MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

Size: px
Start display at page:

Download "MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content"

Transcription

1 Content Introduction Page 01 - Feature Function / Specification Page 02 - Electronic Specification Page 03 Hardware Information - PCB Scheme Page 04 - Jumper / Connectors Description Page 04 - Operation Note Page 04 - Warning Alarm Description Page 05 - PCB Dimension Page 05 File Name Format Page 06 Operation Mode/Priority Rule Page 07 - Player Mode Page 08 - Trigger Mode Code Table Direct Single Mode Page bit(x8) Binary Mode Page 09 9 bit Binary Mode Page 09 ASCII UART Mode Page bit(x8) Binary Mode Page 11-9 bit Binary Mode Page 15 Housing Information - Metal Box Dimension Page 23 Hwan Maw Technology Co., Ltd. Tel.: Fax.: hmt_sales@hmt.com.tw

2 Introduction V control etc CM-SD300 Digital Voice Module can play MP3 files, functioning as a message repeater, vending machine, broadcast system in the public, arrival/elevator announcement for transportation, parking equipment, security alarm, industrial Its sampling rate can reach to 48KHz and compressed bit rate can reach to 320K Bit/s. Apply SDHC(SD2.0)-high capacity SD card (max.:16gb SD card )to store voice files without extra edit software. The quantity of voice files depends on the capacity of a SD card. be up to 2000 voice files. [Note] Not support a SD card with a folder/folders inside. Maximum can VCM-SD300 can also be connected to the outer devices like push button, motion sensor, PLC RELAY and dry contact closures. Beside its controllable built-in 2-watt amplifier, it can be equipped with an external one. Volume, Treble, Bass online control functions are also provided. Play modes for selection: Player mode Trigger modes (Direct Single Mode, 8bit Binary Mode, 9bit Binary Mode, ASCII UART Mode). Feature Product Photo Maximum quantity of MP3 files: Player Mode: 2000 Files. Trigger Mode: Direct Single Mode: Max: 8 Files 8+1bit(X8) Binary Mode: Max: 254 Files 9bit Binary Mode: Max: 510 Files ASCII UART Mode: Max: 2000 Files Built-in 32 channels for serial mode announcement Priority announcing structure--supporting the announcement resuming function (announcement interruption) Apply Disk Volume ID-marking designated operation mode without assisting setting files Warning alarms for indicating the situation system error and malfunction - 1 -

3 Function / Specification Input Trigger Pin number Input Trigger Acknowledge Exterior Response Signal Sampling Rate BIT RATE / kbit Max. Quantity of Message Max. Quantity of voice files Input Trigger Property Setting 8 pins, Photo coupler isolated Low Busy Signal Output (OC / Low) 16KHz / 22KHz / 24KHz / 32 KHz / 44.1KHz / 48KHz 32kbit~320kbit 2000 messages (Please refer to the trigger modes) 2000 voice files (Depend on the SD card capacity) Level / Unhold / Priority Trigger Mode Support / Input Pins Description / Maximum Quantity of Message Player Mode X0-X8 (Player Function Key) 2000 Director Single Mode X0-X7 (X8 Stop Playing) 8 Binary Mode (8Bit) X0-X7, Strobe: X8 254 Binary Mode (9Bit) X0-X7 510 Serial Mode (ASCII UART) Rx

4 Electronic Specification Power Supply DC 12~36 V (DC-DC) Voice Format MPEG file (*.MP3) Amplifier Output 2 Watt, Ro = 4 ohm Consumption (Audio Output) 36mA at DC 24 V Consumption (stand-by mode) 24mA at DC 24V Trigger Inputs De-bounce Time 80ms at least Watch Dog Function Yes Voltage Reverse Protection Yes TVS Protection Yes Temperature for Operation 0-50 Line Out Yes Volume Adjustment Yes (VR & Digital adjustment by ASCII) Serial Baud Rate & Format 2400 bps / 4800 bps / 9600 bps / bps, N, 8,1 Serial Signal Level RS-232 PCB Dimension (L x W) 150 x 87.5 (mm) Metal Box (Optional) Yes - 3 -

5 PCB Scheme D B C G A F H E Voice Input Trigger: CN10: Trigger Input X0-X7 A CN11: Tx Serial Signal Output Rx: Serial Signal Input (RS-232 level) BZ: -Busy Signal Output X8: Trigger Input Sp+ / Sp- : Audio Output VIN: DC12~36V GND: Ground (0V) B CN7: To Connect Switch component, normal right side need short Normal set PIN at SW C J2: Normal set at 5V D CN3: DV24V Power In E CN2: Speaker Connector F SD Card Socket G J1: System Reset H Volume Control Operation Have the connections between the power and amplifier done. When the power is on, two short sounds are heard from the VCM-SD300 digital voice module. The sounds mean the module itself and the format of the SD card are functional, ready to receive the signals to play the voices. If not hearing two short sounds, please check the connections

