BaF 2 :Ce POLYMER COMPOSITE GAMMA-RAY SCINTILLATORS M.B. Barta, J.H. Nadler, Z. Kang, B.K. Wagner

Size: px
Start display at page:

Download "BaF 2 :Ce POLYMER COMPOSITE GAMMA-RAY SCINTILLATORS M.B. Barta, J.H. Nadler, Z. Kang, B.K. Wagner"

Transcription

1 BaF 2 :Ce POLYMER COMPOSITE GAMMA-RAY SCINTILLATORS M.B. Barta, J.H. Nadler, Z. Kang, B.K. Wagner Georgia Tech Research Institute 925 Dalney St, Atlanta, GA Keywords Barium halide, nanophosphor, nanocomposite, gamma-ray scintillator Abstract A nanocomposite gamma-ray scintillator contains nanoscale phosphor particles (nanophosphors) encapsulated in a polymer matrix. These scintillators show great promise for improving the cost and durability of scintillators for gamma-ray detector systems because single crystal scintillators currently in use have high cost and hygroscopicity, and are available in limited compositions and sizes. This research utilizes two different commercially available epoxies to encapsulate two different nanophosphors (BaF 2 :2%Ce and BaF 2 :15%Ce). The importance of three parameters are illustrated: photon efficiency of the encapsulated nanophosphor, refractive index (RI) match between the nanophosphor and polymer matrix, and the %transmission of the polymer at the wavelength at which the BaF 2 :Ce nanophosphors emit gamma-ray excited photons. Introduction Current gamma-ray scintillators are primarily large single crystals of Thallium doped NaI. While single crystal scintillators are currently the most efficient available, their drawbacks include hygroscopicity, a limited choice of composition, and a low-yield growth process that frequently introduces defects [1]. Nanoscale phosphor powders (nanophosphors) encapsulated in a polymer matrix may provide improved scintillation performance. Due to their potential for environmental insensitivity, mechanical durability, and flexibility both in size and geometry, nanophosphors encapsulated in a polymer matrix could provide improved performance for a range of applications [2]. Figure 1: Schematic of gamma-ray detector system

2 The gamma-ray detector discussed is a materials system comprised of polymer composite scintillator loaded with phosphor particles, and a photomultiplier tube (PMT) detector (see Figure 1). Upon interaction with gamma radiation, these phosphor particles encapsulated in the polymer matrix emit photons via energy transitions of excited electrons. The emitted photons are then channeled through the polymer matrix to the PMT and classified into a range of energies, thus generating a characteristic energy spectrum dependent on the radioactive isotope of the source [3]. The three main scintillator properties of interest to this investigation are matched refractive index (RI) between the nanophosphor and the epoxy matrix, the %transmission exhibited by the nanophosphor loaded epoxies, and the photon efficiency of the nanophosphors. These properties are crucial for ensuring that gamma-ray excited photons generated by the scintillator material propagate through the matrix and deposit their full energy onto the PMT, thus generating a high resolution energy spectrum. The importance of RI matching and high %transmission will be shown via quantitative data collected on nanophosphor loaded epoxy samples and qualitative determination of the RI of the nanophosphors and epoxies. The potential benefits provided by nanophosphors in gamma-ray detection include greater photon yields and shorter decay times by minimizing photon absorption and scattering due to impurities (a problem in large crystal growth) [4-5]. However, encapsulated nanophosphors can exhibit light scattering due to refractive index (RI) mismatch at the particle-matrix interfaces. Encapsulating the nanophosphors into an appropriate polymer matrix can provide an improved RI match, permitting more photons to propagate to the PMT, minimizing scattering, and thus signal loss [2]. In particular, BaF 2 :Ce nanophosphors (average size of approximately 40nm [8]) provide the highest luminescent efficiency of nanophosphors previously studied [8], and fluoresce in the near-uv range ( nm) as shown in Figure 2. Lower energy alpha-radiation will not excite electrons in BaF 2 particles, which allows the nanophosphor to generate scintillation photons solely from high energy gamma-ray excitation. This energy discrimination significantly reduces signal noise from the resulting energy spectrum [6]. The nanophosphors used in this study were synthesized using an adaptation of a chemical precipitation synthesis for LaF 3 :Ce [7,8]. Figure 2 shows photoluminescence (PL) data for the 2-30mol% doping levels synthesized, and indicates that BaF 2 :15%Ce produces the highest photon efficiency. In this work, BaF 2 :15%Ce and BaF 2 :2%Ce are encapsulated in polymer matrices to confirm the effects of two luminescent efficiency levels. High solids loadings (40mg per ml of epoxy or higher) of the organic matrix are required to compensate for the reduced volume of scintillating material as compared to bulk single crystal scintillators [2], and so two different solids loading levels of the BaF 2 :Ce nanophosphors are encapsulated in two types of epoxy matrices with different RI and transmission levels at nm.

