nash_elmo Industries _Series 55

56 Dimensions Dimensions for 2BH7 2., 2BH7 3., 2BH7 4., 2BH7 5., 2BH7 6. (inch) Type Curve no. A B B B1 C C2 D E F H H1 J K M N O P 2BH AH1. B140/ / 4 2BH AH1. B170/ (.71deep) - 0AH2. B172/173 2BH AH1. B200/ BH AH1. B230/ AH2. B232/233 2BH AH1. B260/ AH3. B263/ BH AH2. B150/ / 4-0AH5. B152/ (.71deep) 2BH AH5. B182/ BH AH2. B210/ AH5. B212/ BH AH2. B240/ AH7. B244/ BH AH3. B270/ AH5. B272/ Type Curve no. Q R S1 S2 S3 T T1 U V V 1 W X Y x Z 2BH AH1. B140/ M 6 x 17 M 25 x 1.5 M 16 x M 6 x 15 2BH AH1. B170/ AH2. B172/173 2BH AH1. B200/ BH AH1. B230/ M 8 x 15-0AH2. B232/233 2BH Ah1. B260/ AH3. B263/264 2BH AH2. B150/ AH5. B152/153 2BH AH5. B182/ BH AH2. B210/ AH5. B212/213 2BH AH2. B240/ AH7. B244/245 2 x M 32 x BH AH3. B270/ M 25 x AH5. B272/273 2 x M 32 x 1.5 Dimensions for 2BH7 63. (inch) Type Curve no. A B B C2 D E F H H1 K M N 2BH AH6.-. B282/ Type Curve no. O P Q R S1 S2 T U V W1 W2 2BH AH6.-. B282/ / M 6 x 17 for M 32 x (.71 deep) 56 nash_elmo Industries _Series

57 Dimensions for 2BH7 2., 2BH7 3., 2BH7 4., 2BH7 5., 2BH7 6. (inch) 2BH7 21. / 2BH7 31. / 2BH7 41. / 2BH7 51. / 2BH7 61. A B1 YxZ S3 V W A W2 S2 W1 V B U C2 J PV-5337a H Q P H1 V 1 Q P B C U X X PV-5341a O R J YxZ X 135 S2 H 90 Hole pattern, cover T T1 D E S1 N K M F 2BH7 22. / 2BH7 32. / 2BH7 42. / 2BH7 52. / 2BH7 62. A C2 S2 V W V 1 B' B U J PV-5310a O H Q P H1 R T T1 D E S1 N M F K Dimensions for 2BH7 63. (inch) 2BH7 63. B' O R T D E S1 N M F K nash_elmo Industries _Series 57

58 B Dimensions Dimensions for 2BH7 with converter (inch) 2BH BH7 610 F V2 V1 Type Curve no. B F V1 V2 B 2BH AN11 B141e M25+M20 3 x M16 2BH AN51 B145e M25 2BH AN21 B172e M25+M20 2BH AN61 B176e M25 2BH AN11 B201e M25+M20 2BH AN51 B205e M25 2BH AN21 B232e BH AN61 B236e BH AN31 B263e BH BH7 620 F V2 V1 Type Curve no. B F V1 V2 2BH AN51 B155e M25 3 x M16 2BH AN51 B185e BH AN81 B188e BH AN21 B212e BH AN51 B215e BH AN71 B247e BH AN31 B273e nash_elmo Industries _Series

59 a f c d 2BX2 065 f 2BX BX BX2 066 e 2BX BX BX BX4 086 e d a c f b c c d e h a a f Dimensions for suction-side through-filter (inch) 2BX BX BX4 082 d 2BX BX BX BX4 083 e Not included in the scope of delivery! g h g 2BX BX4 084 h k g h h g Not included in the scope of delivery! b ba i l m n l g m n Type a b c d e f g h i k l m n 2BX2 060 / 2BX4 060/ Ø / BX BX2 061 / 2BX4 081/ Ø / Ø BX2 064 / 2BX BX2 063 / 2BX Ø / / / BX2 065 / 2BX Ø Ø Ø BX2 066 / 2BX Ø Ø7.09 Ø Dimensions for suction filter (inch) 2BX BX4 066 d Model 01 Model 02 2BX BX BX BX BX BX BX BX BX BX BX BX4 080 e d Type Model a b c d e For / 2BH1 2BX2 100 / 2BX Ø BX2 101 / 2BX Ø BX2 102 / 2BX Ø Ø BX2 103 / 2BX Ø BX2 104 / 2BX Ø11.42 R2 1 / 2 2BX2 107 / 2BX Ø For 2BH7 2BX Ø BX Ø BX Ø b c e a nash_elmo Industries _Series 59

