Department of Engineering Science and Physics College of Staten Island. PHY315 Advanced Physics Laboratory. Lab Manuals

Size: px
Start display at page:

Download "Department of Engineering Science and Physics College of Staten Island. PHY315 Advanced Physics Laboratory. Lab Manuals"

Transcription

1 1 Department of Engineering Science and Physics College of Staten Island PHY315 Advanced Physics Laboratory Lab Manuals

2 2 Content Notes about this Lab Course Safety First! Lab Reports Lab Works 1. Basic Electrical Parameters of Semiconductors: Sheet Resistivity, Resistivity and Conduction Type. 2. Measuring Hall-Effect: Conductivity type, Concentration of Charge Carriers and Their Mobility. 3. Temperature Activation of Charge Carriers in Semiconductors: Measuring Bandgap Energy of Semiconductors. 4. Simulation of Ion Doping of Solids.

3 3 Notes about this Lab Course The experiments developed for this lab course PHY315 have been designed to expand on the material covered in lectures and to experimentally demonstrate the validity of physical principles. The manual describes 8 experiments and instructors will select the most important topics for experimental confirmation. The students would better understand the fundamentals of physics if they were able to experimentally see for themselves that the principles presented in the text are real, or pretty close to reality. It also important that through measuring and comparing the experimental results with analytical solutions and simulations the students become aware of the limitations of the analytical description of real physical processes. The present lab course Advanced Physics Laboratory PHY315 is a newly developed one. Therefore the feedback from student is extremely important for improving the design of experiments. The students are asked to give a brief assessment of the laboratory work in the lab reports. After each lab work, the students are invited to comment on ways to improve the experiment just completed. Students are also encouraged to propose topics they feel would benefit through experimental confirmation of principles discussed in class. Safety First! Safety is always an important topic whenever laboratory work is being considered, and it is certainly true in the case of PHY315 labs. Safety is important. Although the laboratory experiments use low voltages and low currents. However, the lab equipment is powered by the standard 110 V, 60 Hz line voltage. Be careful with the line voltages. Do not touch exposed prongs on the equipment plugs when connecting the equipment to the lines. Take care when using power supplies, which may be low voltage but can supply currents in the ampere range. Shorting such a supply can lead to a serious burn as current arc can ignite flammable materials. Some equipment is heavy enough to be generally stable on the bench. Be sure to keep the equipment away from the edges of the benches to avoid having a piece of equipment fall off the bench. Besides endangering people who might be struck, falling equipment endangers everyone in vicinity by stressing the power cords, possibly causing a line short or live fault on the equipment, not to mention damage to the expensive lab equipment. In general, electronic equipment does not survive harsh treatment. General Laboratory Rules 1. No eating, or drinking in the lab. 2. No use of cell phones in the lab. 3. Lab computers are for experiment use only. No web surfing, reading, or computer games allowed. 4. When finished using lab computer, put keyboard and mouse in the original place. 5. After the experiment is finished, the used equipment must be arranged in the way you found it. 6. Some equipment is required to be signed out and checked back in.

4 4 7. When leaving, clean up after yourself and leave your working lab desk in the state you found it. 8. If you need any assistance, ask your lab teacher, lab technician, or call Thank you for your co-operation! Lab Reports Scientists and engineers are most effective if they can clearly communicate their ideas and developments to others, both their colleagues and their managers. For this reason, writing and documenting are essential aspects of an engineer s/researcher's job. On average, experimentalists spend most of their time documenting their work and communicating the results to others. Many science and engineering students do not realize the importance of this documentation and communication process and have difficulties in their first job because of lack of skill in documenting their work. Scientists and engineers in the workplace are evaluated on their communication skills, which include both the quality and quantity of their publications and technical reports. In this lab class the students are required to prepare lab reports for each lab work. The lab report is the main document in which the student communicate the results of her/his experimental work, processing the experimental data and the conclusions made. The lab report is as important as the work itself done in the lab. Unless you can communicate the results of your work, the work has little usefulness. Furthermore, the lab report reinforces the material that was learned in the lecture class. Development of both oral and written technical communication skills is one of the most important things you can learn as an undergraduate student. General requirements Lab report should conform to the following guidelines. - Each report should be a self-contained document and should present all the information regarding the pre-experiment preparations, experimental work, measurements, obtained data, data processing, discussion and conclusions. - Each report is to be typed using a word processor. - Figures, drawings, charts, and tables should be added where they are needed and should contain understandable labels, including units for the axes of the graphs. - When plotting B vs. A, B is the dependent variable and is plotted on the y-axis, while A is the independent variable and is plotted on the x-axis. The figure should refer to the main text and should not stand alone. Except for raw data, all figures should be computer-drawn using any suitable plotting programs such as Origin or Excel.

5 5 - All pages should be consecutively numbered. Sign your report on the cover page. This signature shows that you take responsibility for what is contained in the report. Reports are due in a week after the experimental lab work has been finished. Lab report content 1. Title page the first separate page showing the student name, course and section numbers, lab title, date of the performance of experiment and the names of teammates. 2. Objectives - a short description (a few sentences) of the purpose and aim of the experiment. 3. Physical principles - a short description (up to one page) of the basic physical principles, definitions and relevant formulae describing the experiment and used for the processing of the obtained experimental data. 4. List of the experimental equipment used. 5. Experimental procedure - description of the major steps of performance of the experiment. 6. Laboratory data Sheet with the original experimental data preferentially arranged in tabular form. IMPORTANT: The lab data sheet of every student must be signed by the instructor at the end of the lab work session. The lab report without signed lab data sheet is not accepted. 7. Computations and graphs. This part of the report contains computations of the physical values and their experimental errors with indication of the corresponding units. Standard graph paper can be used for the graphical presentation of the experimental and calculated data. 8. Discussion. In this section, students discuss and analyze the obtained experimental data, results of calculations, graphs and the experimental errors. Discussion is the most creative and as such the important part of the lab report. Quality of the Discussion largely determines the grade of the lab report. 9. Conclusion, in which a statement is made as to whether the aim of the lab work has been achieved. In most cases, this statement is supported by the numerical data obtained. 10. Answers to the questions given at the end of every lab manual.

6 LAB WORKS 6

7 7 1. Basic Electrical Parameters of Semiconductors: Sheet Resistivity, Resistivity and Conduction Type. 1.1 Objectives 1. Familiarizing with experimental techniques used for the measurements of electrical properties of semiconductors. 2. Measurements of conductivity of doped low-ohmic semiconductors using Van der Pauw method. 3. Measurements of conductivity of high-ohmic intrinsic and compensated semiconductors by resistance method. 4. Determination of conductivity type of semiconductors by Hot-Probe method. 1.2 Principles The van der Pauw Method The Van der Pauw method is a technique commonly used to measure resistivity ρ, sheet resistance R S, concentration of majority charge carriers n, p (electrons, or holes) and their sign as well as mobility µ of charge carriers of semiconductor. The power of the van der Pauw method lies in its ability to accurately measure the properties of a thing sample of arbitrary shape. The method was first propounded by Leo J. van der Pauw in In order to use the van der Pauw method, the thickness of sample t must be much less than its width and length. It is preferable that the sample is symmetrical (Fig. 1.1). Fig Two common types of van der Pauw samples: clover leaf and square. Each sample has four symmetrical electrical contacts. The correct measurements require that four ohmic contacts are attached on the boundary of the sample. The contacts must be much smaller than the distance between them. In addition, the