3 Figure 2: PL data for BaF 2 :Ce using 288nm excitation wavelength [8] Photons generated by the nanophosphors must be able to propagate to the photomultiplier tube (PMT) and deposit their full energy in order to generate useful data. Sufficient matching of the RI between the nanophosphor and its matrix will promote light propagation rather than scattering within the scintillator [9]. However, due to dispersion, the RI that allows 589nm light to propagate uninhibited is different from the RI that allows 389nm or 400nm light to propagate. Thus, matching the RI of the nanophosphor and the matrix at the wavelength at which a nanophosphor will generate gamma-ray excited photons is desired. Gamma-ray measurements provide information regarding the scintillator photon yield (or efficiency) when exposed to a gamma radiation source, such as 241 Am. A good scintillator must be able to transform the full energy of the gamma-ray into emitted photons (excitons) that can be deposited onto the PMT and generate an energy spectrum [10]. Procedure Refractive Index Matching The RI of BaF 2 :Ce was measured by combining the 2mg of nanophosphor with 0.5mL of liquid with known RI at 589nm from Cargille Labs Inc. (Cedar Grove, NJ) on a standard glass microscope slide. These slides were placed on a clean silicon wafer and viewed with a Leica M165C optical microscope under 400nm LED illumination (see Figure 3). The extent of visual detection of the powder agglomerates submerged in each RI liquid was used as the criteria to estimate the RI of the particles. After a matching liquid was found, a manufacturer provided dispersion curve for the specific liquid was used to create a polynomial fit to the data and approximate the RI of the particles at 389nm (see Figure 4).

4 Figure 3: Refractive index matching apparatus Figure 4: Extrapolated RI curve for BaF 2 :Ce nanophosphors based on RI matching Nanocomposite Synthesis For this investigation, two different commercially available epoxies are used to encapsulate the BaF 2 :Ce nanophosphors: Epo-TEK 301-2FL and Epo-TEK 305 (from Epoxy Technology, Inc., Billerica, MA). Both polymers are two part epoxy mixtures and both have room or high temperature cure capabilities. The most notable difference is in their RI values: Epo-TEK 305 has a RI of while Epo-TEK 301-2FL has a RI of (both at 589nm). The difference in RI will affect the way generated photons will travel through the matrix, and thus affect the overall performance of the scintillator. BaF 2 :15%Ce and BaF 2 :2%Ce nanoparticles with loading levels of 40mg nanophosphor per ml epoxy and 100mg/mL were added gradually to 5mL samples of Epo-TEK 301-2FL and Epo- TEK 305. The phosphor loaded polymers were then poured into 32mm diameter cylindrical

5 molds to form disks approximately 3mm thick. The molds were placed in an ultrasonic bath to enhance particle dispersion for 20 minutes, placed under vacuum (<1torr) for 5 minutes to remove any entrapped air and any remaining agglomerations, and allowed to cure at room temperature. Following curing, the samples were polished prior to transmission or gamma-ray measurements to minimize surface scattering. Gamma-ray Measurements Gamma-ray measurements were conducted using a radionuclide source placed on top of the thin phosphor loaded polymer samples. Optical grease was applied between the radionuclide and the scintillator to prevent interface scattering. The sample and source were placed on a photomultiplier tube (PMT) and the entire assembly was shielded to block external light. Photons generated by the scintillator were recorded by the PMT, and their energy and intensity in a range of 1-12keV distributed over 1,040 channels with a total counting time of 5,000 seconds. Transmission Measurements Transmission measurements in the range of nm were conducted using a Cary 5000 UV- Vis-NIR Spectrophotometer (Varian, Inc., Walnut Creek, CA) to observe the sample behavior near the wavelength at which BaF 2 :Ce generates gamma-ray excited photons [8]. Unloaded samples of both polymers were scanned in addition to all of the nanophosphor-loaded samples. Results & Discussion Phosphor Nanopowder Encapsulation Following encapsulation of both of the BaF 2 :15%Ce and BaF 2 :2%Ce powders, the Epo-TEK 301-2FL appeared to produce the most transparent phosphor-loaded disk prior to curing. As expected, the 100mg/ml loadings in both epoxies after curing exhibited greater opacity than the 40mg/mL loadings. This difference was an expected effect of increased nanophosphor particle loading. Gamma-ray Measurements Figure 5(a) and (b) are plots of gamma-ray detector data ( 241 Am source) for BaF 2 :15%Ce encapsulated in the Epo-TEK 305 and Epo-TEK 301-2FL, respectively. Epo-TEK 301-2FL based components generated much lower photon intensities compared to Epo-TEK 305, a likely result of its higher index of refraction (1.512 at 589nm) relative to the Epo-TEK 305 and the nanophosphors. This large index mismatch would cause greater scattering of any photons traveling through the scintillator. The 100mg/mL phosphor loading in Epo-TEK 305 exhibited greater photon efficiency than the 40mg/mL loading due to a higher phosphor loading density, which would allow for greater material interaction with incident gamma-rays, and thus greater photon production. The absence of a discernable trend in solids loading in the BaF 2 :15%Ce loaded Epo-TEK 301-2FL samples is probably due to the low transmission of that epoxy in the nm range. Figure 6(a) and (b) are plots of gamma-ray detector data for the epoxies loaded with BaF 2 :2%Ce nanophosphors under a 241 Am source. The performance of the different solids loadings vary less in the BaF 2 :2%Ce measurements, but the efficiency of the BaF 2 :15%Ce nanophosphors is nearly five times greater that of the BaF 2 :2%Ce phosphors, indicating the necessity for a highly efficient nanophosphor as the scintillation material.

