SUPPLEMENTARY INFORMATION
|
|
- Darrell Wiggins
- 6 years ago
- Views:
Transcription
1 Detection of gamma photons using solution-grown single crystals of hybrid lead halide perovskites Sergii Yakunin, 1, 2 Dmitry N. Dirin, 1, 2 Yevhen Shynkarenko 1,3, Viktoriia Morad, 1 Ihor Cherniukh, 1 Olga Nazarenko, 1,2 Dominik Kreil, 1 Thomas Nauser, 4 and Maksym V. Kovalenko *1,2 1 Laboratory of Inorganic Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland 2 Laboratory for Thin Films and Photovoltaics, Empa Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf, Switzerland 3 Department of Photonic Processes, Institute of Physics, National Academy of Sciences of Ukraine, 46 Prospekt Nauky, Kyiv 03680, Ukraine 4 Institute of Pharmaceutical Sciences, Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland * mvkovalenko@ethz.ch NATURE PHOTONICS 1
2 Supplementary Note 1. Calculation of the sensitivity of a MAPbI 3 SC to soft X-rays in a photoconductive mode of operation. The X-ray photon flux, F, onto the MAPbI 3 SC was measured to be cm -2 s -1. The ionizing radiation dose in a single crystal (SC) of MAPbI 3 was then calculated as: DD =!!!!!.!"!!!"!! 2.9!"#!"!! (S1), where ρ is the specific density of the SC of MAPbI 3, E ph is the X-ray photon energy (8 kev for Cu Kα soft X-rays) and l is the penetration depth, i.e., the depth up to which the quantity 1-e -1 (63%) of X-ray photons with an energy of 8 kev is absorbed. In air, the ionizing radiation dose would be ~6.9 times smaller than inside a SC of MAPbI 3 due to the lower X-ray photon absorption of air: DD!"# 0.42!"#!"#!"!! (S2). The sensitivity, G, of a SC of MAPbI 3 with an irradiated area, S, of 8 mm 2 with a photocurrent, ΔI, of 22 na is: GG =!" 0.65!! (S3),!!"#!!"!!!"#!"#!"! and the corresponding specific sensitivity, taking into account the absorption depth of 30 µm, is ~220 µc mgy air 1 cm NATURE PHOTONICS
3 SUPPLEMENTARY INFORMATION Supplementary Note 2. Evaluation of the efficiency of photons-to-carriers conversion in a photoconductive mode of operation. For the evaluation of the efficiency of photons-to-carriers conversion, we measured the activity, A, of a 11 C source to be 70 GBq. This permitted the estimation of the photon flux in a solid angle of the detector of area, S, of 12 mm 2 displaced at a distance, R, of 10 cm from the source. We took into account that the decay of 11 C produces two photons with the energy, E ph1, of MeV from electron-positron annihilation and one gamma photon with the energy, E ph2, of 0.98 MeV. We also include different penetration (absorption) depths for these photon energies in MAPbI 3 SC: l 1 =22 mm and l 2 =55 mm, respectively, for MeV and 0.98 MeV photons. From the value of the photocurrent (ΔI) of 5 na produced by a detector with a thickness, d, of 2 mm we evaluated the photon energy efficiency, η, as (where W is the charge pair creation energy): ηη =!!!!!!"!!!!!!!!!!!!!!!!!!!!!!!!!!! 19% (S4), This takes into account only one type of charge carrier, owing to the fact that the mobilities of holes in MAPbI 3 SCs are notably larger (4-6 times) than that of electrons (see Ref. 5 of the Main Text). The gamma photon to charge carrier generation efficiency (charge carriers per absorbed gamma photon) is estimated as: ηη!!!!!!!!!!!! ! (S5). NATURE PHOTONICS 3
4 Supplementary Figure 1. Measurement of the decay time after a gamma pulse shows the applicability of a computer soundcard as a multichannel analyser. The relaxation time of ~100 µs is suitable for acquisition by a PC sound card with a discretization frequency of 144 khz. 4 NATURE PHOTONICS
