1 Recent developments in measuring permeation through barrier films and understanding of permeation processes H. Nörenberg, Technolox Ltd., Oxford, UK and V. M. Burlakov, Department of Materials, University of Oxford, Oxford, UK Key Words: Permeation barrier coatings Moisture permeation Gas permeation Modeling ABSTRACT A novel permeation measurement system with a mass spectrometer as detector has been set up. Test measurements on barrier layers gave a lower detection limit for WVTR of about 5x10-5 g/m 2 /day. The advantage of the mass spectrometric method is, that it can be used to study the permeation a wide range of gases or vapours. Proof of principle measurements have been carried out for position resolved permeation studies. The method could be used to measure the rate of permeation through samples other than films such as electronic components (batteries) and through the edges of samples. Theoretical studies of the pressure dependence of the rate of permeation of gases through polymer films (example: OPP) showed, that the pressure dependence of gas transport through these layers is caused by an effective decrease in the diffusion activation energy after gas sorption. The mechanism causing this decrease is related to saturation of deep traps so that fast-diffusion channels possessing lower activation energy are created. This confines mass transport to a network of shallow traps INTRODUCTION The implementation of experiments to measure rates of permeation at an extremely low level and the understanding of the permeation process itself are the key to the future progress in the area of barrier layers. OLED development and quality control, for instance, require a magic rate of water vapor transmission (WVTR) of about 10-6 g/m 2 /day or less [1]. The Calcium test is widely used to estimate the WVTR. However, the Calcium test is restricted to chemically reacting permeants such as water vapor and oxygen. Permeation measurements based on a mass spectrometer as detector have been reported for permeation of a variety of gases and water vapor through polymers [2-3]. Permeation of gases and vapors through barrier layers may be influenced by a number of parameters. Experimental observations showed, that even permeation of inert gases through simple polymers is pressuredependent [3-4]. EXPERIMENTS Figure 1 shows a schematic view of the experimental set up. The ultra-high vacuum (UHV) system consists of two chambers, which allows the conditioning of the sample S in the preparation chamber P before introducing it into the investigation chamber I. The investigation chamber I is equipped with a quadrupole mass spectrometer MS to detect the partial pressure and a xyz-stage for sample manipulation. A gas container is filled with water vapour similar to the procedure described in [1]. After introduction of the gas container with the sample into the preparation chamber P and evacuating to a sufficiently low vacuum level, the sample is then transferred into the investigation chamber I by means of a transfer arm and positioned to face the mass spectrometer MS. The partial pressure of water vapour of the unknown test sample is measured. With the known values for the partial pressure of water vapour and the WVTR of a calibration sample the WVTR of the test sample can be calculated. Figure 1. Schematic view of experimental set up with preparation chamber P and investigation chamber I, S: sample, MS: mass spectrometer RESULTS AND DISCUSSION Sensitive WVTR measurements Figure 2 illustrates the capability of the mass spectrometric method. The partial pressure of a calibration sample and a barrier sample is shown as 2004 Society of Vacuum Coaters 505/
2 function of time. The calibration sample was 0.1 mm thick foil of PEN with a WVTR of 1.25 g/m 2 /day (@40ºC). clear maximum at x=0 and decreases to both sides. The variation of partial pressure, which is the contrast of the permeation, is about 1x10-9 mbar or 30% between the center and 1 mm off center. This variation is the proof of principle for position resolved permeation measurements. Figure 2. Partial pressure as function of time for a barrier sample and a calibration sample (PEN) At about t=12 h (fig. 2) the sample mounted on the gas container was introduced into the investigation chamber. The water vapour coming from the gas container leads to an increase of the partial pressure of the water vapour signal. There is a pronounced increase of the water vapour partial pressure for the PEN sample. As figure 2 shows, the partial pressure settles around 2.5x10-9 mbar, which corresponds to a WVTR of 1.25 g/m 2 /day. For the barrier layer, the increase of the water vapour partial pressure is less pronounced. Figure 2 shows, that the increase in the partial pressure of the water vapour of the barrier layer is less than 10-4 g/m 2 /day. This means, that the current experimental set-up has a dynamic range of at least 6 orders of magnitude (see also ref. [3]) and a lower detection limit of about 5x10-5 g/m 2 /day is estimated. The lower detection limit may depend on the nature of the sample (i.e. whether outgasing occurs). In order to obtain the high dynamic range of sensitivity for water vapour H 18 2 O was used [2]. Figure 3. Partial pressure as function of lateral displacement (sample: PEN) Theoretical calculations A phenomenological model for diffusion of molecules through polymer substrates has been developed [5]. The diffusion is