60 e d g a b f e d b c c f Dimensions Dimensions for additional silencer (inch) 2BX BX BX BX BX BX4 015 View X: 2BX BX BX BX BX BX4 012 g a View X: 2BX4 013 Type a b c d e f g 2BX Ø3.27 Ø BX Ø3.50 Ø BX Ø2.95 Ø BX Ø5.20 Ø / 2 2BX Ø6.57 Ø BX Ø8.23 Ø Ø8.27 2BX Ø3.46 Ø Dimensions for 90 elbow (inch) 2BX BX BX BX4 319 e f a d c b Type a b c d e f 2BX BX BX BX Dimensions for threaded flange (inch) 2BX BX BX BX BX BX BX BX BX BX4 042 f a b e c i g f a b e c h f a b e c f a b e h d d d Type a b c d e f g h i d 2BX / BX / BX / R BX BX BX Ø Ø BX / BX4 041 NPT BX4 042 NPT BX4 043 NPT nash_elmo Industries _Series

61 Dimensions for hose flange (inch) 2BX BX BX1 036 a b c a 2BX BX1 046 k b c a b c i g g e g e 2BX4 020 d f a h d f 2BX BX1 048 d d e a b b c c b c g h g e a e d f d f Type a b c d e f g h i k 2BX1 032 / 2BX4 020 Ø / BX1 033 Ø BX1 034 Ø R BX1 036 Ø BX1 046 Ø Ø8.27 Ø BX1 047 Ø / BX1 048 Ø Footprint Dimensions for vertical / horizontal mounting (inch) Type a b c d e f Type a b c d e f 2BX2 120 Ø M6 M6 2BX2 121 Ø M8 M8 2BX2 122 Ø M10 M10 2BX2 123 Ø M12 M12 2BX2 127 Ø M6 M6 2BX2 128 Ø M8 M8 2BX2 135 Ø M6 M6 2BX4 100 Ø M6 M6 2BX4 101 Ø M8 M8 2BX4 102 Ø M10 M10 2BX4 103 Ø M12 M12 2BX4 104 Ø M12 M12 2BX BX BX BX BX BX BX BX BX BX BX BX2 135 e f a d c b Dimensions for fixing clamp for 2BH1 943 (1 set = 4 feet) (inch) 2BX2 124 Foot 1 Foot 3 Foot 2 Foot 4 Hole pattern h Foot 2 a a b c Foot 1 g Foot 3 e Type a b c d e f g h i f d 2BX Ø M h Foot 4 nash_elmo Industries _Series 61

62 d Dimensions Dimensions for vacuum relief valve with adaptor (inch) 2BX BX BX BX2 172 for 2BH13/2BH7 c b g g 2BX BX BX BX2 172 for 2BH14 c d b g g d e 2BX BX2 146 c f a f e a b g g d e f a Type a b c d e f g 2BX2 141 / 142 2BH Ø Ø BX2 171 / 172 2BH Ø Ø BX2 145 / Ø Ø Dimensions for pressure relief valve with adaptor (inch) 2BX BX BX BX2 174 for 2BH13/ 2BH7 b d c g g 2BX BX BX BX2 174 for 2BH14 b d g g e 2BX BX2 148 f c a e a b g g e f a Type a b c d e f g 2BX2 143 / 144 2BH Ø Ø BX2 173 / 174 2BH Ø Ø BX2 147 / Ø Ø nash_elmo Industries _Series

63 f Dimensions for vacuum relief valve (supplied loose for pipeline mounting) (inch) 2BX BX2 114 c b 2BX BX BX2 154 h d d g a f c b a e Type a b c d e f g h 2BX2 110 / / 4 Ø1.63 Ø BX2 150 Ø3.15 Ø6.30 Ø Ø BX2 152 Ø4.92 Ø8.27 Ø Ø BX2 154 Ø7.87 Ø11.61 Ø Ø Dimensions for pressure relief valve (supplied loose for pipeline mounting) (inch) 2BX BX BX BX BX2 155 b a d d g a c c b e Type a b c d e f g 2BX2 111 / / 4 Ø1.63 Ø BX2 151 Ø3.15 Ø6.30 Ø Ø BX2 153 Ø4.92 Ø8.27 Ø Ø BX2 155 Ø7.87 Ø11.61 Ø Ø nash_elmo Industries _Series 63

64 An

65 nex Application examples Conversion tables 76 Physical basics for blower applications eneral safety information Quality 81 ATEX 82 Footnotes and Voltage Overview 83

66 _Series Application examples Air cushion generation for paper processing machines Several little blast pipes which are normally closed by ball valves are located in the table plate. When the balls are pressed down by the weight of a paper staple the valve is opened. Floating on an air cushion the paper now can be easily shifted and positioned. paper ball air Bust pipe Air cushioning for air tables Ball valves used in air tables follow the same principle of design as those used for paper cutting machines. As a result most manufacturers of paper cutting machines also offer air tables. Air table equipped with a gas ring compressor 66 nash_elmo Industries _Series