6 (a) (b) Figure 5: Photon intensities generated by BaF 2 :15%Ce loaded in (A) Epo-TEK 305 samples and (B) Epo- TEK 301-2FL samples, both excited by a 241 Am radionuclide source (a) (b) Figure 6: Photon intensities generated by BaF 2 :2%Ce loaded in (A) Epo-TEK 305 samples and (B) Epo- TEK 301-2FL, both excited by a 241 Am source Despite the superior detection performance of the 100mg/mL loading of BaF2:15%Ce in Epo- TEK 305 epoxy, the light intensity measured by the PMT remains far below that of single crystals. The best single crystal scintillator currently in use, NaI(Tl) generates photons with intensities nearly an order of magnitude higher than the nanophosphor composite scintillators, as shown in Figure 7. One way to mitigate this difference may be to increase the solids loading of the nanophosphor in the polymer matrix, providing a quantity of luminescent sites comparable to that of single crystals, which are composed entirely of scintillating material. Figure 7: Photon intensity generated by a NaI(Tl) single crystal

7 Transmission Measurements Figure 8(a) shows a transmission spectrum from nm for the polymer disks loaded with varying amounts of BaF 2 :15%Ce nanophosphors, while Figure 8(b) is a transmission spectrum for epoxies loaded with BaF 2 :2%Ce nanophosphors. The Epo-TEK 305 epoxy loaded with 100mg/mL BaF 2 :15%Ce exhibited the greatest transmission over the spectrum. This was unexpected to some degree as a disk containing a higher solids loading of nanophosphor would have a greater area of interfaces due to mismatched RI, and thus measured greater light scattering (as indicated by the lower %transmission of 100mg/mL BaF 2 :15%Ce in Epo-TEK 301-2FL). The discrepancy may be due to variations in particle agglomeration between samples or surface defects on the disk. However, it was expected that the Epo-TEK 305 epoxy would show improved transmission over Epo-TEK 301-2FL epoxy because according to the manufacturer provided data, Epo-TEK 301-2FL is not transparent to prolonged UV exposure. The results in Figure 8(b) indicate much lower transmission values for the epoxies loaded with BaF 2 :2%Ce nanophosphors. This is likely due to a combination of the much lower light yield of BaF 2 :2%Ce compared to BaF 2 :15%Ce and scattering from the epoxy matrix. These results suggest that it necessary to consider the photon efficiency of the phosphor in addition to RI matching and transmission efficiency of the matrix. Figure 9 shows a plot of the transmission from nm of the unloaded epoxies, and indicates that the addition of nanophosphor to the epoxy results in a nearly 50% decrease in the transmission values. These results suggest that matching the RI of the polymer matrix with the nanophosphors should improve transmission, and that an ideal polymer would have a RI of at 389nm. (a) (b) Figure 8: %Transmission measurements of (A) BaF 2 :15%Ce and (B) BaF 2 :2%Ce loaded epoxies. (I) 301-2FL, 100mg/mL, (II) 301-2FL, 40mg/mL, (III) 305, 100mg/mL, and (IV) 305, 40mg/mL Figure 9: %Transmission measurements of unloaded epoxies

8 Conclusions & Future Work Nanophosphor composite scintillators promise to improve the durability and lower the cost of gamma-ray scintillators by improving photon yields and decreasing environmental sensitivity. Light scattering and low photon yield must be further investigated in order to elevate the practicality of nanophosphors to the level of single crystals. Future experiments will investigate the potential of Eu 2+ dopants to increase the photon yield. Photon scattering can also be reduced if a polymer or other material with a RI matching that of the nanophosphor (1.485 at 589nm) is procured. Acknowledgements The author gratefully acknowledges Dr. Jason H. Nadler and Dr. Zhitao Kang of the Georgia Tech Research Institute at the Georgia Institute of Technology for their supervision and guidance. Research was conducted as part of an initiative by the Domestic Nuclear Detection Office (DNDO) in response to the SAFE Port Act. References 1. C.W.E. van Eijk. Inorganic-scintillator Development, Nuclear Instruments & Methods in Physics Research, (A 460) (2001), E.A. McKigney et al., Nanocomposite scintillators for radiation detection and nuclear spectroscopy, Nuclear Instruments and Methods in Physcis Research, A (579) (2007), Brent K. Wagner, private communication with author, Georgia Tech Research Institute, 15 June W.H. Tait. Radiation Detection; Butterworth: Boston, D.W. Cook, Luminescent properties and reduced dimensional behavior of hydrothermally prepared Y 2 SiO 5 :Ce nanophosphors, Applied Physics Letters, 2006, vol. 88, A.V. Golovin. Mechanism of short-wavelength luminescence of barium fluoride, Optics and Spectroscopy, 1988, vol. 65, J. del-castillo. Wide colour gamut generated in triply lanthanide doped sol-gel nano-glassceramics, Journal of Nanoparticle Research, 2009, M.B. Barta, Gamma Ray Scintillators via BaF 2 :Ce Nanopowders (Paper presented at the 96 th MS&T Annual Meeting, Pittsburgh, PA, 26 October 2009) 9. R.S. Meltzer et al., Effect of the matrix on the radiative lifetimes of rare earth doped nanoparticles embedded in matrices, Journal of Luminescence, (94-95) (2001), B.D. Milbrath et al., Radiation detector materials: an overview, Journal of Materials Research, (23) (2008),

SCINTILLATION DETECTORS AND PM TUBES

SCINTILLATION DETECTORS AND PM TUBES SCINTILLATION DETECTORS AND PM TUBES General Characteristics Introduction Luminescence Light emission without heat generation Scintillation Luminescence by radiation Scintillation detector Radiation detector

More information

Radioactivity. Lecture 6 Detectors and Instrumentation

Radioactivity. Lecture 6 Detectors and Instrumentation Radioactivity Lecture 6 Detectors and Instrumentation The human organs Neither humans nor animals have an organ for detecting radiation from radioactive decay! We can not hear it, smell it, feel it or

More information

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION OBJECTIVE The primary objective of this experiment is to use an NaI(Tl) detector, photomultiplier tube and multichannel analyzer software system

More information

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous? 2. Briefly discuss dead time in a detector. What factors are important

More information

05 - Scintillation detectors

05 - Scintillation detectors 05 - Scintillation detectors Jaroslav Adam Czech Technical University in Prague Version 2 Jaroslav Adam (CTU, Prague) DPD_05, Scintillation detectors Version 2 1 / 39 Scintillation detector principles

