Spectrophotometry. Uranine Determination. 10-point-calibration for creating an own measurement method with photolab 7600 UV-VIS.

Size: px
Start display at page:

Download "Spectrophotometry. Uranine Determination. 10-point-calibration for creating an own measurement method with photolab 7600 UV-VIS."

Transcription

1 Spectrophotometry Uranine Determination 10-point-calibration for creating an own measurement method with photolab 7600 UV-VIS Uranine Uranine is the sodium salt of the fluoresceine. The pure material is a red-brown crystalline powder. In contrast to fluoresceine uranine has a good water solubility and dissolves in a yellow-green fluorescent dye. Uranine is used as dye for various materials, as a tracer to locate leakages in pipe system or for the investigation of flow paths and flow velocity in natural waterways. Figure 1: Usage of Uranine as a tracer at the entrance of a karst cave.(kit University of Baden-Württemberg and national research center of the Helmholtz-Society). User defined methods Programming an own measurement method gives the user a possibility to create or adapt an individual photometric measurement routine, using this method alike commercial available test kits in measurement and calculation of the result. In other words, setting up a calibration curve WTW GmbH. [Monat 201X]

2 Preparations For photometric measurements a calibration function describes the dependency between the absorbance as the basic indicator and a calculated concentration as the result. The knowledge of this dependency is a requirement for the development of a new method. Usually the calibration function will be determined by a series of measurements of known standard concentrations, for example with a so called 10-point-calibration. The software of the spectrophotomerters photolab 6000 and 7000 series supports user-defined method data programming. Spectrum Selecting the wavelength The spectrum of Uranine shows the highest sensitivity in a range from 450 to 480 nm. Here, lowest concentrations can be detected. This wavelengths can be set for spectrophotometers. Since Filter- or LED meters such as photoflex Series have restricted wavelengths availabilities, here 436 nm has been choosen to be the suitable wavelengths, The slightly lower sensitivity of the rising edge does not affect the measurement quality and allows calibration meters other than a spectrophotometer. Figure 2: Spectrum of Uranine in the range nm. Calculation of Concentration Assuming the characteristics curve of the method has a linear behaviour with positive slope, the calculation of concentrations follows the formula: c E E 0 F S concentration measured absorbance zero point of the method (also reagent blank) factor slope Method data There are different options to establish the photometric method data: 1. Direct measurement of the absorbance-/concentrationpair of variates and automatic calculation of the method data by the photometer including mean values for parallel standard samples. 2. Manual entry of the absorbance-/concentrationpair of variates and calculation of the method data by the photometer 3. Manual entry of already known method data in a predefined calculation formula 4. Entry of a known slope of the curve?! This document describes the procedure along point 2 via manual entry. 2

3 Standard solutions Fixing the measurement range on: 1 10 mg/l Uranine Preparation of 10 standard solution with 1 to 10 mg/l Uranine in ascending order with 1 mg/l steps. Figure 3: line of 10 standard solution in 100 ml graduated flasks. Absorbance measurements of the respective 10 standard solution at 436 nm. Performing a double or triple set of calibration standards increases the accuracy. To program the method, the mean value will be entered. concentration (mg/l) absorbance (A) 1 0, , , , , , , , , ,513 Programming of the new method Switch the meter on; waiting the heat up phase for best accuracy From the main menu of the photometer, selecteable with the [HOME] key, choose the [Concentration] measurement mode. Confirm with [START * ENTER] key. 3

