Calibration, traceability, uncertainty and comparing measurement results. Workshop 16 March 2015 VSL, Delft The Netherlands
|
|
- Hector Sanders
- 5 years ago
- Views:
Transcription
1 Calibration, traceability, uncertainty and comparing measurement results Workshop 16 March 2015 VSL, Delft The Netherlands 1
2 Calibration Calibrating an instrument involves comparing the measurements of two instruments; one with a known magnitude or correctness (standard/reference device - REF), against which you measure the device under test (DUT) REF 2
3 Calibration Calibration is required for: Testing a new measurement instrument Testing a measurement instrument after it has been repaired or modified Periodic testing of measurement instruments Testing after the specific usage has elapsed Prior to and/or after a critical measurement When observations are not accurate or instrument indicators do not match the output of a surrogate measurement instrument After events such as: An measurement instrument has had a shock, vibration, or exposure to adverse conditions, which can put it out of calibration or damage it. 3
4 Calibration Risks involved in not calibrating an instrument Safety procedure Wastage Faulty or questionable quality Fines or litigations Increased downtime 4
5 Calibration Calibration frequency Manufacturer-recommended calibration interval. Before a major critical measuring project. After a major critical measuring project. After an event (error, damage, shocks) Per requirements. Monthly, quarterly, or semiannually. Annually. Biannually. Never. 5
6 Metrological Traceability property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty BIPM Paris Traceability Process industry, Aviation, Meteorology, Pharmacy, Science 6
7 Metrological Traceability 7
8 Metrological Traceability Certificate Primary Pressure Standard 0,003 % National Metrology Institute (NMI) Process Certificate 0,2 % Calibration Validation 0,05 % 0,01 % Certificate Accredited Calibration Laboratory Traceability from Industry to a NMI Certificate
9 Metrological Traceability weights Piston cylinder unit time Pressure medium mass length
10 Metrological Traceability BIPM Paris Grand K (BIPM) 1 kg 0 mg PtIr (NMI) 1 kg 0,010 mg Reference standards (NMI) 1 kg 0,026 mg Working standards (NMI) 1 kg 0,150 mg (E1) Mass standards (Accr. laboratories) 1 kg 0,50 mg (E2) Mass standards/scales (Industry) 1 kg 1,50 mg t/m 500 mg (F1 M3) 10
11 Measurement Uncertainty U = 1 mm U = 0, mm
12 Measurement Uncertainty U = 0,02 bar U = 0,0002 bar
13 Measurement Uncertainty U = 0,1 kg U = 0, kg
14 Measurement Uncertainty U = 1 C U = 0,0001 C
15 Measurement Uncertainty U = 2 L U = 0,0025 L
16 Measurement Uncertainty Type A evaluation Several (in)dependent observations Observable scatter in the values obtained Statistical methods Type B evaluation Calibration of the reference standard Ambient conditions Calibration method Calibration/test engineer 16
17 Measurement Uncertainty 17
18 Measurement Uncertainty 18
19 Measurement Uncertainty 19
20 Interlaboratory Comparisons Competenc e personnel Participation ILC s and PTS Approved Test and Calibration Methods Improvement of Quality Test and Calibration Results 20
21 Interlaboratory Comparisons NMI Regional NORAMET comparison NMI BIPM NMI Global CIPM comparison NMI NMI NMI NMI NMI NMI EA lab RvA lab lab RvA lab National comparison or PTS NMI VSL, Delft NMI lab NMI Regional EURAMET/COOMET/AFRIMET comparison National comparison RvA lab NMI EA lab EA lab EA lab lab Regional EA comparison EA lab 21
22 Lref L001 L002 L003 L004 L005 L006 L007 L008 L009 L010 L011 L012 L013 L014 L015 L016 L017 Deviations Lref - participants /kpa Interlaboratory Comparisons Agreement Lref - participants at kpa g 70,0 60,0 50,0 40,0 30,0 20,0 22
