Behaviour of asymmetric building with double variable frequency pendulum isolator

Size: px
Start display at page:

Download "Behaviour of asymmetric building with double variable frequency pendulum isolator"

Transcription

1 Structural Engineering and Mechanics, Vol. 34, No. 1 (2010) Behaviour of asymmetric building with double variable frequency pendulum isolator D.P. Soni Civil Engineering Department, Sardar Vallabhbhai Patel Institute of Technology, Vasad , India B.B. Mistry Engineering College, Tuwa , India V.R. Panchal Civil Engineering Department, Sardar Vallabhbhai Patel Institute of Technology, Vasad , India (Received May 12, 2009, Accepted October 7, 2009) Abstract. Presented in this paper is the behaviour of asymmetric building isolated by the double variable frequency pendulum isolator (DVFPI). The DVFPI is an adoption of single variable frequency pendulum isolator (VFPI). The geometry and coefficient of friction of top and bottom sliding surfaces can be unequal. The governing equations of motion of the building-isolation system are derived and solved in incremental form. The analysis duly considers the interaction of frictional forces in the two principal directions developed at each sliding surface of the DVFPI. In order to investigate the behaviour of the base isolation using the DVFPI, the coupled lateral-torsional response is obtained under different parametric variations for a set of six far-fault earthquake ground motions and criterion to optimize its performance is proposed. Further, influences of the initial time period, coefficient of friction and frequency variation factors at the two sliding surfaces are investigated. The numerical results of the extensive parametric study help in understanding the torsional behaviour of the structure isolated with the double sliding surfaces as in the DVFPI. It is found that the performance of the DVFPI can be optimized by designing the top sliding surface initially softer and smoother relative to the bottom one. Keywords: double variable frequency pendulum isolator; seismic isolation; asymmetric building; eccentricity; torsional coupling. 1. Introduction Great advances have been made in the development of base isolation technology to protect structures form the hazardous effect of strong earthquakes in the past three decades. A practical Research Scholar, soni_svit@yahoo.com Professor, bbm_7@yahoo.co.in Assistant Professor, Corresponding author, vijay_svit@yahoo.co.in

2 62 D.P. Soni, B.B. Mistry and V.R. Panchal base-isolation system typically consists of three basic elements (Buckle 1986): (1) A flexible mounting so that the fundamental period of the total system is lengthened sufficiently to reduce the acceleration response; (2) a supplemental damper or energy-dissipation device so that the relative displacement across the isolation interface can be controlled to a desirable level; and (3) a means of providing rigidity under low load levels such as wind and minor earthquakes. Excellent reviews of the base-isolation concepts and applications are available in published literature (Kelly 1986, Buckle and Mayes 1990, Naeim and Kelly 1999). Several investigations on the response of base isolated buildings are reported in literature. Most of the analytical works deal with 2-D idealization, which is strictly valid for symmetric buildings. In practice, symmetrical buildings are unlikely to occur and most buildings are unsymmetrical to some extent. The principal candidates leading to asymmetry are unsymmetrical building plan and elevation and unsymmetrical distribution of vertical members and masses on the floors. Compared to the buildings with symmetric configuration, such buildings are more susceptible to lateral loads especially earthquake hazards due to torsional coupling. It is the most important factor that differentiates between 3-D and 2-D idealization of the building and can result in significant response amplifications. Excessive edge deformation due to torsional coupling may cause pounding between closely spaced adjacent buildings. Torsional coupling has been identified as one of the major causes of poor performance or failure of buildings during recent earthquakes. The recognition of this fact has led several researchers to focus their study on the earthquake behaviour of such systems (Lee 1980, Pan and Kelly 1983, Eisenberger and Rutenberg 1986, Zayas et al. 1987, Nagarajalah et al. 1993a, Nagarajalah et al. 1993b, Jangid and Datta 1994, Jangid 1995, Jangid and Kelly 2001, Tena- Colunga and Gomez-Soberon 2002, Pranesh and Sinha 2004, Tena-Colunga and Escamilla-Cruz 2007). Recently there has been growing interest in the development of double sliding bearing principally owing to two reasons (Fenz and Constantinou 2006): (1) the displacement capacity of such isolator is twice that of the traditional isolator with a single sliding surface of identical plan dimensions permitting it to accommodate large sliding displacement imposed by severe earthquake ground motions, and (2) there is the capability to use sliding surfaces with varying isolator geometry and coefficients of friction at top and bottom sliding surfaces, giving the designer greater flexibility to optimize performance. Taking advantage of these extra design parameters, it may be possible to attain certain benefits in terms of performance that are not currently achievable. Looking to these merits, the double friction pendulum system (DFPS) (Fenz and Constantinou 2006, Tsai et al. 2005, Kim and Yun 2005) and the triple friction pendulum system (Fenz and Constantinou 2008a, 2008b) have been designed, tested and have already found numerous applications. These are the mainstream isolation system with thousands of bearing in service. Recently, the authors have proposed the double variable frequency pendulum isolator (DVFPI) (Soni et al. 2009). The double and triple friction pendulum bearings are made of well-known friction pendulum system (FPS) (Zayas et al. 1987) with spherical sliding surface whereas the DVFPI consist of two variable frequency pendulum isolators (VFPI) (Pranesh and Sinha 2000) having elliptical sliding geometry. Because of the elliptical sliding surface, isolator stiffness of the DVFPI decreases with increase in sliding displacement and therefore, the low-frequency resonant behaviour of the isolator can be attenuated. The similar displacement dependent isolator behaviour can also be achieved by using triple friction pendulum having multiple spherical surfaces rather than using variable curvature sliding surfaces. The triple friction pendulum bearing exhibits adaptive stiffness and damping characteristics. Its behaviour is dictated by the different

3 Behaviour of asymmetric building with double variable frequency pendulum isolator 63 combinations of surfaces upon which sliding can occur over the course of motion. As the surfaces upon which sliding occurs change, the stiffness and effective friction change accordingly. The performance of the DVFPI has been examined rigorously when subjected to unilateral, bilateral and triaxial ground excitations (Soni et al. 2009, Panchal et al. 2009). The torsional behaviour of asymmetric building isolated by the double bearings has not been investigated yet. In view of these, numerical studies have been carried out to examine the torsional behaviour of the DVFPI isolated asymmetric building under bilateral far-fault ground motions by performing 429 computer simulations. The objectives of this investigation are (a) to present mathematical formulation for the response of a three-dimensional torsionally coupled building isolated with the DVFPI duly considering interaction of frictional forces at both sliding surfaces, (b) to examine the criteria to optimize the performance of the DVFPI, (c) to study the response of asymmetric building for a set of important parametric variations applied individually and in combination, and (d) to examine the influence of isolator parameters on coupled lateral-torsional response. 2. Description of the DVFPI As mentioned earlier the DVFPI is an adaptation of the VFPI having elliptical sliding surface. Owing to the elliptical sliding surface, oscillation frequency of the VFPI decreases sharply with increase in sliding displacement. Consequently, the dominant frequency of excitation and the isolator frequency are not likely to tune. This property of frequency separation combined with forcesoftening mechanism of the VFPI makes the isolator performance independent of both amplitude and frequency of excitations (Pranesh and Sinha 2000). The characteristics of the VFPI can be made more effective by introducing a second sliding surface as shown in Fig. 1(a). This device is called the double variable frequency pendulum DFPS isolator. Since sliding is possible on both surfaces, the displacement capacity of the DVFPI is twice that of the traditional VFPI with a single sliding surface of identical plan dimensions. This key feature of the DVFPI permits it to accommodate large sliding displacement produced by severe earthquake ground motions. However, the details and operation of the DVFPI are almost same as the DFPS. The difference between the DFPS and the DVFPI is that the shape of both sliding surfaces in the DFPS is spherical (i.e., constant frequency) whereas that of the DVFPI is non-spherical. The isolator geometry defining upper surface and lower surface of the DVFPI may be unequal. The coefficient of friction of the upper and lower sliding surfaces are also not necessarily equal. To represent the geometry of the DVFPI, the equation of an ellipse proposed by Pranesh and Sinha (2000) is employed. Accordingly, the geometry of the top and bottom surfaces, respectively can be expressed as 2d z 1 b x 1 sgn( x 1 ) d 1 x 1 sgn( x 1 ) d 1 2 (1a) d 2 2 2d z 2 b x 2 sgn( x 2 ) d 2 x 2 sgn( x 2 ) (1b)

4 64 D.P. Soni, B.B. Mistry and V.R. Panchal Fig. 1 (a) Schematic details of the DVFPI, and (b) Hysteresis loops for different isolator properties where b 1 and b 2 are semi-minor axis of the top and bottom sliding surfaces, respectively; d 1 and d 2 are initial value of the semi-major axis of the top and bottom sliding surfaces, respectively; x 1 and x 2 depict the horizontal displacements of the articulated slider relative to the centre of the top and bottom sliding surfaces, respectively; and sgn(x 1 ) and sgn(x 2 ) are incorporated to maintain the symmetry of the top and bottom sliding surfaces about the central vertical axis. The signum functions have a value of +1 for positive value of sliding displacement and 1 for negative value of sliding displacement. The isolator forces F b1 and F b2 being imposed at the top and bottom sliding surfaces can be written as (Pranesh and Sinha 2000) F b1 k b1 ( x 1 )x 1 F 1 (2a)

