CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

Size: px
Start display at page:

Download "CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE"

Transcription

1 CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE Page no. 5.1 Introduction Methods and measurements Saturation thickness of elements and polymers Effective atomic number of polymers Signal-to-noise ratio Conclusions 152

2 5.1 Introduction Nondestructive nuclear radiation techniques often have a great advantage over the traditional chemical techniques used for the determination of effective atomic numbers of composite materials of various interests. For composite materials like alloys, polymers, biological materials, etc. the atomic number cannot be represented uniquely by a single number, as in the case of elements. This number, in composite materials, is called effective atomic number (Z eff )(İçelli, 2006; Prasad et al., 1998). Effective atomic number of a material is used for the interpretation of attenuation of X-ray and gamma rays by a polymer or composite materials. Effective atomic numbers of various combinations of elemental absorbers are helpful in deciding the required radiation dose to human tissues and for proper design of radiation shielding (Latha et al., 2012). The study of effective atomic number also provides conclusive information about the mixture when gamma photons interact with materials. Further, estimation of Z eff is useful in characterizing the materials useful for applications in the chemical industry, nuclear industry, space programme, scientific and engineering industries, including biological applications. 5.2 Methods and measurements In the present experimental study, the backscattered photons from targets of Carbon, Aluminium, Iron, Copper, Polypropylene, Polycarbonate, Polymethyl methacrylate (Acrylic), Polytetraflouroethylene (Teflon), and Polyvinyl chloride (PVC) were measured using a NaI(Tl) scintillation detector placed at 90 to the incident beam using gamma photons of 662 kev( 137 Cs of strength 5.8 mci). The distance of the scatterer from the detector was kept 262 mm so that the angular spread due to the detector collimator (60 mm) on the target was ± 6.5. The experimental arrangement explained in detail in Section 2.2, was 132

3 used to conduct these studies. The schematic diagram of the experimental setup is shown in Figure 5.1. Figure 5.1.: Schematic diagram of the experimental setup The Compton backscattering experiment was carried out as a function of sample thickness for the different materials listed above. The dead time corrected acquisition time of 1000 seconds was used to acquire the data. A minimum of 4 trials were run for each sample to reduce the statistical error (Knoll, 1988). A typical backscattered spectrum obtained for copper of 40 mm thickness as a scatterer is shown in Figure 5.2(a). The backscattered spectrum was processed, following the procedure explained in Section 2.9, to obtain multiple scattered photons. The same procedure was followed for all the scattering targets. 133

4 Figure 5.2.: (a) A typical experimentally observed spectrum with 40 mm thick copper target at a scattering angle of 90, (b) An observed background spectrum without target in the primary beam, (c) Background subtracted events, (d) Normalized analytically reconstructed single scattered full energy peak The typical spectra of the gamma backscattered photons for different materials such as carbon, aluminium, iron, and copper are presented in Figure 5.3. It is evident from the figure, that maximum backscattered photons are recorded for copper. This may be due to the fact that the atomic number of copper is higher, and hence, the density is higher. Further, it can be noticed that the intensity of the backscattered photons decreases with the decreasing of their atomic numbers. This observation is in accordance with the theoretical expectation that as atomic number decreases the density also decreases. 134

5 Figure 5.3.: Backscattered spectrum of carbon, aluminium, iron, and copper of thickness 40 mm The backscattering of gamma photons with respect to different thickness (5, 10, 20, 30, and 40 mm) of copper as a scatterer was studied and the corresponding results are demonstrated in Figure 5.4. It can be noticed that, as the thickness increases, the intensity of the backscattered photons increases and continues until it reaches its saturation thickness. It can be seen from the figure that the backscattered photon intensity for thicknesses 20, 30, and 40 mm are very close to each other. It has been observed from earlier studies that when the thickness of the scatterer approaches its saturation thickness, the difference in the backscattered intensity decreases, and finally, saturates. 135

6 Figure 5.4.: Variation of backscattered photons for different thicknesses of copper target 5.3 Saturation thickness of elements and polymers The number of multiple scattered counts due to the backscattering of gamma photons for various thicknesses of elements and polymers at an angle of 90 are presented in Table 5.1. As expected, the multiple scattering increases with increase in sample thickness and saturates at its saturation thickness. This process is explained in detail in Section The sudden increase in the intensity of multiple scattered photons at lower thicknesses can be seen from the table for both elements and polymers. Conversely, the incremental increase of multiple scattered photons decreases with increasing target thickness for all the targets, including polymers. 136

7 Table 5.1.: The number of multiple scattered counts for various thicknesses for different elements Thickness (mm) Multiple scattered counts Carbon 20 6,551 (Z = 6) 40 20, , , , , ,992 Aluminium 20 46,414 (Z = 13) 40 72, , , , , ,579 Iron 5 46,395 (Z = 26) 10 69, , , , ,664 Copper 5 42,452 (Z = 29) 10 63, , , , ,

8 Table 5.2.: The number of multiple scattered counts for various thicknesses for different polymers Polymers Thickness (mm) Multiple scattered counts Polycarbonate 20 13,807 (Z eff = 6.09) 40 38, , , , , , ,006 Polypropylene 20 9,651 (Z eff = 5.44) 40 23, , , , , , ,641 Polymethyl 20 11,229 methacrylate 40 32,319 (Z eff = 6.47) 60 48, , , , , ,

9 continuation of Table 5.2 Polytetrafluoroethylene (Z eff = 8.43) Polyvinyl chloride (Z eff = 13.86) Thickness (mm) Multiple scattered counts 20 30, , , , , , , , , , , , , , , ,483 The verification and validation of the experimentally obtained results is an important process and is necessary to strengthen the accuracy in the experimental measurements. To validate the results obtained, an experimental setup has been simulated using the Monte Carlo code as explained in Section The MCNP plot of target geometry is shown in Figure 5.5. The 137 Cs source of 662 kev with an active dimension of 10 mm in diameter and 6 mm in length used in the experimental study was used in the simulation study as well. The relative error noticed in the MCNP calculation was about 4%. The dotted curves are the best-fitted curves of the simulated data. 139

