Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde

Size: px
Start display at page:

Download "Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde"

Transcription

1 For the benefit of VaporFi, Inc. Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde GC/MS/MS Analysis 1-Aminonaphthalene, 2-Aminonaphthalene, 4-Aminobiphenyl Enthalpy Analytical, Inc. Phone: (919) / Fax: (919) / Capitola Drive Durham, NC

2 I certify that to the best of my knowledge all analytical data presented in this report: Have been checked for completeness Are accurate, error-free, and legible Have been conducted in accordance with approved protocol, and that all deviations and analytical problems are summarized in the appropriate narrative(s) This analytical report was prepared in Portable Document Format (.PDF) and contains 97 pages. Report Issued: 09/16/2014 EA# B Page 2 of 97

3 Summary of Results EA# B Page 3 of 97

4 Report for: For the benefit of VaporFi, Inc. Project Code: Client Project: RM02 & HPHC Testing Project Start Date: 08/07/2014 Sample Type: eliquid Analysis Method: ENT301 Enthalpy Code Client Code Dilution Factor Acetaldehyde (ug/ml) Acrolein (ug/ml) Crotonaldehyd e (ug/ml) Formaldehyde (ug/ml) RM < 1.07 ND < 1.09 ND 10.2 ND: Not Detected; analytes not detected above the MDL Compound / Dilution MS Catch Spike Amnt Native Amnt Recovery Sample ID Factor (ug) (ug) (ug) % Acetaldehyde MS % Acrolein MS % Crotonaldehyde MS % Formaldehyde MS % carbo.xlsx, carb Page 1 of 1 EA# B Page 4 of 97 09/16/ :03

5 Report for: For the benefit of VaporFi, Inc. Project Code: Client Project: RM02 & HPHC Testing Project Start Date: 08/07/2014 Sample Type: eliquid Analysis Method: GC/MS/MS Enthalpy Code Client Code 1-ANP (ng/ml) 2-ANP (ng/ml) 4-ABP (ng/ml) an4 (ug/ml) RM < 1.81 ND < 1.80 ND < ND < 1.10 ND ND: Not Detected; analytes not detected above the minimum detection limit. Compound / MS Sample Spiked Native Recovery Sample ID (ng) (ng) (ng) % 1-ANP MS % 2-ANP MS % 4-ABP MS % ND: Not Detected; analytes not detected above the minimum detection limit. Analyte Code 1-ANP: 1-Aminonaphthalene 2-ANP: 2-Aminonaphthalene 4-ABP: 4-Aminobiphenyl B eliq ArAm.xlsx, AA Page 1 of 1 EA# B Page 5 of 97 09/16/ :39

6 Narrative Summary EA# B Page 6 of 97

7 Enthalpy Analytical Narrative Summary Company For the benefit of VaporFi, Inc. Eliquid samples Analyst WJG / ETA Job # Parameters HPLC/UV Analysis # Samples 1 Custody Analysis Summer Mims received the samples on 8/7/14 after being relinquished by for the benefit of VaporFi, Inc. The samples were received at ambient temperature in good condition. Prior to, during, and after analysis, the samples were kept under lock with access only to authorized personnel by Enthalpy Analytical, Inc. The samples were analyzed for acetaldehyde, acrolein, crotonaldehyde, and formaldehyde following the analytical procedures in Enthalpy SOP ENT301. The Agilent Model 1100, High Performance Liquid Chromatograph "Groucho" was equipped with an Ultraviolet (UV) Detector operating at 365 nm and an appropriate column. Calibration QC Notes The calibration curve is located in the Carbonyls Raw Data section of this report. Acetaldehyde, acrolein, formaldehyde, and crotonaldehyde were not detected in the blank at levels above the minimum detection limit (MDL). A matrix spike (MS) was prepared using an aliquot of the sample. The recovery values were within 30% of the expected values. Reporting Notes The reported concentrations (ug/ml) were calculated by multiplying the diluted results by the dilution factor. The data in the Raw Data section of the report are diluted and have not been adjusted for the dilution factor. The results presented in this report are representative of the sample as provided to the laboratory. EA# B Page 7 of 97

8 Enthalpy Analytical Narrative Summary Company For the benefit of VaporFi, Inc. Eliquid samples Analyst SSB Job # Parameters GC/MS/MS Analysis # Samples 1 Custody Summer Mims received the samples on 8/7/14 after being relinquished by for the benefit of VaporFi, Inc. The samples were received at ambient temperature in good condition. Prior to, during, and after analysis, the samples were kept under lock with access only to authorized personnel by Enthalpy Analytical, Inc. Analysis The liquid samples were analyzed for 1-aminonaphthalene (1-ANP), 2- aminonaphthalene (2-ANP), and 4-aminobiphenyl (1-ABP) following the general analytical procedures for GC/MS analyses and Enthalpy SOP ENT213. Aliquots of 0.5 ml of each sample were combined with 4.5mL of HCl and 0.1mL of internal standard. The Agilent Model 7890A Gas Chromatograph Bender was coupled to an Agilent Model 5975 Mass Selective Detector and was fitted with an appropriate column. Calibration QC Notes Refer to the Aromatic Amines Raw Data section of this report for chromatograms. The target analytes were not detected in the laboratory blank or the sample above the MDL. A matrix spike (MS) was prepared using an aliquot of the sample. The recovery values were within 15% of the expected values Reporting Notes The reported < concentrations were calculated by dividing the MDL ng by the sample aliquot volume (0.5 ml) used for the analysis. The chromatograms in the Raw Data section of the report present the results in units of ng. The results presented in this report are representative of the samples as provided to the laboratory. EA# B Page 8 of 97