8 8 leads connected to the contacts must be made of the same batch of wire to minimize thermoelectric effects. For the same reason, all four contacts should be of the same material. The contacts are numbered from 1 to 4 in a counter-clockwise order, beginning at the top-left contact. The voltages measured between contacts and the currents flowing between them are defined as following. For instance, the current I 12 is a positive DC current injected into contact 1 and taken out of contact 2, and is measured in amperes. The voltage V 34 is a DC voltage measured between contacts 3 and 4 (i.e. V 4 -V 3 ) with no externally applied magnetic field, measured in volts Resistivity measurements The average resistivity ρ of a sample can be calculated as a product of its sheet resistance R S and thickness t: ρ = R S t. (1) R S can be found measuring two Van der Pauw resistances along two perpendicular sides of square sample. Van der Pauw resistance is a ratio of the voltage applied across one edge of sample over the current generated along the opposite edge of the sample. For instance, R 41,23 is measured as voltage V 23 over current I 41 (Fig. 1.2). RR 4444,2222 = VV 2222 II 4444 (2) Fig Example of measuring Van der Pauw resistance. Voltage is applied along one side, while the generated current is measured along the opposite side. Picture shows the measurement of resistance R 41,23. Two perpendicular resistances which can be used for resistivity measurements are, for instance, R 12,34 and R 23,41. The sheet resistance can be determined from two of these resistances - one measured along a vertical edge, such as R vertical = R 12,34, and a corresponding one measured along a horizontal edge, such as R horizontal = R 23,41. The actual sheet resistance is related to these resistances by the van der Pauw equation: eeeeee ππrr vvvvvvvvvvvvvvvv + eeeeee ππrr hoooooooooooooooooo = 1 (3) RR SS RR SS

9 9 For symmetrical samples, e.g. square samples used in this lab work, R vertical = R horizontal = R and the equation (3) has simple solution: RR SS = ππrr ln2 In order to obtain a more precise value for the resistances, four Van der Pauw resistances for all four sides of the sample are measured and R is taken as average of these four resistances. (4) Resistance method Van der Pauw method is usually applied to doped semiconductors of moderate and low resistivity not exceeding 10 kω.cm. Resistivity of highly resistive semiconductors, e.g. undoped intrinsic silicon, can be conveniently determined measuring resistance of a rectangular sample (slab) made of this material. For a sample of length l, width w and thickness t, its resistance R is: RR = ρρ ll wwww Thus the resistivity ρ can be found as: ρρ = RR wwww ll The most correct measurements of resistance are performed by four-probe method. Current in the sample is generated applying voltage to the outer contacts on the slab while voltage is measured between the internal contacts. The length l in the Eq. 5 is the distance between the internal contacts. The advantage of the four-probe method, as compared with the two-probe method, is the exclusion of resistances of the contacts from the measurements. The contact resistances are usually unknown and, when comparable with the resistance of the sample, they may cause considerable experimental error. (5) (6) Hot-Probe method When a piece of semiconductor is heated non-uniformly, the charge carriers diffuse from hot region in cold one generating this way a voltage (thermo-voltage) between these regions (Fig. 1.3). Fig Generation of thermo-voltage between hot and cold ends of a semiconductor slab. Since sign of thermo-voltage corresponds to the sign of the diffusing charge carriers, the measurement of the voltage induced between hot and cold contacts on a piece of semiconductor is a simple way to determine its conductivity type. This measurement known as the "hot-probe" method provides a simple way to distinguish between n-type and p-type semiconductors and can

10 10 be easily demonstrated using a soldering iron and a standard multi-meter. The experiment is performed by contacting a semiconductor sample with a "hot" probe (tip of heated soldering iron) and a "cold" probe (regular contact). Both probes are wired to a sensitive volt-meter. The hot probe is connected to the positive terminal of the meter, while the cold probe is connected to the negative terminal. The experimental set-up is shown in Fig Fig Principle of experimental set-up of the "hot-probe" experiment Experimental Equipment - Two Van der Pauw samples of doped silicon (n-type and p-type) with holders - 1 bar sample of intrinsic silicon with holder - Various free standing samples of silicon - DC Power Supply - Digital ammeter - Digital voltmeter - Soldering Iron - Micrometer 1.4. Procedure Van der Pauw measurements 1. Assemble the measuring set-up as shown in Fig. 1.5 below.

11 11 Fig Schematics of the experimental circuit for the measurement of Van der Pauw resistance. 2. Measure Van der Pauw resistances along all sides of the n-type samples for both directions of current. 3. Calculate average Van der Pauw resistance and sheet resistivity of the sample using Eq Measure thickness of the samples using micrometer. 5. Calculate resistivity of the sample using Eq Repeat the measurements on the p-type Van der Pauw sample Resistance method 1. Assemble the measuring set-up as shown in Fig Fig Schematics of the experimental circuit for the electrical measurements using resistance method. 2. Apply voltage to the outer contacts of one of the intrinsic samples and measure current flowing through the sample. 3. Measure voltage between the internal contacts. 4. Calculate resistance dividing the measured voltage by the measured current.

12 12 5. Measure thickness of the sample, its width and the distance (length) between the internal contacts using micrometer or caliper. 6. Calculate resistivity of the sample using Eq Hot-Probe measurements 1. Connect digital voltmeter to the metal substrate and to the tip the soldering iron. 2. Place one of the samples on the substrate. 3. Switch on soldering iron and wait until it is hot. 4. Touch sample with the hot tip and immediately take reading of the voltmeter. Note the sign of the reading. 5. Repeat the measurements on another free-standing samples Procedure 1. Discuss the processes of measurements and the obtained results. 2. Compare values of resistivity measured by Van der Pauw and resistance methods. 3. Using standard values of mobility of electrons and holes in silicon, calculate concentrations of major charge carriers in the measured samples. 4. Discuss the results of your calculations. 5. Compare the data obtained by the van der Pauw and resistance methods Questions 1. Which of the methods used in this lab work is the most accurate? Why? 2. Why is the four-point measurement of resistance more accurate than the two-point one? 3. Predict the magnitude of mobility in the silicon samples you have measured. 4. How does thermo-voltage depend on concentration of charge carriers and mobility?

13 13 2. Hall-Effect in Semiconductors. Conduction type, Concentration of Charge Carriers and Their Mobility 2.1. Objectives 1. Familiarizing with the measurements of Hall-effect on semiconductors. 2. Measurement of concentration of majority charge carriers and their mobility in silicon Principles Charge carrier concentration and mobility can be found measuring Hall-effect on Van der Pauw sample placed in magnetic field. Magnetic field makes charge carriers to deviate from their straight drift between the contacts. This deviation results in generation of Hall voltage V H in the direction perpendicular to the direction of current flow (Fig. 2.1). Fig (a) Principle of measurement of Hall-effect. (b) Example of measurement of Hallvoltage V 42. Current is applied between contacts 3 and 1 (I 31 ), while voltage is measured between contacts 4 and 2. In order to measure Hall-voltage on Van der Pauw sample, two sets of measurements are made: one with magnetic field in the positive z-direction, and one with it in the negative z-direction. The voltages recorded with positive field will have a subscript P (such as, V 13, P = V 3, P - V 1, P ), whereas those recorded with negative field will have a subscript N (such as V 13, N = V 3, N - V 1, N ). For all of the measurements, the magnitude of the injected currents should be kept the same. The magnitude of the magnetic field must be the same in both directions also. Hall voltage is then calculated as: VV HH = VV 1111+VV VV VV 4444 ; (6) 88 V 13 = V 13, P V 13, N V 24 = V 24, P V 24, N V 31 = V 31, P V 31, N V 42 = V 42, P V 42, N

14 14 The polarity of the Hall voltage indicates the type of material the sample is made of. If it is positive, the material is p-type, and if it is negative, the material is n-type. When Hall-voltage V H is known, sheet concentration of charge carriers n S can be found as: IIII nn SS =, (7) ee VV HH where I is the current flowing along the sample and e is the electron charge. Density of the majority charge carriers n m and their mobility µ m can be found as: nn mm = nn SS tt = IIII ee VV HH tt, (8) µ mm = 11 eeee SS RR SS Experimental Equipment - Digital voltmeter - Digital ammeter - Holder with silicon van der Pauw samples - DC Power Supply - Permanent Co-Sm magnet of magnetic field strength B = 0.5 T 2.4. Procedure 1. Assemble the measurement set-up as shown in Fig Fig Schematics of the experimental circuit for the Hall-effect measurements using Van der Pauw method. 2. Place magnet over the silicon sample. 3. Apply ~5 ma current through one diagonal of the sample. This is the current I shown in formula (7) and (8). Measure voltage over the other perpendicular diagonal. Flip the magnet and repeat the measurement. Calculate difference between the measured voltages. The obtained value is the voltage V 13 in formula (6).

