1 Circulation pumps Wet rotor circulators and accessories CATALOGUE eating, air-conditioning, solar, domestic water

2 alm produces highly-efficient heating circulation pumps alm has been successfully developing and producing heating circulation pumps for over years. It started out manufacturing for renowned OEM customers before electing to develop and produce its own product range in the late 99s. Its proficiency in the development of innovative, market-oriented products is first and foremost reflected in the more than half a century of company history. Today, in the second generation, the circulation pumps segment plays a major part in the success of the company. This is particularly evident in the high level of creative innovation in recent years, with many new products in the field of high-efficiency pumps. alm is helping to shape the future as a reliable partner A company is only as good as each of its constituent parts. This is why motivated and experienced employees are a key element of success at alm. Flexibility and expertise head the list of priorities for being a reliable partner to our customers. Together with over employees, alm s objective is to make a lasting contribution to the future with its products. alm high efficiency pumps already fulfil the tightened requirements of the eco-design directive from until. alm places great demand on the quality of its products Modern production facilities and processes are just as much part of the corporate concept as well thought-out quality management. Internal testing facilities and ISOcertified quality management are indispensible factors of success. Long-standing customers value the high demands placed on the quality of the products and the flexibility with which alm meets custom requirements UPA UE EP EP Plus EP Plus (N) EP BB EPL

3 Contents Catalogue valid for EU countries + others ) I. Product range Page Contact General information Circulation pumps with screw connection EP Plus: igh efficiency pumps with LED display, electronically controlled 6 EP Plus (N): igh efficiency pumps with LED display and stainless steel housing, electronically controlled 8 EP: igh efficiency pumps, electronically controlled UPA-Solar: Standard solar pumps, speed step switch (-step) GPA-Solar: Solar pumps, speed step switch (-step), pressure head 7- m LPA-Solar: Solar pumps, speed step switch (-step) 6 BUPA: Standard circulation pumps for domestic water 8 BGPA: Circulation pumps for domestic water, pressure head 7- m KGPA: Cold water circulation pumps (geothermy and refrigeration), pressure head 7- m Accessories Z: Terminal plug for circulation pumps Insulation shell II. Replacement lists Circulation pumps with screw connection EP Plus: igh efficiency pumps with LED display, electronically controlled EP Plus (N): igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP: igh efficiency pumps, electronically controlled UPA: Standard circualation pumps (from.. no longer available in the EU) 6 UPA-Solar: Standard solar pumps, speed step switch (-step) 7 BUPA: Standard circulation pumps for domestic water 7 KGPA: Cold water circulation pumps (geothermy and refrigeration), pressure head 7- m 8 ) EFTA (Iceland, Liechtenstein, Norway), Croatia, Switzerland, autonomic areas of EU member states (Faroe Islands, Jersey, Isle of Man, Guernsey, Greenland), Andorra, Monaco, San Marino. Subject to technical changes without notice. Errors and ommissions excepted. The latest versions of our sales, delivery, and payment conditions as well as guarantee terms can be found on the internet at

4 Contact at alm: Sales Mr Robin Pomreinke Phone: +9 ()7 9- Fax: +9 ()7 9- Order management Ms annelore Tomani Phone: +9 ()7 9- Fax: +9 ()7 968 Ms Sabrina Wagner Phone: +9 () Fax: +9 ()7 968 After Sales Mr Thomas Müller Phone: +9 ()7 9- Fax: +9 ()7 968 Service hotline Tel: +9 ()7 9-6

5 General information alm type key EP -. E 8 Pump types Nominal width pipe connection Pressure head in meters water column Speed switchable or electronically controlled Installation length (mm) Installation options Circulation pumps must be installed with a horizontal shaft. Construction alm circulation pumps are inline wet rotor circulators. They are maintenance-free and fitted with opposite-facing connecting nozzles of the same nominal width. The pump, motor and terminal box comprise one unit and are optimally matched with one another. A stainless steel can separates the rotor chamber and stator winding. It features static seals at both ends. Bearing Both bearings are made of oxide ceramic. This is particularly suitable because of its hardness, surface quality and corrosion resistance. They ensure smooth running and a long service life. Air cavities in the can well are evacuated via the hollow shaft. EEI The benchmark of the most efficient circulators is EEI.. All alm m high efficiency pumps fulfill the requirements for BEST in class.