5 SUPPLEMENTARY INFORMATION Supplementary Figure 2. A two-pixel gamma detector constructed on a single iodine-treated MAPbBr 3 SC. Such a choice of a crystal stems from the convenient rectangular shape of MAPbBr 3 SCs, whereas I-treatment is needed for improving the sensitivity to gamma-photons. (a) Bipolar signal pulses from the signal electrode. (b) Counting profiles recorded simultaneously for each pixel as a function of source displacement ( 137 Cs source activity A=2.2 MBq, displacement speed 0.1 mm/s). The inset shows a schematic of the detector and the locations of the three electrodes (one signal and two bias electrodes). NATURE PHOTONICS 5
6 Supplementary Figure 3. Energy-resolved spectrum of 241 Am recorded with CdZnTe SC. 6 NATURE PHOTONICS
7 SUPPLEMENTARY INFORMATION Supplementary Figure 4. Energy resolved spectra of an 241 Am source recorded by an I-treated MAPbBr 3 SC cooled with dry ice to ~220 K. It should be noted that the increase of bias from 100 to 140 V shifts the photo-peak to higher MCA channels, illustrating that charge-collection efficiency remains a strongly limiting factor. Also the µτ product of I-treated MAPbBr 3 SCs is lower than that of MAPbI 3 SCs by a factor of 3. These observations clearly demonstrate that compositional engineering of lead halide perovskites for improving the spectral resolution should concentrate on minimizing the ionic drift, while maximizing the µτ product. NATURE PHOTONICS 7
Temperature dependent behavior of lead sulfide quantum dot solar cells and films.
Electronic Supplementary Material (ESI) for Energy & Environmental Science. This journal is The Royal Society of Chemistry 2016 Supplementary Information Temperature dependent behavior of lead sulfide
More informationEfficient Aluminium Chloride Natural Graphite Battery
Supporting Information for Efficient Aluminium Chloride Natural Graphite Battery Kostiantyn V. Kravchyk,,# Shutao Wang,,# Laura Piveteau, and Maksym V. Kovalenko *,, Laboratory of Inorganic Chemistry,
More informationEE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors
EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors 5. Radiation Microsensors Radiation µ-sensors convert incident radiant signals into standard electrical out put signals. Radiant Signals Classification
More informationSupplementary Information for. Red Phosphorus as High-Performance Anode Materials for Naion. Batteries
Supplementary Information for Inexpensive Antimony Nanocrystals and Their Composites with Red Phosphorus as High-Performance Anode Materials for Naion Batteries Marc Walter, 1, 2 Rolf Erni, 3 and Maksym
More informationDevelopment of Gamma-ray Monitor using CdZnTe Semiconductor Detector
Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector A. H. D. Rasolonjatovo 1, T. Shiomi 1, T. Nakamura 1 Y. Tsudaka 2, H. Fujiwara 2, H. Araki 2, K. Matsuo 2, H. Nishizawa 2 1 Cyclotron
More informationWeek 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices
Week 7: Ch. 0 Spec. w/ Scintillation Ctrs. multiplier Devices Spectroscopy with Scint. Counters -- gamma-ray interactions, reprise -- observed spectra --- spectral components, backscatter --- summing --
More informationRadiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons
Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na Ellen Simmons 1 Contents Introduction Review of the Types of Radiation Charged Particle Radiation Detection Review of Semiconductor
More informationSensitized solar cells with colloidal PbS-CdS core-shell quantum dots Lai, Lai-Hung; Protesescu, Loredana; Kovalenko, Maksym V.
