Radioactivity. is related to de/dx. The range, R, is defined by the integral of de/dx:
|
|
- Lenard Ray
- 6 years ago
- Views:
Transcription
1 Advanced Physics Labs 9/11/08 Radioactivity Modern physics began with the study of radioactivity by Becquerel in Subsequent investigations by the Curies, Rutherford, and others quickly revealed that nuclear decays produce three distinct kinds of ionizing radiation: alpha, beta, and gamma. In this experiment you will study the operation of radiation detectors and the penetrating properties of these three forms of ionizing radiation. You will also be required to apply basic methods of data analysis. Background In about 1903 Rutherford showed that there are three types of ionizing radiation by separating them in a magnetic field. Alpha particles are helium nuclei ejected from heavy nuclei. Beta radiation consists of electrons or positrons emitted in the weak decays of unstable nuclei. Atomic electrons can also be emitted as secondary particles as a result of decays. Gamma radiation is made up of high energy photons emitted in transitions from excited states of nuclei formed by emission of a beta particle or electron capture. These three forms of radiation are absorbed very differently in materials. For alpha and beta radiations traveling through matter, the interaction of the particles charges with the atomic electrons of the material results in energy deposited by ionization of the atoms. The result is energy loss by the charged particle at a rate de/dx that depends on the particle mass and charge, its energy, and the density and nature of the material. In general, de/dx for a non-relativistic particle is proportional to z 2 m/e where m is its mass and ze its charge. Therefore α particles have much greater de/dx. The particle s range for an initial energy E 0 is related to de/dx. The range, R, is defined by the integral of de/dx: R de E 0 = dx 0 dx Alpha particles have large de/dx and a correspondingly short range R in any material a few cm in air and fractions of a millimeter in matter. For example, a piece of paper or aluminum foil can stop alpha particles. Beta particles have ranges of a few meters in air or a few millimeters in aluminum. Gamma rays are photons and therefore do not lose energy by ionization as α s and β s do. Gamma rays interact with atomic electrons and nuclei in three distinct ways: 1. The photoelectric effect results in the absorption of the photon and transfer of its energy to an electron. The photoelectric effect is an inelastic process because some energy is lost to overcome the binding energy of the electron in the material. This binding energy is the work function and is significant for visible photons, but generally negligible for gamma ray photons. 2. The Compton effect is the scattering of a photon from electrons in the material and results in energy transfer to the electron and a gamma ray photon of reduced energy propagating along a new trajectory at some angle θ relative to the initial trajectory. 3. The conversion of a photon into an electron-positron pair is possible if the photon energy exceeds MeV = 2m e c 2.
2 2 In each of these processes, the incident gamma ray disappears, and the resulting energetic electron (and positron in the case of pair production) deposits energy in the material at the rate de/dx. Gamma ray interactions in matter, therefore, result in attenuation of the gamma ray flux or intensity. For a beam of gamma rays with intensity I(x) where x is the position in an absorber, there is a decrease of intensity di, due to the absorption in a very small thickness dx : di dx = λi where λ is a constant called the linear absorption coefficient in the given material. The solution to this well-known differential equation is an exponential: I(x) = I 0 e λx The length / λ at which I = I 0 /2, is called the half thickness. The absorption of alpha and beta radiation, which is due to the interaction with electrons, depends almost entirely upon the density of electrons through which the particles pass. This density, about one electron per proton in the material, changes very little over the entire range of elements. Therefore the thickness in centimeters is usually replaced by the areal density, ρx. Thus de/dx will be in units of MeV/(gm/cm 2 ) and x in units of gm/cm 2. Reading Knoll, Radiation Detection and Measurement, Chapters 5-7 Bevington & Robinson, Data Reduction and Error Analysis, Chapters 1 and 2 on Statistics and data analysis Apparatus A Geiger tube usually consists of a fine tungsten wire placed axially along the axis of a conducting cylinder. These are sealed in a container that is filled with some gas, such as argon, at about one-tenth of an atmosphere of pressure. The central wire is at a positive potential of several hundred volts with respect to the cylinder. In the Geiger tube used in this experiment, the inside wall of the glass is covered with silver, thus eliminating a separate conducting cylinder. In order to understand the action of the Geiger counter, consider it connected as in Figure 1. Figure 1. A schematic diagram of the Geiger tube and circuit. The time constant for recovery of the high voltage after a pulse is τ=rc, where C is the capacitance of the tube.