10 Figure 5.5.: MCNP plot of target geometry The experimental results and the results obtained through MCNP simulation studies were plotted and demonstrated in Figures 5.6 to 5.8. The plots of all the elements and polymers show that the intensity of the multiple scattered photons increases with increase in target thickness and attains saturation as explained earlier. It can be noticed that the MCNP simulation results plotted along with the experimental results agrees well and this observation validates the present experimental results. The experimental and MCNP simulation results for carbon, aluminium, iron, and copper are compared in Figure 5.6. It can be seen from the figure that the experimentally measured values agree well with the simulated data. However, a small deviation can be noticed at the lower thicknesses for elements of lower atomic numbers (aluminium and carbon). This deviation may be due to the higher signal-to-noise ratio levels at lower thickness and materials with lower atomic numbers. The single scattered photons contribute more to the backscattered spectrum compared to multiple scattered photons at lower thickness and lower density of scattering material. This may be the main factor 140

11 for the discrepancy in the experimental and MCNP results at lower thickness and lower atomic number of the scattering materials. y = a*exp (x/b) + y 0 Figure 5.6.: Multiple scattered photons as a function of target thickness for elements The variations in multiple scattered photon intensity of polymers as a function of target thickness were compared with the results of the MCNP simulated results in Figures 5.7 and 5.8. There was an overall good agreement between the experimental results and the simulated data for all the polymers used in the present investigation. 141

12 y = a*exp (x/b) + y 0 Figure 5.7.: Multiple scattered photons as a function of target thickness for Polypropylene, Polycarbonate, and Polytetraflouroethylene y = a*exp (x/b) + y 0 Figure 5.8.: Multiple scattered photons as a function of target thickness for Polymethyl methacrylate and Polyvinyl chloride 142

13 The saturation thicknesses of the elements and polymers used in this study were estimated using the processed experimental data. The comparison between the experimentally obtained and MCNP simulated saturation thicknesses for elements and polymers are tabulated in Table 5.3. It can be noticed that as expected, the saturation thickness decreases with increasing atomic or effective atomic number of the target material (column 2). The saturation thickness estimated using MCNP code is tabulated in column 4. It can be seen from the table, that the saturation thickness obtained from the MCNP simulation studies are in accordance with the experimentally measured values. The deviations between these two are tabulated in column 4 and are found to vary from 0 to 7.2 %. This observation validates and supports the experimental studies. Table 5.3.: The experimental and MCNP simulated saturation thickness Elements Z (or Saturation thickness (mm) Difference Z eff ) Experimental MCNP in % Carbon Aluminium Iron Copper Polypropylene Polycarbonate Polymethyl methacrylate Polytetrafluoroethylene Polyvinyl chloride

14 5.4 Effective atomic number of polymers Effective atomic number (Z eff ) is a convenient parameter in designing radiation shielding, computing absorbed dose and energy absorption, and build-up factors studies. Compounds or mixtures can be characterized by Z eff, by providing insight about the photon interaction processes involving absorption as well as scattering. The effective atomic number of composite materials can be found by the simple power law of the form (Taylor et al., 2012) Whereby, the relative electron fraction of the i th element Z i is given by f i, such that 1. Mayneord (Khan, 2003) used the value of exponent m in the above relation as 2.94.Hence, the above equation can be written as Using the elemental composition, the effective atomic numbers of the polymers were estimated and tabulated in column 5 of Table 5.4. A graph of experimentally measured saturation thickness versus atomic number of elements is plotted and shown in Figure 5.9. It is clear from the figure that the saturation thickness for particular incident energy of gamma photons (in this case 662 kev) decreases with increasing atomic number. 144

15 Figure 5.9.: Plot of saturation thickness for elements and polymers. Experimental errors are represented by the size of the data points From the above graph, the measured saturation thicknesses of polymers were used to assign the corresponding effective atomic numbers, and so the obtained effective atomic numbers are tabulated in column 6 of Table 5.4. It can be noticed that the effective atomic numbers obtained experimentally (column 6) compares well with the values estimated using the empirical equation (column 5). Table 5.4.:The saturation thickness and effective atomic number of selected polymers Polymer Monomer Saturation Effective atomic number Elemental thickness weightage Empirical (mm) Experimental equation Polypropylene C 3 H 6 75% C, 25% H (±0.3) Polycarbonate C 15 H 16 O 2 74% C, 13% H, 13% O (±0.4) Polymethyl C 5 O 2 H 8 55% C, 30% O, methacrylate 15% H (±0.3) Polytetrafluoroethylene C 2 F 4 25% C, 75% F (±0.4) Polyvinyl chloride C 2 H 3 Cl 38% C, 9% H, 53% Cl (±0.2) 145

16 The effective atomic numbers experimentally obtained, theoretically estimated and reported in literature are compared in Table 5.5. It can be seen from the table that experimentally measured values of the present study are very close and compares well with the empirically derived values. The percentage deviation between these values ranges from 0.6 to 8.8. This shows the very good agreement between the two. Further, it can be noticed that the values for Polyvinyl chloride reported by Naydenov et al. (2004) and Polytetrafluoroethylene reported by Prasanna Kumar et al. (2010) are comparable with the corresponding values of the present study. The values reported for Polypropylene and Polymethyl methacrylate by Kucuk et al. (2013) and for Polymethyl methacrylate by Prasanna Kumar et al. (2010) disagree and deviate by about 50 % compared to the results of the present study. Table: 5.5. :The comparison of atomic number of selected polymers with literature Polymer name Empirical equation Experimental Effective atomic number (Kucuk et al., 2013) Naydenov et al., 2004) (Prasanna Kumar et al., 2010) Polypropylene (3.6) 2.6 (52.2) - - Polycarbonate (8.8) Polymethyl methacrylate (6.8) 3.4 (47.4) (42.8) Polytetrafluoroethylene (1.0) (4.4) Polyvinyl chloride (0.6) (1.3) - Numbers in parenthesis shows the percentage deviation from the empirically derived values 146