5 Behaviour of asymmetric building with double variable frequency pendulum isolator 65 F b2 k b2 ( x 2 )x 2 F 2 (2b) where, ( ) k b1 ( x 1 ) m d m b k b2 ( x 2 ) m d m b m s ( ) 2 ω I ( 1 r 1 ) 2 ( 1 2r 1 ) 2 ω I ( 1 r 2 ) 2 ( 1 2r 2 ) (3a) (3b) gb 1 gb ω I ; 2 ω I d 1 2 ( ) d 2 2 x r 1 sgn x 1 x ; r 2 sgn x d 1 d 2 ( ) (4a, 4b) (5a, 5b) F 1 µ 1 ( m d m b )gsgn( x 1), F 2 µ 2 ( m d m b m s )gsgn( x 2) (6a, 6b) here r 1 and r 2 are the non-dimensional parameters for the top and bottom sliding surfaces; µ 1 and µ 2 are the coefficients of friction of top and bottom sliding surfaces; m d, m b and m s are the masses of the deck slab, base slab and slider, respectively; F 1 and F 2 are the frictional forces at the top and bottom sliding surfaces, respectively; k b1 ( x 1 ) and k b2 ( x 2 ) are the displacement dependent stiffnesses (i.e., variable stiffnesses) of top and bottom bearings, respectively; ω I1 and ω I2 are the initial frequencies of top and bottom bearings, respectively; and g is the acceleration due to gravity. The total relative displacement of the base mass, u b (between the centres of the top and bottom sliding surfaces) is the sum of the displacements on the top and bottom surfaces. u b x 1 x 2 (7) Substituting for x 1 and x 2 from Eqs. (2) into Eq. (7), the force-displacement relationship for the DVFPI can be obtained as k F b1 ( x 1 )k b2 ( x 2 ) b F u 1 k b2 ( x 2 ) F 2 k b1 ( x 1 ) b k c u b F c (8) k b1 ( x 1 ) k b2 ( x 2 ) k b1 ( x 1 ) k b2 ( x 2 ) where k c and F c are combined stiffness and combined frictional force of the DVFPI, respectively. Eq. (8) suggests that by defining two separate single VFPI and connecting them in series with a small mass of slider, the overall behaviour of the DVFPI can be obtained. The characteristic forcedisplacement relationships of the DVFPI are plotted in Fig. 1(b) for different isolator geometry and coefficient of friction of top and bottom sliding surfaces. It is interesting to note that the shape of the hysteretic loops shown in Fig. 1(b) is basically the same as those to be obtained in a ball-incone isolation system, which consists of a steel ball sandwiched between two conical steel load plates, as studied and tested by Kasalanati et al. (1997). The initial combined time period T c and combined coefficient of friction µ c of the DVFPI can be expressed from Eq. (8) as

6 66 D.P. Soni, B.B. Mistry and V.R. Panchal 2 2 T c T 1 T 2 (9) 2 2 µ 1 T 1 µ 2 T 2 µ c (10) 2 2 T 1 T 2 where T 1 and T 2 are the initial time period of top and bottom sliding surfaces. The force-displacement relationship of the DVFPI under bidirectional input motion can be extended from Eqs. (2) as F bx1 F by1 F bx2 F by2 k b1 ( r 1 ) k b1 ( r 1 ) k b2 ( r 2 ) k b2 ( r 2 ) x 1 F x1 y 1 F y1 x 2 F 2x y 2 F y2 (11) where F bxj and F byj are the isolator forces of top and bottom bearing in x- and y-directions, respectively; F xj and F yj are the frictional forces of top and bottom bearing in x- and y-directions, 2 2 respectively; r j x j y j is the relative radial displacement of the slider on jth sliding surface; k bj ( r j ) is the displacement dependent isolator stiffness of jth sliding surface as defined in Eqs. (3); and x j and y j are the relative displacements of the slider on jth sliding surface in x- and y-directions, respectively. Due to the elliptical sliding geometry of the DVFPI, the use of an articulated slider as shown in Fig. 1(a) would result in point contact or large concentration of pressure. Under such conditions, the capacity to carry load is limited, sliding friction has unpredictable behavior, frictional heating effects are significant and excessive wear to the sliding surfaces may occur. An alternative configuration to avoid some of these problems is the use of rolling contact, as done in Kasalanati et al (1997). This paper presumes that the configuration of Fig. 1(a) is practical and that stable and predictable friction is possible. 3. Structural model Fig. 2(a) shows a plan of idealized three-dimensional single-story building resting on the DVFPI installed between the base mass and foundation of the building. The assumptions made for the building-isolation system under consideration are as follows: 1. The superstructure is assumed linearly elastic. 2. The friction coefficient of the DVFPI is assumed to be constant and independent of the relative velocity at the sliding interface (Fan et al. 1990). 3. Although, a torsional moment develops at each isolator, the contribution of this torsional moment to the total torque exerted at the base mass is insignificant and hence is not included. 4. No overturning or tilting takes place in the superstructure during sliding over the DVFPI. 5. The DVFPI is isotropic (i.e., there is the same isolation period and the coefficient of friction in each of the two principal directions of the motion in the horizontal plane). The superstructure of the system consists of a rigid deck slab and columns. The lateral dimension of deck slab is d in x-direction and b in y-direction. The rigid deck slab is supported at the edges by

7 Behaviour of asymmetric building with double variable frequency pendulum isolator 67 Fig. 2 Structural model: (a) plan, (b) elevation massless, axially inextensible columns and the columns are connected to a rigid base slab. The CM is located at the geometrical centre of the deck slab, as the columns are modelled as massless and column masses are included in the slab mass. Each column has the same stiffness in the two principal directions. The stiffness distribution of the columns is symmetric about the x-axis but not about the y-axis, as a result, the structure exhibits a torsional effect when excited in the lateral y- direction. The system of isolators consists of an array of the DVFPI arranged between the foundation and the rigid base slab.

8 68 D.P. Soni, B.B. Mistry and V.R. Panchal The dynamic behaviour of the system under consideration to earthquake excitation can be described by the following eight degrees of freedom: the two translational displacements, u dx and u dy, in orthogonal directions and rotation, u dθ, about vertical axes of the centre of deck mass relative to the base mass; the two translational displacements, u bx and u by, in orthogonal directions and rotation, u bθ, about vertical axes of the centre of base mass relative to the ground; and the u sx and u sy, the displacements of slider relative to ground in x- and y-directions, respectively as shown in Fig. 2(b). Let k xi and k yi, i = 1, 2 N denote the lateral stiffnesses of the ith column in x- and y-directions, respectively, where N denote the number of columns in each direction. The total lateral stiffness of the system in each direction,, is given by K x K y N i 1 N i 1 K x k xi ; K y k yi (12) and the total torsional stiffness defined about the centre of mass (CM) of the deck is N ( ) i K θ k xi Y i k yi X i (13) where X i and Y i denote the x- and y-co-ordinates of the ith column with respect to the centre of mass of the deck slab, respectively. In Eq. (13) the torsional stiffness of each individual column element with respect to its longitudinal axis has been neglected. The eccentricity between the CM of the deck slab and the static centre of resistance (CR) of the columns is given by N 1 e x k yi X i ( ) K y i 1 Corresponding to the translational and rotational modes, the three uncoupled modal frequencies of the superstructure will be equal to K x K ω x ; y K ω y -----; θ ω θ (15) 2 m d m d m d r d in which, r d is the radius of gyration of the deck slab about the vertical axis through the CM. The frequencies ω x, ω y and ω θ may be interpreted as the natural frequencies of the fixed-base system if it were torsionally uncoupled but, m d, K x, K y and K θ are the same as in the coupled system. The torsional mass of the deck and the base mass are varied to provide various uncoupled torsional to lateral frequency ratios. This can be achieved by varying the position of the lumped mass with respect to the CM. Let k bi, i = 1, 2 NB denote the lateral stiffnesses of the ith DVFPI isolator in lateral directions, where NB denote the number of isolators in each direction. The total lateral stiffness of the jth sliding surfaces of the isolation system, K bj, is given by N K bj k bji i 1 where k bji represent the lateral stiffness of jth sliding surface of the ith isolator which is same in both x- and y-directions due to isotropic nature of the isolator. The torsional stiffness of the isolation (14) (16)

