EE2351 POWER SYSTEM ANALYSIS
|
|
- Elmer McKinney
- 6 years ago
- Views:
Transcription
1 EE351 POWER SYSTEM ANALYSIS A.Ahamed Riazudeen EEE DEPARTMENT 1
2 UNIT I INTRODUCTION
3 Power system network 3
4 SINGLE LINE DIAGRAM It is a diagrammatic representation of a power system in which the components are represented by their symbols. 4
5 COMPONENTS OF A POWER SYSTEM 1.Alternator.Power transformer 3.Transmission lines 4.Substation transformer 5.Distribution transformer 6.Loads 5
6 MODELLING OF GENERATOR AND SYNCHRONOUS MOTOR 1Φ equivalent circuit of generator 1Φ equivalent circuit of synchronous motor 6
7 MODELLING OF TRANSFORMER K E N I E N I ' R R01 R1 R R1 K X X X X X K ' =Equivalent resistance referred to 1 o =Equivalent reactance referred to 1 o 7
8 MODELLING OF TRANSMISSION LINE Π type T type 8
9 MODELLING OF INDUCTION MOTOR ' 1 R r ( 1) s R R R S S ' r X X X =Resistance representing load ' r =Equivalent resistance referred to stator =Equivalent reactance referred to stator 9
10 per unit=actual value/base value Let KVA b =Base KVA kv b =Base voltage Z b =Base impedance in Ω Z b kv kvb KVAb 1000 b MVA b 10
11 Changing the base of per unit quantities Let z = actual impedance(ω) Z b = base impedance (Ω) Z Z Z * MVAb p. u Zb kvb kvb Z MVA b Let kvb, old & MVB, kv & MVB b old b, new b, new represent old base values represent new base values 11
12 Z Z Z b, old p. u, old Z Z * * b, old p. u, old b, old kv Z b, old * MVA kv MVA MVA b, new p. u, new kv b, new (1) () (3) Z kv b, old b, new p. u, new Z p. u, old * * kv MVA b, new b, old MVA 1
13 ADVANTAGES OF PER UNIT CALCULATIONS The p.u impedance referred to either side of a 1Φ transformer is same The manufacturers provide the impedance value in p.u The p.u impedance referred to either side of a 3Φ transformer is same regardless of the 3Φ connections Y- Y,Δ-Y p.u value always less than unity. 13
14 IMPEDANCE DIAGRAM This diagram obtained by replacing each component by their 1Φ equivalent circuit. Following approximations are made to draw impedance diagram 1. The impedance b/w neutral and ground omitted.. Shunt branches of the transformer equivalent circuit neglected. 14
15 REACTANCE DIAGRAM It is the equivalent circuit of the power system in which the various components are represented by their respective equivalent circuit. Reactance diagram can be obtained after omitting all resistances & capacitances of the transmission line from impedance diagram 15
16 REACTANCE DIAGRAM FOR THE GIVEN POWER SYSTEM NETWORK 16
17 PROCEDURE TO FORM REACTANCE DIAGRAM FROM SINGLE DIAGRAM 1.Select a base power kva b or MVA b.select a base voltage kv b 3. The voltage conversion is achieved by means of transformer kv b on LT section= kv b on HT section x LT voltage rating/ht voltage rating 4. When specified reactance of a component is in ohms p.u reactance=actual reactance/base reactance specified reactance of a component is in p.u X kv b, old b, new p. u, new X p. u, old * * kv MVA b, new b, old MVA 17
18 p.u. calculation of 3 winding transformer Zp=Impedance of primary winding Zs =Impedance of secondary winding Zt =Impedance of tertiary winding Short circuit test conducted to find out the above 3 impedances 18
19 1 ' Zp Zps Zpt Z st ' 1 ' Zs Zps Zst Zpt ' 1 ' Zt Z ps Zpt Z st Z ps Z pt ' Z st = Leakage impedance measured in 1 o with o short circuited and tertiary open. = Leakage impedance measured in 1 o with tertiary short circuited and o open. = Leakage impedance measured in o with tertiary short circuited and 1 o open and referred to primary 19
20 PRIMITIVE NETWORK It is a set of unconnected elements which provides information regarding the characteristics of individual elements. it can be represented both in impedance & admittance form 0
21 BUS ADMITTANCE(Y BUS) MATRIX Y BUS can be formed by methods 1.Inspection method.singular transformation Y BUS = Y Y Y Y Y Y Y 1 Y Y n 1 n n n nn 1
22 INSPECTION METHOD For n bus system Diagonal element of Y BUS Y ii n j1 1 Off Diagonal element of Y BUS y ij Y ij y ij
23 SINGULAR TRANSFORMATION METHOD Y BUS = T A y A Where [y]=primitive admittance A=bus incidence matrix 3
24 ALGORITHM FOR FORMATION OF THE BUS IMPEDANCE MATRIX Modification of Zbus matrix involves any one of the following 4 cases Case 1:adding a branch impedance z b from a new bus p to the reference bus Addition of new bus will increase the order the Z bus matrix by 1 Z bus, new z original 0 0 zb (n+1)th column and row elements are zero except the diagonal diagonal element is z b 4
25 Case : adding a branch impedance z b from a new bus p to the existing bus q Addition of new bus will increase the order the Z bus matrix by 1 The elements of (n+1)th column and row are the elements of qth column and row and the diagonal element is Z qq +Z b Case 3:adding a branch impedance z b from an existing bus p to the reference bus The elements of (n+1)th column and row are the elements of qth column and row and the diagonal element is Z qq +Z b and (n+1)th row and column should be eliminated using the following formula Z Z j( n1)( n1) k Zjk, act Zjk j 1,... n; k1,.. n Z( n1)( n 1) 5
26 Case 4:adding a branch impedance z b between existing buses h and q elements of (n+1)th column are elements of bus h column bus q column and elements of (n+1)th row are elements of bus h row bus q row the diagonal element= Z Z Z Z and (n+1)th row and column should be eliminated using the following formula b hh qq hq Z Z j( n1)( n1) k Zjk, act Zjk j1,... n; k1,.. n Z( n1)( n 1) 6
27 UNIT II POWER FLOW ANALYSIS 7
28 BUS CLASSIFICATION 1.Slack bus or Reference bus or Swing bus: V and δ are specified. P and Q are un specified, and to be calculated..generator bus or PV bus or Voltage controlled bus: P and V are specified. Q and δ are un specified, and to be calculated 3.Load bus or PQ bus: P and Q are specified. V and δ are un specified, and to be calculated 8
29 I p pq q q1 ITERATIVE METHOD * p p p P p p * P n Y V S P jq V I P V jq p n Y pq V q1 The above Load flow equations are non linear and can be solved by following iterative methods. q 1.Gauss seidal method.newton Raphson method 3.Fast Decoupled method 9