6 igh efficiency pumps with LED display, electronically controlled EP Plus series, P product group Insulation shell With installation length 8 mm included in delivery. See also page. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s operating data must be checked above % glycol Rate of flow: up to. m / h Pressure head: m / 6 m / 7 m Control range: - W / - W / -66 W Media temperature: + C to +9 C Installation length: and 8 mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: p or fixed rpm EEI:. EP Plus XX-. EXXX. EP Plus XX-6. EXXX.7 EP Plus XX-7. EXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation Use The electronically controlled EP Plus high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in heating systems close, the volume flow drops. This results in slight pipe resistance. The declining flow rate means that the circulation pump requires a lower pressure head. This is identified by the automatic control of the circulation pump. It automatically adjusts to the system and reduces its performance. This leads to not only trouble-free and quiet operation but also reduces energy consumption to a minimum. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler / primary circuit storage charging circuit solar systems and heating pumps * valid for all EP Plus m pumps space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted, screwable angle entry-plug compact design Materials Component Material Material no. * Temperature range Ambient temperature: C to + C Temperature class: TF 9 Media temperature: + C to +9 C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve ). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 7 C > 9 C Minimum inflow pressure. bar.8 bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic The control characteristics and the fixed speed steps can be adjusted continuously variable via the potentiometer on the axial terminal box. At the factory settings the potentiometer is in the centre position. This position corresponds to the reference characteristic curve with optimal efficiency. If noises are heard in this position, the characteristic curve can be adjusted by turning the potentiometer clockwise. If the pressure head is not sufficient (some radiators remain cold despite hydraulic equalisation), the characteristic curve can be corrected upwards. EP...-.-E Pump housing Grey-cast iron.6 Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel MAX fix MAX p Q (m / h)

7 igh efficiency pumps with LED display, electronically controlled EP Plus series, P product group Type EP Plus -. E EP Plus -6. E EP Plus -7. E EP Plus -. E EP Plus -6. E EP Plus -7. E EP Plus -. E EP Plus -6. E EP Plus -7. E EP Plus -. E 8 EP Plus -6. E 8 EP Plus -7. E 8 EP Plus -. E 8 EP Plus -6. E 8 EP Plus -7. E 8 Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI ½ ½ ½ ¾ ¼ ¾ ¼ ¾ ¼ ½ ½ ½ ½ ½ ½ ¼ ¼ ¼ MAX fix MAX p EP...-.-E Q (m / h) MAX fix 6... MAX p EP E Q (m / h) MAX EP...7.-E fix 7. MAX 6. p Q (m³ / h) P (W) MAX fix MAX p EP...-.-E Q (m / h) P (W) 6 MAX p MAX fix EP E.. Q (m / h) P (W) 7 6 MAX fix MAX p EP...7.-E Q (m³ / h) Dimensions Type L L L L EP Plus / Dimension illustration G L L L L 7

8 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Plus (N) series, P product group Insulation shell With installation length 8 mm included in delivery. See also page. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s operating data must be checked above % glycol Rate of flow: up to. m / h Pressure head: m / 6 m Control range: - W / - W Media temperature: + C to +9 C Installation length:, and 8 mm Threaded connection: and ½ Protection class: IP Insulation class: F Nominal pressure: PN Control: p or fixed rpm EEI:. EP Plus (N) XX-. EXXX. EP Plus (N) XX-6. EXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation Use The electronically controlled EP Plus (N) high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems as well as drinking water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in heating systems close, the volume flow drops. This results in slight pipe resistance. The declining flow rate means that the circulation pump requires a lower pressure head. This is identified by the automatic control of the circulation pump. It automatically adjusts to the system and reduces its performance. This leads to not only trouble-free and quiet operation but also reduces energy consumption to a minimum. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler / primary circuit storage charging circuit solar systems and heating pumps * * valid for all EP Plus (N) m pumps space-saving axially integrated terminal box automatic adjustment to pressure conditions stainless steel pump housing pre-mounted, screwable angle entry-plug compact design Temperature range Ambient temperature: C to + C Temperature class: TF 9 Media temperature: + C to +9 C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve ). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 7 C > 9 C Minimum inflow pressure. bar.8 bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic The control characteristics and the fixed speed steps can be adjusted continuously variable via the potentiometer on the axial terminal box. At the factory settings the potentiometer is in the centre position. This position corresponds to the reference characteristic curve with optimal efficiency. If noises are heard in this position, the characteristic curve can be adjusted by turning the potentiometer clockwise. If the pressure head is not sufficient (some radiators remain cold despite hydraulic equalisation), the characteristic curve can be corrected upwards. and drinking water systems in building and industry installations as circulation circuit storage charging circuit cooling and heating circuit underfloor heating EP...-.-E 8 Materials Component Material Material no. Pump housing Stainless steel.8 Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel MAX fix MAX p Q (m / h)

