Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde
|
|
- Branden Norris
- 6 years ago
- Views:
Transcription
1 For the benefit of VaporFi, Inc. Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde GC/MS/MS Analysis 1-Aminonaphthalene, 2-Aminonaphthalene, 4-Aminobiphenyl Enthalpy Analytical, Inc. Phone: (919) / Fax: (919) / Capitola Drive Durham, NC
2 I certify that to the best of my knowledge all analytical data presented in this report: Have been checked for completeness Are accurate, error-free, and legible Have been conducted in accordance with approved protocol, and that all deviations and analytical problems are summarized in the appropriate narrative(s) This analytical report was prepared in Portable Document Format (.PDF) and contains 97 pages. Report Issued: 09/16/2014 EA# B Page 2 of 97
3 Summary of Results EA# B Page 3 of 97
4 Report for: For the benefit of VaporFi, Inc. Project Code: Client Project: RM02 & HPHC Testing Project Start Date: 08/07/2014 Sample Type: eliquid Analysis Method: ENT301 Enthalpy Code Client Code Dilution Factor Acetaldehyde (ug/ml) Acrolein (ug/ml) Crotonaldehyd e (ug/ml) Formaldehyde (ug/ml) RM < 1.07 ND < 1.09 ND 10.2 ND: Not Detected; analytes not detected above the MDL Compound / Dilution MS Catch Spike Amnt Native Amnt Recovery Sample ID Factor (ug) (ug) (ug) % Acetaldehyde MS % Acrolein MS % Crotonaldehyde MS % Formaldehyde MS % carbo.xlsx, carb Page 1 of 1 EA# B Page 4 of 97 09/16/ :03
5 Report for: For the benefit of VaporFi, Inc. Project Code: Client Project: RM02 & HPHC Testing Project Start Date: 08/07/2014 Sample Type: eliquid Analysis Method: GC/MS/MS Enthalpy Code Client Code 1-ANP (ng/ml) 2-ANP (ng/ml) 4-ABP (ng/ml) an4 (ug/ml) RM < 1.81 ND < 1.80 ND < ND < 1.10 ND ND: Not Detected; analytes not detected above the minimum detection limit. Compound / MS Sample Spiked Native Recovery Sample ID (ng) (ng) (ng) % 1-ANP MS % 2-ANP MS % 4-ABP MS % ND: Not Detected; analytes not detected above the minimum detection limit. Analyte Code 1-ANP: 1-Aminonaphthalene 2-ANP: 2-Aminonaphthalene 4-ABP: 4-Aminobiphenyl B eliq ArAm.xlsx, AA Page 1 of 1 EA# B Page 5 of 97 09/16/ :39
6 Narrative Summary EA# B Page 6 of 97
7 Enthalpy Analytical Narrative Summary Company For the benefit of VaporFi, Inc. Eliquid samples Analyst WJG / ETA Job # Parameters HPLC/UV Analysis # Samples 1 Custody Analysis Summer Mims received the samples on 8/7/14 after being relinquished by for the benefit of VaporFi, Inc. The samples were received at ambient temperature in good condition. Prior to, during, and after analysis, the samples were kept under lock with access only to authorized personnel by Enthalpy Analytical, Inc. The samples were analyzed for acetaldehyde, acrolein, crotonaldehyde, and formaldehyde following the analytical procedures in Enthalpy SOP ENT301. The Agilent Model 1100, High Performance Liquid Chromatograph "Groucho" was equipped with an Ultraviolet (UV) Detector operating at 365 nm and an appropriate column. Calibration QC Notes The calibration curve is located in the Carbonyls Raw Data section of this report. Acetaldehyde, acrolein, formaldehyde, and crotonaldehyde were not detected in the blank at levels above the minimum detection limit (MDL). A matrix spike (MS) was prepared using an aliquot of the sample. The recovery values were within 30% of the expected values. Reporting Notes The reported concentrations (ug/ml) were calculated by multiplying the diluted results by the dilution factor. The data in the Raw Data section of the report are diluted and have not been adjusted for the dilution factor. The results presented in this report are representative of the sample as provided to the laboratory. EA# B Page 7 of 97
8 Enthalpy Analytical Narrative Summary Company For the benefit of VaporFi, Inc. Eliquid samples Analyst SSB Job # Parameters GC/MS/MS Analysis # Samples 1 Custody Summer Mims received the samples on 8/7/14 after being relinquished by for the benefit of VaporFi, Inc. The samples were received at ambient temperature in good condition. Prior to, during, and after analysis, the samples were kept under lock with access only to authorized personnel by Enthalpy Analytical, Inc. Analysis The liquid samples were analyzed for 1-aminonaphthalene (1-ANP), 2- aminonaphthalene (2-ANP), and 4-aminobiphenyl (1-ABP) following the general analytical procedures for GC/MS analyses and Enthalpy SOP ENT213. Aliquots of 0.5 ml of each sample were combined with 4.5mL of HCl and 0.1mL of internal standard. The Agilent Model 7890A Gas Chromatograph Bender was coupled to an Agilent Model 5975 Mass Selective Detector and was fitted with an appropriate column. Calibration QC Notes Refer to the Aromatic Amines Raw Data section of this report for chromatograms. The target analytes were not detected in the laboratory blank or the sample above the MDL. A matrix spike (MS) was prepared using an aliquot of the sample. The recovery values were within 15% of the expected values Reporting Notes The reported < concentrations were calculated by dividing the MDL ng by the sample aliquot volume (0.5 ml) used for the analysis. The chromatograms in the Raw Data section of the report present the results in units of ng. The results presented in this report are representative of the samples as provided to the laboratory. EA# B Page 8 of 97