15 15 4. Reverse the direction of current and repeat the procedure 3. The obtained value is the voltage V 31 in formula (6). 5. Repeat the procedures 4 and 5 applying current to the other diagonal and measuring voltage over the perpendicular one. The obtained values are the voltages V 24 and V 42 correspondingly in formula (6). 6. Measure thickness of the silicon sample t Calculations and Discussion 1. Retrieve the data on Van der Pauw resistance R, sheet resistance R S and resistivity ρ of the extrinsic silicon samples you measured in lab work Calculate Hall-voltage V H using the voltages measured in procedures 4-6 and formulae (6). 3. Using the values of R, V H, t, I and B calculate density of the majority charge carriers n m, mobility of majority charge carriers µ m, sheet resistance R S and sheet carrier density n S. Determine type of the majority charge carriers: electrons, or holes. 4. Compare the obtained values with that known for the sample you measured and with that known for silicon used in electronic industry. 5. Discuss your measurements and the obtained results Questions 1. Is it possible to measure Hall-effect on intrinsic semiconductor? Explain your answer. 2. Is it possible to measure Hall-effect on compensated semiconductor? Explain your answer. 3. How temperature influences Hall-effect measurements? 3. Predict Hall-voltage on your samples when they would be measured at a temperature of 100 C. 4. Is it possible to measure Hall-effect on your samples at liquid nitrogen temperature? Support your answer with calculations of charge carrier concentration. Appendix (a) The intrinsic carrier density in silicon at 300 K equals:

16 (b) Table of the intrinsic carrier density in semiconductors at different temperatures. 16

17 17 3. Temperature Activation of Charge Carriers in Semiconductors. Bandgap Energy and Temperature Dependence of Mobility Objectives 1. Experimental measurements of conductance of intrinsic and doped semiconductors as a function of temperature, 2. Familiarizing with basic methods of measurement of bandgap energy of semiconductor and activation energies of donors and acceptors Principles Measuring Bandgap energy Conductance S of a piece of an undoped (intrinsic) semiconductor is proportional to the concentration of intrinsic charge carriers n i. The value of n i is determined by the thermal activation of electrons and holes over the bandgap: nn ii = NN CC NN VV eeeeee EE gg, (1) 2222 BB TT where N C and N V are densities of states in conduction and valence bands correspondingly, E g is the bandgap energy, k B is the Boltzmann constant and T is absolute temperature. Since N C and N V do not depend much on temperature, the temperature dependence of n i and consequently the temperature dependence of conductance S of intrinsic semiconductor is primarily determined by the exponential term in equation (1): SS = CCCCCCCC EE gg, (2) 2222 BB TT where C is a constant. By measuring conductance S 1 and S 2 at two different temperatures T 1 and T 2 one has a simple way to experimentally determine the value of the bandgap of semiconductor: EE gg SS 1 = CCCCCCCC, (3) 2kk BB TT 1 SS 2 = CCCCCCCC 2kk BB TT 2 SS 1 = eeeeee EE gg 1 1 = II 1 SS 2 2kk BB TT 1 TT 2 II 2 If a constant voltage is used for the measurements of conductance, the ratio of conductances S 1 /S 2 equals to the ratio of corresponding currents I 1 /I 2. Then the formula for calculation of the bandgap energy is: EE gg = 2kk BBllll II 1 II2. (4) 1 TT2 1 TT1 EE gg

18 Temperature dependence of mobility Conductance of doped semiconductors is primarily determined by the concentration of majority charge carriers electrons, n, or holes p. At room temperature and elevated temperatures, these concentrations approach N D and N A respectively: n N D and p N A. Since concentration of intrinsic charge carriers is much less than that delivered by dopants, conductance of doped semiconductors can be found as (5): SS nn = SS 0000 nnμμ nn, SS pp = SS 0000 ppμμ pp, (5) where S 0n and S 0p are constant geometrical factors of the samples measured and μ is mobility. In these formulae, the only parameter strongly dependent on temperature is the mobility. In the temperature range 100 to 400K, mobility drops with temperature: μ ~ T -3/2 (Fig. 3.1). Thus, measuring ratio of conductances S 1 and S 2 at different temperatures T 1 and T 2, one can verify the temperature dependence of mobility in doped semiconductors. Mobility, cm 2 /Vs Electrons ND1e12cm-3 ND1e16cm-3 ND1e17cm-3 a Mobility, cm 2 /Vs Holes NA1e12cm-3 NA1e16cm-3 NA1e17cm-3 b Temperature, K Temperature, K Fig Temperature dependence of mobility of electrons in n-type silicon (a) and holes in p- type silicon (b) for doping levels of cm -3, cm -3 and cm -3.

19 19 Fig Temperature dependence of electron concentration (a) and conductivity (b) of As-doped n-type silicon. Note that the electron concentration always grows with temperature, whereas the conductivity of low-doped silicon may considerably decrease with temperature from 100 to 400K Experimental Equipment - Two holders with Wan der Pauw samples of n-type and p-type silicon - One holder with bar sample of intrinsic silicon - DC Power Supply - Digital voltmeter - Digital ammeter - Hot plate - Thermocouple - 1 beaker with boiling water - 1 beaker with dry ice 3.4. Procedure 1. Assemble the measuring circuit with the bar sample of intrinsic silicon as shown in Fig While performing the measurements, place sample with thermocouple inside a test-tube submerged in the boiling water to slowly heat it to about 100 C. It may not reach exactly boiling point because it is isolated inside the test-tube. 3. After reaching maximum temperature, take out the sample and allow it to cool to room temperature.

20 20 4. Once the sample is back at room temperature, cool it in beaker with dry ice to about -60 C. 5. Once again remove the sample and allow it to warm up to room temperature. 6. Export the graph to Excel and process data as needed. The combination of heating and cooling curves in one graph will remove any error from hysteresis. 7. Repeat the procedures 1 to 8 for n-type silicon and p-type silicon Calculations and Discussion 1. Using the data obtained from the intrinsic silicon sample. Process data to plot ln(ii) vvvv 1 and TT find the slope. Formula (2) describes this relationship and can be used to calculate bandgap energy of silicon. 2. Compare the obtained value of the bandgap energy. Theoretically, the slope must be constant. If it deviates considerably calculate the magnitude of the deviation. Compare this value of bandgap energy with the known value of E g = 1.12 ev for silicon. 3. Discuss the process of measurements, your results and possible reasons of deviation of the measured values of bandgap energy from the known one. 4. Using the data obtained from doped silicon samples, process the data to plot lg(i) versus lg(t) and find the slope. This slope is negative and its value should be about Discuss the obtained values in terms of conductivity and compare them with the temperature change of mobility shown in Fig. 1 and with the temperature change of conductivity shown in Fig Questions 1. Using your experimentally obtained values of E g, predict the conductance of the bar sample at the temperature of liquid nitrogen (-195 C) and maximum working range of devices (120 C). 2. At what temperature the conductance of the intrinsic silicon sample would be equal to the room temperature conductance of the doped silicon samples? 3. Is it possible within this lab work to measure conductivity and sheet resistance of the silicon samples? 4. Is it possible within this lab work to measure concentration of donors and acceptors in the doped silicon samples?