3 3 The Geiger tube is connected to a high-voltage source through a resistor R of the order of 10 8 ohms to limit the current. The capacitor C represents the total capacitance of the tube, the input capacitance of the circuit to which the central wire is connected, plus any externally added capacitance. The output of the tube may be connected to an oscilloscope or an amplifier. Consider now what happens when ionizing radiation such as alpha or beta particle, or a pulse of gamma rays enters the tube. The ionization removes electrons from the atoms of the gas, producing free electrons and positive ions. The electrons move toward the positive central wire and the positive ions to the negative cylinder of the tube. If the applied voltage V is small, ~100 volts, no further ionization takes place, and the charge collected on the wire is that produced by the initial ionizing event. The tube is then behaving as an ionization chamber. The free electrons produced by the initial ionizing radiation are accelerated by the electric field in Geiger tube. If the electric field is large enough, these electrons gain sufficient energy between collisions to remove more electrons from neutral atoms in the gas. These secondary electrons are then accelerated and produce more ionization, so that an avalanche takes place. The gas amplifies the original ionization by some factor A called the gas amplification factor. In a limited region of voltage the tube behaves as a proportional counter; that is, the amplification factor A is a constant, and the output charge is proportional to the charge produces by the initial ionizing event. If the voltage is increased further, the tube eventually reaches the Geiger region where the output charge saturates and is almost independent of the charge produced in the initial ionizing event. Before the tube can successfully register a second ionizing event, it must have completely recovered from the first ionizing event. Owing to the presence of ultraviolet photons in the gas discharge, electrons can be ejected from the negative electrode. These electrons can sustain the discharge. The discharge will continue indefinitely unless there is some means of quenching it. There are a number of ways of quenching the discharge, among which are a high resistance R in the electronic circuit, or a small amount of organic vapor mixed with the gas in the tube. This organic vapor absorbs the ultraviolet photons without the production of electrons and thus quenches the discharge. The Geiger region continues for about 200 volts above the threshold voltage, and then the tube goes into continuous discharge that may damage the tube. In a radiation counter the small pulses from the Geiger tube are amplified so that they are above threshold to trigger a comparator circuit and a pulse shaper, which produces a pulse of constant width and amplitude if the pulse from the tube is above a certain threshold. These pulses are then counted in a scaler. A Geiger counter is used to measure or to count the number of ionizing events produced by a source of radiation. Excellent discussions of Geiger tubes and circuits are to be found in the books by Price and Knoll. The response of your Geiger counter depends on tube voltage. With voltage up to a few hundred volts, the amplification is small, and ionizing events do not register scaler counts. Just below the voltage at which the tube reaches the Geiger region, the efficiency increases steadily and then reaches a plateau, after which it becomes almost independent of the applied voltage. This plateau extends for a hundred or so volts. Do not go beyond the plateau because the tube continu-
4 4 ously discharges and can be seriously damaged. It is usual to operate the Geiger tube from 75 to 100 volts above the starting voltage in about the middle of the plateau. There will always be background even when all known radioactive sources are removed from the vicinity. Background is due to cosmic rays and local radioactive contamination, for example, 40 K in concrete. Their background rate is ~30 counts/minute and can be determined by counting with all sources removed. Things to measure Three radioactive sources are supplied: Polonium-210, Strontium-90, and Cobalt-60. (Others are also available.) The decay rate of these sources is a fraction of a microcurie (1 μci =3.7x10 4 decays/sec). They are sealed (except for the alpha source) and are safe if handled carefully. Polonium-210 ( 210 Po) decays by α-particle emission with E = 5.3 MeV and a half life of 0.39 yr; 90 Sr beta decays with E <2.27 MeV, half life 28 yr; while 60 Co gamma decays with E =1.17 MeV and half life 5.2 yr. When using the sources, make sure you put the business end toward the Geiger tube. Usually this is the unlabelled side, but it s a good idea to check by turning the source the other way and seeing which side gives the higher counting rate. A good web site for information on radionuclides is Also supplied are lead, aluminum, and polyethylene (plastic) absorbers of various mass densities. Be sure to record all pertinent details as you go along. The Characteristic Curve of the Counter We use several different Geiger counters. In this write-up, we ll assume you are using one of the older ones by The Nucleus. Check with the instructor for additional information if you are using a different one. NOTE: In order to count α's the entrance window of the Geiger tube must be very thin, and is therefore very fragile. Do not touch the window or allow anything to contact it. Connect the instrument to 115-volt a.c. power. Turn the High Voltage to 0. Connect the Geiger tube in its housing to the connector on the back of the control box. Set the power switch to the ON position. Reset the counter. Set the time control for 1 minute of counting and test the builtin scaler using the test push button. Set the time control for continuous (Manual) counting and place the gamma-ray source below the tube. Use an external digital voltmeter connected to the Meter terminals on the back to monitor the high voltage. [Be careful not to touch these terminals. The current is small but you can get a significant shock!] Place a gamma source several cm. from the Geiger counter. Slowly increase the voltage and note the reading at which the first counts appear. This is the starting voltage. The operating voltage, which is in the middle of the plateau, should be about 100 volts above this starting voltage. Never increase the voltage more than about 200 volts above the starting voltage on these Geiger tubes as they may go into continuous discharge and be damaged. With the gamma source in place, raise the voltage in successive small steps of about 10 volts from below the starting voltage, and record the number of counts per minute at each setting.
5 5 You may wish to use larger steps in the plateau region. Do not go beyond about 250 volts above the starting voltage. Do not allow the counter to run wild, i.e., discharge continuously. To reduce statistical fluctuations, use an arrangement such that you get ~1000 counts per minute on the plateau. Plot count rate vs. HV and indicate the starting voltage and plateau on your graph. Determine the slope of the plateau region. Calculate the quality factor defined as Q (1 / N )ΔN / ΔV ) in units of %/(100 volts). Here, N is the average count rate in the middle of the plateau region and ΔN/ΔV is the slope in the plateau. For subsequent measurements, use an operating voltage 100 V above the starting voltage. The Electrical Signal from the Counter Use an oscilloscope to observe the size and shape of the pulses from the Geiger counter. For these measurements it is best to use an analog scope rather than a digital one because the pulses vary significantly in amplitude. Use a coaxial cable to connect from the Oscilloscope connector on the back of the scaler box to the Channel 1 input of the scope. [This is the signal from the Geiger tube, but with a capacitor in series to remove the high voltage. Do not plug the scope directly to the Geiger tube!] Set the scope trigger to trigger on Channel 1 with negative pulses with slope negative. In order to see the true shape of the signals from the Geiger tube you may have to put a 1 KΩ resistor across the input. With the HV set to the middle of the plateau and an α source under the detector, you should see negative pulses ~100 mv about 2 μsec wide. Sketch the pulses. The total charge in the pulse is Q = idt= (V / R)dt where R is the 1 KΩ resistor across the scope input. Estimate Q for the pulses. From this, estimate how many electrons are collected at the anode to form the pulse. Suppose the pulse is initiated by a polonium α that leaves half of its energy in the Geiger tube. It requires ~20 ev of energy to ionize an atom. How many electrons are released by the α particle? Estimate the amplification factor in the avalanche. Observe the pulses from the Geiger tube with a β/γ source. Are the pulses more or less consistent in pulse height? Explain. Make a plot of pulse height vs. operating voltage from the middle of the plateau down to an HV such that the pulses are too small to observe. Make a plot of pulse height vs. HV on a log-log scale. Does the behavior near threshold appear to be a power law? With the HV on the plateau and a high activity β/γ source close to the detector, look at the pulses with the scope sweep speed ~0.5 millisec/div. Look for second pulses following the one that triggered the scope. Is there a minimum time before which a 2 nd pulse can appear? Do the 2 nd pulses change amplitude if they come later? Explain this behavior in your lab report. Be sure to disconnect the cable to the oscilloscope for the next measurements as it will affect the counting rate significantly.
