Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Size: px
Start display at page:

Download "Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward"

Transcription

1 Chemical Analysis PIONA+ Analyzer Characterization of Engine Fuels by Hydrocarbon Group Type think forward Gas Chromatography

2 Bruker 450 PIONA+ Analyzer Bruker s innovative PIONA+ TM Analyzer provides a highly flexible GC analysis platform to obtain comprehensive characterization and quantitative information, including hydrocarbon group types, saturated and unsaturated paraffins and naphthenes, aromatics and oxygenates per carbon number for spark emission fuels. Unparalleled operational flexibility. The inherent flexibility of the analyzer s design allows the operator to conduct analyses in any one of a number of different operational modes including PNA, PONA, PIONA, O-PONA and O-PIONA. Compliant with industry standard methods. Due to the outstanding operational flexibility of the analyzer, it can be utilized for any of the following established standard methods: ASTM D6839, ASTM EN-ISO-22854, ASTM D5443, ASTM D1319, IP-382, IP-526, EN 14157, UOP 870 and DIN A complete and fully integrated solution. Bruker s PIONA+ TM Analyzer is based on the powerful 450-GC gas chromatograph and comes complete with ultra high performance columns and traps, Galaxie chromatography data handling software, dedicated PIONA+ data analysis and report generation software, factory test/certification, calibration/reference standards, PIONA+ manual and on-site installation/performance verification. A single vendor solution. All of Bruker s GC analyzers are built and tested at our factory using all Bruker components. On-site installation and performance verification is then performed by Bruker trained and certified engineers. A powerful analyzer yet very easy to use. Bruker s high performance 450-GC, ultrastable columns and traps and powerful Galaxie data system with built-in PIONA+ software all contribute to the analyzer s ability to generate outstanding analysis results day after day. However, a powerful system does not necessarily have to mean that only highly skilled operators are able to use it. Figure 1: The Bruker PIONA+ TM Analyzer is based on the powerful 450-GC with Galaxie Data System.

3 Key Benefits PIONA is the preferred technique today to characterize petroleum streams by hydrocarbon group type. The technique is based on the separation of individual hydrocarbon groups by utilizing a complex yet fully automated multi-dimensional gas chromatography approach. Analysis challenge Since the first description of PNA (hydrocarbon type) group analysis in the 1980s, the multi-dimensional gas chromatography based technique has gone through continuous improvement and change. Although the technique has evolved and is now commonly used to obtain hydrocarbon group-type information for paraffins, iso-paraffins, naphthenes, olefins, aromatics and oxygenated components (see Tables 1a & 1b) by refinery laboratories worldwide, the basic chromatographic selectivity required to do so has remained fundamentally unchanged. From a gas chromatography hardware standpoint, several different approaches have been used in the past, but the exchange of columns and traps within the multi-dimensional system has always been the most problematic aspect of the analysis. Recent developments in thermal management techniques and mechanical interconnection devices by Bruker have enabled the development of a new class of hydrocarbon group analyzer based on the 450-GC (see Figure 1). The analyzer is not only fully capable of performing a complete analysis as described in ASTM D6839 (and similar methods) but provides unprecedented analysis flexibility and simplified operation through the use of a novel approach to column/trap heating and exchange (see Figure 2). Figure 2: Traps are easily accessible and do not require any tools to install or replace. Table 1a: Example of a Mass% Report. Carbon Number Group Paraffins Cyclic Total BP>185 C 1.01 Oxygenates O-content MTBE Tot. Oxygen 1.32 Table 1b: Example of Volume% Report. Carbon Number Group Paraffins Cyclic Naphthenes Aromatics Naphthenes Aromatics Total BP>185 C 0.89 Oxygenates MTBE 7.24

4 450 PIONA+ TM Analyzer Reduced analysis time and increased sample throughput efficiency through the use of concurrent heating A unique aspect of the design of the Bruker 450 PIONA+ system is the ability to independently heat the individual traps. As shown in Figure 3, when the PIONA+ system is operated in the normal mode, a total analysis time of 180 minutes is required to elute all of the component groups. However, as shown in Figure 4, a reduction in total analysis time from 180 minutes to 95 minutes can be obtained. Such a reduction in analysis time is achieved by carefully optimizing the temperature settings of the various traps and columns, and independently heating the Molsieve traps. This is referred to as concurrent heating. This approach enables a fast PIONA mode, which results in the elution of the paraffins immediately after their naphthene and iso-paraffin counterparts. However, the elution integrity of the component groups remains intact with no negative influence on either naphthene or iso-paraffin groups, (see Figure 4 inset for a close up view of the resulting elution sequence). By employing this technique, sample throughput can be nearly doubled compared to systems that do not offer this unique capability. Figure 3. Chromatogram of a calibration mix in conventional PIONA+ mode. min Figure 4. Chromatogram of a calibration mix using concurrent heating in fast PIONA+ mode.

