Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)

Size: px
Start display at page:

Download "Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb)"

Transcription

1 Test Report No. CE/2017/40923 Date 2017/04/14 Page 1 of 5 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Sample Receiving Date Testing Period ELEKTRISOLA COPPER BARE WIRE (Cu) 2017/04/ /04/07 TO 2017/04/14 ============================================================================================ Test Result(s) Please refer to next page(s). This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http// and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http// Attention is

2 Test Report No. CE/2017/40923 Date 2017/04/14 Page 2 of 5 Test Result(s) PART NAME No.1 COPPER COLORED METAL WIRE Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI)(#2) Beryllium (Be) Unit µg/cm² Method With reference to IEC (2013) and With reference to IEC (2013) and With reference to IEC (2013) and With reference to IEC (2015) and performed by UV-VIS. With reference to US EPA 3050B (1996). Analysis was Result MDL No n.d. Note 1. = ppm;0.1wt% = 1000ppm 2. MDL = Method Detection Limit 3. n.d. = Not Detected = less than MDL 4. (#2) = a. The sample is positive for Cr(VI) if the Cr(VI) concentration is greater than 0.13 µg/cm². The sample coating is considered to contain Cr(VI) b. The sample is negative for Cr(VI) if Cr(VI) is n.d. (concentration less than 0.10 µg/cm²). The coating is considered a non-cr(vi) based coating c. The result between 0.10 µg/cm² and 0.13 µg/cm² is considered to be inconclusive - unavoidable coating variations may influence the determination. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http// and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http// Attention is

3 Test Report No. CE/2017/40923 Date 2017/04/14 Page 3 of 5 #FLOW Analytical flow chart of Heavy Metal These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr 6+ test method excluded) Technician JR Wang Supervisor Troy Chang Cutting / Preparation Sample Measurement Pb Cd Acid digestion by suitable acid depended on different sample material (as below table) Hg Microwave digestion with HNO 3 /HCl/HF Cr 6+ (Note**) Add appropriate amount of digestion reagent Filtration Heat to appropriate temperature to extract Solution ICP-AES Residue 1) Alkali Fusion 2) HCl to dissolve Sample Material Digestion Acid Steel, copper, aluminum, solder Aqua regia, HNO 3, HCl, HF, H 2 O 2 Glass HNO 3 /HF Gold, platinum, palladium, ceramic Aqua regia Silver HNO 3 Plastic H 2 SO 4, H 2 O 2, HNO 3, HCl Others Added appropriate reagent to total digestion Cool, filter digestate through filter Add diphenyl-carbazide for color development measure the absorbance at 540 nm by UV-VIS Note** (For IEC 62321) (1) For non-metallic material, add alkaline digestion reagent and heat to 90~95. (2) For metallic material, add pure water and heat to boiling. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http// and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http// Attention is

4 Test Report No. CE/2017/40923 Date 2017/04/14 Page 4 of 5 These samples were dissolved totally by pre-conditioning method according to below flow chart. Technician JR Wang Supervisor Troy Chang Flow Chart of digestion for the elements analysis performed by ICP-AES Cutting / Preparation Sample Measurement Acid digestion by suitable acid depended on different sample material (as below table) Filtration Solution Residue 1) Alkali Fusion 2) HCl to dissolve ICP-AES Steel, copper, aluminum, solder Aqua regia, HNO 3, HCl, HF, H 2 O 2 Glass HNO 3 /HF Gold, platinum, palladium, ceramic Aqua regia Silver HNO 3 Plastic H 2 SO 4, H 2 O 2, HNO 3, HCl Others Added appropriate reagent to total digestion This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http// and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http// Attention is

5 Test Report No. CE/2017/40923 Date 2017/04/14 Page 5 of 5 #PIC * The tested sample / part is marked by an arrow if it's shown on the photo. * ** End of Report ** This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http// and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http// Attention is

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/ Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period FLUX SR-34SUPER

More information

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI No. CE/2014/51910 Date 2014/05/20 Page 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info.

More information

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He Test Report No. CE/2016/43515 Date 2016/04/22 Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Color Style/Item

More information

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item Test Report No. CE/2015/C2965A Date 2016/02/16 Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No.

