Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN
|
|
- Gwen Linette Cummings
- 6 years ago
- Views:
Transcription
1 Problem P7 Stéphanie Ménard Dosimetry Department Fontenay-aux aux-roses FRANCE
2 What are the applications of Gamma-Ray Spectrometry in Radiological Protection and in Safety? In the environment: after accidental releases of radionuclides (contamination), for surveys over large areas In the control of nuclear materials In workplaces in the nuclear fuel cycle
3 What do we measure with a spectrometer? Pulse height distributions => Energy Peak count rates => Fluence
4 What physical information is essential? To determine radionuclide activity levels The activities are derived from measured full-energy peak count rates Knowledge of the detector peak response is essential but complex: Peak response depends on the photon energy and angle of incidence Assumptions are made to make measurements in the environment
5 What physical information is essential? To calculate dose quantities These quantities are derived from the energy distribution of incident radiation field To determine the energy spectrum: response matrix is needed Unfolding method is used
6 How to determine the influence of parameters on the response? Two methods Experimental method Numerical method Limits of the methods - experimental : irradiation conditions (energy, angle), cost - Numerical : assumptions on the geometry, detector noise
7 Example of a GeHP detector simulated by A.L. Weber (/DSMR/SATE) -Ray photograph of Ge 2D plot
8 Description of the geometry - Al cryostat Al holder γ Ge detector (core) Ge dead layer Be window
9 Proposed Tasks 1) Determination of peak efficiencies and PHD at 8 energies ( 15, 30, 60, 100, 250, 500, 750, 1000 kev) 2) Estimation of the influence of the following parameters: - dead layer thickness - Source distance - Angle 2 3) Estimation of the influence of the Al holder (optional) 4) Influence of the incidence angle on PHD (optional)
10 Participant Task 1 Task 2 Task 3 Task 4 Comment (optional) (optional) P7-A Doppler B. P7-B (peak) P7-C Doppler (peak) (peak) Broadening P7-D P7-E P7-F P7-G P7-H Doppler B. P7-I
11 Participant Task 1 Task 2 Task 3 Task 4 Comment (optional) (optional) P7-J P7-K (peak) (peak) P7-L (peak) P7-M P7-N P7-O P7-P Doppler B. P7-Q (peak) P7-R
12 Monte Carlo Codes used MCNP 4B, 4C, 4C2, 4C3 : P7-B, P7-D, P7-E, P7-F, P7-I, P7-L, P7-N, P7-O, P7-Q, P7-R MCNP 2.4.j : P7-G EGS4-UCDOD : P7-A EGS4 + KEK improvement: P7-H EGSNrc (v2): P7-M GEANT 3: P7-K PENELOPE v2001: P7-J Beta version of MCNP 5 : P7-P
13 Method used to analyze the results How to compare pulse height distributions? 100keV, Normal Pulse Height Dist rib. / source part icle Energy (MeV)
14 Method used to analyze the results Pulse height distribution divided into several areas Energy limits of the areas depend on the incident photon energy
15 Method used to analyze the results Counts per source particle in the energy binnings of these areas are summed The results of the sums are compared to the author s sums. The number of areas depend on the photon energy ( ex: 6 areas at 30 kev, 9 at 100 kev, 5 at 1 MeV) 6 areas for 30 kev: 1-4.2,4.2-9,9-14.8, , and kev
16 Task 1 Determination of peak efficiencies and pulse height distributions at 8 energies (15, 30, 60, 100, 250, 500, 750, 1000 kev). Peak efficiency is defined as the number of events in the full-energy peak per emitted particle
17 Task 1: Ratios of the 9 areas obtained for photons of 100 kev P7- A P7-C P7- D P7- E P7-F P7-G P7-H Ratio (participant/author) En (kev)
18 Task 1: Ratios of the 9 areas obtained for photons of 100 kev P7-A and P7-H: The effect of Doppler Broadening to response is simulated. The version of MCNP ( 4C2) used by the author does not take into account this effect. So the ratios obtained for the region kev are about 3. Results corresponding to Compton edge area are lower than the author s result. This effect is explained in the presentation of Dr Namito. The participant P7-C presents this effect in his report but his results are without Doppler Broadening