6 Warning Alarm Description Message Sound Description Start-up Sound Two short sounds No Memory Card One long, one short sounds No SD card / insertion flaw SD card format error Two long, two short sounds Incorrect file format in the SD card No files for playing Two long, one short sounds Files in the SD card are not MP3 ones. No files exist! System Malfunction One long, two short sounds Suggest send the module back for check Start System Renew Finish System Renew One short sound One long sound PCB Dimension - 5 -

7 File Name Format Short File Name Format:The file name is composed of four English letters/numbers(at most). No space between the letters/numbers. (Or it ll be regarded as a long file name.) (See Diagram 1) The extension name is composed of three English letters/numbers (at most). No space between the letters/numbers. Not allowed to use capital and small letters together. Suggest to use capitalized English letters/numbers in the file name and the extension one! (The extension name,.mp3, is the only valid format for the system.) No this limitation in Player Mode. Users can define a long / short file name. If combined with ASCII UART mode, the file name has to be a short one. Short/Long File Name Format Chart for each trigger mode: Format Short File Format Player Mode Long File Format Direct Single Mode 8 + 1bit Binary 9 bit Binary Mode ASCII UART Mode Diagram 1:Short File format Diagram 2:Long File format Disk Volume ID (DVID) Apply Disk Volume ID mark, designating the operation mode. (This is for player mode+ascii UART mode) - 6 -

8 Operation Mode Disk Volume ID (DVID) Operation Mode Standard Mode Non-Priority Mode [Note.2] Player Mode (MBX) Blank / MBX χ Director Single Mode (BS) BS BS bit Binary Mode (B8) B8 B8-9 bit Binary Mode (B9) B9 B9- ASCII UART Mode (AUxxx) [Note1] AU24 / AU48 / AU96 / AU192 χ Mixable Trigger Mode Player Mode + ASCII UART Mode (9600bps) 96 or MBX96 χ Direct Single Mode + ASCII UART Mode (9600bps) BS96 BS bit Binary Mode + ASCII UART Mode (9600bps) B896 B bit Binary Mode + ASCII UART Mode (4800bps) B948 B bit Binary Mode + ASCII UART Mode (9600bps) B996 B9-96 [Note1] 24 means 2400bps, 48 means 4800bps, 96 means 9600bps, 192 means 19200bps; Format N-8-1 [Note2]Placing behind the Mode(EX:BS 96) means to inactivate the priority rule. It functions in the modes like BS,B8,B9,BS+ASCII,B8+ASCII,B9+ASCII. Mixable Trigger Mode & Priority Player Mode Direct Single Mode 8 + 1bit Binary Mode 9 bit Binary Mode ASCII UART Mode (a) Player Mode V (e>a) (b) Direct Single Mode V (b>e) (c) 8 + 1bit Binary Mode V (c>e) (d) 9 bit Binary Mode V (d>e) (e) ASCII UART Mode V (e>a) V (b>e) V (c>e) V (d>e) Priority Rule : In Direct Single Mode : X0 > X1 > X2 > X3 > X4 > X5 > X6 > X7 > X8. In Binary Mode, the minor value in two-digit has the priority > In ASCII UART Mode, first-come, first-play. Depending on the entry order. * In a mixture mode:mbx96 ASCII UART Mode>Player Mode BS96 Direct Single Mode> ASCII UART Mode B bit Binary Mode> ASCII UART Mode B996 9bit Binary Mode > ASCII UART Mode - 7 -

9 ( 1 ) Player Mode Function Key Description X0 Play Level X1 Pause Level X2 Play the previous file (PREV) Edge X3 Play the next file (NEXT) Edge X4 Random [Set Random before PLAY ] Level X5 Single Repeat Level X6 Volume Down Edge X7 Volume Up Edge X8 Mute Level * Level: Signal has to be held in order to keep the action continue. * Edge: Signal only needs to be triggered once to keep the action. ( 2 ) Trigger Mode Direct Single Mode *should be in a short file name format Direct Single Mode (Max: 8 files) Trigger Pin Default file X MP3 X1 X2 X3 X4 X5 X6 X7 X MP MP MP MP MP MP MP3 Stop playing - 8 -

