Vision Experiment on White Light Chromaticity for Lighting Duv levels Perceived Most Natural
|
|
- Fay Burns
- 6 years ago
- Views:
Transcription
1 CIE/USA-CNC/CIE Biennial Joint Meeting, Davis, CA, Nov. 7-8, 2013 Vision Experiment on White Light Chromaticity for Lighting Duv levels Perceived Most Natural Yoshi Ohno *1 and Mira Fein *2 1 National Institute of Standards and Technology, Gaithersburg, Maryland, USA Ph. D., NIST Fellow, IESNA Fellow, CIE VP Technical 2 Psychology Department, Oberlin College, Oberlin, Ohio, USA NIST Guest Researcher under NIST Summer Undergraduate Research Fellowship Program 1
2 Traditional White Light Chromaticities for Lighting ANSI C for fluorescent lamps IEC for Fluorescent Lamps CIE 1931 (x, y) Diagram 2
3 ANSI C (for Solid State Lighting Products) 3
4 Chromaticity shift across Planckian Locus Anecdotes say Lights below Planckian locus look better. An example in neodymium lamp A*STAR NMC Seminar 4
5 Recent Study on white light perception by LRC 20 observers Viewed the white box immediately after light was shown. Viewed after 45 sec. (adaptation for each light) No adaptation (only 4 sec. closing eyes) before immediate viewing of next light. (subject was adapted to previous light?) M. S. Rea,* J. P. Freyssinier, White Lighting, Volume 38, Number 2, April 2013 A*STAR NMC Seminar 5
6 Duv defined in ANSI C Closest Symbol: distance D from the Planckian locus on the (u', 2/3 v') diagram, with + uv sign for above and - sign for below the Planckian locus. Duv scale on (u, v ) diagram + Duv -Duv A*STAR NMC Seminar 6
7 NIST Spectrally Tunable Lighting Facility A*STAR NMC Seminar 7
8 NIST Spectrally Tunable Lighting Facility A*STAR NMC Seminar 8
9 9
10 Uncertainty of measurement of Duv : ~ (k=2) 10
11 Experimental Design 4500 K 3500 K 2700 K Experiments prepared for 4 CCTs, at 6 Duv points at each CCT, at total 23 points K Spectra prepared for the 23 points plus points in between and outside, total 50 points. 11
12 Light spectra Qa=97 Qa=96 Qa=96 Qa=95 12
13 Experimental Design 18 subjects (all having normal color vision) 11 7 Ages ranging from years old 70 years old 13
14 Experimental Setting Room was set with neutral light gray walls (for main experiment) Illuminance ~300 lx on the table (variations within ±1 %). Subjects viewed fruits on the table, his/her face skin tone in mirror and the whole room. 14
15 Fresh fruits and vegetables on the table (replaced every one to three days) Apple (red) Apple (pale red) Orange Banana Tomato Orange Green pepper lettuce Strawberry grapes 15
16 Preparation for each subject Ishihara Test for normal color vision Explanations on experiment Instructions (questions, use of mouse) Trial run 16
17 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition 17
18 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Is this light acceptable or not? 18
19 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 19
20 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 20
21 Which light looks more natural? 21
22 Which light looks more natural? 22
23 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 23
24 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair Is this of lights light switched every acceptable 3 seconds or not? Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 24
25 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 25
26 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 26
27 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 27
28 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair of lights switched every 3 seconds Question: Which light looks more natural? Subject clicked the mouse when more natural light is presented. 28
29 Experimental Procedures 3500 K 6 Duv points at each run for one CCT 2 directions for each CCT 4 CCTs 2 repeated runs for each condition Pair Total of 16 lights runs, switched 92 every comparisons 3 seconds of pairs of light per subject. Question: Which light looks Took more ~ 4 h per natural? subject. Subjects clicked chose the one half mouse day session when or more two 2 h natural sessions light on different is presented. dates. 29