More information

No. CE/2015/90157 Date 2015/09/04 Page 2 of 5 Test Result(s) PART NAME No.1 GREEN INK Antimony (Sb) Test Item(s) Halogen-Chlorine (Cl) (CAS No

No. CE/2015/90157 Date 2015/09/04 Page 2 of 5 Test Result(s) PART NAME No.1 GREEN INK Antimony (Sb) Test Item(s) Halogen-Chlorine (Cl) (CAS No No. CE/2015/90157 Date 2015/09/04 Page 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Color Sample Receiving Date

More information

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs Page 1 of 8 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period DIE BONDING

More information

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI No. CE/2012/C1503 Date 2012/12/18 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Buyer/Order No. Other Info. Sample Receiving Date

More information

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Style/Item No. Sample Receiving

More information

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With Page 1 of 11 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Sample Receiving Date Testing Period AL (5052) X HPL X COPPER

More information

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs Page 1 of 9 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ADHESIVE

More information

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI No. KE/2016/52417 Date 2016/05/26 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Style/Item No. Material Component Color Sample Receiving

More information

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11 No. CE/2012/A3090 Date 2012/10/23 Page 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Buyer/Order No. Other Info. Sample Receiving Date

More information

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ELEKTRISOLA

More information

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Color : Sample Receiving Date

More information

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen No. CE/2012/44922 Date 2012/05/03 Page 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as Sample Description Style/Item No. Sample Receiving Date Testing Period

More information

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7 Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving

More information

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06 Page: 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Color : Sample Receiving Date : Testing Period : Sample Submitted

More information

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of Page 1 of 11 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF 6592LV

More information

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s). Test Report No. : CE/2007/C7382B Date : 2008/06/18 Page : 1 of 5 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Manufacturer

More information

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf Date of issue August 19, 2015 Management number 00000000152298 TO AMKOR TECHNOLOGY Analysis Report Analysis Compounds RoHS(Cd,Pb,Cr.Hg,PBB,PBDE) 1.Parts number ELP NBD-5232K 2.Results of analysis Please

More information

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He Test Report No. CE/2017/62572 Date 2017/06/19 Page 1 of 7 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No.

More information

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc Page 1 of 11 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info. Sample Receiving Date Testing Period

More information

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe Page 1 of 9 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF-6522

More information

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving

More information

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : JP Reference

More information

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite Test Report No. CE/2014/43454A Date 2014/04/23 Page 1 of 11 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item

More information

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Lot No. : Material Component

More information

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : JP Reference

More information

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of Page 1 of 10 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period TSF 6502JCR

More information

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving

More information

Page 2 of 10 Test Result(s) PART NAME No.1 MIXED BLACK AND WHITE PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (

Page 2 of 10 Test Result(s) PART NAME No.1 MIXED BLACK AND WHITE PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC ( Page 1 of 10 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info. Sample Receiving Date Testing Period

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf Page 1 of 10 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Buyer/Order No. Other Info. Sample Receiving Date Testing Period

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Sample Receiving Date Testing Period ELEKTRISOLA

More information

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item

More information

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 1 of 14 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item

More information

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe Page : 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving Date Testing Period : : : : SMD CRYSTAL RESONATOR

More information

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Color Sample Receiving Date Testing Period Sample Submitted By

More information

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Page 1 of 12 The following samples was/were submitted and identified by/on behalf of the applicant as Sample Submitted By Sample Description Style/Item No. Buyer/Order No. Other Info. Sample Receiving

More information

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Color :

More information

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change Bourns Manufacturers Representatives Corporate Distributor Product Managers Americas Sales Team Asia Sales Team Europe Sales Team Bourns Internal Bourns Plant Managers June, 2010 RESISTOR NETWORKS Thin

More information

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 1 of 12 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving

More information

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10 Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : FPC HOUSING Style/Item No.

More information

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 1 of 11 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Lot No.