9 igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Plus (N) series, P product group Type EP Plus (N) -. E EP Plus (N) -6. E EP Plus (N) -. E EP Plus (N) -6. E EP Plus (N) -. E 8 EP Plus (N) -6. E 8 Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI ½ ½ ¾ ¼.,7 -.. ¾ ¼.6,7-6.. ½ ½ MAX fix MAX p EP...-.-E Q (m / h) MAX fix MAX p EP E Q (m / h) P (W) MAX fix MAX p EP...-.-E P (W) 6 MAX p MAX fix EP E Q (m / h) Q (m / h) Dimensions Type L L L L EP Plus (N) / / Dimension illustration G L L L L 9

10 igh efficiency pumps, electronically controlled EP series, P product group Insulation shell With installation length 8 mm included in delivery. See also page. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s operating data must be checked above % glycol Rate of flow: up to. m / h Pressure head: m / 6 m Control range: - W / - W Media temperature: + C to +9 C Installation length: and 8 mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: p or fixed rpm EEI:. EP XX-. EXXX. EP XX-6. EXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation space-saving axially integrated terminal box Use The electronically controlled EP high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in heating systems close, the volume flow drops. This results in slight pipe resistance. The declining flow rate means that the circulation pump requires a lower pressure head. This is identified by the automatic control of the circulation pump. It automatically adjusts to the system and reduces its performance. This leads to not only trouble-free and quiet operation but also reduces energy consumption to a minimum. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler / primary circuit storage charging circuit solar systems and heating pumps * valid for all EP m pumps automatic adjustment to pressure conditions cataphorectic coated pump housing pre-mounted, screwable angle entry-plug compact design * Temperature range Ambient temperature: C to + C Temperature class: TF 9 Media temperature: + C to +9 C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve ). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 7 C > 9 C Minimum inflow pressure. bar.8 bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic The control characteristics and the fixed speed steps can be adjusted continuously variable via the potentiometer on the axial terminal box. At the factory settings the potentiometer is in the centre position. This position corresponds to the reference characteristic curve with optimal efficiency. If noises are heard in this position, the characteristic curve can be adjusted by turning the potentiometer clockwise. If the pressure head is not sufficient (some radiators remain cold despite hydraulic equalisation), the characteristic curve can be corrected upwards. Materials Component Material Material no. EP...-.-E Pump housing Grey-cast iron.6 Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel MAX fix MAX p Q (m / h)......

11 igh efficiency pumps, electronically controlled EP series, P product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP -. E ½ EP -6. E ½ EP -. E ¾ ¼ EP -6. E ¾ ¼ EP -. E ½ EP -6. E ½ EP -. E 8 ½ EP -6. E 8 ½ EP -. E 8 ¼ EP -6. E 8 ¼ MAX fix MAX p EP...-.-E Q (m / h) MAX fix MAX p EP E Q (m / h) P (W) MAX fix MAX p EP...-.-E P (W) 6 MAX p MAX fix EP E Q (m / h) Q (m / h) Dimensions Type L L L L EP / Dimension illustration G L L L L

12 Standard solar pumps, speed step switch (-step) UPA-Solar series, product group Series UPA-Solar must only be used in the European Union in primary circuits of solar thermal systems. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C (short-term up to C) Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Rate of flow: up to.8 m / h Pressure head: up to 7. m Media temperature: + C to + C (short-term up to C) Installation length: and 8 mm Threaded connection:, ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature energy-optimised space-saving axially integrated terminal box cataphorectic coated pump housing Use The UPA solar pumps are wet rotor circulators designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron.6 Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A)

13 Standard solar pumps, speed step switch (-step) UPA-Solar series, product group Type UPA-Solar -. U UPA-Solar -7. U UPA-Solar -. U UPA-Solar -7. U UPA-Solar -. U UPA-Solar -7. U UPA-Solar -. U 8 UPA-Solar -7. U 8 UPA-Solar -. U 8 UPA-Solar -7. U 8 Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. ½ ½ ¾ ¼ ¾ ¼ ½ ½ ½ ½ ¼ ¼ UPA...-. U 7. UPA U Q (m / h) Q (m / h) Dimensions Type L L L L UPA-Solar / Dimension illustration G L L L L

14 Solar pumps, speed step switch (-step), pressure head 7- m GPA-Solar series, G product group Series GPA-Solar must only be used in the European Union in primary circuits of solar thermal systems. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Rate of flow: up to m / h Pressure head: up to m Media temperature: + C to + C Installation length: 8 mm Threaded connection: ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The GPA-Solar circulation pump from alm is a wet rotor circulator and specially designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron.6 Impeller Polypropylene (PP - GF ) Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a -step rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Shaft Bearing Bearing plate Brass. Can Stainless steel.

