Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques
|
|
- Joan Lindsey
- 5 years ago
- Views:
Transcription
1 Pesticides e-seminar Series - Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Date: 30 April 2009 Time : 10am Singapore Time For audio, please dial one of the phone numbers listed: International Telephone Number for Singapore: or Toll Free International Telephone Number for Hong Kong: Toll Free International Numbers: Australia New Zealand China Malaysia Indonesia Taiwan India* South Korea India (Backup)* Philippines Thailand* Vietnam * Phone line needs to be IDD enabled. Not accessible from Mobile Phones
2 Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques E-Seminar, April 30, 2009 Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA Page 2
3 MS Techniques Outline MS Analyzers Selection GC/MS deconvolution QQQ (MS/MS) LC/Q-TOF Summary Page 3
4 Analytical Instrumentations Chromatography (Separation the best friend of any detector) GC volatile and semi-volatile non-polar compounds LC polar or moderately polar or thermally labile compounds Detectors GC (element selective, FPD, NPD, ECD) high sensitivity, poor specificity LC (UV, FLD) general purpose, limited sensitivity MS SQ: high confidence from spectral confirmation, limited MDL QQQ: low detection limits of target compounds in dirty matrices (MRM) TOF/Q-TOF: always full spectrum and accurate mass for screening TOF-TOF, Q-Trap, and others (generally not for ROUTINE use) Page 4
5 Guiding Principles in MS Analyzer Selection The correct choice of analyzer depends on whether one is LOOKING for UNKNOWNS or whether one is CONFIRMING & MEASURING KNOWNS. The correct choice of analyzer depends on the COMPLEXITY of the MATRIX. Page 5
6 Basic Questions Which MS Solution Target analysis only? Scan or SIM or MS/MS Analysis of unknowns? Scan MS with Quad, IT or TOF How much chemical noise from the matrix? How much sample prep? Deconvolution or MS/MS MS/MS Page 6
7 General Workflow: Screen, Confirm and Quantify S C Q Representative Sample GC/MS (PTV) SIM/Scan for known and unknown Deconvolution Final Report S C (+backflush) Q QuEChERS Extraction 1 3 GC/QQQ MRM for known targets S C LC/QQQ MRM for known targets S C Q Q 1 3 LC/QTOF or TOF Full Spectrum for unknown compounds Exact Mass Database Search Clean-up 1 3 S Molecular Formula Generation Q Another injection for MS/MS (QQQ or QTOF) C C16 H19 N3 P Cl C15 H25 O P S Cl C18 H21 O P Cl Page 7
8 MS Techniques Outline MS Analyzers Selection GC/MS deconvolution QQQ (MS/MS) LC/Q-TOF Summary Page 8
9 TICs of Surface Water Extracts How many pesticides (drugs, allergens etc.) are in these samples and how long does it take you to confirm? Page 9
10 17 Surface Water TICs (Scan): Pesticide Analysis Using DRS with Pesticide Database (927 entries) Targets Found (not counting ISTD) CDFA* 37 Agilent DRS Same more False Positives 1 0 Processing Time ~8 hrs 32 min DRS: Deconvolution Reporting Software Saving 7.5 hours *CDFA is the California Department of Food and Agriculture Page 10
11 How Does Deconvolution Work? Page 11
12 Eliminate Ions Don t Fit the Criteria Ion grouping criteria: 1. Same RetTime at apex 2. Same peak width Page Extracted Ion Chromatograms (EIC)
13 Spectrum is Deconvoluted/Cleaned A component in AMDIS Related ions are grouped together as a component. Page 13
14 TIC of Spinach Extract More than 370 peaks found Deconvolution Page 14 Library Search
15 QEdit, p,p -DDT selected 5 ion overlay MSD ion AMDIS ion MSD & AMDIS areas & amounts 3 spectra x and A indicators Page 15
16 Pesticides in Red Wine - Fenpropathrin Found by AMDIS 250 ppb ppb Raw scan Not found 1 ppm MF = Deconvoluted MF = 783 Fenpropathrin 5 ppm Library entry MF = 877 Fenpropathrin Page 16
17 MS Techniques Outline MS Analyzers Selection GC/MS deconvolution QQQ (MS/MS) LC/Q-TOF Summary Page 17