modelled as random hopping over a potential barrier of the diffusion activation energy E act between sites. These sites have random sorption site energies. At t=0 the polymer is free of the permeant gas. The gas then enters and diffuses through the polymer. Figure 4 shows the situation at t>0. Some gas atoms are already inside the polymer occupying sorption sites that had a low enough energy to trap these atoms (black spots in fig. 1, unoccupied sorption sites are shown as circles). Once the site is occupied, the pathway through this site is blocked. The gas atoms take pathways, which do not contain such deep trap sites and can therefore diffuse faster. Position resolved permeation measurements To study the permeation position-resolved, the gas container with the sample was positioned very close to the mass spectrometer. The sample was of a piece of PEN film of about 1mm exposed diameter. Outside this exposed area the sample was covered with impermeable material. The sample was moved across the mass spectrometer by means of the xyz-stage (see figure 1), so that different areas of the sample were exposed to the ionizing region of the mass spectrometer at each point of measurement. Figure 3 shows the partial pressure as function of lateral replacement. As the sample moves across the mass spectrometer, the partial pressure shows a 2004 Society of Vacuum Coaters 505/
3 Figure 4. Model of diffusion of small molecules through a polymer. The sample is divided into N slices perpendicular to the concentration gradient. Molecules enter from the left hand side. Formally the dependence of permeation upon the gas ambient pressure is taken into account via the dependence of the activation energy for gas diffusion E act upon the gas concentration n(x,t) 0 E (,) xt = E 1 α nxt (,) (1) act act ( ) 0 where Eact and α are constants. Solving numerically the diffusion equation with a space- and time-dependent activation energy given by Eq. (1) nxt (,) Eact (,) xt = D0 exp t kt 2 2 (2) nxt (,) 0 nxt (,) + α 2 Eact, x x and taking into account the gas solubility through the boundary conditions, we simulated the permeation process as a function of time. The consequence of having such fast channels is, that at a high pressure on the feeding side a higher rate of permeation is achieved. At a low pressure, there is a higher probability that gas atoms become trapped at unoccupied deep trap sites, which slows down mass transport. The model is used to study the transient behaviour of the rate of permeation. Figure 5. Comparison of experimental data with calculations Figure 5 compares experimental data and the results from the calculations. Experimental data were used from Xenon permeation through an OPP sample (for details see [3]). Input parameters are the solubility, the diameter of the permeating gas atoms and the activation energy for diffusion. Figure 5 shows, that the model is capable of reproducing experimental results with good accuracy. Hence, the random distribution of sorption site energies is indeed responsible for the pressure dependence of the rate of permeation. A further advantage of the method is, that the results obtained for one gas can be used as input to predict the transient behaviour P=P(t) of other gases through the polymer. CONCLUSION A method to measure WVTR with a mass spectrometer as detector was set up. Test measurements gave a lower detection limit of about 5x10-5 g/m 2 /day WVTR. As the mass spectrometer can detect a wide range of gases and vapours, the application the method is not restricted to measure WVTR. It has potential for the study of permeation in other applications such as vacuum insulating panels, where the permeation of all gases from the environment is of great interest. Proof of principle for position resolved permeation measurements has been obtained. In this mode, the sample is moved with respect to the mass spectrometer giving the rate of permeation along a line or as a twodimensional pattern on the sample. A phenomenological model has been developed to describe the transient permeation of gas through a 2004 Society of Vacuum Coaters 505/
4 polymer membrane. The distribution of the trap site energies accounts for the observed pressure-dependent permeation of heavy noble gases through OPP. REFERENCES 1. H.-C. Langowski, A. Melzer and D. Schubert, Ultra High Barrier Layers for Technical Applications SVC 45 th Annual Technical Conference Proceedings, 45, 471, H. Nörenberg, T. Miyamoto, G. D. W. Smith, G. A. D. Briggs and Y. Tsukahara, Mass spectrometric estimation of gas permeation coefficients for thin polymer membranes Rev. Sci. Instruments, 70, 2414, H. Nörenberg, V. M. Burlakov, H.-J. Kosmella, G. D. W. Smith, G. A. D. Briggs and Y. Tsukahara, Permeation of noble gases (He, Ne, Ar, Kr, Xe) through thin membranes of OPP studied by mass spectroscopy Polymer 42, 10021, Y. Naito, K. Mizoguchi, K. Terada and Y. Kamiya, The Effect of Pressure on Gas Permeation Through Semicrystalline Polymers above the Glass Transition Temperature Journal of Polymer Science: Part B: Polymer Physics, 29, 457, V. M. Burlakov, H. Nörenberg, G.A.D. Briggs and Y. Tsukahara, Model for the Pressure-Dependent Permeation of Small Molecules through a Polymer Membrane Journal of Polymer Science: Part B: Polymer Physics, 41, 1308, Society of Vacuum Coaters 505/
5 2004 Society of Vacuum Coaters 505/
Permeation Measurement Testing Techniques. Michelle Stevens MOCON, Inc.