9 Behaviour of asymmetric building with double variable frequency pendulum isolator 69 system defined about the CM of the base slab is given by K bθ NB 2 2 ( ) i 1 k b1i Y bi k b1i X bi where, X bi and Y bi denote the x- and y-co-ordinates of the ith DVFPI with respect to the centre of mass of the base slab, respectively. The displacement of top sliding surface of ith DVFPI can be expressed in terms of displacement of CM of the base mass (17) u bxi u bx Y bi u bθ and u byi u by X bi u bθ (18a, 18b) The horizontal displacements of the slider, x ji and y ji of the ith DVFPI relative to the centre of the top and bottom sliding surfaces can be expressed from Eq. (7) as x 1i u bxi u sx and y 1i u byi u sy x 2i u sx and y 2i u sy (19a, 19b) (19c, 19d) Here, the torsional stiffness of each individual bearing is assumed to be small and is neglected. Moreover, for the purpose of simplification it is assumed that the bearings are symmetrically placed such that there is no eccentricity between the centre of mass and the centre of resistance. The isolator stiffness eccentricity, e bx between the CR and CM of the base slab is given by NB 1 e bx k b1i X bi ( ) K b i 1 The two uncoupled base isolation frequencies are defined as (20) ω b K b1 K and bθ ω bθ m d m b m d r d m b r b (21) Here, r b is the radius of gyration of the base about the vertical axis through the CM. The values of ω b and ω bθ are used to characterize the stiffness characteristics of the isolation device. It is worth noting that the eccentricity of the DVFPI isolation system does remain constant during earthquake ground motion. It changes with isolator displacement as the stiffness of the isolation system is a function of isolator displacement. Depending upon the displacement of the isolators, the variations in isolation eccentricity can be significant (Eq. (20)). 4. Governing equations of motion The governing equations of motion for the three-dimensional superstructure, base mass and slider are expressed in matrix form as M u [ b ] b [ M u ] d { } [ C] { u d} [ K] { u d } [ M] r { } [ ] u b u g { } [ K b1 ]{ u 1 } { F 1 } [ C] { u d} [ K] { u d } [ M b ][ r u ]{ g} { } [ K b1 ]{ u 1 } { F 1 } [ K b2 ]{ u 2 } { F 2 } [ M s ][ r u ]{ g} M u [ s ] s (22) (23) (24)

10 70 D.P. Soni, B.B. Mistry and V.R. Panchal wherein [ M], [ K] and [ C] are the lumped mass, stiffness and damping matrices, respectively, corresponding to the DOF at the deck; { u d } { u dx, u dy, u dθ } T is the vector of displacements at the deck relative to the base mass; { u b } { u bx, u yb, u bθ } T is the vector of displacements at the base mass; u u u { g} { gx, gy} T is the vector of ground accelerations, u and u gx gy are the ground accelerations in the x- and y-directions, respectively; and [r] is the earthquake influence coefficient matrix; [M b ] is the lumped mass matrix corresponding to the DOF at the base mass; [M s ] is the lumped mass matrix corresponding to the DOF at the slider; [M bj ] is the stiffness matrices of jth sliding surfaces of the isolation system, respectively; { F 1 } { F x2, F y2, F θ } T and { F 2 } { F x2, F y2 } T are the vector of frictional forces at top and bottom sliding surfaces of the isolation system, respectively, F xj and F yj are the frictional forces in the x- and y-directions, respectively on the corresponding sliding surface, F θ is the frictional force about the vertical axis; The damping matrix [C] is not explicitly known. It is constructed from the assumed modal damping for the fixed-base structure using its mode shapes and frequencies. If α is the angle of incidence of ground acceleration wave with respect to the x-axis, then the matrix [r] is given by [ r] cosα The stiffness matrices [K] and [K bj ] are written as sinα sinα cosα 0 0 N T [ K] [ a i ][ k i ][ a i ] i 1 (25) (26) where, [ k i ] k xi k yi and [ a i ] 1 0 y i 0 1 x i y i x i 1 (27, 28) NB T [ K bj ] [ a bi ][ k ji ][ a bi ] i 1 (29) where, [ k ji ] k bji k bji and [ a bi ] 1 0 y bi 0 1 x bi y bi x bi 1 (30, 31) in which [a i ] and [a bi ] respectively. are the transformation matrices of the ith column and the isolator,

11 Behaviour of asymmetric building with double variable frequency pendulum isolator Solution of equations of motion Due to non-linear force-deformation behaviour of the DVFPI and significant difference in damping of superstructure and the isolation system the governing equations of motion of the base isolated structure cannot be solved using the classical modal superposition technique. Therefore, they are solved in the incremental form using Newmark s step-by-step method assuming linear variation of acceleration over small time interval in this study. The frictional forces are obtained by hysteretic model, which is a continuous model of the frictional force proposed by Constantinou et al. (1990), using Wen (1976) equation. In the hysteretic model, the interaction between the frictional forces has been expressed by coupling of the hysteretic displacements components in two directions (Park et al. 1986). Due to highly non-linear behaviour of the system, and the strong influence of initial conditions at each time-step on the numerical solution, a very small time step of the order of has been found suitable for step-by-step solution. The complete procedure of the solution of equations of motion can be found in Panchal et al. (2009). 6. Parametric study The response of asymmetric building isolated with the DVFPI to the selected ground motions is investigated with respect to the following parameters: eccentricity ratio of the superstructure, e x /d, ratio of uncoupled torsional to lateral frequencies of the superstructure, ω θ /ω x, uncoupled time period of the superstructure, T x, and mass ratio, m b /m d. Since these parameters predominantly influence the torsional coupling and base isolation characteristics, the range of these parameters was carefully selected in order to obtain a better understanding of the influence of the system parameters on torsional coupling. The specifications for the values of the other parameters are: lateral dimension, b d 10.0 m ; number of the DVFPI isolators is 4; modal damping for the superstructure is taken as 2 per cent of the critical damping for all modes; and the ratio of mass of slider to mass of base slab, m s /m b is taken as Six response quantities, viz. peak rotation of deck slab, u θ, peak rotation of base slab, u bθ, peak base torque, peak resultant isolator displacement, u br, peak base shear in y-direction and deck corner displacement magnification (Nagarajalah et al. 1993a) are considered for the present study. The deck corner displacement provides the magnitude of deformation due to the combined effect of translation and torsion. By investigating the extent of magnification of deck corner displacement in comparison with the displacement at the centre of mass of the deck, the effect of torsional coupling can be qualitatively evaluated. For this purpose, the corner displacement magnification is utilized. It is defined as the ratio of peak deck corner displacement (relative to base) to peak displacement at the CM (relative to base). The parametric variations in isolation eccentricity, e bx /d, and the ratio of uncoupled torsional to lateral frequencies of the isolator, ω bθ /ω b are not presented explicitly due to continuous variation in restoring force of the DVFPI and hence in e bx/d and ωbθ /ωb during earthquake ground motion. However, the present formulation includes these variations in its mathematical model consequently these effects are automatically reflected in the analysis results. The structural response is obtained under a set of six far-fault ground motions having magnitude ranging from 6.6 to 7.0 recorded at a distance of 8 to 16 km on firm soil or rock site. The ground motions selected are representative of typical Large-Magnitude-Small-distance ground

12 72 D.P. Soni, B.B. Mistry and V.R. Panchal Table 1 Details of earthquake ground motions used in the study Earthquake Imperial Valley, 1940 (El Centro) Loma Prieta, 1989 (Saratoga Aloha Ave.) Superstition Hills, 1987 (El Centro Imp. Co. Center) Loma Prieta, 1989 (Capitola) Northridge, 1994 (Canoga Park - Topanga Canyon) Northridge, 1994 (Northridge-Saticoy St.) Magnitude Applied in x-direction Component PGA (g) Applied in y-direction Component PGA (g) Distance from surface projection of the fault (km) Fig. 3 Acceleration and displacement spectra of the six far-fault ground motions for 5 per cent damping

13 Behaviour of asymmetric building with double variable frequency pendulum isolator 73 Table 2 Properties of the different DVFPI design cases Group Case T 1 (sec) T 2 (sec) T c (sec) µ 1 µ 2 µ c Remark A T 1 T 2 µ 1 µ 2 A T 1 <T 2 ; µ 1 <µ 2 A T 1 <T 2 ; µ 1 >µ 2 A T 1 >T 2 ; µ 1 >µ 2 A T 1 >T 2 ; µ 1 <µ 2 B T 1 = T 2 µ 1 = µ 2 B T 1 =T 2 ; µ 1 =µ 2 C C T 1 =T 2 ; µ 1 <µ 2 T 1 = T 2 µ 1 µ 2 C T 1 =T 2 ; µ 1 >µ 2 D D T 1 <T 2 ; µ 1 =µ 2 T 1 T 2 µ 1 = µ 2 D T 1 >T 2 ; µ 1 =µ 2 Fig. 4 Comparison of median response quantities for various cases of the DVFPI design

14 74 D.P. Soni, B.B. Mistry and V.R. Panchal motion records. The characteristics of these earthquakes are listed in Table 1 and their displacement and acceleration spectra for 5 per cent damping are shown in Fig. 3. The stronger component among the two lateral components is applied in a direction perpendicular to the direction of eccentricity. In order to study the optimum performance of the DVFPI supporting asymmetric building, nine different isolator design cases have been considered as listed in Table 2. These are categorised into four groups depending on the isolator geometry and coefficient of friction of top and bottom sliding surface as (a) unequal isolator geometry and unequal coefficient of friction, (b) equal isolator geometry and equal coefficient of friction, (c) unequal isolator geometry and equal coefficient of friction, and (d) equal isolator geometry and unequal coefficient of friction of the two sliding surfaces. The isolators have been design to give same combined initial time period, T c, and coefficient of friction, µ c, for all design cases to make meaningful comparison among them. The median response of the example system for all design cases are plotted in Fig. 4. As observed from the figure that most of the response quantities minimize for A 4 Case, i.e., the DVFPI with higher initial time period and lesser coefficient friction of the top sliding surface relative to the bottom one. Fig. 5 Effect of e x /d on the response of the asymmetric building isolated with the DVFPI; T x = 1 sec, ω θ /ω x = 1.0, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3