17 5.5 Signal-to-noise ratio The ratio of the number of single scattered events to the number of multiple scattered events is considered as the signal-to-noise ratio. In Compton profiles and cross-section measurements, only single scattered photons are desired and multiple scattered photons act as background noise to the original signal. Therefore, estimation of the signal-to-noise ratio becomes one of the important parameters and plays an important role in these studies. The signal-to-noise ratio is estimated using measured multiple scattered photons and single scattered photons from reconstructed spectrum using measured FWHM values. The results obtained for the elements are tabulated in Table 5.6 and for polymers in Table 5.7. It can be noticed from Table 5.6 that the incremental increase of both single and multiple scattered photons decreases with increasing target thickness for all the targets. This observation is more predominant in the case of single scattered photons. It can also be noticed that the signal-to-noise ratio (Table 5.6, column 5) is relatively higher at lower thickness for elements. However, among the elements, it is higher by orders of magnitude in carbon compared to the other three elements aluminium, iron, and copper. Among these three elements, it is slightly higher in aluminium. This can be attributed to their lower atomic numbers. From these observations, it is evident that as the atomic number of the elements increases, the signal-to-noise ratio decreases. This signal-to-noise ratio is stable above 90 mm of thickness in case of carbon, above 60 mm in case of aluminium, above 20 mm in case of iron and it is above 15 mm of thickness in the case of copper. These results show that the signal-to-noise ratio varies with respect to both thickness and atomic number of the scatterer. Based on this observation, one can conclude that, the thicker the 147

18 scattering material, the lower the signal-to-noise ratio. In addition, higher the atomic number of the scattering material, lower the signal-to-noise ratio. Table 5.6.: The number of multiple and single scattered counts for various thicknesses for different metals Thickness (mm) Single scattered Multiple scattered Signal -tonoise ratio Carbon (Z = 6) Aluminium (Z = 13) Iron (Z = 26) Copper (Z = 29) counts counts ,135 6, ,078 20, ,489 36, ,026 49, ,433 50, ,806 50, ,953 51, ,266 46, ,627 72, ,121 85, ,647 91, ,450 93, ,698 92, ,044 94, ,786 46, ,229 69, ,077 94, , , , , , , ,536 42, ,617 63, , , , , , , , ,

19 It can be seen from Table 5.7, that the variations of multiple backscattered photons for different polymers commensurate with their thicknesses. This observation is similar to that occured in the case of elements. A similar trend to that of elements in variation in the signal-to-noise ratio, multiple and single scattered events with respect to thickness, and their effective atomic numbers have been noticed. It is very clear from the table, that signal-to-noise ratio is orders of magnitude higher for lower thicknesses of polymers, and is still more predominant in the case of materials with lowest effective atomic numbers presented in the table (ranging from 5.64 to 6.91). Table 5.7.: The number of multiple and single scattered counts for various thicknesses for different polymers Polymers Polycarbonate (Z eff = 6.09) Polypropylene (Z eff = 5.44) Polymethyl methacrylate (Z eff = 6.47) Thickness (mm) Single scattered counts Multiple scattered counts Signal -tonoise ratio ,587 13, ,502 38, ,818 52, ,531 61, ,100 65, ,076 66, ,565 67, ,508 65, ,663 9, ,829 23, ,980 42, ,542 50, ,243 53, ,325 53, ,439 55, ,060 56, ,029 11, ,183 32, ,862 48, ,215 58, ,898 63, ,963 63, ,217 63, ,311 63,

20 continuation of Table 5.7 Polytetrafluoroethylene (Z eff = 8.43) Polyvinyl chloride (Z eff = 13.86) Thickness Single scattered counts Multiple scattered counts Signal -tonoise ratio ,017 30, ,725 58, ,801 68, ,378 74, ,806 76, ,875 79, ,941 88, ,098 84, ,314 19, ,059 40, ,050 55, ,932 63, ,629 66, ,580 67, ,310 67, ,060 67, The signal-to-noise ratio for all the materials as a function their thickness are plotted in Figure It can be noticed that as the thickness increases the signal-to-noise ratio decreases. This indicates the presence of more multiple scattered photons in comparison to the single scattered events as the thickness of the scatterer increases. If, multiple scattering events are to be avoided for any particular purpose, maintaining of high signal-to-noise ratio is a must, and which can be obtained by using very thin targets. Further, it can be noticed that the higher the atomic number, the lower the signal-to-noise ratio. It is further evident from Figure 5.10, that the ratio is lowest for copper (Z=29) followed by iron (Z=26), which are elements of higher atomic numbers amongst the materials used in this investigation. The signal-to-noise ratio for aluminium (Z=13) is more than that of copper and iron as its atomic number is almost half 150