5 Table 2: The 450 PIONA+ TM Analyzer is extremely flexible and can be configured to run a wide variety of methods. Extreme Flexibility EN EN-ISO PNA PONA PIONA O-PONA O-PIONA X X ASTM D6839 X x DIN X x x Determining total olefin content is now practical The stability, sample loading and lifetime for all of the critical chromatographic components have been improved and thoroughly optimized in the Bruker 450 PIONA+ TM Analyzer. However, the most noteworthy improvement has been increasing the sample loading capacity of the olefin trap. As a result, it is now possible to analyze streams with olefin content as high as % or more. This makes it quite practical to employ a single analytical method to obtain total olefin content (see example report in Table 3). 450-GC based PIONA+ TM Analyzer includes Bruker 450-GC high performance gas chromatograph equipped with: Direct injection port Bruker high performance capillary column(s) (dependent on method specified at the time of order) ASTM D1319 (FIA) X x x x DIN X x x x x ASTM D5443 X x x x x UOP 870 X x x x x IP 382 X x x x x = Compliant with Method = Reports Available PIONA+ column/trap/valve cabinet Flame ionization detector (FID) Full electronic flow control (EFC) of all gases CP-8400 or CP-8410 automatic liquid sampler Galaxie data system software for system control, data acquisition and report generation Galaxie PIONA+ application software Computer/monitor Pre-loaded standard methods Factory test Reference chromatogram Reference standard for use in conducting onsite performance verification Table 3: Example weight % report for a gasoline sample with very high olefinic content; in this case 46 % (highlighted in red). Saturates Unsaturates Carbon Cyclic Iso Normal Cyclic Iso Normal Aromatics Oxyg Total Total

6 Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL , #CA Chemical Analysis Solutions GC quadrupole mass spectrometers The Bruker 300-MS series GC/MS systems stand at the pinnacle of versatility for quadrupole mass spectrometer systems. Both the 300-MS and 320-MS are configurable as either single-quadrupole, or triple-quadrupole systems. The 300-MS delivers the performance you ve come to expect from an industry leader in quadrupole innovation. It features an 800 Da mass range, superior negative ion sensitivity, and unmatched robustness in its performance class. The 320-MS delivers femtogram sensitivity, 2000 Da mass range, and a wide array of chromatographic and ionization configurations to uniquely match your needs - all in less than 72 cm. (28 in.) of linear bench space! In minutes, our 300-MS series systems can be changed from EI to CI modes of operation. Easily, our 300-MS and 320-MS are the most sensitive, robust, and flexible quadrupole GC/MS systems currently available. ICP mass spectrometers Choosing an ICP-MS for your elemental analysis needs has never been easier with the Bruker 800-MS Series. The 810-MS is the instrument of choice for routine analysis with industry leading sensitivity and intuitive Web-integrated ICP-MS Expert software. The 820-MS features Bruker s novel collision reaction interface (CRI), providing interference-free analysis and allowing you to tackle any application with ease. With a vast range of accessories, Bruker has the solution to all your ICP-MS application requirements. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen Germany Phone +49 (421) Fax +49 (421) sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) Fax +1 (978) ms-sales@bdal.com

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography. Chemical Analysis Low Level Oxygenates Analyzer Trace Analysis of Oxygenates in Hydrocarbon Matrices think forward Gas Chromatography The determination of sub to high ppm levels of ethers, alcohols, aldehydes

More information

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated

More information

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE MM 2 The new Generation of Mobile Mass Spectrometers Innovation with Integrity Defence CBRNE Picture by: MOWAG GmbH Mobile CWA Detection and Identification Low weight and high performance detector Introducing

More information

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0. System Description The VUV PIONA + Analyzer is a VGA-100 Gas Chromatography (GC) detector configured for PIONA compound analysis by the VUV PIONA + method. The VUV PIONA + method uses relatively simple