15 Behaviour of asymmetric building with double variable frequency pendulum isolator 75 This observation suggests that in order to optimize the performance of the DVFPI for torsion the top sliding surface should be made initially softer and smoother than the bottom surface. Moreover, it should be noted that initially stiffer and smoother top sliding surface (Case A 1 ) amplifies the responses. 6.1 Effect of superstructure eccentricity The superstructure stiffness eccentricity, e x /d is the most important parameter causing torsional coupling and torsional motions. Fig. 5 is plotted to show the effects of superstructure eccentricity in torsionally coupled structure isolated with the DVFPI (T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.04, d 1 = 0.3 m and d 2 = 0.3 m), under the six selected ground motions. The median response of the six earthquakes is also plotted in the figure. The superstructure eccentricity is varied from a symmetric case, e x /d = 0 to asymmetric case, e x /d = 0.4. As shown in figure that the eccentricity increases torsional responses, i.e., the deck slab rotation, base slab rotation and base torque. Fig. 6 Effect of ω θ /ω x on the response of the asymmetric building isolated with the DVFPI; T x = 1 sec, e x /d = 0.15, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3

16 76 D.P. Soni, B.B. Mistry and V.R. Panchal However, the lateral responses, i.e., resultant isolator displacement and peak base shear are not much influenced by superstructure eccentricity. Further, the deck corner displacement magnification also increases with eccentricity as expected. 6.2 Effect of torsional to lateral frequency ratio of the superstructure The ratio of uncoupled torsional to lateral frequency is an important parameter in the behaviour of the asymmetric buildings; that is, highly influences the response of such systems. As shown in Fig. 6 with the increase of ω θ /ω x in the range of 0.8 ω θ /ω x 1, the deck corner magnification and deck slab rotation increases, remains nearly constant in the range of 1 ω θ /ω x 1.5 and decreases as the system become stiffer. Base torque and base rotation on the other hand decreases continuously with the increase of ω θ /ω x. Further, the lateral responses remain essentially insensitive to the variation of ω θ /ω x. Thus, the e x /d and ω θ /ω x G have opposing effects on the coupled lateral-torsional response. It will Fig. 7 Combined effect of e x /d and ω θ /ω x on the response of the asymmetric building isolated with the DVFPI; T x = 1 sec, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3

17 Behaviour of asymmetric building with double variable frequency pendulum isolator 77 Fig. 8 Effect of T x on the response of asymmetric building isolated with the DVFPI; e x /d = 0.15, ω θ /ω x = 1, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3 be interesting to examining the combined effect of these two parameters. This is explained by three dimensional plots of response for Imperial Valley, 1940 (El Centro) earthquake ground motion for the aforesaid combination in Fig. 7. The figure indicates that the superstructure eccentricity increases the torsional response quite rapidly than the uncoupled torsional to lateral frequency ratio suppresses them. This observation suggests that it is advisable to control the eccentricity rather than increasing the torsional stiffness to reduce torsional responses. 6.3 Effect of uncoupled time period of superstructure In Fig. 8, response of the DVFPI isolated asymmetric building is plotted for different values of superstructure time period, T x. Increasing the T x thereby making superstructure flexible in horizontal direction all the torsional responses increase and lateral responses decrease. The deck corner displacement magnification on the other hand decreases due to increase in deck lateral displacement with the increase in superstructure flexibility.

18 78 D.P. Soni, B.B. Mistry and V.R. Panchal Fig. 9 Effect of m b /m d on the response of the asymmetric building isolated with the DVFPI; T x = 1, e x /d = 0.15, ω θ /ω x = 1, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = Effect of mass ratio Fig. 9 depicts the influence of variation in mass ratio, m b /m d, on the structural response. The base shear is highly influenced by variation of m b /m d. This is expected as the base shear is directly proportional to the weight of the building. The base torque and deck slab rotation increases slowly with the increases of mass ratio. However, the base rotation, deck corner displacement magnification and the resultant isolator displacement remains almost same for all values of mass ratio. 6.5 Effect of angle of incidence In Fig. 10, the variation of the structural response is plotted against the angle of incidence, α for the six ground motions. The figure indicates that the responses are moderately influenced by

19 Behaviour of asymmetric building with double variable frequency pendulum isolator 79 Fig. 10 Effect of α on the response of the asymmetric building isolated with the DVFPI; T x = 1, e x /d = 0.15, ω θ /ω x = 1, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3 the angle of incidence of ground acceleration with respect to the principal direction of the structure. 6.6 Influence of isolator geometry The isolator geometry of the DVFPI can be completely defined by parameter b i and d i. As the initial time period, T i is directly proportional to b i, the influence of isolator geometry is studied by varying d 1, d 2 and T 1, T 2. The value of d i and T i are varied within range of m and sec, respectively. It should be noted that the reciprocal of d i is the FVF i of corresponding sliding surface. To study the effect of d 1 and d 2, other parameters are kept equal, i.e., µ 1 = µ 2 = µ c and T 1 = T 2 = T c. Fig. 11 shows three dimensional plots of response quantities considered for Imperial Valley, 1940 (El Centro) ground motion. It is seen that for the given value of d 1 the torsional response is independent of d 2. Figure also suggests that for lower value of d 1 (i.e., higher value of the FVF 1 ) the

20 80 D.P. Soni, B.B. Mistry and V.R. Panchal Fig. 11 Variations in peak response quantities of the DVFPI isolated torsionally coupled building for different values of T 1 and T 2 ; T x = 1, e x /d = 0.15, ω θ /ω x = 1, m b /m d = 1.0, µ 1 = 0.04, µ 2 = 0.07, d 1 = 0.3 and d 2 = 0.3 lateral response is essentially independent of d 2 (i.e., the FVF 2 ). However, for higher value of d 1, the lateral responses are sensitive to d 2. Further, the deck corner displacement magnification is not influenced by variations in FVFs. Fig. 12 portrays the influence of initial time period of top and bottom sliding surface on the seismic response of the DVFPI. As shown in figure, the response varies more rapidly within small range of T 1 and T 2 showing its sensitivity for lower value of initial time period of both sliding surfaces. For higher value of T 1, the torsional responses are essentially independent of T Influence of coefficient of friction The influence of coefficient of friction is studied by varying µ 1 and µ 2 at the two sliding surfaces in the range of , keeping other parameters constant, i.e., T 1 = T 2 = T c and d 1 = d 2 = 0.3 m and is shown in Fig. 13. The response is found sensitive for all values of coefficient of friction. Increasing friction coefficient, the limiting value of sliding force increases. As a result, more force

21 Behaviour of asymmetric building with double variable frequency pendulum isolator 81 Fig. 12 Variations in peak response quantities of the DVFPI isolated torsionally coupled building for different values of d 1 and d 2 ; T x = 1, e x /d = 0.15, ω θ /ω x = 1, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, µ 1 = 0.04, µ 2 = 0.07 will be transmitted by the sliding surfaces into the superstructure which in turn magnifies all responses quantities except resultant isolator displacement. 7. Conclusions The non-linear response of a torsionally coupled system isolated with double variable frequency pendulum system (DVFPI) to bilateral far-fault ground motions is obtained by considering the interaction of frictional forces in two orthogonal directions. The response behaviour of the torsionally coupled system is studied for a set of important parametric variations. The criterion to optimize the performance of the DVFPI for coupled lateral-torsional response is proposed. Further, the influences of the initial time period, the coefficient of friction and the frequency variation factors at the two sliding surface are investigated. The conclusions of this study are based on the

22 82 D.P. Soni, B.B. Mistry and V.R. Panchal Fig. 13 Variations in peak response quantities of the DVFPI isolated torsionally coupled building for different values of µ 1 and µ 2 ; T x = 1, e x /d = 0.15, ω θ /ω x = 1, m b /m d = 1.0, T 1 = 1.5 sec, T 2 = 2.0 sec, d 1 = 0.3 and T x = 0.3 assumption of stable and predictable sliding friction at the sliding interfaces, which are configured as depicted in Fig. 1(a). As discussed earlier in this paper, this may not be possible due to high concentration of pressure at the sliding interface. The following conclusions may be drawn from the trend of numerical results of the present study: 1. For the optimum performance of the DVFPI supporting asymmetric building, the top sliding surface should be designed initially softer and smoother. 2. The superstructure eccentricity magnifies the torsional response and the uncoupled torsional to lateral frequency ratio reduces it. However, the superstructure eccentricity increases the torsional response quite rapidly than the uncoupled torsional to lateral frequency ratio suppresses them. Therefore, the superstructure eccentricity should be control rather than making superstructure torsionally stiff. 3. The superstructure flexibility magnifies torsional response and reduces lateral responses and deck corner displacement magnification of the DVFPI system. 4. The torsional responses are not much influenced by the ratio of base mass to deck mass.