6 6 Counting Statistics This section requires the lowest possible count rates. Therefore, remove all known radioactive sources from the vicinity of the apparatus so that the counts are entirely due to cosmic rays and radioactivity in the materials of the room. The count rate should be about 20 counts/minute. These background counts can be readily counted and a series of successive measurements may be compared with the values predicted from Poisson and Gaussian distributions. Measure the number of counts for >100 successive time intervals of 3 seconds each. Since the count rate is low, those can be done without stopping the counter. Simply record the scaler events every 3 seconds. The difference between successive numbers gives the required number of counts. Find the number of intervals in which zero, one two, etc., counts per interval and compare to a Poisson distribution, the expected parent distribution. See the Appendix for a brief tutorial on the Poisson distribution. Place the gamma-ray source at such a distance that the scaler reads approximately 200 counts per minute. Observe and record a series of ten readings of the scaler of thirty-second duration. For the ten readings, determine the mean μ, the standard deviation σ, and the standard deviation of the mean. Make a table to compare your results with that expected for a Poisson and a Gaussian distribution. Establish that about 63% of the observed data lie within the range μ - σ and μ + σ. Remove the source and record the background counts for several intervals of at least two minutes. Compute the mean background rate and compare it to that with the source. Shielding With the radioactive sources removed, determine the background in counts per minute. Place the gamma source in one of the lower positions, away from the tube. Determine the number of counts per minute with no absorber present, then with varying thicknesses of lead placed between the source and the Geiger tube. Record the thicknesses and the source distance. Check the background reading occasionally. From the counts per minute recorded for the lead absorbers, subtract the background count rate (beginning and end) and determine the net count rate with uncertainties. Record the results in a tabular form giving the thickness of the absorber, the count rate, and the net count rate with uncertainties in units of counts/minute. Plot the log of count rate vs. absorber thickness. Determine the half thickness d 1/2 (in units of cm and mg/cm 2 and the linear absorption coefficient λ (in units of cm -1 and cm 2 /mg). Determine the range (in units of cm and mg/cm 2 ) of polonium alpha particles in air as follows: Start at a source distance of about one cm and determine the count rate. Increase the distance from the detector entrance window in small steps until the background rate is reached. Note that the count rate decreases with increasing distance, but the product of rate multiplied by distance squared should initially remain approximately constant. To take out the geometric factor, plot rate x (distance 2 ) vs. distance. When estimating distances, be aware that the anode of the Geiger tube does not extend all the way to the thin window, so that the detector is effectively about 0.6 cm away from the thin window. Take this into account in the (distance) 2 term. De-
7 7 termine the distance in air (in cm) required to stop the alpha particles, and convert this distance to mg/cm 2 of air. The range of beta particles is difficult to measure with a radioactive source because the beta energy is continuous up to some maximum energy, called the endpoint energy. The beta energy spectrum shows that the highest energy, longest range betas are relatively unlikely. Explore shielding of beta radiation with this caveat in mind. Try using aluminum absorbers and look for a sharp drop in rate when the highest energy β s start ranging out. Dead Time The dead time or resolving time of a Geiger counter is the time after a count is registered during which the system cannot detect a subsequent count even if ionization occurs within the counter. Dead time arises due to the time it takes the ionized gas to recover after an event and due to the electronics. It is the minimum time between two events in the Geiger tube that can be distinctly resolved. The dead time for a particular system depends on several factors including: the design of the counter itself, the gas used in the Geiger tube, the voltage applied, and even the count rate. If the dead time is τ in seconds, and the observed count rate is N' counts per second (cps), then the counter is insensitive for a fraction of real time equal to N 'τ seconds per second. Since the emission of particles from a radioactive source is of a random nature, there is as much a chance for pulses to occur during this time interval as during any other equal time interval. In general, the resolution time for the counting system is of the order of a few hundred microseconds. The counting losses due to the dead time are, therefore, expected to be on the order of a few percent for 100 cps. A special pair of sources shaped like quarter moons is available. Arrange them facing the Geiger tube so that the count rate from either is several hundred cps. Measure N ' I and N ' 2, the rate from each of the sources when placed separately in their positions. Then place both sources at the same time in the original positions and measure N 12, the rate with both. Because of counting losses, the number of counts per second from the two sources together, N 12, is less than the sum of the two separately,(n ' 1 + N ' 2 ). You can show that the approximate value of the resolution time is: τ N ' 1 + N ' 2 N ' 12 2(N ' 1 N ' 2 ) Compare this with the minimum time before which a 2 nd pulse can appear that was measured previously. Source Activity Determine the activity of a 90 Sr source. Carefully measure the diameter of the Geiger tube face and the distance to the source so you can estimate the solid angle subtended by the detector. Estimate both statistical and systematic uncertainties. (See the handout on Statistics and Analysis