9 General Reporting Notes The following are general reporting notes that are applicable to all Enthalpy Analytical, Inc. data reports, unless specifically noted otherwise. Any analysis which refers to the method as Type represents a planned deviation from the reference method. For instance a Hydrogen Sulfide assay from a Tedlar bag would be labeled as EPA Method 16-Type because Tedlar bags are not mentioned as one of the collection options in EPA Method 16. The acronym MDL represents the Minimum Detection Limit. Below this value the laboratory cannot determine the presence of the analyte of interest reliably. The acronym LOQ represents the Limit of Quantification. Below this value the laboratory cannot quantitate the analyte of interest within the criteria of the method. The acronym ND following a value indicates a non-detect or analytical result below the MDL. The letter J in the Qualifier or Flag column in the results indicates that the value is between the MDL and the LOQ. The laboratory can positively identify the analyte of interest as present, but the value should be considered an estimate. The letter E in the Qualifier or Flag column indicates an analytical result exceeding 100% of the highest calibration point. The associated value should be considered as an estimate. The acronym DF represents Dilution Factor. This number represents dilution of the sample during the preparation and/or analysis process. The analytical result taken from a laboratory instrument is multiplied by the DF to determine the final undiluted sample results. The addition of MS to the Sample ID represents a Matrix Spike. An aliquot of an actual sample is spiked with a known amount of analyte so that a percent recovery value can be determined. The MS analysis indicates what effect the sample matrix may have on the target analyte, i.e. whether or not anything in the sample matrix interferes with the analysis of the analyte(s). The addition of MSD to the Sample ID represents a Matrix Spike Duplicate. Prepared in the same manner as a MS, the use of duplicate matrix spikes allows further confirmation of laboratory quality by showing the consistency of results gained by performing the same steps multiple times. The addition of LD to the Sample ID represents a Laboratory Duplicate. The analyst prepares an additional aliquot of sample for testing and the results of the duplicate analysis are compared to the initial result. The result should have a difference value of within 10% of the initial result (if the results of the original analysis are greater than the LOQ). The addition of AD to the Sample ID represents an Alternate Dilution. The analyst prepares an additional aliquot at a different dilution factor (usually double the initial factor). This analysis helps confirm that no additional compound is present and coeluting or sharing absorbance with the analyte of interest, as they would have a different response/absorbance than the analyte of interest. EA# B Page 9 of 97

10 General Reporting Notes (continued) The Sample ID LCS represents a Laboratory Control Sample. Clean matrix, similar to the client sample matrix, prepared and analyzed by the laboratory using the same reagents, spiking standards and procedures used for the client samples. The LCS is used to assess the control of the laboratory s analytical system. Whenever spikes are prepared for our client projects, two spikes are retained as LCSs. The LCSs are labeled with the associated project number and kept in-house at the appropriate temperature conditions. When the project samples are received for analysis, the LCSs are analyzed to confirm that the analyte could be recovered from the media, separate from the samples which were used on the project and which may have been affected by source matrix, sample collection and/or sample transport. Significant Figures: Where the reported value is much greater than unity (1.00) in the units expressed, the number is rounded to a whole number of units, rather than to 3 significant figures. For example, a value of 10, ug catch is rounded to 10,456 ug. There are five significant digits displayed, but no confidence should be placed on more than two significant digits. Manual Integration: The data systems used for processing will flag manually integrated peaks with an M. There are several reasons a peak may be manually integrated. These reasons will be identified by the following two letter designations on sample chromatograms, if provided in the report. The peak was not integrated by the software NI, the peak was integrated incorrectly by the software II or the wrong peak was integrated by the software WP. These codes will accompany the analyst s manual integration stamp placed next to the compound name on the chromatogram. EA# B Page 10 of 97

11 Sample Custody Record EA# B Page 11 of 97

12 For the benefit of VaporFi, Inc. EA# B Page 12 of 97

13 EA# B Page 13 of 97 Raw Data

14 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D /4/2014 1:19:20 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :37:58 PM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Sample Location: 51 Injection volume: Injection: 1 of 1 File_Version 8 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde VB ug/ml Acrolein ug/ml Crotonaldehyde ug/ml 4 cmpds GoodCat [Rev. 2] Printed: 09/11/ :09:06 Page 1 of 1 EA# B Page 14 of 97

15 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D DNPH Blank 9/4/2014 2:21:39 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Sample Location: 53 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde ug/ml Acetaldehyde ug/ml Acrolein ug/ml Crotonaldehyde ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 2 of 6 EA# B Page 15 of 97

16 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #4 9/4/2014 6:30:31 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :11:13 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein BB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 3 of 6 EA# B Page 16 of 97

17 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO127\ D Sample name: HPLC-STDs014 #4 File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/5/ :52:29 AM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/2014 3:20:18 PM Instrument: Sequence_Name GROUCHO127 Acq. operator: Wendy Gardow Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein VB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 4 of 6 EA# B Page 17 of 97

18 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO127\ D MS 9/5/ :25:58 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/2014 3:20:18 PM Groucho GROUCHO127 Wendy Gardow Enthalpy Analytical, Inc. Sample type: Sample Location: 72 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde VV ug/ml Acetaldehyde BB ug/ml Acrolein VV ug/ml Crotonaldehyde VB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 5 of 6 EA# B Page 18 of 97

19 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO127\ D HPLC-STDs014 #4 9/5/ :57:09 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/2014 3:20:18 PM Groucho GROUCHO127 Wendy Gardow Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 2 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Acrolein VB ug/ml Crotonaldehyde BB ug/ml 4 cmpds GoodCat [Rev. 1] Printed: 09/05/ :29:29 Page 6 of 6 EA# B Page 19 of 97

20 Sequence Summary Report Sequence_AcquiredBy Sequence_AcquiredDate Sequence_Name Sequence_LastModifiedBy Erik Alvarez 9/3/2014 3:56:35 PM GROUCHO126 Wendy Gardow Sequence_Ver 6 Name Acetaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Acetoin Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Name Acetone Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 20 of 97

21 Sequence Summary Report Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Acrolein Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Crotonaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Diacetyl Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 21 of 97