4 Select [New Method] with the [F4] function key. In the [Edit method] display input data for characterization of the method. Essential information of the method is inserted here. Input is possible via the keypad of the photometer or via an external keyboard connected at the USB-A interface. Number Designation Version Wavelength Cell Citation form Unit Resolution Calibration curve Unique numbering in the method list. Next free will be offered automatically, but a manual selection between 1001 and 1100 is possible too. Name of the method within the method list. Version number. Wellenlänge für die Messung der Extinktionswerte für die Konzentrationsberechnung Type of cuvette for the measurement. Labelling of the result. Type of the dimension of the result. Decimal places of the result display. Different ways to calculate or input the method data are possible: - [Measurement of standard soluitons] - [Input of absorbance-/concentration pairs] - [Input a formula] [Measurement of standard solutions] For the calculation of method data required calibration points are measured and stored by the photometer as absorbances-/concentration pairs. [Input of absorbance-/concentration - pairs] Already known absorbance-/concentration pairs are inputtet manually. [Input a formula] Alreasy known coefficients can be insierted in the formula of a predefinied polynomial of maximum 5. grade. 4

5 Continue with The required absorbance-/concentration pairs will be determined from standard solutions of the concerning parameter. The concentration of the standard solutions are prepared constantly ascending in the desired measurement rang. To achieve a sufficient accuracy a minimum of 3 calibration points are required better 5. To follow standard methods, at least a 10-point-calibration should be performed. For an expected linear behaviour of the characteristics curve the choice of the concentration of the standard solutions can look like this: 3 calibration points: mg/l 5 calibration points: mg/l 10 calibration points: mg/l At this moment information belonging to the AQA are not required. The method can be edited later again. Manually input of absorbance-/concentration pairs of the 10-point-calibration via keypad. Function key [F4] assumes the entered data, in the next display the photometer shows the calculated method properties in a graphical presentation, which can be stored or printed to a PDF. (KOMMENTAR: CHECK) Several adjustments can be set in the last display. Alternatively, considering an optional sample blank value for later measurements, the option [reagent blank value required] can be set to yes. Key F4 complete the programming: 5

6 After completing the new method can be selected over the method list. Measurement performed: 6

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows Nitrate DOC316.53.01067 Cadmium Reduction Method Method 8192 0.01 to 0.50 mg/l NO 3 N (LR) Powder Pillows Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION Rate Law Determination of Crystal Violet Hydroxylation Revised 5/22/12 RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION Adapted from "Chemistry with Computers" Vernier Software, Portland OR, 1997

More information

NITROGEN, TOTAL, Test N Tube * Method 10071

NITROGEN, TOTAL, Test N Tube * Method 10071 NITROGEN, TOTAL, Test N Tube * Method 10071 TNT Persulfate Digestion Method (0 to 25.0 mg/l N) Scope and Application: For water and wastewater; digestion is required for determining total nitrogen. The

More information

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background Introduction Phenolphthalein is a dye that is used as an acid-base indicator. It is colorless in acidic or neutral solutions and turns bright red-violet (fuschia) as the solution becomes basic. In strongly

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law Vernier Spectrometer 1 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You

More information

NITROGEN, TOTAL, HR, Test N Tube

NITROGEN, TOTAL, HR, Test N Tube Method 10072 NITROGEN, TOTAL, HR, Test N Tube 10 to 150 mg/l N TNT Persulfate Digestion Method For water and wastewater Digestion is required for determining total nitrogen. The digestion procedure is

More information

Brooklyn College Department of Chemistry

Brooklyn College Department of Chemistry Brooklyn College Department of Chemistry Instrumental Analysis (Chem 42/790) Atomic Absorption Spectroscopy An atomic absorption spectrometer is used in this experiment to analyze a copper-base alloy for

More information

Investigating Food Dyes in Sports Beverages. Sample

Investigating Food Dyes in Sports Beverages. Sample Investigating Food Dyes in Sports Beverages Investigation 1 There are many different brands of beverages that fall under the general category of sports drinks. Most of these beverages contain an FD&C food

More information

Spectrophotometry Materials

Spectrophotometry Materials Spectrophotometry Materials Item per Class per Bench Genesys 10UV Spectrophotometer 6 1 13 ml test tubes box 7 Test tube racks 6 1 1% Albumin solution 25 ml/one flask 2 ml 0.7% Albumin solution (unknown