30 GAUSS SEIDAL METHOD For load bus calculate V and δ from V p k+1 equation V 1 P jq Y V Y V p1 n k1 p p k1 k p k * pq q pq q Y pp () V P q 1 q p 1 For generator bus calculate Q from Q P K+1 equation Q V Y V Y V p1 n k1 k * k1 k p 1*Im() P pq q pq q q1 qp 30
31 Check Q p,cal k+1 with the limits of Q p If Q p,cal k+1 lies within the limits bus p remains as PV bus otherwise it will change to load bus Calculate δ for PV bus from V p k+1 equation Acceleration factor α can be used for faster convergence Calculate change in bus-p voltage V V V k1 k1 k p p p If ΔV max < ε, find slack bus power otherwise increase the iteration count (k) Slack bus power= S S G L 31
32 NEWTON RAPHSON METHOD n P Q V V Y i i i j ij ij i j j 1 n P V V Y co s() i i j ij ij i j j 1 n Q V V Y sin() i i j ij ij i j j 1 P J J 1 Q J 3 J 4 V P P P k sch k i i i Q Q Q k sch k i i i 3
33 Calculate V and δ from the following equation k1 k k i i V V V k1 k k i i i If k Pi Q k i stop the iteration otherwise increase the iteration count (k) 33
34 FAST DECOUPLED METHOD J & J 3 of Jacobian matrix are zero J P V J Q P P J Q Q J V V V 34 ' '' 1 ' 1 '' i i P B V Q B V V P B V Q V B V
35 k1 k k i i V V V k1 k k i i i This method requires more iterations than NR method but less time per iteration It is useful for in contingency analysis 35
36 COMPARISION BETWEEN ITERATIVE METHODS Gauss Seidal Method 1. Computer memory requirement is less.. Computation time per iteration is less. 3. It requires less number of arithmetic operations to complete an iteration and ease in programming. 4. No. of iterations are more for convergence and rate of convergence is slow (linear convergence characteristic. 5. No. of iterations increases with the increase of no. of buses. 36
37 NEWTON RAPHSON METHOD Superior convergence because of quadratic convergence. It has an 1:8 iteration ratio compared to GS method. More accurate. Smaller no. of iterations and used for large size systems. It is faster and no. of iterations is independent of the no. of buses. Technique is difficult and calculations involved in each iteration are more and thus computation time per iteration is large. Computer memory requirement is large, as the elements of jacobian matrix are to be computed in each iteration. Programming logic is more complex. 37
38 FAST DECOUPLED METHOD It is simple and computationally efficient. Storage of jacobian matrix elements are60% of NR method computation time per iteration is less. Convergence is geometric, to 5 iterations required for accurate solutions Speed for iterations is 5 times that of NR method and -3 times of GS method 38
39 UNIT III FAULT ANALYSIS-BALANCED FAULT 39
40 Need for fault analysis To determine the magnitude of fault current throughout the power system after fault occurs. To select the ratings for fuses, breakers and switchgear. To check the MVA ratings of the existing circuit breakers when new generators are added into a system. 40
41 BALANCED THREE PHASE FAULT All the three phases are short circuited to each other and to earth. Voltages and currents of the system balanced after the symmetrical fault occurred. It is enough to consider any one phase for analysis. SHORT CIRCUIT CAPACITY It is the product of magnitudes of the prefault voltage and the post fault current. It is used to determine the dimension of a bus bar and the interrupting capacity of a circuit breaker. 41
42 Short Circuit Capacity (SCC) 0 SCC V I F I F SCC SCC I f V Z 1 3 T T SCC V T Z S Z 3 b,1 T T p. u L, b b,3 T p. u *10 3 * V * S Z MVA MVA / 4
43 Procedure for calculating short circuit capacity and fault current Draw a single line diagram and select common base S b MVA and kv Draw the reactance diagram and calculate the total p.u impedance from the fault point to source (Thevenin impedance Z T ) Determine SCC and I f 43
44 ALGORITHM FOR SHORT CIRCUIT ANALYSIS USING BUS IMPEDANCE MATRIX Consider a n bus network. Assume that three phase fault is applied at bus k through a fault impedance z f Prefault voltages at all the buses are V1 (0) V (0). Vbus (0) Vk (0). Vn (0) Draw the Thevenin equivalent circuit i.e Zeroing all voltage sources and add voltage source V at faulted bus k and draw the reactance k (0) diagram 44
45 The change in bus voltage due to fault is V1.. Vbus Vk. Vn The bus voltages during the fault is V ()(0) F V V bus bus bus The current entering into all the buses is zero.the current entering into faulted bus k is ve of the current leaving the bus k 45
46 V Z I bus bus bus Z11. Z1 k. Z1 n Vbus Zk1. Zkk.() Z kn Ik F Z. Z. Z 0 n1 nk nn V ()(0)() F V Z I F k k kk k V ()() F Z I F I k f k k () F Z V kk k (0) Z V ()(0)() F V Z I F i i ik k f 46
47 UNIT IV FAULT ANALYSIS UNBALANCED FAULTS 47
48 INTRODUCTION UNSYMMETRICAL FAULTS o One or two phases are involved o Voltages and currents become unbalanced and each phase is to be treated individually o The various types of faults are Shunt type faults 1.Line to Ground fault (LG). Line to Line fault (LL) 3. Line to Line to Ground fault (LLG) Series type faults Open conductor fault (one or two conductor open fault) 48
49 FUNDAMENTALS OF SYMMETRICAL COMPONENTS Symmetrical components can be used to transform three phase unbalanced voltages and currents to balanced voltages and currents Three phase unbalanced phasors can be resolved into following three sequences 1.Positive sequence components. Negative sequence components 3. Zero sequence components 49
50 Positive sequence components Three phasors with equal magnitudes, equally displaced from one another by 10 o and phase sequence is same as that of original phasors. V, V, V a1 b1 c1 Negative sequence components Three phasors with equal magnitudes, equally displaced from one another by 10 o and phase sequence is opposite to that of original phasors. V, V, V a b c Zero sequence components Three phasors with equal magnitudes and displaced from one another by 0 o V, V, V a0 b0 c0 50
51 RELATIONSHIP BETWEEN UNBALANCED VECTORS AND SYMMETRICAL COMPONENTS V V V V a a0 a1 a V V V V b b0 b1 b V V V V c c0 c1 c Va Va 0 V b 1 a a V a1 V 1 a a c V a A 1 a a 1 a a Similarly we can obtain for currents also 51