23 Nominal pressure Deviation Uncertainty Deviation Uncertainty Deviation Uncertainty Deviation Uncertainty Deviation Uncertainty Lref L013 L014 L015 L016 Interlaboratory Comparisons Lab Normalized Error E N kpa kpa kpa kpa kpa 0 0 1,3 0,0 0,7 0,00 0,0 3,0 0,00 0,0 3,0 0,00 0,0 0,0 0, ,0-7,0 1,7 1,56-6,5 4,2 0,99-11,0 5,0 0,02-7,7 5,0 0, ,1-4,5 2,7 1,38-6,0 6,3 0,60-13,0 6,0-0,41-6,6 7,2 0, ,0 5,0 3,7 1,16 3,5 8,0 0,54-6,0 6,0-0,65 3,7 9,4 0, ,0 19,5 4,7 0,94 18,0 10,0 0,44 6,0 8,0-0,75 18,4 11,6 0, ,3 35,5 5,7 0,71 35,5 13,0 0,41 22,0 10,0-0,64 35,5 13,7 0, ,6 53,5 6,7 0,60 54,0 15,0 0,39 40,0 11,0-0,56 53,0 15,9 0, ,7 72,0 18,0 0,31 58,0 13,0-0,49 69,9 18,1 0,21 Normalized Error E N Normalized Error E N Normalized Error E N 23
24 ISO/IEC 17025:2005 Key-issues: Competence staff Calibration/testing method Equipment and/or instruments Uncertainty calculation Traceability Ambient condition and facilities Interlaboratory comparisons and Proficiency Testing Uncertainty Tracebility Competence personnel Participation ILC s and PTS Approved Test and Calibration Methods 24 Quality Test and Calibration Results
25 ISO/IEC 17025:
26 Thank you for your attention! Any Questions? 26
NEW VSL Conditioning plate!
Calibration of Prover Tanks using a Coriolis Mass Flow Meter as the Master Meter. Is this possible for Pipe Prover calibration too? Erik Smits (fsmits@vsl.nl) 2 nd European Flow Measurement Workshop Sintra,
More informationRECENT ILC ACTIVITY IN ROMANIAN MASS MEASUREMENTS
The Fifth International Proficiency Testing Conference Timisoara, Romania () th 8 th September, 0 RECENT ILC ACTIVITY IN ROMANIAN MASS MEASUREMENTS Adriana Vâlcu, Sterică Baicu National Institute of Metrology,
More informationMetrology and Environment
Bridging the Gap Responding to Environmental Change: from Words to Deeds 14-16 May 2008, Portorož Metrology and Environment Prof Janko Drnovšek and Laboratory group Janko.Drnovsek@fe.uni-lj.si Basic dilemma
More informationTechnical Protocol of the CIPM Key Comparison CCAUV.V-K5
Technical Protocol of the CIPM Key Comparison CCAUV.V-K5 2017-03-06 revised 2018-02-13 (changed schedule) Task and Purpose of the Comparison According to the rules set up by the CIPM MRA the consultative
More informationDocument No: TR 12 Issue No: 1
ESTIMATION OF THE UNCERTAINTY OF MEASUREMENT BY CALIBRATION LABORATORIES AND SPECIFICATION OF CALIBRATION AND MEASUREMENT CAPABILITY ON SCHEDULES OF ACCREDITATION Prepared by: SADCAS Technical Manage Approved
More informationMETHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone
METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT Scott Crone North American Sales Manager AMETEK Calibration Instruments 8600 Somerset Drive Largo, Florida 33773 USA INTRODUCTION Like any other piece of equipment,
More informationCALIBRATION REPORT FOR THERMOHYDROMETER
CALIBRATION REPORT FOR THERMOHYDROMETER SAMPLE CUSTOMER S/N: XXXXX Report Number: Y205188 Page 1 of 5 Report No. Y205188 ICL CALIBRATION LABORATORIES, INC. ISO/IEC 17025 and ANSI/NCSL Z540-1 accredited
More informationOA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents
UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC 17025 Table of contents 1 GENERAL... 2 2 THE STANDARD SIST EN ISO/IEC 17025... 2 3 SA'S POLICY IN IMPLEMENTING
More informationSWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant
SWGDRUG GLOSSARY These definitions were developed and adopted by the SWGDRUG Core Committee from a variety of sources including The United Nations Glossary of Terms for Quality Assurance and Good Laboratory
More informationTechnical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1
Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1 Updated at 12-December-2012 Task and Purpose of the Comparison According to the rules set up by the CIPM
More informationDemonstrating Competency and Equivalency of Two Commercial SPRT Calibration Facilities
Demonstrating Competency and Equivalency of Two Commercial SPRT Calibration Facilities T. J. Wiandt 1,2 1 Fluke Corporation, Hart Scientific Division, American Fork, Utah United States. 2 E-mail: tom.wiandt@hartscientific.com
More informationMeasurement & Uncertainty - Basic concept and its application
Measurement & Uncertainty - Basic concept and its application Feb. 7. 2012 JongOh CHOI (choijongoh@kriss.re.kr) Knowledge and measurement When you can measure what you are speaking about, and express it