18 Analyzers for Trace Target Compounds Who should use QQQ (MS/MS)? User doing Selected Ion Monitoring (SIM) for target compound analysis in traditional markets, needing additional sensitivity and selectivity with less sample prep, to meet more demanding analytical requirements. GC/QQQ MRM for known targets S LC/QQQ MRM for known targets S C C Q Q Page 18
19 Advantages of a QQQ as a Chromatographic Detector - Multiple Reaction Monitoring (MRM) Source Quad Mass Filter (Q1) Collision Cell Quad Mass Filter (Q3) Spectrum with background ions (from EI) Q1 lets only target ion 210 pass through 210 Collision cell breaks ion 210 apart Q3 monitors only characteristic fragments 158 and 191 from ion 210 for quant and qual no chemical background Page 19
20 Why MS/MS? Greater Selectivity Than SIM EI-SIM selectivity proportional to spectral resolution no selectivity against ions with same m/z interference analyte EI-MS/MS Precursor selectivity same as SIM High probability that at least one product ion will be a unique dissociation product of the precursor BUT not the interference Product 2 unit mass resolution Product 3 Product 1 interference Precursor Ion The precursor ion should NOT be used for ion ratios or quantitation since the interferences will be the same as the SIM ion Page 20
21 Consistent MS/MS Results, Regardless of Matrices Analysis of spiked p,p -DDE at 10 ppb (All injections = 1 µl) SIM - EIC (246) MRM (2 transitions) Apple Cabbage > 176.1, > x10 4 Ratio=23.5 Counts A c q u isitio n T im e (m in ) > 176.1, > x10 3 Ratio=22.9 Counts S/N = 448 S/N = 241 Ginseng A c q u is itio n T im e (m in ) > 176.1, > Counts x10 4 Ratio= S/N = 446 Orange > 176.1, > x10 3 Ratio= Counts Acquisition Time (min) S/N = Spinach A c q uisitio n T ime (min ) > 176.1, > x10 4 Ratio= Counts A c q u is itio n T im e (m in ) S/N = 260 AppNote: ; 175 pesticides Page 21
22 Carrot Extract - 1 µl with GC/QQQ is Much Better than 5 µl GC/Q GC/Q GC/QQQ 5 µl (Multi-mode Inlet) 1 µl Pesticide Cold SL Scan + DRS Cold SL SIM Hot SL (ppb) Diclobenil 0.38* Pentachlorobenzene 0.75* Trifluralin 2.3* Tefluthrin 0.53* 4,4'-Dichlorobenzophenone 1.2* Chlorpyrifos 24.7 o,p'-dde 3.7 p,p'-dde X X 240 o,p'-ddd 9 p,p'-ddd X o,p'-ddt X Sum = 45 p,p'-ddt X X 130 Fenazaquin X Not in Method * = Below Calibration Level Page 22
23 p,p -DDE in Carrot Extract (240 ppb) 5 µl GC/Q vs. 1 µl GC/QQQ 5 µl Cold SL Scan EIC S/N = 35 Same as left, after deconvolution 5 µl Cold SL SIM EIC S/N = µl Hot SL QQQ MRM > 176.1, > x10 5 Ratio=23.8 Counts S/N = Acquisition Time (min) Page 23
24 Why a GC/MS/MS System? Allows for the selective quantitation of target compounds in high chemical background samples Better S/N in complex matrices than can be achieved by single quadrupole scan or SIM approaches. Newer regulations in some markets specify analytical power commensurate with GC/MS/MS Page 24
25 The Limitations of Converting an LC/MS/MS to GC/MS/MS ESI, APCI and APPI - Atmospheric pressure sources Designed to separate ions from molecules before entering the vacuum manifold Higher m/z metal rods are typically temperature compensated for 100ºC operation (some only 50ºC) no problem since only ions enter the analyzer EI, PCI and NCI - Vacuum sources All neutral molecules (carrier gas, analytes and matrix) enter the vacuum manifold BEFORE ionization Most molecules are NOT ionized and must be pumped away High boiling molecules common to GC will contaminate all cooler surfaces Contamination causes loss of sensitivity Cool (< 100ºC) metal quadrupoles are easily contaminated under GC/MS Page 25
26 Why Heated Quartz Gold Quads? Higher temperature reduces potential for contamination 200 C max Virtually eliminates the need to clean quads Low coefficient for thermal expansion for quartz Stable structure during maintenance cycles (hot-cool-hot) for source or detector More stable tunes and methods over a longer period of time in real world sample environments Page 26
27 MS Technique Outline MS Analyzers Selection GC/MS deconvolution QQQ (MS/MS) LC/Q-TOF Summary Page 27