22 Sequence Summary Report Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Name Formaldehyde Sample_ID Sample_Type Vial RT Area Dil Tag Amount Unit % of Amt Tag HPLC-STDs014 #1 Calibration ug/ml HPLC-STDs014 #2 Calibration ug/ml HPLC-STDs014 #3 Calibration ug/ml HPLC-STDs014 #4 Calibration ug/ml HPLC-STDs014 #5 Calibration ug/ml HPLC-STDs014 #6 Calibration ug/ml HPLC-STDs014 #7 Calibration ug/ml HPLC-STDs015 #1 Calibration ug/ml NaN HPLC-STDs015 #2 Calibration ug/ml NaN HPLC-STDs015 #3 Calibration ug/ml NaN HPLC-STDs015 #4 Calibration ug/ml NaN HPLC-STDs015 #5 Calibration ug/ml NaN HPLC-STDs015 #6 Calibration ug/ml NaN HPLC-STDs015 #7 Calibration ug/ml NaN Name Pentanedione Sample_ID Sample_Type Vial RT Area Dil Tag Amt Amount Unit % of Tag HPLC-STDs014 #1 Calibration ug/ml NaN HPLC-STDs014 #2 Calibration ug/ml NaN HPLC-STDs014 #3 Calibration ug/ml NaN HPLC-STDs014 #4 Calibration ug/ml NaN HPLC-STDs014 #5 Calibration ug/ml NaN HPLC-STDs014 #6 Calibration ug/ml NaN HPLC-STDs014 #7 Calibration ug/ml NaN HPLC-STDs015 #1 Calibration ug/ml HPLC-STDs015 #2 Calibration ug/ml HPLC-STDs015 #3 Calibration ug/ml HPLC-STDs015 #4 Calibration ug/ml HPLC-STDs015 #5 Calibration ug/ml HPLC-STDs015 #6 Calibration ug/ml HPLC-STDs015 #7 Calibration ug/ml Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 22 of 97

23 Sequence Summary Report Sequence_AcquiredBy Sequence_AcquiredDate Sequence_Name Sequence_LastModifiedBy Erik Alvarez 9/3/2014 3:56:35 PM GROUCHO126 Wendy Gardow Sequence_Ver 6 Name Acetaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acetoin Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acetone Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Acrolein Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Crotonaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Diacetyl Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Formaldehyde Sample_ID Sample_Type Vial RT Area Dil Amount Unit HPLC-STDs014 #SS Control ug/ml HPLC-STDs014 #RB Control ug/ml HPLC-STDs015 #SS Control ug/ml HPLC-STDs015 #RB Control ug/ml Name Pentanedione Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 23 of 97

24 Sequence Summary Report Sample_ID HPLC-STDs014 #SS HPLC-STDs014 #RB Sample_Type Control Control Vial 8 9 RT Area Dil 1 1 Amount Unit ug/ml ug/ml HPLC-STDs015 #SS HPLC-STDs015 #RB Control Control ug/ml ug/ml Compound Acetaldehyde : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Acetoin : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 24 of 97

25 Sequence Summary Report Compound Acetone : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Acrolein : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 25 of 97

26 Sequence Summary Report Compound Crotonaldehyde : Signal: VWD1A Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: Compound Diacetyl : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 26 of 97

27 Sequence Summary Report Compound Formaldehyde : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Compound Pentanedione : Signal: Exp. RT: Corr Coeff : Residual: RF RSD%: Formula: y = ax + b a: b: c: d: VWD1A Summary with % Tag [Rev. 3] Printed: 09/05/ :14:06 Page 1 of 1 EA# B Page 27 of 97

28 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #1 9/3/2014 3:58:25 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :13:15 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 1 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde MM ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 1 of 18 EA# B Page 28 of 97

29 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #2 9/3/2014 4:29:31 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 2 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde MM ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 2 of 18 EA# B Page 29 of 97

30 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #3 9/3/2014 5:00:43 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 3 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 3 of 18 EA# B Page 30 of 97

31 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #4 9/3/2014 5:31:49 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 4 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 4 of 18 EA# B Page 31 of 97

32 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #5 9/3/2014 6:03:16 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 5 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 5 of 18 EA# B Page 32 of 97

33 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #6 9/3/2014 6:34:26 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 6 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 6 of 18 EA# B Page 33 of 97

34 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #7 9/3/2014 7:05:33 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 7 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BV ug/ml Acrolein VB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 7 of 18 EA# B Page 34 of 97

35 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #SS 9/3/2014 7:36:42 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 8 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde BB ug/ml Acetaldehyde BB ug/ml Diacetyl ug/ml Acetone BB ug/ml Acrolein BB ug/ml Pentanedione ug/ml Crotonaldehyde BB ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 8 of 18 EA# B Page 35 of 97

36 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs014 #RB 9/3/2014 8:07:53 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 9 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 9 of 18 EA# B Page 36 of 97

37 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #1 9/3/2014 8:39:04 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 91 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BB ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 10 of 18 EA# B Page 37 of 97

38 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #2 9/3/2014 9:10:12 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 92 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BB ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 11 of 18 EA# B Page 38 of 97

39 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #3 9/3/2014 9:41:22 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 93 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 12 of 18 EA# B Page 39 of 97

40 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #4 9/3/ :12:30 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 94 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BB ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 13 of 18 EA# B Page 40 of 97

41 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO126\ D Sample name: HPLC-STDs015 #5 File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/3/ :43:40 PM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/ :10:52 AM Instrument: Sequence_Name GROUCHO126 Acq. operator: Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 95 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 14 of 18 EA# B Page 41 of 97

42 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #6 9/3/ :14:45 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 96 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione VV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 15 of 18 EA# B Page 42 of 97

43 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #7 9/3/ :45:55 PM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Calibration Location: 97 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl BB ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione VV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 16 of 18 EA# B Page 43 of 97

44 Chromatogram Report Data file: Sample name: File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: Acq. method: Analysis method: Last changed: Instrument: Sequence_Name Acq. operator: C:\Chem32\1\DATA\GROUCHO126\ D HPLC-STDs015 #SS 9/4/ :17:06 AM ELIQUID_BC_NEW.M GROUCHO126.M 9/5/ :10:52 AM Groucho GROUCHO126 Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 98 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin BV ug/ml Formaldehyde ug/ml Acetaldehyde VB ug/ml Diacetyl BB ug/ml Acetone BB ug/ml Acrolein ug/ml Pentanedione BV ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 17 of 18 EA# B Page 44 of 97

45 Chromatogram Report Data file: C:\Chem32\1\DATA\GROUCHO126\ D Sample name: HPLC-STDs015 #RB File_Location \TSC Data\2014\Groucho\Quarter 3 Injection date: 9/4/ :48:09 AM Acq. method: ELIQUID_BC_NEW.M Analysis method: GROUCHO126.M Last changed: 9/5/ :10:52 AM Instrument: Sequence_Name GROUCHO126 Acq. operator: Erik Alvarez Enthalpy Analytical, Inc. Sample type: Control Location: 99 Injection volume: Injection: 1 of 1 File_Version 7 Name Peak_Type RT [min] Area Dil ug/ml Sample_Amount Units Acetoin ug/ml Formaldehyde ug/ml Acetaldehyde ug/ml Diacetyl ug/ml Acetone ug/ml Acrolein ug/ml Pentanedione ug/ml Crotonaldehyde ug/ml all carbs [Rev. 3] Printed: 09/05/ :18:40 Page 18 of 18 EA# B Page 45 of 97