9 General Reporting Notes The following are general reporting notes that are applicable to all Enthalpy Analytical, Inc. data reports, unless specifically noted otherwise. Any analysis which refers to the method as Type represents a planned deviation from the reference method. For instance a Hydrogen Sulfide assay from a Tedlar bag would be labeled as EPA Method 16-Type because Tedlar bags are not mentioned as one of the collection options in EPA Method 16. The acronym MDL represents the Minimum Detection Limit. Below this value the laboratory cannot determine the presence of the analyte of interest reliably. The acronym LOQ represents the Limit of Quantification. Below this value the laboratory cannot quantitate the analyte of interest within the criteria of the method. The acronym ND following a value indicates a non-detect or analytical result below the MDL. The letter J in the Qualifier or Flag column in the results indicates that the value is between the MDL and the LOQ. The laboratory can positively identify the analyte of interest as present, but the value should be considered an estimate. The letter E in the Qualifier or Flag column indicates an analytical result exceeding 100% of the highest calibration point. The associated value should be considered as an estimate. The acronym DF represents Dilution Factor. This number represents dilution of the sample during the preparation and/or analysis process. The analytical result taken from a laboratory instrument is multiplied by the DF to determine the final undiluted sample results. The addition of MS to the Sample ID represents a Matrix Spike. An aliquot of an actual sample is spiked with a known amount of analyte so that a percent recovery value can be determined. The MS analysis indicates what effect the sample matrix may have on the target analyte, i.e. whether or not anything in the sample matrix interferes with the analysis of the analyte(s). The addition of MSD to the Sample ID represents a Matrix Spike Duplicate. Prepared in the same manner as a MS, the use of duplicate matrix spikes allows further confirmation of laboratory quality by showing the consistency of results gained by performing the same steps multiple times. The addition of LD to the Sample ID represents a Laboratory Duplicate. The analyst prepares an additional aliquot of sample for testing and the results of the duplicate analysis are compared to the initial result. The result should have a difference value of within 10% of the initial result (if the results of the original analysis are greater than the LOQ). The addition of AD to the Sample ID represents an Alternate Dilution. The analyst prepares an additional aliquot at a different dilution factor (usually double the initial factor). This analysis helps confirm that no additional compound is present and coeluting or sharing absorbance with the analyte of interest, as they would have a different response/absorbance than the analyte of interest. EA# B Page 9 of 97
10 General Reporting Notes (continued) The Sample ID LCS represents a Laboratory Control Sample. Clean matrix, similar to the client sample matrix, prepared and analyzed by the laboratory using the same reagents, spiking standards and procedures used for the client samples. The LCS is used to assess the control of the laboratory s analytical system. Whenever spikes are prepared for our client projects, two spikes are retained as LCSs. The LCSs are labeled with the associated project number and kept in-house at the appropriate temperature conditions. When the project samples are received for analysis, the LCSs are analyzed to confirm that the analyte could be recovered from the media, separate from the samples which were used on the project and which may have been affected by source matrix, sample collection and/or sample transport. Significant Figures: Where the reported value is much greater than unity (1.00) in the units expressed, the number is rounded to a whole number of units, rather than to 3 significant figures. For example, a value of 10, ug catch is rounded to 10,456 ug. There are five significant digits displayed, but no confidence should be placed on more than two significant digits. Manual Integration: The data systems used for processing will flag manually integrated peaks with an M. There are several reasons a peak may be manually integrated. These reasons will be identified by the following two letter designations on sample chromatograms, if provided in the report. The peak was not integrated by the software NI, the peak was integrated incorrectly by the software II or the wrong peak was integrated by the software WP. These codes will accompany the analyst s manual integration stamp placed next to the compound name on the chromatogram. EA# B Page 10 of 97
11 Sample Custody Record EA# B Page 11 of 97
12 For the benefit of VaporFi, Inc. EA# B Page 12 of 97
13 EA# B Page 13 of 97 Raw Data
14 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D /4/2014 1:19:20 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :37:58 PM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Sample Location: 51 Injection volume: Injection: 1 of 1 File_Version 8 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde VB ug/ml Acrolein ug/ml Crotonaldehyde ug/ml 4 cmpds GoodCat [Rev. 2] Printed: 09/11/ :09:06 Page 1 of 1 EA# B Page 14 of 97
15 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D DNPH Blank 9/4/2014 2:21:39 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Sample Location: 53 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde ug/ml Acetaldehyde ug/ml Acrolein ug/ml Crotonaldehyde ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 2 of 6 EA# B Page 15 of 97
16 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #4 9/4/2014 6:30:31 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :11:13 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein BB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 3 of 6 EA# B Page 16 of 97
17 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO127\ D Sample name: HPLC-STDs014 #4 File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/5/ :52:29 AM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/2014 3:20:18 PM Instrument: Sequence_Name GROUCHO127 Acq. operator: Wendy Gardow Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein VB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 4 of 6 EA# B Page 17 of 97
18 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO127\ D MS 9/5/ :25:58 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/2014 3:20:18 PM Groucho GROUCHO127 Wendy Gardow Enthalpy Analytical, Inc. Sample type: Sample Location: 72 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde VV ug/ml Acetaldehyde BB ug/ml Acrolein VV ug/ml Crotonaldehyde VB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 5 of 6 EA# B Page 18 of 97