8 8 on our web site.) Compare your result to that stamped on the source holder corrected for the decay of activity since the source was purchased. Repeat for 137 Cs. Appendix: The Poisson and Gaussian Distributions The Poisson distribution is appropriate for random processes that have a small probability of happening. A good example is the radioactive decay of a nucleus in this experiment. If the lifetime is ~years and your measurement takes ~1 minute, then the probability that the nucleus will decay during your measurement is very small and the Poisson distribution "works". The Poisson distribution is given by P(x) = μ x e μ / x! where μ is the mean number of counts in the measurement interval, x is the observed number of counts, and P is the probability of observing that number. For example, suppose we measure the background rate 100 times for 3-second intervals. As a shortcut, we can get the mean rate by measuring the rate for a long time. Suppose we get 100 counts in a 300 s interval, so that we expect a mean μ of 1.0 counts in a 3 s interval. Then the probability of getting 0 counts in one measurement is ! e 1 = e 1 = Thus if we took 100 runs, we would expect to get 0 counts about 37 times. The Gaussian or normal distribution is valid when μ is large(>>>1) and we make a large number of measurements. (We'll settle for ~10!) The probability for a Gaussian distribution is 2 1 x μ 1 P(x) = σ 2π e 2 σ where σ is the standard deviation. For radioactive decay, σ μ where μ is the mean number of counts in our measurement interval. Thus if we had an average of counts per measurement, μ =100.0 and σ =10.0. The probability distribution will be a bell-shaped curve centered at μ =100.0 counts with a width determined by σ. Excel has built-in functions, Poisson and NormDist that you can use to make the tables. A good source for more information on data reduction and error analysis is the book of Bevington and Robinson.
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics PART I Geiger Tube: Optimal Operating Voltage and Resolving Time Objective: To become acquainted with the operation and characteristics
More informationCopyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy
Experiment VI Gamma Ray Spectroscopy 1. GAMMA RAY INTERACTIONS WITH MATTER In order for gammas to be detected, they must lose energy in the detector. Since gammas are electromagnetic radiation, we must
More informationOverview: In this experiment we will study the decay of a radioactive nucleus, Cesium. Figure 1: The Decay Modes of Cesium 137
Radioactivity (Part I and Part II) Objectives: To measure the absorption of beta and gamma rays To understand the concept of half life and to measure the half life of Ba 137* Apparatus: Radioactive source,
More informationLab NUC. Determination of Half-Life with a Geiger-Müller Counter
Lab NUC Determination of Half-Life with a Geiger-Müller Counter Object: Apparatus: To understand the concept of half-life; to become familiar with the use of a Geiger-Müller counter; to determine the half-lives
More informationRadioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay
Radioactivity INTRODUCTION The most common form of radiation is the electromagnetic wave. These waves include low energy radio waves, microwaves, visible light, x-rays, and high-energy gamma rays. Electromagnetic
More informationRadioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory
PC1144 Physics IV Radioactivity 1 Objectives Investigate the analogy between the decay of dice nuclei and radioactive nuclei. Determine experimental and theoretical values of the decay constant λ and the
More informationTHE GEIGER-MULLER TUBE AND THE STATISTICS OF RADIOACTIVITY
GMstats. THE GEIGER-MULLER TUBE AN THE STATISTICS OF RAIOACTIVITY This experiment examines the Geiger-Muller counter, a device commonly used for detecting and counting ionizing radiation. Various properties
More informationAbsorption and Backscattering ofβrays
Experiment #54 Absorption and Backscattering ofβrays References 1. B. Brown, Experimental Nucleonics 2. I. Kaplan, Nuclear Physics 3. E. Segre, Experimental Nuclear Physics 4. R.D. Evans, The Atomic Nucleus
More informationRadioactivity APPARATUS INTRODUCTION PROCEDURE
Radioactivity APPARATUS. Geiger Counter / Scaler. Cesium-7 sealed radioactive source. 0 pieces of paper. 8 aluminum plates. 0 lead plates 6. Graph paper - log-log and semi-log 7. Survey Meter ( unit for
More informationhν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?
Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important
More informationGLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY
GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY ABSORBED DOSE: The amount of energy absorbed, as a result of radiation passing through a material, per unit mass of material. Measured in rads (1 rad
More informationPhysics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter
Physics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter Theory The nuclei of radioactive atoms spontaneously decay in three ways known as alpha, beta, and gamma decay. Alpha decay occurs
More informationAbsorption and Backscattering of β-rays
Experiment #54 Absorption and Backscattering of β-rays References 1. B. Brown, Experimental Nucleonics 2. I. Kaplan, Nuclear Physics 3. E. Segre, Experimental Nuclear Physics 4. R.D. Evans, The Atomic
More informationJazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440
Jazan University College of Science Physics Department جاهعة جازان كلية العل وم قسن الفيزياء Lab Manual Nuclear Physics (2) 462 Phys 8 th Level Academic Year: 1439/1440 1 Contents No. Name of the Experiment
More informationEEE4106Z Radiation Interactions & Detection
EEE4106Z Radiation Interactions & Detection 2. Radiation Detection Dr. Steve Peterson 5.14 RW James Department of Physics University of Cape Town steve.peterson@uct.ac.za May 06, 2015 EEE4106Z :: Radiation
More informationPhysics 1000 Half Life Lab
Physics 1000 Half Life Lab Determination of Half-Life with a Geiger-Müller Counter Object: Apparatus: To understand the concept of half-life; to become familiar with the use of a Geiger-Müller counter;
More informationE. K. A. ADVANCED PHYSICS LABORATORY STATISTICS OF COUNTING WITH A GEIGER COUNTER ARTIFICIAL RADIOACTIVITY
E. K. A. ADVANCED PHYSICS LABORATORY STATISTICS OF COUNTING WITH A GEIGER COUNTER ARTIFICIAL RADIOACTIVITY 1. INTRODUCTION The Geiger Müller (GM tube) detector for ionizing particles operates on the principle
More informationOverview: In this experiment we study the decay of a radioactive nucleus, Cesium 137. Figure 1: The Decay Modes of Cesium 137
Radioactivity (Part I and Part II) 7-MAC Objectives: To measure the absorption of beta and gamma rays To understand the concept of half life and to measure the half life of Ba 137* Apparatus: Radioactive
More informationRadioactivity III: Measurement of Half Life.