67 Vacuum generation for screen printing machines Blowers used in a suction table generate a vacuum which secures the paper sheets during the printing process to prevent slipping. pressure plate paper suction table blower Suction table for screen printing Powder spraying for printing machines (Dry and pressure spraying) Powder is sprayed on the paper immediately after printing to avoid smearing of wet colour and sticking of paper to the machine. For spraying an injector is used. blower powder container injector nozzle paper Powder spraying for printing machines nash_elmo Industries _Series 67

68 _Series Application examples Air arm for printing machines After passing the printing machine the sheets of paper are turned over and piled up. Both operations are supported by blast air. printing roller paper blower turn around grating paper stack Turning over paper by blast air Paper transport by air cushions To avoid smearing of wet paint the sheets of paper are blown against a detent with the printed on side facing down. detent transport system printed side of the paper Blast air transportation of printed paper 68 nash_elmo Industries _Series

69 Aeration of paper piles by blast air Piled sheets of paper often tend to stick together especially when their surface is very smooth. Blast air can be used for separation by forming air cushions between the sheets. blower paper stack Loosening stacked paper by blast air Suction of paper clippings (e.g. perforating machines, paper cutting machines, punchedcard machines, Hollerith machines etc.) The paper clippings can be collected in a filter equipped settling chamber after being sucked off right at their origin. pressure stamp blower filter equipped settling chamber Sucking in paper clippings at a vacuum table nash_elmo Industries _Series 69

70 _Series Application examples Evacuation of fruit packings Evacuation of fruit packings Packing eggs by suction air lifting, lowering, holding egg shifting conveyer belt Packing eggs by suction air 70 nash_elmo Industries _Series

71 Holding and clamping of workpieces workpiece Suction air generated by a gas ring blower is used to secure the workpiece during machining. This way of clamping is especially important for parts that can't be secured by magnetic forces (e.g. workpieces consisting of wood, plastics, ceramics and non-ferrous metals). worktable Clamping workpieces by suction air Conveying machinery Depending on their weight and size, the goods to be conveyed are secured by one or several suction cups. lifting, sinking suction cup rubber joint goods to be conveyed Lifting and transporting by suction air nash_elmo Industries _Series 71

72 _Series Application examples ranulated material conveyers Automated loading of molding presses and extruders. A blower generates a vacuum in the container for granulated material which is transported by the air flow. The gas ring blower is protected by a filter. filter pipe towards the molding press container for granulated material Pneumatic transportation of granulated material Respirators Fresh air is needed for breathing while working in polluted atmospheres. This is for example necessary in the chemical industry where big tanks, chambers etc. have to be cleaned. as ring blowers can provide fresh air for one or several respirators at the same time. A hose diameter of 1" and a maximal hose length of 15 ft are required. Another possibility is to pump fresh air into the protective helmet from above so that no pollutants are inhaled by the worker. hose Respirators 72 nash_elmo Industries _Series

73 Using suction air for dental appliances In dental equipment vacuum air is used to empty the basin and to suck in cooling water from the drill as well as saliva and blood. Such applications require gas ring blowers that are protected against corrosion. suction tube filter secretion Dental chairs Aeration of ponds Pumping air into fish-hatching tanks can improve living conditions for the animals. This speeds up breeding so that more fish per area can be caught. Aeration of ponds nash_elmo Industries _Series 73

74 _Series Application examples Dust exhaustion Waste from industrial production processes often consists of finegrained dust which is injurious to health. Therefore it must be collected and disposed of by either stationary or mobile devices. filter suction tube trap machine tool Stationary removal by suction filter filter / collector Mobile removal by suction Cleaning sewers by suction Suction trucks are widely used in the municipal sector for cleaning sewers. as ring blowers generate a vacuum which is used for sucking in soil or residue from sewers at a free air capacity of about 40 ft (plus vehicle height). exhaust piston inward pumping exhausting reversing valve filter Sewer pumping truck suction tube 74 nash_elmo Industries _Series sewer

75 workpieces Aeration of electroplating baths Air is blown through a perforated pipe into the electroplating bath to improve intermixture. In addition that air bubbles are kept off the workpiece's surface. electroplating bath Aeration of electroplating baths decontaminated exhaust air filter cover trap Soil ventilation devices Soil ventilation is used for soils that are unsaturated with volatile substances. This method is recommended for degassing BTX and LHKW contaminated soils. The range of degassing apparatus depends on the quantity, dissemination and saturation pressure of the pollutant as well as on the air flow in the subsoil. Depending on conditions mentioned above the range may vary between 33 and 262 ft. Exhaust air must be disposed of according to pollution control regulations (filtering, flaring etc.). unsaturated zone saturated zone ground water Soil-ventilation nash_elmo Industries _Series 75