Permeation Measurement Testing Techniques Michelle Stevens MOCON, Inc. Permeation Permeation Permeation is simply the flux of molecules through a material normalized to the pressure drop across the film.
More informationReliable, fast and accurate WVTR measurement technology. Dr. Jörg Koch SEMPA SYSTEMS GmbH
Reliable, fast and accurate WVTR measurement technology Dr. Jörg Koch SEMPA SYSTEMS GmbH INTRODUCTION Starting point Food industry Pharmaceutical industry Anorganic solar cells Organic solar cells Vacuum
More information6.5 Optical-Coating-Deposition Technologies
92 Chapter 6 6.5 Optical-Coating-Deposition Technologies The coating process takes place in an evaporation chamber with a fully controlled system for the specified requirements. Typical systems are depicted
More informationLecture 4. Ultrahigh Vacuum Science and Technology
Lecture 4 Ultrahigh Vacuum Science and Technology Why do we need UHV? 1 Atmosphere = 760 torr; 1 torr = 133 Pa; N ~ 2.5 10 19 molecules/cm 3 Hertz-Knudsen equation p ZW 1/ 2 ( 2mk T) At p = 10-6 Torr it
More informationDEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD
Chapter 4 DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD 4.1 INTRODUCTION Sputter deposition process is another old technique being used in modern semiconductor industries. Sputtering
More informationSecondary ion mass spectrometry (SIMS)
Secondary ion mass spectrometry (SIMS) ELEC-L3211 Postgraduate Course in Micro and Nanosciences Department of Micro and Nanosciences Personal motivation and experience on SIMS Offers the possibility to
More informationApplication of the GD-Profiler 2 to the PV domain
Application of the GD-Profiler 2 to the PV domain GD Profiler 2 RF GDOES permits to follow the distribution of the elements as function of depth. This is an ultra fast characterisation technique capable
More informationSEPARATION BY BARRIER
SEPARATION BY BARRIER SEPARATION BY BARRIER Phase 1 Feed Barrier Phase 2 Separation by barrier uses a barrier which restricts and/or enhances the movement of certain chemical species with respect to other
More informationHiBarSens: Tunable diode laser spectroscopy for ultra barrier measurement
HiBarSens: Tunable diode laser sectroscoy for ultra barrier measurement AIMCAL Web Coating & Handling Conference 2012 October 23, 2012 Myrtle Beach / USA Harald Beese, Fraunhofer IWS Dresden, Germany Fraunhofer
More informationGeneration of vacuum (pumps) and measurements
Generation of vacuum (pumps) and measurements Generation of vacuum (pumps): ᴥ pumping systems general considerations on their use and match with physical quantities introduced for the dimensioning of vacuum
More informationVacuum. Kai Schwarzwälder, Institut für Physik Universität Basel October 6 th 2006
Physics,, Technology and Techniques of the Vacuum Kai Schwarzwälder, Institut für Physik Universität Basel October 6 th 2006 Outline Introduction and basics Defintion of Vacuum Vacuum A vacuum is a volume
More informationInfluence of water on the total heat transfer in evacuated insulations
Bavarian Center for Applied Energy Research Influence of water on the total heat transfer in evacuated insulations Ulrich Heinemann ZAE Bayern, Würzburg, Germany ulrich.heinemann@zae.uni-wuerzburg.de 7
More informationSputter Ion Pump (Ion Pump) By Biswajit
Sputter Ion Pump (Ion Pump) By Biswajit 08-07-17 Sputter Ion Pump (Ion Pump) An ion pump is a type of vacuum pump capable of reaching pressures as low as 10 11 mbar under ideal conditions. An ion pump
More informationION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager
ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators Mauro Audi, Academic, Government & Research Marketing Manager ION Pumps Agilent Technologies 1957-59 Varian Associates invents the first
More information( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation
( KS A 3014-91 ) (1), standard reference conditions for gases 0, 101325 Pa (1 =760mmHg ), vacuum, low ( rough ) vacuum 100Pa, medium vacuum 100 01 Pa, high vacuum 01 10 5 Pa, ultra high vacuum ( UHV )
More informationPredicting the Lifetime of Flexible Permeation Barrier Layers for OLED Displays
Predicting the Lifetime of Flexible Permeation Barrier Layers for OLED Displays Bhadri Visweswaran, Siddharth Harikrishna Mohan, William Quinn, Ruiqing (Ray) Ma, Jeff Silvernail, James Sturm, Sigurd Wagner
More informationHiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis
Technical Specifications The IGA-1 is designed for gravimetric mixed gas sorption, as well as single component vapor sorption analysis, and powerfully combines the features of the IGA-1, IGA-2 and IGA-3.