University of Groningen Sensitized solar cells with colloidal PbS-CdS core-shell quantum dots Lai, Lai-Hung; Protesescu, Loredana; Kovalenko, Maksym V.; Loi, Maria Published in: Physical Chemistry Chemical
More informationPERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY
Applications of Nuclear Techniques (CRETE3) International Journal of Modern Physics: Conference Series Vol. 27 (24) 4644 (8 pages) The Authors DOI:.42/S294546446 PERFORMANCE IMPROVEMENT OF CZT DETECTORS
More informationGAMMA RAY SPECTROSCOPY
GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions
More informationRadiation Detection and Measurement
Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron
More informationApplication of positrons in materials research
Application of positrons in materials research Trapping of positrons at vacancy defects Using positrons, one can get defect information. R. Krause-Rehberg and H. S. Leipner, Positron annihilation in Semiconductors,
More informationEEE4106Z Radiation Interactions & Detection
EEE4106Z Radiation Interactions & Detection 2. Radiation Detection Dr. Steve Peterson 5.14 RW James Department of Physics University of Cape Town steve.peterson@uct.ac.za May 06, 2015 EEE4106Z :: Radiation
More informationGamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production
Experiment N2: Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production References: 1. Experiments in Nuclear
More informationDevelopment and characterization of 3D semiconductor X-rays detectors for medical imaging
Development and characterization of 3D semiconductor X-rays detectors for medical imaging Marie-Laure Avenel, Eric Gros d Aillon CEA-LETI, DETectors Laboratory marie-laure.avenel@cea.fr Outlines Problematic
More informationCd(Zn)Te semiconductor-based diodes for detection of X- and gamma-ray photons with high energy resolution and imaging formation
P-46 Cd(Zn)Te semiconductor-based diodes for detection of X- and gamma-ray photons with high energy resolution and imaging formation [1] Organization Project Leader: Volodymyr Gnatyuk, Ph.D., Assoc. Prof.,
More informationSUPPLEMENTARY INFORMATION
Supplementary Information Efficient inorganic-organic hybrid heterojunction solar cells containing perovskite compound and polymeric hole conductors Jin Hyuck Heo, Sang Hyuk Im, Jun Hong Noh, Tarak N.
More informationAssessing Temperature Dependence of Drift. Mobility in Methylammonium Lead Iodide
Supporting Information Assessing Temperature Dependence of Drift Mobility in Methylammonium Lead Iodide Perovskite Single Crystals Shreetu Shrestha, Gebhard J. Matt*, Andres Osvet, Daniel Niesner, Rainer
More informationInAs avalanche photodiodes as X-ray detectors
Home Search Collections Journals About Contact us My IOPscience InAs avalanche photodiodes as X-ray detectors This content has been downloaded from IOPscience. Please scroll down to see the full text.
More informationAdvanced lab course for Bachelor s students
Advanced lab course for Bachelor s students Versuch T2 Gamma spectroscopy and Compton scattering February 2018 Prerequisites Interactions of photons and matter Working principle and usage of scintillation
More informationScintillation Detector
Scintillation Detector Introduction The detection of ionizing radiation by the scintillation light produced in certain materials is one of the oldest techniques on record. In Geiger and Marsden s famous
More informationSemiconductor Detectors
Semiconductor Detectors Summary of Last Lecture Band structure in Solids: Conduction band Conduction band thermal conductivity: E g > 5 ev Valence band Insulator Charge carrier in conductor: e - Charge
More informationV. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber
CYRIC Annual Report 2001 V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber Kawata N. Baba M. Kato M.*, Miura T.**, and Yamadera A.***, Cyclotron and Radioisotope Center, Tohoku
More informationPHYS 3650L - Modern Physics Laboratory
PHYS 3650L - Modern Physics Laboratory Laboratory Advanced Sheet Photon Attenuation 1. Objectives. The objectives of this laboratory exercise are: a. To measure the mass attenuation coefficient at a gamma
More informationAnalysis of γ spectrum
IFM The Department of Physics, Chemistry and Biology LAB 26 Analysis of γ spectrum NAME PERSONAL NUMBER DATE APPROVED I. OBJECTIVES - To understand features of gamma spectrum and recall basic knowledge
More informationOpto-electronic Characterization of Perovskite Thin Films & Solar Cells