More informationSTATISTIQUE DE PERFORMANCE
INTERCOMPARISON OF STANDARD CALIBRATION, METHODS AND MEASUREMENTS FOR PRESSURE, TEMPERATURE AND HUMIDITY BETWEEN RIC CASABLANCA, MOROCCO AND RIC Ljubljana SLOVENIA 3(10) azizmounir@gmail.com The operators
More informationR SANAS Page 1 of 7
ESTIMATION OF THE UNCERTAINTY OF MEASUREMENT BY CALIBRATION LABORATORIES AND SPECIFICATION OF CALIBRATION AND MEASUREMENT CAPABILITY ON SCHEDULES OF ACCREDITATION Approved By: Chief Executive Officer:
More informationA61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012
Revision 1.2 October 15, 2012 PAGE II TABLE OF CONTENTS TABLE OF CONTENTS... 1 GUIDANCE...2 1.0 Introduction... 2 2.0 Uncertainty and Traceability... 2 3.0 Need for Traceability... 3 3.1 What does traceability
More informationFinal Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR
Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR Jin Wan Chung 1, Shih Mean Lee, Sungjun Lee 1 1 Korea Research Institute of Standards
More informationCERTIFICATE OF CALIBRATION
Page 1 of 10 CALIBRATION OF Sound Level Meter: Brüel & Kjær Type 3050-A-040 No: 3050-100751 Id: - Microphone: Brüel & Kjær Type 4189 No: 2621142 Preamplifier: Brüel & Kjær Type 2669 No: 2679073 Supplied
More informationMeasurement & Uncertainty - Concept and its application
Measurement & Uncertainty - Concept and its application June. 20 2012 JongOh Choi (choijongoh@kriss.re.kr) I don t know what I don t know. If we don t express what we know in the form of numbers, we really
More informationTechnical Procedure for Measurement Assurance
Technical Procedure for Measurement Assurance 1.0 Purpose - This procedure specifies the required elements for measurement assurance in the Drug Chemistry Sections of the State Crime Laboratory. 2.0 Scope
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ALLOMETRICS, INC. 2500 Bayport Blvd. Seabrook, TX 77586 Terry Baldwin Phone: 281 474 3329 CALIBRATION Valid To: April 30, 2019 Certificate Number: 2039.01 In
More informationReference Materials and Proficiency Testing. CropLife International Meeting October 2015 Gina M. Clapper
Reference Materials and Proficiency Testing CropLife International Meeting 15-16 October 2015 Gina M. Clapper Approaches to Improving and Demonstrating Method and Laboratory Performance Analytical quality
More informationSPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Torque Measuring Devices
NABL 122-10 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Torque Measuring Devices Reviewed by MASTER COPY
More informationFinal Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede
Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS Jan P.M. de Vreede Department of Electricity, Radiation and Length NMi Van Swinden Laboratorium Thijsseweg 11, 2629 JA Delft, the
More informationEstablishment of a Traceability Chain in Metrology for Materials
Establishment of a Traceability Chain in Metrology for Materials G. W. Bahng*, Colin Lea** *KRISS, gwbahng@kriss.re.kr, **NPL, cl@npl.co.uk Abstract Materials metrology is becoming an increasingly important
More informationMason Technology Ltd
Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule
More informationMulti Analyte Custom Grade Solution. Calcium, Iron, Potassium,
1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Laboratory locations: Schedule of Accreditation 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 1G Kilroot Business Park Carrickfergus Co Antrim BT38 7PR Contact: Mr R E Hughes Tel:
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationANALYSIS CERTIFICATE OF
CERTIFICATE OF ANALYSIS 300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 INORGANIC VENTURES is an
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationEstablishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements
Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements Experimental Design 8.2.2013 Doc. Martti Heinonen etunimi.sukunimi@mikes.fi Outline 1.