15 Solar pumps, speed step switch (-step), pressure head 7- m GPA-Solar series, G product group Type GPA-Solar -8. U 8 GPA-Solar -. U 8 GPA-Solar -. U 8 GPA-Solar -8. U 8 GPA-Solar -. U 8 GPA-Solar -. U 8 Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. ½ ½ ½ ¼ ¼ ¼ GPA U Q (m / h) GPA...-. U Q (m / h) GPA...-. U Q (m / h) Dimensions Type L L L L GPA-Solar Dimension illustration G L L L L

16 Solar pumps, speed step switch (-step) LPA-Solar series, product group Series LPA-Solar must only be used in the European Union in primary circuits of solar thermal systems. Flow media heating water pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid particles or fibres media with a max. viscosity of,8 - ft /s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Rate of flow: up to 7 m / h Pressure head: up to 7 m Media temperature: - C to + C Installation lenght: 8 mm Threaded connection: ½ und Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature smooth running convenient operation space-saving axially integrated terminal box compact design Use The LPA-Solar circulation pump from alm is a wet rotor circulator and specially designed for primary circuits of solar systems. Materials Component Material Material no. Pump housing Grey-cast iron.6 Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching Three speed, with manual selector. The respective speed is set via a -step rotary switch integrated in the terminal board. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) 6

17 Solar pumps, speed step switch (-step) LPA-Solar series, product group Type LPA-Solar -7. U 8 LPA-Solar -7. U 8 Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. ½ ¼ LPA U,, 6, 8, Q (m / h) Dimensions Type L L L L LPA-Solar Dimension illustration 7

18 Standard circulation pumps for domestic water BUPA series, B product group From.. the BUPA series must only be used in the European Union as circulation pump in drinking water systems in compliance with DIN 98/8/EG. Flow media drinking water and heated drinking water to a temperature of 6 C and a degree of hardness of d (temporary hardness) pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Rate of flow: up to. m / h Pressure head: up to 6 m Media temperature: + C to + C Installation length:, and 8 mm Threaded connection:, ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box Use The BUPA series circulation pumps are wet rotor circulators designed for use in drinking water systems with constant or weakly variable flow rates. They feature a corrosionresistant pump housing in bronze and are thus suitable for use in drinking water circulation systems. Materials Component Material Material no. Pump housing Bronze (RG ).96 (low-lead) Impeller PSU - GF Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure at corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) 8

19 Standard circulation pumps for domestic water BUPA series, B product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BUPA -. U ½ BUPA -. U ½ BUPA -. U ½ BUPA -6. U ½ BUPA -. U ¾ ¼ BUPA -. U ¾ ¼ BUPA -. U ¾ ¼ BUPA -6. U ¾ ¼ BUPA -. U ½ BUPA -. U ½ BUPA -. U ½ BUPA -6. U ½ BUPA -. U 8 ½ BUPA -. U 8 ½ BUPA -. U 8 ½ BUPA -6. U 8 ½ BUPA...-. U BUPA...-. U Q (m / h) Q (m / h) BUPA...-. U 7 6 BUPA U Q (m / h) Q (m / h) Dimensions Dimension illustration G Type L L L L BUPA / / L L L L 9

20 Circulation pumps for domestic water, pressure head 7- m BGPA series, BG product group From.. the BGPA series must only be used in the European Union as circulation pump in drinking water systems in compliance with DIN 98/8/EG. Flow media drinking water and heated drinking water to a temperature of 6 C and a degree of hardness of d (temporary hardness) pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Rate of flow: up to. m / h Pressure head: up to m Media temperature: + C to + C Installation length: 8 mm Threaded connection: ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box pump housing in bronze Use The BGPA series circulation pumps are wet rotor circulators designed for use in drinking water systems with a flow rate of > m / h. They feature a corrosion-resistant housing in bronze and are thus designed for use in drinking water circulation systems. Materials Component Material Material no. Pump housing Bronze (RG ).96 (low-lead) Impeller Polypropylene (PP - GF ) Shaft Bearing Bearing plate Brass. Can Stainless steel. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A)