23 Behaviour of asymmetric building with double variable frequency pendulum isolator 83 However, base shear increases significantly with the mass ratio. 5.The angle of incidence of the ground motions with respect to the principal direction of structure moderately influences the performance of the DVFPI system. 6. For the given value of frequency variation factor of top sliding surface of the DVFPI, the torsional response is independent of frequency variation factor of bottom sliding surface. 7. When the top sliding surface of the DVFPI is design to have lower initial time period, the torsional response becomes sensitive to the initial time period of bottom sliding surface. On the other hand, for higher value of initial time period of top sliding surface, the response is independent of the initial time period of bottom sliding surface. 8. The torsional response is significantly influenced by coefficient of friction of both sliding surfaces. Increasing coefficient of friction either at top or bottom or both sliding surfaces of the DVFPI torsional response magnifies considerably. References Buckle, I.G. (1986), Development and application of base isolation and passive energy dissipation: A world review, ATC-17, Applied Technology Council, Redwood City, California. Buckle, I.G. and Mayes, R.L. (1990), Seismic isolation: History, application and performance-a world overview, Earthq. Spectra, 6(2), Constantinou, M.C., Mokha, A.S. and Reinhorn, A.M. (1990), Teflon bearings in base isolation II: Modelling, J. Struct. Eng., ASCE, 116(2), Eisenberger, M. and Rutenberg, A. (1986), Seismic base isolation of asymmetric shear buildings, Eng. Struct., 8(1), 2-8. Fan, F.G., Ahmadi, G. and Tadjbakhsh, I.G. (1990), Multi-story base-isolated buildings under a harmonic ground motion-part II: Sensitivity analysis, Nucl. Eng. Des., 123(1), Fenz, D.M. and Constantinou, M.C. (2006), Behaviour of the double concave friction pendulum bearing Earthq. Eng. Struct. Dyn., 35(11), Fenz, D.M. and Constantinou, M.C. (2008a), Spherical sliding isolation bearings with adaptive behavior: Theory, Earthq. Eng. Struct. Dyn., 37(2), Fenz, D.M. and Constantinou, M.C. (2008b), Spherical sliding isolation bearings with adaptive behavior: Experimental verification, Earthq. Eng. Struct. Dyn., 37(2), Jangid, R.S. (1995), Seismic response of an asymmetric base isolated structure, Comput. Struct., 60(2), Jangid, R.S. and Datta, T.K. (1994) Non-linear response of torsionally coupled base isolated structure, J. Struct. Eng., ASCE, 120(1), Jangid, R.S. and Kelly, J.M. (2000), Torsional displacement in base-isolated buildings, Earthq. Spectra, 16(2), Kasalanati, A., Reinhorn, A.M., Constantinou, M.C. and Sanders, D. (1997), Experimental study of ball-in-cone isolation system, Proc. Structures Congress XV, ASCE, Portland, Oregon. Kelly, J.M. (1986), Aseismic base isolation: Review and bibliography, Soil Dyn. Earthq. Eng., 5(4), Kim, Y.S. and Yun, C.B. (2005), Analysis and design of double friction pendulum systems for seismic isolation, The Second International Conference on Structural Health Monitoring of Intelligent Infrastructure, Korea. Lee, D.M. (1980), Base isolation for torsion reduction in asymmetric structure under earthquake loading, Earthq. Eng. Struct. Dyn., 8(4), Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures: From Theory to Practice, Wiley, New York. Nagarajalah, S., Reinhorn, A.M. and Constantinou, M.C. (1993a), Torsional coupling in sliding base isolated structures, J. Struct. Eng., ASCE, 119(1),

24 84 D.P. Soni, B.B. Mistry and V.R. Panchal Nagarajalah, S., Reinhorn, A.M. and Constantinou, M.C. (1993b), Torsion in base isolated structures with elastomeric isolation systems, J. Struct. Eng., ASCE, 119(10), Pan, T.C. and Kelly, J.M. (1983), Seismic response of torsionally coupled base isolated structures, Earthq. Eng. Struct. Dyn., 11(6), Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), Random vibration of hysteretic systems under bidirectional motions, Earthq. Eng. Struct. Dyn., 14(4), Pranesh, M. and Sinha, R. (2000), VFPI: An isolation device for aseismic design, Earthq. Eng. Struct. Dyn., 29(5), Pranesh, M. and Sinha, R. (2004), Behavior of torsionally coupled structures with variable frequency pendulum isolator, J. Struct. Eng., ASCE, 130(7), Panchal, V.R., Jangid, R.S., Soni, D.P. and Mistry, B.B. (2009), Response of double variable frequency pendulum isolator under triaxial ground excitations, J. Earthq. Eng. (in press). Soni, D.P., Mistry, B.B., Jangid, R.S. and Panchal, V.R. (2009), Seismic response of the double variable frequency pendulum isolator, Struct. Control Health Monit. (in press). Tena-Colunga, A. and Escamilla-Cruz, J.L. (2007), Torsional amplifications in asymmetric base- isolated structures, Eng. Struct., 29(2), Tena-Colunga, A. and Gomez-Soberon, L. (2002), Torsional response of base-isolated structures due to asymmetries in the superstructure, Eng. Struct., 24(12), Tsai, C.S., Chiang, T.C. and Chen, B.J. (2005), Experimental evaluation of piecewise exact solution for predicting seismic responses of spherical sliding type isolated structures, Earthq. Eng. Struct. Dyn., 34(9), Wen, Y.K. (1976), Method for random vibration of hysteretic systems, J. Eng. Mech. Div., ASCE, 102(2), Zayas, V., Low, S. and Mahin, S. (1987), The FPS system: Experimental report, Report No. UCB/EERC-87-01, Earthquake Engineering Research Centre, Berkeley, California.

Effect of bearing characteristics on the response of friction pendulum base-isolated buildings under three components of earthquake excitation

Effect of bearing characteristics on the response of friction pendulum base-isolated buildings under three components of earthquake excitation Effect of bearing characteristics on the response of friction pendulum base-isolated buildings under three components of earthquake excitation M.Rabiei Department of Civil Engineering, University of AmirKabir,

More information

Aseismic design of structure equipment systems using variable frequency pendulum isolator

Aseismic design of structure equipment systems using variable frequency pendulum isolator Aseismic design of structure equipment systems using variable frequency pendulum isolator Pranesh Murnal a, Ravi Sinha b, a Department of Applied Mechanics, Government College of Engineering, Karad 415124,

More information

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events Luigi Petti, Fabrizio Polichetti, Bruno Palazzo Dipartimento di Ingegneria Civile dell Università degli Studi

More information

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device A. Krishnamoorthy Professor, Department of Civil Engineering Manipal

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 11, November -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Study

More information

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES Octoer 12-17, 28, Beijing, China INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES M. Garevski 1 and M. Jovanovic 2 1 Director, Professor, Institute of Earthquake Engineering

More information

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR M PRANESH And Ravi SINHA SUMMARY Tuned Mass Dampers (TMD) provide an effective technique for viration control of flexile

More information

Seismic response of multi-story structure with multiple tuned mass friction dampers

Seismic response of multi-story structure with multiple tuned mass friction dampers Int J Adv Struct Eng (215) 7:81 92 DOI 1.17/s491-14-79-9 ORIGINAL RESEARCH Seismic response of multi-story structure with multiple tuned mass friction dampers Alka Y. Pisal Received: 2 July 213 / Accepted:

More information

Comparison of base-isolated liquid storage tank models under bi-directional earthquakes

Comparison of base-isolated liquid storage tank models under bi-directional earthquakes Vol.5, No.8A1, 27-37 (2013) http://dx.doi.org/10.4236/ns.2013.58a1004 Natural Science Comparison of base-isolated liquid storage tank models under bi-directional earthquakes Sandip Kumar Saha *, Vasant

More information

1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing

1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing 1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing Qiang Han 1, Jianian Wen 2, Liangliang Lin 3, Junfeng Jia 4 Key Laboratory of Urban Security and Disaster

More information

Behaviour of the double concave Friction Pendulum bearing

Behaviour of the double concave Friction Pendulum bearing EARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS Earthquake Engng Struct. Dyn. 2006; 35:1403 1424 Published online 19 June 2006 in Wiley InterScience (www.interscience.wiley.com)..589 Behaviour of the double

More information

SEISMIC RELIABILITY ANALYSIS OF BASE-ISOLATED BUILDINGS

SEISMIC RELIABILITY ANALYSIS OF BASE-ISOLATED BUILDINGS International Symposium on Engineering under Uncertainty: Safety Assessment and Management January 4 to 6, 2012 Paper No.: CNP 070 SEISMIC RELIABILITY ANALYSIS OF BASE-ISOLATED BUILDINGS M.C. Jacob 1,

More information

Response of piping system on friction support to bi-directional excitation

Response of piping system on friction support to bi-directional excitation Response of piping system on friction support to bi-directional excitation S.V. Bakre a, R.S. Jangid a,, G.R. Reddy b a Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai

More information

Variable friction pendulum system for seismic isolation of liquid storage tanks

Variable friction pendulum system for seismic isolation of liquid storage tanks Variable friction pendulum system for seismic isolation of liquid storage tanks V.R. Panchal 1, R.S. Jangid Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076,

More information

Boundary Nonlinear Dynamic Analysis

Boundary Nonlinear Dynamic Analysis Boundary Nonlinear Dynamic Analysis Damper type Nonlinear Link Base Isolator type Nonlinear Link Modal Nonlinear Analysis : Equivalent Dynamic Load Damper type Nonlinear Link Visco-Elastic Damper (VED)

More information

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane Luan MURTAJ 1, Enkelejda MURTAJ 1 Pedagogue, Department of Structural Mechanics Faculty of Civil Engineering