10 8+1bit(X8) Binary Mode *should be in a short file name format 8 + 1bit(X8) Binary Mode (Max.: 254 files) X7 X6 X5 X4 X3 X2 X1 X0 Default file null MP MP MP MP3 ~ 0251.MP MP MP MP Stop playing [Note] In X7~X0, "1" means triggered while "0" means not, which isn t related to the voltage level. X8:"1" means REPEAT mode. X8:"1" means triggered and play. 9bit Binary Mode *should be in a short file name format 9 bit Binary Mode (Max: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file null MP MP MP MP3 ~ 0507.MP MP MP MP Stop playing [Note] In X8~X0, "1" means triggered while "0" means not, which isn t related to the voltage level

11 ASCII UART Mode (Max.:2000Files) ASCII UART Mode [Note] (Max: 2000 files) Order Argument Description P Valid File Names (0001.MP3 ~ 2000.MP3) Play the designated file (Omit the extension name when key in) V 000 ~ 254 Volume Adjustment: Max.(254), Mute(000), Default(234) E Null Stop playing & to clear files in PlayQueue ST Frequency augment Treble Setting (Refer to Attachment 1) SB Frequency augment Bass Setting (Refer to Attachment 1) Eg.: * ASCII command stream 0x0A is the ending symbol. P x0A ---> Play 0001.MP3 file P x0A ---> play 0005.MP3, 0008.MP3, 0103.MP3 files in order E 0x0A ---> Cease playing V 000 0x0A ---> Mute V 223 0x0A ---> Volume Adjustment ST A 2 0x0A ---> Set 10KHz augment 3 db SB 9 A 0x0A ---> Set 90Hz augment 10 db Treble/Base Setting Treble Base Frequency Default Amplified Default Frequency Default Amplified Default 0Hz db 7 20Hz 2 not in use 0 1KHz 1 9 db 6 30Hz 3 1 db 1 2KHz db 5 40Hz 4 2 db 2 3KHz 3 6 db 4 50Hz 5 3 db 3 4KHz db 3 60Hz 6 4 db 4 5KHz 5 3 db 2 70Hz 7 5 db 5 6KHz db 1 80Hz 8 6 db 6 7KHz 7 not in use 0 90Hz 9 7 db 7 8KHz db 9 100Hz A 8 db 8 9KHz 9-3 db A 110Hz B 9 db 9 10KHz A -4.5 db B 120Hz C 10 db A 11KHz B -6 db C 130Hz D 11 db B 12KHz C -7.5dB D 140Hz E 12 db C 13KHz D -9 db E 150Hz F 13 db D 14KHz E -10.5dB F 14 db E 15KHz F 15 db F

12 Code Table 8 + 1bit(X8) Binary Mode (Max.: 254 files) X7 X6 X5 X4 X3 X2 X1 X0 Default file X7 X6 X5 X4 X3 X2 X1 X0 Default file Null MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-11 -

13 8 + 1bit(X8) Binary Mode (Max.: 254 files) X7 X6 X5 X4 X3 X2 X1 X0 Default file X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-12 -

14 8 + 1bit(X8) Binary Mode (Max.: 254 files) X7 X6 X5 X4 X3 X2 X1 X0 Default file X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-13 -

15 8 + 1bit(X8) Binary Mode (Max.: 254 files) X7 X6 X5 X4 X3 X2 X1 X0 Default file X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP Stop playing

16 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file Null MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-15 -

17 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-16 -

18 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-17 -

19 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-18 -

20 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-19 -

21 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-20 -

22 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP3-21 -

23 9 bit Binary Mode (Max.: 510 files) X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file X8 X7 X6 X5 X4 X3 X2 X1 X0 Default file MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP Stop playing

24 Metal Box Dimension

Acceleration/Velocity/Displacement VIBRATION METER

Acceleration/Velocity/Displacement VIBRATION METER Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex

More information

Recording Voice Modules

Recording Voice Modules Recording Voice Modules WTV-SR Manual Data Sheet Table of contents. Features.... Structured flowchart.... Packages diagram... 4. Parameters... 4. Environmental Absolute Max Ratings.... Control modes.....