21 of iron and copper, but is closer to Polyvinyl chloride (Z eff =13.86) and Polytetrafluoroethylene (Z eff =8.43), as their atomic numbers are relatively closer to that of aluminium. The maximum signal-to-noise ratio is recorded for carbon (Z=6) followed by Polypropylene (Z eff =5.44), Polymethyl methacrylate (Z eff =6.47), and Polycarbonate (Z eff =6.09). The effective atomic numbers of all these materials are between 5 and 7. As the value of the atomic number decreases, the signal-to-noise ratio increases. Increase in atomic number of the scatterer increase its density, and thereby, it increases the intensity of the multiple scatter photons, and that may be one of the main reasons for the higher signal-to-noise ratio for elements of lower atomic numbers. y = a*exp (-x/b) + y 0 Figure 5.10.: Signal-to-noise ratio for elements and polymers 151

22 5.6 Conclusions The following conclusions are drawn from the detailed results and discussions presented above: The major contribution in the backscattering of thick targets is from multiple scattered photons, having energy equal to that of single scattered photons. The intensity of the multiple scattered events increases with increase in the target thickness and becomes almost constant beyond a particular value called saturation thickness. The saturation thickness decreases with increasing atomic number of the scattering material. There is a good agreement between the experimentally obtained results of the saturation thickness and the results obtained from the MCNP simulation studies for all the targets used in the present investigation. The effective atomic numbers of the selected polymers were estimated using their experimentally measured saturation thicknesses and they closely agree with the theoretically estimated values. The values of the effective atomic numbers of the present investigation agree well with Naydenov et al. (2004) for Polyvinyl chloride and Prasanna Kumar et al. (2010) for Polytetrafluoroethylene with a deviation of about 4%. However, the result of the present work disagrees with the reported values for Polypropylene and Polymethyl methacrylate by Kucuk et al. (2013) and for Polymethyl methacrylate by Prasanna Kumar et al. (2010). The signal-to-noise ratio decreases with the increase in atomic (or effective) atomic numbers of the scattering materials. 152

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN 316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science

More information

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN 308 Angular dependence of 662 kev multiple backscattered gamma photons in Aluminium Ravindraswami K a, Kiran K U b, Eshwarappa K M b and Somashekarappa H M c* a St Aloysius College (Autonomous), Mangalore

More information

Compton suppression spectrometry

Compton suppression spectrometry Compton suppression spectrometry In gamma ray spectrometry performed with High-purity Germanium detectors (HpGe), the detection of low intensity gamma ray lines is complicated by the presence of Compton

More information

RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS

RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS CHAPTER RESULTS AND DISCUSSION ON EFFECT OF COLLIMATOR SIZE ON THE ATTENUATION OF GAMMA RAY IN PURE ELEMENTS 5.1 INTRODUCTION The increasing use of isotopes in the field of medicine and biology has demands

More information

Attenuation of Radiation in Matter. Attenuation of gamma particles

Attenuation of Radiation in Matter. Attenuation of gamma particles Attenuation of Radiation in Matter In this experiment we will examine how radiation decreases in intensity as it passes through a substance. Since radiation interacts with matter, its intensity will decrease

More information

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 3, JUNE 2002 1547 A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate Wanno Lee, Gyuseong Cho, and Ho

More information

PHYS 3650L - Modern Physics Laboratory

PHYS 3650L - Modern Physics Laboratory PHYS 3650L - Modern Physics Laboratory Laboratory Advanced Sheet Photon Attenuation 1. Objectives. The objectives of this laboratory exercise are: a. To measure the mass attenuation coefficient at a gamma

More information

Scholars Research Library. Gamma Ray Photon Interaction Studies of Cu in the Energy Range 10keV to 1500keV

Scholars Research Library. Gamma Ray Photon Interaction Studies of Cu in the Energy Range 10keV to 1500keV Available online at www.scholarsresearchlibrary.com Archives of Physics Research, 202, 3 ():60-69 (http://scholarsresearchlibrary.com/archive.html) ISSN : 0976-0970 CODEN (USA): APRRC7 Gamma Ray Photon

More information

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 4 No. 2 Oct. 2013, pp. 408-412 2013 Innovative Space of Scientific Research Journals http://www.issr-journals.org/ijias/ An Optimized

More information

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1) Project Memorandum To : Jebediah Q. Dingus, Gamma Products Inc. From : Patrick R. LeClair, Material Characterization Associates, Inc. Re : 662 kev Gamma ray shielding Date : January 5, 2010 PH255 S10 LeClair

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(6):693-706 Gamma ray photon interaction studies of Cr

More information

Researchers at the University of Missouri-Columbia have designed a triple crystal

Researchers at the University of Missouri-Columbia have designed a triple crystal Childress, N. L. and W. H. Miller, MCNP Analysis and Optimization of a Triple Crystal Phoswich Detector, Nuclear Instruments and Methods, Section A, 490(1-2), 263-270 (Sept 1, 2002). Abstract Researchers

More information

Sample Spectroscopy System Hardware

Sample Spectroscopy System Hardware Semiconductor Detectors vs. Scintillator+PMT Detectors Semiconductors are emerging technology - Scint.PMT systems relatively unchanged in 50 years. NaI(Tl) excellent for single-photon, new scintillation

More information

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT Proceedings of the Eleventh EGS4 Users' Meeting in Japan, KEK Proceedings 2003-15, p.107-113 ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT K. Noto and

More information

Slides by: Prof. Abeer Alharbi

Slides by: Prof. Abeer Alharbi Slides by: Prof. Abeer Alharbi electromagnetic radiation of high energy. They are produced by sub-atomic particle interactions, such as electron-positron annihilation, neutral pion decay, radioactive decay,

More information

III. Energy Deposition in the Detector and Spectrum Formation

III. Energy Deposition in the Detector and Spectrum Formation 1 III. Energy Deposition in the Detector and Spectrum Formation a) charged particles Bethe-Bloch formula de 4πq 4 z2 e 2m v = NZ ( ) dx m v ln ln 1 0 2 β β I 0 2 2 2 z, v: atomic number and velocity of