More information

VARIABLE COEFFICIENT OF FRICTION: AN EFFECTIVE VFPI PARAMETER TO CONTROL NEAR-FAULT GROUND MOTIONS

VARIABLE COEFFICIENT OF FRICTION: AN EFFECTIVE VFPI PARAMETER TO CONTROL NEAR-FAULT GROUND MOTIONS ISET Journal of Earthquake Technology, Paper No. 5, Vol. 49, No. 3-4, Sept.-Dec. 0, pp. 73 87 VARIABLE COEFFICIENT OF FRICTION: AN EFFECTIVE VFPI PARAMETER TO CONTROL NEAR-FAULT GROUND MOTIONS Girish Malu*

More information

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING A COMPUTATIONAL ANALYSIS OF THE FRICTION PENDULUM BASE ISLOATION SYSTEM MATTHEW HEID Spring 2012 A thesis submitted in partial

More information

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 638 INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS Jiachen WANG 1, Athol CARR 1, Nigel

More information

MODELLING OF TRIPLE FRICTION PENDULUM BEARING IN SAP2000

MODELLING OF TRIPLE FRICTION PENDULUM BEARING IN SAP2000 MODELLING OF TRIPLE FRICTION PENDULUM BEARING IN SAP2000 Khloud El-Bayoumi Researcher at Mansoura University, Dept. of Civil Engineering, Faculty of Engineering, Egypt ABSTRACT Until recently there were

More information

Effective Stiffness and Period of Friction Bearing Devices with one Concave Sliding Surface for Different Load Conditions

Effective Stiffness and Period of Friction Bearing Devices with one Concave Sliding Surface for Different Load Conditions ANALELE UNIVERSITĂłII EFTIMIE MURGU REŞIłA ANUL XX, NR. 1, 2013, ISSN 1453-7397 Vasile Iancu, Camelia Ştefania Jurcău, Gilbert-Rainer Gillich Effective Stiffness and Period of Friction Bearing Devices

More information

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3 TABLE OF CONTENTS SECTION TITLE PAGE 1 INTRODUCTION 1 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3 3 ANALYSIS METHODS OF SEISMICALLY ISOLATED BRIDGES 5 3.1 Introduction 5 3.2 Loadings for the Analysis

More information

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE Proceedings of the 8 th U.S. National Conference on Earthquake Engineering April 18-22, 2006, San Francisco, California, USA Paper No. 1954 BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS

More information

Control of Earthquake Induced Vibrations in Asymmetric Buildings Using Passive Damping

Control of Earthquake Induced Vibrations in Asymmetric Buildings Using Passive Damping Control of Earthquake Induced Vibrations in Asymmetric Buildings Using Passive Damping Rakesh K. Goel, California Polytechnic State University, San Luis Obispo Abstract This paper summarizes the results

More information

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM 1NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 1-5, 14 Anchorage, Alaska DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING

More information

NUMERICAL ANALYSIS OF ELEVATED FRAMED STAGING SHALLOW TANK BY NEWMARK S STEP-BY-STEP METHOD

NUMERICAL ANALYSIS OF ELEVATED FRAMED STAGING SHALLOW TANK BY NEWMARK S STEP-BY-STEP METHOD International Journal of Advanced Research in Engineering and Technology (IJARET) Volume 10, Issue 2, March- April 2019, pp. 22-33, Article ID: IJARET_10_02_003 Available online at http://www.iaeme.com/ijaret/issues.asp?jtype=ijaret&vtype=10&itype=02

More information

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION IGC 2009, Guntur, INDIA NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION B. Manna Lecturer, Civil Engineering Department, National Institute of Technology, Rourkela 769008, India.

More information

University of California at Berkeley Structural Engineering Mechanics & Materials Department of Civil & Environmental Engineering Spring 2012 Student name : Doctoral Preliminary Examination in Dynamics

More information

Suhasini N. Madhekar

Suhasini N. Madhekar Seismic Control of Benchmark Highway Bridge Installed with Friction Pendulum System Suhasini N. Madhekar Associate Professor, Applied Mechanics, College of Engineering Pune, Pune 411005, India suhasinimadhekar@gmail.com

More information

Dynamic response of structure with tuned mass friction damper

Dynamic response of structure with tuned mass friction damper Int J Adv Struct Eng (216) 8:363 377 DOI 1.17/s491-16-136-7 ORIGINAL RESEARCH Dynamic response of structure with tuned mass friction damper Alka Y. Pisal 1 R. S. Jangid 2 Received: 5 May 215 / Accepted:

More information

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement A Sloping Surface Roller Bearing and its lateral Stiffness Measurement George C. Lee 1 and Zach Liang Abstract In this paper the laboratory performance and advantages of a new roller-type seismic isolation

More information

Adaptive Behavior of Double Concave Friction Pendulum Bearing and its Advantages over Friction Pendulum Systems

Adaptive Behavior of Double Concave Friction Pendulum Bearing and its Advantages over Friction Pendulum Systems Transaction A: Civil Engineering Vol. 17, No. 2, pp. 81{88 c Sharif University of Technology, April 2010 Adaptive Behavior of Double Concave Friction Pendulum Bearing and its Advantages over Friction Pendulum

More information

SEISMIC BASE ISOLATION

SEISMIC BASE ISOLATION SEISMIC BASE ISOLATION DESIGN OF BASE ISOLATION SYSTEMS IN BUILDINGS FILIPE RIBEIRO DE FIGUEIREDO SUMMARY The current paper aims to present the results of a study for the comparison of different base isolation

More information

INFLUENCE OF FRICTION MODELS ON RESPONSE EVALUATION OF BUILDINGS WITH SLIDING ISOLATION DEVICES

INFLUENCE OF FRICTION MODELS ON RESPONSE EVALUATION OF BUILDINGS WITH SLIDING ISOLATION DEVICES 3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 4 Paper No. 373 INLUENCE O RICTION MODELS ON RESPONSE EVALUATION O BUILDINGS WITH SLIDING ISOLATION DEVICES Sanjaya K.

More information

DEPENDENCE OF ACCIDENTAL TORSION ON STRUCTURAL SYSTEM PROPERTIES

DEPENDENCE OF ACCIDENTAL TORSION ON STRUCTURAL SYSTEM PROPERTIES th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 4 Paper No. 6 DEPENDENCE OF ACCIDENTAL TORSION ON STRUCTURAL SYSTEM PROPERTIES Julio J. HERNÁNDEZ and Oscar A. LÓPEZ SUMMARY

More information

Development of Sloped Rolling-Type Isolation Devices for Seismic Protection of Important Equipment and Facilities

Development of Sloped Rolling-Type Isolation Devices for Seismic Protection of Important Equipment and Facilities Development of Sloped Rolling-Type Isolation Devices for Seismic Protection of Important Equipment and Facilities S.J. Wang, C.H. Yu & J.Y. Hsiao National Center for Research on Earthquake Engineering,

More information

Preliminary Examination - Dynamics

Preliminary Examination - Dynamics Name: University of California, Berkeley Fall Semester, 2018 Problem 1 (30% weight) Preliminary Examination - Dynamics An undamped SDOF system with mass m and stiffness k is initially at rest and is then

More information

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS By S. Jarenprasert 1, E. Bazán -Zurita 2, and J. Bielak 1 1 Department of Civil and Environmental Engineering, Carnegie-Mellon University Pittsburgh,

More information

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES October -7,, Beijing, China A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES Norio HORI, Yoko SAGAMI and Norio INOUE 3 Assistant Professor,

More information

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No.

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No. CHAPTER 5 Question Brief Explanation No. 5.1 From Fig. IBC 1613.5(3) and (4) enlarged region 1 (ASCE 7 Fig. -3 and -4) S S = 1.5g, and S 1 = 0.6g. The g term is already factored in the equations, thus

More information

Mechanical Behavior of Multi-Spherical Sliding Bearings

Mechanical Behavior of Multi-Spherical Sliding Bearings ISSN 50-95X Mechanical Behavior of Multi-Spherical Sliding Bearings by Daniel M. Fenz and Michael C. Constantinou Technical Report MCEER-08-0007 March 6, 008 This research was conducted at the University

More information

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED 4th International Conference on Earthquake Engineering Taipei, Taiwan October 12-13, 2006 Paper No. 224 RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED ON SEISMIC CODES WORLDWIDE Demin Feng 1,

More information

Seismic design of bridges

Seismic design of bridges NAIONAL ECHNICAL UNIVERSIY OF AHENS LABORAORY FOR EARHQUAKE ENGINEERING Seismic design of bridges Lecture 4 Ioannis N. Psycharis Seismic isolation of bridges I. N. Psycharis Seismic design of bridges 2

More information

Embedded Foundation with Different Parameters under Dynamic Excitations

Embedded Foundation with Different Parameters under Dynamic Excitations 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2287 Embedded Foundation with Different Parameters under Dynamic Excitations Jaya K P 1 and Meher Prasad

More information

Numerical Assessment of the Seismic Performance of Sliding Pendulum Isolators

Numerical Assessment of the Seismic Performance of Sliding Pendulum Isolators Numerical Assessment of the Seismic Performance of Sliding Pendulum Isolators E. Gandelli, P. Dubini, M. Bocciarelli & V. Quaglini Politecnico di Milano, Department of Structural Engineering SUMMARY The

More information

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum STRUCTURAL DYNAMICS Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum Overview of Structural Dynamics Structure Members, joints, strength, stiffness, ductility Structure