PHY 192 Half Life Spring 2010 1 Radioactivity III: Measurement of Half Life. Introduction This experiment will once again use the apparatus of the first experiment, this time to measure radiation intensity
More informationRadioactivity and Ionizing Radiation
Radioactivity and Ionizing Radiation QuarkNet summer workshop June 24-28, 2013 1 Recent History Most natural phenomena can be explained by a small number of simple rules. You can determine what these rules
More informationRADIOACTIVITY MATERIALS: PURPOSE: LEARNING OBJECTIVES: DISCUSSION:
RADIOACTIVITY This laboratory experiment was largely adapted from an experiment from the United States Naval Academy Chemistry Department MATERIALS: (total amounts per lab) small bottle of KCl; isogenerator
More information3 Radioactivity - Spontaneous Nuclear Processes
3 Radioactivity - Spontaneous Nuclear Processes Becquerel was the first to detect radioactivity. In 1896 he was carrying out experiments with fluorescent salts (which contained uranium) and found that
More informationIntroduction. Principle of Operation
Introduction Ionizing radiation that is associated with radioactivity cannot be directly detected by our senses. Ionization is the process whereby the radiation has sufficient energy to strip electrons
More informationChapter Four (Interaction of Radiation with Matter)
Al-Mustansiriyah University College of Science Physics Department Fourth Grade Nuclear Physics Dr. Ali A. Ridha Chapter Four (Interaction of Radiation with Matter) Different types of radiation interact
More informationEXPERIMENT FOUR - RADIOACTIVITY This experiment has been largely adapted from an experiment from the United States Naval Academy, Annapolis MD
EXPERIMENT FOUR - RADIOACTIVITY This experiment has been largely adapted from an experiment from the United States Naval Academy, Annapolis MD MATERIALS: (total amounts per lab) small bottle of KCl; isogenerator
More informationAt the conclusion of this lesson the trainee will be able to: a) Write a typical equation for the production of each type of radiation.
RADIOACTIVITY - SPONTANEOUS NUCLEAR PROCESSES OBJECTIVES At the conclusion of this lesson the trainee will be able to: 1. For~, p and 7 decays a) Write a typical equation for the production of each type
More informationMEASURING THE LIFETIME OF THE MUON
B6-1 MEASURING THE LIFETIME OF THE MUON Last Revised September 19, 2006 QUESTION TO BE INVESTIGATED What is the lifetime τ of a muon? INTRODUCTION AND THEORY Muons are a member of a group of particles
More informationEXPERIMENT 11: NUCLEAR RADIATION
Introduction: radioactive nuclei. third is electromagnetic radiation. EXPERIMENT 11: NUCLEAR RADIATION In this lab, you will be investigating three types of emissions from Two types of these emissions
More informationRADIOACTIVITY IN THE AIR
RADIOACTIVITY IN THE AIR REFERENCES M. Sternheim and J. Kane, General Physics (See the discussion on Half Life) Evans, The Atomic Nucleus, pp. 518-522 Segre, Nuclei and Particles, p. 156 See HEALTH AND
More informationSCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION
SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system
More informationAnalytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee
Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee Module - 2 Radioisotopes Techniques Lecture - 3 GM Counting and
More informationTHE COMPTON EFFECT Last Revised: January 5, 2007
B2-1 THE COMPTON EFFECT Last Revised: January 5, 2007 QUESTION TO BE INVESTIGATED: How does the energy of a scattered photon change after an interaction with an electron? INTRODUCTION: When a photon is
More informationPh 3504 Radioactive Decay
Ph 3504 Radioactive Decay Required background reading Attached are several pages from an appendix on the web for Tipler. You do not have to read them all (unless you want to), but make sure you read the
More informationRadiation and Radioactivity. PHYS 0219 Radiation and Radioactivity
Radiation and Radioactivity 1 Radiation and Radioactivity This experiment has four parts: 1. Counting Statistics 2. Gamma (g) Ray Absorption Half-length and shielding 3. 137 Ba Decay Half-life 4. Dosimetry
More information6. Atomic and Nuclear Physics
6. Atomic and Nuclear Physics Chapter 6.2 Radioactivity From IB OCC, prepared by J. Domingues based on Tsokos Physics book Warm Up Define: nucleon atomic number mass number isotope. Radioactivity In 1896,
More informationCHARGED PARTICLE INTERACTIONS
CHARGED PARTICLE INTERACTIONS Background Charged Particles Heavy charged particles Charged particles with Mass > m e α, proton, deuteron, heavy ion (e.g., C +, Fe + ), fission fragment, muon, etc. α is
More informationRadiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons
Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na Ellen Simmons 1 Contents Introduction Review of the Types of Radiation Charged Particle Radiation Detection Review of Semiconductor
More informationEmphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)
LECTURE 5: INTERACTION OF RADIATION WITH MATTER All radiation is detected through its interaction with matter! INTRODUCTION: What happens when radiation passes through matter? Emphasis on what happens
More informationRANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706
(revised 10/20/10) RANGE OF ALPHAS Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706 Abstract A silicon solid state detector is used to measure the energy of alphas which
More informationLAB 13 - RADIOACTIVITY, BETA, AND GAMMA RAYS
237 Name Date Partners LAB 13 - RADIOACTIVITY, BETA, AND GAMMA RAYS OBJECTIVES Learn about radioactivity. Understand the random nature of radioactivity. Investigate the 1/r 2 dependence of particle decay.