46 EA# B Page 46 of 97 Raw Data

47 Quantitative Analysis Summary Report Batch Data Path D:\Data\MS2014Q3\Bender\data\sep14\Bender p0046\quantresults\bender p ArAm eliq.batch.bin Analysis Time 9/16/ :28 AM Analyst Name EAINC\SBrown Report Time 9/16/ :29 AM Reporter Name EAINC\SBrown Last Calib Update 9/16/ :28 AM Batch State Processed T11:28: : T11:29: : T11:28: :00 Quantitation Results Target Compound 1-ANP SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 1-ANP LAH ArAm ISTD blk Blank B D T11:4 1-ANP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 1-ANP LAH ArAm Std 3 Calibration 3 B D T12:1 1-ANP LAH ArAm Std 4 Calibration 4 B D T12:2 1-ANP LAH ArAm Std 5 Calibration 5 B D T12:3 1-ANP LAH ArAm ISTD blk Blank B D T12:4 1-ANP 1 0 LAH ArAm SS Std QC SS B D T12:5 1-ANP LAH Concal (ArAm Std 4) QC 4 B D T13:1 1-ANP LAH Concal (ArAm Std 4) QC 4 B D T10:1 1-ANP LAH Sample B D T14:0 1-ANP 1 0 LAH MS QC LCS B D T14:2 1-ANP LAH LCS-01 QC LCS B D T14:3 1-ANP LAH ArAm Blk-01 Sample B D T14:4 1-ANP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 1-ANP LAH Target Compound 2-ANP SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 2-ANP LAH ArAm ISTD blk Blank B D T11:4 2-ANP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 2-ANP LAH ArAm Std 3 Calibration 3 B D T12:1 2-ANP LAH ArAm Std 4 Calibration 4 B D T12:2 2-ANP LAH ArAm Std 5 Calibration 5 B D T12:3 2-ANP LAH ArAm ISTD blk Blank B D T12:4 2-ANP 1 0 LAH ArAm SS Std QC SS B D T12:5 2-ANP LAH Concal (ArAm Std 4) QC 4 B D T13:1 2-ANP LAH Concal (ArAm Std 4) QC 4 B D T10:1 2-ANP LAH Sample B D T14:0 2-ANP 1 0 LAH MS QC LCS B D T14:2 2-ANP LAH LCS-01 QC LCS B D T14:3 2-ANP LAH ArAm Blk-01 Sample B D T14:4 2-ANP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 2-ANP LAH Target Compound 4-ABP Bemder p ArAm eliq reviewed.xlsx Page 1 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 47 of 97

48 Quantitative Analysis Summary Report SampleName Sample Type LevelName Data File AcqDateTime Compound Exp Conc (ng) Dilution Final Conc (ng) Accuracy 2nd An. Review toluene blk DoubleBlank B D T11:3 4-ABP LAH ArAm ISTD blk Blank B D T11:4 4-ABP 1 0 LAH ArAm Std 1 Calibration 1 B D T11:5 4-ABP LAH ArAm Std 3 Calibration 3 B D T12:1 4-ABP LAH ArAm Std 4 Calibration 4 B D T12:2 4-ABP LAH ArAm Std 5 Calibration 5 B D T12:3 4-ABP LAH ArAm ISTD blk Blank B D T12:4 4-ABP 1 0 LAH ArAm SS Std QC SS B D T12:5 4-ABP LAH Concal (ArAm Std 4) QC 4 B D T13:1 4-ABP LAH Concal (ArAm Std 4) QC 4 B D T10:1 4-ABP LAH Sample B D T14:0 4-ABP 1 0 LAH MS QC LCS B D T14:2 4-ABP LAH LCS-01 QC LCS B D T14:3 4-ABP LAH ArAm Blk-01 Sample B D T14:4 4-ABP 1 0 LAH Concal (ArAm Std 4) QC 4 B D T14:5 4-ABP LAH Bemder p ArAm eliq reviewed.xlsx Page 2 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 48 of 97

49 Quantitative Analysis Calibration Report Batch Data Path D:\Data\MS2014Q3\Bender\data\sep14\Bender p0046\quantresults\bender p ArAm eli Analysis Time 9/16/ :28 AM Analyst Name EAINC\SBrown Report Time 9/16/ :29 AM Reporter Name EAINC\SBrown Last Calib Update 9/16/ :28 AM Batch State Processed T11:28: : T11:29: : T11:28: :00 Calibration Info ISTD Compound 1-ANP-d7 Calibration STD Cal Type Level Enabled Response Exp Conc RF D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC SS Target Compound 1-ANP Calibration STD Cal Type Level Enabled Response Exp Conc RF D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataQC D:\Data\MS2014Q3\Bender\dataCalibration D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC LCS D:\Data\MS2014Q3\Bender\dataQC SS ISTD Compound 2-ANP-d7 Calibration STD Cal Type Level Enabled Response Exp Conc RF Bemder p ArAm eliq reviewed.xlsx Page 3 of 50 Printed at: 11:38 AM on: 9/16/2014 EA# B Page 49 of 97

Sample RM061614VG. Analytical Report ( ) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity

Sample RM061614VG. Analytical Report ( ) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity For the benefit of VaporFi, Inc. Sample RM061614VG Analytical Report (0614-129) GC/FID Analysis (RM01 & RM02) Diethylene glycol Vegetable glycerin Purity HPLC/UV Analysis (FP02) Acetaldehyde, Crotonaldehyde,

More information

One Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( )

One Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( ) One Stop DIY Shop PO Box 104 New Germany, MN 55367 Carbonyl Assay Samples Received 09/09/2014 Analysis Report (0914-72) GC/MS Analysis Pentanedione (aka Acetyl propionyl) Diacetyl Enthalpy Analytical,

More information

Quick Nic Juice. 122 Indian Springs Drive #5 Sandwich, IL Carbonyl Assay Samples Received 3/16/2015. Analysis Report ( )

Quick Nic Juice. 122 Indian Springs Drive #5 Sandwich, IL Carbonyl Assay Samples Received 3/16/2015. Analysis Report ( ) Quick Nic Juice 122 Indian Springs Drive #5 Sandwich, IL 60548 Carbonyl Assay Samples Received 3/16/2015 Analysis Report (0315-538) HPLC/UV Analysis Acetoin (aka 3-Hydroxy-2-butanone) Diacetyl 2,3-Pentanedione

More information

Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C.

Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C. Innokin Technology Co., Ltd. Building 6, XinXinTian Industrial Park, Xinsha Road Shajing Baoan District, Shenzhen, China P.R.C. 518104 E-Cigarette Aerosol Analysis Samples Received 1/30/2015 Analysis Report

More information

e-liquid Samples Received 05/16/2014 Analysis Report ( ) GC/FID Analysis Nicotine Diethy lene glycol (DEG)

e-liquid Samples Received 05/16/2014 Analysis Report ( ) GC/FID Analysis Nicotine Diethy lene glycol (DEG) e-liquid Samples Received 05/16/2014 Analysis Report (0514-132) GC/FID Analysis Nicotine Diethy lene glycol (DEG) HBLCIUV Analysis Acetaldehyde Aceto in Diacetyl Formaldehyde Pentanedione Karl Fischer

More information

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3) Schedule Assignment Due Date Draft Section of Lab Report Monday 6pm (Jan 27) Quiz for Lab 2 Peer Review of Draft Complete Lab Report 1 Tuesday 9:30am Wednesday 6pm Friday 6pm Summary of Paper 2 Monday

More information

Standard Operating Procedure for Performing a QA Review of an Aldehyde Data Batch

Standard Operating Procedure for Performing a QA Review of an Aldehyde Data Batch North Carolina Division of Air Quality Quality Assurance Project Plan 2.52 Aldehydes by TO-11a Section 4.1 Raleigh Central Office Responsibilities Aldehyde Data Review Section 2.52.4.1 Page 1 of 7 Standard

More information

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction II. Quality Control A. Introduction ENCO adheres to strict quality control practices in order to assure our clients that the data provided are accurate and reliable. We are required by the EPA to analyze

More information

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503 ANALYTICAL REPORT Job Number: 580-5407-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager

More information

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503 ANALYTICAL REPORT Job Number: 580-5385-2 Job Description: Old Douglas Harbor For: PND Engineers, Inc. 1506 West 36th Ave. Anchorage, AK 99503 Attention: Ms. Jennifer Lundberg Katie Downie Project Manager

More information

American Environmental Testing Laboratory Inc.

American Environmental Testing Laboratory Inc. American Environmental Testing Laboratory Inc. 2834 & 2908 North Naomi Street Burbank, CA 91504 DOHS NO: 1541, LACSD NO: 10181 Tel: (888) 288-AETL (818) 845-8200 Fax: (818) 845-8840 www.aetlab.com Ordered

More information

Sulfotepp impurities in Chlorpyrifos EC formulations

Sulfotepp impurities in Chlorpyrifos EC formulations Page 1 of 16 Method DAS-AM-01-058 Sulfotepp impurities in Chlorpyrifos EC formulations A. ABSTRACT Method DAS-AM-01-058 has been validated for the analysis of the relevant impurity sulfotepp in chlorpyrifos

More information

OBJECTIVE DATA PACKAGE DELIVERABLES

OBJECTIVE DATA PACKAGE DELIVERABLES PAGE: 1 of 10 OBJECTIVE This Standard Operating Procedure (SOP) describes the requirements for the analytical data packages that will be generated in association with the Stage 2 Delaware River Estuary

More information

2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT January 7, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa

More information

Certificate of Analysis FINAL REPORT

Certificate of Analysis FINAL REPORT [TOC_1]Cover Letter[TO Work Orders: Project: Report Date: Received Date: Turnaround Time: Phones: Fax: 6/13/2017 6/5/2017 5 workdays (562) 275-4252 (562) 921-6101 Attn: Client: P.O. #: Billing Code: DoD-ELAP

More information

alscience nvironmental aboratories, Inc.

alscience nvironmental aboratories, Inc. alscience nvironmental aboratories, Inc. Page 1 of 13 June 02, 2009 Ewelina Mutkowska OTIE 317 East Main Street Ventura, CA 93001-2624 P Subject: Calscience Work Order No.: Client Reference: 09-05-2222

More information

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY. 1 REVISOR 4740.2100 4740.2100 QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY. Subpart 1. Scope. This part applies to laboratories performing testing under the inorganic chemistry, metals,

More information

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD ` PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD Eric Crecelius and Lisa Lefkovitz Pacific Northwest National Laboratory Battelle Marine Sciences Laboratory 1529 West Sequim Bay Road

More information

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent Infinity LC System with Diode Array Detector Application Note Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany [mau]

More information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS PAGE: 1 of 14 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY CONTENTS 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS PAGE: 1 of 18 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

ANALYTICAL REPORT. Job Number: Job Description: Transform Complete

ANALYTICAL REPORT. Job Number: Job Description: Transform Complete ANALYTICAL REPORT Job Number: 640-4848-1 Job Description: Transform Complete For: American Master*Tech Scientific, Inc. 1330 Thurman Street PO BOX 2539 Lodi, CA 95240 Attention: Mr. Adam Kowalczyk Chad

More information

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- Client For: ARCADIS U.S. Inc Massena Facility, Route East Chevrolet

More information

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV* EPA Method 8315A UCT Part Number: EUC1812M15 (Unendcapped C18-2000 mg/15 ml cartridge) March 2013 Method

More information

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010. Environmental Conservation Laboratories, Inc. 10775 Central Port Drive Orlando FL, 32824 407.826.5314 407.850.6945 Phone: FAX: www.encolabs.com Friday, March 5, 2010 Jones Edmunds & Associates (JO005)

More information

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0- Client For: ARCADIS U.S.