Opto-electronic Characterization of Perovskite Thin Films & Solar Cells Arman Mahboubi Soufiani Supervisors: Prof. Martin Green Prof. Gavin Conibeer Dr. Anita Ho-Baillie Dr. Murad Tayebjee 22 nd June 2017
More informationGamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production
Experiment N2: Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production References: 1. Experiments in Nuclear
More informationIntensity / a.u. 2 theta / deg. MAPbI 3. 1:1 MaPbI 3-x. Cl x 3:1. Supplementary figures
Intensity / a.u. Supplementary figures 110 MAPbI 3 1:1 MaPbI 3-x Cl x 3:1 220 330 0 10 15 20 25 30 35 40 45 2 theta / deg Supplementary Fig. 1 X-ray Diffraction (XRD) patterns of MAPbI3 and MAPbI 3-x Cl
More informationComparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data
International Journal of Advanced Research in Physical Science (IJARPS) Volume 5, Issue 10, 2018, PP 24-28 ISSN No. (Online) 2349-7882 www.arcjournals.org Comparison of the Photo-peak Efficiencies between
More informationGamma ray coincidence and angular correlation
University of Cape Town Department of Physics Course III laboratory Gamma ray coincidence and angular correlation Introduction Medical imaging based on positron emission tomography (PET) continues to have
More informationSUPPLEMENTARY INFORMATION
SUPPLEMENTARY INFORMATION Supplementary Information for Mid-infrared HgTe colloidal quantum dot photodetectors Sean Keuleyan, Emmanuel Lhuillier, Vuk Brajuskovic and Philippe Guyot-Sionnest* Optical absorption
More informationQuantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16530 Quantitative Assessment of Scattering
More informationSUPPLEMENTARY INFORMATION
In the format provided by the authors and unedited. DOI: 1.138/NMAT4927 Dopant Compensation in Alloyed CH 3 NH 3 PbBr 3-x Cl x Perovskite Single Crystals for Gamma-ray Spectroscopy Haotong Wei 1, Dylan
More informationReviewers' comments: Reviewer #1 (Remarks to the Author):
Reviewers' comments: Reviewer #1 (Remarks to the Author): This manuscript reports on direct X-ray photoconversion in flexible, ultra-low voltage organic thin film devices. The manuscript contains some
More informationSupplementary Figure 1. A photographic image of directionally grown perovskite films on a glass substrate (size: cm).
Supplementary Figure 1. A photographic image of directionally grown perovskite films on a glass substrate (size: 1.5 4.5 cm). 1 Supplementary Figure 2. Optical microscope images of MAPbI 3 films formed
More informationSupplementary Figure 1 Transient absorption (TA) spectrum pumped at 400 nm in the FAPbI3 sample with different excitation intensities and initial
Supplementary Figure 1 Transient absorption (TA) spectrum pumped at 400 nm in the FAPbI3 sample with different excitation intensities and initial carrier concentrations: (a) N0 = 4.84 10 18 cm -3 ; (c)
More informationSupporting Information for. Long-Distance Charge Carrier Funneling in Perovskite Nanowires Enable by Built-in Halide Gradient
Supporting Information for Long-Distance Charge Carrier Funneling in Perovskite Nanowires Enable by Built-in Halide Gradient Wenming Tian, Jing Leng, Chunyi Zhao and Shengye Jin* State Key Laboratory of
More informationDetermination of the activity of radionuclides
BUREAU NATIONAL DE MÉTROLOGIE COMMISSARIAT À L'ÉNERGIE ATOMIQUE LABORATOIRE NATIONAL HENRI BECQUEREL Note technique LNHB/04-33 Determination of the activity of radionuclides contained in volume samples
More informationLAB 4: Gamma-ray coincidence spectrometry (2018)
LAB 4: Gamma-ray coincidence spectrometry (2018) As you have seen, in several of the radioactive sources we encountered so far, they typically emit more than one gamma photon per decay or even more than
More informationTHE spectroscopic performance of large volume CdZnTe
3098 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 6, DECEMBER 2004 Analysis of Detector Response Using 3-D Position-Sensitive CZT Gamma-Ray Spectrometers Feng Zhang, Student Member, IEEE, Zhong He,
More informationGeneral Overview of Gas Filled Detectors
GAS-FILLED DETECTOR General Overview of Gas Filled Detectors Gas-Filled Detectors Ion chamber Proportional counter G-M (Geiger-Miller) counter Diagram of a Generic Gas-Filled Detector A Anode High-voltage
More informationDetermination of the shielding power of different materials against gamma radiation
Determination of the shielding power of different materials against gamma radiation Chow Wing Yan, Yeung Chun Lap S.K.H Tsang Shiu Tim Secondary School Wong Ka Wing Baptist Lui Ming Choi Secondary School
More informationStability and Characteristics of Large CZT Coplanar Electrode Detectors