More information

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Analysis of Trace (mg/kg) Thiophene in Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application Petrochemical Authors James D. McCurry and Bruce D. Quimby Agilent Technologies

More information

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline Fast : Cycles in

More information

Automated PIONA Analysis by ASTM D8071 and VUV PIONA+

Automated PIONA Analysis by ASTM D8071 and VUV PIONA+ Automated PIONA Analysis by ASTM D8071 and VUV PIONA+ Automated PIONA Analysis by ASTM D8071 and VUV PIONA+ An Application of VUV PIONA+ for Finished Gasoline Analysis Introduction ASTM D8071 is a single

More information

Analytical Instrumentation

Analytical Instrumentation Gas Chromatography and Mass Spectrophotometry Environmental, food safety, toxicology, and forensic gas chromatography applications are more demanding than ever. Our portfolio of GC, GC- MS, GC-MS/MS and

More information

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF microtof-q III The bench-mark in accurate mass LC-MS/MS Innovation with Integrity ESI-Qq-TOF The Advantage of Confidence in Routine The microtof-q range is widely acknowledged in setting standards in performance

More information

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop

More information

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1 GC Capillary Columns 100% Dimethyl Polysiloxane GC Columns and Applications ID (mm) Film Thickness (µm) Length (m) Temperature Limits ( C) Part No. 0.32 0.5 60-60 to 320/340 054069 0.32 1 60-60 to 320/340

More information

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Characterization of petroleum samples via thermal analysis coupled to APCI FTMS Abstract Thermal analysis, by means of a thermo balance (TG), was coupled to an atmospheric pressure chemical ionization

More information

Determination of Hydrocarbon Components in Petroleum Naphthas

Determination of Hydrocarbon Components in Petroleum Naphthas Determination of Hydrocarbon Components in Petroleum Naphthas LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Petrochemical, Naphtha, Deconvolution, Retention Index 1. Introduction The

More information

The Power to See What You ve Never Been Able to See Before. Innovation with Integrity. Qq-FTMS

The Power to See What You ve Never Been Able to See Before. Innovation with Integrity. Qq-FTMS The Power to See What You ve Never Been Able to See Before Innovation with Integrity Qq-FTMS Now see what you ve never been able to see Bruker s extreme Resolution FTMS technology enables scientists to

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector Everything you need in one GC detector Universal and selective detector with

More information

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides Abstract Here we describe a two-step QC procedure for synthetic peptides. In the first step, the

More information

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform

More information

Application Note S/SL

Application Note S/SL Analysis of Ultra low Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence according to ASTM D Ultra low detection limits Excellent Sensitivity, Repeatability &

More information

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials Thermo Scientific ICP-MS solutions for the semiconductor industry Maximize wafer yields with ultralow elemental detection in chemicals and materials Trace impurity analysis in chemicals an used in the

More information

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent

More information

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS Thermo Scientific ConFlo IV Universal Interface Continuous Flow Interface Isotope Ratio MS 3 ConFlo IV Universal Interface for Continuous Flow Isotope Ratio MS The development of Continuous Flow carrier

More information

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research profileanalysis Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research Innovation with Integrity Omics Research Biomarker Discovery Made Easy by ProfileAnalysis

More information

DET REPORT. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n PARAFFINS. NO.

DET REPORT. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n PARAFFINS. NO. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n-paraffins. 2.) FINGERPRINT CHROMATOGRAMS OF GASOLINES BY SELECTIVELY DETECTING ALKANE AND OXYGENATE

More information

PONA Analysis on GSBP-PONA Column

PONA Analysis on GSBP-PONA Column PONA Analysis on GSBP-PONA Column Naizhong Zou, Beijing Chromtech Institute, Beijing, China Zack Ji, GS-Tek. Newark, DE USA 1. Introduction Gasoline, either naphtha, cracked or reformulated, contains large

More information

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR Everyday NMR Why infer when you can be sure? Innovation with Integrity NMR Only NMR gives you definitive answers, on your terms. Over the past half-century, scientists have used nuclear magnetic resonance

More information

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been

More information

ABI 3200 Q TRAP LC/MS/MS System

ABI 3200 Q TRAP LC/MS/MS System www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 ABI 3200 Q TRAP LC/MS/MS System The advantages of an ion trap and the performance of a triple quad. All in one system.