More information

SPECIALIZED LABORATORY of pharmaceuticals manufacturing

SPECIALIZED LABORATORY of pharmaceuticals manufacturing SPECIALIZED LABORATORY of pharmaceuticals manufacturing Department of organic technology (111) Solid dosage forms testing: Dissolution test Supervisors: Laboratory location: S25b Introduction Ensuring

More information

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials Nitrate, HR DOC316.53.01068 Chromotropic Acid Method Method 10020 0.2 to 30.0 mg/l NO 3 N (HR) Test N Tube Vials Scope and application: For water and wastewater. Test preparation Instrument-specific information

More information

DR/4000 PROCEDURE. IRON, Total

DR/4000 PROCEDURE. IRON, Total Method 8365 Powder Pillows DR/4000 PROCEDURE FerroMo Method* (0 to 1.800 mg/l) Scope and Application: For cooling water containing molybdate-based treatment; digestion is required for determining total

More information

Optical Reagent-Free Measurement of COD, Nitrate, Nitrite with photolab 7600

Optical Reagent-Free Measurement of COD, Nitrate, Nitrite with photolab 7600 Optical Reagent-Free Measurement of COD, Nitrate, Nitrite with photolab 7600 The Online Measurement transferred to the lab 2015 WTW GmbH, [June 2015] Juni 2015 Susanne Gollor From Online transferred to

More information

DR/4000 PROCEDURE NITRATE. 2. The display will show:

DR/4000 PROCEDURE NITRATE. 2. The display will show: Method 8192 Powder Pillows DR/4000 PROCEDURE Cadmium Reduction Method LR (0 to 0.50 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit for program number

More information

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy Rate Law Determination of the Crystal Violet Reaction Computer 30 In this experiment, you will observe the reaction between crystal violet and sodium hydroxide. One objective is to study the relationship

More information

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters) Nitrate, MR DOC316.53.01069 Cadmium Reduction Method Method 8171 0.1 to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters) Scope and application: For water, wastewater

More information

MEASUREMENT: PART II

MEASUREMENT: PART II 1 MEASUREMENT: PART II Copyright: Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, 2013. INTRODUCTION Read and/or review Section 1.7 and Figure 7.5 in your textbook. The first part

More information

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ ) DR/4000 PROCEDURE Method 8023 1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to 0.700 mg/l Cr 6+ ) Scope and Application: For water and wastewater;usepa accepted for reporting for

More information

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows Potassium DOC316.53.01127 Tetraphenylborate Method Method 8049 0.1 to 7.0 mg/l K Powder Pillows Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific information

More information

FLUORESCENCE APPLICATIONS

FLUORESCENCE APPLICATIONS FLUORESCENCE APPLICATIONS CORRECTION OF EMISSION SPECTRA USING THE PERKINELMER MODEL LS-50 LUMINESCENCE SPECTROMETER Spectra collected on luminescence spectrometers consist of true spectral information

More information

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013 Absorbance Experiment 13 Dilutions and Data Handling in a Spreadsheet rev 1/2013 GOAL: This lab experiment will provide practice in making dilutions using pipets and introduce basic spreadsheet skills

More information

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law The primary objective of this experiment is to determine the concentration of an unknown cobalt (II) chloride solution. You will use a Vernier SpectroVis

More information

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler Application Note Author John Sanders. Agilent Technologies, Inc. Mulgrave, Victoria 3170,

More information

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

DR/4000 PROCEDURE NITRATE. Using Powder Pillows DR/4000 PROCEDURE Method 8171 Powder Pillows or AccuVac Ampuls Cadmium Reduction Method MR (0 to 5.0 mg/l NO 3 N) Scope and Application: For water, wastewater and seawater. The estimated detection limit

More information

SILICA, Low Range SiLR

SILICA, Low Range SiLR SILICA, Low Range SiLR SP-910 Test Method Test Program Description:SP-910 Silica Low Range Method (0.02 1.60 ppm SiO 2 ) (Heteropoly Blue Method) Instruments and Reagents: Program 1. SP-910 Portable Water