19 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO127\ D HPLC-STDs014 #4 9/5/ :57:09 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/2014 3:20:18 PM Groucho GROUCHO127 Wendy Gardow Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein VB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 6 of 6 EA# B Page 19 of 97
20 Sequence Summary Report Sequence_AcquiredBy Sequence_AcquiredDate Sequence_Name Sequence_LastModifiedBy Erik Alvarez 9/3/2014 3:56:35 PM GROUCHO126 Wendy Gardow Sequence_Ver 6 Name Acetaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Acetoin Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Name Acetone Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 20 of 97
21 Sequence Summary Report Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Acrolein Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Crotonaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Diacetyl Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 21 of 97
22 Sequence Summary Report Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Name Formaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Pentanedione Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 22 of 97
23 Sequence Summary Report Sequence_AcquiredBy Sequence_AcquiredDate Sequence_Name Sequence_LastModifiedBy Erik Alvarez 9/3/2014 3:56:35 PM GROUCHO126 Wendy Gardow Sequence_Ver 6 Name Acetaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acetoin Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acetone Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acrolein Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Crotonaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Diacetyl Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Formaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Pentanedione Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 23 of 97
24 Sequence Summary Report Sample_ID HPLC-STDs014 #SS HPLC-STDs014 #RB Sample_Type Control Control Vial 8 9 RT Area Dil 1 1 Amount Unit ug/ml ug/ml HPLC-STDs015 #SS HPLC-STDs015 #RB Control Control ug/ml ug/ml Compound Acetaldehyde : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Acetoin : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 24 of 97
25 Sequence Summary Report Compound Acetone : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Acrolein : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 25 of 97
26 Sequence Summary Report Compound Crotonaldehyde : Signal: VWD1A Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: Compound Diacetyl : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 26 of 97
27 Sequence Summary Report Compound Formaldehyde : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Pentanedione : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 27 of 97
28 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #1 9/3/2014 3:58:25 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :13:15 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 1 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde MM ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 1 of 18 EA# B Page 28 of 97
29 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #2 9/3/2014 4:29:31 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 2 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde MM ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 2 of 18 EA# B Page 29 of 97
30 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #3 9/3/2014 5:00:43 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 3 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 3 of 18 EA# B Page 30 of 97
31 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #4 9/3/2014 5:31:49 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 4 of 18 EA# B Page 31 of 97
32 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #5 9/3/2014 6:03:16 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 5 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 5 of 18 EA# B Page 32 of 97
33 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #6 9/3/2014 6:34:26 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 6 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 6 of 18 EA# B Page 33 of 97
34 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #7 9/3/2014 7:05:33 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 7 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 7 of 18 EA# B Page 34 of 97
35 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #SS 9/3/2014 7:36:42 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 8 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 8 of 18 EA# B Page 35 of 97
36 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #RB 9/3/2014 8:07:53 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 9 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 9 of 18 EA# B Page 36 of 97
37 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #1 9/3/2014 8:39:04 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 91 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BB ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 10 of 18 EA# B Page 37 of 97
38 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #2 9/3/2014 9:10:12 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 92 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BB ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 11 of 18 EA# B Page 38 of 97
39 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #3 9/3/2014 9:41:22 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 93 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 12 of 18 EA# B Page 39 of 97
40 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #4 9/3/ :12:30 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 94 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 13 of 18 EA# B Page 40 of 97