21 Circulation pumps for domestic water, pressure head 7- m BGPA series, BG product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BGPA -7. U 8 ¾ ¼ BGPA -8. U 8 ¾ ¼ BGPA -. U 8 ¾ ¼ BGPA -. U 8 ¾ ¼ BGPA -7. U 8 ½ BGPA -8. U 8 ½ BGPA -. U 8 ½ BGPA -. U 8 ½ BGPA U Q (m / h) BGPA U Q (m / h) BGPA...-. U Q (m / h) BGPA...-. U Q (m / h) Dimensions Type L L L L BGPA 8, 66 6 Dimension illustration G L L L L

22 Cold water circulation pumps (geothermy), pressure head 7- m KGPA series, KG product group From.. the KGPA series must only be used in the European Union in primary circuit of heat pumps (brine side). Flow media pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm² / s Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Motor protection External motor protection is not required. Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Rate of flow: up to. m / h Pressure head: up to m Media temperature: - C to + C Installation length: 8 mm Threaded connection: ½ and Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < 8 C 9 C C Minimum inflow pressure. bar. bar. bar Sound pressure level The sound pressure level is < db (A) Product features manual start-up feature space-saving axially integrated terminal box cataphorectic coated pump housing Use The KGPA series circulation pumps are wet rotor circulators designed for use in primary circuit of heat pumps (brine side) with a flow rate of > m / h. They feature an housing resistant to corrosion with KTL coating and a sealed motor winding. On request, pumps from the KGPA series are also available with a bronze housing (KGPB). Materials Component Material Material no. Pump housing Grey-cast iron.6 Impeller Polypropylene (PP - GF ) Shaft Bearing Bearing plate Brass. Can Stainless steel.

23 Cold water circulation pumps (geothermy), pressure head 7- m KGPA series, KG product group Type * Also available with DN Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. *KGPA -7. U 8 ½ *KGPA -8. U 8 ½ *KGPA -. U 8 ½ *KGPA -. U 8 ½ *KGPA -7. U 8 ¼ *KGPA -8. U 8 ¼ *KGPA -. U 8 ¼ *KGPA -. U 8 ¼ KGPA U Q (m / h) KGPA U Q (m / h) KGPA...-. U Q (m / h) KGPA...-. U Q (m / h) Dimensions Type L L L L KGPA Dimension illustration G L L L L

24 Accessories Z product group Plugs for screw pumps ("plug & pump") - screwable universal plug complete with motor connection / socket only - for universal use with all alm screw pumps - for simple and quick connection Description Product no. Plug complete 9-- Socket only 9- Insulation shell For product groups P / in installation length 8 mm Description Product no. Insulation shell - Further accessories on request. Sample