More information

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline Experiment (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with,0- Phenanthroline Background The first step of an analytical spectrophotometric procedure for quantitative determination

More information

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer C101-E107B UV-3600 Shimadzu UV-VIS-NIR Spectrophotometer High sensitivity, high resolution, and an ultra-low stray-light level achieved with the latest technology lead the way to new solutions. UV-3600

More information

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water. Method 8337 Powder Pillows DR/4000 TT PROCEDURE QUATERNARY AMMONIUM COMPOUNDS Direct Binary Complex Method (0 to 5.00 mg/l as CTAB) Scope and Application: For cooling tower and pool/spa water. The estimated

More information

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC) METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC) 1.0 SCOPE AND APPLICATION 1.1 Method 7196 is used to determine the concentration of dissolved hexavalent chromium [Cr(VI)] in EP/TCLP characteristic extracts

More information

Determination of an Equilibrium Constant

Determination of an Equilibrium Constant Last updated 1/29/2014 - GES Learning Objectives Students will be able to: Determine the numerical value of an equilibrium constant from measured concentrations of all reaction species. Use an absorption

More information

Preparation of Standard Curves. Principle

Preparation of Standard Curves. Principle Preparation of Standard urves Principle Many laboratory tests require the measurement of concentration be evaluated or read in a photometer (colorimeter or spectrophotometer). Since these instruments are

More information

Lab 1 Uniform Motion - Graphing and Analyzing Motion

Lab 1 Uniform Motion - Graphing and Analyzing Motion Lab 1 Uniform Motion - Graphing and Analyzing Motion Objectives: < To observe the distance-time relation for motion at constant velocity. < To make a straight line fit to the distance-time data. < To interpret

More information

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS) The UV-VIS spectrometer is a portable ultraviolet light and visible light spectrophotometer, combining a spectrometer and a light source/cuvette

More information

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33 Photometer-System SC400 Colorimeter SiO 2 Silica DE GB FR IT ES Bedienungsanleitung Seite 3 17 Instruction Manual Page 19 33 d'emploi Page 35 49 Instruction Manual Istruzioni d'uso Pagina 51 65 Instrucciones

More information

FLAME PHOTOMETRY AIM INTRODUCTION

FLAME PHOTOMETRY AIM INTRODUCTION FLAME PHOTOMETRY AIM INTRODUCTION Atomic spectroscopy is based on the absorption, emission or fluorescence process of light by atoms or elementary ions. Information for atomic scale is obtained in two

More information

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3 , MR, 8171 DOC316.53.01069 Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3 N) Powder Pillows or AccuVac Ampuls Scope and Application: For water, wastewater and seawater Test preparation

More information

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1 Determining the Concentration of a Solution: Beer s Law Computer 17 The primary objective of this experiment is to determine the concentration of an unknown copper (II) sulfate solution. You will use a

More information

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832 , TNTplus 832, 10205 DOC316.53.01083 Salicylate Method Method 10205 HR (2 to 47 mg/l NH 3 N) TNTplus 832 Scope and Application: For surface waters, municipal and industrial wastewaters. Test preparation

More information

Chloramine (Mono) and Nitrogen, Free Ammonia

Chloramine (Mono) and Nitrogen, Free Ammonia Chloramine (Mono) and Nitrogen, Free Ammonia DOC316.53.01016 Indophenol Method 1 Method 10200 0.04 to 4.50 mg/l Cl 2 0.01 to 0.50 mg/l NH 3 N Powder Pillows Scope and application: For the determination

More information

Instructor s Advance Preparation

Instructor s Advance Preparation INSTRUCTOR'S MANUAL Instructor s Advance Preparation This protocol is designed for 80 workstations of 4 students. Each group will prepare a set of standards, a blank, and 2 milk samples (can be a blind

More information

Determining the Rate Law and Activation Energy for the Methyl Blue Reaction:

Determining the Rate Law and Activation Energy for the Methyl Blue Reaction: Experiment 4 Determining the Rate Law and Activation Energy for the Methyl Blue Reaction: Pre-lab Assignment Before coming to lab: Read the lab thoroughly. An exercise in experimental design Answer the

More information

The Plus for your lab!