41 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO126\ D Sample name: HPLC-STDs015 #5 File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/3/ :43:40 PM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/ :10:52 AM Instrument: Sequence_Name GROUCHO126 Acq. operator: Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 95 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 14 of 18 EA# B Page 41 of 97
42 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #6 9/3/ :14:45 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 96 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione VV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 15 of 18 EA# B Page 42 of 97
43 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #7 9/3/ :45:55 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 97 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione VV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 16 of 18 EA# B Page 43 of 97
44 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #SS 9/4/ :17:06 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 98 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde VB ug/ml Diacetyl BB ug/ml Acetone BB ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 17 of 18 EA# B Page 44 of 97
45 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO126\ D Sample name: HPLC-STDs015 #RB File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/4/ :48:09 AM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/ :10:52 AM Instrument: Sequence_Name GROUCHO126 Acq. operator: Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 99 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 18 of 18 EA# B Page 45 of 97
46 EA# B Page 46 of 97 Raw Data
47 Quantitative Analysis Summary Report Batch Data Path D:\Data\MS2014Q3\Bender\data\sep14\Bender p0046\quantresults\bender p ArAm eliq.batch.bin Analysis Time 9/16/ :28 AM Analyst Name EAINC\SBrown Report Time 9/16/ :29 AM Reporter Name EAINC\SBrown Last Calib Update 9/16/ :28 AM Batch State Processed T11:28: : T11:29: : T11:28: :00 Quantitation Results Target Compound 1-ANP SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 1-ANP LAH ArAm ISTD blk Blank B D T11:4 1-ANP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 1-ANP LAH ArAm Std 3 Calibration 3 B D T12:1 1-ANP LAH ArAm Std 4 Calibration 4 B D T12:2 1-ANP LAH ArAm Std 5 Calibration 5 B D T12:3 1-ANP LAH ArAm ISTD blk Blank B D T12:4 1-ANP 1 0 LAH ArAm SS Std QC SS B D T12:5 1-ANP LAH Concal (ArAm Std 4) QC 4 B D T13:1 1-ANP LAH Concal (ArAm Std 4) QC 4 B D T10:1 1-ANP LAH Sample B D T14:0 1-ANP 1 0 LAH MS QC LCS B D T14:2 1-ANP LAH LCS-01 QC LCS B D T14:3 1-ANP LAH ArAm Blk-01 Sample B D T14:4 1-ANP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 1-ANP LAH Target Compound 2-ANP SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 2-ANP LAH ArAm ISTD blk Blank B D T11:4 2-ANP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 2-ANP LAH ArAm Std 3 Calibration 3 B D T12:1 2-ANP LAH ArAm Std 4 Calibration 4 B D T12:2 2-ANP LAH ArAm Std 5 Calibration 5 B D T12:3 2-ANP LAH ArAm ISTD blk Blank B D T12:4 2-ANP 1 0 LAH ArAm SS Std QC SS B D T12:5 2-ANP LAH Concal (ArAm Std 4) QC 4 B D T13:1 2-ANP LAH Concal (ArAm Std 4) QC 4 B D T10:1 2-ANP LAH Sample B D T14:0 2-ANP 1 0 LAH MS QC LCS B D T14:2 2-ANP LAH LCS-01 QC LCS B D T14:3 2-ANP LAH ArAm Blk-01 Sample B D T14:4 2-ANP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 2-ANP LAH Target Compound 4-ABP Bemder p ArAm eliq reviewed.xlsx Page 1 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 47 of 97
48 Quantitative Analysis Summary Report SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 4-ABP LAH ArAm ISTD blk Blank B D T11:4 4-ABP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 4-ABP LAH ArAm Std 3 Calibration 3 B D T12:1 4-ABP LAH ArAm Std 4 Calibration 4 B D T12:2 4-ABP LAH ArAm Std 5 Calibration 5 B D T12:3 4-ABP LAH ArAm ISTD blk Blank B D T12:4 4-ABP 1 0 LAH ArAm SS Std QC SS B D T12:5 4-ABP LAH Concal (ArAm Std 4) QC 4 B D T13:1 4-ABP LAH Concal (ArAm Std 4) QC 4 B D T10:1 4-ABP LAH Sample B D T14:0 4-ABP 1 0 LAH MS QC LCS B D T14:2 4-ABP LAH LCS-01 QC LCS B D T14:3 4-ABP LAH ArAm Blk-01 Sample B D T14:4 4-ABP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 4-ABP LAH Bemder p ArAm eliq reviewed.xlsx Page 2 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 48 of 97
49 Quantitative Analysis Calibration Report Batch Data Path D:\Data\MS2014Q3\Bender\data\sep14\Bender p0046\quantresults\bender p ArAm eli Analysis Time 9/16/ :28 AM Analyst Name EAINC\SBrown Report Time 9/16/ :29 AM Reporter Name EAINC\SBrown Last Calib Update 9/16/ :28 AM Batch State Processed T11:28: : T11:29: : T11:28: :00 Calibration Info ISTD Compound 1-ANP-d7 Calibration STD Cal Type Level Enabled Response Exp Conc RF D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC SS Target Compound 1-ANP Calibration STD Cal Type Level Enabled Response Exp Conc RF D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC SS ISTD Compound 2-ANP-d7 Calibration STD Cal Type Level Enabled Response Exp Conc RF Bemder p ArAm eliq reviewed.xlsx Page 3 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 49 of 97
Sample RM061614VG. Analytical Report ( ) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity
For the benefit of VaporFi, Inc. Sample RM061614VG Analytical Report (0614-129) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity HPLC/UV Analysis (FP02) Acetaldehyde, Crotonaldehyde,
More informationOne Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( )
One Stop DIY Shop PO Box 104 New Germany, MN 55367 Carbonyl Assay Samples Received 09/09/2014 Analysis Report (0914-72) GC/MS Analysis Pentanedione (aka Acetyl propionyl) Diacetyl Enthalpy Analytical,
More informationQuick Nic Juice. 122 Indian Springs Drive #5 Sandwich, IL Carbonyl Assay Samples Received 3/16/2015. Analysis Report ( )
Quick Nic Juice 122 Indian Springs Drive #5 Sandwich, IL 60548 Carbonyl Assay Samples Received 3/16/2015 Analysis Report (0315-538) HPLC/UV Analysis Acetoin (aka 3-Hydroxy-2-butanone) Diacetyl 2,3-Pentanedione
More informationInnokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C.
Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C. 518104 E-Cigarette Aerosol Analysis Samples Received 1/30/2015 Analysis Report
More informatione-liquid Samples Received 05/16/2014 Analysis Report ( ) GC/FID Analysis Nicotine Diethy lene glycol (DEG)
e-liquid Samples Received 05/16/2014 Analysis Report (0514-132) GC/FID Analysis Nicotine Diethy lene glycol (DEG) HBLCIUV Analysis Acetaldehyde Aceto in Diacetyl Formaldehyde Pentanedione Karl Fischer
More informationSchedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)
Schedule Assignment Due Date Draft Section of Lab Report Monday 6pm (Jan 27) Quiz for Lab 2 Peer Review of Draft Complete Lab Report 1 Tuesday 9:30am Wednesday 6pm Friday 6pm Summary of Paper 2 Monday
More informationStandard Operating Procedure for Performing a QA Review of an Aldehyde Data Batch
North Carolina Division of Air Quality Quality Assurance Project Plan 2.52 Aldehydes by TO-11a Section 4.1 Raleigh Central Office Responsibilities Aldehyde Data Review Section 2.52.4.1 Page 1 of 7 Standard
More informationCopyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction
II. Quality Control A. Introduction ENCO adheres to strict quality control practices in order to assure our clients that the data provided are accurate and reliable. We are required by the EPA to analyze
More informationANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503
ANALYTICAL REPORT Job Number: 580-5407-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager
More informationANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503
ANALYTICAL REPORT Job Number: 580-5385-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager
More informationAmerican Environmental Testing Laboratory Inc.
American Environmental Testing Laboratory Inc. 2834 & 2908 North Naomi Street Burbank, CA 91504 DOHS NO: 1541, LACSD NO: 10181 Tel: (888) 288-AETL (818) 845-8200 Fax: (818) 845-8840 www.aetlab.com Ordered
More informationSulfotepp impurities in Chlorpyrifos EC formulations
Page 1 of 16 Method DAS-AM-01-058 Sulfotepp impurities in Chlorpyrifos EC formulations A. ABSTRACT Method DAS-AM-01-058 has been validated for the analysis of the relevant impurity sulfotepp in chlorpyrifos
More informationOBJECTIVE DATA PACKAGE DELIVERABLES
PAGE: 1 of 10 OBJECTIVE This Standard Operating Procedure (SOP) describes the requirements for the analytical data packages that will be generated in association with the Stage 2 Delaware River Estuary
More information2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT January 7, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa
More informationCertificate of Analysis FINAL REPORT
[TOC_1]Cover Letter[TO Work Orders: Project: Report Date: Received Date: Turnaround Time: Phones: Fax: 6/13/2017 6/5/2017 5 workdays (562) 275-4252 (562) 921-6101 Attn: Client: P.O. #: Billing Code: DoD-ELAP
More informationalscience nvironmental aboratories, Inc.
alscience nvironmental aboratories, Inc. Page 1 of 13 June 02, 2009 Ewelina Mutkowska OTIE 317 East Main Street Ventura, CA 93001-2624 P Subject: Calscience Work Order No.: Client Reference: 09-05-2222
More informationQUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.
1 REVISOR 4740.2100 4740.2100 QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY. Subpart 1. Scope. This part applies to laboratories performing testing under the inorganic chemistry, metals,
More informationPCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD
` PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD Eric Crecelius and Lisa Lefkovitz Pacific Northwest National Laboratory Battelle Marine Sciences Laboratory 1529 West Sequim Bay Road
More informationAnalysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector
Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent Infinity LC System with Diode Array Detector Application Note Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany [mau]
More informationSTANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS
PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationSTANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS
PAGE: 1 of 18 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationANALYTICAL REPORT. Job Number: Job Description: Transform Complete
ANALYTICAL REPORT Job Number: 640-4848-1 Job Description: Transform Complete For: American Master*Tech Scientific, Inc. 1330 Thurman Street PO BOX 2539 Lodi, CA 95240 Attention: Mr. Adam Kowalczyk Chad
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- Client For: ARCADIS U.S. Inc Massena Facility, Route East Chevrolet
More informationDetermination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*
Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* EPA Method 8315A UCT Part Number: EUC1812M15 (Unendcapped C18-2000 mg/15 ml cartridge) March 2013 Method
More informationEnclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.
Environmental Conservation Laboratories, Inc. 10775 Central Port Drive Orlando FL, 32824 407.826.5314 407.850.6945 Phone: FAX: www.encolabs.com Friday, March 5, 2010 Jones Edmunds & Associates (JO005)
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0- Client For: ARCADIS U.S.