More information

Author. Abstract. Introduction

Author. Abstract. Introduction Improved Performance for the Analysis of Aromatics in Gasoline by ASTM Method D5769 Using the Agilent 5973 inert Gas Chromatography/Mass Spectrometry System Application Author James D. McCurry Agilent

More information

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan,

More information

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Agilent

More information

Making Improvements to Today s Natural Gas Analysis Systems

Making Improvements to Today s Natural Gas Analysis Systems Making Improvements to Today s Natural Gas Analysis Systems Hiroyuki Aikawa, Ryosuke Kamae, Yuki Hashi, PhD, Shimadzu (China) Co., Ltd. 1. Introduction In recent years, driven mainly by rising energy demand,

More information

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today

More information

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer Innovative 0.01 0.1 1 10 Intuitive Concentration (ppb) R = 0.99999 Versatile Hydra II C Mercury Analyzer At Teledyne Leeman Labs; atomic spectroscopy is our business our only business. We are industry

More information

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR ALPHA The very compact and smart FTIR spectrometer Innovation with Integrity FTIR ALPHA FTIR Spectrometer More than just small analyze The ALPHA is more than just a compact FTIR spectrometer: Its modular

More information

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer NIGAS The Neutron Induced Gamma Spectrometer N B C D e t e c t i o n Po Non-invasive Identification of Explosives and Chemical Warfare Agents Positioning System The NIGAS utilizes Neutron Induced Gamma

More information

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS Abstract A study was carried out using the Bruker EVOQ GC-TQ to screen a

More information

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS Designed for Accuracy High resolution quantitative proteomics Innovation with Integrity LC-MS Setting New Standards in Accuracy The development of mass spectrometry based proteomics approaches has dramatically

More information

Thermo Finnigan LTQ. Specifications

Thermo Finnigan LTQ. Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications

More information

SIFT-MS. technology overview

SIFT-MS. technology overview SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS

More information

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES JPACSM 127 AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES Trace Analytical Inc. Menlo Park, CA ABSTRACT GC based gas analyzers with Reduction Gas Detector (RGD) and Flame Ionization

More information

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) Gas Chromatography NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25) The Non-Methane Organic Compounds (NMOC) Analyzer is a gas chromatograph configured for analyzing gaseous samples for total organic

More information

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Page 1 of 13 CIPAC/4105/R GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY Prepared for CIPAC by Dr M J Tandy*, P M Clarke and B White (UK) The rapid

More information

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector New directions in science are launched by new tools much more often than

More information

Guide to Peptide Quantitation. Agilent clinical research

Guide to Peptide Quantitation. Agilent clinical research Guide to Peptide Quantitation Agilent clinical research Peptide Quantitation for the Clinical Research Laboratory Peptide quantitation is rapidly growing in clinical research as scientists are translating

More information

DI 3500 Discrete Aoalvzer

DI 3500 Discrete Aoalvzer DI 3500 Discrete Aoalvzer Automated Chemistry and Ion Analysis ':t O+Analytical:!, A World ofsolutions. - Discrete Analysis Efficient Microscale Chemistry Increasingly laboratories are being challenged

More information

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer m a s s s p e c t r o m e t r y Finnigan TC/EA High Temperature Conversion Elemental Analyzer Analyze Detect Measure Control Finnigan TC/EA High Temperature Conversion Elemental Analyzer Finnigan TC/EA

More information

Multi-residue analysis of pesticides by GC-HRMS

Multi-residue analysis of pesticides by GC-HRMS An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict

More information

LCTech GmbH Chromatographie

LCTech GmbH Chromatographie EVA III - an analytical preparation system for all kinds of applications a new system by LCTech that makes work so much easier Overview of Contents: y Broad Spectrum of Application y Automatisation of

More information

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse HRAM LC-MS profiling of > 1 urine samples demonstrates the outstanding analytical skills of the impact II Introduction

More information

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Simplified workflows for the Thermo Scientific icap TQ ICP-MS TECHNICAL NOTE 43401 Simplified workflows for the Thermo Scientific icap TQ ICP-MS Authors Marcus Manecki, Dhinesh Asogan Thermo Fisher Scientific Keywords Ease of use, Qtegra ISDS Software, Reaction Finder,

More information

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and

More information

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS Application Note Energy and Fuels - Biofuels Authors Ron Honnold, Ph.D. and Robert Kubas Agilent Technologies, Inc. Santa Clara, CA