More informationAutoresonant Ion Trap Mass Spectrometer The RGA Alternative
Autoresonant Ion Trap Mass Spectrometer The GA Alternative 1 What is a Mass Spectrometer? Ionizer Mass Spectrometer Mass Separator Magnetic Sector, Quadrupole or Ion Trap Detector Partial Pressure Measurement
More informationRepetition: Physical Deposition Processes
Repetition: Physical Deposition Processes PVD (Physical Vapour Deposition) Evaporation Sputtering Diode-system Triode-system Magnetron-system ("balanced/unbalanced") Ion beam-system Ionplating DC-glow-discharge
More informationAdsorption boundary curve influenced by step interval of relative humidity investigated by Dynamic Vapour Sorption equipment
IRG/WP 11-40547 THE INTERNATIONAL RESEARCH GROUP ON WOOD PROTECTION Section 4 Processes and Properties Adsorption boundary curve influenced by step interval of relative humidity investigated by Dynamic
More informationKeywords. 1=magnetron sputtering, 2= rotatable cathodes, 3=substrate temperature, 4=anode. Abstract
Managing Anode Effects and Substrate Heating from Rotatable Sputter Targets. F. Papa*, V. Bellido-Gonzalez**, Alex Azzopardi**, Dr. Dermot Monaghan**, *Gencoa Technical & Business Support in US, Davis,
More informationChemistry Instrumental Analysis Lecture 34. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 34 From molecular to elemental analysis there are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry
More informationA novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS)
IOP Conference Series: Materials Science and Engineering A novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS) To cite this article: D A L Loch and A P Ehiasarian 2012 IOP Conf. Ser.:
More informationOxygen Permeation Through FEP Teflon and Kapton Polyimide
Oxygen Permeation Through FEP Teflon and Kapton Polyimide SUMMARY The presence of oxygen in a gas sample causes a significantly different flame ionization detector (FID) response to hydrocarbons from that
More informationCreating New Barriers with Graphene
Creating New Barriers with Graphene Authors: Richard Akam, Lynn Chikosha & Tim von Werne Introduction Graphene was first isolated in 2004 by Andre Geim and Konstantin Novoselov at Manchester University.
More informationUltra-High Vacuum Technology. Sputter Ion Pumps l/s
Ultra-High Vacuum Technology 30-400 l/s 181.06.01 Excerpt from the Product Chapter C15 Edition November 2007 Contents General General..........................................................................
More information3. Experimental Methods and Instrumentation.
3. Experimental Methods and Instrumentation. 3.1 UHV Setup An ultrahigh vacuum chamber pumped by a turbo molecular pump with a base pressure in the low 10-10 mbar range was used (figure 3.1). This chamber
More informationMeasurement of wettability for polymer materials using non-contact surface resistivity
Proc. 26 Electrostatics Joint Conference Measurement of wettability for polymer materials using non-contact surface resistivity tester Toshiyuki Sugimoto, Takuya Aoki Graduate school of Science and Engineering
More informationLecture 5-8 Instrumentation
Lecture 5-8 Instrumentation Requirements 1. Vacuum Mean Free Path Contamination Sticking probability UHV Materials Strength Stability Permeation Design considerations Pumping speed Virtual leaks Leaking
More informationJARA FIT Ferienprakticum Nanoelektronik Experiment: Resonant tunneling in quantum structures
JARA FIT Ferienprakticum Nanoelektronik 2013 Experiment: Resonant tunneling in quantum structures Dr. Mihail Ion Lepsa, Peter Grünberg Institut (PGI 9), Forschungszentrum Jülich GmbH 1. Introduction The
More informationRelative Sensitivity RS Measurements of Gases
Gas Analysis Relative Sensitivity RS Measurements of Gases Introduction This note describes the main factors that influence the relative sensitivity factor (RSF) of a mass spectrometer and describes how
More informationLecture 22 Ion Beam Techniques
Lecture 22 Ion Beam Techniques Schroder: Chapter 11.3 1/44 Announcements Homework 6/6: Will be online on later today. Due Wednesday June 6th at 10:00am. I will return it at the final exam (14 th June).