19 Doppler Broadening effect This effect changes the shape of pulse height distribution in these 3 Areas.
20 Task 1:100 kev P7-I P7-J P7-K P7-L P7-M P7-N P7-R Ratio (participant/author) En (kev)
21 Task 1: 100 kev 5 P7-B P7-D P7-E P7-H P7-Q Ratio (participant/author) En (kev)
22 Task 1: Ratios of the 9 areas obtained for photons of 100 kev P7-B: The source used is not isotropic and it is an annular ring source. P7-D: The participant simulated the 8 energies in 1 simulation using specific options of MCNP. But the results obtained were not multiplied by this factor 8. P7-E: MCNP code use default parameters for a surface source. The source emission is not isotropic P7-H: This participant forgot to normalize the results ( source emission in an hemi-sphere) P7-D, P7-E and P7-H computed simulations without these errors: their results are presented on the other figures
23 Task 1: Do the results depend on incident E? Ratio (participant/author) Energy: 750 kev P7-A P7-C P7-D P7-E P7-F P7-G P7-H En (kev) 5 areas: 2-168, , , , kev Results are close Effect of Doppler Broadening: smaller
24 Do the results depend on incident E? Energy : 30 kev At 30 kev, results are close only for the last area Ratio (participant/author) P7-A P7-C P7-D P7-E P7-F P7-H En (kev)
25 Task 1: Do the results depend on incident E? Ratio (participant/author) Energy: 750 kev P7-I P7-J P7-K P7-L P7-M P7-N P7-R En (kev) Ratio (participant/author) Energy : 30 kev P7-I P7-J P7-K P7-L P7-M P7-N En (kev)
26 Task 1: Results relative to incident E? Ratio (participant/author) Energy: 750 kev P7-B P7-D P7-E P7-H P7-M P7-P P7-Q Ratio (participant/author) Energy: 30 KeV P7-B P7-D P7-E P7-H P7-P P7-Q En (kev) En (kev)
27 Task 1: Results relative to incident E? Energy: 750 kev Energy: 30 KeV Ratio (participant/author) P7-B P7-D P7-E P7-H P7-M P7-0 P7-P P7-Q Ratio (participant/author) P7-B P7-D P7-E P7-H P7-O P7-P P7-Q En (kev) En (kev)
28 Task 1: peak efficiencies Ratio (participant/author) P7-A P7-C P7-D P7-E P7-F P7-G P7-H Ratio (participant/author) P7-I P7-J P7-K P7-L P7-N P7-R Photon energy (kev) Photon energy (kev)
29 Task 1: peak efficiencies thor) Ratio (participant/au P7-B P7-D P7-E P7-H P7-M P7-P P7-Q uthor) Ratio (participant/a P7-B P7-D P7-E P7-H P7-M P7-0 P7-P P7-Q Photon energy (kev) Photon energy (kev)
30 Task 1: Peak efficiencies P7-O: There is a problem with the description of the source (volume source and emission ) P7-P: this participant made an error on the distance between the detector and the source: 20 cm instead of 2 cm P7-Q: there is a little shift of energy on the PHD of the participant at 100 kev
31 What can we learn from this? Differences observed with the variation of incident E in the areas can be explained by physics model inside Monte Carlo codes = > Doppler Broadening feature ( presentation of Y. Namito) = > Author s results without this effect Factors of under-estimation or over-estimation are due to the source distribution ( annular ring, parallel beam, distance, volume source )
32 Task 2 Estimation of the influence of the following parameters: - dead layer thickness ( +/- 50%, 50 and 150 µm) - Source distance (+/- 50%, 1.95 and 2.05 cm) - Angle uncertainty (2 ) The influence of the dead layer thickness ( +/- 50%, 50 and 150 µm) depend on incident energy. At lower energies, this variation could give a factor 30. The presentation of Dr Achouri will focus on this point.
33 Task 2: Influence of the dead layer thickness on the peak efficiencies encies areas Ratio of the peak effici 10 1 Influence of DL: 50/100 Influence of DL : 150/ % Photon energy ( kev )
34 Task2: dead layer thickness uncertainty Dead layer uncertainty: - 50 % Dead layer : + 50 % Ratio (participant/author) P7-A P7-C P7-D P7-E P7-H P7-I P7-N P7-R Ratio (participant/author) P7-A P7-C P7-D P7-E P7-H P7-I P7-N P7-R Photon energy (kev) Photon energy (kev)
35 Task 2: Influence of the distance between the source and the Ge detector % on peak efficiencies Ratio of the peak efficiencies areas Influence of distance: 1.95 cm/ 2.00 cm Influence of distance: 2.05 cm / 2cm Photon energy ( kev )
36 Task 2: source distance uncertainty 1.3 Distance: 1.95 cm 1.1 Distance: 2.05 cm 1.25 Ratio (participant/author) P7-A P7-C P7-D P7-E P7-H P7-N P7-R Ratio (participant/author) P7-A P7-C P7-D P7-E P7-H P7-N P7-R Photon energy (kev) Photon energy (kev)
37 Task 2: angle uncertainty 1.1 Angle uncertainty: 2 thor) Ratio (participant/au P7-A P7-C P7-H P7-N Photon energy (kev)