More information

PAGENET88 ZONE PAGING SYSTEM

PAGENET88 ZONE PAGING SYSTEM SERVIE INFORMTION PGENET ZONE PGING SYSTEM ONTENTS: OPERTION MNUL SHEMTI IGRMS pin WIRING ustralian Monitor lyde Street, Silverwater NSW ustralia + www.australianmonitor.com.au PageNet Zone Paging System

More information

Digital Torque Meter ADT-C Series OPERATION MANUAL

Digital Torque Meter ADT-C Series OPERATION MANUAL ADT-C Series Digital Torque Meter ADT-C Series OPERATION MANUAL CO., LTD Digital Torque Meter It is the torque-measuring instrument of the electronic formula which can measure torque power. It corresponds

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver.   Last Updated 12/14/2004 SC125MS Stepper Motor Driver Salem Controls Inc. Last Updated 12/14/2004! Warning! Stepper motors and drivers use high current and voltages capable of causing severe injury. Do not operate this product

More information

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is

More information

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW GW Professional Weighing Scale User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW 20100415 Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML

More information

Bright Advance Corporation

Bright Advance Corporation USER INSTRUCTIONS TABLE OF CONTENTS INSTRUCTIONS FOR USE2 PREPARING TO USE THE SCALE2 DISPLAYS3 KEYBOARD FUNCTION4 OPERATION7 COUNTING14 DIFFERENT KEYBOARD TYPES21 INTERFACE31 POWER SOURCES40 1 INSTRUCTIONS

More information

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd

CANBUS-THERMO-2CH Rev B v Channel CAN-Bus Thermocouple Interface K-Type. V1.0 July SK Pang Electronics Ltd 2 Channel CAN-Bus Thermocouple Interface K-Type V1.0 July 2016 Product name Model number Manufacturer 2 Channel CAN-Bus Thermocouple Interface K-Type CANBUS-THERMO-2CH SK Pang Electronics Ltd 1 Contents

More information

High Resolution High Sensitivity SDR Super Wide Dynamic Camera

High Resolution High Sensitivity SDR Super Wide Dynamic Camera High Resolution High Sensitivity SDR Super Wide Dynamic Camera INSTRUCTION MANUAL 15-CA45R 15-CA45RC CONTENTS PRECAUTION.2 FEATURES..3 DIMENSION...3 INSTALLATION...4 SPECIFICATIONS..5 BASIC TECHNICAL DATA

More information

Principal and Maintenance of INNOVATION 5.1 SUB

Principal and Maintenance of INNOVATION 5.1 SUB Principal and Maintenance of INNOVATION. SUB. Brief introduction to product INNOVATION. SUB is a medium grade active loudspeaker that comprised of one sub-woofer and two fronts, two surrounds and one center.

More information

Grabber. Technical Manual

Grabber. Technical Manual Grabber 0 MHZ Analog Signal Digitizer Technical Manual 0 th Street, Davis, CA, USA Tel: 0--00 Fax: 0--0 Email: sales@tern.com http://www.tern.com COPYRIGHT Grabber, and A-Engine are trademarks of TERN,

More information

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen

More information

user's manual nx frequency converters resolver option board opt-bc

user's manual nx frequency converters resolver option board opt-bc user's manual nx frequency converters resolver option board opt-bc INDEX Document code: ud01039d Date: 18.2.2011 1. Resolver option board OPT-BC... 3 1.1 Resolver basics... 3 1.2 Resolver board features...

More information

Data Logger V2. Instruction Manual

Data Logger V2. Instruction Manual Data Logger V2 Instruction Manual Joe Holdsworth 7-29-2018 Contents Revision History... 2 Specifications... 3 Power Limits... 3 Data Rates... 3 Other Specifications... 3 Pin Outs... 4 AS218-35SN... 4 AS210-35SN...

More information

Features of Uni-Thermo

Features of Uni-Thermo Long-life. High reliability Uni-Thermo Peltier Device in the 1st Century CONTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality

More information

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card CHV Series Vector Control Inverter Options Operating Instructions for Control Card 1. Model and Specifications 1.1 Model The model of tension card is CHV00ZL. CHV series inverter can conduct constant

More information

T4 TIMER - PROJECT DESCRIPTION - rev. 5.10

T4 TIMER - PROJECT DESCRIPTION - rev. 5.10 1. Display Logic A. When displaying in HH:MM, it will not be obvious from the display that the timer is counting, the 4 dots at the bottom of the display chase from left to right to indicate its counting

More information

P300. Technical Manual I/Os, 240 solenoid drivers th Street, Davis, CA 95616, USA Tel: Fax:

P300. Technical Manual I/Os, 240 solenoid drivers th Street, Davis, CA 95616, USA Tel: Fax: 00+ I/Os, 0 solenoid drivers Technical Manual 0 th Street, Davis, CA, USA Tel: 0--00 Fax: 0--0 Email: sales@tern.com http://www.tern.com COPYRIHT, i-engine, A-Engine, R-Engine and ACTF are trademarks of