21 21 4. Simulation of Ion Doping of Semiconductors 4.1. Objectives - To give students hand-on experience of numerical simulation of ion doping used for fabrication of semiconductor electronic structures. - To familiarize students with SRIM software used for numerical simulation of ion doping. - To perform numerical simulation of ion doping of planar bipolar transistor Principles Parameters of ion-doped layer Ion implantation is the main doping method used for fabrication of in microelectronic devices. Over all, it is the most precise and controllable method of impurity doping of solids. In ion implantation, impurity toms are introduced into semiconductor substrate by ionizing them (creating ions), accelerating the ions to energies ranging from kiloelectronvolt (kev) to megaelectronvolt (MeV), and then literally shooting these ions onto the substrate surface (Fig. 4.1). Accelerated ions Ions stopped by mask Mask Mask Ion-doped P + region ion doping Si substrate Fig Principle of local doping of semiconductor using ion implantation and masking technique. Openings in the mask define the ion-doped areas. Mask must be thick enough to protect the masked areas from doping. Ions penetrate into semiconductor substrate to a certain doping depth R i. This way a buried ion doped layer is created. Distribution of density of the implanted ions N(x) through the depth x is not uniform. It is approximately described by a Gaussian function (1):

22 22 NN(xx) = NN ii RR 2ππ ee (xx RR dd) 2 /2 RR pp (1) Thus the distribution of ions through the depth on the implanted layer is described by a broad peak, the parameters of which are the maximum concentration N i located below the surface at a depth R p (the projected range) and the spread R p (implantation straggle) (Fig. 4.2). Fig Depth distribution of boron ions implanted into silicon with equal dose cm -2, but at different energies. Depth of the doped layer and its width (2 R p ) increase with the implantation energy. Projected range R p and straggling R p are shown for 400 kev ions. R p The doping depth R i primarily depends on the mass of the implanted ions, their energy and the chemical composition of the substrate. It is roughly proportional to the ion energy and inversely proportional to the ion mass. The ion-doped layer is buried under the substrate surface. The average depth of the doped layer is R p, and its effective width is 2 R p. In order to dope selected areas, masking technique is used. Mask covers the areas which must remain undoped. The openings in the mask define the areas of ion doping (Fig. 4.1). The mask must be thick enough to stop the ions completely and prevent from doping in the masked areas. Using ion implantation, layers doped with donors (e.g. phosphorous ions, P + ) and acceptors (e.g. boron ions, B + ) can be created. Using multiple implantations with appropriate energies through corresponding masks a multilayer doped structures can be made. Fig. 4.3 shows an example of three layer ion-doped structure of bipolar transistor. Fig Structure of planar bipolar transistor made by two implantations of B + ions and one implantation of P + ions.

23 Numerical simulation of ion doping with SRIM computer code Stopping and Range of Ions in Matter (SRIM) is a group of computer programs which calculate interaction of ions with matter. The essential program of these is Transport of Ions in Matter (TRIM). SRIM is very popular in the ion implantation research and technology community. The programs were developed by J. F. Ziegler and J. P. Biersack around 1983 and are being continuously upgraded. SRIM is based on a Monte Carlo simulation method, namely the binary collision approximation with a random selection of the impact parameter of the next colliding ion. The main output data of the SRIM simulation used in this lab work are three-dimensional distribution of the implanted ions and the implantation induced damage. The output data of simulation can be viewed in plots (while the calculation is proceeding) and also in detailed numerical files. The plots are especially useful to see if the calculation is proceeding as expected, but are usually limited in resolution. Most of the data files can be requested in the Setup Window for TRIM (menus at the bottom of the window), or can be requested during the calculation. All calculated averages are made over the entire calculation. Simulation of fabrication of planar bipolar p-n-p structure Simulation of ion doping of p-n-p structure starts with the calculation of the depth distribution of boron acceptors in the deepest p-type collector layer. Energy of the boron ions and the ion dose are chosen so that they ensure formation of the collector layer at the required depth with the required concentration of acceptors. An example is shown in Fig Collector layer is formed at a depth range from 260 to 500 nm by implantation of 100 kev B + ions (Fig. 4.4a). The maximum acceptor concentration of cm -3 is achieved at a depth of 350 nm (collector depth R C ). The second step is the simulation of formation of the phosphorous-doped n-type base layer. The energy of P + ions and their dose have to be adjusted so that the distribution of the implanted phosphorous overlaps with the boron distribution in the collector layer only partially. The maximum concentration in the phosphorous-doped layer must correspond to the required density of donors in the base layer. In the depth range of overlapping, boron acceptors and phosphorous donors compensate each other. At the depth R CB, where the boron and phosphorous concentrations are equal, complete compensation occurs. At this depth the collector-base p-n junction is formed. In Fig. 4.5a the base layer is formed at depths from 10 to 250 nm by implantation of 130 kev P + ions. The maximum donor concentration in the base layer is about cm -3 at a depth of 180 nm (base depth R B ). Collector-base junction is formed at a depth of 260 nm (R CB ). Once R CB is determined, the simulation of the boron ion doping of the emitter layer is performed. The ion energy and dose are to be adjusted so that the emitter boron-doped layer has the required acceptor concentration and forms the emitter-base p-n junction at the required depth R EB. The emitter layer in Fig. 4.4b is formed by 25 kev B + ion implantation. The maximum acceptor concentration in the emitter layer is about cm -3 at a depth of 110 nm (emitter depth R E ) The emitter-base junction is formed at a depth of 160 nm (R EB ).

24 24 6.0x10 17 B 100 kev 1.2x10 18 B 25 kev Boron Concentration, cm x x10 17 Boron Concentration, cm x x Depth (nm) Depth (nm) Fig Depth distribution of ion-implanted boron. (a) Implantation of 100 kev boron ions. (b) Implantation of 25 kev boron ions. Phosphorous concentration, cm x x x x x Depth (nm) P 130 kev Dopant Concentration, cm x x x x x x10 17 Boron Phosphorous Boron Depth (nm) Fig (a) Depth distribution of ion-implanted phosphorous. (b) Distribution of implanted boron and phosphorous plotted on one graph. There is considerable overlapping of the distribution profiles.

25 25 1.0x10 18 EB junction 8.0x10 17 Concentration, cm x x x10 17 p n BC junction p Depth, nm Fig Distribution of non-compensated boron acceptors (blue) and non-compensated phosphorous donors (red). Position of p-n junctions are shown with arrows. The ion dose which is required to achieve maximum concentration N max is calculated using formula: NN(xx) = NN ii RR 2ππ ee (xx RR dd) 2 /2 RR pp (2) 4.3. Procedure 1. Open SRIM simulation program. Open Stopping/Range Table option. Generate table of projected ranges and stragglings for boron ions. Determine ion energy E C corresponding to the chosen collector depth, e.g. R C = 400 nm. This depth corresponds to the projected range R pc of the boron ions in the collector layer. 2. Perform simulation of implantation of silicon with boron ions of energy E C. Obtain value of straggling R pc for the collector layer. Save the simulation data. 3. Calculate difference R CB = R pc - R pc. This is an approximate depth of the CB junction. 4. In the Stopping/Range Table option, generate table of projected ranges and stragglings for phosphorous ions. Determine energy E B of P + ions, for which R pb + R pb R CB. This is the energy of phosphorous ions implanted into base layer. 5. Perform simulation of implantation of silicon with phosphorous ions of energy E B. Obtain value of straggling R pc for the base layer. Save the simulation data. 6. Calculate difference R EB = R pb - R pb. This is an approximate depth of the EB junction.

26 26 7. In the table of projected ranges and stragglings for B + ions find the energy of boron ions E E, for which R pe + R pe R EB. This is the energy for boron ions implanted into emitter layer. 8. Perform two separate simulations of implantation in silicon of boron ions with the energies E C and E E. Perform simulation of implantation in silicon of phosphorous ions with the energy E B. Save the simulation data. 9. Plot the obtained three simulation profiles on one graph in coordinates Ion Concentration versus Depth. 10. Adjust each simulation profile so that the maximum concentrations correspond to the chosen values: e.g. N Cmax = cm -3, N Bmax = cm -3, and N Emax = cm Sum up the boron concentration profiles and subtract the phosphorous concentration profile. The depths where the total concentration is zero (complete compensation) are the junction depths. 12. Using the values of N C, N B and N E calculate the ion doses D C, D B and D E, which are required to achieve these concentrations Calculations and Discussion 1. Discuss the obtained distributions of acceptors and donors over the depth of the transistor structure. 2. Compare the nominal depths of the CB and EB junctions found from Stopping/Range Tables with those obtained from the simulation profiles of implanted ions. 3. Calculate average concentrations of acceptors and donors in collector, base and emitter layers. 4. Using the data obtained, predict conductivity of the collector, base and emitter layers. 4.5 Questions 1. Predict maximum voltage which can be applied to the terminals of your simulated transistor. 2. How you would change the parameters of ion doping in order to: a) reduce the width of the base layer? b) decrease the resistance of collector and emitter?