More information

Chemical Laboratory - Kao., Page 2 of 13 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Page 2 of 13 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r Chemical Laboratory - Kao., Page 1 of 13 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period

More information

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period

More information

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT Test Report No. HLL13/1269/2441 Date: August 22, 2013 Page 1 of 6 CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT LO LA2, DUONG SO 1, KCN XUYEN A, MY HANH BAC, DUC HOA, LONG AN. VIET

More information

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period

More information

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r Chemical Laboratory - Kao., Page 1 of 14 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Sample Receiving Date Testing Period

More information

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer Test Report No. KE/2017/C1499 Date 2018/01/02 Page 1 of 7 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Material Component

More information

Page : 2 of 20 Test Result(s) PART NAME No.1 : SILVER COLORED METAL WIRE (INCLUDING THE PLATING LAYER) Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method

Page : 2 of 20 Test Result(s) PART NAME No.1 : SILVER COLORED METAL WIRE (INCLUDING THE PLATING LAYER) Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method Page : 1 of 20 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Description Style/Item No. Sample Receiving Date Testing Period : : : : NIPPON COPPER WIRE

More information

Chemical Laboratory - Kao., Page : 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) :

Chemical Laboratory - Kao., Page : 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) : Chemical Laboratory - Kao., Page : 1 of 18 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Description Color Sample Receiving Date Testing Period Sample

More information

Test Report No: (2) Date: 24-Jun-2014 Page 1 of 5

Test Report No: (2) Date: 24-Jun-2014 Page 1 of 5 Test Report No: 10339361(2) Date: 24-Jun-2014 Page 1 of 5 JSB Tech Pte Ltd 20 Science Park Road Teletech Park #02-03A Singapore Science Park 2 Singapore 117674 The following sample(s) was/were submitted

More information

Page : 2 of 19 Test Result(s) PART NAME No.1 : COPPER COLORED METAL SHEET (EXCLUDING THE FRAME) Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexav

Page : 2 of 19 Test Result(s) PART NAME No.1 : COPPER COLORED METAL SHEET (EXCLUDING THE FRAME) Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexav Page : 1 of 19 The following samples was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description SGS Korea File No. Style/Item No. Sample Material Sample

More information

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 1 of 8 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description

More information

Test Report No. : CE/2014/A2569 Date : 2014/10/22 Page : 2 of 20 Test Result(s) PART NAME No.1 : GOLDEN COLORED METAL WIRE Cadmium (Cd) Lead (Pb) Merc

Test Report No. : CE/2014/A2569 Date : 2014/10/22 Page : 2 of 20 Test Result(s) PART NAME No.1 : GOLDEN COLORED METAL WIRE Cadmium (Cd) Lead (Pb) Merc Test Report No. : CE/2014/A2569 Date : 2014/10/22 Page : 1 of 20 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Submitted By Sample Description Style/Item

More information

Chemical Laboratory - Kao., Page 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) ( )

Chemical Laboratory - Kao., Page 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) ( ) Chemical Laboratory - Kao., Page 1 of 18 The following sample(s) was/were submitted and identified by/on behalf of the applicant as Sample Description Style/Item No. Color Sample Receiving Date Testing

More information

Chemical Laboratory - Kao., Page : 2 of 18 Test Result(s) PART NAME No.1 : Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI)

Chemical Laboratory - Kao., Page : 2 of 18 Test Result(s) PART NAME No.1 : Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Chemical Laboratory - Kao., Page : 1 of 18 The following sample(s) was/were submitted and identified by/on behalf of the applicant as : Sample Description Sample Receiving Date Testing Period Sample Submitted

More information

No. :KA/2009/21839 Date: 2009/02/27 Page: 2 of 9 TEST PART DESCRIPTION: NO.1 : NATURAL POLYPROPYLENE IMPACT COPOLYMER Test Item (s): Anthracene (CAS N

No. :KA/2009/21839 Date: 2009/02/27 Page: 2 of 9 TEST PART DESCRIPTION: NO.1 : NATURAL POLYPROPYLENE IMPACT COPOLYMER Test Item (s): Anthracene (CAS N No. :KA/2009/21839 Date: 2009/02/27 Page: 1 of 9 The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Description : Style/Item No. : Sample Receiving Date :

More information

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5 Test Report No: 10300974(1) R1 Date: 29-Apr-13 Page 1 of 5 JSB Tech Pte Ltd 20 Science Park Road Teletech Park #02-03A Singapore Science Park 2 Singapore 117674 THIS REPORT IS TO SUPERSEDE TEST REPORT

More information

Test Report. LEDELS LIGHTING CO., LTD Address. Applicant

Test Report. LEDELS LIGHTING CO., LTD Address. Applicant Test Report No. R011412010R-1 Date Dec. 09, 2014 Page 1 of 10 Applicant LEDELS LIGHTING CO., LTD Address 5F, Block C, Mingjinhai Ind. Park, Zhoushi Road, Shiyan, Bao an, Shenzhen, Guangdong, China The