More informationEuramet project 1075 Bilateral comparison
Bilateral comparison Between the gas flow standards of the national Metrology Institutes of Bulgaria (BIM-NCM) and The Netherlands (VSL) Copyright VSL B.V. Dutch Metrology Institute Page 2 of 19 VSL Thijsseweg
More informationMulti Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE
1.0 ACCREDITATION / REGISTRATION INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for
More informationANNEXE 8. Technical protocols for the interlaboratory comparisons
ANNEXE 8 Technical protocols for the interlaboratory comparisons TECHNICAL PROTOCOL FOR BILATERAL COMPARISON (Magnitude of the complex charge sensitivity of accelerometers) EURAMET.AUV.V-S1 1. INTRODUCTION
More informationInfrared Thermometer Calibration A Complete Guide
Infrared Thermometer Calibration A Complete Guide Application note With proper setup and planning, infrared calibrations can be accurate. The steps outlined below should be followed to perform accurate
More informationMetrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017
Metrology Principles for Earth Observation: the NMI view Emma Woolliams 17 th October 2017 Interoperability Decadal Stability Radiometric Accuracy Identical worldwide Century-long stability Absolute accuracy
More informationHOW TO EXPRESS THE RELIABILITY OF MEASUREMENT RESULTS. The role of metrological traceability and measurement uncertainty-
HOW TO EXPRESS THE RELIABILITY OF MEASUREMENT RESULTS The role of metrological traceability and measurement - H. Imai 1 1 National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial
More informationMason Technology Ltd
Mason Technology Ltd 228 South Circular Road, Dublin 8 Calibration Laboratory Registration number: 043C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule
More informationSPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments
NABL 122-06 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Force Proving Instruments Reviewed by MASTER
More informationEA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Publication Reference EA-10/11 EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical PURPOSE This document has been produced by EA as a means of giving advice for calibrating
More informationMorehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:
Morehouse 1 Morehouse Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com sales: edlane@mhforce.com 2 This presentation will cover the calibration
More informationFinal Results of Bilateral Comparison between NIST and PTB for Flows of High Pressure Natural Gas
Final Results of Bilateral Comparison between NIST and for Flows of High Pressure Natural Gas B. Mickan (, Germany, Bodo.Mickan@ptb.de) H. Toebben (pigsar TM, Germany) A. Johnson (NIST,USA, Aaron.Johnnson@nist.gov)
More informationHigh pressure comparison among seven European national laboratories
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. High pressure comparison among seven European national
More informationFinal Report CCEM.RF-K8.CL COMPARISON CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede
Final Report CCEM.RF-K8.CL COMPARISON CALIBRATION FACTOR OF THERMISTOR MOUNTS Jan P.M. de Vreede Department of Electricity, Radiation and Length NMi Van Swinden Laboratorium Thijsseweg 11, 2629 JA Delft,
More informationIntroduction of RIC Tsukuba (Japan, RAII)
Introduction of RIC Tsukuba (Japan, RAII) 20 March, 2018 Kouichi NAKASHIMA Scientific Officer Regional Instrument Centre Tsukuba Observing Division, Observing Department Outline 1. Overview of Organization
More informationMEASUREMENT UNCERTAINTY PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE OCTOBER/NOVEMBER Prepared by MJ Mc Nerney for ENAO Assessor Calibration
MEASUREMENT PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE UNCERTAINTY OCTOBER/NOVEMBER 2012 Prepared by for ENAO Assessor Calibration B SCOPE Introduction House Rules Overview 17025 & 15189 MU Approaches
More informationQuality assurance for sensors at the Deutscher Wetterdienst (DWD)
Quality assurance for sensors at the Deutscher Wetterdienst (DWD) Quality assurance / maintenance / calibration Holger Dörschel, Dr Tilman Holfelder WMO International Conference on Automatic Weather Stations
More informationIntroduction. Martin J. T. Milton. Director of the BIPM. Monday 27th June 2016
Introduction Martin J. T. Milton Director of the BIPM Monday 27th June 2016 Bureau International des Poids et Mesures Established in 1875 by the Metre Convention Based in Paris and financed by 57 Member
More informationCALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014
Calibration General Principles & Theory, Equipment Considerations Metrological Principles Accurate but not Precise Calibration A A+ Correction = Precise but not Accurate Correction B Ref Std (Radio Link
More informationOIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air
INTERNATIONAL DOCUMENT OIML D 28 Edition 2004 (E) Conventional value of the result of weighing in air Valeur conventionnelle du résultat des pesées dans l'air OIML D 28 Edition 2004 (E) ORGANISATION INTERNATIONALE
More informationThe Fundamentals of Moisture Calibration
The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity
More informationAPPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT
APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT Table of Contents 1. SCOPE... 2 2. REFERENCES... 2 3. TERMS AND DEFINITIONS... 2 4. BACKGROUND... 4 5. ESTIMATION OF UNCERTAINTY OF MEASUREMENT POLICY...
More informationComparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576
NPL REPORT CMAM 73 Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576 Peter Hanes October 2001 The National Physical Laboratory is operated on behalf
More informationInterlaboratory Comparison & Proficiency Testing Program
Extended scope for the organization of proficiency tests in accordance with the requirements of ISO/IEC 17043 VSL, the Dutch Metrology Institute, has significantly extended the scope for their accreditation
More informationTRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS
TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS W. Beyer and W. Pahl Physikalisch-Technische Bundesanstalt (PTB) 38116 Braunschweig, Germany Abstract: In accordance with ISO 17025,
More informationTest report CVN Project number Page 2 of 2
Project number 604545 Page 2 of 2 Tests : Results : The diaphragm gas meters as specified in annex 2 were tested for compliance with the European Standard BS EN 1359 : 1999 "Gas meters - Diaphragm gas
More informationA comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs
IMEKO 20 th TC3, 3 rd TC16 and 1 st TC22 International Conference Cultivating metrological knowledge 27 th to 30 th November, 2007. Merida, Mexico. A comparison of primary platinum-iridium kilogram mass
More informationHigh pressure comparisons between seven European National Laboratories
J4/2007 High pressure comparisons between seven European National Laboratories Range 50 MPa to 500 MPa Report on EUROMET Project 881 Markku Rantanen, Sari Semenoja, Måns Ackerholm, Antoine Condereys, Zdenek
More informationComparability and Traceability Point of view from a metrological institute
Comparability and Traceability Point of view from a metrological institute Ed W.B. de Leer NMi Van Swinden Laboratory Delft, The Netherlands 1 My Discussions in Metrologyland 2 The CCQM in 1996 3 Traceability
More informationH1: Metrological support. Milena Horvat, Polona Vreča, Tea Zuliani, Radojko Jaćimović, Radmila Milačič
H1: Metrological support Milena Horvat, Polona Vreča, Tea Zuliani, Radojko Jaćimović, Radmila Milačič Basic requirement How to ensure appropriate measurements and monitor changes in time and space? Analytical
More informationFlowchart for the extraordinary calibrations prior to the redefinition of the kilogram. (BIPM proposal)
Flowchart for the extraordinary calibrations prior to the redefinition of the kilogram (BIPM proposal) Pauline Barat Michael Stock Alain Picard Richard Davis 1 CIPM informed of intention to use IPK Document
More informationCALIBRATION CERTIFICATE # 503
CALIBRATION CERTIFICATE # 503 Calibration date : 2011-02-23 Certificate issued : 2012-04-18 Company name Company address City, Province, Canada CLAS 2009-02 Calibration of Mass flow meter Micro Motion
More informationCalibration Traceability Guidelines
Calibration Traceability Guidelines Check the website of accrediting bodies for the accredited laboratories individual scope of accreditation www.a2la.org ts.nist.gov/standards/accreditation/index.cfm
More informationMEASUREMENT TRACEABILITY AND ERRORS RELATED TO FORCE MEASUREMENT
MEASUREMENT TRACEABILITY AND ERRORS RELATED TO FORCE MEASUREMENT Henry Zumbrun II, President Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com info: hzumbrun@mhforce.com
More informationQuality assurance for sensors at the Deutscher Wetterdienst (DWD)
Paper submitted to ICAWS 2017: Topic 3 Sustainability of the measurements: Calibration, intercomparisons, laboratory and field performance tests, quality assurance and control assessment for traceable
More informationMICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations
Calibration General Principles & Theory, Equipment Considerations Metrological Principles Accurate but not Precise Calibration A A+ Correction = Precise but not Accurate Correction B Ref Std (Radio Link
More informationOn the redefinition of the kilogram. Dr Philippe RICHARD
On the redefinition of the kilogram Dr Philippe RICHARD Agenda 1. Recent history of IPK and new SI 2. The CCM conditions 3. The joint CCM and CCU roadmap 4. The mise en pratique of the definition of the
More informationNew Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018
