For. LED Package. : Sep. 17, Date of Test. LED Light Source. Review by: Engineer:

Size: px
Start display at page:

Download "For. LED Package. : Sep. 17, Date of Test. LED Light Source. Review by: Engineer:"

Transcription

1 IES LM Test Report For Hangzhou Hangke Optoelectronics Joint Stock Co., LTD Hangke Industrial Park, 33 Xianxing Road, Xianlin Industrial Zone, Hangzhou LED Package Model: TOP LED 2835 Laboratory: Leading Testing Laboratories NVLAP CODE: a Tel: Report : HZ a The laboratory that conducted the t testing detailed in this report has been accreditedd for SSL by NVLAP. Test specifications: Date of Receipt Date of Test Test item Referencee Standard : Sep. 17, 2012 : Sep. 18, 2012 to Jul. 10, 2013 : 6000 hours Lumen Maintenance, hours Chromaticity Shift : IES LM Approved Method for f Measuring Lumen Maintenance of LED Light Source Review by: Approved by: Engineer: April Zou July.12, 2013 Manager: Jim Zhang July.12, 2013 Note: This report does not imply product certification, approval, or endorsement byy NVLAP, NIST, or any agency of the Federal Government.

2 Test Summary Ts ( ) Average Lumen Maintenance (%) at 6000 hours Average Chromaticity Drive Current (A) Number of LED Light Sources Tested % % % IES LM Test Report Requirement: 1. Number of LED Light Sources Tested See test summary. ( u v ) at 6000 hours 2. Description of LED light sources Device under test is LED package with model number: TOP LED 2835, nominal CCT 3000K. 3. Description of auxiliary equipment Lifetest thermal chamber NMT 830 Lifetest current source Itech IT6720 Lifetest data recorder GRAPHTEC GL820 Photometric test current source Itech IT6154 Photometric test system 0.5m Integrate Sphere system 4. Operating cycle LEDs are driven with a constant direct current (DC). 5. Ambient conditions including airflow, temperature, and relative humidity Ambient Temperature (Ta): See Tables Humidity: <65% No force air flow 6. Case temperatures (test point temperature) In all cases, both Ts and Ta meet the IES LM limits. Ts Point Prepared by: Leading Testing Laboratories Co., Ltd Page 2 of 10

3 7. Drive current of the LED light source during Lumen maintenance test. See tables. 8. Initial luminous flux and forward voltage at photometric measurement current See tables. 9. Lumen maintenance for data for each individual light source along with median value, standard deviation, minimum and maximum lumen maintenance value for all of the light sources See tables. 10. Observation of LED light source failures including the failure conditions and time of failure No failures observed. 11. LED light source monitoring interval See tables 12. Photometric measurement uncertainty Flux measurement: 1.39% (k=2) 13. Chromaticity shift reported over the measurement time See tables. 14. Sampling Method/ size IES LM-80 tests require LED samples to be operated at a minimum of a single current and three temperatures of 55C, 85C and a third temperature picked by the LED manufacturer. 75 pieces of LED samples are selected randomly from different production date of products. These samples are picked to represent a wide parametric distribution. Prepared by: Leading Testing Laboratories Co., Ltd Page 3 of 10

4 Test Result: Case temperature: 55 Lumen Maintenance Data: 0h Lumen Maintenace (%) Vf(V) Flux (lm) 1000h 2000h 3000h 4000h 5000h 6000h % % % % % % % % % 98.41% 98.13% 97.03% % % % 99.00% 98.76% 97.67% % % % 99.58% 99.29% 98.18% % % % % 99.96% 98.87% % % % 99.53% 99.26% 98.07% % % % % % 99.89% % % % % % 98.84% % % % % % 99.06% % % % % % 98.84% % % % % % 99.26% % % % 99.14% 98.96% 97.79% % % % % % 99.82% % % % % % 99.31% % % % % % 99.53% % % % 99.83% 99.63% 98.45% % % % 99.27% 99.04% 97.86% % 99.60% 97.96% 98.92% 98.74% 97.65% % % % 99.20% 99.02% 97.84% % % % % % 99.72% % % % % % % % % % % 99.84% 98.68% % % % % 99.92% 98.73% % % % % % 99.03% % % 98.78% 98.79% 98.55% 97.42% Avg % % % % 99.85% 98.71% Max % % % % % % Min % 99.60% 97.96% 98.41% 98.13% 97.03% Lumen Maintenance 55 Lumen maitenance % % % 95.00% 90.00% 85.00% 80.00% 75.00% 70.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 4 of 10