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Translational Biomarker Core

Translational Biomarker Core Translational Biomarker Core Instrumentation Thermo Scientific TSQ Quantum Triple Quadrupole Mass Spectrometers. There are two TSQ Quantum Ultra AM instruments available in the TBC. The TSQ Quantum Ultra

More information

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + = Application ote #LC-MS 80 Simultaneous Quantitative and Qualitative Measurements in a Single Workflow to Increase Productivity in Primary Drug Metabolism Investigations At-a-Glance n Increased productivity

More information

TOXICOLOGY & FORENSIC APPLICATIONS

TOXICOLOGY & FORENSIC APPLICATIONS TOXICOLOGY & FORENSIC APPLICATIONS New Developments of Confirmation Instruments Applications in the Poison Control Centre's Thermo Scientific Instrumentation & their integrated solution s specialize in

More information

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis Automated Switching Between D-LC and Comprehensive D-LC Analysis The Agilent 90 Infinity D-LC Solution Technical Overview Author Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany Abstract This

More information

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue

More information

of mass spectrometry

of mass spectrometry Thermo Scientific 253 Ultra High resolution isotope ratio MS Discover a new world of mass spectrometry Paleoclimatology Atmospheric science Biogeochemistry Petrology Discover the isotopic anatomy of molecules

More information

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS Agilent Technologies/Wasson ECE Monomer Analyzer Application Authors Fred Feyerherm 119 Forest Cove Dr. Kingwood, TX

More information

Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples Defining quality standards for the analysis of solid samples Thermo Scientific Element GD Plus Glow Discharge Mass Spectrometer Redefine your quality standards for the elemental analysis of solid samples

More information

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note Abstract Area and retention time are the two primary measurements in gas chromatography. The precision with which

More information

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection

More information

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Monomer Analysis Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Polymer Grade Monomer Analysis Monomer Analysis Impurities in feedstocks can adversely

More information

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS Tomoko Vincent 1, Simon Lofthouse 2, Daniel Kutscher 1 and Shona McSheehy Ducos

More information

costech instruments ECS 4010 Elemental Combustion System CHNS-O

costech instruments ECS 4010 Elemental Combustion System CHNS-O instruments ECS 4010 Elemental Combustion System CHNS-O costech Costech Analytical Tecnologies Inc. 26074 Avenue Hall, Suite 14 Valencia, CA 91355 - USA Phone: (661) 297-2395 Fax: (661) 297-5492 e-mail:

More information

The Claviature of Gas Analysis

The Claviature of Gas Analysis The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern

More information

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns Martin Okiro and Robert Wohleb VICI Gig Harbor Group Inc, P.O. Box 2657, Gig Harbor,

More information

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS m a s s s p e c t r o m e t r y Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS Fully Automated Multi-Element Isotope Analysis for C, N, S, O, H Food Testing Forensics Environmental Analysis

More information

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1

More information

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis Abstract A rapid, targeted quantitative UHPLC-triple quadrupole

More information

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer APPLICATION NOTE Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer AN42266 Dr. Liliana Krotz, Dr. Francesco Leone and Dr. Guido Giazzi Thermo Fisher Scientific,

More information

110 Lowell Rd Hudson, NH USA Tel:

110 Lowell Rd Hudson, NH USA Tel: 110 Lowell Rd Hudson, NH 03051 USA Tel: 603-886-8400 www.teledyneleemanlabs.com Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental

More information

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is

More information

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Application Note # CA 284780 Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS Abstract The analysis of semi-volatile organic compounds

More information

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography Fast Analysis of Aromatic Solvent with.8 mm ID GC column Application Gas Chromatography Authors Yun Zou Agilent Technologies (Shanghai) Co. Ltd. Ying Lun Road Waigaoqiao Free Trade Zone Shanghai 3 P.R.