New Thermometer Guidance Document from AASHTO Accreditation Program Maria Knake Asphalt Binder ETG Meeting May 10, 2018 Background Mercury reduction initiatives have hastened the need to find suitable
More informationSIM FORCE STANDARDS COMPARISON UP TO 10 kn
SIM FORCE STANDARDS COMPARISON UP TO 10 kn Jorge C. Torres-Guzmán, Daniel A. Ramírez-Ahedo Centro Nacional de Metrología, CENAM.. ABSTRACT A comparison in the quantity of force was carried out among the
More informationDedicated solvents for Headspace GC
Dedicated solvents for Headspace GC Dr. Frank Michel sigma-aldrich.com sigma-aldrich.com/analytical Headspace GC - Basics Analysis of headspace above an (aqueous) sample: Gas and vapors are analyzed Injection
More informationISO/IEC requirements. General matters of quality system, requirements for documentation and the list of the documents required for a
ISO/IEC 17025-2006 requirements. General matters of quality system, requirements for documentation and the list of the documents required for a quality system package: quality policy, quality manual, quality
More informationInternational Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories
International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED
More informationEuramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)
Euramet project 87 Comparison of Instrument Current Transformers up to 0 ka Technical protocol (March 0). Introduction AC current ratio is one of two basic parameters in the area of metrology of instrument
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: AMC LABS S.A de C.V (Hereinafter called the Organization)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLORIDA METROLOGY, LLC 645 NW Enterprise Dr. Port St. Lucie FL 34986 Ron Kupper Phone: (772)212-7158 CALIBRATION Valid To: October 31,
More informationLow gauge pressure comparisons between MIKES, Metrosert and FORCE Technology
J2/2007 Low gauge pressure comparisons between MIKES, Metrosert and FORCE Technology Range -2000 to +2000, gauge Report on EUROMET Project 921 Markku Rantanen, Sari Semenoja, Guliko Peterson and Jesper
More informationAPPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY
APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY Table of Contents 1. SCOPE... 2 2. REFERENCES... 2 3. TERMS AND DEFINITIONS... 2 4. BACKGROUND... 4 5. EVALUATION OF MEASUREMENT UNCERTAINTY POLICY... 5
More informationCCM short note on the dissemination process after the proposed redefinition of the kilogram
CCM short note on the dissemination process after the proposed redefinition of the kilogram Consultative Committee for Mass and Related Quantities 1. Introduction This note proposes how the mise en pratique
More informationEA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE
Publication Reference EA-10/14 EA Guidelines on the Calibration of Static Torque Measuring Devices PURPOSE This document has been produced by EA to improve harmonisation in determining the calibration
More informationVocabulary of Metrology
Vocabulary of Metrology For Understating Uncertainty and Traceability Prepared by: Kim, Sang Ho Engineering Team Leader Modal Shop, Inc A PCB Group Company SI National Metrology Institute Secondary Calibration
More informationJoint Research Centre (JRC)
Eurachem 7 th Workshop, Istambul 2011 1 Joint Research Centre (JRC) Brominated Flame Retardants in Plastic A Proficiency Test F. Cordeiro, P. Robouch, B. de la Calle IRMM - Institute for Reference Materials
More informationLINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg. Luis O. Becerra CENAM Querétaro, Qro., Mexico,
LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg Luis O. Becerra CENAM Querétaro, Qro., Mexico, lbecerra@cenam.mx Abstract. Within the frame of SIM (Sistema Interamericano de Metrología), inter laboratory
More informationNIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES
NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM 83.8058 K TO 1234.93 K: METHODS AND UNCERTAINTIES Gregory F. Strouse National Institute of Standards and Technology, Gaithersburg, Maryland, USA ABSTRACT
More informationTRACEABILITY AND CAPABILITY CONTROL OF MASS MEASUREMENT EQUIPMENT AND DRIFT STATISTICAL ANALYSIS OF NATIONAL MASS STANDARDS IN LATVIA