25 Replacement lists Grundfos - Wilo - KSB - Biral - DAB - ITT Lowara - alm P product group EP series, EP Plus series Grundfos Wilo KSB Biral DAB Xylem / ITT Lowara alm Product no. Alpha - Alpha L - Alpha Pro - Yonos Pico /-6 Stratos Pico /- - AX - - EA -/ EV -/ EP -. E EP Plus -. E Alpha -6 Alpha L -6 Alpha Pro -6 Yonos Pico /-6 Stratos Pico /- - AX - - EA -6/ EV -6/ EP -6. E EP Plus -6. E EP Plus -7. E Star - E/- - - VEA / M EV+/EA+ / EP -. E EP Plus -. E Star - E/- - - VEA 6/ M EV+/EA+ 6/ EP -6. E EP Plus -6. E EP Plus -7. E -7. Alpha - Alpha L - Alpha Pro - Yonos Pico /- Stratos Pico /- - AX - - EA -/ EV -/ EP -. E EP Plus -. E Alpha - * Alpha L - * Alpha -6 Alpha L -6 Alpha Pro -6 Yonos Pico /-6 Stratos Pico /-6 - AX - - EA -6/ EV -6/ EP -6. E EP Plus -6. E EP Plus -7. E -7. Alpha - Alpha L - Alpha Pro - Yonos Pico /- Stratos Pico /- Stratos Eco /--BMS Riotronic P - Riotronic Eco - AX - AC /8M EA -/8 EV -/8 EP -. E 8 EP Plus -. E Alpha -6 Alpha L -6 Alpha Pro -6L Yonos Pico /-6 Stratos Pico /-6 Stratos Eco /--BMS Riotronic P -6 Riotronic Eco -6 AX - AC /8M EA -6/8 EV -6/8 EP -6. E 8 EP Plus -6. E EP Plus -7. E8-7. Alpha - Alpha L - Alpha Pro - Yonos Pico /- Stratos Pico /- Stratos Eco /--BMS Riotronic P - Riotronic Eco - AX - AC /8X EA -/8 EV -/8 EP -. E 8 EP Plus -. E Alpha -6 Alpha L -6 Alpha Pro -6 Yonos Pico /- 6 Stratos Pico /-6 Stratos Eco /--BMS Riotronic P -6 Riotronic Eco -6 AX - AC /8X EA -6/8 EV -6/8 EP -6. E 8 EP Plus -6. E EP Plus -7. E8-7. P product group EP Plus (N) series Grundfos Wilo KSB Biral DAB Xylem / ITT Lowara alm Product no. * UK only UP -BX TLCB -.// EP Plus (N) -. E TLCB -6 EP Plus (N) -6. E -6. UP - N Alpha - N Star Z / Riotherm C TLCB -M EP Plus (N) -. E -. UPS -6 N Alpha -6 N TLCB -6M EP Plus (N) -6. E -6. UPS - N 8 UPE - N Alpha - N 8 Star Z / Stratos Eco-Z /- Riotherm C - AXW - (/8mm) VS / TLCB -L EP Plus (N) -. E 8 -. UPS -6/ N 8 UPE -6 N 8 Alpha -6 N 8 Star Z /6 Stratos Eco-Z /- Riotherm C -6 AXW - (/8mm) VS 6/ TLCB -6L EP Plus (N) -6. E 8-6.

26 Replacement lists Grundfos - Wilo - KSB - Biral - DAB - Speck - alm product group UPA series Replacement model Grundfos Wilo KSB Biral DAB Speck alm alm Product no. UPS - Star-RS / - M UPA -. U UPS - Star-RS / Rio C - M - VA / / - UPA -. U UPS -6 Star-RS /6 Rio C -6 M - VA / / - UPA -6. U VA / M N / UPA -. U UPS - C / Rio - VA / M N / UPA -. U VA / M - UPA -. U UPS -6 - C /6 Rio - VA / M - UPA -6. U VA / M - UPA -7. U UPS - Star-RS / - - VA / - UPA -. U UPS - UPS -6 Star-RS / Gold * Star-RS /6 Gold 6* UPS - Star-RS / Rio C - M UPA -. U - - VA / - UPA -6. U UPS - Star-RS / Rio C - VA /8 UPS - Star-RS / Rio C / M - - UPS -6 Star-RS /6 Rio C -6 M - VA /8 N / VA / N / VA / N / VA / N / VA /6 UPA -. U 8 UPA -. U 8 UPA -. U 8 UPA -6. U M - - VA /6 UPA -7. U 8 UPS - Star-RS / Rio C - M - - N / UPA -. U 8 UPS - Star-S / Rio C - - VA /8 X UPS - Star-RS /6 Rio C /6 M - - UPS -6 Star-RS /6 Rio C -6 M - VA /8 X N / VA / N / VA / N / VA /6 UPA -. U 8 UPA -. U 8 UPA -6. U 8 EP Plus -. E / -. EP Plus -. E / -. EP Plus -6. E / -. EP Plus -. E / -. EP Plus -. E / -. EP Plus -6. E / -6. EP Plus -6. E / -6. EP Plus -7. E / -7. EP Plus -. E / -. EP Plus -6. E / -6. EP Plus -6. E / -6. EP Plus -. E 8 / -. EP Plus -. E 8 / -. EP Plus -6. E 8 / -6. EP Plus -6. E 8 / -6. EP Plus -7. E 8 / -7. EP Plus -. E 8 / -. EP Plus -. E 8 / -. EP Plus -6. E 8 / -6. EP Plus -6. E 8 / -6. * UK only 6