52 SEQUENCE IMPEDANCE Impedances offered by power system components to positive, negative and zero sequence currents. Positive sequence impedance The impedance of a component when positive sequence currents alone are flowing. Negative sequence impedance The impedance of a component when negative sequence currents alone are flowing. Zero sequence impedance The impedance of a component when zero sequence currents alone are flowing. 5
53 SEQUENCE NETWORK SEQUENCE NETWORK FOR GENERATOR positive sequence network negative sequence network Zero sequence network 53
54 SEQUENCE NETWORK FOR TRANSMISSION LINE positive sequence network negative sequence network Zero sequence network 54
55 SEQUENCE NETWORK FOR TRANSFORMER positive sequence network negative sequence network Zero sequence network 55
56 SEQUENCE NETWORK FOR LOAD positive sequence network negative sequence network Zero sequence network 56
57 SINGLE LINE TO GROUND FAULT Consider a fault between phase a and ground through an impedance z f I 0 b I 0 c V a f Z Ia I I I I /3 I a1 a a0 a a1 Ea Z Z Z 3Z 1 0 f 57
58 LINE TO LINE (LL) FAULT Consider a fault between phase b and c through an impedance z f I 0 I a a0 I V V I I a c I I 0 b Z f b c b a1 V V Z I I I f a1 a a1 a1 Ea Z Z 3Z I 1 a b c f Z1 Z 3Z f je 58
59 DOUBLE LINE TO GROUND (LLG) FAULT Consider a fault between phase b and c through an impedance z f to ground I 0 a0 I I I 0 a1 a a0 f V=V(I Z I) 3Z I V V V 3Z I I b c b c f a0 a1 b a0 a1 Ea f Z Z ( Z 3)/( Z Z Z 3) Z f a f 59
60 UNBALANCED FAULT ANALYSIS USING BUS IMPEDANCE MATRIX SINGLE LINE TO GROUND FAULT USING Z bus Consider a fault between phase a and ground through an impedance z f at bus k For a fault at bus k the symmetrical components of fault current I I I V(0) 0 1 k k k k 1 0 f Zkk Zkk Zkk 3Z 60
61 LINE TO LINE (LL) FAULT Consider a fault between phase b and c through an impedance z f 0 Ik 0 I I V(0) 1 k k k 1 f Z kk Z kk Z 61
62 DOUBLE LINE TO GROUND (LLG) FAULT Consider a fault between phase b and c through an impedance z f to ground I I I 1 k k 0 k Z 1 kk V(0) V(0) Z ( Z f 3) Z Z Z 3Z k 0 kk kk 0 kk kk I 1 1 k kk k Zkk V(0) b I() F I I I 1 1 k kk k 0 f Zkk 3Z c k k k Z Z f 6
63 BUS VOLTAGES AND LINE CURRENTS DURING FAULT V () F 0 Z I i ik k V ()(0) F V I Z i i ik k V () F 0 Z I I I I i ik k 0 ij 1 ij ij 0 0 Vi ()() F V j F 0 Z ij 1 1 Vi ()() F V j F 1 Z Vi ()() F V j F Z ij ij 63
64 UNIT V STABILITY ANALYSIS 64
65 STABILITY The tendency of a power system to develop restoring forces equal to or greater than the disturbing forces to maintain the state of equilibrium. Ability to keep the machines in synchronism with another machine 65
66 CLASSIFICATION OF STABILITY Steady state stability Ability of the power system to regain synchronism after small and slow disturbances (like gradual power changes) Dynamic stability Ability of the power system to regain synchronism after small disturbances occurring for a long time (like changes in turbine speed, change in load) Transient stability This concern with sudden and large changes in the network conditions i.e.. sudden changes in application or removal of loads, line switching operating operations, line faults, or loss of excitation. 66
67 Steady state limit is the maximum power that can be transferred without the system become unstable when the load in increased gradually under steady state conditions. Transient limit is the maximum power that can be transferred without the system becoming unstable when a sudden or large disturbance occurs. 67
68 Swing Equation for Single Machine Infinite Bus System The equation governing the motion of the rotor of a synchronous machine where m d m J T T T dt a m e J=The total moment of inertia of the rotor(kg-m ) =Singular displacement of the rotor T m =Mechanical torque (N-m) T e =Net electrical torque (N-m) T a =Net accelerating torque (N-m) 68
69 t m sm m d m dt d sm d m m d dt dt dt J d dt p p p m m a m e Where p m is the shaft power input to the machine p e is the electrical power p a is the accelerating power m 69
70 J d m M p p p dt H M S machine m sm H d m pa pm pe sm dt S machine S machine H d dt s s H f d M f 0 d dt a m e p p p a m e p p p f a m e f p p p 0 0 m max sin dt H H d dt d f 0 d pa dt H dt p.u a H=machine inertia constant p.u δ and ω s are in electrical radian 70
71 Swing Equation for Multimachine System S S m a ch in e system =machine rating(base) =system base Hsystem d pa pm pe p.u H f system dt H machine S S machine system 71
72 Rotor Angle Stability It is the ability of interconnected synchronous machines of a power system to maintain in synchronism. The stability problem involves the study of the electro mechanical oscillations inherent in power system. Types of Rotor Angle Stability 1. Small Signal Stability (or) Steady State Stability. Transient stability 7
73 Voltage Stability It is the ability of a power system to maintain steady acceptable voltages at all buses in the system under normal operating conditions and after being subjected to a disturbance. The major factor for instability is the inability of the power system to meet the demand for reactive power. 73
74 Mid Term Stability It represents transition between short term and long term responses. Typical ranges of time periods. 1. Short term : 0 to 10s. Mid Term : 10 to few minutes 3. Long Term : a few minutes to 10 s of minutes Long Term Stability Usually these problem be associated with 1. Inadequacies in equipment responses.. Poor co-ordination of control and protection equipment. 3. Insufficient active/reactive power reserves. 74
75 Equal Area Criterion This is a simple graphical method to predict the transient stability of two machine system or a single machine against infinite bus. This criterion does not require swing equation or solution of swing equation to determine the stability condition. The stability conditions are determined by equating the areas of segments on power angle diagram. 75
76 Power-angle curve for equal area criterion multiplying swing equation by on both sides Multiplying both sides of the above equation by dt and then integrating between two arbitrary angles δ 0 and δ c 76
77 Once a fault occurs, the machine starts accelerating. Once the fault is cleared, the machine keeps on accelerating before it reaches its peak at δ c, The area of accelerating A1 The area of deceleration is given by A If the two areas are equal, i.e., A 1 = A, then the power system will be stable 77