More informationBasic physics Questions
Chapter1 Basic physics Questions S. Ilyas 1. Which of the following statements regarding protons are correct? a. They have a negative charge b. They are equal to the number of electrons in a non-ionized
More informationMASS ATTENUATION COEFFICIENT OF LEAD
OBJECTIVE MASS ATTENUATION COEFFICIENT OF LEAD The objective of this experiment is to measure the mass attenuation coefficient of lead by manipulating Beer-Lambert s law of attenuation. INTRODUCTION Background
More informationRADIOACTIVITY, BETA, AND GAMMA RAYS
July 14, 2008 Radioactivity 1 Name Date Partners RADIOACTIVITY, BETA, AND GAMMA RAYS Classic atomic and radioactive symbol OBJECTIVES OVERVIEW Learn about radioactivity. Understand the random nature of
More informationDETECTORS. I. Charged Particle Detectors
DETECTORS I. Charged Particle Detectors A. Scintillators B. Gas Detectors 1. Ionization Chambers 2. Proportional Counters 3. Avalanche detectors 4. Geiger-Muller counters 5. Spark detectors C. Solid State
More informationScintillation Detector
Scintillation Detector Introduction The detection of ionizing radiation by the scintillation light produced in certain materials is one of the oldest techniques on record. In Geiger and Marsden s famous
More informationNuclear Physics and Astrophysics
Nuclear Physics and Astrophysics PHY-30 Dr. E. Rizvi Lecture 4 - Detectors Binding Energy Nuclear mass MN less than sum of nucleon masses Shows nucleus is a bound (lower energy) state for this configuration
More informationParticle Energy Loss in Matter
Particle Energy Loss in Matter Charged particles loose energy when passing through material via atomic excitation and ionization These are protons, pions, muons, The energy loss can be described for moderately
More informationLab 14. RADIOACTIVITY
Lab 14. RADIOACTIVITY 14.1. Guiding Question What are the properties of different types of nuclear radiation? How does nucelar decay proceed over time? 14.2. Equipment 1. ST360 Radiation Counter, G-M probe
More informationcharge. Gamma particles turned out to be electromagnetic radiation, the same as light, but with much higher energy.
Simple, sensitive Geiger counter Radioactivity is a fascinating subject. The more you learn about it, the more questions there are to ask! This project is simple to construct and relatively inexpensive,
More informationPHYS 3650L - Modern Physics Laboratory
PHYS 3650L - Modern Physics Laboratory Laboratory Advanced Sheet Photon Attenuation 1. Objectives. The objectives of this laboratory exercise are: a. To measure the mass attenuation coefficient at a gamma
More informationSensors and Detectors Part 2
Revision 1 December 2014 Sensors and Detectors Part 2 Instructor Guide Reviewed by: Cassandra Bitler 11/3/2014 Project Manager, OGF Date Approved by: Robert Coovert 11/3/2014 Manager, INPO Learning Development
More informationUnit 6 Modern Physics
Unit 6 Modern Physics Early Booklet E.C.: + 1 Unit 6 Hwk. Pts.: / 46 Unit 6 Lab Pts.: / 16 Late, Incomplete, No Work, No Units Fees? Y / N Essential Fundamentals of Modern Physics 1. A photon s energy
More informationb) Connect the oscilloscope across the potentiometer that is on the breadboard. Your instructor will draw the circuit diagram on the board.
Geiger Counter Experiments and The Statistics of Nuclear Decay Using a Geiger Mueller tube, there are a number of experiments we can do. In the classroom there are two different types of Geiger Counters:
More informationModern Physics Laboratory Beta Spectroscopy Experiment
Modern Physics Laboratory Beta Spectroscopy Experiment Josh Diamond and John Cummings Fall 2009 Abstract In this experiment, electrons emitted as a result of the radioactive beta decay of 137 55 Cs are
More information11 Gamma Ray Energy and Absorption
11 Gamma Ray Energy and Absorption Before starting this laboratory, we must review the physiological effects and the proper use of the radioactive samples you will be using during the experiment. Physiological
More informationReview of Particle Properties: (http://pdg.lbl.gov/ ). See the review section on Cosmic Rays under Astrophysics and Cosmology.
XI: Cosmic Rays I. References E. Fermi, Nuclear Physics, Notes compiled by Orear, Rosenfeld, and Schluter, Revised Edition, The University of Chicago Press, 195, chapter on Cosmic Rays, pp. 215-224. Review
More informationEnergy loss of alpha particles - Prelab questions
Energy loss of alpha particles - Prelab questions 1. Write down the decay path from 226 Ra to 206 Pb. Show the intermediate nuclides and the nuclear reactions which cause each transformation (α/β ± decay).