More information

Radionuclide Imaging MII Detection of Nuclear Emission

Radionuclide Imaging MII Detection of Nuclear Emission Radionuclide Imaging MII 3073 Detection of Nuclear Emission Nuclear radiation detectors Detectors that are commonly used in nuclear medicine: 1. Gas-filled detectors 2. Scintillation detectors 3. Semiconductor

More information

Chapter 4 Scintillation Detectors

Chapter 4 Scintillation Detectors Med Phys 4RA3, 4RB3/6R03 Radioisotopes and Radiation Methodology 4-1 4.1. Basic principle of the scintillator Chapter 4 Scintillation Detectors Scintillator Light sensor Ionizing radiation Light (visible,

More information

Radiation Dose, Biology & Risk

Radiation Dose, Biology & Risk ENGG 167 MEDICAL IMAGING Lecture 2: Sept. 27 Radiation Dosimetry & Risk References: The Essential Physics of Medical Imaging, Bushberg et al, 2 nd ed. Radiation Detection and Measurement, Knoll, 2 nd Ed.

More information

Platinum resistance. also wirewound versions. eg

Platinum resistance. also wirewound versions. eg Platinum resistance Platinum resistance Very stable and reproducible, wide T range (~ -200 C to 1000 C) T coefficient ~ +0.4%/ C Bulky and expensive for some applications (~ 2-3) need wires (R) or local

More information

Supporting Information

Supporting Information Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2015 Supporting Information All inorganic cesium lead halide perovskite nanocrystals for photodetector

More information

Photonic structuring improves colour purity of rare-earth. nanophosphors

Photonic structuring improves colour purity of rare-earth. nanophosphors Electronic Supplementary Material (ESI) for Materials Horizons. This journal is The Royal Society of Chemistry 2018 Supporting Information Photonic structuring improves colour purity of rare-earth nanophosphors

More information

Gamma Spectroscopy. References: Objectives:

Gamma Spectroscopy. References: Objectives: Gamma Spectroscopy References: G.F. Knoll, Radiation Detection and Measurement (John Wiley & Sons, New York, 2000) W. R. Leo, Techniques for Nuclear and Particle Physics Experiments: A How-to Approach,

More information

Scintillation Detectors

Scintillation Detectors Scintillation Detectors J.L. Tain Jose.Luis.Tain@ific.uv.es http://ific.uv.es/gamma/ Instituto de Física Corpuscular C.S.I.C - Univ. Valencia Scintillation detector: SCINTILLATION MATERIAL LIGHT-GUIDE

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement June 2008 Tom Lewellen Tkldog@u.washington.edu Types of radiation relevant to Nuclear Medicine Particle Symbol Mass (MeV/c 2 ) Charge Electron e-,! - 0.511-1 Positron

More information

Scintillation Detectors

Scintillation Detectors Radiation Measurement Systems Scintillation Detectors Ho Kyung Kim Pusan National University Scintillation detector = scintillator + light sensor Scintillators Inorganic alkali halide crystals Best light

More information

The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+

The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+ JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS Vol. 13, No. 2, February 2011, p. 111-116 The Scintillation properties of Pr 3+ doped and Pr 3+, Ce 3+ doubly doped LaBr 3 X. GAO *, Y. J. HE, Y. B. CHEN

More information

Time-Resolved Liquid Scintillation Counting

Time-Resolved Liquid Scintillation Counting CHAPTER 44 Time-Resolved Liquid Scintillation Counting Norbert Roessler, Robert J. Valenta, and Stat van Cauter ABSTRACT A comparison is made between standard, two-tube coincidence liquid scintillation

More information

Inorganic Scintillators

Inorganic Scintillators Inorganic Scintillators Inorganic scintillators are inorganic materials (usually crystals) that emit light in response to ionizing radiation NaI is the protypical example Scintillation mechanism is different

More information

Survey of the performance of scintillation materials at low temperatures

Survey of the performance of scintillation materials at low temperatures Survey of the performance of scintillation materials at low temperatures Biswas Sharma University of Tennessee, Knoxville 4/5/2017 Particle Physics and Astro-Cosmology Seminar 1 Motivation Versatility

More information

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory Title Labr3:Ce scintillators for gamma ray spectroscopy Permalink https://escholarship.org/uc/item/38f0c7zv Authors Shah, K.S.

More information

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics Nuclear Physics Laboratory Gamma spectroscopy with scintillation detectors M. Makek Faculty of Science Department of Physics Zagreb, 2015 1 1 Introduction The goal of this excercise is to familiarize with

More information

Chapter Seven (Nuclear Detectors)

Chapter Seven (Nuclear Detectors) Al-Mustansiriyah University College of Science Physics Department Fourth Grade Nuclear Physics Dr. Ali A. Ridha Chapter Seven (Nuclear Detectors) Ionizing radiation is rarely detected directly. Instead,

More information

Supporting Information

Supporting Information Supporting Information Dynamic Interaction between Methylammonium Lead Iodide and TiO 2 Nanocrystals Leads to Enhanced Photocatalytic H 2 Evolution from HI Splitting Xiaomei Wang,, Hong Wang,, Hefeng Zhang,,

More information

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments Athena Ierokomos University of California, Berkeley 2013 University of California, Los Angeles REU Program Abstract Neutrinoless

More information

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON W. Hennig 1, H. Tan 1, W.K. Warburton 1, and J.I. McIntyre 2 XIA LLC 1, Pacific Northwest