38 Task 2 Results of the participants compared to the author s results have the same trends than the results of task 1.
39 Task 3 (optional) Influence of the Al Holder Any change on peak efficiencies P7- A P7-C P7-D P7-E P7-N
40 Influence of the Al Holder at 100 kev 1.1 Without Al Ratio (without Al Holder/with Al Holder) Factor En (kev)
41 Task 3 (optional) Important influence of the Al Holder observed only in the computations without Doppler broadening
42 What can we learn from this problem? Factors of under-estimation or over-estimation are mainly due to the source distribution ( annular ring, parallel beam, distance, volume source ) Users must be aware of that. At lower energies, physics model of the code could introduce important factors of under-estimation of numerical PHD compared to experimental ones.
43 Check-list for a Ge detector simulation Be careful of the dead layers thickness, Al holder, Source ( incident angle, distance ) Window Physics at lower energies
EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD
2011 International Nuclear Atlantic Conference - INAC 2011 Belo Horizonte,MG, Brazil, October 24-28, 2011 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-04-5 EFFICIENCY SIMULATION OF
More informationESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT
Proceedings of the Eleventh EGS4 Users' Meeting in Japan, KEK Proceedings 2003-15, p.107-113 ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT K. Noto and
More informationMonte Carlo modeling of an electronic brachytherapy source using MCNP5 and EGSnrc
Monte Carlo modeling of an electronic brachytherapy source using MCNP5 and EGSnrc Stephen D. Davis and Larry A. DeWerd University of Wisconsin, Madison, WI 13 th UK Monte Carlo User Group meeting March
More informationNeutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom
Neutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom Problem P4 Rick J Tanner National Radiological Protection Board Chilton, Didcot, Oxon OX11 0RQ, United Kingdom Intercomparison
More informationRecent Activities on Neutron Standardization at the Electrotechnical Laboratory
Recent Activities on Neutron Standardization at the Electrotechnical Laboratory K. Kudo, N. Takeda, S. Koshikawa and A. Uritani Quantum Radiation Division, National Metrology Institute of Japan (NMIJ)
More informationInternational Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN
308 Angular dependence of 662 kev multiple backscattered gamma photons in Aluminium Ravindraswami K a, Kiran K U b, Eshwarappa K M b and Somashekarappa H M c* a St Aloysius College (Autonomous), Mangalore
More informationPHYS 5020 Computation and Image Processing
PHYS 5020 and Image Processing : Monte Carlo Thursday 2 August 2012 Monte Carlo (MC) is a numerical method that uses random sampling of probability distributions to simulate stochastic processes in nature,
More informationSOME ASPECTS OF MONTE CARLO SIMULATION FOR EFFICIENCY CALIBRATION OF GERMANIUM DETECTORS
ICRM Gamma Spectrometry Workshop Paris, France 23-24 February 2009 SOME ASPECTS OF MONTE CARLO SIMULATION S.Hurtado Universidad de Sevilla SPAIN 1 MONTE CARLO SIMULATION DISADVANTAGES Self-absorption correction
More informationDetection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract
Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods N. Stefanakis 1 1 GMA Gamma measurements and analyses e.k. PO Box 1611, 72706 Reutlingen,
More informationThe first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.
Experimental and Monte Carlo determination of Gamma Spectrometry Efficiency Pavel Dryak, Petr Kovář Czech Metrology Institute February 2009 Leading motive of our testing The producer send the drawing after
More informationCurrent status of EGS5
Workshop on Computational Medical Physics (Nara, September. 2, 2012) Current status of EGS5 Comparison with experiment on e backscattering Y. Namito and H. Hirayama (KEK) History of EGS System Period Program
More informationCHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS
CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS Leonardo de Holanda Mencarini 1,2, Claudio A. Federico 1,2 and Linda V. E. Caldas 1 1 Instituto de Pesquisas Energéticas e Nucleares IPEN,
More informationMeasurement of induced radioactivity in air and water for medical accelerators
Measurement of induced radioactivity in air and water for medical accelerators K. Masumoto 1, K. Takahashi 1, H. Nakamura 1, A. Toyoda 1, K. Iijima 1, K. Kosako 2, K. Oishi 2, F. Nobuhara 1 High Energy
More informationMitigation of External Radiation Exposures
Mitigation of External Radiation Exposures The three (3) major principles to assist with maintaining doses ALARA are :- 1) Time Minimizing the time of exposure directly reduces radiation dose. 2) Distance
More informationCharacterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan
Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan Hideki Harano * National Metrology Institute of Japan, National
More informationDevelopment of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation
Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation S. Moriuchi, M.Tsutsumi2 and K. Saito2 Nuclear safety technology Center,
More informationRadiation Quantities and Units
Radiation Quantities and Units George Starkschall, Ph.D. Lecture Objectives Define and identify units for the following: Exposure Kerma Absorbed dose Dose equivalent Relative biological effectiveness Activity
More informationBonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.