78 Critical Clearing Angle (δ cr ) maximum allowable value of the clearing time and angle for the system to remain stable are known as critical clearing time and angle. δ cr expression can be obtained by substituting δ c = δ cr in the equation A1 = A Substituting P e = 0 in swing equation Integrating the above equation 78
79 Replacing δ by δ cr and t by t cr in the above equation, we get the critical clearing time as 79
80 Factors Affecting Transient Stability Strength of the transmission network within the system and of the tie lines to adjacent systems. The characteristics of generating units including inertia of rotating parts and electrical properties such as transient reactance and magnetic saturation characteristics of the stator and rotor. Speed with which the faulted lines or equipments can be disconnected. 80
81 Numerical Integration methods Modified Euler s method Runge-Kutta method 81
82 MODIFIED EULER S METHOD Using first derivative of the initial point next point is obtained p dx X the step 1 X0 t t1 t0 t dt Using this x 1p dx/dt at x 1p =f(t 1, x 1p ) Corrected value is d x d x d t p P X d t 0 X 1 X 1 X 0 t d x d x d t p c X d t i X i 1 X i 1 X i t 8
83 Numerical Solution of the swing equation Input power p m =constant At steady state p e =p m, p 0 1 m ax 1 p m sin p1 m ax E ' V X 1 At synchronous speed p 0 max 0 E ' X V 83
84 The swing equation H d f dt d m max sin dt H H p p p f a m e d dt d f 0 d pa dt H dt f p p p Applying Modified Eulers method to above equation p i t1 t0 t d 1 i t dt p d i 1 i t dt i i a 84
85 The derivatives at the end of interval p i p p i i p i a d dt f d p dt H The corrected value p i i p i i c i i c i i d d dt dt t d d dt dt t
86 Runge-Kutta Method Obtain a load flow solution for pretransient conditions Calculate the generator internal voltages behind transient reactance. Assume the occurrence of a fault and calculate the reduced admittance matrix Initialize time count K=0,J=0 Determine the eight constants K f (,) t k k k 1 1 l f (,) t k k k 1 k k k k K 1 k l1 K f1 (,) k k k k K 1 k l1 l f (,) t t k k k k K k l K 3 f1 (,) t k k k k K k l l3 f (,) t k k k k K 3 k l3 K 4 f1 (,) t k k k k K 3 k l3 l4 f (,) t k k k k K 1 K K k 3 K 4 l l l l k 6 6 k k k k
87 Compute the change in state vector Evaluate the new state vector k1 k k k1 k k Evaluate the internal voltage behind transient reactance using the relation E E cos j E sin k 1 k k 1 k k 1 p p p p p Check if t<t c yes K=K+1 Check if j=0,yes modify the network data and obtain the new reduced admittance matrix and set j=j+1 set K=K+1 Check if K<Kmax, yes start from finding 8 constants k k K K K K k k k k l l l l k k k k
B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis
B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester Electrical and Electronics Engineering EE 1352 Power System Analysis (Regulation 2008) Time: Three hours Answer all questions Part A (10
More informationBEE701 POWER SYSTEM ANALYSIS
BEE701 POWER SYSTEM ANALYSIS UNIT I POWER SYSTEM COMPONENTS Power system analysis The evaluation of power system is called as power system analysis Functions of power system analysis To monitor the voltage
More informationKINGS COLLEGE OF ENGINEERING Punalkulam
KINGS COLLEGE OF ENGINEERING Punalkulam 613 303 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING POWER SYSTEM ANALYSIS QUESTION BANK UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A (TWO MARK
More informationEE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION
EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION PART: A 1. Define per unit value of an electrical quantity. Write equation for base impedance with respect to 3-phase system. 2. What is bus admittance
More informationINSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)
INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad - 500 043 ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK Course Name : Computer Methods in Power Systems Course Code : A60222
More informationEE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A
EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A 1. What are the advantages of an inter connected system? The advantages of an inter-connected system are
More informationEE 6501 POWER SYSTEMS UNIT I INTRODUCTION
EE 6501 POWER SYSTEMS UNIT I INTRODUCTION PART A (2 MARKS) 1. What is single line diagram? A Single line diagram is diagrammatic representation of power system in which the components are represented by
More informationSCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008
SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS LECTURE NOTES Transient Stability SPRING SEMESTER, 008 October 7, 008 Transient Stability Transient stability refers to the ability of a synchronous
More informationDHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY Mamalapuram Chennai QUESTION BANK V SEMESTER. EE6501-Power system Analysis
DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY Mamalapuram Chennai DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK V SEMESTER EE6501-Power system Analysis Regulation 2013
More informationSHORT QUESTIONS AND ANSWERS. Year/ Semester/ Class : III/ V/ EEE Academic Year: Subject Code/ Name: EE6501/ Power System Analysis
Srividya colllege of Engg & Tech,Virudhunagar Sri Vidya College of Engineering And Technology Virudhunagar 626 005 Department of Electrical and Electronics Engineering QUESTION BANK SHORT QUESTIONS AND
More informationPOWER SYSTEM STABILITY
LESSON SUMMARY-1:- POWER SYSTEM STABILITY 1. Introduction 2. Classification of Power System Stability 3. Dynamic Equation of Synchronous Machine Power system stability involves the study of the dynamics
More informationECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability
ECE 4/5 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability Spring 014 Instructor: Kai Sun 1 Transient Stability The ability of the power system to maintain synchronism
More informationSSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL
1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Power Systems: Generation, Transmission and Distribution Power Systems: Generation, Transmission and Distribution Power Systems:
More informationFault Analysis Power System Representation
.1. Power System Representation Single Line Diagram: Almost all modern power systems are three phase systems with the phases of equal magnitude and equal phase difference (i.e., 10 o ). These three phase
More informationPower System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India
Power System Stability and Control Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India Contents Chapter 1 Introduction to Power System Stability
More informationModule 3 : Sequence Components and Fault Analysis
Module 3 : Sequence Components and Fault Analysis Lecture 12 : Sequence Modeling of Power Apparatus Objectives In this lecture we will discuss Per unit calculation and its advantages. Modeling aspects
More informationFinal Exam, Second Semester: 2015/2016 Electrical Engineering Department
Philadelphia University Faculty of Engineering Student Name Student No: Serial No Final Exam, Second Semester: 2015/2016 Electrical Engineering Department Course Title: Power II Date: 21 st June 2016 Course
More informationEE 451 Power System Stability
EE 451 Power System Stability Power system operates in synchronous mode Power system is subjected to a wide range of disturbances (small and large) - Loads and generation changes - Network changes - Faults
More informationECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015
ECE 325 Electric Energy System Components 7- Synchronous Machines Instructor: Kai Sun Fall 2015 1 Content (Materials are from Chapters 16-17) Synchronous Generators Synchronous Motors 2 Synchronous Generators
More informationECE 585 Power System Stability
Homework 1, Due on January 29 ECE 585 Power System Stability Consider the power system below. The network frequency is 60 Hz. At the pre-fault steady state (a) the power generated by the machine is 400
More informationExamples of Applications of Potential Functions in Problem Solving (Web Appendix to the Paper)
Examples of Applications of otential Functions in roblem Solving (Web Appendix to the aper) Ali Mehrizi-Sani and Reza Iravani May 5, 2010 1 Introduction otential functions may be exploited to formulate
More informationQUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1
ower ystems ower ystem tability QUETION BANK. A cylindrical rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load
More information1. Introduction. Keywords Transient Stability Analysis, Power System, Swing Equation, Three-Phase Fault, Fault Clearing Time
Energy and Power 17, 7(1): -36 DOI: 1.593/j.ep.1771.3 Numerical Simulations for Transient Stability Analysis of Two-Machine Power System Considering Three-Phase Fault under Different Fault Clearing Times
More informationChapter 8: Unsymmetrical Faults
Chapter 8: Unsymmetrical Faults Introduction The sequence circuits and the sequence networks developed in the previous chapter will now be used for finding out fault current during unsymmetrical faults.
More informationTHE UNIVERSITY OF NEW SOUTH WALES. School of Electrical Engineering & Telecommunications FINALEXAMINATION. Session
Name: Student ID: Signature: THE UNIVERSITY OF NEW SOUTH WALES School of Electrical Engineering & Telecommunications FINALEXAMINATION Session 00 ELEC46 Power System Analysis TIME ALLOWED: 3 hours TOTAL
More informationCHAPTER 2 LOAD FLOW ANALYSIS FOR RADIAL DISTRIBUTION SYSTEM
16 CHAPTER 2 LOAD FLOW ANALYSIS FOR RADIAL DISTRIBUTION SYSTEM 2.1 INTRODUCTION Load flow analysis of power system network is used to determine the steady state solution for a given set of bus loading
More informationEE 581 Power Systems. Admittance Matrix: Development, Direct and Iterative solutions
EE 581 Power Systems Admittance Matrix: Development, Direct and Iterative solutions Overview and HW # 8 Chapter 2.4 Chapter 6.4 Chapter 6.1-6.3 Homework: Special Problem 1 and 2 (see handout) Overview
More informationPOWER SYSTEM STABILITY AND CONTROL
POWER SYSTEM STABILITY AND CONTROL P. KUNDUR Vice-President, Power Engineering Powertech Labs Inc., Surrey, British Columbia Formerly Manager Analytical Methods and Specialized Studies Department Power
More informationGenerators. What its all about
Generators What its all about How do we make a generator? Synchronous Operation Rotor Magnetic Field Stator Magnetic Field Forces and Magnetic Fields Force Between Fields Motoring Generators & motors are
More informationIn the previous chapter, attention was confined
4 4 Principles of Power System CHAPTE CHAPTE 8 Unsymmetrical Fault Calculations 8. Usymmetrical Faults on -Phase System 8. Symmetrical Components Method 8. Operator a 8.4 Symmetrical Components in Terms
More informationA Course Material on EE2351 POWER SYSTEM ANALYSIS
A Course Material on EE2351 POWER SYSTEM ANALYSIS By Mrs. K. Umarani ASSISTANT PROFESSOR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING SASURIE COLLEGE OF ENGINEERING VIJAYAMANGALAM 638 056 Page
More informationChapter 3 AUTOMATIC VOLTAGE CONTROL
Chapter 3 AUTOMATIC VOLTAGE CONTROL . INTRODUCTION TO EXCITATION SYSTEM The basic function of an excitation system is to provide direct current to the field winding of the synchronous generator. The excitation
More informationFault Calculation Methods
ELEC9713 Industrial and Commercial Power Systems Fault Calculation Methods There are two major problems that can occur in electrical systems: these are open circuits and short circuits. Of the two, the
More informationJRE SCHOOL OF Engineering
JRE SCHOOL OF Engineering Class Test-1 Examinations September 2014 Subject Name Electromechanical Energy Conversion-II Subject Code EEE -501 Roll No. of Student Max Marks 30 Marks Max Duration 1 hour Date
More informationLESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES
ET 332b Ac Motors, Generators and Power Systems LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES 1 LEARNING OBJECTIVES After this presentation you will be able to: Interpret alternator phasor diagrams
More informationChapter 8 VOLTAGE STABILITY
Chapter 8 VOTAGE STABIITY The small signal and transient angle stability was discussed in Chapter 6 and 7. Another stability issue which is important, other than angle stability, is voltage stability.