Accelerated ions. ion doping

Accelerated ions. ion doping 30 5. Simulation of Ion Doping of Semiconductors 5.1. Objectives - To give students hand-on experience of numerical simulation of ion doping used for fabrication of semiconductor planar devices. - To familiarize

More information

Lab 3. Ion Implantation

Lab 3. Ion Implantation 1 Lab 3. Ion Implantation (SRIM 2008/2013 computer simulation) 1. Objectives - To give students hand-on experience of numerical simulation of ion doping used for fabrication of semiconductor nanodevices.

More information

Fig. 1. Two common types of van der Pauw samples: clover leaf and square. Each sample has four symmetrical electrical contacts.

Fig. 1. Two common types of van der Pauw samples: clover leaf and square. Each sample has four symmetrical electrical contacts. 15 2. Basic Electrical Parameters of Semiconductors: Sheet Resistivity, Resistivity and Conduction Type 2.1 Objectives 1. Familiarizing with experimental techniques used for the measurements of electrical

More information

Lab1. Resolution and Throughput of Ion Beam Lithography.

Lab1. Resolution and Throughput of Ion Beam Lithography. 1 ENS/PHY463 Lab1. Resolution and Throughput of Ion Beam Lithography. (SRIM 2008/2013 computer simulation) Objective The objective of this laboratory work is to evaluate the exposure depth, resolution,

More information

UMEÅ UNIVERSITY Department of Physics Agnieszka Iwasiewicz Leif Hassmyr Ludvig Edman SOLID STATE PHYSICS HALL EFFECT

UMEÅ UNIVERSITY Department of Physics Agnieszka Iwasiewicz Leif Hassmyr Ludvig Edman SOLID STATE PHYSICS HALL EFFECT UMEÅ UNIVERSITY Department of Physics 2004-04-06 Agnieszka Iwasiewicz Leif Hassmyr Ludvig Edman SOLID STATE PHYSICS HALL EFFECT 1. THE TASK To measure the electrical conductivity and the Hall voltage for

More information

Charge carrier density in metals and semiconductors

Charge carrier density in metals and semiconductors Charge carrier density in metals and semiconductors 1. Introduction The Hall Effect Particles must overlap for the permutation symmetry to be relevant. We saw examples of this in the exchange energy in

More information

Last Revision: August,

Last Revision: August, A3-1 HALL EFFECT Last Revision: August, 21 2007 QUESTION TO BE INVESTIGATED How to individual charge carriers behave in an external magnetic field that is perpendicular to their motion? INTRODUCTION The

More information

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics. Physical Structure of Matter Solid-state Physics, Plasma Physics Hall effect in p-germanium with Cobra3 What you can learn about Semiconductor Band theory Forbidden zone Intrinsic conductivity Extrinsic

More information

After successfully completing this laboratory assignment, including the assigned reading, the lab

After successfully completing this laboratory assignment, including the assigned reading, the lab University of California at Santa Cruz Jack Baskin School of Engineering Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 6: Temperature Dependence of Semiconductor Conductivity

More information

Electrical Resistance

Electrical Resistance Electrical Resistance I + V _ W Material with resistivity ρ t L Resistance R V I = L ρ Wt (Unit: ohms) where ρ is the electrical resistivity 1 Adding parts/billion to parts/thousand of dopants to pure

More information

Ion Implantation ECE723

Ion Implantation ECE723 Ion Implantation Topic covered: Process and Advantages of Ion Implantation Ion Distribution and Removal of Lattice Damage Simulation of Ion Implantation Range of Implanted Ions Ion Implantation is the

More information

Empirical Gas Laws (Parts 1 and 2) Pressure-volume and pressure-temperature relationships in gases

Empirical Gas Laws (Parts 1 and 2) Pressure-volume and pressure-temperature relationships in gases Empirical Gas Laws (Parts 1 and 2) Pressure-volume and pressure-temperature relationships in gases Some of the earliest experiments in chemistry and physics involved the study of gases. The invention of

More information

Semiconductor Physics Problems 2015

Semiconductor Physics Problems 2015 Semiconductor Physics Problems 2015 Page and figure numbers refer to Semiconductor Devices Physics and Technology, 3rd edition, by SM Sze and M-K Lee 1. The purest semiconductor crystals it is possible

More information

Physical Structure of Matter. Hall effect in p-germanium Solid-state Physics, Plasma Physics. What you need:

Physical Structure of Matter. Hall effect in p-germanium Solid-state Physics, Plasma Physics. What you need: Solid-state Physics, Plasma Physics Physical Structure of Matter What you can learn about Semiconductor Band theory Forbidden zone Intrinsic conductivity Extrinsic conductivity Valence band Conduction

More information

Introduction to Semiconductor Devices

Introduction to Semiconductor Devices Physics 233 Experiment 48 Introduction to Semiconductor Devices References 1. G.W. Neudeck, The PN Junction Diode, Addison-Wesley MA 1989 2. Background notes (Appendix A) 3. Specification sheet for Diode

More information

SEMICONDUCTOR BEHAVIOR AND THE HALL EFFECT

SEMICONDUCTOR BEHAVIOR AND THE HALL EFFECT 5 Feb 14 Semi.1 SEMICONDUCTOR BEHAVIOR AND THE HALL EFFECT The object of this experiment is to study various properties of n- and p-doped germanium crystals. The temperature dependence of the electrical

More information

Magnetic Force and Current Balance

Magnetic Force and Current Balance Pre-Lab Quiz / PHYS 224 Magnetic Force and Current Balance Name Lab Section 1. What do you investigate in this lab? 2. Consider two parallel straight wires carrying electric current in opposite directions

More information

HALL EFFECT IN SEMICONDUCTORS

HALL EFFECT IN SEMICONDUCTORS Warsaw University of Technology Faculty of Physics Physics Laboratory I P Andrzej Kubiaczyk 30 HALL EFFECT IN SEMICONDUCTORS 1. ackground 1.1. Electron motion in electric and magnetic fields A particle

More information

Introduction to Semiconductor Devices

Introduction to Semiconductor Devices Physics 233 Experiment 48 Introduction to Semiconductor Devices References 1. G.W. Neudeck, The PN Junction Diode, Addison-Wesley MA 1989 2. Background notes (Appendix A) 3. Specification sheet for Diode

More information

Semiconductor Physics fall 2012 problems

Semiconductor Physics fall 2012 problems Semiconductor Physics fall 2012 problems 1. An n-type sample of silicon has a uniform density N D = 10 16 atoms cm -3 of arsenic, and a p-type silicon sample has N A = 10 15 atoms cm -3 of boron. For each

More information

Experiment 2 Deflection of Electrons

Experiment 2 Deflection of Electrons Name Partner(s): Experiment 2 Deflection of Electrons Objectives Equipment Preparation Pre-Lab To study the effects of electric fields on beams of fast moving electrons. Cathode-ray tube (CRT), voltage

More information

Lecture 1. OUTLINE Basic Semiconductor Physics. Reading: Chapter 2.1. Semiconductors Intrinsic (undoped) silicon Doping Carrier concentrations

Lecture 1. OUTLINE Basic Semiconductor Physics. Reading: Chapter 2.1. Semiconductors Intrinsic (undoped) silicon Doping Carrier concentrations Lecture 1 OUTLINE Basic Semiconductor Physics Semiconductors Intrinsic (undoped) silicon Doping Carrier concentrations Reading: Chapter 2.1 EE105 Fall 2007 Lecture 1, Slide 1 What is a Semiconductor? Low

More information

Semiconductor Devices and Circuits Fall Midterm Exam. Instructor: Dr. Dietmar Knipp, Professor of Electrical Engineering. Name: Mat. -Nr.