Bonner Sphere Spectrometer Cruzate, J.A.; Carelli, J.L. and Gregori, B.N. Presentado en: Workshop on Uncertainty Assessment in Computational Dosimetry: a Comparison of Approaches. Bologna, Italia, 8-10
More informationResearchers at the University of Missouri-Columbia have designed a triple crystal
Childress, N. L. and W. H. Miller, MCNP Analysis and Optimization of a Triple Crystal Phoswich Detector, Nuclear Instruments and Methods, Section A, 490(1-2), 263-270 (Sept 1, 2002). Abstract Researchers
More informationCompton suppression spectrometry
Compton suppression spectrometry In gamma ray spectrometry performed with High-purity Germanium detectors (HpGe), the detection of low intensity gamma ray lines is complicated by the presence of Compton
More informationThe GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes
The GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes R. Marc Kippen Space and Remote Sensing Sciences Group, Los Alamos National Laboratory NIS-2, MS
More informationInternational Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN
316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science
More informationActivities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)
Activities of the neutron standardization at the Korea Research Institute of Standards and Science (KRISS) I. Introduction The activities of neutron standardization in KRISS have been continued for last
More informationPhD Qualifying Exam Nuclear Engineering Program. Part 1 Core Courses
PhD Qualifying Exam Nuclear Engineering Program Part 1 Core Courses 9:00 am 12:00 noon, November 19, 2016 (1) Nuclear Reactor Analysis During the startup of a one-region, homogeneous slab reactor of size
More informationUnfolding of neutron spectra with an experimentally determined diamond detector response function
Unfolding of neutron spectra with an experimentally determined diamond detector response function Physikalisch-Technische Bundesanstalt, D-38116 Braunschweig, Germany E-mails: Andreas.Zimbal@ptb.de, Marcel.Reginatto@ptb.de,
More informationElectron Impact Ionization in EGSnrc
Electron Impact Ionization in EGSnrc by Leila Lukhumaidze A thesis submitted to the Faculty of Graduate and Postdoctoral Affairs in partial fulfillment of the requirements for the degree of Master of Science
More informationCompton Camera. Compton Camera
Diagnostic Imaging II Student Project Compton Camera Ting-Tung Chang Introduction The Compton camera operates by exploiting the Compton Effect. It uses the kinematics of Compton scattering to contract
More informationRadiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 11 May 2007
Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp. 229 233 Advance Access publication 11 May 2007 doi:10.1093/rpd/ncm047 CHARACTERIZATION AND UTILIZATION OF A BONNER SPHERE SET BASED ON GOLD
More informationEffect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract
Organized and hosted by the Canadian Nuclear Society. Vancouver, BC, Canada. 2006 September 10-14 Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor
More information(a) Mono-absorber. (b) 4-segmented absorbers. (c) 64-segmented absorbers
Proceedings of the Ninth EGS4 Users' Meeting in Japan, KEK Proceedings 2001-22, p.37-42 EVALUATION OF ABSORPTION EFFICIENCY FOR NIS TUNNEL JUNCTION DETECTOR WITH SEGMENTED ABSORBERS R. Nouchi, I. Yamada,
More informationInteractive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools
10th Nuclear Science Training Course with NUCLEONICA, Cesme, Turkey, 8-10 October, 2008 1 Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools A.N. Berlizov ITU - Institute for Transuranium
More informationComparative Analysis of Nuclear Cross Sections in Monte Carlo Methods for Medical Physics Applications
Comparative Analysis of Nuclear Cross Sections in Monte Carlo Methods for Medical Physics Applications Christopher T. Myers 1 Georgia Institute of Technology Bernadette L. Kirk 2 Luiz C. Leal 2 Oak Ridge
More informationGamma ray coincidence and angular correlation
University of Cape Town Department of Physics Course III laboratory Gamma ray coincidence and angular correlation Introduction Medical imaging based on positron emission tomography (PET) continues to have
More informationAn extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter
An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter Christopher A Perks *a and Stephane Faugoin a a LANDAUER EUROPE, 33 Avenue du General Leclerc, F-92266, Fontenay-aux-Roses