More information

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014 RAJASTHAN ELECTRIC INDUSTRIES. C-2, INDUSTRIAL ESTATE BAIS GODAM JAIPUR- INDIA CONTACT PERSON : Mr. GAURANG GUPTA THE FOLLOWING SAMPLE(S) WAS/WERE SUBMITTED AND IDENTIFIED BY/ON BEHALF OF THE CUSTOMER

More information

3M OPTICAL SYSTEMS No. : CE/2007/13746 Page : 2 of 6 Test Result(s) PART NAME NO.1 : 3M OPTICAL FILM Test Item (s): Unit Method MDL Result Method No.1

3M OPTICAL SYSTEMS No. : CE/2007/13746 Page : 2 of 6 Test Result(s) PART NAME NO.1 : 3M OPTICAL FILM Test Item (s): Unit Method MDL Result Method No.1 3M OPTICAL SYSTEMS 3M CENTER, BUILDING 235-1E-54 ST. PAUL, MN 55144-1000 No. : CE/2007/13746 Date : 2007/01/22 Page : 1 of 6 The following sample(s) was/were submitted and identified by/on behalf of the

More information

PRODUCT/PROCESS CHANGE NOTICE (PCN)

PRODUCT/PROCESS CHANGE NOTICE (PCN) Integrated Device Technology, Inc. 6024 Silver Creek Valley Road, San Jose, CA - 95138 PRODUCT/PROCESS CHANGE NOTICE (PCN) PCN # A1208-06 Date November 16, 2012 MEANS OF DISTINGUISHING CHANGED DEVICES

More information

Test Report No. : CE/2011/A5289 Date : 2011/11/02 Page : 2 of 18 Test Result(s) PART NAME No.1 : BLACK GRAINS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Test Report No. : CE/2011/A5289 Date : 2011/11/02 Page : 2 of 18 Test Result(s) PART NAME No.1 : BLACK GRAINS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Test Report No. : CE/2011/A5289 Date : 2011/11/02 Page : 1 of 18 The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description Style/Item No. Buyer/Order No.

More information

Test Report No. CTSSA/22961(B)/12+KA/2012/A1244 Date : 19/11/2012 Page: 1 of 13 CTS Ref. CTSSA/12/3702/Tanaka

Test Report No. CTSSA/22961(B)/12+KA/2012/A1244 Date : 19/11/2012 Page: 1 of 13 CTS Ref. CTSSA/12/3702/Tanaka Test Report No. CTSSA/22961(B)/12+KA/2012/A1244 Date : 19/11/2012 Page: 1 o 13 CTS Re. CTSSA/12/3702/Tanaka TANAKA ELECTRONICS (M) SDN BHD PLOT 11, PHASE IV, BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG,

More information

Test Report No: (1) R1 Date: 29-Oct-10 Page 1 of 5

Test Report No: (1) R1 Date: 29-Oct-10 Page 1 of 5 Test Report No: 10213566(1) R1 Date: 29-Oct-10 Page 1 of 5 Dou Yee Enterprises (S) Pte Ltd 2304 Bedok Reservoir Road Bedok Industrial Park C (479223) THIS REPORT IS TO SUPERSEDE TEST REPORT NO.10213566(1)

More information

Test Report No. F690101/LF-CTSAYAA

Test Report No. F690101/LF-CTSAYAA Page 1 of SHINWONTECH 36BL 12LTNamdong-Industrial Area 610-11,Namchon-dong Namdong-gu,Incheon Korea The following sample(s) was/were submitted and identified by/on behalf of the client as:- SGS File No.

More information

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014 TECHNOVA IMAGING SYSTEMS (P) LTD. C-2 M.I.D.C. TALOJA, DIST. RAIGAD RAIGAD-410208 INDIA CONTACT PERSON : MR. VINAY KADAM THE FOLLOWING SAMPLE(S) WAS/WERE SUBMITTED AND IDENTIFIED BY/ON BEHALF OF THE CUSTOMER

More information

Test Report. Report No. RLSHD Page 1 of 6

Test Report. Report No. RLSHD Page 1 of 6 Report No. RLSHD000756910001 Page 1 of 6 Applicant Address WUJIANG MIGHTYTEK SEMICONDUCTOR CO.,LTD NO.2100 NORTH OF ZHONGSHAN ROAD,SONGLING TOWN,WUJIANG CITY Report on the submitted sample said to be Sample

More information

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE Report No. ECL01J068075001 Page 1 of 6 Applicant Address NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE The following sample(s) and sample information was/were

More information

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017 APPLICANT : CALIX ELECTRONIC CHEMICAL CO., LTD. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF

More information

Verification Report. No. CANEC Date: 12 Apr Page 1 of 9.