More information

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this 3 in 1 VIBRATION TACHOMETER Model : VT-8204 Your purchase of this VIBRATION TACHOMETER marks a step forward for you into the field of precision measurement. Although this VIBRATION TACHOMETER is a complex

More information

station) on the serial port

station) on the serial port Connects a Davis VantagePro2 or Vantage Vue to a BACnet network BACnet MS/TP over RS-485 compatible Easy BACnet network configuration via onboard switches Various selectable metric and imperial unit conversions

More information

AW/AHW Professional Weighing Scale. User Manual

AW/AHW Professional Weighing Scale. User Manual AW/AHW Professional Weighing Scale User Manual Sep. 2009 Table of Contents Specifications... 2 Basic specification... 2 Series specification... 2 Display and keypad... 3 LCD Display... 3 Keypad... 4 Using

More information

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon VELA Getting started with the VELA Versatile Laboratory Aid Paul Vernon Contents Preface... 3 Setting up and using VELA... 4 Introduction... 4 Setting VELA up... 5 Programming VELA... 6 Uses of the Programs...

More information

VIBRATION METER. Instruction Manual.

VIBRATION METER. Instruction Manual. VIBRATION METER 840063 Instruction Manual CONTENTS Title Page I. Introduction... 2 II. Panel Description... 3 III. Operating Instructions A. General Measurement Procedures... 3~4 B. Peak... 5 C. Data Hold...

More information

POINTS OF CAUTION BEFORE USE...

POINTS OF CAUTION BEFORE USE... INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the

More information

89BSD CALCULATION METHOD APPLICATION NOTE

89BSD CALCULATION METHOD APPLICATION NOTE FUNCTIONAL DESCRIPTION GENERAL The 89BSD consists of a piezoresistive sensor and a sensor interface IC. The main function of the sensor interface IC is to convert the uncompensated analogue output voltage

More information

WTR-S4 Module User Manual WTR-S4 MODULE

WTR-S4 Module User Manual WTR-S4 MODULE WTR-S MODULE.PRODUCT FEATURES....FUTION DESCRIPTIONS....RELATIONSHIP OF FLASH MEMORY CAPACITY AND RECORDING DURATION....APPLICATION DIAGRAM....PACKAGE SKETCH MAP....PIN DESCRIPTIONS.... SAMPLING RATE SETTINGS....PARAMETERS...

More information

User Manual. 1000BASE-T1 SFP Module

User Manual. 1000BASE-T1 SFP Module User Manual 1000BAS-1 SFP Module Version 0.4 05. March 2018 echnica ngineering GmbH Fax: +49-89-200-072430 Leopoldstraße 236 mail: Info@technica-engineering.de 80807 München www.technica-engineering.de

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

QUANTUM CONCEPT. Swimming User s Manual

QUANTUM CONCEPT. Swimming User s Manual QUANTUM CONCEPT Swimming User s Manual 480.508.0 Version.4 Edition July 05 Documentation Updates Swiss Timing Ltd. reserves the right to make improvements in the products described in this documentation

More information

MODBUS Protocol for CS141 network card families

MODBUS Protocol for CS141 network card families Last update: 20/09/208 MODBUS Protocol for CS4 network card families Summary. MODBUS PROTOCOL... 2.. MODBUS COMMUNICATION PARAMETERS... 2.2. AVAILABLE MODBUS FUNCTION CODES... 2.3. EXCEPTION CODES... 3

More information

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL CONTENTS 1. BASIC INFORMATION 3 2. USING THE INFORMATION 4 3. THE PROFILE OF THE METER 5 4. TECHNICAL DATA 7 5. SCREENS 8 6. USING THE KEYBOARD 10 7. THE

More information

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows: The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering

More information

P300. Technical Manual

P300. Technical Manual + I/Os, solenoid drivers Technical Manual icasso venue, avis, C, US Tel: -- Fax: -- Email: sales@tern.com http://www.tern.com COYRIHT, i-engine, -Engine, R-Engine and CTF are trademarks of TERN, Inc. mes

More information

Description of the ED library Basic Atoms

Description of the ED library Basic Atoms Description of the ED library Basic Atoms Simulation Software / Description of the ED library BASIC ATOMS Enterprise Dynamics Copyright 2010 Incontrol Simulation Software B.V. All rights reserved Papendorpseweg