More information

DETECTORS. I. Charged Particle Detectors

DETECTORS. I. Charged Particle Detectors DETECTORS I. Charged Particle Detectors A. Scintillators B. Gas Detectors 1. Ionization Chambers 2. Proportional Counters 3. Avalanche detectors 4. Geiger-Muller counters 5. Spark detectors C. Solid State

More information

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear Contents 1 Scintillation and Inorganic Scintillators... 1 1.1 The Phenomenon of Scintillation... 1 1.1.1 What Is a Scintillator?... 1 1.2 Survey of Scintillation Mechanisms.... 7 1.3 Scintillation Radiating

More information

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy Experiment VI Gamma Ray Spectroscopy 1. GAMMA RAY INTERACTIONS WITH MATTER In order for gammas to be detected, they must lose energy in the detector. Since gammas are electromagnetic radiation, we must

More information

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Unit 2. Instrumentation. Experts Teaching from Practical Experience Unit 2 Instrumentation Experts Teaching from Practical Experience Gas-Filled Detectors Gas-filled detectors measure the charge released when radiation interacts with the gas Three types: Ion Chambers,

More information

OPPORTUNITY TO JOIN IEEE AND NPSS

OPPORTUNITY TO JOIN IEEE AND NPSS OPPORTUNITY TO JOIN IEEE AND NPSS If you are NOT an IEEE Member, IEEE & NPSS offers you a FREE: Half-year membership in IEEE (value= ~$80)* Half-year membership in NPSS (value= ~$13)* Half-year subscription

More information

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber CYRIC Annual Report 2001 V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber Kawata N. Baba M. Kato M.*, Miura T.**, and Yamadera A.***, Cyclotron and Radioisotope Center, Tohoku

More information

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN 316 Effective atomic number of composite materials by Compton scattering - nondestructive evaluation method Kiran K U a, Ravindraswami K b, Eshwarappa K M a and Somashekarappa H M c* a Government Science

More information

Chemical Engineering 412

Chemical Engineering 412 Chemical Engineering 412 Introductory Nuclear Engineering Lecture 26 Radiation Detection & Measurement II Spiritual Thought 2 I would not hold the position in the Church I hold today had I not followed

More information

Interaction mechanism for energy transfer from Ce to Tb ions in silica

Interaction mechanism for energy transfer from Ce to Tb ions in silica Interaction mechanism for energy transfer from Ce to Tb ions in silica HAA Seed Ahmed 1,2, W-S Chae 3, OM Ntwaeaborwa 1 and RE Kroon 1 1 Department of Physics, University of the Free State, South Africa

More information

Exploiting the Interaction of Pyranine-3 with Poly(L-Lysine) to Mediate Nanoparticle Assembly: Fabrication of Dynamic ph-responsive Nanocontainers

Exploiting the Interaction of Pyranine-3 with Poly(L-Lysine) to Mediate Nanoparticle Assembly: Fabrication of Dynamic ph-responsive Nanocontainers Exploiting the Interaction of Pyranine-3 with Poly(L-Lysine) to Mediate Nanoparticle Assembly: Fabrication of Dynamic ph-responsive Nanocontainers Arlin Jose Amali, a Shashi Singh, b Nandini Rangaraj,

More information

Linear attenuation coefficient calculation for both pure silicon (Si) and silicone supported with lead

Linear attenuation coefficient calculation for both pure silicon (Si) and silicone supported with lead Linear attenuation coefficient calculation for both pure silicon (Si) and silicone supported with lead Mohammed AL fakhar 1, Harith Ibrahim 2, Athraa Mohan 3 1,2,3 Iraq- Wasit-University of Wasit College

More information

Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use

Investigation of Ce-doped Gd2Si2O7 as a scintillator. Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Instructions for use Title Investigation of Ce-doped Gd2Si2O7 as a scintillator Kawamura, Sohan; Kaneko, Junichi H.; Higuchi, Mikio; Author(s) Kurashige, Kazuhisa; Ishibashi, Hiroyuki; Furusaka, Nuclear Instruments and Methods

More information

GAMMA RAY SPECTROSCOPY

GAMMA RAY SPECTROSCOPY GAMMA RAY SPECTROSCOPY Gamma Ray Spectroscopy 1 In this experiment you will use a sodium iodide (NaI) detector along with a multichannel analyzer (MCA) to measure gamma ray energies from energy level transitions

More information

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors Radiation Detectors 1 How do we detect ionizing radiation? Indirectly, by its effects as it traverses matter? What are these effects? Ionization and excitation of the atoms and molecules Heat 2 Types of

More information

Researchers at the University of Missouri-Columbia have designed a triple crystal

Researchers at the University of Missouri-Columbia have designed a triple crystal Childress, N. L. and W. H. Miller, MCNP Analysis and Optimization of a Triple Crystal Phoswich Detector, Nuclear Instruments and Methods, Section A, 490(1-2), 263-270 (Sept 1, 2002). Abstract Researchers

More information

Quantum Dot Technology for Low-Cost Space Power Generation for Smallsats

Quantum Dot Technology for Low-Cost Space Power Generation for Smallsats SSC06-VI- Quantum Dot Technology for Low-Cost Space Power Generation for Smallsats Theodore G. DR Technologies, Inc. 7740 Kenamar Court, San Diego, CA 92020 (858)677-230 tstern@drtechnologies.com The provision

More information

Detectors for the measurement of ionizing radiation

Detectors for the measurement of ionizing radiation For the measurement of radiation, the following reactions during the irradiation of matter are predominantly utilized: Ionization in gases (Ionization chamber, proportional flow counter, release counter)

More information

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST 2008 2425 Optical and Scintillation Properties of Inorganic Scintillators in High Energy Physics Rihua Mao, Member, IEEE, Liyuan Zhang, Member,