Semiconductor Devices and Circuits Fall Midterm Exam. Instructor: Dr. Dietmar Knipp, Professor of Electrical Engineering. Name: Mat. -Nr. Semiconductor Devices and Circuits Fall 2003 Midterm Exam Instructor: Dr. Dietmar Knipp, Professor of Electrical Engineering Name: Mat. -Nr.: Guidelines: Duration of the Midterm: 1 hour The exam is a closed

More information

Review of Semiconductor Fundamentals

Review of Semiconductor Fundamentals ECE 541/ME 541 Microelectronic Fabrication Techniques Review of Semiconductor Fundamentals Zheng Yang (ERF 3017, email: yangzhen@uic.edu) Page 1 Semiconductor A semiconductor is an almost insulating material,

More information

6.012 Electronic Devices and Circuits

6.012 Electronic Devices and Circuits Page 1 of 1 YOUR NAME Department of Electrical Engineering and Computer Science Massachusetts Institute of Technology 6.12 Electronic Devices and Circuits Exam No. 1 Wednesday, October 7, 29 7:3 to 9:3

More information

Introduction to Semiconductor Physics. Prof.P. Ravindran, Department of Physics, Central University of Tamil Nadu, India

Introduction to Semiconductor Physics. Prof.P. Ravindran, Department of Physics, Central University of Tamil Nadu, India Introduction to Semiconductor Physics 1 Prof.P. Ravindran, Department of Physics, Central University of Tamil Nadu, India http://folk.uio.no/ravi/cmp2013 Review of Semiconductor Physics Semiconductor fundamentals

More information

Lecture 3 Transport in Semiconductors

Lecture 3 Transport in Semiconductors EE 471: Transport Phenomena in Solid State Devices Spring 2018 Lecture 3 Transport in Semiconductors Bryan Ackland Department of Electrical and Computer Engineering Stevens Institute of Technology Hoboken,

More information

Charge to Mass Ratio of The Electron

Charge to Mass Ratio of The Electron Physics Topics Charge to Mass Ratio of The Electron If necessary, review the following topics and relevant textbook sections from Serway / Jewett Physics for Scientists and Engineers, 9th Ed. Electric

More information

Semiconductor Physics

Semiconductor Physics Semiconductor Physics Motivation Is it possible that there might be current flowing in a conductor (or a semiconductor) even when there is no potential difference supplied across its ends? Look at the

More information

UNIVERSITY OF CALIFORNIA, BERKELEY College of Engineering Department of Electrical Engineering and Computer Sciences

UNIVERSITY OF CALIFORNIA, BERKELEY College of Engineering Department of Electrical Engineering and Computer Sciences UNIVERSITY OF CALIFORNIA, BERKELEY College of Engineering Department of Electrical Engineering and Computer Sciences EE 105: Microelectronic Devices and Circuits Spring 2008 MIDTERM EXAMINATION #1 Time

More information

Quiz #1 Practice Problem Set

Quiz #1 Practice Problem Set Name: Student Number: ELEC 3908 Physical Electronics Quiz #1 Practice Problem Set? Minutes January 22, 2016 - No aids except a non-programmable calculator - All questions must be answered - All questions

More information

n i exp E g 2kT lnn i E g 2kT

n i exp E g 2kT lnn i E g 2kT HOMEWORK #10 12.19 For intrinsic semiconductors, the intrinsic carrier concentration n i depends on temperature as follows: n i exp E g 2kT (28.35a) or taking natural logarithms, lnn i E g 2kT (12.35b)

More information

Contact resistance and TLM measurements

Contact resistance and TLM measurements Contact resistance and TLM measurements In measuring resistance with the four-point-probe or van der Pauw methods, we used 4 contacts (2 for current, 2 for voltage) to determine the sheet resistance of

More information

Coulomb s Law and Coulomb s Constant

Coulomb s Law and Coulomb s Constant Pre-Lab Quiz / PHYS 224 Coulomb s Law and Coulomb s Constant Your Name: Lab Section: 1. What will you investigate in this lab? 2. Consider a capacitor created when two identical conducting plates are placed

More information

Experiment 3. Electrical Energy. Calculate the electrical power dissipated in a resistor.

Experiment 3. Electrical Energy. Calculate the electrical power dissipated in a resistor. Experiment 3 Electrical Energy 3.1 Objectives Calculate the electrical power dissipated in a resistor. Determine the heat added to the water by an immersed heater. Determine if the energy dissipated by

More information

Equipotential Lines and Electric Fields

Equipotential Lines and Electric Fields Physics Equipotential Lines and Electric Fields Plotting the Electric Field MATERIALS AND RESOURCES EACH GROUP 5 alligator clip leads 2 batteries, 9 V 2 binder clips, large computer LabQuest multimeter,

More information

1 Name: Student number: DEPARTMENT OF PHYSICS AND PHYSICAL OCEANOGRAPHY MEMORIAL UNIVERSITY OF NEWFOUNDLAND. Fall :00-11:00

1 Name: Student number: DEPARTMENT OF PHYSICS AND PHYSICAL OCEANOGRAPHY MEMORIAL UNIVERSITY OF NEWFOUNDLAND. Fall :00-11:00 1 Name: DEPARTMENT OF PHYSICS AND PHYSICAL OCEANOGRAPHY MEMORIAL UNIVERSITY OF NEWFOUNDLAND Final Exam Physics 3000 December 11, 2012 Fall 2012 9:00-11:00 INSTRUCTIONS: 1. Answer all seven (7) questions.

More information

EXPERIMENT 14. HALL EFFECT AND RESISTIVITY MEASUREMENTS IN DOPED GAAS 1. Hall Effect and Resistivity Measurements in Doped GaAs

EXPERIMENT 14. HALL EFFECT AND RESISTIVITY MEASUREMENTS IN DOPED GAAS 1. Hall Effect and Resistivity Measurements in Doped GaAs EXPERIMENT 14. HALL EFFECT AND RESISTIVITY MEASUREMENTS IN DOPED GAAS 1 Experiment 14 Hall Effect and Resistivity Measurements in Doped GaAs Note: This laboratory manual is based on a manual for a very

More information

Electric Currents. Resistors (Chapters 27-28)

Electric Currents. Resistors (Chapters 27-28) Electric Currents. Resistors (Chapters 27-28) Electric current I Resistance R and resistors Relation between current and resistance: Ohm s Law Resistivity ρ Energy dissipated by current. Electric power

More information

Experiment The Hall Effect Physics 2150 Experiment No. 12 University of Colorado

Experiment The Hall Effect Physics 2150 Experiment No. 12 University of Colorado Experiment 12 1 Introduction The Hall Effect Physics 2150 Experiment No. 12 University of Colorado The Hall Effect can be used to illustrate the effect of a magnetic field on a moving charge to investigate

More information

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences. Fall Exam 1

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences. Fall Exam 1 UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences EECS 143 Fall 2008 Exam 1 Professor Ali Javey Answer Key Name: SID: 1337 Closed book. One sheet

More information

Chap. 11 Semiconductor Diodes

Chap. 11 Semiconductor Diodes Chap. 11 Semiconductor Diodes Semiconductor diodes provide the best resolution for energy measurements, silicon based devices are generally used for charged-particles, germanium for photons. Scintillators

More information

Experiment 11: Hall Effect & Energy Gap in Germanium

Experiment 11: Hall Effect & Energy Gap in Germanium Experiment 11: Hall Effect & Energy Gap in Germanium We will see if the charge carrying particles are negative in n-doped germanium, and if they are positive in p-doped germanium. We will also measure

More information

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. MAGNETIC DEFLECTION OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. THEORY: Moving charges exert forces on one another that are not observed

More information

Fall 2014 Nobby Kobayashi

Fall 2014 Nobby Kobayashi University of California at Santa Cruz Jack Baskin School of Engineering Electrical Engineering Department EE-145L: Properties of Materials Laboratory Lab 5: Temperature Dependence of Semiconductor Conductivity

More information

ADVANCED UNDERGRADUATE LABORATORY EXPERIMENT 20. Semiconductor Resistance, Band Gap, and Hall Effect

ADVANCED UNDERGRADUATE LABORATORY EXPERIMENT 20. Semiconductor Resistance, Band Gap, and Hall Effect ADVANCED UNDERGRADUATE LABORATORY EXPERIMENT 20 Semiconductor Resistance, Band Gap, and Hall Effect Revised: November 1996 by David Bailey March 1990 by John Pitre & Taek-Soon Yoon Introduction Solid materials

More information

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE Concepts: Density Equipment Calibration Approximate time required: 90 minutes for density 90 minutes for two thermometers