Verification Report. No. CANEC Date: 12 Apr Page 1 of 9. Verification Report. No. CANEC1302893701 Date: 12 Apr 2013. Page 1 of 9. PROMOVER INDUSTRIAL COMPANY LIMITED. N0.34 CHIA SHINE ROAD WAN LUAN VILLAGE PING TUNG COUNTRY 92343 TAIWAN. Sample Name :. SGS Job

More information

Test Report. Report No. ECL01H Page 1 of 7

Test Report. Report No. ECL01H Page 1 of 7 Report No. ECL01H067640001 Page 1 of 7 Applicant SHANGHAI SEEFULL ELECTRONIC CO., LTD LITE-ON SEMICONDUCTOR CORP. Address 6 ZHENYE RD. DONGJING INDUSTRIAL AREA SONGJIANG DISTRICT, SHANGHAI, CHINA 9F,NO.233-2

More information

Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CRS Ref. CRSSA/17/1742/CSC

Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CRS Ref. CRSSA/17/1742/CSC Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CSC STEEL SDN BHD 180, KAWASAN INDUSTRI AYER KEROH, AYER KEROH 75450 MELAKA, MALAYSIA The following merchandise was (were) submitted and identified

More information

Verification Result :.

Verification Result :. Verification Report. No. SZXEC1700532001 Date: 13 Jun 2017. Page 1 of 15. SHENZHEN REFLYING ELECTRONIC CO.,LTD. 6 BLDG, GAOXINJIAN INDUSTRIAL ZONE, HEPING VILLAGE,FUYONG TOWN,BAO AN DISTRICT,SHENZHEN,

More information

Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 CRS Ref. CRSSA/16/2799/Ametek

Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 CRS Ref. CRSSA/16/2799/Ametek Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 AMETEK ENGINEERED MATERIALS SDN BHD 48, HILIR SUNGAI KELUANG 2, PHASE 4 BAYAN LEPAS INDUSTRIAL ZONE, 11900 PENANG The following merchandise

More information

Test Report. Report No. RLSHE Page 2 of 7

Test Report. Report No. RLSHE Page 2 of 7 Report No. Page 1 of 7 Applicant LIGHT COUNTRY (CHANG SHU)CO.,LTD Address NO.88,NING BO ROAD,NEW HI-TECH INDUSTRY,CHANGSHU,JIANGSU,CHINA The following sample(s)and sample information was/were submitted

More information

Test Report. Report No. ECL01H Page 1 of 7

Test Report. Report No. ECL01H Page 1 of 7 Report No. ECL01H067806001 Page 1 of 7 Applicant LITE-ON MICROELECTRONICS (WUXI) CO., LTD. LITE-ON SEMICONDUCTOR CORP. Address LAND LOT J7 J8WEPZ, NEW DISTRICT, WUXI CITY, JIANGSU, CHINA 9F,NO.233-2 PAO-CHIAO

More information

Verification Result :.

Verification Result :. Verification Report. No. CANEC1405274901 Date: 05 May 2014. Page 1 17. AMERICAN POWER CONVERSION HOLDING INC.,TAIWAN BRANCH. 3F.,NO. 205, SEC.3, BEIXIN RD., 231 XINDIAN DIST., NEW TAIPEI CITY, 231 TAIWAN.

More information

Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong

Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong RoHS Screening Analysis Report Number : TWNC00152904 Applicant: Cactus Technologies Ltd Date : Apr 07, 2010 Suite C 15/F Capital Trade Center 62 Tsun Yip Street Kwun Tong Kowloon Hong Kong Sample Description:

More information

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5 Test Report No. SH9202593/CHEM Date: Oct. 22, 2009 Page 1 of 5 ROGERS CORPORATION 245 WOODSTOCK RD. WOODSTOCK, CT 06281 The following sample(s) was/were submitted and identified by/on behalf of the client