More information

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc

More information

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350) Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350) Ann Strahl Technical Support Remediation Division TCEQ 512-239-2500 astrahl@tceq.state.tx.us 1 Data

More information

Method - Determination of aromatic amines in mainstream cigarette smoke

Method - Determination of aromatic amines in mainstream cigarette smoke British American Tobacco Group Research & Development Method - Determination of aromatic amines in mainstream cigarette smoke 1 SCOPE OF APPLICATION The method is applicaple to quantitative determination

More information

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION Andrew J. Aubin and Tanya L. Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Benzocaine (4-Aminobenzoic

More information

Molecule Labs 780 Clark Avenue Pittsburg, CA 94565

Molecule Labs 780 Clark Avenue Pittsburg, CA 94565 Mlecule Labs 780 Clark Avenue Pittsburg, CA 94565 Carbnyl Assay Vn Vape Nble 0.6% Analytical Reprt (0615-572C1) GC/MS Analysis (NT225-Draft) Diacetyl 2,3-Pentanedine (aka Acetyl prpinyl) nthalpy Analytical,

More information

Aldehydes/Ketones DNPH Standard

Aldehydes/Ketones DNPH Standard Analytical Reference Materials Aldehydes/Ketones DNPH Standard Catalog # 31808 Lot # A075429 110 Benner Circle Bellefonte, PA 16823-8812 (814) 353-1300 FOR LABORATORY USE ONLY. READ MSDS PRIOR TO USE.

More information

[ a ppl ic at ion no t e ]

[ a ppl ic at ion no t e ] [ a ppl ic at ion no t e ] Fast A nalysis of A ldehydes and K etones by A C Q U I T Y U P L C Mark E. Benvenuti Waters Corporation, Milford, MA, USA INT RO DUC T ION Aldehydes and ketones are products

More information

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay... Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials (HPLC grade)... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation...

More information

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.) LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.) SOP-316 391 S. Vidal St., Sarnia, Ontario, N7T 7L1 Phone: (519) 344-4747 Fax: (519) 344-2350 E-Mail: info@lambtonscientific.com Method

More information

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0-0 TestAmerica Job ID: 00-0- TestAmerica Sample Delivery Group: 00-0 Client For: ARCADIS U.S. Inc

More information

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS 1.0 SCOPE AND APPLICATION 1.1 Method 5000 provides general guidance on the selection of sample preparation methods (purge-and-trap, extraction,

More information

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4 page1 of 8 TNI Standard VOLUME 1 MODULE 4 QUALITY SYSTEMS FOR CHEMICAL TESTING SECTIONS 1.5.1 AND 1.5.2 January 2016 Description This TNI Standard has been taken through all of the voting stages and has

More information

RIGHT SOLUTIONS RIGHT PARTNER

RIGHT SOLUTIONS RIGHT PARTNER 2655 Park Center Dr., Suite A Simi Valley, CA 93065 T: +1 805 526 7161 F: +1 805 526 7270 www.alsglobal.com LABORATORY REPORT March 14, 2016 Glenn La Fevers Southern California Gas Company 12801 Tampa

More information

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID) Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID) Table of Contents Section 1: Summary of Method Section 2: Scope and Application Section

More information

DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.

DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report. June 26, 2009 Charles E. Martin 11370 Breininger Road Hicksvile, OH 43526 TEL: (419) 542-6645 FAX: (419) 542-6475 Order No: 0906168 RE: Dear Charles E. Martin: DHL Analytical received 2 sample(s) on 6/18/2009

More information

Quantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector

Quantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector SOP # 04/30/6 04/30/6 of 4 Mike Klasner Mike Klasner 04/30/6 Quantitative determination of cannabinoids in Hemp and Hemp products by High Performance Liquid Chromatography using a UV Detector.0 PURPOSE.

More information

How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports

How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports Railroad Environmental Conference University of Illinois at Urbana-Champaign November 1 and 2, 2016 Erin E. Rodgers Environmental

More information

VOTING DRAFT STANDARD

VOTING DRAFT STANDARD page 1 of 7 VOTING DRAFT STANDARD VOLUME 1 MODULE 4 QUALITY SYSTEMS FOR CHEMICAL TESTING SECTIONS 1.5.1 AND 1.5.2 Description This Voting Draft Standard is a proposed revision of the 2009 standard (EL-

More information

Agilent MassHunter Workstation Software

Agilent MassHunter Workstation Software Agilent MassHunter Workstation Software Quantitative Analysis Quantitation DataSet Agilent Technologies Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced in any form or by

More information

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter ANALYTICAL REPORT TestAmerica Laboratories, Inc. 0 Community Drive Suite South Burlington, VT 00 Tel: (0)0- TestAmerica Job ID: 00-- TestAmerica Sample Delivery Group: 00- Client For: ARCADIS U.S. Inc

More information

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS 1.0 Purpose - This procedure specifies the required elements for the extraction and quantitation of THC,

More information

TO-15 Checklist Determination of VOCs in Air by GC-MS

TO-15 Checklist Determination of VOCs in Air by GC-MS LAB ID: DATE: LAB NAME: ASSESSOR NAME: Method Number: TO-15 Checklist Determination of VOCs in Air by GC-MS SOP Number: Revision Number: SOP Date: Personnel records observed: Data records observed: Revision

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Christopher Borton AB SCIEX Golden, Colorado verview Described here is the analysis of

More information

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE Use objectives: state purpose for which results will be used. Specifications: How good should the numbers be

More information

Uncontrolled Copy. SOP Ethylene Glycol Quantitation by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Uncontrolled Copy. SOP Ethylene Glycol Quantitation by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay... Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials (HPLC grade)... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation

More information

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington ANALYTICAL REPORT Job Number: 460-43877-1 Job Description: 17338-TO4-2012, RACER, GM Wilmington For: Conestoga-Rovers & Associates, Inc. 2055 Niagara Falls Blvd., Suite 3 Niagara Falls, NY 14304 Attention:

More information

Appendix II- Bioanalytical Method Development and Validation

Appendix II- Bioanalytical Method Development and Validation A2. Bioanalytical method development 1. Optimization of chromatographic conditions Method development and optimization of chromatographic parameters is of utmost important for validating a method in biological

More information

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Replaces: Dated: Author: Date: AM-No.: New New Nils Arne Jentoft 18.06.2014 0 CHANGES This procedure is new. 1 SCOPE This document describes