More informationGeneration of vacuum (pumps): Vacuum (pressure) measurements:
Generation of vacuum (pumps) p and measurements Generation of vacuum (pumps): ᴥ pumping p systems general considerations on their use and match with physical quantities introduced for the dimensioning
More informationResearch and Development of Parylene Thin-Film Deposition and Application for Water-Proofing
Advanced Materials Research Online: 2012-06-14 ISSN: 1662-8985, Vols. 538-541, pp 23-28 doi:10.4028/www.scientific.net/amr.538-541.23 2012 Trans Tech Publications, Switzerland Research and Development
More informationPortfolio. Chemical supply. systems. Bulk and. special gas distribution. Engineering, design and development. Service and operation
Thin Film Solutions Portfolio Chemical supply Bulk and systems special gas distribution Engineering, design and development Service and operation Process vacuum and exhaust systems 01-2010 Global Structure
More informationPHYSICAL AND CHEMICAL PROPERTIES OF ATMOSPHERIC PRESSURE PLASMA POLYMER FILMS
PHYSICAL AND CHEMICAL PROPERTIES OF ATMOSPHERIC PRESSURE PLASMA POLYMER FILMS O. Goossens, D. Vangeneugden, S. Paulussen and E. Dekempeneer VITO Flemish Institute for Technological Research, Boeretang
More informationVacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular
Vacuum Technology Vacuum Pumps Two general classes exist: Gas transfer physical removal of matter Mechanical, diffusion, turbomolecular Adsorption entrapment of matter Cryo, sublimation, ion Mechanical
More informationDEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING SRM NAGAR, KATTANKULATHUR-603203 EI 2302 ANALYTICAL INSTRUMENTS QUESTION BANK UNIT I COLORIMETRY AND SPECTROPHOTOMETRY Part A 1. State Lambert
More informationChap. 19 Miscellaneous Detectors
Chap. 19 Miscellaneous Detectors Up to this point: Gas-filled detectors ion chambers, proportional counters, GM counters Scintillators organic, inorganic Semiconductor-based detectors Si or Ge Other possibilities:
More informationSecondary Ion Mass Spectroscopy (SIMS)
Secondary Ion Mass Spectroscopy (SIMS) Analyzing Inorganic Solids * = under special conditions ** = semiconductors only + = limited number of elements or groups Analyzing Organic Solids * = under special
More informationLecture 3 Vacuum Science and Technology
Lecture 3 Vacuum Science and Technology Chapter 3 - Wolf and Tauber 1/56 Announcements Homework will be online from noon today. This is homework 1 of 4. 25 available marks (distributed as shown). This
More informationAn Introduction to Auger Electron Spectroscopy
An Introduction to Auger Electron Spectroscopy Spyros Diplas MENA3100 SINTEF Materials & Chemistry, Department of Materials Physics & Centre of Materials Science and Nanotechnology, Department of Chemistry,
More informationEarlier Lecture. In the earlier lecture, we have seen non metallic sensors like Silicon diode, Cernox and Ruthenium Oxide.
41 1 Earlier Lecture In the earlier lecture, we have seen non metallic sensors like Silicon diode, Cernox and Ruthenium Oxide. Silicon diodes have negligible i 2 R losses. Cernox RTDs offer high response
More informationKinetic Molecular Theory. 1. What are the postulates of the kinetic molecular theory?
Kinetic Molecular Theory 1. What are the postulates of the kinetic molecular theory? *These postulates are particularly problematic when it comes to extending this theory to real gases. Regardless of how
More informationCHM2045 Exam 3 Review Fall 2015
The steps to solving any chemistry problem 1) Read Question 2) Re-read Question 3) Write down everything you are given 4) Write down what you are trying to find CHM2045 Exam 3 Review 1) Write out the following
More informationThermal Conductivity of VIPs as a Function of Internal Pressure
Thermal Conductivity of VIPs as a Function of Internal Pressure The insulation properties of a VIP panel are determined by its effective thermal conductivity, as described in Eq.1. The lower the thermal
More informationSecondary Ion Mass Spectrometry (SIMS) Thomas Sky
1 Secondary Ion Mass Spectrometry (SIMS) Thomas Sky Depth (µm) 2 Characterization of solar cells 0,0 1E16 1E17 1E18 1E19 1E20 0,2 0,4 0,6 0,8 1,0 1,2 P Concentration (cm -3 ) Characterization Optimization
More informationNew Methods for Measuring Water Desorption and Vapour Permeation Rates in Membranes
New Methods for Measuring Water Desorption and Vapour Permeation Rates in Membranes L. I. iortea, D. O Driscoll, E. P. Berg, P. Xiao, F.. Pascut and R. E. Imhof School of Engineering, South Bank University,
More informationMOLECULAR SURFACE PUMPING: CRYOPUMPING
51 MOLECULAR SURFACE PUMPING: CRYOPUMPING C. Benvenuti CERN, Geneva, Switzerland Abstract Weak van der Waals attractive forces may provide molecular gas pumping on surfaces cooled at sufficiently low temperatures.
More informationStudying Metal to Insulator Transitions in Solids using Synchrotron Radiation-based Spectroscopies.