More informationRadiation Detection and Measurement
Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron
More informationPHYS 3446 Lecture #12
PHYS 3446 Lecture #12 Wednesday, Oct. 18, 2006 Dr. 1. Particle Detection Ionization Detectors MWPC Scintillation Counters Time of Flight 1 Announcements Next LPCC Workshop Preparation work Each group to
More informationFranck-Hertz Experiment in Neon/Hg
Franck-Hertz Experiment in Neon/Hg Equipment Franck-Hertz tube (Ne or Hg) & Operating Unit Analog oscilloscope Many Banana cables; 1 BNC cables; 2 BNC-Banana Plug connector Graphing paper Theory This experiment
More informationEXAMINATION QUESTIONS (6)
1. What is a beta-particle? A a helium nucleus B a high-energy electron C four protons D two neutrons EXAMINATION QUESTIONS (6) 2. The diagram shows part of a circuit used to switch street lamps on and
More informationChapter 30 Nuclear Physics and Radioactivity
Chapter 30 Nuclear Physics and Radioactivity 30.1 Structure and Properties of the Nucleus Nucleus is made of protons and neutrons Proton has positive charge: Neutron is electrically neutral: 30.1 Structure
More informationPLK VICWOOD K.T. CHONG SIXTH FORM COLLEGE Form Seven AL Physics Radioactivity
AL Physics/Radioactivity/P.1 PLK VICWOOD K.T. CHONG SIXTH FORM COLLEGE Form Seven AL Physics Radioactivity Radioactivity Properties of α, β and γ radiations Detectors Random nature of decay Natural nuclear
More informationSECTION A Quantum Physics and Atom Models
AP Physics Multiple Choice Practice Modern Physics SECTION A Quantum Physics and Atom Models 1. Light of a single frequency falls on a photoelectric material but no electrons are emitted. Electrons may
More informationThe Franck-Hertz Experiment Physics 2150 Experiment No. 9 University of Colorado
Experiment 9 1 Introduction The Franck-Hertz Experiment Physics 2150 Experiment No. 9 University of Colorado During the late nineteenth century, a great deal of evidence accumulated indicating that radiation
More informationEQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar
Modern Physics Laboratory Beta Spectroscopy Experiment In this experiment, electrons emitted as a result of the radioactive beta decay of Cs-137 are measured as a function of their momentum by deflecting
More informationGamma Spectroscopy. References: Objectives:
Gamma Spectroscopy References: G.F. Knoll, Radiation Detection and Measurement (John Wiley & Sons, New York, 2000) W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-to Approach,
More informationSiPM & Plastic Scintillator
SiPM & Plastic Scintillator Silicon photomultiplier coupled to plastic scintillator Lodovico Lappetito SiPM_PlasticScint_ENG - 28/04/2016 Pag. 1 Table of contents Introduction... 3 Plastic Scintillators...
More informationFigure 1. Decay Scheme for 60Co
Department of Physics The University of Hong Kong PHYS3851 Atomic and Nuclear Physics PHYS3851- Laboratory Manual A. AIMS 1. To learn the coincidence technique to study the gamma decay of 60 Co by using
More informationAlpha decay usually occurs in heavy nuclei such as uranium or plutonium, and therefore is a major part of the radioactive fallout from a nuclear
Radioactive Decay Radioactivity is the spontaneous disintegration of atomic nuclei. This phenomenon was first reported in 1896 by the French physicist Henri Becquerel. Marie Curie and her husband Pierre
More informationMeasuring Cosmic Ray Muon Decay Constant and Flux
WJP, PHY381 (2015) Wabash Journal of Physics v3.3, p.1 Measuring Cosmic Ray Muon Decay Constant and Flux R.C. Dennis, D.T. Tran, J. Qi, and J. Brown Department of Physics, Wabash College, Crawfordsville,
More informationUniversity of Michigan Physics : Advanced Laboratory Notes on RADIOACTIVITY January 2007
University of Michigan Physics 441-442: Advanced Laboratory Notes on RADIOACTIVITY January 2007 1. As usual in the lab, you are forced to learn in several categories at the same time. Your goals in this
More informationNUCLEAR SPECTROMETRY
INTRODUCTION RADIOACTIVITY (Revised:1-24-93) The nuclei of certain atoms are stable and under ordinary circumstances, stable nuclei do not undergo change. The nuclei of other atoms are unstable. These
More informationPhysics 201: Experiment #1 Franck-Hertz Experiment
Physics 201: Experiment #1 Franck-Hertz Experiment Carl Adams Winter 2004 Purpose To demonstrate that electrons colliding with gaseous mercury atoms lose energy in discrete amounts. Nobel Prize Winner
More informationAbsolute activity measurement
Absolute activity measurement Gábor Veres, Sándor Lökös Eötvös University, Department of Atomic Physics January 12, 2016 Financed from the financial support ELTE won from the Higher Education Restructuring
More informationPhys 243 Lab 7: Radioactive Half-life
Phys 243 Lab 7: Radioactive Half-life Dr. Robert MacDonald The King s University College Winter 2013 Abstract In today s lab you ll be measuring the half-life of barium-137, a radioactive isotope of barium.