More information

Name Partner. Thermal Physics. Part I: Heat of Vaporization of Nitrogen. Introduction:

Name Partner. Thermal Physics. Part I: Heat of Vaporization of Nitrogen. Introduction: Name Partner Thermal Physics Part I: Heat of Vaporization of Nitrogen Introduction: The heat of vaporization of a liquid, L v, is the energy required to vaporize (boil) a unit mass of substance. Thus if

More information

Lab 12 Pressure-Temperature Relationship in Gases

Lab 12 Pressure-Temperature Relationship in Gases Lab 12 Pressure-Temperature Relationship in Gases INTRODUCTION /PURPOSE/PLE LAB QUESTION Gases are made up of molecules that are in constant motion and exert pressure when they collide with the walls of

More information

Advantages / Disadvantages of semiconductor detectors

Advantages / Disadvantages of semiconductor detectors Advantages / Disadvantages of semiconductor detectors Semiconductor detectors have a high density (compared to gas detector) large energy loss in a short distance diffusion effect is smaller than in gas

More information

Physics for Scientists and Engineers 4th Edition 2017

Physics for Scientists and Engineers 4th Edition 2017 A Correlation and Narrative Summary of Physics for Scientists and Engineers 4th Edition 2017 To the AP Physics C: Electricity and Magnetism Course Description AP is a trademark registered and/or owned

More information

Never switch on the equipment without the assistants explicit authorization!

Never switch on the equipment without the assistants explicit authorization! Biot Savart s law 1 Objective The objective of this experiment is to verify Biot-Savart s law for certain geometries. Over the course of the preparation, the actual experiment and the writing of the report

More information

EE3901 A2001. Semiconductor Devices. Exam 1

EE3901 A2001. Semiconductor Devices. Exam 1 Name ECE Box # Problem Score Points 1 10 2 30 3 35 4 25 EE3901 A2001 Semiconductor Devices Exam 1 This is a closed book test! You are allowed one sheet (both sides) of notes. Note: Potentially useful reference

More information

Semiconductor Devices, Fall Gunnar Malm, Associate Professor Integrated Devices and Circuits, Kista Campus

Semiconductor Devices, Fall Gunnar Malm, Associate Professor Integrated Devices and Circuits, Kista Campus Semiconductor Devices, Fall 2014 Gunnar Malm, Associate Professor Integrated Devices and Circuits, Kista Campus gunta@kth.se, 08-790 4332 Semiconductor procesing at KTH Electrum Laboratory Stepper Lithography

More information

nmos IC Design Report Module: EEE 112

nmos IC Design Report Module: EEE 112 nmos IC Design Report Author: 1302509 Zhao Ruimin Module: EEE 112 Lecturer: Date: Dr.Zhao Ce Zhou June/5/2015 Abstract This lab intended to train the experimental skills of the layout designing of the

More information

Impurity Content of a Semiconductor Crystal

Impurity Content of a Semiconductor Crystal Impurity Content of a Semiconductor Crystal Experiment F1/3 Contents Impurity Content of a Semiconductor Crystal... 2 1 Aims... 2 Background... 3 Doping... 3 Crystal Growth... 4 The 4-point probe... 6

More information

MOS CAPACITOR AND MOSFET

MOS CAPACITOR AND MOSFET EE336 Semiconductor Devices 1 MOS CAPACITOR AND MOSFET Dr. Mohammed M. Farag Ideal MOS Capacitor Semiconductor Devices Physics and Technology Chapter 5 EE336 Semiconductor Devices 2 MOS Capacitor Structure

More information

Chem 481 Lecture Material 3/20/09

Chem 481 Lecture Material 3/20/09 Chem 481 Lecture Material 3/20/09 Radiation Detection and Measurement Semiconductor Detectors The electrons in a sample of silicon are each bound to specific silicon atoms (occupy the valence band). If

More information

X: The Hall Effect in Metals

X: The Hall Effect in Metals X: The all Effect in Metals I. References C. Kittel: Introduction to Solid State Physics, pp. 148-151. Ashcroft and Mermin: Solid state Physics, pp. 6-15. Dekker: Solid State Physics, pp. 301-302. Yarwood:

More information

Electric Field and Electric Potential (A)

Electric Field and Electric Potential (A) Pre-Lab Quiz / PHYS 224 Electric Field and Electric Potential (A) Your Name Lab Section 1. What do you investigate in this lab? 2. In a uniform electric field between two parallel plates, a potential probe

More information

Lab 4: The Classical Hall Effect

Lab 4: The Classical Hall Effect Lab 4: The Classical Hall Effect Background A particle with charge q moving with a velocity v in a uniform magnetic field B will experience a force F, F = q( v B ) (1) 1 Introduction Understanding the

More information

Hall effect in germanium

Hall effect in germanium Hall effect in germanium Principle The resistance and Hall voltage are measured on rectangular pieces of germanium as a function of the doping of the crystal, temperature and of magnetic field. From the

More information

Hall Effect Measurement in Germanium (Electrical Transport Option) Prof. Richard Averitt, UC San Diego

Hall Effect Measurement in Germanium (Electrical Transport Option) Prof. Richard Averitt, UC San Diego Hall Effect Measurement in Germanium (Electrical Transport Option) Prof. Richard Averitt, UC San Diego Description: The objective of this educational module is to measure the Hall effect germanium and

More information

Make sure the exam paper has 7 pages (including cover page) + 3 pages of data for reference

Make sure the exam paper has 7 pages (including cover page) + 3 pages of data for reference UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences Fall 2005 EE143 Midterm Exam #1 Family Name First name SID Signature Make sure the exam paper

More information

Introduction to Electrical Theory and DC Circuits

Introduction to Electrical Theory and DC Circuits Introduction to Electrical Theory and DC Circuits For Engineers of All Disciplines by James Doane, PhD, PE Contents 1.0 Course Overview... 4 2.0 Fundamental Concepts... 4 2.1 Electric Charges... 4 2.1.1

More information

Before we go to the topic of hole, we discuss this important topic. The effective mass m is defined as. 2 dk 2

Before we go to the topic of hole, we discuss this important topic. The effective mass m is defined as. 2 dk 2 Notes for Lecture 7 Holes, Electrons In the previous lecture, we learned how electrons move in response to an electric field to generate current. In this lecture, we will see why the hole is a natural

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 81 Name Date Partners Lab 5 - ELECTRON CHARGE-TO-MASS RATIO OBJECTIVES To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass ratio

More information

CSCB58:Computer Organization

CSCB58:Computer Organization CSC58:Computer Organization Instructor: rian Harrington brian.harrington@utsc.utoronto.ca * Original slides by Steve Engels Why take CSC58? To better understand computers! See what's going on "under the

More information

Introduction to Transistors. Semiconductors Diodes Transistors

Introduction to Transistors. Semiconductors Diodes Transistors Introduction to Transistors Semiconductors Diodes Transistors 1 Semiconductors Typical semiconductors, like silicon and germanium, have four valence electrons which form atomic bonds with neighboring atoms

More information

The e/m Ratio of the Electron

The e/m Ratio of the Electron OBJECTIVE The e/m Ratio of the Electron To study the behavior of a charged particle in the presence of a potential difference. To study the behavior of a charged particle moving in a magnetic field. To

More information

Simple circuits - 3 hr

Simple circuits - 3 hr Simple circuits - 3 hr Resistances in circuits Analogy of water flow and electric current An electrical circuit consists of a closed loop with a number of different elements through which electric current

More information

Practical 1P4 Energy Levels and Band Gaps

Practical 1P4 Energy Levels and Band Gaps Practical 1P4 Energy Levels and Band Gaps What you should learn from this practical Science This practical illustrates some of the points from the lecture course on Elementary Quantum Mechanics and Bonding

More information

Ion Implant Part 1. Saroj Kumar Patra, TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

Ion Implant Part 1. Saroj Kumar Patra, TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU ) 1 Ion Implant Part 1 Chapter 17: Semiconductor Manufacturing Technology by M. Quirk & J. Serda Spring Semester 2014 Saroj Kumar Patra,, Norwegian University of Science and Technology ( NTNU ) 2 Objectives