5 Case temperature: 55 Chromaticity Shift Data: 0h Chromaticity Shift u v CCT K 1000h 2000h 3000h 4000h 5000h 6000h Avg Max Min Chromaticity Shift at 55 u'v' 2.50% 2.00% 1.50% 1.00% 0.50% 0.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 5 of 10

6 Case temperature: 70 Lumen Maintenance Data: 0h Lumen Maintenace (%) Vf(V) Flux (lm) 1000h 2000h 3000h 4000h 5000h 6000h % 99.76% 99.57% 98.04% 97.76% 96.90% % % 97.92% 98.07% 97.78% 96.84% % 98.01% 97.22% 96.89% 96.53% 95.67% % % 98.61% 97.33% 97.01% 96.09% % % 97.61% 97.84% 97.49% 96.53% % % 98.67% 98.06% 97.72% 96.83% % % 98.20% 96.36% 96.14% 95.24% % 98.89% 96.11% 98.08% 97.92% 97.06% % % 98.13% 97.95% 97.58% 96.66% % % 97.68% 97.00% 96.71% 95.77% % % 97.23% 96.97% 96.82% 95.86% % % 97.49% 96.73% 96.39% 95.50% % % 98.04% 97.73% 97.58% 96.65% % % 98.37% 96.71% 96.41% 95.50% % % 97.53% 96.80% 96.58% 95.73% % % 98.42% 97.35% 97.05% 96.11% % 99.65% 96.92% 96.78% 96.40% 95.54% % % 96.95% 96.43% 96.06% 95.15% % % 97.16% 96.79% 96.43% 95.50% % % 97.50% 96.95% 96.67% 95.74% % % 97.82% 96.50% 96.33% 95.46% % % 98.16% 97.62% 97.24% 96.40% % % 97.95% 98.90% 98.56% 97.68% % 98.08% 97.14% 96.69% 96.31% 95.35% % 99.48% 97.46% 98.01% 97.69% 96.83% Avg % % 97.75% 97.30% 97.01% 96.10% Max % % 99.57% 98.90% 98.56% 97.68% Min % 98.01% 96.11% 96.36% 96.06% 95.15% Lumen Maintenance 70 Lumen maitenance % % % 95.00% 90.00% 85.00% 80.00% 75.00% 70.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 6 of 10

7 Case temperature: 70 Chromaticity Shift Data: 0h Chromaticity Shift u v CCT K 1000h 2000h 3000h 4000h 5000h 6000h Avg Max Min Chromaticity Shift at 70 u'v' 2.50% 2.00% 1.50% 1.00% 0.50% 0.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 7 of 10

8 Case temperature: 85 Lumen Maintenance Data: 0h Lumen Maintenace (%) Vf(V) Flux (lm) 1000h 2000h 3000h 4000h 5000h 6000h % 96.92% 95.56% 94.15% 93.91% 93.13% % 99.15% 96.11% 91.47% 90.80% 89.97% % % 98.18% 93.96% 93.32% 92.51% % 99.26% 96.01% 92.87% 92.10% 91.29% % % 96.53% 92.18% 91.50% 90.71% % % 97.73% 93.41% 93.25% 92.39% % % 97.45% 92.72% 92.42% 91.54% % 99.18% 95.15% 92.76% 92.31% 91.44% % % 97.86% 92.75% 92.37% 91.49% % 99.98% 97.68% 93.76% 93.04% 92.18% % 98.70% 94.94% 92.29% 92.10% 91.28% % 99.65% 95.92% 94.42% 93.71% 92.90% % % 99.75% 94.17% 93.75% 92.98% % % 98.24% 93.65% 93.04% 92.22% % 98.99% 98.46% 94.10% 93.53% 92.69% % % 97.04% 94.13% 93.52% 92.69% % % 98.04% 92.22% 92.03% 91.18% % 99.75% 96.25% 91.19% 90.67% 89.88% % % 98.11% 91.11% 90.79% 89.92% % % 95.58% 93.96% 93.55% 92.70% % % 97.04% 94.00% 93.65% 92.86% % 99.89% 95.99% 91.17% 90.61% 89.72% % 99.07% 96.57% 91.88% 91.36% 90.52% % 97.08% 95.66% 91.02% 90.50% 89.73% % % 98.14% 94.81% 94.09% 93.19% Avg % 99.91% 96.96% 92.97% 92.48% 91.64% Max % % 99.75% 94.81% 94.09% 93.19% Min % 96.92% 94.94% 91.02% 90.50% 89.72% Lumen Maintenance 85 Lumen maitenance % % % 95.00% 90.00% 85.00% 80.00% 75.00% 70.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 8 of 10