28 Agilent Q-TOF Fundamentals Two key concepts for TOF: 1. Exact Mass 2. Mass Error Collision cell Common with QQQ Ion optics Common with Q & QQQ Flight tube Common with TOF Ion Mirror Octopole 1 Quad Mass Filter (Q1) Octopole 2 Detector Lens 1 and 2 Collision Cell DC Quad Ion Pulser Rough Pump Turbo Turbo Turbo Turbo Page 28 September, 2008
29 Mass Analysis for TOF v = d/t E = ½ m v 2 = ½ m (d/t) 2 m = (2E/d 2 ) t 2 Energy (E) and Distance (d) are fixed The measured mass is proportional to the flight time (time-of-flight). Page 29
30 What does Exact Mass mean? amu Element Atomic Number Exact Mass H C N O C6H6Cl Lindane C10H12N2O6S Carbasulam C9H21O2PS Terbufos C13H21O3PS Iprobenfos C15H17N4Cl Myclobutanil C12H21N2O4P Diazoxon C11H20N4O3PS Epronaz C11H21N4O3P Pirimetaphos C16H20N2O Imazamethabenz The Key for getting useful TOF results is good mass accuracy. Uses accurate mass on TOF/Q-TOF to identify all of them. Page 30 September, 2008
31 Calculation of Error in Measured Mass (MH + ) of Reserpine Atom Mass of Atom # of Atoms Sum Hydrogen Carbon Nitrogen Oxygen Total Plus H Total Minus e Calculated = exact CH 3 O CH 3 (Measured - Calculated) Calculated X 1,000,000 = ppm ppm Error if the electron was not omitted! O CH 3 N H H O H O N CH 3 O O H CH 3 Reserpine (C 33 H 40 N 2 O 9 ) O O O CH 3 Page 31 September, 2008
32 TOF/Q-TOF Unlimited Number of Compound Screening 5556.D (Grape) MS1 Full Spectrum Molecular Feature Extractor found 510 compounds in the TIC. 15 out of 510 compounds had hits from EXACT MASS database search, i.e., these 15 matched entries in the database within 3 ppm mass accuracy. The three highlighted compounds were further confirmed by MS/MS. Page 32 September, 2008
33 Terbuconazole The compound name Terbuconazole came up in the MS1 mode search. Use formula results and MS/MS results to confirm the hit. Cl H 3 C CH 3 x Cpd 11:+ Scan ( min, 5 scans) 5556.d MS1 Full Spectrum C16H23ClN3O N N N CH 3 OH 1 0 x Cpd 11:+ Product Ion ( min) ( [z=1] -> **) 5556.d C4H6O MS/MS Full Spectrum C7H6Cl Counts vs. Mass-to-Charge (m/z) x Cpd 11:+ Scan ( min, 5 scans) 5556.d C16H23ClN3O Counts vs. Mass-to-Charge (m/z) Boxes represent theoretical isotope ratios Page 33
34 Screen Pesticides with LC-TOF/Q-TOF Accurate Mass provides added compound selectivity Higher resolution provides added interference selectivity Always full spectral data Unlimited number of compounds can be screened (search exact mass compound database for identification) Sensitivity is the same regardless of number of compounds screened* MS/MS (Q-TOF) assists compound confirmation *Triple quadrupole (QQQ) mass spectrometer can be more sensitive up to a limited number of compounds. That limit has not been definitively determined. Page 34
35 MS Technique Outline MS Analyzers Selection GC/MS deconvolution QQQ (MS/MS) LC/Q-TOF Summary Page 35
36 Summary GC/MS and Deconvolution to Screen, Confirm and Quantify QQQ for routine Targeted trace analysis in complex matrix MRM Sensitivity unsurpassed (up to a few hundred compounds) Complex matrix with less clean-up TOF/Q-TOF for Targeted and Unknown Screening Sensitive full scan analysis Searching exact mass database leads to identification Unlimited number of compounds Sensitivity is the same regardless of number of compounds screened Quantitative Accurate mass MS/MS for identification of fragments and structure elucidation (hotlink available to search on-line databases) Page 36
37 References Application Note : Replacing Multiple 50-Minute GC and GC- MS/SIM Analyses with One 15-Minute Full-Scan GC-MS Analysis for Nontargeted Pesticides Screening and >10x Productivity Gain Pesticide Brochure GC-QQQ Brochure Current Trends in Mass Spectrometry, pp 33-38, Nov (Supplement to LC/GC North America): Comprehensive Screening, Confirmation, and Quantification of Organic Pesticides in Foods by GC-MS and LC-MS The Applications Book, LC/GC Europe, pp 9-11, Dec. 2008: The Benefits of Incorporating GC/QQQ into Pesticide Analysis Methods Page 37
38 Thank you for your attention. Questions? Jan. in Amsterdam Page 38