The Plus for your lab! BioPhotometer plus NEW! analysis system The Plus for your lab! The easy, rapid and reliable BioPhotometer plus analysis system See it clearly! UVette Precision in plastics The patented* 1 UVette is the

More information

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1 EXPERIMET 14. ACID DISSOCIATIO COSTAT OF METHYL RED 1 The acid dissociation constant, Ka, of a dye is determined using spectrophotometry. Introduction In aqueous solution, methyl red is a zwitterion and

More information

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI Experiment 20 : Studying light absorption in terphenyl I. Background theory. 1. 2. 3. 4. 5. 6. 7. Electromagnetic

More information

Jasco V-670 absorption spectrometer

Jasco V-670 absorption spectrometer Laser Spectroscopy Labs Jasco V-670 absorption spectrometer Operation instructions 1. Turn ON the power switch on the right side of the spectrophotometer. It takes about 5 minutes for the light source

More information

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter Water and Lab Products, Thermo Fisher Scientific Technical Note 505 Key Words Thermo Scientific Orion

More information

Experiment 1 Chemical Kinetics 1

Experiment 1 Chemical Kinetics 1 Experiment 1 Chemical Kinetics 1 Purpose: Determine the rate law for the reaction of the dye crystal violet with hydroxide. Reading: Brown, et. al., Chemistry The Central Science, sections 14.1 14.4. Introduction

More information

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right. Barium DOC316.53.01315 Turbidimetric Method 1 Method 10251 2 to 100, 20 to 1000, 200 to 10,000 mg/l Ba (spectrophotometers) Powder Pillows 2 to 80, 20 to 800, 200 to 8000 mg/l Ba (colorimeters) Scope and

More information

SP-700 Free Chlorine Analysis TMB Method

SP-700 Free Chlorine Analysis TMB Method Data Sheet SP-700 Free Chlorine Analysis TMB Method The Pyxis SP-700 free chlorine method is based on the USEPA-accepted tetramethylbenzidine (TMB) chemistry for free chlorine analysis. The solidified

More information

A Study of Beer s Law Prelab

A Study of Beer s Law Prelab 1. What is the purpose of this experiment? A Study of Beer s Law Prelab 2. Using the absorbance versus wavelength curve given in Figure I, determine the approximate value of max of the dye used to construct

More information

Spectrometer User s Guide

Spectrometer User s Guide Spectrometer User s Guide (Order Codes: V-SPEC, SPRT-VIS, SP-VIS, SP-UV-VIS, ESRT-VIS) The spectrometer is a portable light spectrophotometer, combining a spectrometer and a light source/cuvette holder.

More information

Laboratory Measurements and Procedures

Laboratory Measurements and Procedures 18 Introduction Measurements of masses, volumes, and preparation of chemical solutions of known composition are essential laboratory skills. The goal of this exercise is to gain familiarity with these

More information

For simplicity, we ll represent BTB s ionization in a solution by the equilibrium: HBTB = H + + BTB -

For simplicity, we ll represent BTB s ionization in a solution by the equilibrium: HBTB = H + + BTB - Chemistry 160 Please have the following pages ready before class on Wednesday, April 11. An abstract (see the end of this handout) is needed for this write-up. The abstract and photocopied pages of the

More information

Concepts, Techniques. Concepts, Techniques 9/11/2012. & Beer s Law. For a simple, transparent, COLORED material, e.g. ROYGBV

Concepts, Techniques. Concepts, Techniques 9/11/2012. & Beer s Law. For a simple, transparent, COLORED material, e.g. ROYGBV 9//22 OBJECTIVES Spectrophotometry of Food Dyes & Beer s Law Last Update: 9//22 9:54 AM What is the quantitative basis for the color of substances? How is the absorption/transmission of light measured?