76 Annex Conversion tables Pressure Beginning units Multiply by to get back conversion Suction capacity Beginning units Multiply by to get back conversion atm bar atm mbar atm 76. cm Hg atm in Hg atm kg/cm mbar in Hg mbar cm Hg mbar 100. Pa 0.01 mbar 10.2 mm H 2 O mbar 0.4 in H 2 O 2.49 mbar PSI in Hg 13.6 in H 2 O in Hg 0.49 PSI in H 2 O PSI m 3 /h ft 3 /h m 3 /h cfm 1.67 m 3 /h l/min 0.06 m 3 /h 4.4 gal/min cfm 7.48 gal/min Power Beginning units Multiply by to get back conversion kw 1.34 hp kw BTU/h BTU/h hp Types of pressure Absolute pressure The pressure measured from absolute zero, using ideal vacuum as the datum. The measured pressure is always greater than the reference pressure. Total pressure difference, pressure The pressure measured above the prevailing atmospheric pres sure. The datum is the prevailing atmospheric pressure and the measured pressure is always higher than the datum. Total pressure difference, vacuum The pressure measured lower than the prevailing atmospheric pressure. The datum is the prevailing atmospheric pressure and the measured pressure is always lower than the datum. Mass Beginning units Multiply by to get back conversion kg 2.2 lbs Length Beginning units Multiply by to get back conversion in 2.54 cm in feet 12 cm feet Temperature conversion Conversion from to F C t [ F] - 32 t [ C] = 1.8 C F t [ F] = 1.8 t [ C] + 32 Total pressure difference (vacuum) Total pressure difference (gauge) Absolute pressure PV % vacuum 0 mbar Atmospheric pressure approx mbar = 29,91inch Hg absolute 76 nash_elmo Industries _Series

77 Physical basics for blower applications Physical laws Variable Volume Pressure Power Speed change n 2 V 2 =V 1 n 1 n 2 p 2 =p 1 n 1 2 n 2 P 2 =P 1 n 1 3 Temperature change p 2 =p 1 ta 1 ta 2 Index: Density change 2 p 2 =p P 2 =P original (standard) 2 new Symbols: V Flow [cfm] n Drive speed [rpm] p Pressure [in Hg] or [PSI] P Power [hp] Density [lbs/cu.ft.] ta Temperature absolute [ F] (standard: =528 F) Examples 1. Flow dependent on speed A blower is operating at 3600 rpm and delivering 2000 cfm. If the speed is reduced to 3000 rpm, what is the new flow? V =V n 2 = n 1667 cfm Pressure dependent on altitude A blower is operating at an elevation of 5000 ft and is to deliver 3 PSI pressure. What pressure blower is required by standard conditions? p 2 =3 3.6 PSI ,92 in Hg barometric pressure sea level 24,89 in Hg barometric pressure at a 5000 feet-level When a blower is to operate at a high altitude it is frequently specified that the blower be capable of handling a given flow of standard conditions. It is then necessary to determine the equivalent flow of air at the higher altitude. 3. A blower is to operate at 5000 ft altitude and is to handle 2000 cfm of standard air. What is the flow of air the blower must handle at 5000 ft altitude? V 2 =V 1 = cfm nash_elmo Industries _Series 77

78 Annex 4. Pressure dependent on the speed ratio A blower is operating at a speed of 3600 rpm and delivering air at 3 PSI pressure. If the speed is reduced to 3000 rpm, what is the new pressure? 2 2 p =p n = = 3x n 2.08 PSI 1 5. Pressure dependent on the temperature A blower is to handle 200 F air at 3 PSI pressure. What pressure (standard) blower is required? ta p 2 =p 1 ta =3 = 3.75 PSI A blower is capable of delivering 3PSI pressure with standard air. What pressure will develop handling 200 F inlet air? ta p 1 =p 2 ta =3 = 2.4 PSI Barometric pressure of various altitudes Altitude barom. pressure p 6. Power dependent of speed ratio A blower is operating at a speed of 3600 rpm and requiring 10 hp. If the speed is reduced to 3000 rpm, what is the new required power? 3 P =P 2 = n 2 1 n 3600 = hp 1 Table for barometric pressure of various altitudes The pressure values generated with the following formulae: p [in Hg]= p [in Hg] 1-288[K] [K/ft] h[ft] 288 K p [hpa]= p [hpa] 1-288[K] [K/m] h[m] 288 K with p 0 = pressure at your location In the table is p 0 the standard air pressure in Hg or 1,013 mbar and feet = 0 the sea level. Formulae in accordance to CINA (Comité International de Navigation Aérienne) feet m inch Hg PSI hpa=mbar , , , , , ,500 1, ,000 1, ,500 1, ,000 1, ,500 1, ,000 1, ,500 1, ,000 2, ,500 2, ,000 2, ,500 2, ,000 2, ,500 2, ,000 3, ,500 3, ,000 3, ,500 3, ,000 3, ,500 3, ,000 3, ,500 4, ,000 4, ,500 4, ,000 4, nash_elmo Industries _Series