More information

METHOD 8000A GAS CHROMATOGRAPHY

METHOD 8000A GAS CHROMATOGRAPHY METHOD 8000A GAS CHROMATOGRAPHY 1.0 SCOPE AND APPLICATION 1.1 Gas chromatography is a quantitative technique useful for the analysis of organic compounds capable of being volatilized without being decomposed

More information

GC/MS Analysis Laboratory Report

GC/MS Analysis Laboratory Report Report No.: J-123456 Date: March 1, 2016 P.O. No.: PO 1234A GC/MS Analysis Laboratory Report Prepared for: Mr. Customer Name Company Name, Inc. 123 First St. Your City, State Prepared by: Bradley J. Cline

More information

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD APPENDIX V TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD Validating Chromatographic Methods. By David M. Bliesner Copyright 2006 John Wiley & Sons, Inc. 159 160 APPENDIX V Title: Effective: Document No:

More information

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method Rating Guide Appendix for the CCME Reference Method for the Canada-Wide Standard for Petroleum (PHC) in Soil - Tier 1 Method (Note: Checklist incorporates requirements from Dec 2000 version + Addendum

More information

Agilent MassHunter Quantitative Data Analysis

Agilent MassHunter Quantitative Data Analysis Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch Table, Compound Information Setup, Calibration Curve and Globals Settings 1 MassHunter

More information

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Quality Control Procedures for Graphite Furnace AAS using Avanta Software Application Note Quality Control Procedures for Graphite Furnace AAS using Avanta Software Introduction With the arrival of quality standards in the analytical laboratory, an ever increasing emphasis is

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 55 ONTENTS 1.0 OBJETIVE 2.0 APPLIABILITY 3.0 DESRIPTION 3.1 Sample ontainers, Preservative, Storage and Holding Times 3.1.1 Objective 3.1.2 Requirements 3.1.3 Evaluation Procedure 3.1.4 Action

More information

Laboratory 101: A Guide to Understanding your Testing Laboratory

Laboratory 101: A Guide to Understanding your Testing Laboratory Laboratory 101: A Guide to Understanding your Testing Laboratory Jim Cronin Product Ecology Manager Environmental Monitoring and Technologies, Inc. (EMT) Morton Grove, Illinois Abstract: Laboratory 101:

More information

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis Application Note AN772 Introduction This application note describes the extraction of cocaine and a full range

More information

ALLOWAY METHOD OUTLINE

ALLOWAY METHOD OUTLINE ALLOWAY METHOD OUTLINE Standard Laboratory Method SM4500-Cl -G Parameter Residual Chlorine & Free Chlorine Method DPD Colorimetric Test Kit Date Issued Originator: Section Supervisor: QA Manager Date:

More information

Uncontrolled Copy. Table of Contents. 1. Principle of Assay Specimens Reagents and Materials... 3

Uncontrolled Copy. Table of Contents. 1. Principle of Assay Specimens Reagents and Materials... 3 Table of Contents 1. Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation and Parameters...

More information

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water Hach Method 1041 Spectrophotometric Measurement of Free Chlorine (Cl ) in Finished Drinking Water Hach Company Method 1041 Revision 1. November 015 Spectrophotometric Measurement of Free Cl in Finished

More information

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Organics Revision Date: July 19, 2017 Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM Parameter Perfluorinated Alkyl Acids (Perfluorobutane Sulphonate (PFBS), Perflourooctane Sulphonate (PFOS),

More information

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis Hach Method 1061 Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis Hach Company Method 1061 Revision 1. December 015 Organic Carbon in Finished

More information

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES STANDARD OPERATING PROCEDURES for Spectrophotometric Measurement Chl a, Chl b, and Bulk Carotenoids using Methanol Solvent Prepared by EcoAnalysts, Inc. 1420 South Blaine Street, Suite 14 Moscow, ID 83843

More information

Impact factor: 3.958/ICV: 4.10 ISSN:

Impact factor: 3.958/ICV: 4.10 ISSN: Impact factor: 3.958/ICV: 4.10 ISSN: 0976-7908 99 Pharma Science Monitor 9(4), Oct-Dec 2018 PHARMA SCIENCE MONITOR AN INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES Journal home page: http://www.pharmasm.com

More information

Analytical Report

Analytical Report Analytical Report 386228 for Natural Soap Formulas Project Manager: Wanda Baligad Formula 206 Natural Soap Formulas 20-AUG-10 3231 NW 7th Avenue, Boca Raton, FL 33431 Ph:(561) 447-7373 Fax:(561) 447-6136

More information

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS 1.0 SCOPE AND APPLICATION 1.1 Method 8100 is used to determine the concentration of certain polynuclear aromatic hydrocarbons (PAH). Table 1 indicates compounds

More information

Measurement Uncertainty: A practical guide to understanding what your results really mean.

Measurement Uncertainty: A practical guide to understanding what your results really mean. Measurement Uncertainty: A practical guide to understanding what your results really mean. Overview General Factors Influencing Data Variability Measurement Uncertainty as an Indicator of Data Variability

More information

KSA Environmental Laboratory Inc.

KSA Environmental Laboratory Inc. September 07, 2007 KSA Environmental Laboratory Inc. Amerigrow Recycling Attn: Orlando D. Pagan 10320 West Atlantic Ave Delray Beach, FL 33446 RE: Mulch Metals KSA Workorder: Q006081 Dear Orlando D. Pagan,

More information

EPAs New MDL Procedure What it Means, Why it Works, and How to Comply

EPAs New MDL Procedure What it Means, Why it Works, and How to Comply EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows TestAmerica Inc. 1 A Revision to the Method Detection Limit EPA published a revision to the 40 CFR Part 136 MDL procedure

More information

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research Heather A Brown, 1 Claudia Rossi, 2 and Lisa J Calton 1 1 Waters Corporation, Wilmslow, UK 2

More information

ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011

ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011 ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011 1,2-DIBROMOETHANE (EDB) AND 1,2-DIBROMO-3-CHLOROPROPANE (DBCP) IN WATER BY MICROEXTRACTION AND GAS CHROMATOGRAPHY SOP #: 504.1 Revision 1.1,

More information

ALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)

ALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508) Eight Walkup Drive Westborough, Massachusetts 01581-1019 (508) 898-9220 www.alphalab.com MA:M-MA086 NH:200301-A CT:PH-0574 ME:MA086 RI:65 NY:11148 NJ:MA935 Army:USACE CERTIFICATE OF ANALYSIS Client: Fulham

More information

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP. NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION OFFICE OF QUALITY ASSURANCE ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM ON-SITE LABORATORY EVALUATION RADIOCHEMISTRY PROCEDURES Gross Alpha-Gross Beta

More information

Total Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector

Total Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector Title: TPH-SHC Page 1 of 18 Total Petroleum and Saturated Hydrocarbons by Gas Chromatography/Flame Ionization Detector References: USEPA, Method 8015D Nonhalogenated Organics Using GC/FID, in Test Methods

More information

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry NOTICE: This method has been developed by the EURL-CEFAO using the facilities available in its laboratories.