272 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 48, NO. 3, JUNE 2001 Stability and Characteristics of Large CZT Coplanar Electrode Detectors José M. Pérez, Zhong He, Senior Member, IEEE, and David K. Wehe,
More informationTrace alpha-particle detection system for water networks: from direct detection in liquid phase to element identification
Trace alpha-particle detection system for water networks: from direct detection in liquid phase to element identification J. De Sanoit, M. Pomorski, P. Bergonzo 1 We want CONTXT In emergency situations
More informationWM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA
The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool 13461 Victor Potapov, Alexey Safronov, Oleg Ivanov, Sergey Smirnov, Vyacheslav Stepanov National Research
More informationDetermination of Ambient Dose Equivalent at INFLPR 7 MeV Linear Accelerator
Determination of Ambient Dose quivalent at INFLPR 7 MeV Linear Accelerator F. Scarlat, A. Scarisoreanu, M. Oane,. Badita,. Mitru National Institute for Laser, Plasma and Radiation Physics - INFLPR, Bucharest-Magurele,
More informationScience of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University
Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University Notes to accompany Lab demonstrations by Barry Diacon, Technician, Department of
More informationInternational Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN
316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science
More informationSupporting Information. Single-Layer Halide Perovskite Light-Emitting. Diodes with Sub-Bandgap Turn-on Voltage and
Supporting Information Single-Layer Halide Perovskite Light-Emitting Diodes with Sub-Bandgap Turn-on Voltage and High Brightness Junqiang Li, Xin Shan, Sri Ganesh R. Bade, Thomas Geske,, Qinglong Jiang,
More informationChapter 4 Scintillation Detectors
Med Phys 4RA3, 4RB3/6R03 Radioisotopes and Radiation Methodology 4-1 4.1. Basic principle of the scintillator Chapter 4 Scintillation Detectors Scintillator Light sensor Ionizing radiation Light (visible,
More informationHigh-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy
High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy Thomas Niedermayr, I. D. Hau, S. Terracol, T. Miyazaki, S. E. Labov and S. Friedrich Former colleagues: M. F. Cunningham, J. N.
More informationApplied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra
22.101 Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra References: W. E. Meyerhof, Elements of Nuclear Physics (McGraw-Hill, New York, 1967),
More informationRESPONSE CALCULATIONS OF THE CdZnTe DETECTOR USING EGS4. James C. Liu, W. R. Nelson and R. Seefred
SLAC-PUB-8606 (September 5, 2000) RESPONSE CALCULATIONS OF THE CdZnTe DETECTOR USING EGS4 James C. Liu, W. R. Nelson and R. Seefred Stanford Linear Accelerator Center, MS 48, P. O. Box 4349, Stanford,
More informationChapiter VII: Ionization chamber
Chapiter VII: Ionization chamber 1 Types of ionization chambers Sensitive volume: gas (most often air direct measurement of exposure) ionization chamber Sensitive volume: semiconductor (silicon, germanium,
More informationDependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution
Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution Chikkappa Udagani Abstract: This paper presents the precise method to estimate the dependence of linear and mass
More informationEnergetic particles and their detection in situ (particle detectors) Part II. George Gloeckler
Energetic particles and their detection in situ (particle detectors) Part II George Gloeckler University of Michigan, Ann Arbor, MI University of Maryland, College Park, MD Simple particle detectors Gas-filled
More informationFebruary 1, 2011 The University of Toledo, Department of Physics and Astronomy SSARE, PVIC
FUNDAMENTAL PROPERTIES OF SOLAR CELLS February 1, 2011 The University of Toledo, Department of Physics and Astronomy SSARE, PVIC Principles and Varieties of Solar Energy (PHYS 4400) and Fundamentals of
More informationBoron-based semiconductor solids as thermal neutron detectors
Boron-based semiconductor solids as thermal neutron detectors Douglas S. McGregor 1 and Stan M. Vernon 2 1 S.M.A.R.T. Laboratory, Department of Nuclear Engineering and Radiological Sciences, University
More information[1] Laboratory for Thin Films and Photovoltaics, Empa - Swiss Federal Laboratories for
Supporting Information The Effect of Gallium Substitution on Lithium Ion Conductivity and Phase Evolution in Sputtered Li 7-3x Ga x La 3 Zr 2 O 12 Thin Films: Supporting Information M. Rawlence 1,2, A.
More informationSemiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH
Semiconductor X-Ray Detectors Tobias Eggert Ketek GmbH Semiconductor X-Ray Detectors Part A Principles of Semiconductor Detectors 1. Basic Principles 2. Typical Applications 3. Planar Technology 4. Read-out
More informationFast Polycrystalline-CdTe Detector for LHC Luminosity Measurements
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN SL DIVISION CERN SL-2002-001 BI Fast Polycrystalline-CdTe Detector for LHC Luminosity Measurements E. Rossa, E. Gschwendtner, M. Placidi, H. Schmickler,
More informationSupplementary Figure 1 XRD pattern of a defective TiO 2 thin film deposited on an FTO/glass substrate, along with an XRD pattern of bare FTO/glass
Supplementary Figure 1 XRD pattern of a defective TiO 2 thin film deposited on an FTO/glass substrate, along with an XRD pattern of bare FTO/glass and a reference pattern of anatase TiO 2 (JSPDS No.: 21-1272).
More informationElectronic Supplementary Information. Thermal Annealing Reduces Geminate Recombination in TQ1:N2200 All- Polymer Solar Cells
Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2018 Thermal Annealing Reduces Geminate Recombination in TQ1:N2200 All- Polymer
More informationMEASUREMENT AND DETECTION OF RADIATION
MEASUREMENT AND DETECTION OF RADIATION Second Edition Nicholas Tsoulfanidis University of Missouri-Rolla Ж Taylor &Francis * Publishers since I79H CONTENTS Preface to the First Edition Preface to the Second
More informationINTERACTIONS OF RADIATION WITH MATTER
INTERACTIONS OF RADIATION WITH MATTER Renée Dickinson, MS, DABR Medical Physicist University of Washington Medical Center Department of Radiology Diagnostic Physics Section Outline Describe the various
More informationInternational Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN
308 Angular dependence of 662 kev multiple backscattered gamma photons in Aluminium Ravindraswami K a, Kiran K U b, Eshwarappa K M b and Somashekarappa H M c* a St Aloysius College (Autonomous), Mangalore
More informationIntroduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48
Introduction to Environmental Measurement Techniques 2016 Radioactivity Dana Pittauer (dpittauer@marum.de) 1of 48 Introduction Radioisotopes are of interest in environmental physics for several reasons:
More informationGamma Spectroscopy. References: Objectives:
Gamma Spectroscopy References: G.F. Knoll, Radiation Detection and Measurement (John Wiley & Sons, New York, 2000) W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-to Approach,
More informationSpatial resolved efficiency determination of CdZnTe semiconductor detectors with a collimated gamma-ray source for the C0BRA experiment
Institute of Nuclear and Particle Physics, Prof. K. Zuber Spatial resolved efficiency determination of CdZnTe semiconductor detectors with a collimated gamma-ray source for the C0BRA experiment Arnd Sörensen
More informationAdvantages / Disadvantages of semiconductor detectors
Advantages / Disadvantages of semiconductor detectors Semiconductor detectors have a high density (compared to gas detector) large energy loss in a short distance diffusion effect is smaller than in gas
More information(002)(110) (004)(220) (222) (112) (211) (202) (200) * * 2θ (degree)
Supplementary Figures. (002)(110) Tetragonal I4/mcm Intensity (a.u) (004)(220) 10 (112) (211) (202) 20 Supplementary Figure 1. X-ray diffraction (XRD) pattern of the sample. The XRD characterization indicates
More informationThe Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)
The Compton Effect Martha Buckley MIT Department of Physics, Cambridge, MA 02139 marthab@mit.edu (Dated: November 26, 2002) We measured the angular dependence of the energies of 661.6 kev photons scattered
More informationOutline. Introduction, motivation Readout electronics, Peltier cooling Input J-FETsJ