PY482 Lecture. February 28 th, 2013 Studying Metal to Insulator Transitions in Solids using Synchrotron Radiation-based Spectroscopies. Kevin E. Smith Department of Physics Department of Chemistry Division
More informationMethods of surface analysis
Methods of surface analysis Nanomaterials characterisation I RNDr. Věra Vodičková, PhD. Surface of solid matter: last monoatomic layer + absorbed monolayer physical properties are effected (crystal lattice
More informationVacuum techniques (down to 1 K)
Vacuum techniques (down to 1 K) For isolation (deep Knudsen regime) liquid helium dewar / inner vacuum jacket Leak testing at level 10-11 Pa m3/s (10-10 mbar l/s) liquid helium dewar & transfer syphon
More information(Total for Question = 5 marks) PhysicsAndMathsTutor.com
1 Rutherford designed an experiment to see what happened when alpha particles were directed at a piece of gold foil. Summarise the observations and state the conclusions Rutherford reached about the structure
More informationTechniques for Fast Measurements of Low Dewpoint in Portable Hygrometers
Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers Speaker / Author: Nick Malby, Michell Instruments Ltd, 48 Lancaster Way Business Park, Ely, Cambridgeshire. CB6 3NW. UK. +44 1353
More informationDeuterium Gas Analysis by Residual Gas Analyzer
Journal of Physics: Conference Series Deuterium Gas Analysis by Residual Gas Analyzer To cite this article: B K Das et al 2012 J. Phys.: Conf. Ser. 390 012009 View the article online for updates and enhancements.
More informationCatalysis CAPABILITIES
Catalysis www.extrel.com CAPABILITIES Contents Extrel instruments have been recognized for their exceptional performance by the world s leading researchers for more than 50 years. Reliability and flexibility
More informationExtrel Application Note
Extrel Application Note Real-Time Plasma Monitoring and Detection of Trace H 2 O and HF Species in an Argon Based Plasma Jian Wei, 575 Epsilon Drive, Pittsburgh, PA 15238. (Presented at the 191st Electrochemical
More informationDistillation purification and radon assay of liquid xenon
Distillation purification and radon assay of liquid xenon Yasuo Takeuchi Kamioka Observatory, ICRR, Univ. of Tokyo, Kamioka-cho, Hida-shi, Gifu 56-125, Japan Abstract. We succeeded to reduce the Kr contamination
More information2.B Laser Ionization of Noble Gases by Coulomb Barrier Suppression
ADVANCED TECHNOLOGY DEVELOPMENTS 2.B Laser Ionization of Noble Gases by Coulomb Barrier Suppression Introduction The ionization of atoms and ions in high-intensity laser fields allows a study of atomic
More informationLecture 1: Vapour Growth Techniques
PH3EC2 Vapour Growth and Epitaxial Growth Lecturer: Dr. Shinoj V K Lecture 1: Vapour Growth Techniques 1.1 Vapour growth The growth of single crystal materials from the vapour phase. Deposition from the
More informationIntroduction to the Q Trap LC/MS/MS System
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment ABI Q Trap LC/MS/MS Introduction to the Q Trap LC/MS/MS System The Q Trap
More informationVacuum II. G. Franchetti CAS - Bilbao. 30/5/2011 G. Franchetti 1
Vacuum II G. Franchetti CAS Bilbao 30/5/2011 G. Franchetti 1 Index Creating Vacuum (continuation) Measuring Vacuum Partial Pressure Measurements 30/5/2011 G. Franchetti 2 Laminar flow Cold surface Diffusion
More informationThe Vacuum Sorption Solution
The Total Sorption Solution The Vacuum Sorption Solution The Vacuum Sorption Solution www.thesorptionsolution.com About the Technique DVS Vacuum - the only gravimetric system that supports static and dynamic
More informationLow Temperature (LT), Ultra High Vacuum (UHV LT) Scanning Probe Microscopy (SPM) Laboratory
Low Temperature (LT), Ultra High Vacuum (UHV LT) Scanning Probe Microscopy (SPM) Laboratory The laboratory of Low Temperature, Ultra High Vacuum (UHV LT) is specifically designed for surface science microscopy
More informationAquaFlux A New Instrument for Water Vapour Flux Density Measurement
AquaFlux A New Instrument for Water Vapour Flux Density Measurement E. P. Berg, F.. Pascut, L. I. iortea, D. O Driscoll, P. Xiao, and R. E. Imhof chool of Engineering, outh Bank University, 103 Borough
More informationNova 600 NanoLab Dual beam Focused Ion Beam IITKanpur