79 eneral safety information NOTE: The products in this catalogue are used in the capital goods industry consumer goods industry and in such sectors as agriculture the building industry and allied trades. This equipment has bare parts that are dangerous because they are live during operation; in some cases these are moving or rotating parts. Such parts could cause severe injury to persons and severe damage to property, for example in the event of unauthorised removal of protective covers, improper use, wrong operation or insufficient maintenance. The people in charge of safety must therefore guarantee that: only qualified personnel are allowed to work on or around this equipment; these persons have access at all times to the operating instructions supplied and all other elements of the product documentation when working with the equipment, and are obliged to systematically follow the instructions given therein; unqualified personnel are not allowed to work on these machines or equipment or in the vicinity thereof. Qualified personnel are persons who on account of their training, experience, instruction, knowledge of the appropriate standards, specifications, accident prevention regulations and the operating environment have been authorised by those responsible for plant safety to perform the necessary work and at the same time to recognise and circumvent potential hazards. Knowledge of first aid and familiarity with the pertinent life-saving equipment are also necessary. The barring of unqualified personnel from work on heavy-current equipment is regulated by DIN VDE 0105 or IEC 364. For the sake of clarity, the operating instructions supplied with the equipment cannot contain all the detailed information on possible design variants and in particular cannot take into account every conceivable type of installation, operation or maintenance. The operating instructions therefore basically contain only the information necessary to enable qualified personnel (see above) to operate the machines or equipment correctly in industrial applications. In the event that the machines or equipment are intended for service outside of industry, where more exacting demands may be placed on them (such as touch protection for children), the installation work must be supplemented by further protective measures that are to be implemented locally. Where clarifications are necessary, particularly with respect to lack of product-specific detailed information, please contact the sales office concerned, quoting the type designation and manufacturing number of the machine or equipment. It is advisable to arrange for our service centres to take charge of the necessary planning, installation, commissioning and after-sales service. nash_elmo Industries _Series 79

80 eneral delivery conditions Export regulations According to the current provisions (01/2003) of the erman and US export regulations, the products listed in this catalogue do not require any export permit. Export or re-export is therefore allowed without the permission of the competent authorities unless the Order on Foreign Trade lays down country-specific restrictions. This is subject to change. The markings given on the delivery slip and invoice are the decisive criteria. An export permit obligation may arise for specific countries as a result of the intended use of the products. Unless otherwise stated on the individual pages of this catalogue, we reserve the right to make changes, especially to the given values,dimensions and weights. Illustrations are not binding. Our eneral Conditions of Trade and Delivery apply. Electronic check of the dimensional accuracy of a _Series impeller. Trade marks All product designations are trade marks or product names of nash_elmo Industries or other companies. Responsible for the technical content Dipl.-Ing. Lutz Kasimir nash_elmo Industries mbh Corporate Communication Fully automatic final check of endshields of F_Series and _Series drives. 80 nash_elmo Industries _Series

81 Only quality has a future Technical progress and market success are inseparable from the high quality of nash_elmo products. To guarantee this high quality level, a reliable quality assurance system has been established for monitoring all phases of production from development to delivery. This quality assurance system meets the worldwide requirements, complies with the relevant standards and specifications and fulfills the requirements of ISO 9001:2000. This gives our customers the following advantages: Check of performance data and printing of the test protocol. maximum operational safety; high, consistent supply reliability; compliance with the requirements of the European Market; participation in national and international tenders. nash_elmo Industries _Series 81

82 ATEX information Since July 1, 2003, it is compulsory by law within the European Union to design explosionproof machines according to ATEX 94/9 E. Free trade within the EC for ATEX compliant machines and devices are therefore guaranteed due to European standardization of machine requirements. ATEX also includes non-electric devices that are a potential ignition source. A subdivision as/particle(dust) explosion protection according to ATEX results through the marking (as)/d (ust). The zones (according to RL 1999/92/E) represent work areas in which an explosive atmosphere 1) can occur. Depending upon the frequency and the duration of the appearance of the explosive atmosphere, ATEX subdivides different zones in which corresponding categories are assigned. Continuously or for longer periods of time Zone 0 (=) und 20 (=D) Devices of category 1 Occur occasionally Zone 1 (=) und 21 (=D) Devices of category (1 or) 2 Normally not likely to occur, or only for short periods of time Zone 2 (=) und 22 (=D) Devices of category (1, 2 or) 3 Our _200 and _400 ranges of gas ring compressors are produced according to the ATEX requirements. Machines in the EEx version have been discontinued and replaced by machines corresponding to the new directive, category 3. There is an ATEX version of every housing size of the _200 range available in category 3D, 3, 3/2D and 3/2 2). The side channel blowers comply with the temperature class T3 with a max. (surface) temperature of 125 C and correspond to the protection class IP55. For the category 3/2D, the blowers correspond to the protection class IP65.. All ATEX machines of the _200 series are available for the categories 3D, 3 and 3/2D as fixed voltage machines for 50 and 60 Hz. For the category 3/2, only a pure 50-Hz version is available. 1) Mixture of air (oxygen) and flammable gases, steam, powder. 2) 3/2 means: Category 3 inside, Category 2 outside 82 nash_elmo Industries _Series