More information

~ ALG ANALYTICAL LABORATORY GROUP

~ ALG ANALYTICAL LABORATORY GROUP August 19, 2016 Doug Pigman Greater Albany Public Schools 3610 Grand Prairie Albany, OR 97322 TEL: (541) 967-4513 FAX RE: Waverly Retest Order No.: 1608769 Dear Doug Pigman: Analytical Laboratory Group

More information

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS #=CL# LIMS USE: FR - JILL LAVOIE LIMS OBJECT ID: July 16, 2015 Jill Lavoie Merrimack Village District - UCMR3 2 Greens Pond Road Merrimack, NH 03054 RE: Dear Jill Lavoie: Enclosed are the analytical results

More information

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC Technical Procedure for Concentration Determination of 1.0 Purpose This procedure specifies the required elements for the preparation and use of the Agilent 1100/1200 series High Performance Liquid Chromatograph

More information

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800) 2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 Analytical Report November 19, 2004 Report to: Debbie Furlow 602 Lehmberg Road Columbus, MS 39702 Bill to: Accounts Payable PO Box 2487 Columbus,

More information

APPENDIX D Laboratory Analytical Reports

APPENDIX D Laboratory Analytical Reports Allied Aviation Initial Abatement Report, Arlington, VA December 4, 2015 Amec Foster Wheeler Project 37650016 APPENDIX D Laboratory Analytical Reports #=CL# LIMS USE: FR - JOHN MITTAUER LIMS OBJECT ID:

More information

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method: ALLOWAY METHOD OUTLINE Standard Laboratory Method: SM Parameter: Methylene Blue Method: Colorimetric Reporting Level: Reference: 0.05 mg/l Standard Methods for the Examination Of Water and Wastewater;

More information

Method Validation and Accreditation

Method Validation and Accreditation SELAMAT Mycotoxins Workshop China, 11-15th December 2006 Method Validation and Accreditation Dr Hamide Z Şenyuva Senior Research Scientist TÜBİTAK-ATAL, TURKEY hamide.senyuva@tubitak.gov.tr SELAMAT Mycotoxins

More information

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997 Appendix A Glossary of Definitions, Acronyms, Abbreviations and Symbols March 1997 Glossary Of Definitions, Acronyms, Abbreviations And Symbols 1.0 Standard Acronyms, Abbreviations, And Symbols 1.1 Units

More information

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis Technical Procedure for Solid Phase Extraction of THC and THC-COOH 1.0 Purpose - This procedure specifies the required elements for the extraction of THC and THC-COOH using United Technologies Styre Screen

More information

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,

More information

December 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:

December 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections: December 30, 2018 ENVIRONMENTAL AGRICULTURAL Meadowlark Ranches Mutual Water Co. Lab ID : SP 1816365 Attn: Mike Hadley P.O. Box 606 Santa Ynez, CA 93460-0606 Customer : 2-21676 Laboratory Report This Page

More information

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC. 7. Stability indicating analytical method development and validation of and in capsule dosage form by HPLC. 7.1 INSTRUMENTS AND MATERIALS USED 7.1.1 INSTRUMENTS 1. Shimadzu LC-2010 CHT with liquid chromatograph

More information

Qualification Specifications for Agilent 1100/1200 HPLC Systems

Qualification Specifications for Agilent 1100/1200 HPLC Systems Agilent 1100/1200 HPLC Systems 35 Vantage Point Drive, Rochester NY 14624 Phone: 800-828-1470 Fax: 800-395-0543 Transcat.com Test Set Points/ Range Acceptance Criteria Flow Rate Accuracy and Precision

More information

Uncontrolled Copy. Table of Contents. 1. Introduction and Principle of Assay Specimens Reagents and Materials...

Uncontrolled Copy. Table of Contents. 1. Introduction and Principle of Assay Specimens Reagents and Materials... Table of Contents 1. Introduction and Principle of Assay... 3 2. Specimens... 3 3. Reagents and Materials... 3 4. Standards, Controls, and Solutions... 4 5. Equipment and Special Supplies... 5 6. Instrumentation

More information

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Figure 1. Structures for Vitamin B2 and Vitamin B1. CH 461 & CH 461H F 15 Name Experiment 2C Integrated Laboratory Experiment DETERMINATION OF RIBOFLAVIN: A COMPARISON OF TECHNIQUES PART C. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY The purpose of this experiment

More information

VOC TEST REPORT CDPH

VOC TEST REPORT CDPH Euro Trade Flooring SL. Pol. Ind. Can Estella c/galileo no. 11 08635 Sant Esteve Sesrovires BARCELONA SPAIN Eurofins Product Testing A/S Smedeskovvej 38 8464 Galten Denmark VOC@eurofins.com www.eurofins.com/voc-testing

More information

EPA TO-17 Volatile Organic Compounds

EPA TO-17 Volatile Organic Compounds EPA TO-17 Volatile Organic Compounds Method TO-17 is used to analyze samples for volatile organic compounds collected on multi-bed sorbent tubes, which are thermally desorbed and cryo-focused on the capillary

More information

Analysis of BTEX in Natural Water with SPME

Analysis of BTEX in Natural Water with SPME Analysis of BTEX in Natural Water with SPME Application Note Environmental Author Giordano Vassalli Sezione Protezione Aria Introduction Benzene, toluene, ethylbenzene and xylene (BTEX) isomers are monocyclic

More information