More information

arxiv: v1 [physics.ins-det] 3 Feb 2011

arxiv: v1 [physics.ins-det] 3 Feb 2011 Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 Alogo.pdf Nuclear Instruments and Methods in Physics Research A Scintillation decay time and pulse shape discrimination in oxygenated

More information

Chapter 15 Molecular Luminescence Spectrometry

Chapter 15 Molecular Luminescence Spectrometry Chapter 15 Molecular Luminescence Spectrometry Two types of Luminescence methods are: 1) Photoluminescence, Light is directed onto a sample, where it is absorbed and imparts excess energy into the material

More information

Scintillation Detector

Scintillation Detector Scintillation Detector Introduction The detection of ionizing radiation by the scintillation light produced in certain materials is one of the oldest techniques on record. In Geiger and Marsden s famous

More information

GUIDE TO LABORATORY SURVEYS. Introduction

GUIDE TO LABORATORY SURVEYS. Introduction APPENDIX - V GUIDE TO LABORATORY SURVEYS Introduction Routine laboratory surveys are an important part of the overall radiation safety program in a laboratory. Surveys provide a direct measure of the presence

More information

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING W. Hennig 1, H. Tan 1, A. Fallu-Labruyere 1, W. K. Warburton 1, J. I. McIntyre 2, A. Gleyzer 3 XIA, LLC 1, Pacific Northwest National Laboratory

More information

Gamma and X-Ray Detection

Gamma and X-Ray Detection Gamma and X-Ray Detection DETECTOR OVERVIEW The kinds of detectors commonly used can be categorized as: a. Gas-filled Detectors b. Scintillation Detectors c. Semiconductor Detectors The choice of a particular

More information

Design and production of Scintillation Detectors

Design and production of Scintillation Detectors Design and production of Scintillation Detectors Components for nuclear radiation detectors Fields of application: * Medicine * Industry * Science * Security Scintillation Detectors : Instruments using

More information

LAAPD Performance Measurements in Liquid Xenon

LAAPD Performance Measurements in Liquid Xenon LAAPD Performance Measurements in Liquid Xenon David Day Summer REU 2004 Nevis Laboratories, Columbia University Irvington, NY August 3, 2004 Abstract Performance measurements of a 16mm diameter large

More information

The Mössbauer Effect

The Mössbauer Effect Experimental Physics V85.0112/G85.2075 The Mössbauer Effect Spring, 2005 Tycho Sleator, David Windt, and Burton Budick Goals The main goal of this experiment is to exploit the Mössbauer effect to measure

More information

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator 88 The 1 st NPRU Academic Conference SCI-O11 Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator P. Limkitjaroenporn and W.Chewpraditkul Radiation Physics Laboratory,

More information

Sample Spectroscopy System Hardware

Sample Spectroscopy System Hardware Semiconductor Detectors vs. Scintillator+PMT Detectors Semiconductors are emerging technology - Scint.PMT systems relatively unchanged in 50 years. NaI(Tl) excellent for single-photon, new scintillation

More information

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples Aim of this tal Detector technology WMIC Educational Program Nuclear Imaging World Molecular Imaging Congress, Dublin, Ireland, Sep 5-8, 202 You can now the name of a bird in all the languages of the world,

More information

Scintillators General Characteristics

Scintillators General Characteristics Scintillators General Characteristics Principle: de/dx converted into visible light Detection via photosensor [e.g. photomultiplier, human eye ] Main Features: Sensitivity to energy Fast time response

More information

Detection and measurement of gamma-radiation by gammaspectroscopy

Detection and measurement of gamma-radiation by gammaspectroscopy Detection and measurement of gamma-radiation by gammaspectroscopy Gamma-radiation is electromagnetic radiation having speed equal to the light in vacuum. As reaching a matter it interact with the different

More information

Scintillation detectors

Scintillation detectors 25 de dx Scintillation detectors excitation L25.pdf P627 YK 3/14/2012 detectable photons also by UV, or molecular collisions, chem. reactions, bubbles. etc. Detector building requirements (sometimes controversial):

More information

Boron Nitride, A Neutron Scintillator With Deficiencies

Boron Nitride, A Neutron Scintillator With Deficiencies Boron Nitride, A Neutron Scintillator With Deficiencies R. Engels, Member, IEEE, G. Kemmerling and J. Schelten Abstract During an electron beam evaporation accidentally sintered boron nitride was discovered

More information

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 19 Chapter 12 There are three major techniques used for elemental analysis: Optical spectrometry Mass spectrometry X-ray spectrometry X-ray Techniques include:

More information

Study of absorption and re-emission processes in a ternary liquid scintillation system *

Study of absorption and re-emission processes in a ternary liquid scintillation system * CPC(HEP & NP), 2010, 34(11): 1724 1728 Chinese Physics C Vol. 34, No. 11, Nov., 2010 Study of absorption and re-emission processes in a ternary liquid scintillation system * XIAO Hua-Lin( ) 1;1) LI Xiao-Bo(

More information

Supporting Information s for

Supporting Information s for Supporting Information s for # Self-assembling of DNA-templated Au Nanoparticles into Nanowires and their enhanced SERS and Catalytic Applications Subrata Kundu* and M. Jayachandran Electrochemical Materials

More information

"Neutron Flux Distribution"

Neutron Flux Distribution TECHNICAL UNIVERSITY DRESDEN Institute of Power Engineering Training Reactor Reactor Training Course Experiment "Neutron Flux Distribution" Instruction for Experiment Neutron Flux Distribution Content:

More information

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT: NUCLEAR MEDICINE Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Introduction to Medical Imaging: Physics, Engineering and Clinical Applications, by Nadine Barrie Smith