9 Case temperature: 85 Chromaticity Shift Data: 0h Chromaticity Shift u v CCT K 1000h 2000h 3000h 4000h 5000h 6000h Avg Max Min Chromaticity Shift at 85 u'v' 2.50% 2.00% 1.50% 1.00% 0.50% 0.00% Prepared by: Leading Testing Laboratories Co., Ltd Page 9 of 10

10 HZ a TM-21 Report: Table 1: Report at each LM-80 Test Condition Description of LED Light Source Tested (manufacturer, model) Hangzhou Hangke Optoelectronics Joint Stock Co., LTD Test Condition 1-55⁰C Case Temp Test Condition 2-70⁰C Case Temp Test Condition 3-85⁰C Case Temp size 25 size 25 size 25 Number of failures 0 Number of failures 0 Number of failures 0 DUT drive current used in the test (ma) 60 DUT drive current used in the test (ma) 60 DUT drive current used in the test (ma) 60 Test duration (hours) 6,000 Test duration (hours) 6,000 Test duration (hours) 6,000 Test duration used for projection (hour to hour) 1,000-6,000 Test duration used for projection (hour to hour) 1,000-6,000 Test duration used for projection (hour to hour) 1,000-6,000 Tested case temperature (⁰C) 55 Tested case temperature (⁰C) 70 Tested case temperature (⁰C) 85 α 3.260E-06 α 6.390E-06 α 1.936E-05 B B B Calculated L70(6k) (hours) 113,000 Calculated L70(6k) (hours) 56,000 Calculated L70(6k) (hours) Reported L70(6k) (hours) >36000 Reported L70(6k) (hours) >36000 Reported L70(6k) (hours) 20,000 20,000 End of the Report Prepared by: Leading Testing Laboratories Co., Ltd Page 10 of 10

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9 LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0

More information

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W LM-79-08 Test Report For MaxLite Inc. 12 York Ave West Caldwell NJ 07006, USA LED Commercial Down lights Model: RR82540W Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542991XX(XX:41-50) Laboratory: Leading Testing

More information

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50) LM-79-08 Test Report For Elec-Tech International Co., Ltd NO.1 JINFENG ROAD,TANGJIAWAN TOWN,XIANGZHOU DISTRICT,ZHUHAI CITY,GUANGDONG PROVINCE T8 LED TUBE Model: 542961XX(XX:41-50) Laboratory: Leading Testing

More information

OSLON SQUARE White (CCT 2400K 5000K)

OSLON SQUARE White (CCT 2400K 5000K) OSLON SQUARE White (CCT 2400K 5000K) IES LM-80-08 Lumen and Chromaticity Maintenance Test Report Successor of OSLON SSL (Test Doc. 100329W9) IES TM-21-11 Long Term Projection of Lumen Maintenance Test

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:

More information

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB15W27-50K-D-T5-A-P

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P

More information

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For IES LM-79-08 MEASUREMENT AND TEST REPORT For MESTER LED LIMITED 3rd F, Building A,Sunshine Industrial Park, Hezhou, Xixiang, Bao an District,Shenzhen China Test Model: PL09G2427KBQH Report Type: Electrical

More information

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1 LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K

More information

LED Lumen Maintenance and Life Test System (LEDLM-80PL) Brochure. Global Office of Lisun Electronics Inc.

LED Lumen Maintenance and Life Test System (LEDLM-80PL) Brochure. Global Office of Lisun Electronics Inc. LED Lumen Maintenance and Life Test System (LEDLM-80PL) Brochure Global Office of Lisun Electronics Inc. Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road,

More information

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/827K-DIM-G6 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063 Report No.: EED35I000235-1 Page 1 of 12 Customer : Revolution Lighting Technologies Address : 4139 Guardian Street, Simi Valley, CA93063 Description of the submitted sample(s): Sample Name : LED TUBE Model/Type

More information

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For IES LM-79-08 MEASUREMENT AND TEST REPORT For Shenzhen Jiawei Photovoltaic Lighting Co., Ltd. No. 1,2,3,4, Xinfa Industry Zone, Central Community, Pingdi Road, Longgang District, Shenzhen City, Guangdong

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N

More information

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL IES LM-79-08 MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Test Model: IGTFL-1515050 Report Type: Test Engineer: Electrical and Photometric tests including:

More information

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM IES LM-79-08 MEASUREMENT AND TEST REPORT For Eiko Limited 23220 W. 84th Street,Shawnee, KS, USA Test Model: LEDP-13WPAR30/NFL/830-DIM Report Type: Test Engineer: Electrical and Photometric tests including:

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W

More information

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN NVLAP LAB CODE 201071-0 LM-79-08 Test Report for Forest Lighting Corporate Address: 2252 Northwest Parkway SE, Suite D, Marietta, GA 30067 LED Tube Model: FL-T8U450-15-BN Laboratory: Leading Testing Laboratories

More information

Test Report. Report Number: L14139 Date: Jul 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14139 Date: Jul 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14139 Date: Jul 21, 2015 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay Fixture Unit manufacturer: Dialight Corporation Unit model number:

More information

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es) LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11

More information

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire TESTING Report No.:BL160912008-9A NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Applicant: Maxlite.Inc Address:

More information

IES LM TEST REPORT For EIKO GLOBAL, LLC

IES LM TEST REPORT For EIKO GLOBAL, LLC NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For EIKO GLOBAL, LLC Report Number: Product Type: Date of Receipt: Date of Test: Date of Report: Product

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IESLM-79-08TESTREPORT For KINGLUMI CO., LTD Report Number: Product Type: R011601998L1 Track or Mono-point Directional Luminaires Date

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272, sdelaurentis@keystoneballast.com

More information

Test report of IES LM Approved Method: Electrical and Photometric

Test report of IES LM Approved Method: Electrical and Photometric NVLAP LAB CODE 600102-0 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Date of issue 2016-05-17 Version 1.0 Total pages 16 Applicant:

More information

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK) LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor

More information

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For IES LM-79-08 MEASUREMENT AND TEST REPORT For Suzhou RUNLUX Electric Ltd. Kunshan Economic&Technological Development Zone, Kunshan City, Jiangsu, P.R.China. Test Model: R1-22TLD30W35K Report Type: Test

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: ) LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC

More information

OPTO Laboratory Test Report IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE. Test Date January 16, 2014 to April 8, 2015.

OPTO Laboratory Test Report IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE. Test Date January 16, 2014 to April 8, 2015. IES LM-80-08 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE Report Number Test Sample Q131107 2T03X5WW11000003 Rating DC 150mA 0.5W Normal CCT 2,700 K Test Date January 16, 2014 to April 8, 2015 Test

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Keystone Technologies 1390 Welsh Road,North Wales, PA 19454 Stephanie DeLaurentis, 267-656-2272,

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For DONGBU LIGHTEC CO. LTD 14, Saneop-ro 104beon-gil, Ojeong-gu, Bucheon-si, Gyeongg-do, Korea

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,

More information

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For Shenzhen sunper opto co., ltd NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For Shenzhen sunper opto co., ltd Report Number: Product Type: R011506618L Architectural Flood and Spot Luminaires

More information

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd. NVLAP LAB CODE:201045-0 TEST REPORT IES LM-79-08 For Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Report

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite Inc 10 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x146,

More information

Cat# LED Linear High Bay 100W

Cat# LED Linear High Bay 100W Cat# 71724 LED Linear High Bay 100W QPL ID # PRNKSMPK OVERALL LAMP PARAMETERS LED DRIVER LIFESPAN & ENVIRONMENT OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71604 UPC Number 60198671604 Description LED Ultra Thin Canopy Fixture 45W Voltage: 120/208/240/277 QPL ID # P89A8PQ3 Features Intergral Cooling Fin Releases the Heat Efficiently to Maintain

More information

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Report No.: HZ p. (Lumens) Stabilization Time CRI (K) Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)

More information

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight Page 2 of 14 Report No.: 68.184.15.296.01 Test sample... : Type of test object... : LED Downlight LED Downlight Trade mark... : Model and/or type reference... : EF150-26W-840 Rating(s)... : 220-240V~;

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D

More information

TEST REPORT For Company:

TEST REPORT For Company: TEST REPORT For Company: EiKO Global, LLC 23220 W. 84th Street, Shawnee, KS 66227 Model: LED17WBR40/840K-DIM-G4 Report Type: Test Engineer: Testing and Report According to ENERGY STAR Program Requirements

More information

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS

Wet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS 71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp. 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-150W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50 IES LM-79-08 MEASUREMENT AND TEST REPORT For ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA 91730 Test Model: HBUF-100W-50 Report Type: Test Engineer: Electrical and Photometric tests

More information

LED Entryway Light RoHS

LED Entryway Light RoHS 72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08473-001A SA21-16027MDFD-12DE26-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Test Report. Report Number: L15097 Date: Jul 29, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15097 Date: Jul 29, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1597 Date: Jul 9, 15 Issued by: 151 Route 34 South, Farmingdale, NJ 777 Test of one 14k C1D Vigilant High Bay Unit manufacturer: Dialight Corporation Unit model number: HEDGMC4GN-xxx

More information

Test Report. Report Number: L14064 Date: Sep 30, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14064 Date: Sep 30, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14064 Date: Sep 30, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay Fixture With Clear Acrylic Lens Unit manufacturer: Dialight Corporation

More information

TEST REPORT. Test Method : See the attached sheets.