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc
More informationReview and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)
Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350) Ann Strahl Technical Support Remediation Division TCEQ 512-239-2500 astrahl@tceq.state.tx.us 1 Data
More informationMethod - Determination of aromatic amines in mainstream cigarette smoke
British American Tobacco Group Research & Development Method - Determination of aromatic amines in mainstream cigarette smoke 1 SCOPE OF APPLICATION The method is applicaple to quantitative determination
More informationVALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION
VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic
More informationMolecule Labs 780 Clark Avenue Pittsburg, CA 94565
Mlecule Labs 780 Clark Avenue Pittsburg, CA 94565 Carbnyl Assay Vn Vape Nble 0.6% Analytical Reprt (0615-572C1) GC/MS Analysis (NT225-Draft) Diacetyl 2,3-Pentanedine (aka Acetyl prpinyl) nthalpy Analytical,
More informationAldehydes/Ketones DNPH Standard
Analytical Reference Materials Aldehydes/Ketones DNPH Standard Catalog # 31808 Lot # A075429 110 Benner Circle Bellefonte, PA 16823-8812 (814) 353-1300 FOR LABORATORY USE ONLY. READ MSDS PRIOR TO USE.
More information[ a ppl ic at ion no t e ]
[ a ppl ic at ion no t e ] Fast A nalysis of A ldehydes and K etones by A C Q U I T Y U P L C Mark E. Benvenuti Waters Corporation, Milford, MA, USA INT RO DUC T ION Aldehydes and ketones are products
More informationUncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...
Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials (HPLC grade)... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation...
More informationLAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)
LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.) SOP-316 391 S. Vidal St., Sarnia, Ontario, N7T 7L1 Phone: (519) 344-4747 Fax: (519) 344-2350 E-Mail: info@lambtonscientific.com Method
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0 Client For: ARCADIS U.S. Inc
More informationMETHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS
METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,
More informationTNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4
page1 of 8 TNI Standard VOLUME 1 MODULE 4 QUALITY SYSTEMS FOR CHEMICAL TESTING SECTIONS 1.5.1 AND 1.5.2 January 2016 Description This TNI Standard has been taken through all of the voting stages and has
More informationRIGHT SOLUTIONS RIGHT PARTNER
2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT March 14, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa
More informationPA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)
Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID) Table of Contents Section 1: Summary of Method Section 2: Scope and Application Section
More informationDHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.
June 26, 2009 Charles E. Martin 11370 Breininger Road Hicksvile, OH 43526 TEL: (419) 542-6645 FAX: (419) 542-6475 Order No: 0906168 RE: Dear Charles E. Martin: DHL Analytical received 2 sample(s) on 6/18/2009
More informationQuantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector
SOP # 04/30/6 04/30/6 of 4 Mike Klasner Mike Klasner 04/30/6 Quantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector.0 PURPOSE.
More informationHow Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports
How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports Railroad Environmental Conference University of Illinois at Urbana-Champaign November 1 and 2, 2016 Erin E. Rodgers Environmental
More informationVOTING DRAFT STANDARD
page 1 of 7 VOTING DRAFT STANDARD VOLUME 1 MODULE 4 QUALITY SYSTEMS FOR CHEMICAL TESTING SECTIONS 1.5.1 AND 1.5.2 Description This Voting Draft Standard is a proposed revision of the 2009 standard (EL-
More informationAgilent MassHunter Workstation Software
Agilent MassHunter Workstation Software Quantitative Analysis Quantitation DataSet Agilent Technologies Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced in any form or by
More informationANALYTICAL REPORT. Attn: Richard Boelter
ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0- TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc
More informationTechnical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS
Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS 1.0 Purpose - This procedure specifies the required elements for the extraction and quantitation of THC,
More informationTO-15 Checklist Determination of VOCs in Air by GC-MS
LAB ID: DATE: LAB NAME: ASSESSOR NAME: Method Number: TO-15 Checklist Determination of VOCs in Air by GC-MS SOP Number: Revision Number: SOP Date: Personnel records observed: Data records observed: Revision
More informationEPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS
EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of
More informationQuality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE
Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE Use objectives: state purpose for which results will be used. Specifications: How good should the numbers be
More informationUncontrolled Copy. SOP Ethylene Glycol Quantitation by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...
Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials (HPLC grade)... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation
More informationANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington
ANALYTICAL REPORT Job Number: 460-43877-1 Job Description: 17338-TO4-2012, RACER, GM Wilmington For: Conestoga-Rovers & Associates, Inc. 2055 Niagara Falls Blvd., Suite 3 Niagara Falls, NY 14304 Attention:
More informationAppendix II- Bioanalytical Method Development and Validation
A2. Bioanalytical method development 1. Optimization of chromatographic conditions Method development and optimization of chromatographic parameters is of utmost important for validating a method in biological
More informationANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis
DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes
More informationMETHOD 8000A GAS CHROMATOGRAPHY
METHOD 8000A GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Gas chromatography is a quantitative technique useful for the analysis of organic compounds capable of being volatilized without being decomposed
More informationGC/MS Analysis Laboratory Report
Report No.: J-123456 Date: March 1, 2016 P.O. No.: PO 1234A GC/MS Analysis Laboratory Report Prepared for: Mr. Customer Name Company Name, Inc. 123 First St. Your City, State Prepared by: Bradley J. Cline
More informationTEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD
APPENDIX V TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD Validating Chromatographic Methods. By David M. Bliesner Copyright 2006 John Wiley & Sons, Inc. 159 160 APPENDIX V Title: Effective: Document No:
More informationCCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method
Rating Guide Appendix for the CCME Reference Method for the Canada-Wide Standard for Petroleum (PHC) in Soil - Tier 1 Method (Note: Checklist incorporates requirements from Dec 2000 version + Addendum
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch Table, Compound Information Setup, Calibration Curve and Globals Settings 1 MassHunter
More informationQuality Control Procedures for Graphite Furnace AAS using Avanta Software
Application Note Quality Control Procedures for Graphite Furnace AAS using Avanta Software Introduction With the arrival of quality standards in the analytical laboratory, an ever increasing emphasis is
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 55 ONTENTS 1.0 OBJETIVE 2.0 APPLIABILITY 3.0 DESRIPTION 3.1 Sample ontainers, Preservative, Storage and Holding Times 3.1.1 Objective 3.1.2 Requirements 3.1.3 Evaluation Procedure 3.1.4 Action
More informationLaboratory 101: A Guide to Understanding your Testing Laboratory
Laboratory 101: A Guide to Understanding your Testing Laboratory Jim Cronin Product Ecology Manager Environmental Monitoring and Technologies, Inc. (EMT) Morton Grove, Illinois Abstract: Laboratory 101:
More informationExtraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis
Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range
More informationALLOWAY METHOD OUTLINE
ALLOWAY METHOD OUTLINE Standard Laboratory Method SM4500-Cl -G Parameter Residual Chlorine & Free Chlorine Method DPD Colorimetric Test Kit Date Issued Originator: Section Supervisor: QA Manager Date:
More informationUncontrolled Copy. Table of Contents. 1. Principle of Assay Specimens Reagents and Materials... 3
Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation and Parameters...
More informationHach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water
Hach Method 1041 Spectrophotometric Measurement of Free Chlorine (Cl ) in Finished Drinking Water Hach Company Method 1041 Revision 1. November 015 Spectrophotometric Measurement of Free Cl in Finished
More informationPerfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM
Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),
More informationHach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis
Hach Method 1061 Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis Hach Company Method 1061 Revision 1. December 015 Organic Carbon in Finished
More informationEPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS
Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the
More informationSTANDARD OPERATING PROCEDURES
STANDARD OPERATING PROCEDURES for Spectrophotometric Measurement Chl a, Chl b, and Bulk Carotenoids using Methanol Solvent Prepared by EcoAnalysts, Inc. 1420 South Blaine Street, Suite 14 Moscow, ID 83843
More informationImpact factor: 3.958/ICV: 4.10 ISSN:
Impact factor: 3.958/ICV: 4.10 ISSN: 0976-7908 99 Pharma Science Monitor 9(4), Oct-Dec 2018 PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES Journal home page: http://www.pharmasm.com
More informationAnalytical Report
Analytical Report 386228 for Natural Soap Formulas Project Manager: Wanda Baligad Formula 206 Natural Soap Formulas 20-AUG-10 3231 NW 7th Avenue, Boca Raton, FL 33431 Ph:(561) 447-7373 Fax:(561) 447-6136
More informationMETHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS
METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8100 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH). Table 1 indicates compounds
More informationMeasurement Uncertainty: A practical guide to understanding what your results really mean.
Measurement Uncertainty: A practical guide to understanding what your results really mean. Overview General Factors Influencing Data Variability Measurement Uncertainty as an Indicator of Data Variability
More informationKSA Environmental Laboratory Inc.
September 07, 2007 KSA Environmental Laboratory Inc. Amerigrow Recycling Attn: Orlando D. Pagan 10320 West Atlantic Ave Delray Beach, FL 33446 RE: Mulch Metals KSA Workorder: Q006081 Dear Orlando D. Pagan,
More informationEPAs New MDL Procedure What it Means, Why it Works, and How to Comply
EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows TestAmerica Inc. 1 A Revision to the Method Detection Limit EPA published a revision to the 40 CFR Part 136 MDL procedure
More informationAnalysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research
Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Heather A Brown, 1 Claudia Rossi, 2 and Lisa J Calton 1 1 Waters Corporation, Wilmslow, UK 2
More informationALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011
ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011 1,2-DIBROMOETHANE (EDB) AND 1,2-DIBROMO-3-CHLOROPROPANE (DBCP) IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY SOP #: 504.1 Revision 1.1,
More informationALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)
Eight Walkup Drive Westborough, Massachusetts 01581-1019 (508) 898-9220 www.alphalab.com MA:M-MA086 NH:200301-A CT:PH-0574 ME:MA086 RI:65 NY:11148 NJ:MA935 Army:USACE CERTIFICATE OF ANALYSIS Client: Fulham
More informationLaboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.
NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION OFFICE OF QUALITY ASSURANCE ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM ON-SITE LABORATORY EVALUATION RADIOCHEMISTRY PROCEDURES Gross Alpha-Gross Beta
More informationTotal Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector
Title: TPH-SHC Page 1 of 18 Total Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector References: USEPA, Method 8015D Nonhalogenated Organics Using GC/FID, in Test Methods
More informationDirect Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry
Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry NOTICE: This method has been developed by the EURL-CEFAO using the facilities available in its laboratories.
More information~ ALG ANALYTICAL LABORATORY GROUP
August 19, 2016 Doug Pigman Greater Albany Public Schools 3610 Grand Prairie Albany, OR 97322 TEL: (541) 967-4513 FAX RE: Waverly Retest Order No.: 1608769 Dear Doug Pigman: Analytical Laboratory Group
More informationIf you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS
#=CL# LIMS USE: FR - JILL LAVOIE LIMS OBJECT ID: July 16, 2015 Jill Lavoie Merrimack Village District - UCMR3 2 Greens Pond Road Merrimack, NH 03054 RE: Dear Jill Lavoie: Enclosed are the analytical results
More informationTechnical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC
Technical Procedure for Concentration Determination of 1.0 Purpose This procedure specifies the required elements for the preparation and use of the Agilent 1100/1200 series High Performance Liquid Chromatograph
More informationACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)
2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 Analytical Report November 19, 2004 Report to: Debbie Furlow 602 Lehmberg Road Columbus, MS 39702 Bill to: Accounts Payable PO Box 2487 Columbus,
More informationAPPENDIX D Laboratory Analytical Reports
Allied Aviation Initial Abatement Report, Arlington, VA December 4, 2015 Amec Foster Wheeler Project 37650016 APPENDIX D Laboratory Analytical Reports #=CL# LIMS USE: FR - JOHN MITTAUER LIMS OBJECT ID:
More informationRevision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:
ALLOWAY METHOD OUTLINE Standard Laboratory Method: SM Parameter: Methylene Blue Method: Colorimetric Reporting Level: Reference: 0.05 mg/l Standard Methods for the Examination Of Water and Wastewater;
More informationMethod Validation and Accreditation
SELAMAT Mycotoxins Workshop China, 11-15th December 2006 Method Validation and Accreditation Dr Hamide Z Şenyuva Senior Research Scientist TÜBİTAK-ATAL, TURKEY hamide.senyuva@tubitak.gov.tr SELAMAT Mycotoxins
More informationAppendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997
Appendix A Glossary of Definitions, Acronyms, Abbreviations and Symbols March 1997 Glossary Of Definitions, Acronyms, Abbreviations And Symbols 1.0 Standard Acronyms, Abbreviations, And Symbols 1.1 Units
More informationTechnical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis
Technical Procedure for Solid Phase Extraction of THC and THC-COOH 1.0 Purpose - This procedure specifies the required elements for the extraction of THC and THC-COOH using United Technologies Styre Screen
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationDecember 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:
December 30, 2018 ENVIRONMENTAL AGRICULTURAL Meadowlark Ranches Mutual Water Co. Lab ID : SP 1816365 Attn: Mike Hadley P.O. Box 606 Santa Ynez, CA 93460-0606 Customer : 2-21676 Laboratory Report This Page
More information7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.
7. Stability indicating analytical method development and validation of and in capsule dosage form by HPLC. 7.1 INSTRUMENTS AND MATERIALS USED 7.1.1 INSTRUMENTS 1. Shimadzu LC-2010 CHT with liquid chromatograph
More informationQualification Specifications for Agilent 1100/1200 HPLC Systems
Agilent 1100/1200 HPLC Systems 35 Vantage Point Drive, Rochester NY 14624 Phone: 800-828-1470 Fax: 800-395-0543 Transcat.com Test Set Points/ Range Acceptance Criteria Flow Rate Accuracy and Precision
More informationUncontrolled Copy. Table of Contents. 1. Introduction and Principle of Assay Specimens Reagents and Materials...
Table of Contents 1. Introduction and Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation
More informationFigure 1. Structures for Vitamin B2 and Vitamin B1.
CH 461 & CH 461H F 15 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment
More informationVOC TEST REPORT CDPH
Euro Trade Flooring SL. Pol. Ind. Can Estella c/galileo no. 11 08635 Sant Esteve Sesrovires BARCELONA SPAIN Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing
More informationEPA TO-17 Volatile Organic Compounds
EPA TO-17 Volatile Organic Compounds Method TO-17 is used to analyze samples for volatile organic compounds collected on multi-bed sorbent tubes, which are thermally desorbed and cryo-focused on the capillary
More informationAnalysis of BTEX in Natural Water with SPME
Analysis of BTEX in Natural Water with SPME Application Note Environmental Author Giordano Vassalli Sezione Protezione Aria Introduction Benzene, toluene, ethylbenzene and xylene (BTEX) isomers are monocyclic
More information