More informationCharacterization and Monte Carlo simulations for a CLYC detector
Characterization and Monte Carlo simulations for a CLYC detector A. Borella 1, E. Boogers 1, R.Rossa 1, P. Schillebeeckx 1 aborella@sckcen.be 1 SCK CEN, Belgian Nuclear Research Centre JRC-Geel, Joint
More informationShielding of Ionising Radiation with the Dosimetry & Shielding Module
Shielding of Ionising Radiation with the Dosimetry & Shielding Module J. Magill Overview Biological Effects of Ionising Radiation - Absorber dose, Quality or Weighting Factor, Equivalent Dose Attenuation
More informationQuartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays
Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays Alison V. Goodsell, William S. Charlton alisong@tamu.edu, charlton@ne.tamu.edu Nuclear Security Science & Policy Institute Texas A&M University,
More informationRadiation Transport Tools for Space Applications: A Review
Radiation Transport Tools for Space Applications: A Review Insoo Jun, Shawn Kang, Robin Evans, Michael Cherng, and Randall Swimm Mission Environments Group, February 16, 2008 5 th Geant4 Space Users Workshop
More informationLaboratoire National Henri Becquerel (CEA/LIST/LNHB), France (2) ENEA-Radiation Protection Institute, Bologna, Italy (3)
PROPOSAL FOR EYE-LENS DOSEMETER CALIBRATION AND TYPE TESTING ORAMED WP2 J.-M. Bordy (1), J. Daures (1), M. Denozière (1), G. Gualdrini (2), M. Guijaume (3), E. Carinou (4),F. Vanhavere (5) (1) Laboratoire
More informationResponse Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations
Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations 271 I. ORION 1,2 1 AND L. WIELOPOLSKI 2, 1 St. Luke=s/Roosevelt Hospital, Columbia University, New York, NY 10025,USA 2
More informationEvaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods
Asian J. Exp. Sci., Vol. 28, No. 2, 2014; 23-31 Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods Rahim Khabaz, Farhad Yaghobi
More informationDosimetry of External Photon Fields Using Unfolding of Scintillation Gamma Spectrometry Data
Dosimetry of External Photon Fields Using Unfolding of Scintillation J. Kluson, Tomas Cechak, Prague ntroduction The mathematical processing (unfolding) of pulse height spectra from a scintillation detector
More informationDigital simulation of neutron and gamma measurement devices
3Security of radioactive materials and transport 3 2 Digital simulation of neutron and gamma measurement devices A.-L. WEBER (IRSN) 1 - Maximum activity that a radioactive element can present without being
More informationApplied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra
22.101 Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra References: W. E. Meyerhof, Elements of Nuclear Physics (McGraw-Hill, New York, 1967),
More informationSurvey Meter OD-01 Address: Phone: Fax: URL:
Survey Meter OD-01 Dose meter and dose rate meter for the measurement of the ambient dose and dose rate equivalent H*(10), dh*(10)/dt and the directional dose and dose rate equivalent H'(0.07), dh'(0.07)/dt
More informationTITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137
TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137 AUTHORS: J. Cardoso, L. Santos, C. Oliveira ADRESS: Instituto Tecnológico e Nuclear Estrada Nacional 10; 2686-953 Sacavém;
More informationMEASUREMENT AND DETECTION OF RADIATION
MEASUREMENT AND DETECTION OF RADIATION Second Edition Nicholas Tsoulfanidis University of Missouri-Rolla Ж Taylor &Francis * Publishers since I79H CONTENTS Preface to the First Edition Preface to the Second
More informationGLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY
GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY ABSORBED DOSE: The amount of energy absorbed, as a result of radiation passing through a material, per unit mass of material. Measured in rads (1 rad
More informationZ 14. 2, 3, 4, 7, 10, 13 Contaminated Soil (Photon source) 5, 6, 9, 11, 12 Gap 8 NaI Crystal
Proceedings of the Ninth EGS4 Users' Meeting in Japan, KEK Proceedings 21-22, p.43-47 EGS4 CALCULATION OF A NaI SCINTILLATION SURVEY METER FOR THE EVALUATION OF 137 Cs CONTAMINATION IN SOIL A. Toyoda,
More informationCHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE
CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE Page no. 5.1 Introduction 132 5.2 Methods and measurements 132 5.3 Saturation thickness of elements and polymers
More informationGamma-Spectrum Generator