39 Technology Agilent took the best technologies from their industry leading 597X Series GC/MSD: Heated monolithic gold plated quartz quadrupole Proven reliable high performance source design AUTOTUNE and the 6410A LC/QQQ: Linear acceleration enhanced Collision Cell Wide Mass-Bandwidth QQQ ion optics MassHunter software Page 39
40 Identify Dichlofenthion in MSD ChemStation -Red wine hidden 250 ppb No match 500 ppb No match 1 ppm MF = 630/670 Dichlofenthion Page 40
41 Identify Dichlofenthion in AMDIS hidden 250 ppb 250 ppb Raw scan No match 500 ppb MF = 82 Deconvoluted No match 1 ppm Library entry MF = 630/670 Dichlofenthion Page 41
42 Agilent Has the TOTAL Portfolio for Pesticide hidden Analysis G A S phase GC FPD/ECD GC/QQQ MRM (semi)-volatile or non-polar GC/Q DRS L I Q U I D phase LC UV, FLD LC/QQQ MRM Routine Analysis (moderate)-polar or thermally labile LC/Q TOF Q-TOF Exact Mass Database Search Identify Unknowns Page 42
Workflow Using Hyphenated Mass Spectrometry Techniques
Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques Chinkai (Kai) Meng, Ph.D. Senior Applications Chemist Wilmington, Delaware USA chin_meng@agilent.com com February 12, 2009 Page
More informationIntroducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies
Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies Page 1 Agilent GC/MS Portfolio Smallest footprint, single GC column 5975VL with 6850GC Industry leading
More informationHighly Sensitive and Rugged GC/MS/MS Tool
Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis Introduction
More informationAgilent s New 7000B Quadrupole GC/MS/MS:
Agilent s New 7000B Quadrupole GC/MS/MS: Evolving technology for higher performance tools Terry L. Sheehan, Ph.D. GC/MS/MS Product Manager Agilent Technologies Santa Clara, CA Page 1 Triple Quadrupole
More informationOverview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)
Quantitation and Identification of Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples using Advanced TripleTOF MS/MS Technology André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationTheory and Practical Consequences.
Theory and Practical Consequences. Number of hits depending on reachable mass accuracy 250 hits @ ±10 ppm 137 hits @ ±5 ppm 78 hits @ ±3 ppm 29 hits @ ±1 ppm 3 hits @ ±0.1 ppm 1 hit @ ± 0.05 ppm Intens.
More informationMaking Sense of Differences in LCMS Data: Integrated Tools
Making Sense of Differences in LCMS Data: Integrated Tools David A. Weil Agilent Technologies MassHunter Overview Page 1 March 2008 How Clean is our Water?... Page 2 Chemical Residue Analysis.... From
More informationMassHunter TOF/QTOF Users Meeting
MassHunter TOF/QTOF Users Meeting 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks
More informationAnalysis of Polar Metabolites using Mass Spectrometry
Analysis of Polar Metabolites using Mass Spectrometry TransMed Course: Basics in Clinical Proteomics and Metabolomics. Oct 10-19, 2012 dd.mm.yyyy Vidya Velagapudi, Ph.D, Adjunct Professor Head of the Metabolomics
More informationMulti-residue analysis of pesticides by GC-HRMS
An Executive Summary Multi-residue analysis of pesticides by GC-HRMS Dr. Hans Mol is senior scientist at RIKILT- Wageningen UR Introduction Regulatory authorities throughout the world set and enforce strict
More informationMulti-residue GC-MS analysis. Richard Fussell CSL York, UK
Multi-residue GC-MS analysis Richard Fussell CSL York, UK e-mail: r.fussell@csl.gov.uk Outline of Presentation Background Gas Chromatography Mass Spectrometry - Options Capabilities and Applications Summary
More informationPesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS
PesticideScreener Comprehensive Pesticide Screening and Quantitation Innovation with Integrity UHR-TOF MS The Challenge of Comprehensive Pesticide Residue Analysis The use of pesticides to reduce crop
More informationCerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs
Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs Application Note Author Harry Prest, Ph.D. Senior Chemist in GC-MS Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara,
More informationAgilent MassHunter Quantitative Data Analysis
Agilent MassHunter Quantitative Data Analysis Presenters: Howard Sanford Stephen Harnos MassHunter Quantitation: Batch and Method Setup Outliers, Data Review, Reporting 1 MassHunter Quantitative Analysis
More informationAn Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining
An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining Dave Weil, Ph.D. and Jim Lau, Ph.D. Typical Method Conditions: 1260 UHPLC
More informationOverview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada
LC-MS/MS Based Strategy for the Non-Targeted Screening of an Unlimited Number of Contaminants in Food Using the AB SCIEX TripleTOF 5600 System and Advanced Software Tools André Schreiber 1 and Yun Yun
More informationIdentifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application
Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application Food Safety, Environmental Authors Chin-Kai Meng and Bruce Quimby Agilent Technologies, Inc. 2850 Centerville
More informationMass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS
Mass Spectrometry Hyphenated Techniques GC-MS LC-MS and MS-MS Reasons for Using Chromatography with MS Mixture analysis by MS alone is difficult Fragmentation from ionization (EI or CI) Fragments from
More informationMassHunter Software Overview
MassHunter Software Overview 1 Qualitative Analysis Workflows Workflows in Qualitative Analysis allow the user to only see and work with the areas and dialog boxes they need for their specific tasks A
More informationImproved Detection of Food Contamination using GC/QQQ and GC/QTOF
Improved Detection of Food Contamination using GC/QQQ and GC/QTOF Philip L. Wylie, Ph.D. Sr. Applications Chemist for Food Safety Agilent Technologies December 1, 011 1 Some of the Food and Feed Contaminants
More informationThe Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications
The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications Doug Stevens Waters Corp. Introduction The range of GC/MS instrument types has expanded
More informationAll Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems
All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution
More informationAgilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012
1 Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012 Review: Technology for Accurate Mass Analysis: TOF LC/MS Mass measurements accurate to several
More informationDie Nadel im Heuhaufen
Die Nadel im Heuhaufen Workflow zur Identifizierung unerwarteter Komponenten in LC Q-Tof Daten Umwelt & Lebensmittel Seminar Tour Andreas Reimann Produktspezialist LC-MS Agilent Technologies Instrumentation
More informationIntroduction to GC/MS
Why Mass Spectrometry? Introduction to GC/MS A powerful analytical technique used to: 1.Identify unknown compounds 2. Quantify known materials down to trace levels 3. Elucidate the structure of molecules
More informationAgilent s LC/MS Portfolio and Applications Examples
Agilent s LC/MS Portfolio and Applications Examples Michael Scott LC/MS Product Specialist Agilent Technologies March 2013 For Research Use Only. Not for use in diagnostic procedures. Agilent 6000 Series
More informationTypes of Analyzers: Quadrupole: mass filter -part1
16 Types of Analyzers: Sector or double focusing: magnetic and electric Time-of-flight (TOF) Quadrupole (mass filter) Linear ion trap Quadrupole Ion Trap (3D trap) FTICR fourier transform ion cyclotron
More informationAutomated and accurate component detection using reference mass spectra
TECHNICAL NOTE 72703 Automated and accurate component detection using reference mass spectra Authors Barbara van Cann 1 and Amit Gujar 2 1 Thermo Fisher Scientific, Breda, NL 2 Thermo Fisher Scientific,
More informationAnalyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.
Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments Application Environmental Authors Jim Lau, Chin-Kai Meng, and Jennifer Gushue Agilent Technologies, Inc. 285 Centerville
More informationIntroduction to LC-MS
Wednesday April 5, 2017 10am Introduction to LC-MS Amy Patton, MS Laboratory Manager, Pinpoint Testing, LLC Little Rock, AR DESCRIPTION: Amy Patton, laboratory manager for Pinpoint Testing, will begin
More informationScreening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting
Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting Application Note Authors Angela Smith Henry and Bruce Quimby Agilent
More informationThe new Water Screening PCDL
The new Water Screening PCDL Content and integration in suspect and non-target screening Dr. Thomas Glauner Senior LC/MS Applications Scientist EMEA Market Development Team 1 Accurate mass screening and
More informationUseful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted
Useful Sensitivity for Improved Environmental Analyses Page 1 Definitions Sensitivity Analytical definition: slope of the plot of amount of analyte (x-axis) versus signal response (y-axis) Commonly used
More informationAgilent ESI and APCI sources: for polar to non-polar compounds
1 Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent ESI and APCI sources: for polar to non-polar compounds Nebulizer Pressure Corona current Nebulizer Pressure Vaporizer Vcap Vcap Drying Gas
More informationA Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry O. Scheibner, 1 P. van Baar, 2 F. Wode, 2 U. Dünnbier, 2 K. Akervik, 3 J. Humphries, 3 M. Bromirski 1
More informationAgilent All Ions MS/MS
Agilent All Ions MS/MS Workflow Overview A Determine fragment ions for LC/MS Quant method B Develop final Quant method Develop LC/MS Qualitative Analysis method Process data with Find by Formula Build
More informationA Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry
A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry Olaf Scheibner, 1 Patrizia van Baar, 2 Florian Wode, 2 Uwe Dünnbier, 2 Kristi Akervik, 3 Jamie Humphrie,
More informationImplementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis
An Executive Summary Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis The Exactive GC Orbitrap MS system can offer the specificity and sensitivity missing from
More informationComprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods
Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods Application Note Food Safety Authors Fadwa Al-Taher, Rima Juskelis, Yang Chen, Jack Cappozzo Institute for Food
More informationFinnigan LCQ Advantage MAX
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Finnigan LCQ Advantage MAX The Finnigan LCQ Advantage MAX ion trap mass spectrometer
More informationLC-MS Based Metabolomics
LC-MS Based Metabolomics Analysing the METABOLOME 1. Metabolite Extraction 2. Metabolite detection (with or without separation) 3. Data analysis Metabolite Detection GC-MS: Naturally volatile or made volatile
More informationIdentifying Disinfection Byproducts in Treated Water
Identifying Disinfection Byproducts in Treated Water Jonathan D. Byer, LEC Corporation; Saint Joseph, Michigan USA Susan D. Richardson, University of South Carolina; Columbia, South Carolina USA 1. Introduction
More informationDate ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY
Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY In practice, target analysis approach (analysing 1-4 of GC
More informationBenefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer
Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer Purchasing a mass spectrometer (MS) is an important investment for a laboratory. When considering instrument platforms, selection
More informationAgilent G3212 GC-APCI Source
Agilent G3212 GC-APCI Source Quick Start Guide Where to find information 2 Getting Started 3 Step 1. Start the Data Acquisition program for the GC and the Q-TOF 3 Step 2. Prepare the GC and Q-TOF for data
More informationAgilent 6400 Series Triple Quadrupole LC/MS/MS Users Session
Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session QQQ Method Development and Optimization MassHunter Quant: Method setup Peak detection optimization Quant troubleshooting David Presser Application
More informationAB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences
AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor
More informationSEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW
SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW Paula Hong, John Van Antwerp, and Patricia McConville Waters Corporation, Milford, MA, USA Historically UV detection has been
More informationTraining Courses. Chromatography training from the Crawford Scientific experts
Training Courses Chromatography training from the Crawford Scientific experts HPLC Fundamentals This one-day course introduces the fundamentally important concepts associated with HPLC analysis including
More informationSIFT-MS. technology overview
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY technology overview contents 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why three reagent ions? c. How does SIFT-MS
More informationAnalysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software
Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software NEMC, Washington D.C. August 6 th 2012 Nicola Watson Environmental Specialist Markes International
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationApplying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis
PO-CON1768E Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide ASMS 2017 TP-194 David Baker 1, Christopher Titman 1, Neil Loftus 1, Jonathan Horner
More informationTomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories
APPLICATION NOTE 65200 Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories Authors Neloni Wijeratne, Claudia Martins, Mary
More informationAnalysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401
Gas Chromatograph Mass Spectrometer No. GCMS-1401 Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS Introduction Development of methods for analysis of drugs of abuse has become a high
More informationConstruction and Use of API Single- Quadrupole MS Spectral Libraries.
Paul Zavitsanos Product Marketing Manager September 11, 2003 Construction and Use of API Single- Quadrupole MS Spectral Libraries. Time: 11:00 a.m. EDT Telephone Number: 888-840-7687 International Number:
More informationSIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS a. Why chemical ionization? b. Why multiple reagent
More informationIdentification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS
Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7B Triple Quadrupole GC/MS Application Note Authors Dale R. Walker and Fred Feyerherm Agilent Technologies, Inc.
More informationAgilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology
Agilent s New 8800 ICP-QQQ Transforming ICP-MS Technology 1 8800 ICP-QQQ Key Product Hardware High matrix introduction (HMI) technology Dual conical Extraction and Omega lens focuses ions across the mass
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationSelf Cleaning Ion Source and other Innovations in Mass Spectrometry. Kirk Lokits (GCMS Applications Chemist) Blacksburg, VA February 2 nd, 2017
Self Cleaning Ion Source and other Innovations in Mass Spectrometry Kirk Lokits (GCMS Applications Chemist) Blacksburg, VA February 2 nd, 2017 1 Jet Clean! Outcome JetClean self-cleaning ion source technology
More informationCerno Application Note Extending the Limits of Mass Spectrometry
Confident Compound Identification with High Mass Accuracy and Elemental Composition Specific NIST Library Search Identification of unknown compounds by unit mass resolution GC-MS systems essentially relies
More informationEGASUS. 4D GCxGC TOFMS. Delivering the Right Results
P EGAU 4D GCxGC TFM Delivering the Right Results LEC s P EGAU 4D GCxGC-TFM The Ultimate Analytical Instrument Pioneering GCxGC technology, combined with the Pegasus TFM and ChromaTF software provides today
More informationQuantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays
: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays Mark Wrona, Jayne Kirk, and Yun Alelyunas Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Ability
More informationTANDEM MASS SPECTROSCOPY
TANDEM MASS SPECTROSCOPY 1 MASS SPECTROMETER TYPES OF MASS SPECTROMETER PRINCIPLE TANDEM MASS SPECTROMETER INSTRUMENTATION QUADRAPOLE MASS ANALYZER TRIPLE QUADRAPOLE MASS ANALYZER TIME OF FLIGHT MASS ANALYSER
More informationTrim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ
Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1 Agenda Pesticide analysis trends Targeted
More informationKey Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery
Metabolite Stability Screening and Hotspot Metabolite Identification by Combining High-Resolution, Accurate-Mass Nonselective and Selective Fragmentation Tim Stratton, Caroline Ding, Yingying Huang, Dan
More informationImpurities Sources, Detection and Measurement HPLC-MS Analyses. Dr Courtney Milner Chemical Analysis
Impurities Sources, Detection and Measurement HPLC-MS Analyses Dr Courtney Milner Chemical Analysis Chemical Analysis Integrated Analytical Resource (Physical, Chemical and Microbiological) that has facilities
More informationTargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
TargetScreener A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS TargetScreener Get the Complete Picture Forensic laboratories are frequently required to perform
More informationApplication Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors
Trace-Level Analysis of Melamine in Milk Products on Agilent 789A/5975C GC/MSD Using a ew Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application ote Gas Chromatography/Mass Spectrometry/Food
More informationWADA Technical Document TD2003IDCR
IDENTIFICATION CRITERIA FOR QUALITATIVE ASSAYS INCORPORATING CHROMATOGRAPHY AND MASS SPECTROMETRY The appropriate analytical characteristics must be documented for a particular assay. The Laboratory must
More informationAgilent Technologies LCMS Portfolio
Agilent Technologies LCMS Portfolio Hardware and Software Solutions for the Most Challenging Applications Jean-Francois Roy MS Product Specialist Agilent Technologies 1 Raising the Standard in UHPLC Highest
More informationTIME OF FLIGHT GC/MSTOF
A New Concept of TOF-MS for the Latest Generation GC Techniques When productivity is the name of the game, MASTER TOF-MS is the answer Productivity has become of vital importance in most modern laboratories.
More informationUltra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) tandem mass spectrometry
PO-CON18E Ultra-fast screening of pesticides in foods and agricultural products with desorption corona beam ionization (DCBI) ASMS 21 TP 3 Jing Dong, Satoshi Yamaki, Yuki Hashi, Naoki Hamada Shimadzu China,
More informationAgilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1
Agilent 6400 Series Triple Quadrupole Users Workshop 1 Agilent 6400 Series Triple Quadrupole Users Workshop QQQ Method Development and Optimization MassHunter Quantitation: Batch and Method setup QC s,
More informationAnalysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF
Analysis of Biomarkers in Crude Oil Using the Agilent 7 GC/Q-TOF Application Note Petrochemical and Environmental Authors Frank David Research Institute for Chromatography, Kennedypark 6, B-85 Kortrijk,
More informationScreening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?
Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality? Laure Joly & Vincent Hanot WIV-ISP, Juliette Wytsmanstraat 14, 15 Brussel The passengers pesticides are requested......
More informationThermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis
Thermo Scientific Pesticide Explorer Collection Start-to-finish workflows for pesticide analysis Comprehensive Pesticide Analysis Solutions Pesticide Explorer Collection Selection table Lab Profile Routine
More informationIncreasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer
Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer Olaf Scheibner and Maciej Bromirski Thermo Fisher Scientific, Bremen, Germany Overview Purpose: Improve the performance
More informationUsing UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals
Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Adulteration in Dietary Supplements and Botanicals Application Note Food Testing & Agriculture Authors James Neal-Kababick
More informationDetermination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS
Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS Application note Semiconductor Authors Junichi Takahashi Agilent Technologies, Japan Introduction
More informationThe Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER
The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER THE AGILENT 6545 Q-TOF LC/MS SYSTEM FASTER ANSWERS BETTER MEASUREMENTS EASIER HIGH PERFORMANCE RESULTS The new 6545 Q-TOF
More informationAnalysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic
Analysis of pesticide residues using various GC/MS systems Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic OUTLINE Czech Agriculture and Food Inspection Authority (CAFIA)
More informationDe Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.
De Novo Metabolite Chemical Structure Determination Paul R. West Ph.D. Stemina Biomarker Discovery, Inc. As a part of non targeted metabolomic analysis, when peaks in the mass spectra are thought to be
More informationRapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS
Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS Application Note Forensic Toxicology Authors Martin Josefsson, and Markus Roman National Board of Forensic Medicine Linköping,
More informationNew Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses
New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller
More informationAnalysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS
PO-CONE Analysis of Pesticides in Baby Foods Using a Pittcon 01 -P Laura Chambers, Richard Whitney, Ph.D., Nicole M. Lock, Zhuangzhi Max Wang, Ph.D., Clifford M. Taylor; Shimadzu Scientific Instruments,
More informationAgilent 5977A Series GC/MSD System
Agilent 5977A Series GC/MSD System Data Sheet 5977A GC/MSD Overview The Agilent 5977A Series GC/MSD builds on a 45-year tradition of leadership and innovation, bringing together the technologies of the
More informationNew Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology
New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology Gas Chromatography/Mass Spectrometry Author Harry Prest 1601 California Avenue
More informationQuadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365
Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world s fastest
More informationProfiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry
Supporting Information for: Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid Chromatography-Tandem Mass Spectrometry Ramin Vismeh a,b, Fachuang Lu c,d, Shishir
More informationAgilent Technologies at TIAFT 2013
Agilent Technologies at TIAFT 2013 Agilent Technologies GC/MS portfolio for the growing challenge of designer drugs analysis Juan Aybar Gas Chromatography Marketing Jaume Morales MS Product Specialist
More informationDetermination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry
PO-CON1619E Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry Pittcon 2016 480-25 Yan Wang, Feifei Tian, Yueqi Li, Guixiang Yang, Taohong
More informationLC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode
LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode Application Note Authors Siji Joseph Agilent Technologies India Pvt. Ltd.
More informationCerno Application Note Extending the Limits of Mass Spectrometry
June Cerno Application Note Extending the Limits of Mass Spectrometry Accurate Mass Compound Identification with Single Quadrupole GC/MS Yongdong Wang I and Harry Prest II Single Quad GC/MS instruments
More informationGAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions
GAS CHROMATOGRAPHY MASS SPECTROMETRY Pre-Lab Questions Questions to be answered before doing the experiment. The answers are due at the beginning of each experiment without exception (the questions are
More informationfor the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York
Mass Spectrometry for the Novice John Greaves and John Roboz (^>, yc**' CRC Press J Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa business
More informationmicrotof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF
microtof-q III The bench-mark in accurate mass LC-MS/MS Innovation with Integrity ESI-Qq-TOF The Advantage of Confidence in Routine The microtof-q range is widely acknowledged in setting standards in performance
More informationDetermination of EU-Banned Disperse Dyes by LC/MSD TOF Application
Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application Environmental Authors Yanyan Fang Agilent Technologies, Inc. 412 Ying Lun Road Pu Dong, Shanghai 200131 China Ping Li Agilent Technologies,
More informationThermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer
IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Scientific LTQ Orbitrap Velos
More information