More informationActivity 11 Solutions: Ionizing Radiation II
Activity 11 Solutions: Ionizing Radiation II 11.1 Additional Sources of Ionizing Radiation 1) Cosmic Rays Your instructor will show you radiation events in a cloud chamber. Look for vapor trails that do
More informationAbsorption of Gamma Rays
Introduction Absorption of Gamma Rays In this experiment, the absorption coefficient of gamma rays passing through several materials is studied. The materials will be compared to one another on their efficacy
More informationMultiple Choice Questions
Nuclear Physics & Nuclear Reactions Practice Problems PSI AP Physics B 1. The atomic nucleus consists of: (A) Electrons (B) Protons (C)Protons and electrons (D) Protons and neutrons (E) Neutrons and electrons
More informationParticle Energy Loss in Matter
Particle Energy Loss in Matter Charged particles, except electrons, loose energy when passing through material via atomic excitation and ionization These are protons, pions, muons, The energy loss can
More informationQuestion Bank. Nuclear Physics
Nuclear Physics 1. State one difference between a chemical change and a nuclear change. Ans. A chemical change takes place due to transfer/sharing of orbital electrons of atoms of different elements, whereas
More information9 Nuclear decay Answers to exam practice questions
Pages 173 178 Exam practice questions 1 X-rays are quanta of energy emitted when electrons fall to a lower energy level, and so do not emanate from the nucleus Answer D. 2 Alpha particles, being the most
More informationABSORPTION OF BETA AND GAMMA RADIATION
ABSORPTION OF BETA AND GAMMA RADIATION The purpose of this experiment is to understand the interaction of radiation and matter, and the application to radiation detection and shielding Apparatus: 137 Cs
More informationGeneral Overview of Gas Filled Detectors
GAS-FILLED DETECTOR General Overview of Gas Filled Detectors Gas-Filled Detectors Ion chamber Proportional counter G-M (Geiger-Miller) counter Diagram of a Generic Gas-Filled Detector A Anode High-voltage
More informationFYSP106/K3 GEIGER & MÜLLER TUBE. 1 Introduction. 2 The equipment
FYSP106/K3 GEIGER & MÜLLER TUE 1 Introduction In this measurement you get familiar with Geiger-Müller tube. The dead time, the range of beta-radiation in medium and the activity of the radiation source
More informationThe Franck-Hertz Experiment
The Franck-Hertz Experiment 1/30/06 The Franck-Hertz experiment, first undertaken shortly after Bohr s theory of the atom was presented, provided one of the early indications that atoms had discrete energy
More informationRadiation Detection. 15 th Annual OSC Readiness Training Program.
Radiation Detection 15 th Annual OSC Readiness Training Program www.oscreadiness.org GM Detectors 15 th Annual OSC Readiness Training Program www.oscreadiness.org 1 A closer look 15 th Annual OSC Readiness
More informationExperiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado
Experiment 6 1 Introduction The Compton Effect Physics 2150 Experiment No. 6 University of Colorado In some situations, electromagnetic waves can act like particles, carrying energy and momentum, which
More informationMeasurement of Mean μ-lifetime
Measurement of Mean μ-lifetime Neha Dokania* *INO Graduate Training Programme, TIFR Abstract: The average muon lifetime is determined in the experiment by stopping muons in a plastic scintillator, where
More informationRadionuclide Imaging MII Detection of Nuclear Emission
Radionuclide Imaging MII 3073 Detection of Nuclear Emission Nuclear radiation detectors Detectors that are commonly used in nuclear medicine: 1. Gas-filled detectors 2. Scintillation detectors 3. Semiconductor
More informationChapter 16: Ionizing Radiation
Chapter 6: Ionizing Radiation Goals of Period 6 Section 6.: To discuss unstable nuclei and their detection Section 6.2: To describe the sources of ionizing radiation Section 6.3: To introduce three types
More informationPhysics 3204 UNIT 3 Test Matter Energy Interface
Physics 3204 UNIT 3 Test Matter Energy Interface 2005 2006 Time: 60 minutes Total Value: 33 Marks Formulae and Constants v = f λ E = hf h f = E k + W 0 E = m c 2 p = h λ 1 A= A T 0 2 t 1 2 E k = ½ mv 2
More informationExperiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.
Chapter 1 Photoelectric Effect Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect. History The photoelectric effect and its understanding
More information1 The Cathode Rays experiment is associated. with: Millikan A B. Thomson. Townsend. Plank Compton
1 The Cathode Rays experiment is associated with: A B C D E Millikan Thomson Townsend Plank Compton 1 2 The electron charge was measured the first time in: A B C D E Cathode ray experiment Photoelectric
More information5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom
5 Atomic Physics 1. Radioactivity 2. The nuclear atom 1. In a fission reactor, which particle causes a Uranium-235 nucleus to split? A. alpha-particle B. gamma ray C. neutron D. proton 2. A radioactive
More informationRadioactivity. General Physics II PHYS 111. King Saud University College of Applied Studies and Community Service Department of Natural Sciences
King Saud University College of Applied Studies and Community Service Department of Natural Sciences Radioactivity General Physics II PHYS 111 Nouf Alkathran nalkathran@ksu.edu.sa Outline Radioactive Decay
More informationDetermining the Efficiency of a Geiger Müller Tube
Determining the Efficiency of a Geiger Müller Tube Introduction Richard Born Northern Illinois University Operations Management and Information Systems The percent efficiency (ɛ of a Geiger Müller (G M)
More informationCosmic Rays Detector. Use of Coincidence Detector for Measures of Cosmic Rays. Lodovico Lappetito. RivelatoreRaggiCosmici_ENG - 6/22/2015 Page 1
Cosmic Rays Detector Use of Coincidence Detector for Measures of Cosmic Rays Lodovico Lappetito RivelatoreRaggiCosmici_ENG - 6/22/2015 Page 1 Table of Contents Design and Components... 3 Detector Design...
More informationPHYS 391 Lab 2b: Counting Statistics
Key Concepts Ionizing Radiation Counting Statistics Poisson Distribution Inverse Square Law 2.1 Introduction PHYS 391 Lab 2b: Counting Statistics This lab will explore the statistical properties of counting
More informationPhysics 248, Spring 2009 Lab 6: Radiation and its Interaction with Matter
Name Section Physics 48, Spring 009 Lab 6: Radiation and its Interaction with Matter Your TA will use this sheet to score your lab. It is to be turned in at the end of lab. To receive full credit you must
More information