More information

PC Control / Touch Control

PC Control / Touch Control PC Control / Touch Control Version 6.0 / 5.840.0150 New Features Manual 8.840.8007EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com

More information

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a

More information

UNISONIC TECHNOLOGIES CO., LTD TDA7269

UNISONIC TECHNOLOGIES CO., LTD TDA7269 UNISONIC TECHNOLOGIES CO., LTD TDA7269 14W+14W STEREO AMPLIFIER WITH MUTE & STAND-BY DESCRIPTION The UTC TDA7269 is a stereo 14+14W class AB Dual Audio Power amplifier with mute and ST-BY control. This

More information

Meteorological Station P03/3-RS485-WAGO

Meteorological Station P03/3-RS485-WAGO Meteorological Station P03/3-RS485-WAGO Technical data and notes for installation Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93 97-0

More information

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131

More information

OPERATING MANUAL. EIB-Kombisensor AS 315 N

OPERATING MANUAL. EIB-Kombisensor AS 315 N EIB-Kombisensor AS 315 N OPERATING MANUAL EIB-Kombisensor AS 315 N 1 Contents Page 3 1. Description 4 1.1 Automated Operations 1.1.1 Sun System 1.1.2 Half-Light System 5 1.1.3 Wind System 1.1.4 Rain System

More information

T1 and E1 Feature Cards

T1 and E1 Feature Cards CHAPTER 3 This chapter provides procedures for installing and removing the T1 and E1 feature cards and includes the following sections: Overview, page 3-1 Online Installation and Removal of the T1 or E1

More information

ISSP User Guide CY3207ISSP. Revision C

ISSP User Guide CY3207ISSP. Revision C CY3207ISSP ISSP User Guide Revision C Cypress Semiconductor 198 Champion Court San Jose, CA 95134-1709 Phone (USA): 800.858.1810 Phone (Intnl): 408.943.2600 http://www.cypress.com Copyrights Copyrights

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

O P E R A T I N G M A N U A L

O P E R A T I N G M A N U A L OPERATING MANUAL WeatherJack OPERATING MANUAL 1-800-645-1061 The baud rate is 2400 ( 8 bits, 1 stop bit, no parity. Flow control = none) To make sure the unit is on line, send an X. the machine will respond

More information

IO-Link Data Reference Guide: K50 Pro Touch Button with IO-Link

IO-Link Data Reference Guide: K50 Pro Touch Button with IO-Link IO-Link Data Reference Guide: K50 Pro Touch Button with IO-Link IO-Link Data Map This document refers to the following IODD file: Banner_Engineering-K50PTKQ-20180829-IODD1.1.xml. The IODD file and support

More information

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59. MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59 Modbus RTU MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide This page is intentionally left blank. SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide The ACTiSys IR Programmer and SuperCELL

More information

OP-02 / OP-03 / OP-04

OP-02 / OP-03 / OP-04 FS-i Series Check Weighing Scales Option OP-02 / OP-03 / OP-04 WM+PD4001368 Contents 1. OP-02 BATTERY... 2 1-1. Using the OP-02 SLA Battery... 2 2. OP-03 RS-232C / RELAY OUTPUT... 4 2-1. Installation...

More information

Operating instructions for electronics

Operating instructions for electronics Operating instructions for electronics Initial startup (m, C, 24h) Menu choice The functions of the Traveller can be checked when the battery is inserted: 1. Segment check Do all segments light up? 2.

More information

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features. Description Characteristic features Industrial temperature measuring method Wide measuring range, -270...+1360 C Digital I²C-interface Simple integration to micro-controller Scope of supply with thermocouple,

More information

Drive electronics pq12

Drive electronics pq12 Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current

More information

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:

More information

Features of Uni-Thermo

Features of Uni-Thermo Pelti ier Device in the 21st Uni-Thermo Century Hi eliability NTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality Chart Peltier

More information

Dual laser + type K thermometer INFRARED THERMOMETER

Dual laser + type K thermometer INFRARED THERMOMETER Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER

More information

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product. Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

PAID INVOICE TAX REPORT

PAID INVOICE TAX REPORT PAID INVOICE TAX REPORT The documentation in this publication is provided pursuant to a Sales and Licensing Contract for the Prophet 21 System entered into by and between Prophet 21 and the Purchaser to

More information

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual Quanser NI-ELVIS Trainer (QNET) Series: QNET Experiment #05: HVAC System Identification Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual Table of Contents 1. Laboratory Objectives...1