Nova 600 NanoLab Dual beam Focused Ion Beam system @ IITKanpur Dual Beam Nova 600 Nano Lab From FEI company (Dual Beam = SEM + FIB) SEM: The Electron Beam for SEM Field Emission Electron Gun Energy : 500
More informationStatus of the magnetic spectrometer PRISMA
Status of the magnetic spectrometer PRISMA E. Fioretto INFN Laboratori Nazionali di Legnaro 1 PRISMA in vacuum mode Dipole 50 cm 120 cm 60 +130 Quadrupole 30 cm Beam Target 2-20 Rotating platform PRISMA:
More informationX-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu
X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu X-ray Photoelectron Spectroscopy Introduction Qualitative analysis Quantitative analysis Charging compensation Small area analysis and XPS imaging
More informationAdvanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7
Advanced Lab Course X-Ray Photoelectron Spectroscopy M210 As of: 2015-04-01 Aim: Chemical analysis of surfaces. Content 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT 3 3.1 Qualitative analysis 6 3.2 Chemical
More informationSupplementary Figure 1 In-situ and ex-situ XRD. a) Schematic of the synchrotron
Supplementary Figure 1 In-situ and ex-situ XRD. a) Schematic of the synchrotron based XRD experimental set up for θ-2θ measurements. b) Full in-situ scan of spot deposited film for 800 sec at 325 o C source
More informationCase study: molecular dynamics of solvent diffusion in polymers
Course MP3 Lecture 11 29/11/2006 Case study: molecular dynamics of solvent diffusion in polymers A real-life research example to illustrate the use of molecular dynamics Dr James Elliott 11.1 Research
More informationModelling of the Target Voltage Behaviour in Reactive Sputtering R. De Gryse*, D. Depla University Ghent, Krijgslaan 281/S1, B-9000 GENT, Belgium
Modelling of the Target Voltage Behaviour in Reactive Sputtering R. De Gryse*, D. Depla University Ghent, Krijgslaan 28/S, B-9 GENT, Belgium Abstract It has been shown that at least two mechanisms are
More informationAlchemy Science: Herbal Tinctures
Alchemy Science: Herbal Tinctures THLady Medb ingen Echuid email: daisy@daisyviktoria.com website: polkadotpanther.com Quick Intro A tincture is an infusion, known in modern day process engineering as
More informationTHE REAL MEANING OF THE HUBBLE DIAGRAM
THE REAL MEANING OF THE HUBBLE DIAGRAM KARAN R.TAKKHI Pune 411015, India E-mail: karantakkhi007@gmail.com ABSTRACT The Hubble diagram continues to remain one of the most important graphical representations
More informationElectronics Supplementary Information for. Manab Kundu, Cheuk Chi Albert Ng, Dmitri Y. Petrovykh and Lifeng Liu*
Electronics Supplementary Information for Nickel foam supported mesoporous MnO 2 nanosheet arrays with superior lithium storage performance Manab Kundu, Cheuk Chi Albert Ng, Dmitri Y. Petrovykh and Lifeng
More informationEtching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity
Etching Issues - Anisotropy Dry Etching Dr. Bruce K. Gale Fundamentals of Micromachining BIOEN 6421 EL EN 5221 and 6221 ME EN 5960 and 6960 Isotropic etchants etch at the same rate in every direction mask
More informationRole of Electrochemical Reactions in the Degradation Mechanisms of AlGaN/GaN HEMTs
Role of Electrochemical Reactions in the Degradation Mechanisms of AlGaN/GaN HEMTs Feng Gao 1,2, Bin Lu 2, Carl V. Thompson 1, Jesús del Alamo 2, Tomás Palacios 2 1. Department of Materials Science and
More information1 (a) Define magnetic flux [1]
1 (a) Define magnetic flux..... [1] (b) Fig. 4.1 shows a generator coil of 5 turns and cross-sectional area 2.5 1 3 m 2 placed in a magnetic field of magnetic flux density.35 T. The plane of the coil is
More informationDYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.
DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS. www.hidenisochema.com The IGAsorp is a fully automated compact bench-top DVS
More informationModern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods
Modern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods Methods for catalyst preparation Methods discussed in this lecture Physical vapour deposition - PLD
More informationmcdonald (pam78654) HW 4B: Gases and Kinetics laude (89560) 1
mcdonald (pam78654) HW 4B: Gases and Kinetics laude (89560) 1 This print-out should have 20 questions. Multiple-choice questions may continue on the next column or page find all choices before answering.