Progress in low energy X-rayX spectroscopy using semi-insulating insulating GaAs detectors F. Dubecký 1, B. Zaťko 1, P. Boháček 1, L. Ryć 2, E. Gombia 2, and V. Nečas 3 1 IEE SAS, Bratislava, Slovakia
More informationSpatially Non-Uniform Trap State Densities in Solution-Processed Hybrid Perovskite Thin Films
Spatially Non-Uniform Trap State Densities in Solution-Processed Hybrid Perovskite Thin Films Sergiu Draguta 1, Siddharatka Thakur 1,2, Yurii Morozov 1, Yuanxing Wang 1, Joseph S. Manser 3,4, Prashant
More informationAbsolute activity measurement
Absolute activity measurement Gábor Veres, Sándor Lökös Eötvös University, Department of Atomic Physics January 12, 2016 Financed from the financial support ELTE won from the Higher Education Restructuring
More informationCopyright 2008, University of Chicago, Department of Physics. Gamma Cross-sections. NaI crystal (~2" dia) mounted on photo-multiplier tube
Gamma Cross-sections 1. Goal We wish to measure absorption cross-sections for γ-rays for a range of gamma energies and absorber atomic number. 2. Equipment Pulse height analyzer Oscilloscope NaI crystal
More informationDetecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)
Detecting high energy photons Interactions of photons with matter Properties of detectors (with examples) Interactions of high energy photons with matter Cross section/attenution length/optical depth Photoelectric
More informationA Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 3, JUNE 2002 1547 A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate Wanno Lee, Gyuseong Cho, and Ho
More informationIII. Energy Deposition in the Detector and Spectrum Formation
1 III. Energy Deposition in the Detector and Spectrum Formation a) charged particles Bethe-Bloch formula de 4πq 4 z2 e 2m v = NZ ( ) dx m v ln ln 1 0 2 β β I 0 2 2 2 z, v: atomic number and velocity of
More informationThe Ones That Got Away: Neutron Leakage Spectra
The Ones That Got Away: Neutron Leakage Spectra Some neutrons are able to exit the surface before being captured The energies of these neutrons depend on their scattering history Fast neutrons that scatter
More informationSlides by: Prof. Abeer Alharbi
Slides by: Prof. Abeer Alharbi electromagnetic radiation of high energy. They are produced by sub-atomic particle interactions, such as electron-positron annihilation, neutral pion decay, radioactive decay,
More informationand Technology, Luoyu Road 1037, Wuhan, , P. R. China. *Corresponding author. ciac - Shanghai P. R.
Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry Supplementary Information For Journal of Materials Chemistry A Perovskite- @BiVO
More informationSUPPLEMENTARY INFORMATION
Supporting Online Material for Lead-Free Solid State Organic-Inorganic Halide Perovskite Solar Cells Feng Hao, 1 Constantinos C. Stoumpos, 1 Hanh Cao, 1 Robert P. H. Chang, 2 Mercouri G. Kanatzidis 1*
More informationPlasmonic Hot Hole Generation by Interband Transition in Gold-Polyaniline
Supplementary Information Plasmonic Hot Hole Generation by Interband Transition in Gold-Polyaniline Tapan Barman, Amreen A. Hussain, Bikash Sharma, Arup R. Pal* Plasma Nanotech Lab, Physical Sciences Division,
More informationSample Spectroscopy System Hardware
Semiconductor Detectors vs. Scintillator+PMT Detectors Semiconductors are emerging technology - Scint.PMT systems relatively unchanged in 50 years. NaI(Tl) excellent for single-photon, new scintillation
More informationGamma and X-Ray Detection
Gamma and X-Ray Detection DETECTOR OVERVIEW The kinds of detectors commonly used can be categorized as: a. Gas-filled Detectors b. Scintillation Detectors c. Semiconductor Detectors The choice of a particular
More informationList of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide
Nuclear Medicine Imaging Systems: The Scintillation Camera List of Nuclear Medicine Radionuclides Tc99m 140.5 kev 6.03 hours I-131 364, 637 kev 8.06 days I-123 159 kev 13.0 hours I-125 35 kev 60.2 days
More informationDetection and measurement of gamma-radiation by gammaspectroscopy
Detection and measurement of gamma-radiation by gammaspectroscopy Gamma-radiation is electromagnetic radiation having speed equal to the light in vacuum. As reaching a matter it interact with the different
More informationOptical and THz investigations of mid-ir materials exposed
Optical and THz investigations of mid-ir materials exposed to alpha particle irradiation Dan Sporea 1*, Laura Mihai 1, Adelina Sporea 1, Ion Vâţã 2 1 National Institute for Laser, Plasma and Radiation
More informationInexpensive Colloidal SnSb Nanoalloys as Efficient Anode Materials for Lithium- and Sodium-Ion Batteries
Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A. This journal is The Royal Society of Chemistry 2016 Supplementary Information for Inexpensive Colloidal SnSb Nanoalloys as
More informationNew perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors
New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors Jean-Marc Dinten, Jean-Louis Amans, Loïck Verger, Olivier Peyret CEA-LETI, MINATEC, Recherche
More informationLecture 12. Semiconductor Detectors - Photodetectors
Lecture 12 Semiconductor Detectors - Photodetectors Principle of the pn junction photodiode Absorption coefficient and photodiode materials Properties of semiconductor detectors The pin photodiodes Avalanche
More informationOPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626
OPTI510R: Photonics Khanh Kieu College of Optical Sciences, University of Arizona kkieu@optics.arizona.edu Meinel building R.626 Announcements Homework #6 is assigned, due May 1 st Final exam May 8, 10:30-12:30pm
More informationNew trends in CdTe detectors for X and γ-ray applications
New trends in CdTe detectors for X and γ-ray applications Olivier Limousin CEA Saclay / DSM / DAPNIA Service d Astrophysique France New developments in photodetection, Beaune 2002 / Solid state detectors
More informationEnglish CPH E-Book Theory of CPH Section 2 Experimental Foundation of CPH Theory Hossein Javadi
English CPH E-Book Theory of CPH Section 2 Experimental Foundation of CPH Theory Hossein Javadi Javadi_hossein@hotmail.com Contains: Introduction Gravitational Red Shift Gravity and the Photon Mossbauer
More informationChemical Engineering 412
Chemical Engineering 412 Introductory Nuclear Engineering Lecture 26 Radiation Detection & Measurement II Spiritual Thought 2 I would not hold the position in the Church I hold today had I not followed
More informationRadiation Dose, Biology & Risk
ENGG 167 MEDICAL IMAGING Lecture 2: Sept. 27 Radiation Dosimetry & Risk References: The Essential Physics of Medical Imaging, Bushberg et al, 2 nd ed. Radiation Detection and Measurement, Knoll, 2 nd Ed.
More informationSupporting Information
Supporting Information Controlled Crystal Grain Growth in Mixed Cation-Halide Perovskite by Evaporated Solvent Vapor Recycling Method for High Efficiency Solar Cells Youhei Numata,*, Atsushi Kogo, Yosuke
More informationLeft: ToF-SIMS 3D Oxygen ion plot of a MAPI film. Right: ToF-SIMS 3D Oxygen ion plot of a MAPIC film.
C fresh fresh C aged Intensity (a. u.) Intensity 2 2 3 3 4 4 6 2 Theta / deg 2 2 3 3 4 4 6 2 Theta / deg Supplementary Figure 1. XRD Patterns Left: XRD patterns of CH 3 NH 3 PbI 3 and CH 3 NH 3 PbI 3 (Cl)
More informationSupplementary material for High responsivity mid-infrared graphene detectors with antenna-enhanced photo-carrier generation and collection
Supplementary material for High responsivity mid-infrared graphene detectors with antenna-enhanced photo-carrier generation and collection Yu Yao 1, Raji Shankar 1, Patrick Rauter 1, Yi Song 2, Jing Kong
More information