More informationLast Comments on Short-Circuit Analysis
Last Comments on Short-Circuit Analysis.0 Exam summary Work all HW problems and know them; Read notes Read related book sections Topics:. Symmetrical faults (no book section) 2. Zbus building (9.3-9.6)
More informationPower System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur
Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 9 Transmission Line Steady State Operation Welcome to lesson 9, in Power
More informationTransient Stability Analysis of Single Machine Infinite Bus System by Numerical Methods
International Journal of Electrical and Electronics Research ISSN 348-6988 (online) Vol., Issue 3, pp: (58-66), Month: July - September 04, Available at: www.researchpublish.com Transient Stability Analysis
More informationIntroduction to Synchronous. Machines. Kevin Gaughan
Introduction to Synchronous Machines Kevin Gaughan The Synchronous Machine An AC machine (generator or motor) with a stator winding (usually 3 phase) generating a rotating magnetic field and a rotor carrying
More information4.10 Unbalanced fault analysis using Z BUS matrix:
4.10 Unbalanced fault analysis using Z BUS matrix: In the previous section, it is observed that, for fault calculations the Thevenin s equivalent networs, at the fault point, are needed for the three sequence
More informationTransient Stability Assessment and Enhancement Using TCSC with Fuzzy Logic Controller
Transient Stability Assessment and Enhancement Using TCSC with Fuzzy Logic Controller Ali Qasim Hussein Department of Electrical Engineering, Acharya NAgarjuna University, Nagarjuna Nagar,Guntur,522510,Ap,
More informationIGEE 402 Power System Analysis. FINAL EXAMINATION - SAMPLE Fall 2004
IGEE 402 Power System Analysis FINAL EXAMINATION - SAMPLE Fall 2004 Special instructions: - Duration: 80 minutes. - Material allowed: a crib sheet (double sided 8.5 x ), calculator. - Attempt 5 out of
More informationReliability of Bulk Power Systems (cont d)
Reliability of Bulk Power Systems (cont d) Important requirements of a reliable electric power service Voltage and frequency must be held within close tolerances Synchronous generators must be kept running
More informationDynamics of the synchronous machine
ELEC0047 - Power system dynamics, control and stability Dynamics of the synchronous machine Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct October 2018 1 / 38 Time constants and
More informationEE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz
EE 742 Chapter 3: Power System in the Steady State Y. Baghzouz Transmission Line Model Distributed Parameter Model: Terminal Voltage/Current Relations: Characteristic impedance: Propagation constant: π
More informationSECTION 7: FAULT ANALYSIS. ESE 470 Energy Distribution Systems
SECTION 7: FAULT ANALYSIS ESE 470 Energy Distribution Systems 2 Introduction Power System Faults 3 Faults in three-phase power systems are short circuits Line-to-ground Line-to-line Result in the flow
More informationPOWER SEMICONDUCTOR BASED ELECTRIC DRIVES
POWER SEMICONDUCT BASED ELECTRIC DRIVES [Time: 3 Hrs] [Max. Marks: 80] Instructions: Solve any six questions from Q.No (1 or 2), Q.No (3 or 4), Q.No (5 or 6), Q.No (7 or 8), Q.No (9 or 10), Q.No (11 or
More informationELECTRIC POWER CIRCUITS BASIC CONCEPTS AND ANALYSIS
Contents ELEC46 Power ystem Analysis Lecture ELECTRC POWER CRCUT BAC CONCEPT AND ANALY. Circuit analysis. Phasors. Power in single phase circuits 4. Three phase () circuits 5. Power in circuits 6. ingle
More informationCHAPTER 2 DYNAMIC STABILITY MODEL OF THE POWER SYSTEM
20 CHAPTER 2 DYNAMIC STABILITY MODEL OF THE POWER SYSTEM 2. GENERAL Dynamic stability of a power system is concerned with the dynamic behavior of the system under small perturbations around an operating
More informationCHAPTER 6 STEADY-STATE ANALYSIS OF SINGLE-PHASE SELF-EXCITED INDUCTION GENERATORS
79 CHAPTER 6 STEADY-STATE ANALYSIS OF SINGLE-PHASE SELF-EXCITED INDUCTION GENERATORS 6.. INTRODUCTION The steady-state analysis of six-phase and three-phase self-excited induction generators has been presented
More informationPower Flow Analysis. The voltage at a typical bus i of the system is given in polar coordinates by
Power Flow Analysis 4.1 introduction: Power-flow studies are of great importance in planning and designing the future expansion of power systems as well as in determining the best operation of existing
More informationCHAPTER 2 CAPACITANCE REQUIREMENTS OF SIX-PHASE SELF-EXCITED INDUCTION GENERATORS
9 CHAPTER 2 CAPACITANCE REQUIREMENTS OF SIX-PHASE SELF-EXCITED INDUCTION GENERATORS 2.. INTRODUCTION Rapidly depleting rate of conventional energy sources, has led the scientists to explore the possibility
More informationBehaviour of synchronous machine during a short-circuit (a simple example of electromagnetic transients)
ELEC0047 - Power system dynamics, control and stability (a simple example of electromagnetic transients) Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct October 2018 1 / 25 Objectives
More informationA STATIC AND DYNAMIC TECHNIQUE CONTINGENCY RANKING ANALYSIS IN VOLTAGE STABILITY ASSESSMENT
A STATIC AND DYNAMIC TECHNIQUE CONTINGENCY RANKING ANALYSIS IN VOLTAGE STABILITY ASSESSMENT Muhammad Nizam Engineering Faculty Sebelas Maret University (Ph.D Student of Electrical, Electronic and System
More informationCHAPTER 3 ANALYSIS OF THREE PHASE AND SINGLE PHASE SELF-EXCITED INDUCTION GENERATORS
26 CHAPTER 3 ANALYSIS OF THREE PHASE AND SINGLE PHASE SELF-EXCITED INDUCTION GENERATORS 3.1. INTRODUCTION Recently increase in energy demand and limited energy sources in the world caused the researchers
More informationChapter 9: Transient Stability
Chapter 9: Transient Stability 9.1 Introduction The first electric power system was a dc system built by Edison in 1882. The subsequent power systems that were constructed in the late 19 th century were