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron

More information

Chapter 2 Methods Based on the Absorption of Gamma-Ray Beams by Matter

Chapter 2 Methods Based on the Absorption of Gamma-Ray Beams by Matter Chapter 2 Methods Based on the Absorption of Gamma-Ray Beams by Matter Abstract Physical effects of a gamma-ray beam passing through matter as a basis for soil density determination is discussed. These

More information

Gamma-Spectrum Generator

Gamma-Spectrum Generator 1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/

More information

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation S. Moriuchi, M.Tsutsumi2 and K. Saito2 Nuclear safety technology Center,

More information

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system

More information

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS S. Prasad *, A. Enqvist, S. D. Clarke, S. A. Pozzi, E. W. Larsen 1 Department of Nuclear Engineering and Radiological

More information

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts M.L. McConnell, D.J. Forrest, J. Macri, M. McClish, M. Osgood, J.M. Ryan, W.T. Vestrand and C. Zanes Space Science Center University

More information

Monte Carlo Characterization of a Pulsed Laser-Wakefield Driven Monochromatic X-Ray Source

Monte Carlo Characterization of a Pulsed Laser-Wakefield Driven Monochromatic X-Ray Source 2009 IEEE Nuclear Science Symposium Conference Record N30-3 Monte Carlo Characterization of a Pulsed Laser-Wakefield Driven Monochromatic X-Ray Source S. D. Clarke, S. A. Pozzi, IEEE Member, N. Cunningham,

More information

International Journal of Scientific Research and Reviews

International Journal of Scientific Research and Reviews Research article Available online www.ijsrr.org ISSN: 2279 0543 International Journal of Scientific Research and Reviews Measurement of Linear and Mass Absorption Coefficients in some soil samples foruse

More information

Compton Camera. Compton Camera

Compton Camera. Compton Camera Diagnostic Imaging II Student Project Compton Camera Ting-Tung Chang Introduction The Compton camera operates by exploiting the Compton Effect. It uses the kinematics of Compton scattering to contract

More information

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide Nuclear Medicine Imaging Systems: The Scintillation Camera List of Nuclear Medicine Radionuclides Tc99m 140.5 kev 6.03 hours I-131 364, 637 kev 8.06 days I-123 159 kev 13.0 hours I-125 35 kev 60.2 days

More information

Shielding of Ionising Radiation with the Dosimetry & Shielding Module

Shielding of Ionising Radiation with the Dosimetry & Shielding Module Shielding of Ionising Radiation with the Dosimetry & Shielding Module J. Magill Overview Biological Effects of Ionising Radiation - Absorber dose, Quality or Weighting Factor, Equivalent Dose Attenuation

More information

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector A. H. D. Rasolonjatovo 1, T. Shiomi 1, T. Nakamura 1 Y. Tsudaka 2, H. Fujiwara 2, H. Araki 2, K. Matsuo 2, H. Nishizawa 2 1 Cyclotron

More information

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools 10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium

More information

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT: NUCLEAR MEDICINE Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Introduction to Medical Imaging: Physics, Engineering and Clinical Applications, by Nadine Barrie Smith

More information

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 212, 4(1):118-124 Research Article ISSN : 975-7384 CODEN(USA) : JCPRC5 Photon interaction cross-section of elemental solids

More information

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence 2009 IEEE Nuclear Science Symposium Conference Record N04-4 Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence W.J. Walsh, S.D. Clarke, S.A. Pozzi, IEEE

More information

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy LLNL-TR-518852 A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy S. Friedrich December 6, 2011 Disclaimer This document was prepared as an account of work sponsored by

More information

Figure 1. Decay Scheme for 60Co

Figure 1. Decay Scheme for 60Co Department of Physics The University of Hong Kong PHYS3851 Atomic and Nuclear Physics PHYS3851- Laboratory Manual A. AIMS 1. To learn the coincidence technique to study the gamma decay of 60 Co by using

More information

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values. EXPERIMENT 2.1 GAMMA ENERGY CALIBRATION 1- Turn the power supply on to 900 V. Turn the NIM crate on to power the amplifiers. Turn the Oscilloscope on to check the gamma pulses. The main amplifier should

More information

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data Indian Journal of Pure & Applied Physics Vol. 54, Februray 2016, pp. 137-143 Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental

More information

arxiv: v1 [physics.ins-det] 29 Jun 2011

arxiv: v1 [physics.ins-det] 29 Jun 2011 Performance simulation of a MRPC-based PET Imaging System arxiv:1106.5877v1 [physics.ins-det] 29 Jun 2011 A. Banerjee, S. Chattopadhyay April 16, 2018 Abstract The low cost and high resolution gas-based

More information

Radhakrishnan B*, Kurup P G G**, Ramakrishnan G***, Chandralingam S****

Radhakrishnan B*, Kurup P G G**, Ramakrishnan G***, Chandralingam S**** Photon Interaction Cross Section of Materials in Heterogeneous Energy Spectrum of Medical Diagnostic X-Ray Beam Radhakrishnan B*, Kurup P G G**, Ramakrishnan G***, Chandralingam S**** *Senior Medical Physicist,

More information

X-ray Absorption Spectroscopy

X-ray Absorption Spectroscopy X-ray Absorption Spectroscopy Nikki Truss November 26, 2012 Abstract In these experiments, some aspects of x-ray absorption spectroscopy were investigated. The x-ray spectrum of molybdenum was recorded

More information

Radionuclide Imaging MII Positron Emission Tomography (PET)

Radionuclide Imaging MII Positron Emission Tomography (PET) Radionuclide Imaging MII 3073 Positron Emission Tomography (PET) Positron (β + ) emission Positron is an electron with positive charge. Positron-emitting radionuclides are most commonly produced in cyclotron