More information

VCE VET ELECTROTECHNOLOGY

VCE VET ELECTROTECHNOLOGY Victorian Certificate of Education 2006 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words VCE VET ELECTROTECHNOLOGY Written examination Thursday 2 November 2006 Reading time:

More information

Minimum (-31) every 10 s -35 (-31)

Minimum (-31) every 10 s -35 (-31) Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement

More information

PRIMARE A32 Power Amplifier Service Manual

PRIMARE A32 Power Amplifier Service Manual PRIMRE Power mplifier Service Manual . Technical Description.. Error codes.. Bias djustment.. Schematics.. Technical Specifications. onfidential! This document is not allowed to show for third part without

More information

Series CCR-39S Multi-Throw DC-12 GHz, SP7T & SP8T Latching Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP7T & SP8T Latching Coaxial Switch PART NUMBER CCR-39S DESCRIPTION Commercial Latching Multi-throw, DC-12GHz The CCR-39S is a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input

More information

Display counter electromechanical

Display counter electromechanical Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical

More information

Thermal Parameter Measurement AN 18

Thermal Parameter Measurement AN 18 Thermal Parameter Measurement AN 18 Application Note to the R&D SYSTEM The lumped parameters of the thermal equivalent circuit are measured by using Power Test Module (PWT) The high-speed temperature monitoring

More information

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX LANCER reserves the right to modify, constantly its documentation for its improvement. The values of adjustments indicated in the displays of this manual are

More information

The Challenge is to Define: System Engineering. System Engineering Components. Functional Requirements

The Challenge is to Define: System Engineering. System Engineering Components. Functional Requirements The Challenge is to Define: System Engineering What it is supposed to do How well it must do it It s constituant parts and how they play together We are not prepared for detail design, assembly and test

More information

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System B V alidator ill ill alidator A6&V6 Series Installation Guide 4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System 2003 International Currency

More information

Installation Instructions: ICON Anti-Condensate Controller

Installation Instructions: ICON Anti-Condensate Controller TECHNICAL BULLETIN Installation Instructions: ICON Anti-Condensate Controller System Overview The ICON Anti-Condensate Controller System (pat. pend.) is a stand-alone controller for antisweat heaters in

More information

93L34 8-Bit Addressable Latch

93L34 8-Bit Addressable Latch 93L34 8-Bit Addressable Latch General Description The 93L34 is an 8-bit addressable latch designed for general purpose storage applications in digital systems It is a multifunctional device capable of

More information

Mark Redekopp, All rights reserved. Lecture 1 Slides. Intro Number Systems Logic Functions

Mark Redekopp, All rights reserved. Lecture 1 Slides. Intro Number Systems Logic Functions Lecture Slides Intro Number Systems Logic Functions EE 0 in Context EE 0 EE 20L Logic Design Fundamentals Logic Design, CAD Tools, Lab tools, Project EE 357 EE 457 Computer Architecture Using the logic

More information

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch PART NUMBER CCR-39S DESCRIPTION Commercial Latching Multi-throw, DC-12GHz The CCR-39Sis a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input

More information

Dewpoint Meter Data Sheet / Instructions

Dewpoint Meter Data Sheet / Instructions Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment

More information

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1. Motors Automation Energy Transmission & Distribution Coatings Servo Drive SCA06 V1.5X SCA06 V1.4X Series: SCA06 Language: English Document Number: 10003604017 / 01 Software Version: V1.5X Publication Date:

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department Physics 8.01 Fall Term 2010 Experiment 03: Work and Energy Purpose of the Experiment: In this experiment you allow a cart to roll down an inclined

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact 853 LED beacon is particularly versatile. With an

More information

WeatherLink for Windows

WeatherLink for Windows for Windows 6510SER 6544 6510USB 6550 65556540 6560 Software and Data Logger for Windows for Vantage Stations consists of software and a specialized data logger that connects to a Vantage station or Weather

More information

Using a Microcontroller to Study the Time Distribution of Counts From a Radioactive Source

Using a Microcontroller to Study the Time Distribution of Counts From a Radioactive Source Using a Microcontroller to Study the Time Distribution of Counts From a Radioactive Source Will Johns,Eduardo Luiggi (revised by Julia Velkovska, Michael Clemens September 11, 2007 Abstract In this lab

More information

Non-Acoustical Inputs

Non-Acoustical Inputs CHAPTER 18 Non-Acoustical Inputs This chapter discusses the use of external transducers and devices to provide non-acoustical data to the Model 831. Included are the following: 831-INT 831-INT Interface

More information

E2T0 DVP

E2T0 DVP 29-5-26 5116868-E2T DVP-11363-1 ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 temperature measurement module receives 4 points of external thermocouple temperature sensors (J-type, K-type,

More information

Circular Motion and Centripetal Force

Circular Motion and Centripetal Force [For International Campus Lab ONLY] Objective Measure the centripetal force with the radius, mass, and speed of a particle in uniform circular motion. Theory ----------------------------- Reference --------------------------

More information

Data Sheet / Instructions. Dewpoint MeterO

Data Sheet / Instructions. Dewpoint MeterO Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.