27 Replacement lists Grundfos - Wilo - KSB - Biral - DAB - Speck - alm product group UPA-Solar series Grundfos Wilo KSB Biral DAB Speck alm Product no. UPS Solar - Star - ST / - SX UPA-Solar -. U - UPS Solar - 6 Star - ST /7 - SX UPA-Solar -7. U UPA-Solar -. U UPA-Solar -7. U -7 UPS Solar UPA-Solar -. U - UPS Solar UPA-Solar -7. U -7 UPS Solar - Star - ST / - SX UPA-Solar -. U 8 - UPS Solar - 6 Star - ST / UPA-Solar -7. U UPA-Solar -. U UPA-Solar -7. U 8-7 Replacement lists Grundfos - Wilo - KSB - Biral - Speck - Laing - alm B product group BUPA series Grundfos Wilo KSB Biral Speck Laing UP - B/N Z * Riotherm C - W * BN S- / 7 B - - R - E * W W W - - UP - / B / N Star-Z / * - W * - S- / B UPS - N Star-Z / C - W - - UP - N TOP-Z / C - W BA / - UP - N TOP-Z / - W BA / W BN / S- / B - - Riotherm C - W BN / W BVA / - UPS - B Star-Z / - W BVA / - UPS -6 B Star-Z /6 Riotherm C -6 W - - alm standard pump / Product no. BUPA -. U / - BUPA -. U / - BUPA -. U / - BUPA -6. U / -6 BUPA -. U / - BUPA -. U / - BUPA -. U / - BUPA -6. U / -6 BUPA -. U / - BUPA -. U / - BUPA -6. U / -6 BUPA -. U 8 / - BUPA -6. U 8 / -6 Replacement models alm high eff. pump / Product no. EP Plus (N) -. E / -. EP Plus (N) -. E / -. EP Plus (N) -. E / -. EP Plus (N) -6. E / -6. EP Plus (N) -. E / -. EP Plus (N) -. E / -. EP Plus (N) -. E / -. EP Plus (N) -6. E / EP Plus (N) -. E 8 / -. EP Plus (N) -6. E 8 / -6. * note differing installation lengths 7

28 Replacement lists Grundfos - Wilo - KSB - Biral - Speck - Laing - alm KG product group KGPA series Grundfos Wilo KSB Biral Speck Laing alm Product no. - TOP-S /7 Rio - 7 MX / M - VA /6 - KGPA -7. U 8-7 UPS MX / M KGPA -8. U 8-8 UPS -8 TOP-S /7 Rio - 7 MX / M - VA /7 - KGPA -7. U Rio KGPA -8. U TOP-S / Rio - MX / M - VA /86 - KGPA -. U Rio KGPA -. U 8-8

29 Notes 9

30 Notes

31

32 Your representative: Art. No. 8-6-EN-EU Version. (/) alm Pumpen + Motoren Gmb Silcherstrasse Baltmannsweiler Germany Postfach Baltmannsweiler Germany Phone: +9 ()7 9- Fax: +9 () info@halm.info

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULATORS TECNICAL DATA EVOTRON WET ROTOR ELECTRONIC CIRCULATORS Operating range: from, -, m/h with head of up to metres. Pumped liquid temperature range: from -1 C to +11 C. Working

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m B a l t i m o r e A i r c o i l C o m p a n y Baltimore Aircoil Company is recognized as the world s largest manufacturer of evaporative heat transfer and thermal storage equipment. BAC products are supplied

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Technical information Installation instructions

Technical information Installation instructions EN Technical information Installation instructions Calorifier ComiVal CR (00-000) ComiVal CSR (00-000) MultiVal CRR (00-000) MultiVal CSRR (0-000) Hoval products must e installed and commissioned only

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady ELECTRONIC CIRCULATORS OR EATING AND COOLING SYSTEMS ErP eady TECNICAL DATA EVOSTA 2 WET ROTOR ELECTRONIC CIRCULATORS Operating range:,-3,6 m 3 /h with head up to 6,9 metres. Pumped liquid temperature

More information

Precision Ball Screw/Spline

Precision Ball Screw/Spline 58-2E Models BNS-A, BNS, NS-A and NS Seal Outer ring Shim plate Seal Spline nut Seal Collar Shim plate Seal End cap Ball Outer ring Ball screw nut Outer ring Ball Retainer Retainer Outer ring Point of

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP SERIES - PERIPHERAL PUMPS Page No. General

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULTORS Technical Sheet ELECTRONIC CIRCULTORS FOR ETING ND IR CONDITIONING SYSTEMS Energ ia e y GENERL DT compliant with the 3 and european directive ErP 9//EC (ex EuP) pplications

More information

System Components. Electric Motors.