More informationELEC4612 Power System Analysis Power Flow Analysis
ELEC462 Power Sstem Analsis Power Flow Analsis Dr Jaashri Ravishankar jaashri.ravishankar@unsw.edu.au Busbars The meeting point of various components of a PS is called bus. The bus or busbar is a conductor
More informationIncorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation
Incorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation James Ranjith Kumar. R, Member, IEEE, Amit Jain, Member, IEEE, Power Systems Division,
More informationSECTION 5: POWER FLOW. ESE 470 Energy Distribution Systems
SECTION 5: POWER FLOW ESE 470 Energy Distribution Systems 2 Introduction Nodal Analysis 3 Consider the following circuit Three voltage sources VV sss, VV sss, VV sss Generic branch impedances Could be
More informationEquivalent Circuits with Multiple Damper Windings (e.g. Round rotor Machines)
Equivalent Circuits with Multiple Damper Windings (e.g. Round rotor Machines) d axis: L fd L F - M R fd F L 1d L D - M R 1d D R fd R F e fd e F R 1d R D Subscript Notations: ( ) fd ~ field winding quantities
More information3- BASICS. YTransformation. for balanced load. \V ab 120 = \V bc. \V ab 240 = \V ca \I a 120 = \I b \I a 240 = \I c V ab I a
3- BASICS YTransformation for balanced load Z =3Z Y Balanced 3- Systems \V ab 10 = \V bc \V ab 40 = \V ca \I a 10 = \I b \I a 40 = \I c V ab I a = p 3 V an = p 3 I ab \V ab 30 = \V an \I ab 30 = \I a S
More information(Refer Slide Time: 00:55) Friends, today we shall continue to study about the modelling of synchronous machine. (Refer Slide Time: 01:09)
(Refer Slide Time: 00:55) Power System Dynamics Prof. M. L. Kothari Department of Electrical Engineering Indian Institute of Technology, Delhi Lecture - 09 Modelling of Synchronous Machine (Contd ) Friends,
More informationPower System Stability GENERATOR CONTROL AND PROTECTION
Power System Stability Outline Basis for Steady-State Stability Transient Stability Effect of Excitation System on Stability Small Signal Stability Power System Stabilizers Speed Based Integral of Accelerating
More informationA COMPUTER PROGRAM FOR SHORT CIRCUIT ANALYSIS OF ELECTRIC POWER SYSTEMS
NIJOTECH VOL. 5 NO. 1 MARCH 1981 EJEBE 46 A COMPUTER PROGRAM FOR SHORT CIRCUIT ANALYSIS OF ELECTRIC POWER SYSTEMS BY G.C. EJEBE DEPARTMENT OF ELECTRICAL/ELECTRONIC ENGINEERING UNIVERSITY OF NIGERIA, NSUKKA.
More informationSynchronous Machines
Synchronous Machines Synchronous generators or alternators are used to convert mechanical power derived from steam, gas, or hydraulic-turbine to ac electric power Synchronous generators are the primary
More informationFrom now, we ignore the superbar - with variables in per unit. ψ ψ. l ad ad ad ψ. ψ ψ ψ
From now, we ignore the superbar - with variables in per unit. ψ 0 L0 i0 ψ L + L L L i d l ad ad ad d ψ F Lad LF MR if = ψ D Lad MR LD id ψ q Ll + Laq L aq i q ψ Q Laq LQ iq 41 Equivalent Circuits for
More information, and ignoring all load currents, determine
ECE43 Test 3 Dec 8, 5 Q. (33 pts.) The Zbus for the above 3-bus network with bus as reference, in per unit, is given to be 3.87 j.798 j.8 j Z.798 j.87 j.8 j bus.8 j.8 j j Assuming that the prefault values
More informationLesson 17: Synchronous Machines
Lesson 17: Synchronous Machines ET 332b Ac Motors, Generators and Power Systems Lesson 17_et332b.pptx 1 Learning Objectives After this presentation you will be able to: Explain how synchronous machines
More informationModelling and Analysis of Electric Power Systems
Modelling and Analysis of Electric Power Systems Power Flow Analysis Fault Analysis Power Systems Dynamics and Stability Lecture 227-0526-00, ITET ETH Zürich Göran Andersson EEH - Power Systems Laboratory
More informationECEN 667 Power System Stability Lecture 18: Voltage Stability, Load Models
ECEN 667 Power System Stability Lecture 18: Voltage Stability, Load Models Prof. Tom Overbye Dept. of Electrical and Computer Engineering Texas A&M University, overbye@tamu.edu 1 Announcements Read Chapter
More informationPower Angle & Time Domain Plots 1.0 The power-angle curves
Power Angle & Time Domain Plots 1.0 The power-angle curves Consider a generator connected to an infinite bus through a network, as shown in Fig. 1 below (all in pu). E E NETWORK X V V 0 Fig. 1 We assume
More informationEVALUATION OF THE IMPACT OF POWER SECTOR REFORM ON THE NIGERIA POWER SYSTEM TRANSIENT STABILITY
EVALUATION OF THE IMPACT OF POWER SECTOR REFORM ON THE NIGERIA POWER SYSTEM TRANSIENT STABILITY F. I. Izuegbunam * Department of Electrical & Electronic Engineering, Federal University of Technology, Imo
More informationA. P. Sakis Meliopoulos and George J. Cokkinides Power System Relaying, Theory and Applications. Chapter 8 2 Generator Protection 2
DRAFT and INCOMPLETE Table of Contents from A. P. Sakis Meliopoulos and George J. Cokkinides Power System Relaying, Theory and Applications Chapter 8 Generator Protection 8. Introduction 8. Generator Protection
More informationEEE3405 ELECTRICAL ENGINEERING PRINCIPLES 2 - TEST
ATTEMPT ALL QUESTIONS (EACH QUESTION 20 Marks, FULL MAKS = 60) Given v 1 = 100 sin(100πt+π/6) (i) Find the MS, period and the frequency of v 1 (ii) If v 2 =75sin(100πt-π/10) find V 1, V 2, 2V 1 -V 2 (phasor)
More informationMicro-grid to System Synchronization Based on Pre-Insertion Impedance Method (Version 1.0) By Peter Zhou University of Alberta Jan 30 th, 2015
Micro-grid to System Synchronization Based on Pre-Insertion Impedance Method (Version 1.0) By Peter Zhou University of Alberta Jan 30 th, 2015 Outline 1. What is Synchronization? 2. Synchronization Concerns?
More information7. Transient stability
1 7. Transient stability In AC power system, each generator is to keep phase relationship according to the relevant power flow, i.e. for a certain reactance X, the both terminal voltages V1and V2, and
More informationThe synchronous machine (SM) in the power system (2) (Where does the electricity come from)?