30 In addition, six subjects repeated experiments with brownish walls identically furnished. 30
31 Raw Data (for each subject) K backward K forward K backward K forward Average higher Duv chosen 1 lower Duv chosen 31
32 Plotting data (for each subject) K backward K forward K backward K forward Average K forward K backward K forward K backward Average K backward K forward K backward K forward Average K forward K backward K forward K backward Average Ratio of Negative Duv Chosen K Duv 50 % crossover point 32
33 Data Example (one subject) Ratio of Negative Duv Chosen K Duv Ratio of Negative Duv Chosen K Duv Ratio of Negative Duv Chosen K Duv Ratio of Negative Duv Chosen K Duv 33
34 50 % crossover points of Duv (one subject) Duv CCT (K) 34
35 50 % crossover points of Duv (all subjects) Duv Std.dev. 6500K 4500K 3500K 2700K CCT AVERAGE
36 Plotted on ANSI C
37 Results of Is this light acceptable or not? 37
38 Color rendering characteristics 38
39 Conclusions The chromaticity region below the Planckian Locus (Duv around 0.015) seems to be well preferred over white light on the Planckian locus for typical indoor applications. Results are similar at all CCTs (2700 K to 6500 K) different from the LRC results. Higher unacceptable rating at positive Duv at lower CCTs. Effects of brown wall was insignificant. Further experiments or observations with real application scenes are desired. We thank DOE for their support of this research. Thanks are also due to Dr. Podobedov at NIST who developed the control program for the experiment. THANK YOU FOR YOUR ATTENTION. Contact: ohno@nist.gov 39
NIST Role in Supporting Solid State Lighting Initiative
CORM 2007 Annual Meeting, Gaithersburg, May 8-11, 2007 NIST Role in Supporting Solid State Lighting Initiative Yoshi Ohno, Ph.D. Optical Technology Division National Institute of Standards and Technology
More informationReport of Test LLIA A
Report of Test LLIA000795-001A Catalog Number: GTSOL112-G2-HO-BR-NL Two Mean Well HLG-240H-C2100B LED drivers 120.0Vac, 60.00Hz, 2.811A, 335.1W, 0.994PF, 5.5%THD(i) Total Light Output Luminaire Power Luminous
More informationReport of Test LLIA A
Report of Test LLIA000998-002A Catalog Number: ML5WL-D-HO-ASY-K40-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 720mA. Total Light Output Luminaire Power Luminous Efficacy
More informationReport of Test LLIA A
Report of Test LLIA000998-001A Catalog Number: ML3WL-D-HO-ASY-K35-4-X-VR-X One Osram Optotronic OTi 50/120-277/1A 4 DIM L LED driver labeled as 600mA. Total Light Output Luminaire Power Luminous Efficacy
More informationIntroduction to Colorimetry
IES NY Issues in Color Seminar February 26, 2011 Introduction to Colorimetry Jean Paul Freyssinier Lighting Research Center, Rensselaer Polytechnic Institute Troy, New York, U.S.A. sponsored by www.lrc.rpi.edu/programs/solidstate/assist
More informationLightLab I N T E R N A T I O N A L
Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page
More informationLightLab I N T E R N A T I O N A L
Report of Test LLI-14188-20D Performance Summary Total Light Output 310 lm Min Power Factor 0.46 @ 277 V Luminaire Power 9.79 W Max THD(i)* 30.4 % @ 277 V Luminous Efficacy 31.7 lm/w SC along*, across*
More informationUncertainty determination of correlated color temperature for high intensity discharge lamps.
Uncertainty determination of correlated color temperature for high intensity discharge lamps A.B. El-Bialy 1, M.M. El-Ganainy 2 and E.M. El-Moghazy 3 1 University College for Woman for Art, science and
More informationUncertainty determination of correlated color temperature for high intensity discharge lamps
Uncertainty determination of correlated color temperature for high intensity discharge lamps A.B. El-Bialy 1, M.M. El-Ganainy 2 and E.M. El-Moghazy 3 1 University College for Woman for Art, science and
More informationNVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.
LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-1500LM-4000K Representative (Tested) Model: RPT-LEDBIAX-1500LM-4000K
More informationIES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager
IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous
More informationIES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager
IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/827K-DIM-G6 Report Type: Test Engineer: Electrical and Photometric tests including:
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )
LM-79-08 Test Report For Shenzhen Guanke Technologies Co. Ltd (Brand Name: ) 12th/13th floor of 3th building, Tongfuyu industrial area, heshuikou community, Gongming town 518106 Shenzhen, China. Replacement
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B/N FLS20U45B/N FLS20U50B/N FLS20U40W/N FLS20U45W/N
More informationPractical Optical Measurements of OLED Panels for Lighting Applications
Practical Optical Measurements of OLED Panels for Lighting Applications TOKI KAWABATA KONICA MINOLTA, INC. JAPAN YOSHI OHNO National Institute of Standards and Technology U.S.A. * This work was conducted
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS20U40B FLS20U45B FLS20U50B FLS20U40W FLS20U45W FLS20U50W
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006 Architectural Flood and Spot Luminaires Model name(s): FLS40U40B FLS40U45B FLS40U50B FLS40U40W FLS40U45W FLS40U50W
More informationNVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)
LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F, Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x2 Luminaires for Ambient Lighting of Interior
More informationLM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084
LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 ZOHO Series LED Flood Light Model name(s): BLTFLD50W5K Representative (Tested)
More informationNVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)
LM-79-08 Test Report For LED Wav es,inc (Brand Name: LED Wav es) 4100 1st Ave,The Esquire Building,Brooklyn, NY 11232 2x2 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): SL2-2X2-40W-11
More informationNVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503
Report No.: GZE150726-B LM-79-08 Test Report For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503 Four-Foot Linear Replacement Lamps Model name(s): IGTTU-1501850F-4BC
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-6 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT5Z02-9 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationTC KLV-T8-120 Led Tube by KLV LED Verlichting
TC KLV-T8-120 Led Tube by KLV LED Verlichting Page 1 of 18 Summary measurement data parameter meas. result remark Color 6330 K cold white temperature Luminous 440 Cd Measured straight underneath the lamp
More informationImprovement Uncertainty of Total luminous Flux Measurements by Determining Some Correction Factors
ISSN: 2347-325 Volume 3 Number 6 (June-205) pp. 264-274 www.ijcrar.com Improvement Uncertainty of Total luminous Flux Measurements by Determining Some Correction Factors Manal A. Haridy* Photometry and
More informationNVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada
LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada Four-Foot Linear Replacement Lamps Model name(s): IR-T8-15W4FT16503500K IR-T8-15W4FT16504000K IR-T8-15W4FT16505000K
More informationLM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN
NVLAP LAB CODE 201071-0 LM-79-08 Test Report for Forest Lighting Corporate Address: 2252 Northwest Parkway SE, Suite D, Marietta, GA 30067 LED Tube Model: FL-T8U450-15-BN Laboratory: Leading Testing Laboratories
More informationIES LM MEASUREMENT AND TEST REPORT For
IES LM-79-08 MEASUREMENT AND TEST REPORT For MESTER LED LIMITED 3rd F, Building A,Sunshine Industrial Park, Hezhou, Xixiang, Bao an District,Shenzhen China Test Model: PL09G2427KBQH Report Type: Electrical
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):
More informationLM-79 Report TEST REPORT NO. L523A
LM-79 Report TEST REPORT NO. L523A Test Result Summary Luminaire Manufacturer Pioneer Engineering Inc. Luminaire Model Number S ST-0246-5L-5K-120 Input Voltage RMS (V) 120.03 Input Current RMS (A) 0.28
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04395-001 BXSPRBxx3MEA30K-xxxxxx or XSPRBxx3MEA30K-xxxxxx Date: 9/09/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationNVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)