More information

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information. Experimental and Monte Carlo determination of Gamma Spectrometry Efficiency Pavel Dryak, Petr Kovář Czech Metrology Institute February 2009 Leading motive of our testing The producer send the drawing after

More information

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays Alison V. Goodsell, William S. Charlton alisong@tamu.edu, charlton@ne.tamu.edu Nuclear Security Science & Policy Institute Texas A&M University,

More information

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Neutron and Gamma Ray Imaging for Nuclear Materials Identification Neutron and Gamma Ray Imaging for Nuclear Materials Identification James A. Mullens John Mihalczo Philip Bingham Oak Ridge National Laboratory Oak Ridge, Tennessee 37831-6010 865-574-5564 Abstract This

More information

DETERMINATION OF X-RAY TOTAL ATTENUATION COEFFICIENT IN Zr, Ag, In FOR ENERGY RANGE BETWEEN kev

DETERMINATION OF X-RAY TOTAL ATTENUATION COEFFICIENT IN Zr, Ag, In FOR ENERGY RANGE BETWEEN kev Vol. 93 (1998) ACTA PHYSICA POLONICA A No. 5-6 DETERMINATION OF X-RAY TOTAL ATTENUATION COEFFICIENT IN Zr, Ag, In FOR ENERGY RANGE BETWEEN 10.5-111.9 kev U. TURGUT, E. BÚYUKKASAP, O. SIΜSΕΚ, Μ. ERTUĜRUL

More information

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly.

(10%) (c) What other peaks can appear in the pulse-height spectrum if the detector were not small? Give a sketch and explain briefly. Sample questions for Quiz 3, 22.101 (Fall 2006) Following questions were taken from quizzes given in previous years by S. Yip. They are meant to give you an idea of the kind of questions (what was expected

More information

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber CYRIC Annual Report 2001 V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber Kawata N. Baba M. Kato M.*, Miura T.**, and Yamadera A.***, Cyclotron and Radioisotope Center, Tohoku

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(4): 899-903 Measurement of mass and linear attenuation

More information

K 40 activity and Detector Efficiency

K 40 activity and Detector Efficiency K 40 activity and Detector Efficiency Your goal in this experiment is to determine the activity of a salt substitute purchased in a local store. The salt subsitute is pure KCl. Most of the potassium found

More information

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices Week 7: Ch. 0 Spec. w/ Scintillation Ctrs. multiplier Devices Spectroscopy with Scint. Counters -- gamma-ray interactions, reprise -- observed spectra --- spectral components, backscatter --- summing --

More information

Calculating standard captured spectra of formation elements

Calculating standard captured spectra of formation elements 1007/s12182-012-0231-8 463 Calculating standard captured spectra of formation elements Wu Wensheng, Xiao Lizhi, Zhang Lijuan and Niu Wei State Key Laboratory of Petroleum Resource and Prospecting, China

More information

Research Article Coherent and Incoherent Scattering Cross Sections of Some Lead and Sodium Compounds at Angles below 10 for 241 Am Gamma Rays

Research Article Coherent and Incoherent Scattering Cross Sections of Some Lead and Sodium Compounds at Angles below 10 for 241 Am Gamma Rays Physics Research International Volume 14, Article ID 594767, 4 pages http://dx.doi.org/.1155/14/594767 Research Article Coherent and Incoherent Scattering Cross Sections of Some Lead and Sodium Compounds

More information

THE COMPTON EFFECT Last Revised: January 5, 2007

THE COMPTON EFFECT Last Revised: January 5, 2007 B2-1 THE COMPTON EFFECT Last Revised: January 5, 2007 QUESTION TO BE INVESTIGATED: How does the energy of a scattered photon change after an interaction with an electron? INTRODUCTION: When a photon is

More information

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee Photon interactions Photoelectric effect Compton scatter Pair production μ= τ + σ + κ μ = Total cross section τ = Photoelectric

More information

Advanced lab course for Bachelor s students

Advanced lab course for Bachelor s students Advanced lab course for Bachelor s students Versuch T2 Gamma spectroscopy and Compton scattering February 2018 Prerequisites Interactions of photons and matter Working principle and usage of scintillation

More information

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN Problem P7 Stéphanie Ménard Dosimetry Department 92262 Fontenay-aux aux-roses FRANCE What are the applications of Gamma-Ray Spectrometry in Radiological Protection and in Safety? In the environment: after

More information

Experimental study of some shielding parameters for composite shields

Experimental study of some shielding parameters for composite shields Journal of Physics: Conference Series PAPER OPEN ACCESS Experimental study of some shielding parameters for composite shields To cite this article: Ahmed F Mkhaiber and Abdulraheem Dheyaa 2018 J. Phys.:

More information

Monte Carlo modelling of a NaI(Tl) scintillator detectors using MCNP simulation code

Monte Carlo modelling of a NaI(Tl) scintillator detectors using MCNP simulation code Journal of Materials and Environmental Sciences ISSN : 2028-2508 Copyright 2017, University of Mohammed Premier Oujda Morocco J. Mater. Environ. Sci., 2017 Volume 8, Issue 12, Page 4560-4565 http://www.jmaterenvironsci.com

More information

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use Final report on DOE project number DE-FG07-99ID13772 High Pressure Xenon Gamma-Ray Spectrometers for Field Use Principle Investigator: Glenn K. Knoll Co-investigator: David K. Wehe, Zhong He, University

More information

X-RAY SPECTRA. Theory:

X-RAY SPECTRA. Theory: 12 Oct 18 X-ray.1 X-RAY SPECTRA In this experiment, a number of measurements involving x-rays will be made. The spectrum of x-rays emitted from a molybdenum target will be measured, and the experimental

More information

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT Copyright JCPDS - International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 363 MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT J.E. Fernández, V.