More information

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows FILL LINE Method 8155 Salicylate Method 1 Powder Pillows Scope and Application: For water, wastewater, and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) (0.01 to 0.50 mg/l NH 3 N) Test Preparation

More information

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Chem 1B Dr. White 11 Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III) Objectives To use spectroscopy to relate the absorbance of a colored solution to its concentration. To prepare a Beer s

More information

PAR Method Method to 2.0 mg/l Pb TNTplus 850

PAR Method Method to 2.0 mg/l Pb TNTplus 850 , TNTplus 850, 10216 DOC316.53.01056 PAR Method Method 10216 0.1 to 2.0 mg/l Pb TNTplus 850 Scope and Application: For wastewater and process control Test preparation Before starting the test: FOR DR 2800:

More information

Spectroscopic Method For Estimation of Atorvastatin Calcium in Tablet Dosage Form

Spectroscopic Method For Estimation of Atorvastatin Calcium in Tablet Dosage Form Spectroscopic Method For Estimation of Atorvastatin Calcium in Tablet Dosage Form Kailash P Prajapati *, A Bhandari INDO GLOBAL JOURNAL OF PHARMACEUTICAL SCIENCES ISSN 2249-1023 Faculty of Pharmaceutical

More information

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore Introduction to Spectroscopy: Analysis of Copper Ore Using a Buret and Volumetric Flask: 2.06 ml of solution 2.47 ml of solution 50.00 ml delivered delivered Volumetric Flask Reading a buret: Burets are

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant LabQuest 10 The equilibrium state of a chemical reaction can be characterized by quantitatively defining its equilibrium constant, Keq. In this experiment, you will determine the value of Keq for the reaction

More information

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law.

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law. The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law. Required Supplies & Costs: RGB LED; $1.95 Light Sensors; $3.95 ea 3-way switch; $6.54 3 ohm resistor;

More information

Kinetics of Crystal Violet Bleaching

Kinetics of Crystal Violet Bleaching Kinetics of Crystal Violet Bleaching Authors: V. C. Dew and J. M. McCormick* From Update March 12, 2013 with revisions Nov. 29, 2016 Introduction Chemists are always interested in whether a chemical reaction

More information

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows , 8326 Eriochrome Cyanine R Method 1 Scope and Application: For water 1 Adapted from Standard Methods for the Examination of Water and Wastewater. DOC316.53.01003 Method 8326 (0.006 to 0.250 mg/l Al 3+

More information

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution Chloride DOC316.53.01017 Mercuric Thiocyanate Method Method 8113 0.1 to 25.0 mg/l Cl Reagent Solution Scope and application: For water and wastewater. Test preparation Instrument-specific information Table

More information

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters) Aluminum DOC316.53.01002 Aluminon Method 1 Method 8012 0.008 to 0.800 mg/l Al 3+ (spectrophotometers) Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters) Scope and application: For water and wastewater.

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Chemistry 102 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium

More information

A new chapter. medicacorp.com

A new chapter. medicacorp.com A new chapter. \EDIC@ medicacorp.com Same operational reliability. Reliable performance, test after test. The photometer s xenon fl ash lamp typically has a 5-year use life and is maintenance-free. No

More information

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Determining the Concentration of a Solution: Beer s Law

Determining the Concentration of a Solution: Beer s Law Determining the Concentration of a Solution: Beer s Law LabQuest 11 The primary objective of this experiment is to determine the concentration of an unknown nickel (II) sulfate solution. You will be using

More information

A Computer Method for Separating Hard to Separate Dye Tracers

A Computer Method for Separating Hard to Separate Dye Tracers A Computer Method for Separating Hard to Separate Dye Tracers P.-A. Schnegg Abstract Tracer tests are an irreplaceable tool for hydrogeologists. They are used to determine the paths of water flow between