System Components. Electric Motors. System Components Electric Motors www.powerjacks.com Contents.1. Electric Motors.1.1. AC Motors.1.. AC Motor Performance 0 rpm ( pole).1.. AC Motor Performance 00 rpm ( pole).1.. AC Motors with Integral

More information

Multifunctional Thermostatic Circulation Valve MTCV

Multifunctional Thermostatic Circulation Valve MTCV Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version

More information

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled Benchtop, Underbench and Floorstanding Centrifuges classic/cooled PERFORMANCE Efficient, results-oriented working processes are top priority in both research and routine laboratories. Advanced laboratory

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

PRO-CLEAN STRATIFIED TANK

PRO-CLEAN STRATIFIED TANK PO-CLEAN STATIFIED TANK PODUCT DESCIPTION Pro-Clean stratified tank with spherical exchanger connection High-quality, multifunctional stratified tank made of steel (S J) for hot-water operation and domestic

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

DBS315 1-phase SIDE CHANNEL BLOWERS

DBS315 1-phase SIDE CHANNEL BLOWERS DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz

P U M P S. The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 50Hz P U M P S THE BENCHMARK FOR PERFORMANCE The quality standard for hydraulic efficiency and suction lift. PERIPHERAL PUMPS TEP/ TSP - SERIES 5Hz I N D E X TEP / TSP / TRP SERIES - PERIPHERAL PUMPS Page

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q

More information

1/54 Circulation pump, safety valve, expansion vessel

1/54 Circulation pump, safety valve, expansion vessel 1/54 Circulation pump, safety valve, expansion vessel pressure loss efficiency of pump secured heat output safety valve sizing expansion vessel sizing Circulation pump 2/54 similar principle as for heating

More information

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details) Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.

More information

Magnetic couplings, stirrer drives for Chemical Reactors bmd and cyclone: Absolutely tight, safe and dependable

Magnetic couplings, stirrer drives for Chemical Reactors bmd and cyclone: Absolutely tight, safe and dependable Magnetic couplings, stirrer drives for Chemical Reactors and cyclone: Absolutely tight, safe and dependable Büchi quality Easy maintenance Compact design Well designed Efficient stirring / mixing full

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

IL series. Centrifugal marine IN-LINE pumps

IL series. Centrifugal marine IN-LINE pumps IL series Centrifugal marine IN-LINE pumps DESCRIPTION Vertically built centrifugal IN-LINE pumps are made with standardized DIN-22 parts, with in-line suction and discharge flanges. This arrangement requires

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm Tangential Fans Series TW Impeller diameter mm and 0 mm 105 Corporate Drive, Suite E Spartanburg, SC 293 PO Box 2889, Spartanburg, SC 294 USA Tel: 864-599-63 Fax: 864-599-6344 e-mail: info@ltg-inc.net

More information

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H

TPH. 60Hz. Standard mode TPH 4T 2K. Code TPH 4T 2K S F A H C US NSF/ANSI TPH Applications: The TPH Series are modernly designed with quiet and high efficient operation pumps, suitable for dependable water transfer, circulating or booster service. -Industrial circulation

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 00 H Delivery flow Pressure p max max.

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

The electronic actuator for future-proof applications

The electronic actuator for future-proof applications Stellantriebe The electronic actuator for future-proof applications Safe Economical Precise www.arisactuators.com Intelligent Line The next generation actuator technology Innovative electronics versus

More information

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200 OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT NR FREELY PROGRAMMABLE ROTARY TABLES NR ROTARY RING TABLE All NR rings allow customer-specific drive motors to be connected NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT WHEN IT S GOT TO BE EXACT We

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S for Euro_ET (R4A, Hz, HP) Model : Premium (Compact / Energy Efficiency) Type Standard Type History Version Modification Date Remark Ver. 1. Release DVM S (R4A, Hz, HP) for

More information

Radial piston pump type R and RG

Radial piston pump type R and RG Radial piston pump type R and RG with radial piston pump acc. to D 6010 and several pressure outlet Operating pressure p max = 700 bar Delivery flow Q max = 76.0 lpm (at 1450 rpm) Radial piston pumps type

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

equator COMBINATION OVENS

equator COMBINATION OVENS equator COMBINATION OVENS EQUATOR the new generation of combination ovens Since 2007, with the ITW group at the head of 840 facilities in 57 countries Bonnet has benefitted from its research and development

More information

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

PHOS 15 LED PROJECTOR

PHOS 15 LED PROJECTOR PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....

More information