1st Advanced Training Course ITCM with NUCLEONICA, Karlsruhe, Germany, 22-24 April, 2009 1 Gamma-Spectrum Generator A.N. Berlizov ITU - Institute for Transuranium Elements Karlsruhe - Germany http://itu.jrc.ec.europa.eu/
More informationTRAINING IN EXTERNAL DOSIMETRY CALCULATIONS WITH COMPUTATIONAL CODES
TRAINING IN EXTERNAL DOSIMETRY CALCULATIONS WITH COMPUTATIONAL CODES S. MORATÓ, A.BERNAL, A. QUEROL, A. ABARCA, C. GÓMEZ-ZARZUELA, R.MIRÓ, G.VERDÚ Institute for Industrial, Radiophysical and Environmental
More informationStructure of Biological Materials
ELEC ENG 3BA3: Structure of Biological Materials Notes for Lecture #19 Monday, November 22, 2010 6.5 Nuclear medicine imaging Nuclear imaging produces images of the distribution of radiopharmaceuticals
More informationQuality Assurance. Purity control. Polycrystalline Ingots
Quality Assurance Purity control Polycrystalline Ingots 1 Gamma Spectrometry Nuclide Identification Detection of Impurity Traces 1.1 Nuclides Notation: Atomic Mass Atomic Number Element Neutron Atomic
More informationMinimum Detectable and Maximum Missable Activities
and Maximum Missable The HPA Approach David Williams 18 May 2005 Centre for Radiation, Chemical and Environmental Hazards Radiation Protection Division formerly the National Radiological Protection Board
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA
The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool 13461 Victor Potapov, Alexey Safronov, Oleg Ivanov, Sergey Smirnov, Vyacheslav Stepanov National Research
More informationCalibration of the GNU and HSREM neutron survey instruments
Calibration of the GNU and HSREM neutron survey instruments Neutron Users Club Meeting National Physical Laboratory 20 th October 2015 J. S. Eakins 1, L. G. Hager 1, J. W. Leake 2, R. S. Mason 2 and R.
More informationAnalysis of radioinduced DNA damages using Monte Carlo calculations at nanometric scale for different irradiation configurations
DOI: 10.15669/pnst.4.413 Progress in Nuclear Science and Technology Volume 4 (2014) pp. 413-417 ARTICLE Analysis of radioinduced DNA damages using Monte Carlo calculations at nanometric scale for different
More informationEfficiency and Attenuation in CdTe Detectors
Efficiency and Attenuation in CdTe Detectors Amptek Inc. Bob Redus, May 5, 00 Amptek s XR-00T-CdTe is a high performance x-ray and gamma ray detector system. Like Amptek s other XR00 products, a detector
More informationBasic hands-on gamma calibration for low activity environmental levels
Basic hands-on gamma calibration for low activity environmental levels Iolanda Osvath Presented by Mats Eriksson Environment Laboratories Marine Environment Laboratories, Monaco Radiometrics Laboratory
More informationApplication of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence
2009 IEEE Nuclear Science Symposium Conference Record N04-4 Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence W.J. Walsh, S.D. Clarke, S.A. Pozzi, IEEE
More informationCalculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*
SLAC-PUB-70 Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials* J. C. Liu, K. R. Kase, X. S. Mao, W. R. Nelson, J. H. Kleck, and S. Johnson ) Stanford Linear
More informationGeorgia Institute of Technology. Radiation Detection & Protection (Day 3)
Georgia Institute of Technology The George W. Woodruff School of Mechanical Engineering Nuclear & Radiological Engineering/Medical Physics Program Ph.D. Qualifier Exam Spring Semester 2009 Your ID Code
More informationSLAC Metal Clearance Program and Progress
1 SLAC Metal Clearance Program and Progress James Liu, Jim Allan, Ryan Ford, Ludovic Nicolas, Sayed Rokni and Henry Tran Radiation Protection Department SLAC National Accelerator Laboratory, USA RadSynch,
More information(1) : Laboratoire de Physique Corpusculaire, Campus des Cézeaux, Clermont-Ferrand
Intercomparison on the Usage of Computational Codes in Radiation Dosimetry P1 : Brachytherapy : 192 Ir γ-ray source. Calculation of angular anisotropy and dose distribution in water Lucie Berger (1), Lydia
More informationPHYS 3650L - Modern Physics Laboratory
PHYS 3650L - Modern Physics Laboratory Laboratory Advanced Sheet Photon Attenuation 1. Objectives. The objectives of this laboratory exercise are: a. To measure the mass attenuation coefficient at a gamma
More informationA Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy
LLNL-TR-518852 A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy S. Friedrich December 6, 2011 Disclaimer This document was prepared as an account of work sponsored by