83 _Series Voltage Overview Voltages at 50 Hz 4) 2BH c. c 3-phase V / V Y H 1 CUL US V / V Y H 6 CUL US V H 7 CUL US -500-V C 5 CUL US 1-phase 100/200 V V 4 CUL US 115/230 V V 5 CUL US /230 V A 1 Voltages at 60 Hz 4) 3-phase V / V Y H 1 CUL US V / V Y H 6 CUL US V H 7 CUL US -575 V C 5 CUL US 1-phase 100/200 V V 4 CUL US 115/230 V V 5 CUL US /115 V B 6 /230 V B 8 Voltages 3-phase ATEX 4) 50 Hz, categories 3D, 3, 3/2D 230 V / 400 V Y D V D V / 690 V Y D 6 50 Hz, category 3/2 230 V / 400 V Y D V D V / 690 V Y D 6 60 Hz, categories 3D, 3, 3/2D 460 V D V D V Y D 6 60 Hz, category 3/2 440 V Y V V 6 Specification of voltage in order number: Footnotes: 1) Measuring surface sound-pressure level acc. to EN , measured at a distance of 1 m. The pump is throttled to a medium inlet pressure, a hose is connected to the discharge side, and a vacuum-relief valve is not fitted. 2) For selection and ordering information, see accessories. The pressure limits of the valves are based on a cooling agent and ambient temperature of 25 C. 3) For 2BH1 943, only mounting on the end-casing is possible. 4) Tolerances: the motors comply with DIN EN /DIN IEC 34-1 and Insulation Class F: Three-phase: fixed voltages incl. ATEX ± 10% voltage range ± 5 % in compliance with UL and CSA -10%/+ 6 % (UL 507 u. CSA 22.2 No. 113) Single-phase: Fixed voltages: ± 5 % If during continuous operation only 90% of the maximum end pressure is used, the admissible tolerance increases to ± 10 %. In compliance with UL and CSA - 10 % /+ 6 % (UL 507 u. CSA 22.2 No. 113) Frequency: ±2 % The motors comply with the IEC and European norms quoted. The European norms replace the national norms of the following member states: ermany (VDE), France (NF C), Belgium (NBNC), reat Britain (BS), Italy (CEI), Netherlands (NEN), Sweden (SS), Switzerland (SEV) and others. The machines also comply with various national norms. The following norms have been adapted to the publications IEC and the motors can be used at standard rated performance: UL 507 USA CSA 22.2, No. 113 Canada IS 325 India IS 4722 NEK_IEC Norway Other voltages available upon request nash_elmo Industries _Series 83

84 Our product range L_Series Liquid ring vacuum pumps and compressors Chemical and petrochemical industry Process engineering Paper and pulp industry Power plants Plastics industry Medical technology Food industry eneral mechanical engineering D_Series Dry pumps Chemical and pharmaceutical industry Process engineering Metallurgy Packaging industry Food industry V_Series Vane pumps Chemical and petrochemical industry Food processing industry Packaging eneral mechanical engineering F_Series Radial Fans Plastics industry Printing industry lass industry Industrial furnaces Industrial vacuums S_Series Standardized systems Chemical industry Process industry Food processing industry Packaging Power generation and supply correction level: A2a/2005 nash_elmo Industries Corporate Headquarters Trumbull, CT USA 9 Trefoil Drive Trumbull, CT Tel.: European Headquarters Nürnberg, ermany Katzwanger Straße 150 D Nürnberg Tel.: Order-No: VNE:C-CA001-A2a-AM Printed in ermany Dispo NE 2238/059 pdf / All Rights Reserved HENNI Nbg

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000 Suction capacity in m /h m /h 20 2000 1000 0 00 2 200 1 100 10 700 0 0 400 00 200 100 0 100 200 00 400 0 0 700 800 900 1000 1100 Suction pressure auge pressure mbar ELMO- vacuum pumps and compressors convey

More information

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12 BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous

More information

Samos SI E1/E2

Samos SI E1/E2 Samos SI E/E Samos SI E Description Busch Samos SI regenerative blowers are designed for either pressure or vacuum. They are available in single and two stage models so they can operate over a wide range

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

APEX DYNAMICS, INC. Staianless

APEX DYNAMICS, INC. Staianless APEX DYNAMICS, INC. HIGH PRECISION PLANETARY GEARBOXES AE / AER Series Staianless High precision high speed planetary gearboxes AE / AER series Apex Dynamics, Inc. is the world s most productive manufacturer

More information

CNA-CNB. Centrifugal fans

CNA-CNB. Centrifugal fans NA-NB entrifugal fans Product facts Product Single-inlet low-pressure fans with backward-curved blades. Use In industrial ventilation systems for uncontaminated, non-corrosive air, max. 70 º, where a low

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

Digital AC Motors MHD

Digital AC Motors MHD Digital AC Motors MHD090 8-1 8 MHD090 8.1 Technical Data Description Symbol Unit MHD090B-035 Type of cooling Natural Natural Surface Liquid Motor overtemperature 60 K 100 K 60 K/100 K 60 K/100 K Electric

More information

BNA Series. PLENUM FAN with Backward Wheels

BNA Series. PLENUM FAN with Backward Wheels BNA Series PLENUM FAN with Backward Wheels BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a plenum.

More information

HiPace 1200, with TC 1200, DN 200 CF-F

HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled Benchtop, Underbench and Floorstanding Centrifuges classic/cooled PERFORMANCE Efficient, results-oriented working processes are top priority in both research and routine laboratories. Advanced laboratory

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m B a l t i m o r e A i r c o i l C o m p a n y Baltimore Aircoil Company is recognized as the world s largest manufacturer of evaporative heat transfer and thermal storage equipment. BAC products are supplied

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

System Components. Electric Motors.

System Components. Electric Motors. System Components Electric Motors www.powerjacks.com Contents.1. Electric Motors.1.1. AC Motors.1.. AC Motor Performance 0 rpm ( pole).1.. AC Motor Performance 00 rpm ( pole).1.. AC Motors with Integral

More information

Atlas Copco Air motors. A full range of compact, high performance air motors

Atlas Copco Air motors. A full range of compact, high performance air motors Atlas Copco Air motors A full range of compact, high performance air motors ATLAS COPCO AIR MOTORS AIR MOTOR FEATURES AND CHARACTERISTICS Air motors are compact and lightweight. An air motor weighs only

More information

YUNSHENG PERMANENT MAGNET SYNCHRONOUS MOTOR. YUNSHENG GROUP Ningbo YunSheng Co.,Ltd. Servo Control Division

YUNSHENG PERMANENT MAGNET SYNCHRONOUS MOTOR. YUNSHENG GROUP Ningbo YunSheng Co.,Ltd. Servo Control Division YUNSHNG PRMANNT MAGNT SYNCHRONOUS MOTOR YUNSHNG GROUP Ningbo YunSheng Co.,Ltd. Servo Control Division Add:No. 1 Yangfan Road, National Hi-Tech Zone,Ningbo, China Tel:0-21 26 261 Fax:0-269 mail:ys-sem@ysweb.com

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

DEBEM IM VERTICAL CENTRIFUGAL PUMPS.

DEBEM IM VERTICAL CENTRIFUGAL PUMPS. IM VERTICA CENTRIFUGA PUMPS The IM series of resin-encased vertical centrifugal pumps features high-performance pumps for fixed installations with pump immersed directly in the tank and operated by a directdrive

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

Method of Measuring Machinery Sound Within an Equipment Space

Method of Measuring Machinery Sound Within an Equipment Space ANSI/AHRI Standard 575 (Formerly ARI Standard 575) 2008 Standard for Method of Measuring Machinery Sound Within an Equipment Space Price $15.00 (M) $30.00 (NM) Printed in U.S.A. 8Copyright 1994, by Air-Conditioning

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres 1 EEX gerotor pump unit For use in oil circulation systems in gas- and dust-ex-atmospheres Gerotor pump series 1 EEX The 1 EEX product series has been specifically designed for centralized lubrication

More information

HiPace 300 with TC 400, DN 100 CF-F

HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 400 drive electronics Ideal

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

10-year industry best core warranty. 2-year warranty on balance of unit.