More information

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:- Applicant Address : PSMC Co., Ltd. : #52, Banyeo-1dong, Haeundae-gu, Busan, Korea Page : 1 of 9 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Name of Material

More information

Test Report. Report No. ECL01H Page 1 of 9

Test Report. Report No. ECL01H Page 1 of 9 Report No. ECL01H067809001 Page 1 of 9 Applicant Address LITE-ON MICROELECTRONICS (WUXI) CO., LTD. LITE-ON SEMICONDUCTOR CORP. LAND LOT J7 J8WEPZ, NEW DISTRICT, WUXI CITY, JIANGSU, CHINA 9F,NO.233-2 PAO-CHIAO

More information

Test Report No Date : 27/NOV/2017 Page 1 of 5

Test Report No Date : 27/NOV/2017 Page 1 of 5 Test Report No. 4346137-01 Date : 27/NOV/2017 Page 1 of 5 Ms. Anja Meyer The following samples were submitted and identified by/on behalf of the client as SGS Job file : 4346137 Order date : 06/NOV/2017

More information

TEST REPORT. The following sample(s) was(were) identified by the customer as : PP-NON WOVEN

TEST REPORT. The following sample(s) was(were) identified by the customer as : PP-NON WOVEN TEST REPORT To : ICON PACKAGING SDN. BHD. Report No. : IP1603-0608 No. 8, Jalan Pinang Emas 1, Taman Pinang Emas, Pinang Tunggal, Page No : 1 of 4 08000 Sungai Petani, Kedah. Date of Issue : 28/03/2016

More information

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5 Test Report No. 4346137-02_rev01 Date: 06/DEC/2017 Page 1 of 5 Ms. Anja Meyer The following samples were submitted and identified by/on behalf of the client as SGS Job file : 4346137 Order date : 06/NOV/2017

More information

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5

TEST REPORT Reference No. : TRHZ Date : Sep. 18, 2013 Page No. : 1 of 5 Reference No. : TRHZ1309618 Date : Sep. 18, 2013 Page No. : 1 of 5 Client : Address : TEFLEX GASKET CO., LTD. CIE INDUSTRIAL ZONE, CIXI CITY, ZHEJIANG, CHINA. The following merchandise was (were) submitted

More information

Test Report No. CRSSA/02575/18 Date : 09/03/2018 Page: 1 of 13 CRS Ref. CRSSA/18/0530/Dynacraft

Test Report No. CRSSA/02575/18 Date : 09/03/2018 Page: 1 of 13 CRS Ref. CRSSA/18/0530/Dynacraft Test Report No. CRSSA/02575/18 Date : 09/03/2018 Page: 1 of 13 DYNACRAFT INDUSTRIES SDN. BHD. 255-A, BLOCK D, PHASE II, BAYAN LEPAS INDUSTRIAL ZONE, 11900 PENANG, MALAYSIA. The following merchandise was

More information

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material APPLICANT : PSMC CO., LTD. ADDRESS : 16, Barangongdan-ro 4-gil, Hyangnam-eup, Hwaseong-si, Gyeonggi-do, Korea PAGE: 1 of 10 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE

More information

Test Report No. CRSSA/14109/17 Date : 24/11/2017 Page: 1 of 7 CRS Ref. CRSSA/17/2961/Ametek

Test Report No. CRSSA/14109/17 Date : 24/11/2017 Page: 1 of 7 CRS Ref. CRSSA/17/2961/Ametek Test Report No. CRSSA/14109/17 Date : 24/11/2017 Page: 1 of 7 AMETEK ENGINEERED MATERIALS SDN BHD 48, HILIR SUNGAI KELUANG 2, PHASE 4 BAYAN LEPAS INDUSTRIAL ZONE, 11900 PENANG The following merchandise

More information

Test Report No. F690101/LF-CTSAYGU

Test Report No. F690101/LF-CTSAYGU Page 1 of 11 POONGSAN CORPORATION 94 Sanam-ro,Onsan-eup Ulju-gun,Ulsan Korea The following sample(s) was/were submitted and identified by/on behalf of the client as:- SGS File No. Product Name : AYGU17-09143

More information

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory. Applicant : Doosan Corporation Electro-Materials Address : 40, Doosan-ro, Jeungpyeong-eup, Jeungpyeong-gun, Chungcheongbuk-do, Korea Page: 1 of 5 : The following submitted sample(s) said to be:- Name/Type

More information