More information

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Chikkappa Udagani Abstract: This paper presents the precise method to estimate the dependence of linear and mass

More information

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator 88 The 1 st NPRU Academic Conference SCI-O11 Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator P. Limkitjaroenporn and W.Chewpraditkul Radiation Physics Laboratory,

More information

SOME ASPECTS OF MONTE CARLO SIMULATION FOR EFFICIENCY CALIBRATION OF GERMANIUM DETECTORS

SOME ASPECTS OF MONTE CARLO SIMULATION FOR EFFICIENCY CALIBRATION OF GERMANIUM DETECTORS ICRM Gamma Spectrometry Workshop Paris, France 23-24 February 2009 SOME ASPECTS OF MONTE CARLO SIMULATION S.Hurtado Universidad de Sevilla SPAIN 1 MONTE CARLO SIMULATION DISADVANTAGES Self-absorption correction

More information

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY R.M. Keyser New Product Development, ORTEC, 801 South Illinois Avenue, Oak Ridge, TN 37831 1 INTRODUCTION

More information

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data Harold Rothfuss a,b, Larry Byars c, Michael E. Casey a, Maurizio

More information

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool 13461 Victor Potapov, Alexey Safronov, Oleg Ivanov, Sergey Smirnov, Vyacheslav Stepanov National Research

More information

Determination of the shielding power of different materials against gamma radiation

Determination of the shielding power of different materials against gamma radiation Determination of the shielding power of different materials against gamma radiation Chow Wing Yan, Yeung Chun Lap S.K.H Tsang Shiu Tim Secondary School Wong Ka Wing Baptist Lui Ming Choi Secondary School

More information

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research,, 4(9):485-49 Research Article ISSN : 975-7384 CODEN(USA) : JCPRC5 Studies on Mass & linear attenuation coefficients of γ-

More information

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2012, 4(9):4359-4363 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Photoelectric cross sections deduced from the

More information

Quality Assurance. Purity control. Polycrystalline Ingots

Quality Assurance. Purity control. Polycrystalline Ingots Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic

More information

MC simulation of a PGNAA system for on-line cement analysis

MC simulation of a PGNAA system for on-line cement analysis Nuclear Science and Techniques 21 (2010) 221 226 MC simulation of a PGNAA system for on-line cement analysis YANG Jianbo 1 TUO Xianguo 1,* LI Zhe 1 MU Keliang 2 CHENG Yi 1 MOU Yunfeng 3 1 State Key Laboratory

More information

MCNP analysis and optimization of a double crystal phoswich detector

MCNP analysis and optimization of a double crystal phoswich detector EURONS I3 506065 JRA9 RHIB Report made during stay IEM-CSIC Madrid January 2008 MINISTERIO DE ASUNTOS EXTERIORES Y DE COOPERACIÓN AECI VICESECRETARÍA GENERAL MCNP analysis and optimization of a double

More information

Gamma Spectroscopy. Calligaris Luca Massironi Andrea Presotto Luca. Academic Year 2006/2007

Gamma Spectroscopy. Calligaris Luca Massironi Andrea Presotto Luca. Academic Year 2006/2007 Gamma Spectroscopy Calligaris Luca Massironi Andrea Presotto Luca Academic Year 2006/2007 Abstract Here we propose the results of a number of experiments with gamma rays. In the first part we concentrated

More information

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137 TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137 AUTHORS: J. Cardoso, L. Santos, C. Oliveira ADRESS: Instituto Tecnológico e Nuclear Estrada Nacional 10; 2686-953 Sacavém;

More information

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na Ellen Simmons 1 Contents Introduction Review of the Types of Radiation Charged Particle Radiation Detection Review of Semiconductor

More information

An Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles

An Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles An Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles 1) A Kumar 1 and A.J. Waker 1 Faculty of Energy System and Nuclear Science, UOIT, 2000 Simcoe St. N,

More information

Basic physics Questions

Basic physics Questions Chapter1 Basic physics Questions S. Ilyas 1. Which of the following statements regarding protons are correct? a. They have a negative charge b. They are equal to the number of electrons in a non-ionized

More information

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods Asian J. Exp. Sci., Vol. 28, No. 2, 2014; 23-31 Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods Rahim Khabaz, Farhad Yaghobi

More information

Experimental and Theoretical Investigation of Gamma Attenuation of Building Materials

Experimental and Theoretical Investigation of Gamma Attenuation of Building Materials Journal of Nuclear and Particle Physics 217, 7(1): 6-13 DOI: 1.5923/j.jnpp.21771.2 Experimental and Theoretical Investigation of Gamma Attenuation of Building Materials Ali H. Taqi *, Hero J. Khalil Department

More information

Spectral Filtering for Improving Quality of Material Discrimination Using Dual Energy X-rays

Spectral Filtering for Improving Quality of Material Discrimination Using Dual Energy X-rays Spectral Filtering for Improving Quality of Material Discrimination Using Dual X-rays Y. M. Gil, Y. S. Lee, M. H. Cho, and W. Namgung POSTECH, PAL POSTECH Abstract The well-known dual energy method of

More information

Interaction of charged particles and photons with matter

Interaction of charged particles and photons with matter Interaction of charged particles and photons with matter Robert Miyaoka, Ph.D. Old Fisheries Center, Room 200 rmiyaoka@u.washington.edu Passage of radiation through matter depends on Type of radiation

More information

Determination of the activity of radionuclides

Determination of the activity of radionuclides BUREAU NATIONAL DE MÉTROLOGIE COMMISSARIAT À L'ÉNERGIE ATOMIQUE LABORATOIRE NATIONAL HENRI BECQUEREL Note technique LNHB/04-33 Determination of the activity of radionuclides contained in volume samples