More information

WEIGHT INDICATOR WIDRA W90

WEIGHT INDICATOR WIDRA W90 WEIGHT INDICATOR WIDRA W90 Function keys WIDRA SPRL Rue Z Gramme, 26 Zoning «Les Plennesses «4821 ANDRIMONT M when this key is pressed, the display registers "0", which frees one of the stored entry weights

More information

PAST EXAM PAPER & MEMO N3 ABOUT THE QUESTION PAPERS:

PAST EXAM PAPER & MEMO N3 ABOUT THE QUESTION PAPERS: EKURHULENI TECH COLLEGE. No. 3 Mogale Square, Krugersdorp. Website: www. ekurhulenitech.co.za Email: info@ekurhulenitech.co.za TEL: 011 040 7343 CELL: 073 770 3028/060 715 4529 PAST EXAM PAPER & MEMO N3

More information

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch COAX SWITCHES Series CCR-39S PART NUMBER CCR-39S DESCRIPTION Commercial Latching Multi-throw, DC-12GHz The CCR-39Sis a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave

More information

Mitsubishi Q00/Q00UJ/Q01/QJ71

Mitsubishi Q00/Q00UJ/Q01/QJ71 Connection Guide Mitsubishi Q00/Q00UJ/Q01/QJ71 Supported Series: Mitsubishi Q series with QJ71C24 communication module, Q00, Q00J, Q00UJ, Q01, Q02H, Q06H, Q12H, Q25H, Q12PH, Q25PH CPU port. Website: http://www.mitsubishi-automation.com

More information

Inbuilt Modbus Protocol

Inbuilt Modbus Protocol Inbuilt Modbus Protocol Technical description Revision 1.1 Page 1 1. Revisions History... 3 2. Preface... 3 2.1. Overview... 3 2.2. Default settings... 3 3. Modbus commands... 3 3.1. Read holding registers

More information

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5. HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation

More information

VISY-Quick Communication Protocol

VISY-Quick Communication Protocol VISY-Quick Communication Protocol Rev. Protocol Version Modification VI Version Date Name 0 1.00 First release 2.0.1 2000-03-29 Willmer 1 1.10 New commands date and time (3.2... 3.5) 2.0.2 2000-07-07 Willmer

More information

TitriSoft 2.5. Content

TitriSoft 2.5. Content Content TitriSoft 2.5... 1 Content... 2 General Remarks... 3 Requirements of TitriSoft 2.5... 4 Installation... 5 General Strategy... 7 Hardware Center... 10 Method Center... 13 Titration Center... 28

More information

AN6783S. IC for long interval timer. ICs for Timer. Overview. Features. Applications. Block Diagram

AN6783S. IC for long interval timer. ICs for Timer. Overview. Features. Applications. Block Diagram IC for long interval timer Overview The is an IC designed for a long interval timer. It is oscillated by using the external resistor and capacitor, and the oscillation frequency divided by a - stage F.F.

More information

User s Manual. Surface Potential Meter. Revision 1.0

User s Manual. Surface Potential Meter. Revision 1.0 User s Manual Surface Potential Meter Revision 1.0 1. INTRODUCTION 3 2. TECHNICAL SPECIFICATIONS 4 3. GENERAL INTRODUCTION 5 4. PRINCIPLE OF MEASUREMENT 6 5. INSTALLING THE 7 5.1. Installation steps 7

More information

PiCUS Calliper Version 3

PiCUS Calliper Version 3 Technology PiCUS Calliper Version 3 Digital calliper for precise geometry detection argus electronic GmbH Erich-Schlesinger-Straße 49d 18059 Rostock Germany Tel.: +49 (0) 381/49 68 14 40 www.argus-electronic.de

More information

Humidity, and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-2-LCD BAT 3V6 1/2AA FEATURES 0 to 100 measurement

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program 4140 + 8 + 0 + 0 (Display should show 00, also try 4130 and 5130) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by

More information