More information

Photosynthesis. LabQuest OBJECTIVES

Photosynthesis. LabQuest OBJECTIVES Photosynthesis LabQuest 4B The process of photosynthesis involves the use of energy to convert carbon dioxide and water into sugar, oxygen, and other organic compounds. This process is often summarized

More information

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows , 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows

More information

Basic Instrumentation. Learning Objectives:

Basic Instrumentation. Learning Objectives: Proteomics Basic Instrumentation Basic Instrumentation Handling instruments plays an important role in laboratory working on a daily basis. The use of most instruments is almost inevitable and hence a

More information

INTERNATIONAL OLIVE COUNCIL

INTERNATIONAL OLIVE COUNCIL INTERNATIONAL OLIVE COUNCIL COI/T.20/Doc. No 19/Rev. 4 2017 ENGLISH Original: ENGLISH Príncipe de Vergara, 154 28002 Madrid España Telef.: +34 915 903 638 Fax: +34 915 631 263 - e-mail: iooc@internationaloliveoil.org

More information

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats Application Note 24 Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats INTRODUCTION Most spectrophotometric

More information

Spectrophotometric Determination of pka of Phenol Red

Spectrophotometric Determination of pka of Phenol Red Spectrophotometric Determination of pka of Phenol Red This experiment uses instrumentation to accomplish quantitative analysis. You will get far more experience in this during CH427 if you are a Chemistry

More information

Density of Aqueous Sodium Chloride Solutions

Density of Aqueous Sodium Chloride Solutions Experiment 3 Density of Aqueous Sodium Chloride Solutions Prepared by Ross S. Nord and Stephen E. Schullery, Eastern Michigan University PURPOSE Determine the concentration of an unknown sodium chloride

More information

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore Introduction to Spectroscopy: Analysis of Copper Ore Using a Buret and Volumetric Flask: 2.06 ml of solution delivered 2.47 ml of solution delivered 50.00 ml Volumetric Flask Reading a buret: Burets are

More information

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows , 8155 Salicylate Method 1 Scope and Application: For water, wastewater and seawater 1 Adapted from Clin. Chim. Acta., 14, 403 (1966) DOC316.53.01077 Method 8155 0.01 to 0.50 mg/l NH 3 N Powder Pillows

More information

Recommended tools and devices: spectrophotometer Spekol, cuvettes, set of chromatic solutions varying in concentration, distilled water

Recommended tools and devices: spectrophotometer Spekol, cuvettes, set of chromatic solutions varying in concentration, distilled water 16_Spectrophotometry.xlsx/Work procedure Study group: Year of study: Objective: Establish the unknown concentration of a solutionusing absorption of light. Tasks: 1. Measure the absorbance and transmittance

More information

Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard Sodium Chloride - Analytical Standard Determination of Fluorides Former numbering: ECSS/CN 311-1982 & ESPA/CN-E-110-1994 1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes

More information

National standard of People s Republic of China

National standard of People s Republic of China National standard of People s Republic of China GB 5413.22 2010 National food safety standard Determination of phosphorus in foods for infants and young children, milk and milk products Issued on 2010-03-26

More information

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater. Nitrogen, Ammonia DOC316.53.01078 USEPA 1 Nessler Method 2 Method 8038 0.02 to 2.50 mg/l NH 3 N Reagent Solution Scope and application: For water, wastewater and seawater. Distillation is required for

More information

UV/VIS SPECTROMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

UV/VIS SPECTROMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT EXPERIMENT 8 UV/VIS SPECTROMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT A. Prelab Perform the experimental portion of the lab in groups of 68. Divide the work so everyone participates. You have one

More information

SPECTROPHOTOMETERS. Visible and UV-Visible

SPECTROPHOTOMETERS. Visible and UV-Visible Visible and UV-Visible The Manifacturer ONDA Spectrophotometers are manifactured by a company with over than ten years of experience in development of UV/Vis instruments, Single beam and Double beam, with

More information

EXPERIMENT 12 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of a Commercial Aspirin Tablet