More information

Codal Provisions IS 1893 (Part 1) 2002

Codal Provisions IS 1893 (Part 1) 2002 Abstract Codal Provisions IS 1893 (Part 1) 00 Paresh V. Patel Assistant Professor, Civil Engineering Department, Nirma Institute of Technology, Ahmedabad 38481 In this article codal provisions of IS 1893

More information

INELASTIC EARTHQUAKE RESPONSE OF BUILDINGS SUBJECTED TO TORSION

INELASTIC EARTHQUAKE RESPONSE OF BUILDINGS SUBJECTED TO TORSION INELASTIC EARTHQUAKE RESPONSE OF BUILDINGS SUBJECTED TO TORSION Kyriakos G STATHOPOULOS 1 And Stavros A ANAGNOSTOPOULOS 2 SUMMARY The inelastic seismic torsional response of simple structures is examined

More information

EVALUATION OF SECOND ORDER EFFECTS ON THE SEISMIC PERFORMANCE OF RC FRAMED STRUCTURES: A FRAGILITY ANALYSIS

EVALUATION OF SECOND ORDER EFFECTS ON THE SEISMIC PERFORMANCE OF RC FRAMED STRUCTURES: A FRAGILITY ANALYSIS 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 428 EVALUATION OF SECOND ORDER EFFECTS ON THE SEISMIC PERFORMANCE OF RC FRAMED STRUCTURES: A FRAGILITY

More information

Preliminary Examination in Dynamics

Preliminary Examination in Dynamics Fall Semester 2017 Problem 1 The simple structure shown below weighs 1,000 kips and has a period of 1.25 sec. It has no viscous damping. It is subjected to the impulsive load shown in the figure. If the

More information

TORSIONAL EFFECTS AND REGULARITY CONDITIONS IN RC BUILDINGS

TORSIONAL EFFECTS AND REGULARITY CONDITIONS IN RC BUILDINGS TORSIONAL EFFECTS AND REGULARITY CONDITIONS IN RC BUILDINGS Edoardo COSENZA 1, Gaetano MANFREDI And Roberto REALFONZO 3 SUMMARY Earthquake damages at the perimeter of buildings are often the result of

More information

STUDY ON PROTECTION MEASURES FOR SEISMIC ISOLATION RUBBER BEARINGS

STUDY ON PROTECTION MEASURES FOR SEISMIC ISOLATION RUBBER BEARINGS ISET Journal of Earthquake Technology, Paper No. 436, Vol. 4, No. -4, June-December 3, pp. 37-6 STUDY ON PROTECTION MEASURES FOR SEISMIC ISOLATION RUBBER BEARINGS Xi-Yuan Zhou*, Miao Han** and Lin Yang***

More information

Improving the earthquake performance of bridges using seismic isolation

Improving the earthquake performance of bridges using seismic isolation Improving the earthquake performance of bridges using seismic isolation Ian Buckle Professor, University of Nevada Reno TRB Webinar February 10, 2016 Sponsored by TRB Committee AFF50: Seismic Design and

More information

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration L. Y. Li & J. P. Ou Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian, 11624, China SUMMARY:

More information

EQUIVALENT DAMPING FORMULATION FOR LRBs TO BE USED IN SIMPLIFIED ANALYSIS OF ISOLATED STRUCTURES

EQUIVALENT DAMPING FORMULATION FOR LRBs TO BE USED IN SIMPLIFIED ANALYSIS OF ISOLATED STRUCTURES Istanbul Bridge Conference August 11-13, 014 Istanbul, Turkey EQUIVALENT DAMPING FORMULATION FOR LRBs TO BE USED IN SIMPLIFIED ANALYSIS OF ISOLATED STRUCTURES G. Özdemir 1 ABSTRACT In this paper, a new

More information

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings. ISSN (Online) 2347-327 Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings. Luan MURTAJ 1, Enkelejda MURTAJ 1 Pedagogue, Department of Structural Mechanics Faculty of

More information

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP,

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP, A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP, Introduction The bulleted enumeration that follows shows five experimental

More information

ESTIMATING PARK-ANG DAMAGE INDEX USING EQUIVALENT SYSTEMS

ESTIMATING PARK-ANG DAMAGE INDEX USING EQUIVALENT SYSTEMS ESTIMATING PARK-ANG DAMAGE INDEX USING EQUIVALENT SYSTEMS Debarati Datta 1 and Siddhartha Ghosh 2 1 Research Scholar, Department of Civil Engineering, Indian Institute of Technology Bombay, India 2 Assistant

More information

EUROCODE EN SEISMIC DESIGN OF BRIDGES

EUROCODE EN SEISMIC DESIGN OF BRIDGES Brussels, 18-20 February 2008 Dissemination of information workshop 1 EUROCODE EN1998-2 SEISMIC DESIGN OF BRIDGES Basil Kolias Basic Requirements Brussels, 18-20 February 2008 Dissemination of information

More information

Static & Dynamic. Analysis of Structures. Edward L.Wilson. University of California, Berkeley. Fourth Edition. Professor Emeritus of Civil Engineering

Static & Dynamic. Analysis of Structures. Edward L.Wilson. University of California, Berkeley. Fourth Edition. Professor Emeritus of Civil Engineering Static & Dynamic Analysis of Structures A Physical Approach With Emphasis on Earthquake Engineering Edward LWilson Professor Emeritus of Civil Engineering University of California, Berkeley Fourth Edition

More information

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns A. Chen, J.O.C. Lo, C-L. Lee, G.A. MacRae & T.Z. Yeow Department of Civil Engineering, University of Canterbury,

More information

EFFECTS OF RESERVOIR LENGTH ON DYNAMIC ANALYSIS OF CONCRETE GRAVITY DAMS

EFFECTS OF RESERVOIR LENGTH ON DYNAMIC ANALYSIS OF CONCRETE GRAVITY DAMS The th October -,, Beijing, China EFFECTS OF RESERVOIR LENGTH ON DYNAMIC ANALYSIS OF CONCRETE GRAVITY DAMS A. Fathi and V. Lotfi M.Sc. Student, Dept. of Civil and Environmental Engineering, Amirkabir University

More information

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings Fawad A. Najam Pennung Warnitchai Asian Institute of Technology (AIT), Thailand Email: fawad.ahmed.najam@ait.ac.th A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic

More information

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS Title ANALYSIS OF SHAKE-TABLE TESTS OF A FULL-SCALE BUILDI BEAINGS Author(s)DONG, Q.; OKAZAKI, T.; MIDOIKAWA, M.; YAN, K.; SAT Issue Date -9- Doc UL http://hdl.handle.net// Type proceedings Note The Thirteenth

More information

Effect of Dampers on Seismic Demand of Short Period Structures

Effect of Dampers on Seismic Demand of Short Period Structures Effect of Dampers on Seismic Demand of Short Period Structures Associate Professor of Civil Engineering, University of Jordan. Email: armouti@ju.edu.jo ABSTRACT Seismic behavior of a single bay frame with

More information

18. FAST NONLINEAR ANALYSIS. The Dynamic Analysis of a Structure with a Small Number of Nonlinear Elements is Almost as Fast as a Linear Analysis

18. FAST NONLINEAR ANALYSIS. The Dynamic Analysis of a Structure with a Small Number of Nonlinear Elements is Almost as Fast as a Linear Analysis 18. FAS NONLINEAR ANALYSIS he Dynamic Analysis of a Structure with a Small Number of Nonlinear Elements is Almost as Fast as a Linear Analysis 18.1 INRODUCION he response of real structures when subjected

More information

THEORY OF VIBRATION ISOLATION

THEORY OF VIBRATION ISOLATION CHAPTER 30 THEORY OF VIBRATION ISOLATION Charles E. Crede Jerome E. Ruzicka INTRODUCTION Vibration isolation concerns means to bring about a reduction in a vibratory effect. A vibration isolator in its

More information

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS Christoph ADAM 1 And Peter A FOTIU 2 SUMMARY The objective of the paper is to investigate numerically the effect of ductile material

More information

SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT BUILDINGS

SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT BUILDINGS 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 1918 SHAKE TABLE STUDY OF SOIL STRUCTURE INTERACTION EFFECTS ON SEISMIC RESPONSE OF SINGLE AND ADJACENT

More information

Dynamic Analysis Using Response Spectrum Seismic Loading

Dynamic Analysis Using Response Spectrum Seismic Loading Dynamic Analysis Using Response Spectrum Seismic Loading Paleti Teja M.Tech (Structural Engineering) Department of Civil Engineering Jogaiah Institute of Technology & Sciences College of Engineering Kalagampudi,

More information

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, Paper No. 6 COLUMN INTERACTION EFFECT ON PUSH OVER D ANALYSIS OF IRREGULAR STRUCTURES Jaime DE-LA-COLINA, MariCarmen HERNANDEZ

More information

Displacement ductility demand and strength reduction factors for rocking structures

Displacement ductility demand and strength reduction factors for rocking structures Earthquake Resistant Engineering Structures VI 9 Displacement ductility demand and strength reduction factors for rocking structures M. Trueb, Y. Belmouden & P. Lestuzzi ETHZ-Swiss Federal Institute of

More information

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems American Journal of Applied Sciences Original Research Paper The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems 1 Ahmad N. Tarawneh,

More information

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS A. Samanta 1 and P. Banerji 2 1 Research Scholar, Department of Civil Engineering, Indian Institute of Technology Bombay, Mumbai, India, 2 Professor,