TEST REPORT. Test Method : See the attached sheets. Applicant: Radomir Klabal Komenskeho 446, Bilovice nad Svitavou, Czech Republic Sample Description Product : Compact Fluorescent Lamp Model No. : CFL20T2S27E27 Brand Name : Divetta Electrical Rating :

More information

Test Report. Report Number: L14062 Date: Sep 22, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14062 Date: Sep 22, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14062 Date: Sep 22, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay fixture Unit manufacturer: Dialight Corporation Unit model number:

More information

Test Report. Report Number: L15098 Date: Jul 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15098 Date: Jul 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L158 Date: Jul 28, 215 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 18k C1D2 Vigilant High Bay Unit manufacturer: Dialight Corporation Unit model number: HEDGMC4KN-xxx

More information

TEST REPORT. Page 1 of 11

TEST REPORT. Page 1 of 11 Applicant: Radomir Klabal Komenskeho 446, Bilovice nad Svitavou, Czech Republic Sample Description Product : Compact Fluorescent Lamp Model No. : CFL15T2S27E27 Brand Name : Divetta Electrical Rating :

More information

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1679 Date: Oct 12, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 2' Gen II Linear Unit manufacturer: Dialight Corporation Unit model number: LTx3B4B2W

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08391-001A S-DL8-A-34L-27K-M w_s-dl8t-a-ss-c Date: 05/26/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08381-001A S-DL4-A-42L-35K-M w_s-dl4t-a-ss-c Date: 05/24/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08388-001A S-DL6-A-42L-27K-M w_s-dl6t-a-ss-c Date: 05/19/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Test Report. Report Number: L16056 Date: Jun 14, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16056 Date: Jun 14, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1656 Date: Jun 14, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 2 Test of one Vigilant H6 Series Unit manufacturer: Dialight Corporation Unit model number: H6xGMC9WN-xxxx

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08392-001B S-DL8-A-42L-27K-M w_s-dl8t-a-ss-c Date: 06/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy

More information

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham

More information

LM-79 Report TEST REPORT NO. L523A

LM-79 Report TEST REPORT NO. L523A LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL843-1A S-CT-MFB-5L-36D-3K-xx Date: 5/26/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08073-001A S-DL6-63L-27K w_s-dl6t-w-ss-c Date: 05/09/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Test Report. Report Number: L14121 Date: Nov 20, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14121 Date: Nov 20, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14121 Date: Nov 20, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay With Clear Polycarbonate Lens Unit manufacturer: Dialight Corporation

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08367-001A SB13-02427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08368-001A SB13-03427MDCH-12GE12-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Test Report. Report Number: L16019 Date: Mar 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16019 Date: Mar 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1619 Date: Mar 21, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 2 Test of one CID1 Battery Backup Linear Unit manufacturer: Dialight Corporation Unit model number: LSC3C4MEGEX

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount.   EPA Rating 2. Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output

More information

Test Report. Report Number: L14127 Date: Dec 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14127 Date: Dec 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14127 Date: Dec 9, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay Fixture With Glass Lens Unit manufacturer: Dialight Corporation Unit

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL09245-001A SPAR38-1503025TD-12DE26-1 Date: 9/14/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL08049-001A S-DL6-15L-27K w_s-dl6t-w-ss-c Date: 04/13/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 577- Report Number: Model: PL87-1A S-DL8-5L-27K w_s-dl8t-w-ss-c Date: 5/9/216 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:

More information

Test Report. Report Number: L15021 Date: Mar 16, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15021 Date: Mar 16, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L15021 Date: Mar 16, 2015 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay With Clear Acrylic Lens fixture Unit manufacturer: Dialight Corporation

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08254-001A S-DL4-A-42L-40K-W w_s-dl4t-a-ssc Date: 04/27/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08050-001A S-DL4-15L-40K w_s-dl4t-m-ss-c Date: 05/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information