More information

Vanadium Compounds: As Gamma Rays Shielding Material

Vanadium Compounds: As Gamma Rays Shielding Material Asian Journal of Engineering and Applied Technology ISSN 2249-068X Vol. 1 No. 2, 2012, pp.53-58 The Research Publication, www.trp.org.in Vanadium Compounds: As Gamma Rays Shielding Material HarRavinder

More information

X-ray Spectroscopy. c David-Alexander Robinson & Pádraig Ó Conbhuí. 14th March 2011

X-ray Spectroscopy. c David-Alexander Robinson & Pádraig Ó Conbhuí. 14th March 2011 X-ray Spectroscopy David-Alexander Robinson; Pádraig Ó Conbhuí; 08332461 14th March 2011 Contents 1 Abstract 2 2 Introduction & Theory 2 2.1 The X-ray Spectrum............................ 2 2.2 X-Ray Absorption

More information

CHAPTER 2 INTERACTION OF RADIATION WITH MATTER

CHAPTER 2 INTERACTION OF RADIATION WITH MATTER CHAPTER 2 INTERACTION OF RADIATION WITH MATTER 2.1 Introduction When gamma radiation interacts with material, some of the radiation will be absorbed by the material. There are five mechanisms involve in

More information

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important

More information

The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries

The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries Ronald M. Keyser ORTEC 801 South Illinois Avenue Oak Ridge, TN 37831 Abstract The accurate

More information

Georgia Institute of Technology. Radiation Detection & Protection (Day 3)

Georgia Institute of Technology. Radiation Detection & Protection (Day 3) Georgia Institute of Technology The George W. Woodruff School of Mechanical Engineering Nuclear & Radiological Engineering/Medical Physics Program Ph.D. Qualifier Exam Spring Semester 2009 Your ID Code

More information

Compton Camera with PositionSensitive Silicon Detectors

Compton Camera with PositionSensitive Silicon Detectors University of Ljubljana Faculty of mathematics and physics Andrej Studen Compton Camera with PositionSensitive Silicon Detectors Doctoral thesis Supervisor: Professor Marko Mikuž Outline: Motivation Basic

More information

The GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes

The GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes The GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes R. Marc Kippen Space and Remote Sensing Sciences Group, Los Alamos National Laboratory NIS-2, MS

More information

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums Nuclear Science and Techniques 4 (13) 63 Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums QIAN Nan 1 WANG Dezhong 1,* WANG Chuan ZHU Yuelong MAUERHOFER Eric

More information

ATTENUATION STUDIES ON DRY AND HYDRATED CROSS-LINKED HYDROPHILIC COPOLYMER MATERIALS AT 8.02 TO kev USING X-RAY FLUORESCENT SOURCES

ATTENUATION STUDIES ON DRY AND HYDRATED CROSS-LINKED HYDROPHILIC COPOLYMER MATERIALS AT 8.02 TO kev USING X-RAY FLUORESCENT SOURCES Journal of Physical Science, Vol. 18(1), 23 32, 27 23 ATTENUATION STUDIES ON DRY AND HYDRATED CROSS-LINKED HYDROPHILIC COPOLYMER MATERIALS AT 8.2 TO 28.43 kev USING X-RAY FLUORESCENT SOURCES Sabar Bauk

More information

Mass Attenuation Coefficients of Lead Nitrate Dilute Solutions for 13.5 cm Thickness at 1173 and 1333 kev

Mass Attenuation Coefficients of Lead Nitrate Dilute Solutions for 13.5 cm Thickness at 1173 and 1333 kev Mass Attenuation Coefficients of Lead Nitrate Dilute Solutions for 13.5 cm Thickness at 1173 and 1333 kev Madhuri Dumpala 1, A.S.Nageswara Rao 2 Assistant Professor, Department of Physics, OsmaniaUniversity

More information

Modern Physics. Laboratory Experiment. Compton Scattering. Boston University International Program. Technische Universität Dresden

Modern Physics. Laboratory Experiment. Compton Scattering. Boston University International Program. Technische Universität Dresden Modern Physics Laboratory xperiment Compton Scattering Boston University International Program Technische Universität Dresden Spring/Summer 009 1 COMPTO SCATTRIG Determination of the nergy γ of Scattered

More information

Interaction of Particles and Matter

Interaction of Particles and Matter MORE CHAPTER 11, #7 Interaction of Particles and Matter In this More section we will discuss briefly the main interactions of charged particles, neutrons, and photons with matter. Understanding these interactions

More information

Gamma Spectroscopy. References: Objectives:

Gamma Spectroscopy. References: Objectives: Gamma Spectroscopy References: G.F. Knoll, Radiation Detection and Measurement (John Wiley & Sons, New York, 2000) W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-to Approach,

More information

Interaction theory Photons. Eirik Malinen

Interaction theory Photons. Eirik Malinen Interaction theory Photons Eirik Malinen Introduction Interaction theory Dosimetry Radiation source Ionizing radiation Atoms Ionizing radiation Matter - Photons - Charged particles - Neutrons Ionizing

More information

Study of the feasibility of a compact gamma camera for real-time cancer assessment

Study of the feasibility of a compact gamma camera for real-time cancer assessment Study of the feasibility of a compact gamma camera for real-time cancer assessment L. Caballero Instituto de Física Corpuscular - CSIC - University of Valencia; C/Catedrático José Beltrán, 2; E-46980;

More information

Progress in Nuclear Science and Technology, Volume 6,

Progress in Nuclear Science and Technology, Volume 6, DOI: 1.15669/pnst.6 Progress in Nuclear Science and Technology Volume 6 (19) pp. 1-16 ARTICLE A study on calculation method of duct streaming from medical linac rooms Takuma Noto * Kazuaki Kosako and Takashi

More information