More information

KINEMATIC RESPONSE OF GROUPS WITH INCLINED PILES

KINEMATIC RESPONSE OF GROUPS WITH INCLINED PILES th International Conference on Earthquake Geotechnical Engineering June 5-8, 7 Paper No. 5 KINEMATIC RESPONSE OF GROUPS WITH INCLINED PILES Amalia GIANNAKOU, Nikos GEROLYMOS, and George GAZETAS 3 ABSTRACT

More information

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS 3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 4 Paper No. 377 SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS Ramiro VARGAS and Michel BRUNEAU

More information

RESPONSE SPECTRUM METHOD FOR ESTIMATION OF PEAK FLOOR ACCELERATION DEMAND

RESPONSE SPECTRUM METHOD FOR ESTIMATION OF PEAK FLOOR ACCELERATION DEMAND RESPONSE SPECTRUM METHOD FOR ESTIMATION OF PEAK FLOOR ACCELERATION DEMAND Shahram Taghavi 1 and Eduardo Miranda 2 1 Senior catastrophe risk modeler, Risk Management Solutions, CA, USA 2 Associate Professor,

More information

Structural behavior of a high-rise RC structure under vertical earthquake motion

Structural behavior of a high-rise RC structure under vertical earthquake motion Structural behavior of a high-rise RC structure under vertical earthquake motion Selcuk Bas 1), Ilker Kalkan 2) and *Jong-Han Lee 3) 1) Department of Civil Engineering, Bartin University, 74100 Central,

More information

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil Fang Ming Scholl of Civil Engineering, Harbin Institute of Technology, China Wang Tao Institute of

More information

Final Exam Solution Dynamics :45 12:15. Problem 1 Bateau

Final Exam Solution Dynamics :45 12:15. Problem 1 Bateau Final Exam Solution Dynamics 2 191157140 31-01-2013 8:45 12:15 Problem 1 Bateau Bateau is a trapeze act by Cirque du Soleil in which artists perform aerial maneuvers on a boat shaped structure. The boat

More information

VERIFYING THE LOCATION OF THE OPTIMUM TORSION AXIS OF MULTI-STORY BUILDINGS USING DYNAMIC ANALYSIS

VERIFYING THE LOCATION OF THE OPTIMUM TORSION AXIS OF MULTI-STORY BUILDINGS USING DYNAMIC ANALYSIS 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 004 Paper No. 833 VERIFYING THE LOCATION OF THE OPTIMUM TORSION AXIS OF MULTI-STORY BUILDINGS USING DYNAMIC ANALYSIS

More information

ENVELOPES FOR SEISMIC RESPONSE VECTORS IN NONLINEAR STRUCTURES

ENVELOPES FOR SEISMIC RESPONSE VECTORS IN NONLINEAR STRUCTURES ENVEOPES FOR SEISMIC RESPONSE VECTORS IN NONINEAR STRUCTURES Charles MENUN And Armen DER KIUREGHIAN SUMMARY In earthquake engineering, the effects of responses acting simultaneously in a structure must

More information

KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR

KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2 Paper No. 99 KINETIC EEFCT ON FLEXIBLE BODIES BEHAVIOR Eduardo BOTERO 1 and Miguel P. ROMO 2 SUMMARY When a flexible

More information

Seismic performance and effect of curved geometry on isolation system in horizontally curved bridge

Seismic performance and effect of curved geometry on isolation system in horizontally curved bridge Seismic performance and effect of curved geometry on isolation system in horizontally curved ridge *Nitin P. Kataria 1) and R. S. Jangid 2) 1), 2) Department of Civil Engineering, Indian Institute of Technology

More information

Some Aspects of Structural Dynamics

Some Aspects of Structural Dynamics Appendix B Some Aspects of Structural Dynamics This Appendix deals with some aspects of the dynamic behavior of SDOF and MDOF. It starts with the formulation of the equation of motion of SDOF systems.

More information

Performance Estimates for Seismically Isolated Bridges

Performance Estimates for Seismically Isolated Bridges ISSN 152-295X Performance Estimates for Seismically Isolated Bridges by Gordon P. Warn and Andrew S. Whittaker Technical Report MCEER-7-24 December 3, 27 This research was conducted at the University at

More information

STUDY ON THE BI-NORMALIZED EARTHQUAKE ACCELERATION RESPONSE SPECTRA

STUDY ON THE BI-NORMALIZED EARTHQUAKE ACCELERATION RESPONSE SPECTRA th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, Paper No. 59 STUDY ON THE BI-NORMALIZED EARTHQUAKE ACCELERATION RESPONSE SPECTRA XU Longjun, XIE Lili, SUMMARY The determination

More information

Structural Damage Detection Using Time Windowing Technique from Measured Acceleration during Earthquake

Structural Damage Detection Using Time Windowing Technique from Measured Acceleration during Earthquake Structural Damage Detection Using Time Windowing Technique from Measured Acceleration during Earthquake Seung Keun Park and Hae Sung Lee ABSTRACT This paper presents a system identification (SI) scheme

More information

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION INEASTIC SEISMIC DISPACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVAENT INEARIZATION M. S. Günay 1 and H. Sucuoğlu 1 Research Assistant, Dept. of Civil Engineering, Middle East Technical University,

More information

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in Sabah Shawkat Cabinet of Structural Engineering 17 3.6 Shear walls Walls carrying vertical loads should be designed as columns. Basically walls are designed in the same manner as columns, but there are

More information

Analytical Predictive Models for Lead-Core and Elastomeric Bearing

Analytical Predictive Models for Lead-Core and Elastomeric Bearing Journal of Civil Engineering and Architecture (07) 748-756 doi: 0.765/934-7359/07.08.003 D DAVID PUBLISHING Analytical Predictive Models for Lead-Core and Elastomeric Bearing Todor Zhelyazov Technical

More information

Wire rope springs for passive vibration control of a light steel structure

Wire rope springs for passive vibration control of a light steel structure Wire rope springs for passive vibration control of a light steel structure STEFANO PAGANO, SALVATORE STRANO Dipartimento di Ingegneria Industriale Università degli Studi di Napoli Federico II Via Claudio

More information

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS 7 Hirokazu SHIMODA, Norio NAGAI, Haruo SHIMOSAKA And Kenichiro OHMATA 4 SUMMARY In this study, a new type of isolation

More information

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2 1) A two-story building frame is shown below. The mass of the frame is assumed to be lumped at the floor levels and the floor slabs are considered rigid. The floor masses and the story stiffnesses are

More information

THREE-DIMENSIONAL NONLINEAR DEGRADING MODEL FOR EARTHQUAKE RESPONSE ANALYSES OF CONCRETE BRIDGES

THREE-DIMENSIONAL NONLINEAR DEGRADING MODEL FOR EARTHQUAKE RESPONSE ANALYSES OF CONCRETE BRIDGES The 4 th World Conference on Earthquake Engineering October 2-7, 28, Beijing, China THREE-DIMENSIONAL NONLINEAR DEGRADING MODEL FOR EARTHQUAKE RESPONSE ANALYSES OF CONCRETE BRIDGES V. Phung and D. Lau

More information

GROUND MOTION DOMINANT FREQUENCY EFFECT ON THE DESIGN OF MULTIPLE TUNED MASS DAMPERS

GROUND MOTION DOMINANT FREQUENCY EFFECT ON THE DESIGN OF MULTIPLE TUNED MASS DAMPERS Journal of Earthquake Engineering, Vol. 8, No. 1 (2004) 89 105 c Imperial College Press GROUND MOTION DOMINANT FREQUENCY EFFECT ON THE DESIGN OF MULTIPLE TUNED MASS DAMPERS CHUNXIANG LI School of Civil

More information

Introduction to structural dynamics

Introduction to structural dynamics Introduction to structural dynamics p n m n u n p n-1 p 3... m n-1 m 3... u n-1 u 3 k 1 c 1 u 1 u 2 k 2 m p 1 1 c 2 m2 p 2 k n c n m n u n p n m 2 p 2 u 2 m 1 p 1 u 1 Static vs dynamic analysis Static

More information

Vibration Control of Building Subjected to Harmonic Excitation

Vibration Control of Building Subjected to Harmonic Excitation Kalpa Publications in Civil Engineering Volume 1, 2017, Pages 363 368 ICRISET2017. International Conference on Research and Innovations in Science, Engineering &Technology. Selected papers in Civil Engineering

More information

Experimental and Analytical Study of the XY-Friction Pendulum (XY-FP) Bearing for Bridge Applications

Experimental and Analytical Study of the XY-Friction Pendulum (XY-FP) Bearing for Bridge Applications ISSN 1520-295X Experimental and Analytical Study of the XY-Friction Pendulum (XY-FP) Bearing for Bridge Applications by Claudia C. Marin-Artieda, Andrew S. Whittaker and Michael C. Constantinou Technical

More information

COMPARISON OF LABVIEW WITH SAP2000 AND NONLIN FOR STRUCTURAL DYNAMICS PROBLEMS

COMPARISON OF LABVIEW WITH SAP2000 AND NONLIN FOR STRUCTURAL DYNAMICS PROBLEMS International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue 2, February 2017, pp. 226 235 Article ID: IJCIET_08_02_025 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=8&itype=2

More information