More information

quantum dots, metallic nanoparticles, and lanthanide ions doped upconversion

quantum dots, metallic nanoparticles, and lanthanide ions doped upconversion Chapter 1 Introduction 1.1 Background Nanostructured materials have significantly different characteristics from their bulk counterparts. 1 Inorganic nanoparticles such as semiconductor quantum dots, metallic

More information

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce F.C.L. Crespi 1,2, F.Camera 1,2, N. Blasi 2, A.Bracco 1,2, S. Brambilla 2, B. Million 2, R. Nicolini 1,2, L.Pellegri 1, S. Riboldi

More information

Week 6: Ch. 8 Scintillation Counters

Week 6: Ch. 8 Scintillation Counters Week 6: Ch. 8 cintillation Counters Proportional Counters Principles of cintillation Counters -- organic materials --- light production -- inorganic materials --- light production -- light output, collection

More information

Review of Optical Properties of Materials

Review of Optical Properties of Materials Review of Optical Properties of Materials Review of optics Absorption in semiconductors: qualitative discussion Derivation of Optical Absorption Coefficient in Direct Semiconductors Photons When dealing

More information

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search Hanwool Joo on behalf of the KIMS-NaI collaboration Department of Physics and Astronomy, 1 Gwanak-ro, Gwanak-gu, Seoul

More information

Scintillators 1. YEAR, I. CYCLE. AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob

Scintillators 1. YEAR, I. CYCLE. AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob Scintillators SEMINAR 1. YEAR, I. CYCLE AUTHOR: BPhys. Manja Ščetinec ADVISOR/MENTOR: Prof. Boštjan Golob Faculty of Mathematics and Physics, University in Ljubljana Ljubljana, October 2017 Abstract In

More information

Chem 481 Lecture Material 3/20/09

Chem 481 Lecture Material 3/20/09 Chem 481 Lecture Material 3/20/09 Radiation Detection and Measurement Semiconductor Detectors The electrons in a sample of silicon are each bound to specific silicon atoms (occupy the valence band). If

More information

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler Energetic particles and their detection in situ (particle detectors) Part II George Gloeckler University of Michigan, Ann Arbor, MI University of Maryland, College Park, MD Simple particle detectors Gas-filled

More information

Fundamentals of Radionuclide Metrology

Fundamentals of Radionuclide Metrology Fundamentals of Radionuclide Metrology Brian E. Zimmerman, PhD Physical Measurement Laboratory National Institute of Standards and Technology Gaithersburg, MD USA SIM Metrology Workshop Buenos Aires, Argentina

More information

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner J.E. Eberhardt, A.J. McEwan, D. Milinkovic, V. Sharp, * and J.R. Tickner CSIRO Minerals, Private Mail Bag 5, Menai NSW 2234 Australia

More information

THE COMPTON EFFECT Last Revised: January 5, 2007

THE COMPTON EFFECT Last Revised: January 5, 2007 B2-1 THE COMPTON EFFECT Last Revised: January 5, 2007 QUESTION TO BE INVESTIGATED: How does the energy of a scattered photon change after an interaction with an electron? INTRODUCTION: When a photon is

More information

Spectroscopic Study of FTO/CdSe (MPA)/ZnO Artificial Atoms Emitting White Color

Spectroscopic Study of FTO/CdSe (MPA)/ZnO Artificial Atoms Emitting White Color Spectroscopic Study of FTO/CdSe (MPA)/ZnO Artificial Atoms Emitting White Color Batal MA *, and Alyamani K Department of Physics, College of Science, Aleppo, Syria * Corresponding author: Batal MA, Department

More information

arxiv: v2 [physics.ins-det] 8 Feb 2013

arxiv: v2 [physics.ins-det] 8 Feb 2013 Preprint typeset in JINST style - HYPER VERSION arxiv:1302.0278v2 [physics.ins-det] 8 Feb 2013 Investigation of gamma ray detection performance of thin LFS scintillator with MAPD readout E.Guliyev a, F.Ahmadov

More information

arxiv: v1 [physics.ins-det] 29 Jun 2011

arxiv: v1 [physics.ins-det] 29 Jun 2011 Investigation of Large LGB Detectors for Antineutrino Detection P. Nelson a,, N. S. Bowden b, a Department of Physics, Naval Postgraduate School, Monterey, CA 99, USA b Lawrence Livermore National Laboratory,

More information

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa Synthesis of plastic scintillator Ildefonso León Monzón Universidad Autónoma de Sinaloa MUON BUNDLE triggered by plastic scintillator modules from ACORDE Plastic Scintillator how does it work? Excitation

More information

CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM

CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM U.S. -KOREA Forums on Nanotechnology 1 CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM February 17 th 2005 Eung-Sug Lee,Jun-Ho Jeong Korea Institute of Machinery & Materials U.S. -KOREA Forums

More information

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007 XENON Dark Matter Search Juliette Alimena Columbia University REU August 2 nd 2007 Evidence of Dark Matter Missing mass in Coma galaxy cluster (Fritz Zwicky) Flat rotation curves of spiral galaxies (Vera

More information

Characterization of the Lanthanum Chloride Scintillation Detector

Characterization of the Lanthanum Chloride Scintillation Detector Characterization of the Lanthanum Chloride Scintillation Detector François Kazadi Kabuya 1*, Zslot Podolyak 2 1 Commissariat Général à l Energie Atomique, PO BOX 868 Kinshasa XI, DR Congo 2 Department

More information

Supplementary Figure 1: (a) Upconversion emission spectra of the NaYF 4 4 core shell shell nanoparticles as a function of Tm

Supplementary Figure 1: (a) Upconversion emission spectra of the NaYF 4 4 core shell shell nanoparticles as a function of Tm Supplementary Figure 1: (a) Upconversion emission spectra of the NaYF 4 @NaYbF 4 :Tm(x%) @NaYF 4 core shell shell nanoparticles as a function of Tm 3+ content in the inner shell layer. The spectra were

More information

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring 1 Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering

More information

Radioactivity III: Measurement of Half Life.