More informationEffect of the time characteristics of the Compton camera on its performance
Effect of the time characteristics of the Compton camera on its performance Chibueze Zimuzo Uche Howell Round Michael Cree School of Engineering University of Waikato Introduction Anger camera Compton
More informationMeasurements with the new PHE Neutron Survey Instrument
Measurements with the new PHE Neutron Survey Instrument Neutron Users Club Meeting National Physical Laboratory 16 th October 2013 Jon Eakins, Rick Tanner and Luke Hager Centre for Radiation, Chemicals
More informationCALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo
CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo Oak Ridge National Laboratory Oak Ridge, TN 37831-6010 PO Box 2008 Ms6010 ABSTRACT The
More informationSpecific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements
Specific Accreditation Criteria Calibration ISO/IEC 17025 Annex Ionising radiation measurements January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected
More informationSimulating Gamma-Ray Telescopes in Space Radiation Environments with Geant4: Detector Activation
Simulating Gamma-Ray Telescopes in Space Radiation Environments with Geant4: Detector Activation Andreas Zoglauer University of California at Berkeley, Space Sciences Laboratory, Berkeley, USA Georg Weidenspointner
More informationAn introduction to Neutron Resonance Densitometry (Short Summary)
An introduction to Neutron Resonance Densitometry (Short Summary) H. Harada 1, M. Koizumi 1, H. Tsuchiya 1, F. Kitatani 1, M. Seya 1 B. Becker 2, J. Heyse 2, S. Kopecky 2, C. Paradela 2, P. Schillebeeckx
More informationDevelopment of Gamma-ray Monitor using CdZnTe Semiconductor Detector
Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector A. H. D. Rasolonjatovo 1, T. Shiomi 1, T. Nakamura 1 Y. Tsudaka 2, H. Fujiwara 2, H. Araki 2, K. Matsuo 2, H. Nishizawa 2 1 Cyclotron
More informationGy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.
Absorbed Dose Dose is a measure of the amount of energy from an ionizing radiation deposited in a mass of some material. SI unit used to measure absorbed dose is the gray (Gy). 1J 1 Gy kg Gy can be used
More informationValidation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF)
Validation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF) T. Brall1, M. Dommert2, W. Rühm1, S. Trinkl3, M. Wielunski1, V. Mares1 1 Helmholtz
More informationRecent Activities on Neutron Calibration Fields at FRS of JAERI
Recent Activities on Neutron Calibration Fields at FRS of JAERI Michio Yoshizawa, Yoshihiko Tanimura, Jun Saegusa and Makoto Yoshida Department of Health Physics, Japan Atomic Energy Research Institute
More informationA CdTe detector with a Gd converter for thermal neutron detection
A CdTe detector with a Gd converter for thermal neutron detection Aki Miyake, Takahiro Nishika, Shailendra Singh, Hisashi Morii, Hidenori Minura, Toru Aoki. Nuclear Instruments and Methods in Physics Research
More informationBecome Aware: Preparation for a Radiological Terrorism Event Ionizing Radiation and Its Biological and Human Health Effects
Become Aware: Preparation for a Radiological Terrorism Event Ionizing Radiation and Its Biological and Human Health Effects The University of Texas Health Science Center at San Antonio November 12, 2002
More informationUpcoming features in Serpent photon transport mode
Upcoming features in Serpent photon transport mode Toni Kaltiaisenaho VTT Technical Research Centre of Finland Serpent User Group Meeting 2018 1/20 Outline Current photoatomic physics in Serpent Photonuclear
More informationUpdate on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)
Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS) K. Garrow 1, B.J. Lewis 2, L.G.I. Bennett 2, M.B. Smith, 1 H. Ing, 1 R. Nolte, 3 S. Röttger, R 3 R. Smit 4
More informationDesign and Use of an Interim Noble Gas Effluent Monitor at Columbia Generating Station
Design and Use of an Interim Noble Gas Effluent Monitor at Columbia Generating Station RETS-REMP & EPRI Groundwater Protection Workshop June 25-27th, 2013 Westminster, CO Eric L. Darois, CHP (RSCS) Jim
More informationRESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS
RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS S. Prasad *, A. Enqvist, S. D. Clarke, S. A. Pozzi, E. W. Larsen 1 Department of Nuclear Engineering and Radiological
More informationDead Layer and Active Volume Determination for GERDA Phase II