EXPERIMENT 12 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of a Commercial Aspirin Tablet EXPERIMENT 12 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of a Commercial Aspirin Tablet utcomes After completing this experiment, the student should be able to: 1. Prepare standard

More information

TitriSoft 2.5. Content

TitriSoft 2.5. Content Content TitriSoft 2.5... 1 Content... 2 General Remarks... 3 Requirements of TitriSoft 2.5... 4 Installation... 5 General Strategy... 7 Hardware Center... 10 Method Center... 13 Titration Center... 28

More information

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method Rate law Determination of the Crystal Violet Reaction Using the Isolation Method Introduction A common challenge in chemical kinetics is to determine the rate law for a reaction with multiple reactants.

More information

CHEM Lab 7: Determination of an Equilibrium Constant using Spectroscopy

CHEM Lab 7: Determination of an Equilibrium Constant using Spectroscopy CHEM 0012 Lab 7: Determination of an Equilibrium Constant using Spectroscopy 1 Determination of the equilibrium constant of the following equilibrium system at room temperature. Fe 3+ (aq) + SCN- (aq)

More information

NanoDrop One Viewer software NanoDrop One Website. NanoDrop One Website NanoDrop One Viewer software NanoDrop One Website Software System Update Update Update Software, Update Note OK Language Measure

More information

Determination of Orthophosphate Ion

Determination of Orthophosphate Ion Determination of Orthophosphate Ion Introduction Phosphorous, in the form of phosphate, is one of several important elements in the growth of plants. Excessive algae growth in water is stimulated by the

More information

Quaternary Ammonium Compounds

Quaternary Ammonium Compounds , 8337 Quaternary Ammonium Compounds DOC316.53.01128 Direct Binary Complex Method Method 8337 0.2 to 5.0 mg/l as CTAB Powder Pillows Scope and Application: For cooling tower water and pool/spa water Test

More information

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

CH 112 Special Assignment #4 Chemistry to Dye for: Part C CH 112 Special Assignment #4 Chemistry to Dye for: Part C PRE-LAB ASSIGNMENT: Make sure that you read this handout and bring the essentials to lab with you. Review Light, energy and color (pp 17-18), Measuring

More information

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters) Chromium, Total DOC316.53.01034 Alkaline Hypobromite Oxidation Method 1 Method 8024 0.01 to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters) Scope and application: For water and wastewater.

More information

TL6 Ultra Micro-volume Spectrophotometer

TL6 Ultra Micro-volume Spectrophotometer TL6 Ultra Micro-volume Spectrophotometer TL6 is the latest Ultra Micro-volume Spectrophotometer of PERSEE ANALYTICS. It is a small portable instrument for fast analysis of nucleic acid and protein concentrations

More information

R-Biopharm AG RIDA CUBE SCAN. The smart analyser. Product Information. R-Biopharm for the safety of your analysis.

R-Biopharm AG RIDA CUBE SCAN. The smart analyser. Product Information. R-Biopharm for the safety of your analysis. R-Biopharm AG The smart analyser Product Information R-Biopharm for the safety of your analysis. Intended use The R-Biopharm is a new photometric system that allows biochemistry testing in small food laboratories

More information

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters) Silica DOC316.53.01132 Heteropoly Blue Method 1 Method 8186 0.010 to 1.600 mg/l SiO 2 (LR, spectrophotometers) Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters) Scope and application: For boiler

More information

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right. Nitrite DOC316.53.01074 USEPA Diazotization Method 1 Method 8507 0.002 to 0.300 mg/l NO 2 N (LR, spectrophotometers) 0.005 to 0.350 mg/l NO 2 N (LR, colorimeters) Scope and application: For water, wastewater

More information

Determining the Conductivity of Standard Solutions

Determining the Conductivity of Standard Solutions Determining the Conductivity of Standard Solutions by Anna Cole and Shannon Clement Louisiana Curriculum Framework Content Strand: Science as Inquiry, Physical Science Grade Level 11-12 Objectives: 1.

More information