1 The synchronous machine (SM) in the power system (2) (Where does the electricity come from)? 2 Lecture overview Synchronous machines with more than 2 magnetic poles The relation between the number of
More informationEE Branch GATE Paper 2010
Q.1 Q.25 carry one mark each 1. The value of the quantity P, where, is equal to 0 1 e 1/e 2. Divergence of the three-dimensional radial vector field is 3 1/r 3. The period of the signal x(t) = 8 is 0.4
More informationThe Operation of a Generator on Infinite Busbars
The Operation of a Generator on Infinite Busbars In order to simplify the ideas as much as possible the resistance of the generator will be neglected; in practice this assumption is usually reasonable.
More information1 Unified Power Flow Controller (UPFC)
Power flow control with UPFC Rusejla Sadikovic Internal report 1 Unified Power Flow Controller (UPFC) The UPFC can provide simultaneous control of all basic power system parameters ( transmission voltage,
More informationTransients on Integrated Power System
Chapter 3 Transients on Integrated Power System 3.1 Line Dropping and Load Rejection 3.1.1 Line Dropping In three phase circuit capacitance switching, the determination of the voltage trapped after switching
More informationQ. 1 Q. 25 carry one mark each.
Q. 1 Q. 25 carry one mark each. Q.1 Given ff(zz) = gg(zz) + h(zz), where ff, gg, h are complex valued functions of a complex variable zz. Which one of the following statements is TUE? (A) If ff(zz) is
More informationPower System Analysis
Power System Analysis Power Flow Analysis Fault Analysis Power System Dynamics and Stability Lecture 227-0526-00, ITET ETH Zürich Göran Andersson EEH - Power Systems Laboratory ETH Zürich September 2012
More informationYou know for EE 303 that electrical speed for a generator equals the mechanical speed times the number of poles, per eq. (1).
Stability 1 1. Introduction We now begin Chapter 14.1 in your text. Our previous work in this course has focused on analysis of currents during faulted conditions in order to design protective systems
More informationEnhancement of transient stability analysis of multimachine power system
WWJMRD 2016; 2(6): 41-45 www.wwjmrd.com Impact Factor MJIF: 4.25 e-issn: 2454-6615 Oyediran Oyebode Olumide Department of Computer Engineering, Osun State Polytechnic Iree, Osun State, Nigeria Ogunwuyi
More informationANALYSIS OF SUBSYNCHRONOUS RESONANCE EFFECT IN SERIES COMPENSATED LINE WITH BOOSTER TRANSFORMER
ANALYSIS OF SUBSYNCHRONOUS RESONANCE EFFECT IN SERIES COMPENSATED LINE WITH BOOSTER TRANSFORMER G.V.RAJASEKHAR, 2 GVSSNS SARMA,2 Department of Electrical Engineering, Aurora Engineering College, Hyderabad,
More informationCURENT Course Power System Coherency and Model Reduction
CURENT Course Power System Coherency and Model Reduction Prof. Joe H. Chow Rensselaer Polytechnic Institute ECSE Department November 1, 2017 Slow Coherency A large power system usually consists of tightly
More information2 Power System Network Matrices I
Power System Analysis Power System Network Matrices I. INRODUCION he various terms used in Graph heory are presented in this chapter. Formulation of different network matrices are discussed. Primitive
More informationDynamic simulation of a five-bus system
ELEC0047 - Power system dynamics, control and stability Dynamic simulation of a five-bus system Thierry Van Cutsem t.vancutsem@ulg.ac.be www.montefiore.ulg.ac.be/~vct November 2017 1 / 16 System modelling
More informationCahier Technique N 13 Principe de réduction des courants d enclenchement des transformateurs
Cahier Technique N 13 Principe de réduction des courants d enclenchement des transformateurs Numerical transformer inrush current minimizer Principle of the operation Rev 1.0 Document version information
More informationFaults on Electrical System. A Research
Faults on Electrical System A Research Presented to Electrical Engineering School of Engineering and Architecture Mindanao University of Science and Technology Cagayan de Oro City In partial fulfilment
More informationGATE 2010 Electrical Engineering
GATE 2010 Electrical Engineering Q.1 Q.25 carry one mark each 1. The value of the quantity P, where P = xe dx, is equal to (A) 0 (B) 1 (C) e (D) 1/e 2. Divergence of the three-dimensional radial vector
More informationCHAPTER 8 UNSYMMETRICAL FAULTS
CHAPTER 8 UNSYMMETRCAL FAULTS The sequence circuits and the sequence networks developed in the previous chapter will now be used or inding out ult current during unsymmetrical ults. Speciically we are
More informationAn Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy
An Introduction to Electrical Machines P. Di Barba, University of Pavia, Italy Academic year 0-0 Contents Transformer. An overview of the device. Principle of operation of a single-phase transformer 3.
More informationECE 422 Power System Operations & Planning 7 Transient Stability
ECE 4 Power System Operations & Planning 7 Transient Stability Spring 5 Instructor: Kai Sun References Saaat s Chapter.5 ~. EPRI Tutorial s Chapter 7 Kunur s Chapter 3 Transient Stability The ability of
More informationCHAPTER 5 STEADY-STATE ANALYSIS OF THREE-PHASE SELF-EXCITED INDUCTION GENERATORS
6 CHAPTER 5 STEADY-STATE ANALYSIS OF THREE-PHASE SELF-EXCITED INDUCTION GENERATORS 5.. INTRODUCTION The steady-state analysis of six-phase SEIG has been discussed in the previous chapters. In this chapter,
More informationLO 1: Three Phase Circuits
Course: EEL 2043 Principles of Electric Machines Class Instructor: Dr. Haris M. Khalid Email: hkhalid@hct.ac.ae Webpage: www.harismkhalid.com LO 1: Three Phase Circuits Three Phase AC System Three phase
More informationMinimax Approximation Synthesis in PSS Design by Embedding
Minimax Approximation Synthesis in PSS Design by Embedding Gravitational Search Algorithm Dr. Akash Saxena Department of Electrical Engineering Swami Keshvanand Institute of Technology Jaipur, India Power
More informationECEN 667 Power System Stability Lecture 15: PIDs, Governors, Transient Stability Solutions
ECEN 667 Power System Stability Lecture 15: PIDs, Governors, Transient Stability Solutions Prof. Tom Overbye Dept. of Electrical and Computer Engineering Texas A&M University, overbye@tamu.edu 1 Announcements
More information