10-year industry best core warranty. 2-year warranty on balance of unit. MODEL FEATURES MERV-8 filters Fully insulated case Large cores for high efficiency No condensate pan or drain required AHRI Certified Rainhood included Access door for easy maintenance and Cleaning Integral

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

W250: Compact photoelectric switch series for a broad range of applications

W250: Compact photoelectric switch series for a broad range of applications W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications

More information

The Fundamentals of Moisture Calibration

The Fundamentals of Moisture Calibration The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Mercury Stack Monitor SM-4

Mercury Stack Monitor SM-4 Member of the envea Group Mercury Stack Monitor SM-4 Automatic continuous emission monitor (CEM) for mercury Continuous operation Sample dilution directly at stack - works with virtually any sample matrix

More information

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260

More information

Technical Explanation for Axial Fans

Technical Explanation for Axial Fans CSM_Axial_TG_E Introduction What Is an Axial? Axial fans are used for stable cooling in many different applications and locations. If the temperature of a device increases, the lives of its internal parts

More information

Simplicity Stability Speciality V

Simplicity Stability Speciality V Digital Flexo Imager ABOUT US True Image/True Color/True Print. CRON: taking the lead in revolutionizing the printing industry. A thousand years ago in the early Song Dynasty Bisheng invented man s first

More information

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM

UNI EN ISO 9001:2008 UNI EN ISO 14001:2004 BS OHSAS 18001:2007 EC DIRECTIVE 2014/34/EU (ATEX) CERTIFIED MANAGEMENT SYSTEM EN ISM-BSM CERTIFIED Technology Made in Italy Since 1955 the Varvel Group has been making speed reducers and variators for light industry applications. Reliable partner in power transmission equipment

More information

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors ZF Maschinenantriebe GmbH Industrial rives Planetary gearboxes Economy Series for Servomotors 2 ZF-uoplan 2K Two-speed Gearboxes ZF-Ecolift Elevator Gearboxes ZF-Servoplan G ompact Gearbox ZF-Tiratron

More information

Multi-Speed Three-Phase Induction Motors

Multi-Speed Three-Phase Induction Motors Multi-Speed Three-Phase Induction Motors Including Motors for Fan Applications Product Catalogue Multi-Speed Three-Phase Induction Motors Certificates Cantoni Motor SA ISO 0 KEMA Since September 0, 999

More information

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified

MULTISTAGE CENTRIFUGAL PUMP TPH 2/4/8/12/25/50T. 50Hz. WALRUS PUMP ISO 9001 Certified MULTISTAGE CENTRIFUGAL PUMP TPH /////T Hz WALRUS PUMP ISO Certified TPH Applications The WALRUS TPH Series is horizontal multistage centrifugal pump, suitable for clean water/liquid without abrasive matters.

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013

Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades. Issue 1.4 September 2013 Centrifugal Fans double inlet with direct drive backwardcurved true airfoil blades Issue 1.4 September 013 1 The overall picture will decide Complete systems by Nicotra ebhardt Depending on the model of

More information

Fundamentals of silencing and their practical application in screw compressor plants

Fundamentals of silencing and their practical application in screw compressor plants Fundamentals of silencing and their practical application in screw compressor plants Dr.-Ing. Johann Lenz Theory of sound Air or fluid-borne sound is generally considered as weak pressure fluctuations.

More information

Facts and figures MULTILIFT SELECT 15

Facts and figures MULTILIFT SELECT 15 Facts and figures MULTILIFT SELECT 15 www.arburg.com MULTILIFT SELECT 15 Technical data min. 180 Stroke Z-axis Stroke X-axis Clamping face fixed mould platen 220 E A D K Stroke Y axis 195 B 2) C 157 P

More information

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H3 Performance Series Product Specifications EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase,

More information

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev.

Submittals. Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* Rev. Submittals Advanced Series 1U09ES2VHA / AW09ES2VH* 1U12ES2VHA / AW12ES2VH* 1U18ES2VHA / AW18ES2VH* 1U24ES2VHA / AW24ES2VH* C US Intertek For more information visit us: www.haierductless.com www.haierductlesshelp.com

More information

Product description. Compact Modules. Characteristic features. Further highlights

Product description. Compact Modules. Characteristic features. Further highlights 4 Compact Modules Product description Characteristic features Five fine-tuned sizes based on a compact precision aluminum profile with two integrated pre-tensioned ball rail systems Identical external

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell Wireless Load Cell Features Standard single part line pull sizes ranging from 5,000 to 600,000 lb. All stainless frame and hardware Heavy duty construction from 17-4PH1150 stainless steel (17-4PH1025 on

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1 EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS FCP 2008 testing procedures FCP acoustical test method pag. 1 CONTENTS 1 - PURPOSE... 3 2 - NORMATIVE REFERENCES... 3 3 - DEFINITIONS... 3 3.1

More information

Mass Flow Meter and Controller

Mass Flow Meter and Controller ass Flow eter and Controller for Gases measuring monitoring analysing asuring range: 0-10 m N /min...0-500 N /min ccuracy: ±1.5% f.s. pmax 35 bar; tmax 50 C nalogue output: 0-5 V or 4-20 m Digital display

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

PFI Closed circuit cooling towers

PFI Closed circuit cooling towers PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information