LM-79-08 Test Report For AOK LED LIGHT COMPANY LIMITED (Brand Name: AOK) Building 1, St George's Science and Technology Industrial Park, Shajin Street, Shenzhen, Guangdong Province, China Zip 518104 Outdoor
More information2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe
Lamp measurement report 16 July 2010 2x led tubes 150 cm in build-in luminaire ARM2x1500-A-INB-G4-NW by Led Light Europe Page 1 of 20 Summary measurement data parameter meas. result remark Color 5580 K
More informationIES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL
IES LM-79-08 MEASUREMENT AND TEST REPORT For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Test Model: IGTFL-1515050 Report Type: Test Engineer: Electrical and Photometric tests including:
More informationIES LM MEASUREMENT AND TEST REPORT. For
IES LM-79-08 MEASUREMENT AND TEST REPORT For Shenzhen Jiawei Photovoltaic Lighting Co., Ltd. No. 1,2,3,4, Xinfa Industry Zone, Central Community, Pingdi Road, Longgang District, Shenzhen City, Guangdong
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.02.05 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 12 foot mounting height..01.005.002 REPORT NUMBER: RAB02670 ISSUE DATE: 11/08/16 PAGE: 1 OF 9 DATE SAMPLE TESTED: 11/08/16 CATALOG
More informationLED Entryway Light RoHS
72508 LED Entryway Light RoHS QPL ID # PSMN8JUU Model: 72508 Input Voltage 120-277 VAC 60HZ Input Current 0.5A Max @120V Input Power 25W Power Factor PF 0.95 OVERALL LAMP PARAMETERS Luminance 3,121 LM
More informationIES LM MEASUREMENT AND TEST REPORT. For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB15W27-50K-D-T5-A-P
More informationIES LM MEASUREMENT AND TEST REPORT. For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P
More informationIES LM MEASUREMENT AND TEST REPORT. For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P
More informationIES LM MEASUREMENT AND TEST REPORT. For
IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P
More informationLM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A
LM-79-08 Test Report for MLS CO., LTD NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN City, GUANGDONG Linear Ambient Luminaires Model: MT8N20-A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: CESTL-2013-0154 BXSPRA*2FG-U** Date: 6/19/2013 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Tim Henning Cree, Inc 4600
More informationLM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl350u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Feb.20,2017 Review By: Manager: Tommy Liang Note:
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.2.5 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 10 foot mounting height. REPORT NUMBER: RAB00701 ISSUE DATE: 02/04/15 PAGE: 1 OF 8 CATALOG NUMBER: VXLED26NDG / VXBRLED26NDG LUMINAIRE:
More informationNVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl5s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Dec.05,2016 Review By: Manager: Tommy Liang Note:
More informationRoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.
Cat# 71893 380W LED FlatPanel Slipfitter Mount OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output
More informationWet Locations Use 71400A 120 W PF V 2.9A 93% 144 pcs. Philips 130 LM/W 5000K Hrs. 5 Years. 24-1/4 Lbs 665*530*120 1 PCS
71400A GAS STATION Canopy Luminaire Wet Locations Use QPL ID # PL9D2UU8ZA41 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power
More informationNVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1
LM-79-08 Test Report For Simkar Corporation (Brand Name: ) LED Luminaire Model name(s):salho2xl4s50u1 Test & Report By: Garman Mo Engineer: Garman Mo Date: Mar. 01,2017 Review By: Manager: Tommy Liang
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL05401-001 RULHT2MEC40K-12xxx Date: 02/11/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0031 BXSPWA02MC-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: Date: RESTL-2014-0032 BXSPWA03MG-US 01/28/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL03402-001 BXOSQAxx4MES40K Date: 04/15/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Brandon Bitner Cree,
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2.005.01.02 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 16 foot mounting height..002 REPORT NUMBER: RAB01042 ISSUE DATE: 07/15/15 PAGE: 1 OF 8 DATE SAMPLE TESTED: 07/15/15 CATALOG NUMBER:
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL07611-001A BXSPR-HO-HT-3ME-60W-57K-UL Date: 04/08/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher
More informationNVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)
LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-22W-ID(X,Clear)
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09259-001A OSQ-HO-A-xx-15D-40L-40K-UL Date: 09/26/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Chris Strom Cree,
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL07609-001B BXSPR-HO-HT-3ME-60W-30K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher
More informationMeasurement method for the proficiency testing program
APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 15 foot mounting height. REPORT NUMBER: RAB01308 ISSUE DATE: 10/21/15 PAGE: 1 OF 9 DATE SAMPLE TESTED: 10/21/15 CATALOG NUMBER: HAZXLED42FDG
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL07860-001B BXSPR-HO-xx-5SH-60W-40K-UL Date: 03/28/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Christopher
More informationNVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)
LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING) Rm 1902, Easey Comm Bldg,253-261 Hennessy Rd Wanchai, HONG KONG Four-Foot Linear Replacement Lamps Model name(s): HC-T8-4FT-13W-ID(X,
More informationA*STAR Seminar on LED and Solid State Lighting. Standards and Technologies. Measurements. 05 August LIU Yuanjie National Metrology Centre
A*STAR Seminar on LED and Solid State Lighting Standards and Technologies available at NMC for LED Measurements 05 August 2011 LIU Yuanjie National Metrology Centre Outline NMC overview Basic optical quantities
More informationLM-79 Report TEST REPORT NO.M037D
LM-79 Report TEST REPORT NO.M037D Test Result Summary Luminaire Manufacturer Luminaire Model Number Input Voltage RMS (V) 120.0 Input Current RMS (A) 0.231 Input Power (W) 27.47 Light Output (lm) 3524
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09255-002A OSQ-HO-A-xx-3ME-40L-40K-UL w/osq-ho-blsf Date: 09/09/16 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan
More informationLM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W
LM-79-08 Test Report For MaxLite Inc. 12 York Ave West Caldwell NJ 07006, USA LED Commercial Down lights Model: RR82540W Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More informationLesson 1: Living things:
C.W Lesson 1: Living things: - Living things: 1-2- 3- - Circle the living things: H.w: workbook page: ( ) 1 H.W - Write these words: Living things People Plant Animal 2 C.W Lesson 2: Properties of living
More informationSD-POWER LED Series. Technical Datasheet for SD-03/04
SD-POWER LED Series Technical Datasheet for SD-03/04 Features -Power series is desingned for high current operation and high flux output applications. -Power LED its thermal management perform exceeds
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71622 UPC Number 60198671622 Description LED Ultra Thin Recessed Canopy Fixture 40W Voltage: 120/208/240/277 Shown with optional recessed mounting Bezel/Trim Cat# 71620 QPL ID # P29AE57D
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500077-0 Report Number: Model: PL04091-001 BXSPCxx4MEE30K-xxxxxx or XSPCxx4MEE30Kxxxxxx Date: 8/5/2014 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08270-001A BXSPR-HO-HT-3ME-60W-57K-UL w/ XA-SPR3BLS Date: 05/07/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side INDEPENDENT TESTING LABORATORIES, INC. 2 1 0 1.05.1 1.5 2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 20 foot
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL04150-001 BXSPCxx3MEE40K-xxxxxx or Date: 8/8/2014 XSPCxx3MEE40K-xxxxxx Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For:
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100896445 Date: September 26, 2012 REPORT NO. 100896445CRT-001 TEST OF ONE LED
More informationCat# LED High Bay
Cat# 71403 LED High Bay Model: 71403 Input Voltage Input Current Input Power Power Factor 100-277VAC 50/60HZ 1.7A Max 144 W PF 0.92 OVERALL LAMP Luminance 17371 LM PARAMETERS Luminous Efficiency 118 LM/W
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09300-001A ARE-EHO-3M-xx-12-E-UL-xx-1000-xxxx Date: 09/16/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationTest Report. Report Number: L14121 Date: Nov 20, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L14121 Date: Nov 20, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay With Clear Polycarbonate Lens Unit manufacturer: Dialight Corporation
More informationSPECIFICATIONS FOR COB SERIES WHITE LED