More informationAuthor(s) Isozumi, Yasuhito; Takahashi, Norit. Citation University (1992), 69(5-6):
Detection Efficiency of Position-Se TitleCounter for Low (100-1000 ev) and H X Rays Author(s) Isozumi, Yasuhito; Takahashi, Norit Citation Bulletin of the Institute for Chemi University (1992), 69(5-6):
More informationAN EXPERIMENTAL STUDY OF THE FROST FORMATION ON A COLD SURFACE IN FREE CONVECTIVE FLOW
AN EXPERIMENTAL STUDY OF THE FROST FORMATION ON A COLD SURFACE IN FREE CONVECTIVE FLOW Giovanni Tanda, Marco Fossa DITEC, Università degli Studi di Genova via all Opera Pia 15a, I-16145 Genova, ITALY E-mail:
More informationvapors: gases of substances that are normally liquids or solids 1 atm = 760 mm Hg = 760 torr = kpa = bar
Gases A Chemistry Lecture Outline Name: Basics on Gases composition of the atmosphere: properties of gases: vapors: gases of substances that are normally liquids or solids Equation for pressure: 1 atm
More informationTable 1: Residence time (τ) in seconds for adsorbed molecules
1 Surfaces We got our first hint of the importance of surface processes in the mass spectrum of a high vacuum environment. The spectrum was dominated by water and carbon monoxide, species that represent
More informationEQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar
Modern Physics Laboratory Beta Spectroscopy Experiment In this experiment, electrons emitted as a result of the radioactive beta decay of Cs-137 are measured as a function of their momentum by deflecting
More informationUNIT 3. By: Ajay Kumar Gautam Asst. Prof. Dev Bhoomi Institute of Technology & Engineering, Dehradun
UNIT 3 By: Ajay Kumar Gautam Asst. Prof. Dev Bhoomi Institute of Technology & Engineering, Dehradun 1 Syllabus Lithography: photolithography and pattern transfer, Optical and non optical lithography, electron,
More informationFundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics
Mass spectrometry (MS) is the technique for protein identification and analysis by production of charged molecular species in vacuum, and their separation by magnetic and electric fields based on mass
More informationVariations of Chemical Composition and Band Gap Energies in Hectorite and Montmorillonite Clay Minerals on Sub-Micron Length Scales
2006-2011 Mission Kearney Foundation of Soil Science: Understanding and Managing Soil-Ecosystem Functions Across Spatial and Temporal Scales Final Report: 2009008, 1/1/2011-12/31/2011 Variations of Chemical
More informationLECTURE 5 SUMMARY OF KEY IDEAS
LECTURE 5 SUMMARY OF KEY IDEAS Etching is a processing step following lithography: it transfers a circuit image from the photoresist to materials form which devices are made or to hard masking or sacrificial
More informationReal-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)
Real-Time Detection: 1953 From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953) Sampling Gases and Vapors Gas: A state of matter characterized by very low density and
More informationTPD-MS. Photocatalytic Studies Using Temperature Programmed Desorption Mass Spectrometry (TPD-MS) APPLICATION NOTE NOTE
TPD-MS APPLICATION NOTE NOTE Photocatalytic Studies Using Temperature Programmed Desorption Mass Spectrometry (TPD-MS) Thermal analysis consists of many techniques for the exploration of the physical properties
More informationv = E B FXA 2008 UNIT G485 Module Magnetic Fields BQv = EQ THE MASS SPECTROMETER
UNIT G485 Module 1 5.1.2 Magnetic Fields 11 Thus, in order for the particle to suffer NO DEFLECTION and so exit the device at Y : From which : MAGNETIC FORCE UP = ELECTRIC FORCE DOWN BQv = EQ THE MASS
More information(Refer Slide Time 00:09) (Refer Slide Time 00:13)
(Refer Slide Time 00:09) Mass Spectrometry Based Proteomics Professor Sanjeeva Srivastava Department of Biosciences and Bioengineering Indian Institute of Technology, Bombay Mod 02 Lecture Number 09 (Refer
More informationSUPPLEMENTARY INFORMATION
DOI: 1.138/NNANO.11.142 Experimental Demonstration of a Single-Molecule Electric Motor Heather L. Tierney, Colin J. Murphy, April D. Jewell, Ashleigh E. Baber, Erin V. Iski, Harout Y. Khodaverdian, Allister
More informationTHIN FLEXIBLE POLYMER SUBSTRATES COATED BY THICK FILMS IN ROLL-TO-ROLL VACUUM
ARCOTRONICS INDUSTRIES SpA Via San Lorenzo, 19 40037 Sasso Marconi (BO) Italy Tel. (+39) 051939111 Fax (+39) 051840684 http://www.arcotronics.com THIN FLEXIBLE POLYMER SUBSTRATES COATED BY THICK FILMS
More informationIntroduction to Photolithography
http://www.ichaus.de/news/72 Introduction to Photolithography Photolithography The following slides present an outline of the process by which integrated circuits are made, of which photolithography is
More informationCandidate Name Centre Number Candidate Number. The Language of Chemistry, Structure of Matter and Simple Reactions
AS CHEMISTRY Specimen Assessment Materials 5 Candidate Name Centre Number Candidate Number AS CHEMISTRY COMPONENT 1 The Language of Chemistry, Structure of Matter and Simple Reactions SPECIMEN PAPER 1
More informationGeneric Detector. Layers of Detector Systems around Collision Point
Generic Detector Layers of Detector Systems around Collision Point Tracking Detectors Observe particle trajectories in space with as little disturbance as possible 2 use a thin ( gm. cm ) detector Scintillators
More informationIndustrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology - Kharagpur
Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology - Kharagpur Lecture - 19 Low Pressure Measurement Welcome to the lesson 19 of Industrial Instrumentation.
More information