Traceability and capability control of mass measurement equipment and drift statistical analysis of national mass in atvia TRACEABIITY AND CAPABIITY CONTRO OF MA MEAUREMENT EQUIPMENT AND DRIFT TATITICA
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200508-0 Insco Metrology, Inc. Miami, FL is accredited
More informationINTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR
INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR M. Araya 1, D. Almeida 2 1 National Laboratory of Temperature of Chile, LCPNT, Santiago, Chile 2 Ecuadorian Standardization
More informationWGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty
WGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty October 21, 2013 Summary The Working Group for Fluid Flow (WGFF) defines Calibration and Measurement Capability (CMC) uncertainty
More informationSAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0
076-0-067-ACC-USL-S Mettler Toledo, LLC 900 Polaris Parkway Columbus, OH 0.800.METTLER Customer Accredited by the American Association for Laboratory Accreditation (ALA) CALIBRATION CERT #788.0 SAMPLE
More informationTechnical Note A Quantification and NIST Traceability of Micromatter Thin Film Standards for XRF Analysis. Version March 16, 2017
MICROMATTER TECHNOLOGIES INC. #1-8333 130 th Street, Surrey, B.C. V3W 7X4, Canada Phone: +1.604.594.9720 or 1.866.966.2286 Fax: +1.604.594.9726 info@micromatter.com www.micromatter.com Technical Note 2015-01A
More informationReport on EURAMET.M.M-S9
FINAL REPORT Report on EURAMET.M.M-S9 Supplementary comparison of 500 microgram, 200 microgram, 100 microgram and 50 microgram weights (EURAMET project number 1310) Stuart DAVIDSON 1, Adriana VALCU 2,
More informationThe Journey from Ω Through 19 Orders of Magnitude
The Journey from 12 906.403 5 Ω Through 19 Orders of Magnitude Presented at: 2013 NCSLI Conference and Symposium Nashville, Tennessee Personalize with title, slogan or I/B/P name in master slide Kai Wendler
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALABAMA SCALE & INSTRUMENT MARSHALL, INC. d.b.a. ASI Calibration Labs - Texas 1006 East End Blvd North Marshall, TX 75672 Lawson Hill
More informationAnalysis of interlaboratory comparison when the measurements are not normally distributed
Analysis of interlaboratory comparison when the measurements are not normally distributed Alexandre Allard 1,*, Soraya Amarouche 1* 1 Laboratoire National de métrologie et d Essais, 1 rue Gaston Boissier
More informationMeasurement and Calibration of a High-Sensitivity Microwave Power Sensor with an Attenuator
RADIOENGINEERING, VOL. 3, NO. 4, DECEMBER 014 1055 Measurement and Calibration of a High-Sensitivity Microwave Power Sensor with an Attenuator Yu Song MENG, Yueyan SHAN National Metrology Centre, Agency
More informationProgress in organizing national and international comparisons for nuclear medicine measurements
Progress in organizing national and international comparisons for nuclear medicine measurements Maria Sahagia*, Anamaria Cristina Wätjen and Constantin Ivan Horia Hulubei National Institute of Research
More informationMaha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C
629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin Calibration Laboratory Registration number: 287C is accredited by the Irish National Board (INAB) to undertake calibration as detailed
More informationCERTIFICATE OF CALIBRATION
Page 1 of 5 CERTIFICATE OF CALIBRATION 1K Thermistor CERTIFICATE NO.: MANUFACTURER: Measurement Specialties DATE OF CALIBRATION: 26-Apr-17 TC15249 CUSTOMER: AMBIENT TEMPERATURE: (21 ± 3) C JOB NUMBER:
More informationCalibration of Temperature Block Calibrators
European Association of National Metrology Institutes Calibration of Temperature Block Calibrators EURAMET cg-13 Version 2.0 (03/2011) Previously EA-10/13 Calibration Guide EURAMET cg-13 Version 2.0 (03/2011)
More informationHp(0.07) Photon and Beta Irradiations for the EURADOS Extremity Dosemeter Intercomparison 2015
Hp(0.07) Photon and Beta Irradiations for the EURADOS Extremity Dosemeter Intercomparison 2015 Leon de Prez and Frans Bader VSL - The Netherlands www.vsl.nl P 1 Contents - Introduction to VSL and Ionizing
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Compania Nacional de Metrologia S.A.S - Conamet
More information