Dead Layer and Active Volume Determination for GERDA Phase II Björn Lehnert on behalf of the GERDA Collaboration DPG Spring Meeting 05/02/2013 Dresden Institut für Kern- und Teilchenphysik Dead Layer (DL)
More informationVladimir Sobes 2, Luiz Leal 3, Andrej Trkov 4 and Matt Falk 5
A Study of the Required Fidelity for the Representation of Angular Distributions of Elastic Scattering in the Resolved Resonance Region for Nuclear Criticality Safety Applications 1 Vladimir Sobes 2, Luiz
More informationProject Memorandum. N N o. = e (ρx)(µ/ρ) (1)
Project Memorandum To : Jebediah Q. Dingus, Gamma Products Inc. From : Patrick R. LeClair, Material Characterization Associates, Inc. Re : 662 kev Gamma ray shielding Date : January 5, 2010 PH255 S10 LeClair
More information2015 Ph.D. Comprehensive Examination III. Radiological Sciences - Medical Physics
January 2015 2015 Ph.D. Comprehensive Examination III Radiological Sciences - Medical Physics In this three-hour exam, you are required to answer all of the questions in Part A and any two (2) out of the
More informationRecent developments in neutron metrology at the Institute for Radiological Protection and Nuclear Safety (IRSN)
Recent developments in neutron metrology at the Institute for Radiological Protection and Nuclear Safety (IRSN) V.Gressier, L. Van Ryckeghem, B. Asselineau, R. Babut, J.F. Guerre-Chaley, V. Lacoste, L.Lebreton,
More informationSIMPLE USE OF EGS4 BY EXCEL MACRO FILE
Proceedings of the Tenth EGS4 Users' Meeting in Japan, KEK Proceedings 2002-18, p.10-14 SIMPLE USE OF EGS4 BY EXCEL MACRO FILE T. Uchibori Radiation Engineering Dept, Aloka Corporation 22-1, Mure-6, Mitaka-shi,
More informationEnergy response for high-energy neutrons of multi-functional electronic personal dosemeter
Energy response for high-energy neutrons of multi-functional electronic personal dosemeter T. Nunomiya 1, T. Ishikura 1, O. Ueda 1, N. Tsujimura 2,, M. Sasaki 2,, T. Nakamura 1,2 1 Fuji Electric Systems
More informationAn Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles
An Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles 1) A Kumar 1 and A.J. Waker 1 Faculty of Energy System and Nuclear Science, UOIT, 2000 Simcoe St. N,
More informationNeutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden
Neutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden A. Klix1, A. Domula2, U. Fischer1, D. Gehre2, J. Henniger2,
More informationABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER
ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER M. Bovi (1), R.F. Laitano (1), M. Pimpinella (1), M. P. Toni (1), K. Casarin(2), E. Quai(2), G. Tromba(2), A. Vascotto(2),
More informationA new neutron monitor for pulsed fields at high-energy accelerators
A new neutron monitor for pulsed fields at high-energy accelerators Marlies Luszik-Bhadra *, Eike Hohmann Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116, Braunschweig, Germany. Abstract.
More informationChapter V: Cavity theories
Chapter V: Cavity theories 1 Introduction Goal of radiation dosimetry: measure of the dose absorbed inside a medium (often assimilated to water in calculations) A detector (dosimeter) never measures directly
More informationTransport under magnetic fields with the EGSnrc simulation toolkit
Transport under magnetic fields with the EGSnrc simulation toolkit Ernesto Mainegra-Hing, Frédéric Tessier, Blake Walters Measurement Science and Standards, National Research Council Canada Hugo Bouchard
More informationMCNP analysis and optimization of a double crystal phoswich detector
EURONS I3 506065 JRA9 RHIB Report made during stay IEM-CSIC Madrid January 2008 MINISTERIO DE ASUNTOS EXTERIORES Y DE COOPERACIÓN AECI VICESECRETARÍA GENERAL MCNP analysis and optimization of a double
More informationCalibration of A Small Anode Germanium Well Detector
Calibration of A Small Anode Germanium Well Detector DTU Nutech, Roskilde, Denmark Joonas Tikkanen Introduction Small anode germanium (SAGe) well detector manufactured by Canberra/Mirion Measurements possible
More informationNGN PhD Studentship Proposal
NGN PhD Studentship Proposal Note that proposals will be assessed against both the quality of the scientific content and of the proposed training experience. Proposed supervisors (lead first) Dr Laura
More informationGeneral Physics (PHY 2140)
General Physics (PHY 2140) Lecture 19 Modern Physics Nuclear Physics Nuclear Reactions Medical Applications Radiation Detectors Chapter 29 http://www.physics.wayne.edu/~alan/2140website/main.htm 1 Lightning
More information