More information

Varian Galaxie Chromatography Data System for Preparative HPLC

Varian Galaxie Chromatography Data System for Preparative HPLC Varian Galaxie Chromatography Data System for Preparative HPLC By Gary Burce Varian, Inc. 2700 Mitchell Drive, Walnut Creek, CA 95498 USA Abstract Galaxie is an ideal chromatography data system for the

More information

Product Descriptions and Offerings

Product Descriptions and Offerings Product Descriptions and Offerings Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental analysis. Laboratories in industries ranging from environmental science, oil and

More information

HYPHENATED TECHNOLOGY GUIDE

HYPHENATED TECHNOLOGY GUIDE HYPHENATED TECHNOLOGY GUIDE TABLE OF CONTENTS TG-IR...3 Hiden Analytical MS Systems for TG-MS...4 TG-MS...5 TG-GC/MS...6 TG-IR-GC/MS...8 HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments

More information

ETD Verification Kit

ETD Verification Kit Instructions for Use ETD Verification Kit Kit for verifying and tuning electron transfer dissociation (ETD) CARE products are designed to support our worldwide customers with highquality consumables, accessories

More information

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS ESPRIT Feature Particle detection and chemical classification Innovation with Integrity EDS Fast and Comprehensive Feature Analysis Based on the speed and accuracy of the QUANTAX EDS system with its powerful

More information

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller

More information

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR CONFOCHECK Infrared Protein Analysis Innovation with Integrity FT-IR CONFOCHECK: FT-IR System for Protein Analytics FT-IR Protein Analysis Infrared spectroscopy measures molecular vibrations due to the

More information

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry The end of mass-speculation Pre-cleaned and certified vials for mass spectrometry Bonded, ultra-pure closures LC/MS and GC/MS Manufacturing the Ultimate Vial for Mass Spectrometry More than a quarter century

More information

PERSPECTIVE STABLE ISOTOPE RATIO MS

PERSPECTIVE STABLE ISOTOPE RATIO MS Nu Plasma II Multi-Collector ICP-MS Aspect HR Stable Isotope Ratio MS PERSPECTIVE STABLE ISOTOPE RATIO MS Astrum Glow Discharge MS Nu Plasma 1700 Multi-Collector ICP-MS Panorama HR Stable Isotope Ratio

More information

ionos The most advanced stable isotope software ever created

ionos The most advanced stable isotope software ever created ionos The most advanced stable isotope software ever created ionos Fast and robust data processing of the most complex samples ionos is the most advanced software ever created for the stable isotope community.

More information

Training Courses. Chromatography training from the Crawford Scientific experts

Training Courses. Chromatography training from the Crawford Scientific experts Training Courses Chromatography training from the Crawford Scientific experts HPLC Fundamentals This one-day course introduces the fundamentally important concepts associated with HPLC analysis including

More information

Reprinted from February Hydrocarbon

Reprinted from February Hydrocarbon February2012 When speed matters Loek van Eijck, Yokogawa, The Netherlands, questions whether rapid analysis of gases and liquids can be better achieved through use of a gas chromatograph or near infrared

More information

Highly Sensitive and Rugged GC/MS/MS Tool

Highly Sensitive and Rugged GC/MS/MS Tool Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction

More information

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput Yi Zhang 1, Zhiqi Hao 1, Markus Kellmann 2 and Andreas FR. Huhmer

More information

Chapter 31 Gas Chromatography. Carrier Gas System

Chapter 31 Gas Chromatography. Carrier Gas System Chapter 31 Gas Chromatography GAS-LIQUID CHROMATOGRAPHY In gas chromatography, the components of a vaporized sample are fractionated as a consequence of being partitioned between a mobile gaseous phase

More information

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,

More information

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR EM 27/SUN Series For Atmospheric Measurements Innovation with Integrity FT-IR The new EM27/SUN Series spectrometers represent FT-IR Remote Sensing analyzers dedicated for atmospheric measurements. They

More information

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT AppNote 5/2008 Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control Fred Foster, John R. Stuff, Edward Pfannkoch Gerstel, Inc., 701 Digital Drive, Suite

More information

DMA-80L TECHNICAL SPECIFICATIONS

DMA-80L TECHNICAL SPECIFICATIONS DMA-80L Advantages Determination of Mercury in water and digestates Unique atomic absorption spectrometer, optical paths with three independent signals Short analysis time, typically less than 2 minutes

More information

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Application Note Environmental Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry Authors Ye Kong and Zhe Cao Agilent Technologies,

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Applied Biosystems QStar Pulsar i Features of the API QSTAR Pulsar i The

More information

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins TECHNICAL NOTE 39 A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins Author Cristian Cojocariu Thermo Fisher Scientific, Runcorn,

More information

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance

More information

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur Combustion Ion Chromatography Fast and reliable determination of halogens and sulfur Combustion digestion and ion chromatography combined in one system 02 Combustion Ion Chromatography (CIC) extends the

More information