SPECIFICATIONS FOR COB SERIES WHITE LED Model:Metal COB SERIES LIGHTNING Customer Part No:TMN1-16-xxxx-5802AA0 DATE: 2018/11/05 REV. No.: VERSION A00 1 Features: * Compact high flux density light source
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS350U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationNVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A
LM-79-08 Test Report For SIMKAR CORPORATION (Brand Name: ) LED Lamp Model name(s): SALXS450U1 Model differences: N/A Test & Report By: Johnson Sun Engineer: Johnson Sun Date:Oct.26, 2015 Review By: Manager:
More informationIES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM
IES LM-79-08 MEASUREMENT AND TEST REPORT For Eiko Limited 23220 W. 84th Street,Shawnee, KS, USA Test Model: LEDP-13WPAR30/NFL/830-DIM Report Type: Test Engineer: Electrical and Photometric tests including:
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL08473-001A SA21-16027MDFD-12DE26-1 Date: 5/18/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09299-001A ARE-EHO-AF-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code 500089-0 Report Number: Model: PL10023-003B ARE-EDG-2MB-xx-06-E-UL-xx-525-xxxx-40K Date: 02/28/2017 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
NVLAP Lab Code - Report Number: Model: PL-A HXB-A-UV-L-M-K-UL-xx-xxxx Date: // Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09285-001 ARE-EDG-5M-xx-06-E-UL-xx-700-xxxx-40K Date: 09/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09294-001A ARE-EDG-3M-xx-06-E-UL-xx-700-xxxx Date: 09/14/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For:
More informationPLW3030AE Series 3030 Low Power LED
PLW3030AE Series 3030 Low Power LED Product Datasheet Description Plessey PLW3030AE SMT LEDs are designed for linear tubes, spot lights, bulb replacements and other general lighting applications. The light
More informationMarch 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T
March 26, 2012 Title: TEMPO 21 Report Prepared for: Sviazinvest, OJSC Prepared by: Cree Durham Technology Center (DTC) Ticket Number: 10806-T Co NVLAP lab code 500070-0 The accreditation of the Cree Durham
More informationTest Report. Report Number: L14139 Date: Jul 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727
Test Report Report Number: L14139 Date: Jul 21, 2015 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay Fixture Unit manufacturer: Dialight Corporation Unit model number:
More informationTRNSYS MODELING OF A HYBRID LIGHTING SYSTEM: BUILDING ENERGY LOADS AND CHROMATICITY ANALYSIS
TRNSYS MODELING OF A HYBRID LIGHTING SYSTEM: BUILDING ENERGY LOADS AND CHROMATICITY ANALYSIS Frank W. Burkholder William A. Beckman Sanford A. Klein Doug T. Reindl University of Wisconsin-Solar Energy
More informationIES LM TEST REPORT For EIKO GLOBAL, LLC
NVLAP LAB CODE:201045-0 Shenzhen Anbotek Compliance Laboratory Limited IES LM-79-08 TEST REPORT For EIKO GLOBAL, LLC Report Number: Product Type: Date of Receipt: Date of Test: Date of Report: Product
More informationThe Truth about Neutrality
The Truth about Neutrality How Close is Close Enough By Ron Engvaldsen Schneider Optics Inc. March 23, 2017 For many years, the manufacture of neutral density filters (ND s) has been a challenge for all
More informationReport No.: HZ p. (Lumens) Stabilization Time CRI (K)
Test Summary Sample Tested: ML2LA23LTRBNI827 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 73.6 1737.0 23.61 0.9872 CCT Stabilization Time CRI (K) (Light & Power)
More informationCree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL10277-002B RUL-HT-2ME-C-30K-12-UF-N Date: 02/27/17 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Moxuan Zhu Cree,
More informationRadiometry, photometry, measuring color
Radiometry, photometry, measuring color Lecture notes are done by Géza Várady, based on the lecture notes of Prof. János Schanda varady.geza@mik.pte.hu University of Pécs, Faculty of Engineering and Information
More informationInternational General Certificate of Secondary Education CAMBRIDGE INTERNATIONAL EXAMINATIONS
International General Certificate of Secondary Education CAMBRIDGE INTERNATIONAL EXAMINATIONS PHYSICS 0625/5 PAPER 5 Practical Test OCTOBER/NOVEMBER SESSION 2002 1 hour 15 minutes Candidates answer on
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL03375-001 CPY250-A-xx-D-C-UL-xx-40K or Date: 03/24/2014 BXCCAxD04-UW7 or XCCAxD04-UW7 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation
More information