More information

Semiconductor Detectors

Semiconductor Detectors Semiconductor Detectors Summary of Last Lecture Band structure in Solids: Conduction band Conduction band thermal conductivity: E g > 5 ev Valence band Insulator Charge carrier in conductor: e - Charge

More information

2. In words, what is electrical current? 3. Try measuring the current at various points of the circuit using an ammeter.

2. In words, what is electrical current? 3. Try measuring the current at various points of the circuit using an ammeter. PS 12b Lab 1a Fun with Circuits Lab 1a Learning Goal: familiarize students with the concepts of current, voltage, and their measurement. Warm Up: A.) Given a light bulb, a battery, and single copper wire,

More information

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. MAGNETIC DEFLECTION OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. THEORY: Moving charges exert forces on one another that are not observed

More information

Practical 1P4 Energy Levels and Band Gaps

Practical 1P4 Energy Levels and Band Gaps Practical 1P4 Energy Levels and Band Gaps What you should learn from this practical Science This practical illustrates some of the points from the lecture course on Elementary Quantum Mechanics and Bonding

More information

Current Balance Warm Up

Current Balance Warm Up PHYSICS EXPEIMENTS 133 Current Balance-1 Current Balance Warm Up 1. Force between current-carrying wires First, let us assume only one wire exists,. Wire 1 has a length (where is "long") and carries a

More information

Physical structure of matter Band gap of germanium with Cobra3. Solid-state Physics, Plasma Physics. What you need:

Physical structure of matter Band gap of germanium with Cobra3. Solid-state Physics, Plasma Physics. What you need: Physical structure of matter Solid-state Physics, Plasma Physics Band gap of germanium with Cobra3 What you can learn about Semiconductor Band theory Forbidden band Intrinsic conduction Extrinsic conduction

More information

PHYSICS EXPERIMENTS 133. P (x 0,y 0 )

PHYSICS EXPERIMENTS 133. P (x 0,y 0 ) RvsT-1 Week 3: Recitation Electric field of a continuous charge distribution Q1. Find the electric field at point (x 0, y 0 ) due a thin rod (length L) of charge with uniform linear charge density and

More information

Electric Field PHYS 296

Electric Field PHYS 296 Electric Field PHYS 296 Your name Lab section PRE-LAB QUIZZES 1. What will we investigate in this lab? 2. In a uniform electric field between two parallel plates, a potential probe records the electric

More information

Lecture 2 Electrons and Holes in Semiconductors

Lecture 2 Electrons and Holes in Semiconductors EE 471: Transport Phenomena in Solid State Devices Spring 2018 Lecture 2 Electrons and Holes in Semiconductors Bryan Ackland Department of Electrical and Computer Engineering Stevens Institute of Technology

More information

Experiment 4. RC Circuits. Observe and qualitatively describe the charging and discharging (decay) of the voltage on a capacitor.

Experiment 4. RC Circuits. Observe and qualitatively describe the charging and discharging (decay) of the voltage on a capacitor. Experiment 4 RC Circuits 4.1 Objectives Observe and qualitatively describe the charging and discharging (decay) of the voltage on a capacitor. Graphically determine the time constant τ for the decay. 4.2

More information

Hall Coefficient of Germanium

Hall Coefficient of Germanium Sridhar Chandramouli 1 Hall Coefficient of Germanium Physics Department, The College of Wooster, Wooster, Ohio 691 April 9, 1999 This experiment experimentally measures the Hall coefficient of a Germanium

More information

Experiment 2 Electric Field Mapping

Experiment 2 Electric Field Mapping Experiment 2 Electric Field Mapping I hear and I forget. I see and I remember. I do and I understand Anonymous OBJECTIVE To visualize some electrostatic potentials and fields. THEORY Our goal is to explore

More information

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO 79 Name Date Partners OBJECTIVES OVERVIEW Lab 5 - ELECTRON CHARGE-TO-MASS RATIO To understand how electric and magnetic fields impact an electron beam To experimentally determine the electron charge-to-mass

More information

A semiconductor is an almost insulating material, in which by contamination (doping) positive or negative charge carriers can be introduced.

A semiconductor is an almost insulating material, in which by contamination (doping) positive or negative charge carriers can be introduced. Semiconductor A semiconductor is an almost insulating material, in which by contamination (doping) positive or negative charge carriers can be introduced. Page 2 Semiconductor materials Page 3 Energy levels

More information

EE 5211 Analog Integrated Circuit Design. Hua Tang Fall 2012

EE 5211 Analog Integrated Circuit Design. Hua Tang Fall 2012 EE 5211 Analog Integrated Circuit Design Hua Tang Fall 2012 Today s topic: 1. Introduction to Analog IC 2. IC Manufacturing (Chapter 2) Introduction What is Integrated Circuit (IC) vs discrete circuits?

More information

Revision : Thermodynamics

Revision : Thermodynamics Revision : Thermodynamics Formula sheet Formula sheet Formula sheet Thermodynamics key facts (1/9) Heat is an energy [measured in JJ] which flows from high to low temperature When two bodies are in thermal

More information

Engineering 2000 Chapter 8 Semiconductors. ENG2000: R.I. Hornsey Semi: 1

Engineering 2000 Chapter 8 Semiconductors. ENG2000: R.I. Hornsey Semi: 1 Engineering 2000 Chapter 8 Semiconductors ENG2000: R.I. Hornsey Semi: 1 Overview We need to know the electrical properties of Si To do this, we must also draw on some of the physical properties and we

More information

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5. HMS-5000 Manual Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K - Manual version: ver 5.01- www.ecopia21.co.kr - Table of contents - 1. Hardware Installation

More information

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. MAGNETIC DEFLECTION OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field. THEORY: Moving charges exert forces on one another that are not observed

More information

Session 5: Solid State Physics. Charge Mobility Drift Diffusion Recombination-Generation

Session 5: Solid State Physics. Charge Mobility Drift Diffusion Recombination-Generation Session 5: Solid State Physics Charge Mobility Drift Diffusion Recombination-Generation 1 Outline A B C D E F G H I J 2 Mobile Charge Carriers in Semiconductors Three primary types of carrier action occur

More information

B = 8 0 NI/[r (5) 3/2 ],

B = 8 0 NI/[r (5) 3/2 ], ELECTRON BEAM IN A MAGNETIC FIELD Introduction: A charged body moving relative to a magnetic field experiences a force which is perpendicular to both the velocity of the particle and to the magnetic field.

More information

Physics 2310 Lab #3 Driven Harmonic Oscillator

Physics 2310 Lab #3 Driven Harmonic Oscillator Physics 2310 Lab #3 Driven Harmonic Oscillator M. Pierce (adapted from a lab by the UCLA Physics & Astronomy Department) Objective: The objective of this experiment is to characterize the behavior of a

More information

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol PHY3901 PHY3905 Hall effect and semiconductors Laboratory protocol PHY3901 PHY3905 Hall effect and semiconductors Laboratory protocol Objectives Observe and qualitatively understand the phenomenon of transverse

More information

4. I-V characteristics of electric

4. I-V characteristics of electric KL 4. - characteristics of electric conductors 4.1 ntroduction f an electric conductor is connected to a voltage source with voltage a current is produced. We define resistance being the ratio of the voltage

More information

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB:

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB: SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB: John Lane, JD853@maristb.marist.edu Taylor Pancoast, JD573@maristb.marist.edu OVERVIEW OF LAB DESCRIPTION

More information

Physics (2) Laboratory manual

Physics (2) Laboratory manual PHYS 104 Laboratory Physics (2) Laboratory manual Dr. Chokri Belgacem, Dr. Yazid Delenda, Dr. Magdi Hasan Department of Physics, Faculty of Sciences and Arts at Yanbu, Taibah University - Yanbu Branch,

More information

PHYS 272 (Spring 2018): Introductory Physics: Fields Homeworks

PHYS 272 (Spring 2018): Introductory Physics: Fields Homeworks PHYS 272 (Spring 2018): Introductory Physics: Fields Homeworks Note: the 1st homework is simply signing the honor pledge (but still it is compulsory); the actual homework starts with #2. And, please sign

More information