Radioactivity III: Measurement of Half Life. PHY 192 Half Life Spring 2010 1 Radioactivity III: Measurement of Half Life. Introduction This experiment will once again use the apparatus of the first experiment, this time to measure radiation intensity

More information

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER 14-25 JUNE 2004 SUMMER STAGE PARTICLES REVELATION THROUGH SCINTILLATION COUNTER by Flavio Cavalli and Marcello De Vitis Liceo Scientifico Statale Farnesina Tutor: Marco Mirazita 1) COSMIC RAYS - The Muons

More information

NORM and TENORM: Occurrence, Characterizing, Handling and Disposal

NORM and TENORM: Occurrence, Characterizing, Handling and Disposal NORM and TENORM: Occurrence, Characterizing, Handling and Disposal Ionizing Radiation and Hazard Potential John R. Frazier, Ph.D. Certified Health Physicist May 12, 2014 Radiation Radiation is a word that

More information

Introduction to scintillators

Introduction to scintillators Introduction to scintillators M. Kobayashi (KEK) 17 November, 2003 1. Luminescence, fluorescence, scintillation, phosphorescence, etc. 2. Scintillation mechanism 3. Scintillation efficiency 4. Main characteristics

More information

CapeSym, Inc. Radiation Detection Solutions

CapeSym, Inc. Radiation Detection Solutions ScintiClear Plug & Play Developer Kit ScintiClear Developer Kit Our developer kit is a plug-and-play high energy resolution gamma spectrometer ready to measure in less than 30 minutes after the box is

More information

Radionuclide Imaging MII Positron Emission Tomography (PET)

Radionuclide Imaging MII Positron Emission Tomography (PET) Radionuclide Imaging MII 3073 Positron Emission Tomography (PET) Positron (β + ) emission Positron is an electron with positive charge. Positron-emitting radionuclides are most commonly produced in cyclotron

More information

Figure 1. Decay Scheme for 60Co

Figure 1. Decay Scheme for 60Co Department of Physics The University of Hong Kong PHYS3851 Atomic and Nuclear Physics PHYS3851- Laboratory Manual A. AIMS 1. To learn the coincidence technique to study the gamma decay of 60 Co by using

More information

Secondary Ion Mass Spectrometry (SIMS)

Secondary Ion Mass Spectrometry (SIMS) CHEM53200: Lecture 10 Secondary Ion Mass Spectrometry (SIMS) Major reference: Surface Analysis Edited by J. C. Vickerman (1997). 1 Primary particles may be: Secondary particles can be e s, neutral species

More information

Study of Isospin simmetry using the PARIS detector. Alice Mentana

Study of Isospin simmetry using the PARIS detector. Alice Mentana Study of Isospin simmetry using the PARIS detector Alice Mentana The Isospin simmetry Isospin Mixing (breaking of Isospin simmetry) Experimental technique: γ-decay of GDR Experimental apparatus: the PARIS

More information

Supporting Information. A new reductive DL-mandelic acid loading approach for moisture-stable Mn 4+ doped fluorides

Supporting Information. A new reductive DL-mandelic acid loading approach for moisture-stable Mn 4+ doped fluorides Electronic Supplementary Material (ESI) for Chemical Communications. This journal is The Royal Society of Chemistry 2018 Supporting Information A new reductive DL-mandelic acid loading approach for moisture-stable

More information

PHYSICS nd TERM Outline Notes (continued)

PHYSICS nd TERM Outline Notes (continued) PHYSICS 2800 2 nd TERM Outline Notes (continued) Section 6. Optical Properties (see also textbook, chapter 15) This section will be concerned with how electromagnetic radiation (visible light, in particular)

More information

Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method

Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method Fabrication of Radiation Sources for Educational Purposes from Chemical Fertilizers using Compressing and Forming Method Takao Kawano National Institute for Fusion Science 322-6 Oroshi, Toki, Gifu 509-5292,Japan

More information

maximal photofluorescence decay time of 6 hours (purchased from Shenzhen HuiDuoSheng

maximal photofluorescence decay time of 6 hours (purchased from Shenzhen HuiDuoSheng Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2017 Experimental section Preparation of m-tio 2 /LPP photoanodes. TiO 2 colloid was synthesized according

More information

Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ *

Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ * Characterization of the new scintillator Cs 2 LiYCl 6 :Ce 3+ * Li Kui-Nian ( 李奎念 ) 1;1) Zhang Xian-Peng ( 张显鹏 ) 1, 3) Gui Qiang ( 桂强 ) 2) Jin Peng ( 金鹏 ) 1 ) Tian Geng ( 田耕 ) 1) 1 Northwest Institute of

More information

Supporting Information for:

Supporting Information for: Supporting Information for: High Efficiency Low-Power Upconverting Soft Materials Jae-Hyuk Kim, Fan Deng, Felix N. Castellano,*, and Jae-Hong Kim*, School of Civil and Environmental Engineering, Georgia

More information

Compton suppression spectrometry

Compton suppression spectrometry Compton suppression spectrometry In gamma ray spectrometry performed with High-purity Germanium detectors (HpGe), the detection of low intensity gamma ray lines is complicated by the presence of Compton

More information